21

Sinterização de misturas de pós de ligas de ferro para aplicações automotivas

NEVES, MAURICIO D.M. das 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:51:15Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:06:05Z (GMT). No. of bitstreams: 1 11259.pdf: 8455233 bytes, checksum: c710358f0ad3ff6d959e43d6d7c72aad (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
22

Avaliacao e caracterizacao da liga de niquel tipo 600 apos processos de soldagem por fusao TIG, arco plasma e laser

CALVO, WILSON A.P. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:41:06Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:09:09Z (GMT). No. of bitstreams: 1 04673.pdf: 4338286 bytes, checksum: 9b40b59ddc2764691461410ae0194329 (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
23

Comparação entre soldagem de chapas finas de tântalo e monel 400 com laser pulsado de Nd:YAG e com laser contínuo de fibra / Comparison between welding of thin sheets of Tantalum and Monel 400 with pulsed Nd:YAG laser and continuous fiber laser

MAXIMO, ARTHUR 07 October 2015 (has links)
Submitted by Maria Eneide de Souza Araujo (mearaujo@ipen.br) on 2015-10-07T12:39:18Z No. of bitstreams: 0 / Made available in DSpace on 2015-10-07T12:39:18Z (GMT). No. of bitstreams: 0 / Dissertação (Mestrado em Tecnologia Nuclear) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
24

Avaliação microestrutural e mecânica da Incoloy® 945 após tratamentos térmicos / Microstructural and mechanical evaluation of Incoloy® 945 after heats treatment

MARTINS, IGOR C.P. 17 December 2015 (has links)
Submitted by Claudinei Pracidelli (cpracide@ipen.br) on 2015-12-17T09:09:06Z No. of bitstreams: 0 / Made available in DSpace on 2015-12-17T09:09:06Z (GMT). No. of bitstreams: 0 / Dissertação (Mestrado em Tecnologia Nuclear) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
25

Investigacao da tensao residual na soldagem laser entre o aco carbono AISI 1010 e o aco inoxidavel AISI 304 / Investigation of residual stress in laser welding between carbon steel AISI 1010 and stainless steel AISI 304

MIRIM, DENILSON de C. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:28:54Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:57:01Z (GMT). No. of bitstreams: 0 / Um dos mais críticos problemas encontrados na união de materiais distintos é a formação de tensões residuais, que ocorre principalmente pelo fato desses materiais possuírem coeficientes de expansão térmica e condutividades térmicas diferentes. Neste trabalho foi estudada a técnica de soldagem laser entre o aço carbono AISI 1010 e o aço inoxidável AISI 304. Os materiais foram unidos por solda autógena de topo com um laser de Nd:YAG contínuo. O principal objetivo do estudo foi a identificação da influência dos parâmetros de soldagem, pela análise das tensões residuais na zona termicamente afetada (ZTA). Foi executado um planejamento fatorial de três fatores a dois níveis com uma réplica, em que foram variadas a potência, a velocidade de soldagem e a posição focal do feixe laser. Na superfície da amostra foram realizadas medidas de tensão residual pela técnica de difração de raios X, para estudar sua variação em função dos parâmetros investigados. O método do furo cego foi também utilizado para avaliar a tensão residual ao longo da profundidade das amostras até a profundidade de 1 mm. Além das medidas de tensão residual, os cordões de solda foram avaliados por microscopia óptica e eletrônica de varredura (MEV), que tiveram como objetivos determinar a geometria do cordão e mudanças na microestrutura, também foram feitas medidas de microdureza Vickers para se avaliar a extensão da ZTA. Para se avaliar as propriedades mecânicas da união foram realizados ensaios de tração e fadiga. O software MINITAB 15 foi utilizado para a análise das tensões residuais nas diferentes profundidades da ZTA obtidas pelo método do furo cego. Foi utilizada também a regressão estatística baseada nas diferentes influências da entrada e combinação dos fatores na tensão residual geradas nessa união. Os resultados indicam que o desenvolvimento de modelos pode prever as respostas satisfatoriamente e fornecer aos usuários um guia para definir os melhores parâmetros de união. / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
26

Sinterização de misturas de pós de ligas de ferro para aplicações automotivas

NEVES, MAURICIO D.M. das 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:51:15Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:06:05Z (GMT). No. of bitstreams: 1 11259.pdf: 8455233 bytes, checksum: c710358f0ad3ff6d959e43d6d7c72aad (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
27

Avaliacao e caracterizacao da liga de niquel tipo 600 apos processos de soldagem por fusao TIG, arco plasma e laser

CALVO, WILSON A.P. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:41:06Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:09:09Z (GMT). No. of bitstreams: 1 04673.pdf: 4338286 bytes, checksum: 9b40b59ddc2764691461410ae0194329 (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
28

Comparação entre soldagem de chapas finas de tântalo e monel 400 com laser pulsado de Nd:YAG e com laser contínuo de fibra / Comparison between welding of thin sheets of Tantalum and Monel 400 with pulsed Nd:YAG laser and continuous fiber laser

MAXIMO, ARTHUR 07 October 2015 (has links)
Submitted by Maria Eneide de Souza Araujo (mearaujo@ipen.br) on 2015-10-07T12:39:18Z No. of bitstreams: 0 / Made available in DSpace on 2015-10-07T12:39:18Z (GMT). No. of bitstreams: 0 / Neste trabalho foram realizados experimentos de soldagem de chapas de Tântalo e Monel 400 com 100 m de espessura. Foram realizadas soldas em um laser de Nd:YAG operando em modo pulsado e em um Laser de Fibra operando em modo contínuo. Em seguida a microestrutura das amostras foram analisadas através de microscopia ótica e foram realizados ensaio de microdureza Vickers. As amostras que apresentaram melhores resultados foram submetidas a ensaios de tração e a ensaios de corrosão. Após análise dos resultados observou-se que a soldagem a laser apresenta muitos benefícios em relação a outros processos convencionais para chapas finas. A soldagem no modo pulsado apresentou maior relação de aspecto se comparado a soldagem em modo contínuo. A soldagem em modo contínuo apresentou uma velocidade de soldagem muito superior ao modo pulsado. Os resultados indicaram que a soldagem no modo pulsado apresenta maior aplicabilidade para chapas finas, devido à necessidade um controle preciso sobre a intensidade aplicada. / Dissertação (Mestrado em Tecnologia Nuclear) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
29

Avaliação microestrutural e mecânica da Incoloy® 945 após tratamentos térmicos / Microstructural and mechanical evaluation of Incoloy® 945 after heats treatment

MARTINS, IGOR C.P. 17 December 2015 (has links)
Submitted by Claudinei Pracidelli (cpracide@ipen.br) on 2015-12-17T09:09:06Z No. of bitstreams: 0 / Made available in DSpace on 2015-12-17T09:09:06Z (GMT). No. of bitstreams: 0 / Superligas de níquel são materiais mundialmente empregados nas áreas de petróleo e gás natural, aeroespacial e nuclear. A Incoloy® 945 uma liga desenvolvida em meados dos anos 2000, para ser uma liga hibrida entre a Inconel® 718 e Incoloy® 925, concebendo uma liga com propriedades mecânicas e anticorrosivas capaz de suportar as mais adversas operações de serviço. Neste trabalho foram determinadas algumas características mecânicas do material, após laminação a frio, seguindo duas diferentes rotas de tratamento térmico. Foram realizados testes de dureza Vickers e tração, onde mostrou que a rota experimental criada no IPEN (por intermédio da análise por calorimetria exploratória diferencial), tem a mesma resistência mecânica do que a rota comercialmente usada, contudo possui uma maior ductilidade. O material demonstra uma excepcional união resistência mecânica e ductilidade, podendo ser empregada no uso de tubulações e válvulas de alta complexidade de manufatura, para a exploração das camadas do pré-sal. / Dissertação (Mestrado em Tecnologia Nuclear) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
30

Evaluation of mechanical and fluoride ion release properties of a resin based restorative material, “Cention”

Hulsart, Line, Hongseethong, Chawanrat January 2022 (has links)
Background: A new permanent dental restorative material, Cention Forte, have recently been introduced. The manufacturer claims that this material has higher compressive strength than glass ionomer as well as positive ion release properties. Aim: To evaluate compressive strength, hardness and fluoride ion release properties of a new resin based dental restauration material, Cention Forte, in comparison with frequently used dental restoration materials.  Methods: Comparisons among Ceram.X Spectra ST (resin composite), GC Fuji II LC (glass ionomer) and Cention Forte (alkasite) were performed. Compression strength, Vickers hardness test and cumulative fluoride ion release for 2 days, 7 days in a pH4 water solution were tested. Results: Resin composites and Cention Forte showed no significant differences in compression strength, while glass ionomers showed a lower compression strength. The Vickers hardness test presented no significant difference between Cention Forte and the other two materials. Significant differences were found among the three materials in fluoride ion release. Resin composites released least amount of fluoride ions compared to Cention Forte and glass ionomer. After 2 days, Cention Forte release less fluoride than glass ionomer, but no differences in fluoride concentration after 7 days between these two materials.  Conclusions: Cention Forte showed equivalent mechanical properties to composite resin and comparable fluoride release property to glass ionomers.