• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 33
  • Tagged with
  • 33
  • 33
  • 30
  • 24
  • 18
  • 18
  • 12
  • 9
  • 9
  • 9
  • 9
  • 9
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Ovário-histerectomia minilaparoscópica em gatas hígidas

Lawall, Thaíse January 2015 (has links)
A ovário-histerectomia (OVH) é um procedimento cirúrgico realizado de maneira rotineira na clínica de pequenos animais, com objetivo terapêutico ou de promover a esterilização reprodutiva nas fêmeas. Muitas abordagens pela técnica convencional aberta já foram descritas e com viabilidade comprovada. No segmento da cirurgia de invasão mínima dentro da Medicina Veterinária, diversos métodos vêm sendo propostos variando entre si em relação ao posicionamento, quantidade e tamanho dos trocartes e método de hemostasia. Assim sendo, o objetivo deste estudo foi avaliar e descrever a viabilidade de realização da OVH em felinas com até 5 kg de peso corporal através de abordagem minilaparoscópica com uso de eltrocoagulação bipolar como método hemostático. A minilaparoscopia (MINI) não é uma modalidade recente na cirurgia laparoscópica humana. Considerada a evolução mais sofisticada da cirurgia laparoscopia, a MINI apresenta muitos outros benefícios além do estético; visto que a lesão relacionada ao dano cirúrgico não se resume as somas das incisões realizadas. A técnica reina pela delicadeza e precisão dos movimentos, sem perda da triangulação, essencial ao padrão laparoscópico. Foram avaliados os procedimentos de 15 felinas quanto à viabilidade e dificuldades do acesso minilaparoscópico, uso do cautério bipolar, o tamanho das incisões e a necessidade de ampliá-las, complicações trans e pós-operatórias assim como a dor demonstrada por esses pacientes. A avaliação da dor foi feita através de tabela específica para espécie felina com diretrizes estabelecidas e confiabilidade comprovada, auxiliada a outras duas tabelas de avaliação da dor. A conversão de minilaparoscopia à cirurgia aberta foi necessária em um dos quinze pacientes operados nesse estudo. Conclui-se que a realização da técnica de OVH por abordagem minilaparoscópica em gatas é factível. / Ovariohysterectomy (OHE) is a surgical procedure routinely performed in small animals practice, with therapeutic purpose or to promote reproductive sterilization in females. Numerous approaches have been described using conventional open technique and had their viability proven. In the segment of minimally invasive surgery in the Veterinary Medicine, several methods have been proposed, differing from each other in position, number and size of trocars and hemostasis method used. Thus, the goal of this study was to evaluate and describe the practicability of performing OHE in cats with up to 5 kg of body weight through minilaparoscopic approach, using bipolar eltrocoagulation as hemostatic method. The minilaparoscopy (MINI) is not a new modality in human laparoscopic surgery. Considered the most sophisticated evolution of laparoscopic surgery, the MINI has many other benefits beyond the aesthetic; since the injury caused by the damage of surgery is not just the sum of the incisions. The technique stands out for the delicacy and accuracy of the movement without loss of triangulation, essential for the laparoscopic model. The procedures of 15 female cats were evaluated for the viability and difficulties of minilaparoscopic approach, use of bipolar cautery, incision size and the need to enlarge it, trans and postoperative complications and pain demonstrated in these patients. Pain assessment was done through specific table for feline species with established guidelines and proven reliability, helped by other two pain assessment tables. The conversion from minilaparoscopy to open surgery was required in one of the fifteen patients operated on in this study. Therefore, the implementation minilaparoscopic approach for OHE technique is feasible in cats.
32

Videolaparoscopia flexível por acesso perianal em equinos / Flexible endoscopic perianal access videolaparoscopy in abdominal exploration of equines

Rocha, Andre Luiz de Araujo January 2013 (has links)
A técnica de videolaparoscopia exploratória da cavidade abdominal utilizada atualmente em equinos implica em uma série de dificuldades. Há necessidade do acesso cirúrgico bilateral da cavidade abdominal ou anestesia geral para acesso ventral com a finalidade de obter uma avaliação adequada das vísceras e, consequentemente, um diagnóstico mais preciso. Esse procedimento prolonga o tempo e aumenta os riscos de complicações transoperatórias e pós-cirúrgicas. Apesar de ser uma técnica bem estabelecida com situações em que as vantagens de sua utilização são evidentes, alguns fatores ainda limitam sua difusão, entre eles podemos destacar: o custo do equipamento que limita a utilização fora de Universidades, Centros de Pesquisas ou clínicas particulares especializadas em cirurgias veterinárias. Com o objetivo de minimizar os aspectos negativos dessa técnica e viabilizar seu uso na rotina clínica e cirúrgica de equinos, surgiu a ideia de buscar uma nova via de acesso à cavidade abdominal e utilizando o videocolonoscópio, equipamento de menor custo. No presente estudo, foi analisado o uso do endoscópio flexível na exploração abdominal de equinos machos castrados e fêmeas pelo acesso perianal. A técnica foi avaliada quanto à viabilidade de permitir ou não o acesso à cavidade e identificação das vísceras abdominais em equinos. Além disso, buscou-se verificar se o endoscópio flexível permite a obtenção de amostras de tecido hepático para avaliação histológica. Os animais foram, alimentados, desverminados e avaliados diariamente por meio de exame clínico geral durante o período do experimento. Colheitas de amostras de sangue para hemograma e dosagem de fibrinogênio foram realizadas antes e após o procedimento cirurgico para posterior analise. Todos os cuidados de rotina em relação à antissepsia cirúrgica foram devidamente tomados e os animais submetidos a protocolo de sedação e analgesia. Os procedimentos de pós-operatório como terapia analgésica, anti-inflamatória, inspeção e higienização diária do local de incisão foram prestados. O procedimento cirúrgico teve início com incisão na região perianal laterodorsal direita entre o ânus e o musculo semimembranoso utilizando bisturi e tesoura, seguida de divulsão romba com o dedo ao longo da parede retal até alcançar uma profundidade aproximada de 10 cm, momento no qual foi introduzida cânula metálica com 56 cm de comprimento e 16 mm de diâmetro (Ø). Por meio desta cânula foi introduzido o endoscópio flexível (videocolonoscópio), sendo o restante da introdução da cânula acompanhada por visualização indireta em monitor. A cânula foi forçada lentamente até atingir a cavidade peritoneal, momento a partir do qual foi realizada exploração da cavidade abdominal. As vísceras observadas foram anotadas em ficha especialmente desenvolvida para esta finalidade. Como parte da avaliação hepática foi realizada biópsia e o material obtido analisado no setor de patologia da Faculdade de Veterinária da UFRGS. Após dez dias de pós-operatório, quando em plenas condições de saúde, os equinos receberam alta. Os resultados permitem inferir que, o uso do endoscópio flexível na identificação das vísceras abdominais por meio de laparoscopia perianal é viável na rotina clínica e cirúrgica de equinos e possibilita obter amostras teciduais para avaliação histológica. No entanto, o emprego da técnica exige o treinamento da equipe cirúrgica, principalmente do cirurgião, bom planejamento e um diagnóstico pré-operatório incompleto que necessite complementação diagnóstica. / The technique of exploratory laparoscopy abdominal cavity used currently in horses involves a series of difficulties. There is need for bilateral abdominal cavity surgical access or general anesthesia for ventral access for the purpose of obtaining an adequate assessment of the viscera and, consequently, a more accurate diagnosis. This procedure extends and increases the risks of post-surgical complications and transoperatórias. Despite being a well-established technique in situations where the advantages of its use are evident, some factors still limit its spread, some of them are: the cost of equipment that limits the use out of universities, research centers or private clinics specialized in veterinary surgeries. In order to minimize the negative aspects of this technique and enable its use in routine clinical and surgical equine, the idea of seeking a new route to the abdominal cavity and using videocolonoscópio, lower equipment cost. In the present study, we analyzed the use of the flexible endoscope in the abdominal exploration equine barrows and gilts for access perianal. The technique was evaluated on the feasibility of allowing or not the access cavity and identification of the abdominal viscera in horses. In addition, sought to verify that the flexible endoscope allows obtaining liver tissue samples for histological evaluation. The animals were fed, wormed and evaluated daily by a general clinical examination during the period of the experiment. Sampling of blood for blood count and fibrinogen were measured before and after the surgical procedure for subsequent analysis. All routine care in relation to surgical antisepsis were duly taken and animals undergoing sedation and analgesia protocol. Procedures as postoperative analgesic therapy, anti-inflammatory, inspection and cleaning daily incision site were provided. The procedure began with surgical incision in the right laterodorsal perianal region between the anus and the semimembranosus muscle using a scalpel and scissors, then blunt dilatation of the finger along the rectal wall until it reaches an approximate depth of 10 cm, at which the metal cannula with 56 cm length and 16 mm in diameter (Ø) was introduced. Through this cannula was inserted flexible endoscope (videocolonoscópio), the remainder of the introduction of the cannula followed by indirect viewing monitor. The cannula was forced slowly to the peritoneal cavity, the time from which it was held exploration of the abdominal cavity. The cannula was forced slowly to the peritoneal cavity, the time from which it was held exploration of the abdominal cavity. The viscera were observed in annotated form specially developed for this purpose. As part of the evaluation of the liver, biopsy was performed and the obtained material analyzed at the pathology of the Veterinary School of UFRGS. After ten days postoperatively, when in full health, horses were discharged. The results allow us to conclude that the use of the flexible endoscope in the identification of abdominal viscera through perianal laparoscopy is feasible in routine clinical and surgical equine and enables to obtain tissue samples for histologic evaluation. However, the use of the technique requires training of the surgical team, especially the surgeon, good planning and a preoperative diagnosis requiring incomplete diagnostic workup.
33

Ovariohisterectomia videolaparoscópica híbrida por Acesso único e por dois portais em cadelas com até 10 Kg de peso corporal

Mottin, Tatiane da Silva January 2014 (has links)
A ovariohisterectomia (OVH) é um dos procedimentos cirúrgicos mais realizados na rotina médica veterinária e traz benefícios para a saúde do animal, como prevenção de doenças reprodutivas, e para a sociedade, já que é fundamental para o controle populacional de cães e gatos. Diversas técnicas laparoscópicas têm sido descritas para a realização de procedimentos cirúrgicos em medicina veterinária, especialmente na área de cirurgia dos pequenos animais domésticos. Um grande número de trabalhos vem estabelecendo variações em relação à técnica de OVH laparoscópica, propondo alternativas no número e localização dos trocartes, tipos de hemostasia, comparação com a cirurgia convencional, entre outras. O objetivo deste trabalho é descrever e avaliar a técnica de OVH híbrida pelo acesso laparoscópico através de um único portal (Centry Port®) em cadelas, além de comparar a mesma à cirurgia híbrida por dois portais. Utilizou-se 20 cadelas, hígidas, com peso corporal até 10 kg, que foram distribuídas em dois grupos. No grupo um (GI), a cirurgia foi realizada por um único acesso, localizado na região pré-púbica, sobre a linha alba. No grupo dois (GII), a OVH laparoscópica foi executada com o uso de dois acessos, um pré-umbilical e outro pré-púbico, ambos sobre a linha alba. Nos dois grupos, o método para hemostasia do complexo arteriovenoso ovariano foi a eletrocoagulação. A hemostasia e secção do corpo do útero foram realizados após a exteriorização deste, de forma convencional, com a técnica das três pinças. Foram avaliados os tempos cirúrgicos, as complicações trans e pós-operatórias, além da estimativa de dor utilizando a escala descritiva da Universidade de Melbourne. Observou-se que as cirurgias do GI foram realizadas em menor tempo, levando a uma diferença estatisticamente significativa no tempo cirúrgico total e no tempo cirúrgico laparoscópico em relação ao GII. Não houve diferença significativa nas avaliações de dor entre os grupos. Não foi necessário converter os procedimentos laparoscópicos para cirurgia convencional em nenhum dos animais. Concluiu-se que a OVH híbrida por single port com o uso do Centry Port® é exequível em cadelas de até 10 kg de massa corporal e, além de apresentar menor tempo cirúrgico do que a técnica por dois portais, permitindo que a cirurgia seja realizada de forma segura e sem intercorrências, mesmo que por cirurgião não proficiente. / The ovariohysterectomy (OVH) is one of the most common surgical procedures in veterinary medical routine and brings benefits to the health of the animal, such as prevention of reproductive diseases, and for society, since it is fundamental to control the population of dogs and cats. Several laparoscopic techniques have been described for surgical procedures in veterinary medicine, especially in the area of surgery for small pets. A lot of studies has been establishing variations in relation to the technique of laparoscopic OVH, proposing alternatives on the number and location of the trocars, types of hemostasis, compared with conventional surgery, among others . The objective of this study is to describe and evaluate the technique of hybrid OVH by laparoscopy through a single portal (Centry Port®) in dogs and to compare this technique with hybrid surgery by two portals. We used 20 bitches, otherwise healthy, weighing up to 10 kg were divided into two groups. In group one (GI), surgery was performed by a single access, located in the pre-pubic region, on the alba linea. In group two (GII), laparoscopic OVH was performed using two access, a pre-umbilical and other pre- pubic, both on the alba linea. In both groups, the method for hemostasis of the ovarian arteriovenous complex was electrocoagulation. Hemostasis and body section of the uterus were carried out after the uterus externalization, in conventional manner, with the technique of the three clamps. Surgery times, trans and postoperative complications were assessed, and the estimate of pain using a descriptive scale of the University of Melbourne. It was observed that the GI surgeries were performed in less time, leading to a statistically significant difference in total operative time and laparoscopic surgical time compared to GII. There was no significant difference in pain ratings between groups. It was necessary to convert the laparoscopic procedure to open surgery in any animal. It was concluded that hybrid OVH single port by using the Centry Port® is practicable in dogs up to 10 kg of body weight, as well as presenting less surgical time than the technique by two portals, allows the surgery to be performed safely and uneventfully, even for not proficient surgeon.

Page generated in 0.0368 seconds