• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • 1
  • Tagged with
  • 6
  • 6
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

The simulation of losses and computation of surge attenuation on EHV transmission lines

Al-Tai, M. A. January 1988 (has links)
No description available.
2

Advanced surge protection devices

Wilson, Robin January 1992 (has links)
No description available.
3

Monitor para caracterização de ruídos em redes de corrente alternada. / Monitor to characterise electrical noise in alternate current network.

Silva, Alvaro Macedo da 13 July 1992 (has links)
Distúrbios em redes elétricas podem causar danos materiais e/ou operacionais em equipamentos eletrônicos sensíveis, em particular, sistemas em microcomputadores. Com o objetivo de registrar esses distúrbios, um monitor para redes elétricas foi desenvolvido. O equipamento desenvolvido é controlado por um microprocessador 80C86-2. Os seguintes distúrbios podem ser monitorados: desvios da freqüência nominal da rede, interferências de rádio freqüência, subtensão, sobretensão e surtos de tensão. Para minimizar o gargalo de Von Neumann, os circuitos foram projetados de forma que a maior parte das leituras é solicitada via interrupção. O equipamento foi testado a nível de laboratório e os resultados são apresentados. / Power line disturbances can adversely affect electronic sensitive equipment, particularly microcomputer based systems. In order to register these disturbances a power line monitor has been developed. The developed instrument is microprocessor based using a 80C86-2 as the main CPU. The following electrical disturbances can be monitored: nominal frequency deviations, radio-frequency interference, under and overvoltages, transient over voltages. Attempting to minimize Von Neumann´s bottle neck, the hardware was designed in such a way that most of the readings were requested through interrupts. The equipment was tested through a series of disturbance simulations, and the results are presented.
4

Monitor para caracterização de ruídos em redes de corrente alternada. / Monitor to characterise electrical noise in alternate current network.

Alvaro Macedo da Silva 13 July 1992 (has links)
Distúrbios em redes elétricas podem causar danos materiais e/ou operacionais em equipamentos eletrônicos sensíveis, em particular, sistemas em microcomputadores. Com o objetivo de registrar esses distúrbios, um monitor para redes elétricas foi desenvolvido. O equipamento desenvolvido é controlado por um microprocessador 80C86-2. Os seguintes distúrbios podem ser monitorados: desvios da freqüência nominal da rede, interferências de rádio freqüência, subtensão, sobretensão e surtos de tensão. Para minimizar o gargalo de Von Neumann, os circuitos foram projetados de forma que a maior parte das leituras é solicitada via interrupção. O equipamento foi testado a nível de laboratório e os resultados são apresentados. / Power line disturbances can adversely affect electronic sensitive equipment, particularly microcomputer based systems. In order to register these disturbances a power line monitor has been developed. The developed instrument is microprocessor based using a 80C86-2 as the main CPU. The following electrical disturbances can be monitored: nominal frequency deviations, radio-frequency interference, under and overvoltages, transient over voltages. Attempting to minimize Von Neumann´s bottle neck, the hardware was designed in such a way that most of the readings were requested through interrupts. The equipment was tested through a series of disturbance simulations, and the results are presented.
5

A influência da resistência de terra nos efeitos das descargas atmosféricas

Santos, Camila Guesine dos 30 May 2009 (has links)
There is great concern by the power systems utilities related to disturbances that generate induced overvoltages in the power network, as they reach the consumer sensitive equipment, causing damage and losses. In consequence of this framework, the power systems utilities get large financial losses every year due to indemnity for damage to such equipments. Among the disturbances that lead to induced overvoltages are lightning. Thus, in this work it was developed the study and analysis of the lightning´s effect on loads allocated on average (11kV/15kV) and low voltage (below 600V) under the influence caused by the resistance of grounding. For modeling and simulation of the system under analysis, the program for transient study ATP (Alternative Transient Program) was used. To develop the study, it was designed a system comprising of an 88kV transmission line, a substation, a distribution line of 13.8 kV and loads representing residential consumers. It was also analyzed the use of surge suppressor in the low voltage distribution transformers as a way to mitigate the induced overvoltages that reach consumers. / Existe uma grande preocupação por parte das concessionárias de energia relacionada aos distúrbios que geram sobretensões induzidas na rede elétrica, pois estas atingem os equipamentos sensíveis dos consumidores, causando danos e perdas. Em conseqüência deste quadro, as concessionárias contraem grandes prejuízos financeiros todos os anos devido ao ressarcimento por danos a tais equipamentos. Dentre os distúrbios causadores de sobretensões induzidas destacam-se as descargas atmosféricas. Sendo assim, neste trabalho foi desenvolvido o estudo e análise do efeito de descargas atmosféricas em cargas alocadas em média (11kV/15kV) e baixa tensão (abaixo de 600V) relacionada a influência causada pela resistência de aterramento. Para a modelagem e simulações do sistema sob análise utilizou-se o programa para estudo de transitórios ATP (Alternative Transient Program). Para a realização do estudo modelou-se um sistema composto de uma linha de transmissão de 88kV, uma subestação, uma linha de distribuição de 13,8kV e cargas que representam os consumidores residenciais. É analisada também a utilização de supressores de surto na baixa tensão dos transformadores de distribuição como forma de atenuar as sobretensões induzidas que atingem os consumidores. / Mestre em Ciências
6

Metodika zabezpečování optimální přesnosti měření v souladu s metrologickou konfirmací / The Optimal Accuracy of Measurement Assurance in Accordance with Metrological Confirmation

Frank, Petr January 2009 (has links)
This thesis deals with the evaluation of accuracy of measurement and achieving the required accuracy level. This includes global analysis of the uncertainty evaluation, the calibration interval design and the creation of confirmation system. Basis of this work is in identification of all possible problems, which may occur during evaluation of accuracy and achieving the required accuracy level. The analysis is followed by suggested solutions for identified problems. It means namely the selection of probability distribution in case of uncertainty type A, evaluation of degrees of freedom in case of uncertainty type B, nonlinear correlation of input values, evaluation of coverage factor, the choice of method for calibration interval design and the procedure for meeting all metrological confirmation requirements. The last part of the thesis is practical measurement and result evaluation in the field of surge protection devices. This chapter demonstrates conclusions from the syntactical part.

Page generated in 0.0561 seconds