Spelling suggestions: "subject:"water - reuse"" "subject:"water - keuse""
181 |
Tratamento de efluentes domésticos por sistemas integrados de lodos ativados e membranas de ultrafiltração visando o reúso de água. / Domestic wastewater treatment for integrated systems of activated sludge and ultrafiltration membranes aiming at the water reuse.Costanzi, Ricardo Nagamine 30 May 2007 (has links)
No presente trabalho foram estudados sistemas pilotos de tratamento integrado de lodos ativados com sistemas de separação por membranas de ultrafiltração visando o reúso de água. O esgoto bruto utilizado foi originado do Conjunto Residencial associado ao esgoto do restaurante universitário da Universidade de São Paulo. Este esgoto possui características físico-químicas e biológicas similares ao esgoto doméstico. O esgoto utilizado nos sistemas de tratamento foi submetido à pré-tratamento: gradeamento e caixa de areia. Foram montados dois sistemas pilotos: I) sistema piloto recebendo esgoto doméstico primário com sistema de tratamento composto por reator biológico de lodos ativados (500 L de volume) e sistema de separação por membranas de ultrafiltração tipo tubular (1,4 m² de área superficial) externa ao tanque de aeração. Este sistema apresentou como resultados principais: taxas médias de produção de permeado de 22,9 ±2,7 L.h-¹.m-² e 17 ±2,7 L.h-¹.m-².bar-¹; valores característicos do permeado em relação à variável turbidez média de 0,3±0,1 UNT, cor aparente média de 31,2±4,6 mg de PtCo.L-¹, sólidos dissolvidos totais de 201±47mg.L-¹ e sólidos suspensos totais não detectável. O sistema de lodos ativados operou em regime de aeração prolongada. II) sistema piloto recebendo esgoto doméstico, após tratamento anaeróbio em reator anaeróbio de fluxo ascendente com manta de lodo (UASB), composto por reator biológico de lodos ativados (1.500 L) e sistema de separação por membrana de ultrafiltração tipo espiral (14,4m² de área superficial) interna ao tanque de aeração. Este sistema apresentou como resultados principais: taxas médias de produção de permeado de 16,1 ± 4,1 L.h-¹.m-²; valores característicos do permeado em relação à variável turbidez média 0,2±0,1 UNT, cor aparente média de 25±5 mgPtCo.L-¹ e sólidos suspensos totais não detectável. Em ambos os sistemas as eficiências de remoção de nitrogênio e fósforo podem ser consideradas pequenas. Desta forma, foram adicionados sulfato de alumínio e cloreto férrico no tanque de aeração do sistema piloto II. As dosagens variaram de 40 a 80 mg.L-¹. Os melhores resultados de eficiência de remoção de fósforo solúvel foram obtidos com o sulfato de alumínio (em torno de 79%) na dosagem de 80 mg.L-¹. / A pilot plant integrating an extended aeration activated sludge unit and an ultrafiltration membrane system was constructed and operated aiming at the production of an effluent to be reused in industrial activities. Raw wastewater was collected from a student residential building and from one of the University of São Paulo\'s restaurants. The wastewater characteristics have shown to be very close to conventional domestic wastewaters. This wastewater was submitted to preliminary treatment by screening and subsequent grit removal. Two pilots systems were studied. The first one, treating the preliminary treated wastewater by the activated sludge unit followed by the ultrafiltration membrane system of the tubular type (1,4 m² of surface area). In this case, the membrane was located external to the aeration tank. This system has shown the following main results: average rates of percolate production of 22,9 ±2,7 L.h-¹.m-².bar-¹ and 17 ±2,7 L.h-¹.m-².bar-¹; average characteristic values of the percolate as: turbidity of 0,3±0,1 UNT, apparent Color of 31,2±4,6 mg of PtCo.L-¹, total dissolved solids of 201±47mg.L-¹ and total suspended solids not detectable. The second pilot unit received the effluent from an Upflow Anaerobic Sludge Blanket (UASB) reactor and was composed by the extended aeration activated sludge reactor and an ultrafiltration membrane system of the spiral type (14,4m² of surface area), internal to the aeration tank of the activated sludge unit. This system has shown the following main results: average rates of percolate production of 16,1 ± 4.1 L.h-¹.m-²; average characteristic values of the percolate as: turbidity of 0,2±0,1 UNT, apparent color of 25±5 mgPtCo.L-¹ and total suspended solids not detectable. In both systems, the efficiencies of Nitrogen and Phosphorus removal can be considered as small. To improve the efficiencies of soluble phosphorus removal it has been added aluminum sulphate and ferric chloride to the aeration tank of the second pilot unit. The dosages had varied from 40 to 80 mg.L-¹. The best soluble phosphorus removal (about 79%) was achieved with the dosage of 80 mg.L-¹ of aluminum sulphate.
|
182 |
Pós-tratamento por membranas da água residuária do processo de tingimento de indústria têxtil com vistas ao reúso / Membranes treatment of wastewater from the dyeing process of the textile industry with a view to reuseMarques, Amanda Franzoni 18 September 2017 (has links)
A indústria têxtil é caracterizada por seu grande consumo de água e descarte de efluentes. Nesse trabalho foram mapeadas as oportunidades de reúso de água dentro da indústria têxtil de estudo. A partir desse mapeamento e dos requisitos de cada uso, foi proposto o reúso de água para lavagem de pisos e equipamentos; irrigação de jardim; preparo de banhos de tingimento e banho químico; preparo de goma; uso nas caixas de lavagem do processo de tingimento; torre de resfriamento; e descarga em vasos sanitários. O maior consumo de água ocorre no tingimento dos fios. Atualmente todo efluente gerado por esse processo é encaminhado para a Estação de Tratamento de Águas Residuárias (ETAR) e tratado por flotação por ar dissolvido (FAD). O efluente da ETAR não apresenta características que possibilitem o reúso, para isso foi estudado o uso de filtração sob pressão por membranas. Foram testadas cinco combinações diferentes de membrana envolvendo membranas de microfiltração (MF), ultrafiltração (UF) e nanofiltração (NF). A melhor configuração foi usando membrana de MF (0,05 μm) seguida de membrana de NF (200 Da) . A membrana de NF foi capaz de remover em média 68% de cálcio, 45% de condutividade, 35% da DBO bruta, 40% da DQO bruta, 62% de dureza, 48% de magnésio, 42% dos SDT, 74% de sulfato e 36% de turbidez. No entanto, o permeado não apresentou qualidade adequada para reúso direto nos processos de tigimento da indústria, pois apresentou uma elevada concentração de matéria orgância (DBO bruta 1.266 mg O2.L-1) e sais (condutividade: 8.000 μS cm-1), sendo recomendável estudos adicionais com incorporação de etapa de tratamento biológico anterior à filtração em membranas de osmose reversa, ou até mesmo de nanofiltração com eventual posterior diluição, para se avaliar a possibilidade de reúso direto no processo de tingimento. Por outro lado, a água obtida após a filtração em membrana de MF apresenta qualidade compatível com reúso para lavagens de pisos e equipamentos e descargas em vasos sanitários. / The textile industry is characterized by high consumption of water and the disposal of effluents. In this work, it was mapped the opportunities for water reuse in a tipical textile industry placed in São Carlos City, Brazil. Using the mapping and the requirements of each use, it was proposed the reuse of water to wash floors and equipment; garden irrigation; preparation of dyeing baths and chemical bath; preparation of sizing; use in the washing of the dyeing process; cooling tower; and discharged into toilets. The highest water consumption occurs in dyeing process. Currently all effluent generated by this process is sent to the Wastewater treatment plant (WWTP) of the industry and treated by dissolved air flotation (DAF). The effluent of the WWTP does not have characteristics that make possible the reuse, for this it was studied the use of filtration under pressure by membranes. Five different membrane combinations involving microfiltration (MF), ultrafiltration (UF) and nanofiltration (NF) membranes were tested. The best configuration was using a MF membrane (0.05 μm) followed by NF membrane (200 Da). The NF membrane was able to remove on average 68% of calcium, 45% of conductivity, 35% of crude BOD, 40% of crude COD, 62% of hardness, 48% of magnesium, 42% of SDT, 74% of Sulfate and 36% turbidity, however, the permeate does not have sufficient quality for direct reuse in the dying process, because it presents a high concentration of organic matter (gross BOD 1,266 mg O2.L-1) and salts (conductivity: 8.000 μS cm-1), but it is recommended that additional studies incorporate a biological treatment step prior to filtration in reverse osmosis membranes, or even nanofiltration with eventual dilution, to evaluate the possibility of direct reuse in the dyeing process. On the other hand, the water obtained after MF membrane filtration presents quality compatible with reuse for floor washes and equipment and discharges in toilets.
|
183 |
Avaliação de um sistema de reuso de água: o caso de um parque temático / Reuse of water system evaluation:A thematic park casePhilippi, Caio Tucunduva 20 October 2006 (has links)
Empreendimentos imobiliários, em nível mundial, vem experimentando mudanças tecnológicas, a fim de melhorar sua compatibilidade com o meio ambiente. Diminuição e reaproveitamento dos efluentes são aspectos importantes, uma vez que estão relacionados diretamente com a saúde da população. Entretanto, essa preocupação não se aplica apenas à diminuição da emissão de esgotos, mas também a boa operação do sistema, destacando-se o uso da água para limpeza, rega de jardim e sanitários. Nesse sentido, escolheu-se como estudo de caso um parque temático onde procurou se desenvolver e implantar de forma racional o uso dos recursos naturais locais levando em consideração o conceito de desenvolvimento sustentável. Assim, os fatores que levaram a empresa a investir no sistema de reúso de água foram: a preocupação com a utilização intensiva dos recursos hídricos e política de qualidade e ambiental da empresa. Este projeto então tem como objetivo demonstrar e analisar a viabilidade técnica de sistemas de captação, tratamento e reúso de efluentes estabelecendo uma proposta para reúso de água em empreendimentos imobiliários, tecnica e legalmente compatível com as condições internacionais, diagnosticando o atual sistema de tratamento dos esgotos domésticos do empreendimento estudado, especificando a qualidade da água para as diversas modalidades de reúso de água. Como conclusão comparou-se os limites estipulados pelo empreendedor com os limites impostos pela legislação internacional recomendando assim um monitoramento intensivo no sistema de desinfecção assim como a implantação de um sistema de gerenciamento ambiental eficiente voltado para o controle operacional do sistema de reúso. / Technological changes in real estate developments have been taking place across the world so as to improve their compatibility with the environment. Effluent reduction and reuse are critical issues, as they are directly related to the populations health. However, such concern not only applies to the reduction of sewage discharge, but also to the proper system operation. The use of water for cleaning, garden watering and restrooms stands out. In that sense, a theme park in which efforts were made to develop and implement in a streamlined manner the use of local natural resources while taking into account the sustainable development concept has been selected as a case study. Thus, the factors that led the company to invest in the water reuse system include: the concern about the intensive use of water resources and the companys quality and environmental policy. Therefore, the purpose of this project is to demonstrate and assess the technical feasibility of waste catchment, treatment and reuse systems as well as to put forward a proposal technically and legally consistent with international standards for water reuse in real estate development, while evaluating the current domestic waste treatment system of the venture under consideration and determining the water quality for the various water reuse methods. As a conclusion, the limits set by the developer have been compared with those imposed by the international law; intensive monitoring of the disinfection system and the implementation of an effective environmental management system focused on the operational control of the reuse system are recommended.
|
184 |
Remoção de ovos de helmintos de esgotos secundários, por meio de filtros rápidos de areia, carvão antracitoso e zeólito para reúso agrícola e urbano não potável. / Removal of helminth eggs in sewage side, through rapid sand filters, anthracite coal and zeolite for agricultural reuse and urban non-potable.Gobbi, Sidinei Antonio 22 February 2010 (has links)
A presença de ovos de helmintos é um dos principais problemas do reúso de esgotos tratados na irrigação agrícola e no reúso urbano não potável. Isso porque pode haver contaminação dos trabalhadores que manipulam a água de reúso e da população consumidora. Os ovos de helmintos não são removidos com eficiência por meio de operações e processos unitários convencionais. Esses processos não possibilitam a remoção de ovos de helmintos a níveis estabelecidos pelas diretrizes da Organização Mundial da Saúde (OMS) para o reúso. Avaliar a filtração até a gravidade, como unidade complementar de tratamento, para a remoção de ovos de helmintos é o objetivo desta pesquisa. Como os efluentes de estações de tratamento de esgotos locais apresentam concentrações muito variáveis de ovos de helmintos, foi utilizada uma solução sintética de ovos padronizados Ascaris suum. A solução sintética preparada com o uso dos ovos padronizados foi usada na determinação dos parâmetros de operação do processo de filtração. Após esses ensaios, foram realizados testes em escala piloto com esgoto tratado, objetivando o estudo da influência da matéria orgânica, dos sólidos e de outros interferentes do processo. Os experimentos com solução sintética foram desenvolvidos nos laboratórios do Centro Internacional de Referência em Reúso de Água (CIRRA), da Escola Politécnica da USP. As experiências com esgoto tratado foram realizadas na ETE do ABC, da SABESP. Os resultados mostraram que as três colunas de filtração foram muito eficientes na remoção dos ovos de helmintos, produzindo um efluente com concentração final inferior a 1 ovo/l. Além disso, a filtração possibilitou a remoção de sólidos suspensos totais, turbidez, cor e material orgânico particulado, resultando em um efluente com grande potencial para ser reusado na irrigação agrícola, bem como no reúso urbano não potável. / Helminth eggs are one of the major problems regarding the reuse of treated sewage in agriculture and non-potable urban irrigation since both workers who handle the effluent and the consumer population might become contaminated. Helminth eggs are not efficiently removed by conventional unit operations and processes, which do not allow the removal of helminth eggs at levels established by the World Health Organization guidelines. The objective of this research is to assess the gravity filtration as an additional unit of treatment for the removal of helminth eggs. Since local effluent sewage treatment stations have highly variable concentrations of helminth eggs, a synthetic solution of standardized Ascaris suum was used. The synthetic solution prepared with standardized eggs was used to determine the operating parameters of the filtration process. Following the trials, pilot scale tests with treated sewage were conducted aimed at evaluating the influence of organic materials, solids, among other materials which might interfere in the process. Experiments with synthetic solution were performed in the laboratory of the International Center of Water Reuse - CIRRA, at the Polytechnic School of the University of São Paulo. Experiments with treated sewage were performed at ETE - ABC, SABESP. The results showed that the three filtration columns were very efficient in removing helminth eggs, which resulted in an effluent with a final concentration of < 1 egg/L. In addition, the filtration allowed the removal of total suspended solids, turbidity, color, and particulate organic material, resulting in an effluent with great potential to be reused in irrigation as well as in non-potable urban reuse.
|
185 |
Utilização de água residuária do processo pós-colheita do café na produção de mudas de cafeeiro /Melo, Augusto Cezar de Paula e, 1983- January 2009 (has links)
Resumo: Com o intuito de alcançar maiores produtividades de café, cafeicultores começaram, a partir da década de 80, a fazer uso do processamento pós-colheita de café, a fim de garantirem uma qualidade superior de seu produto. Porém, com o processamento, houve o surgimento de outro problema a água residuária de café (ARC) que passou a contaminar rios, ribeirões, solos, lençol freático, etc. Este trabalho teve como objetivo utilizar a ARC na produção de mudas de café verificando sua viabilidade e a capacidade de a ARC em suprir as necessidades das mudas com relação ao potássio, quando estas não recebem cloreto de potássio no solo utilizado. O trabalho foi desenvolvido na Faculdade de Ciências Agronômicas - UNESP, Botucatu - SP em uma casa de vegetação localizada no Departamento de Engenharia Rural, consistiu de 10 tratamentos em um fatorial 5x2 (5 proporções de água residuária de processamento pós-colheita do café - 0%, 25%, 50%, 75% e 100% - e presença ou ausência de cloreto de potássio no solo utilizadoo), com 4 repetições dispostos em delineamento inteiramente casualizados. A ARC foi aplicada a cada 48 horas com uma lâmina de 10 mm. Após 6 meses, foram avaliadas características vegetativas das plantas e características químicas do solo e das plantas. Constatou-se que os tratamentos com a presença de cloreto de potássio foram estatisticamente inferiores aos tratamentos que não apresentavam KCl em seu solo quanto às características vegetativas. Com o aumento das proporções de água residuária, houve um decréscimo nas características vegetativas, porém um acréscimo nas características químicas do solo. Além disso, os tratamentos sem a presença de KCl e com 0% e 25% de água residuária de café foram estatisticamente iguais, mostrando a viabilidade no uso da ARC na produção... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract : Intending to achieve better results on coffee production, the coffee producers began, since the 80s to process the coffee post harvest, in order to ensure product's superior quality. But, with the processing, other problem appeared, the coffee wastewater (ARC - água residuária de café), which start the contamination of rivers, creeks, soil, water tables etc. This paper had as main objective to use the ARC on the coffee plants' production verifying its viability and to verify if the ARC is able to supply the coffee needs relating to potassium when these don't receive potassium chloride in the composition. The work was developed at Faculdade de Ciências Agronômicas - UNESP, Botucatu - SP in a greenhouse located at Departamento de Engenharia Rural. The work consisted of 10 treatments on a 5x2 factorial (5 wastewater proportions of coffee after the harvest processing - 0%, 25%, 50%, 75% and 100% - and potassium chloride presence or absence in the soil), with 4 repetitions made in delineation entirely design. The ARC was applied each 48 hours with a blade of 10 mm. After 6 months, the plants vegetative characteristic had been evaluated as well the chemical characteristics of the soil and of the plants. We observed that the treatments with potassium chloride presence had been statistically inferior to the treatments which did not present KCl in its soil related the vegetative characteristics. Moreover, with the increase of the wastewater proportions, it happened a decrease in the vegetative characteristics, however an addition in the chemical characteristics of the soil. Also, the treatments without KCl presence and with 0% and 25% of coffee wastewater had been statistically equal, showing the viability in the use of the ARC in the production of coffee plants, since the soil does not contain KCl and that the water used in the soil was a mixture of 25% of ARC with 75% of common water. / Orientador: Antônio de Pádua Sousa / Coorientador: Roberto Lyra Villas Bôas / Banca: Maritane Prior / Mestre
|
186 |
Utilização de reator aeróbio de leito fluidizado com circulação em tubos concêntricos no tratamento de águas residuarias da produção intensiva de tilapia com recirculação da água tratada /Maigual Enriquez, Yemall Alexander. January 2011 (has links)
Orientador: Tsunao Matsumoto / Banca: Alexandre Ninhaus Silveira / Banca: Katt Reginal Lapa / Resumo: Sistemas de Recirculação para Aquicultura (SRA) possibilitam um meio alternativo de produção de peixes para áreas com limitada disponibilidade de água. Estes sistemas de cultivo intensivo de peixes oferecem potencial de produção em pequena escala assim como em grande escala, devido a recuperação de efluentes e a reutilização da água, produzindo volumes relativamente pequenos de resíduos líquidos e sólidos. O objetivo deste estudo foi determinar a eficácia do tratamento de águas residuárias em relação à remoção de Nitrogênio Amoniacal Total (NAT), Sólidos Totais (ST), Sólidos Suspensos Totais (SST), Demanda Química de Oxigênio (DQO) e Demanda Bioquímica de Oxigênio (DBO5), Nitrogênio total (NT) e Fósforo Total (FT). Para tanto, foram introduzidos Tilápia do Nilo (Oreochromis niloticus), com 0,323kg de peso médio inicial e 17 kg m-3 de densidade de armazenamento inicial no SRA experimental. O SRA era composto de 03 tanques de plástico com capacidade de 0,20 m3, Decantador de Coluna (DC), o reator de leito fluidizado aeróbio com circulação em tubos concêntricos (BAS-CT), tendo como meio de suporte a areia de diâmetro efetivo (D10) = 0,29 mm e na sequência reator de transferência de oxigênio e remoção de CO2. A eficiência na remoção do NAT no reator BAS-CT no período de aclimatação e de estabilização foi 31,0% e 35,2%, respectivamente. A remoção de ST e SST foi de 44,44% e 71,71%, respectivamente. A eficiência alcançada de remoção no SRA da DQO foi de 64,90% e de 48,01% para DBO5. Os valores médios de remoção do NT e FT no SRA foram de 25,02% e 41,05%, respectivamente. Estes resultados indicaram que o tratamento de águas residuárias de aquicultura proposto neste estudo através do BAS-CT associado ao DC tem evitado elevadas concentrações e acumulação de poluentes dentro do SRA / Abstract: Recirculating aquaculture systems (RAS) offer an alternative means of fish production for areas that to have limited water and land availability. RAS are a highly intensive fish culture systems and offer potential production units for small and large scale operations. For effluent recovery and treated water reuse, RAS produce relatively small volumes of liquid and solids wastes. The objective of this study were to determine the efficiency of the wastewater treatment with recommended to removal of Total Ammonia Nitrogen (TAN), Total Solids (TS), Total Suspended Solids (TSS), Chemical Oxygen Demand (COD) and Biochemical Oxygen Demand (BOD5), Total Nitrogen (TN) and Total Phosphorus (TP). In this study was cultivating the Nile Tilapia (Oreochromis niloticus) with 0.323kg initial average weight and 17 kg m-3 initial storage density, cultivated in RAS. The RAS was composed with 03 plastic tanks with capacity of 0.20 m3 in each, column settler (CS), aerobic fluidized bed reactor with concentric tubes circulation (BAS-CT) with sand bed support of effective diameter (D10) of 0.29 mm and oxygen transfer-CO2 removal reactor. NAT removal efficiency was in acclimation and stabilized periods in BAS-CT reactor were 31.0% and 35.2% respectively. TS and TSS removal was 44.44% and 71.71% respectively. In this RAS, the COD removal efficiency reached was 64.90% and 48.01% for BOD5. The average removal in the NT and FT in the RAS were 25.02% and 41.05% respectively. These results indicate that aquaculture wastewater treatment proposed in this study by BAS-CT associated to CS prevents high concentrations and accumulating of pollutants within the SRA
|
187 |
Estimativa da correção do coeficiente de retorno de esgoto sanitário em habitações com sistemas de aproveitamento de água pluvial : estudo de caso da cidade de Bauru (SP) /Leão, Cintia Loturco Pinheiro. January 2015 (has links)
Orientador: Rodrigo Braga Moruzzi / Banca: Fabiano Tomazini da Conceição / Banca: Marcelo de Julio / Resumo: Vário estudos têm sido realizados propondo técnicas de conservação de água, visando minimizar o consumo de água tratada. Dentre eles destaca-se o aproveitamento de água pluvial em atividades que possam prescindir da potabilidade. No Brasil, a cobrança dos serviços de coleta e tratamento de esgoto sanitário, em geral, é realizada com base no volume de água tratada medida do hidrômetro da unidade consumidora. Portanto, esse descarte de esgoto gerado pelo sistema de aproveitamento de água pluvial não é contabilizado pelo sistema de tarifação de esgoto no custo de destinação e tratamento. A utilização dessa água pluvial subestima o volume de esgoto gerado. Este trabalho propõe a aplicação da metodologia para o ajuste desse coeficiente de retorno visando estimar o volume de água pluvial lançado na rede coletora de esgoto indexado ao volume de água tratada medido no hidrômetro de cada unidade consumidora. A bacia sanitária com caixa acoplada foi adotada como objeto de estudo. A partir da coleta de amostragens de áreas de telhado do município de Bauru (SP), determinou-se a área média de telhado. Diferentes simulações de determinação de áreas de telhado, volumes de reservatórios e demandas de consumo de água foram realizadas, com o intuito de analisar o comportamento do ajuste do coeficiente de retorno para a área média de telhado per capita (m2.hab-1). Os resultados apontaram que o município de Bauru (SP) apresent uma área de telhado da ordem de 139,91 = 3,12m2 para residências, de 5,58 m2.hab-1 para apartamentos e uma área média ponderada de 132,18 m2 por domicílio. Apresentando uma área média per capita de 49,21 m2. Verificou-se que em todas as faixas de consumo per capita, para o volume de reservatório de 0,5 m3.hab-1, o lançamento de água pluvial na rede coletora de esgoto apresentou eficiência com valores menores que 30% para as áreas específicas de cobertura de 4 a 17 m2.hab-1, portanto... / Abstract: Several studies have been conducted proposing water conservation techniques to minimize the treated water consumption. Among them stands out the rainwater utilization in activities that may dispense the potability. In Brazil, the pricing on the collection and treatment services of sewage, is generally performed based on the volume of treated water measured at the meter of the consumer unit. Therefore, this sewage disposal generated by rainwater utilization system is not accounted for sewage charging system on the cost of disposal and treatment. The use of this rainwater underestimates the volume of sewage generated. This paper proposes the application of the methodology for setting this return coefficient to estimate the volume of rainwater released in the sewage disposal system linked to the volume of treated water measured at the meter of each consumer unit. The sanitary bowl with box attached was adopted as an object of study. From the collection of roof areas sampling the city of Bauru (SP) determined the average area of the roof. Different simulations of determining roof areas, reservoir volumes and water consumption demands were made, in order to analyze the return coefficient setting behavior for the average area of roof per capita (m2.hab-1). The results showed that the city of Bauru (SP) features a roof area of approximately 139.91 = 3.12 m2 for homes, 5.58 m2.hab-1 for apartments and wa weighted average area of 132.18 m2 per household. With an average are per capita of 49,21 m2. It was found that in all per capita consumpetion ranges, for volume of 0.5 m3 reservoir/in habitant, the release of rainwater in the sewage disposal system was efficient with values less than 30% specific coverage areas 4-17 m2.hab-1 therefore concluded that discharges into sanitary bowl were not met fully by rainwater utilization system. In this way it was stated that not all use of water for unloading in sanitary bowl is transferred to the collection... / Mestre
|
188 |
Análise da viabilidade de implantação de um sistema de captação de água de chuva para lavagem de aeronaves e reuso de efluentes /Silva, Janaina Andréa. January 2018 (has links)
Orientador: Teófilo Miguel de Souza / Banca: Osiris Canciglieri Júnior / Banca: Eliana Vieira Canettieri / Resumo: O objetivo deste trabalho foi analisar a viabilidade de implantação de um sistema de captação de água de chuva para abastecer o processo de lavagem de aeronaves na EMBRAER, e este estudo pode ser estendido para aplicação aos centros de manutenção de companhias aéreas nacionais e aeroportos. O trabalho consiste em um estudo de caso. Em sua realização foram analisadas as condições locais para implantar o sistema de coleta de água de chuva, a quantidade de recurso pluvial disponível na região de São José dos Campos, a necessidade de armazenagem de água para suprir períodos de estiagem, a qualidade necessária da água para atender a esta finalidade, e as aplicações para o reuso do efluente da lavagem de aeronaves. Os resultados mostraram que o volume de água de chuva disponível na região é suficiente para abastecer o processo de lavagem das aeronaves e que a água tem qualidade suficiente para esta aplicação. O trabalho mostra ainda que com a reutilização do efluente gerado na lavagem de aeronaves torna a implantação do projeto viável e que além do retorno financeiro, a proposta traz benefício ambiental, preservando o recurso hídrico de boa qualidade / Abstract: The aim of this work was to verify the feasibility of introduce a rainwater harvesting system to supply the aircraft washing process at EMBRAER and this study may be extended to the airlines maintenance centers and airports. This work consists in a case study. To perform this work were studied the local conditions to introduce the rainwater harvesting system, the amount of rainfall available in São José dos Campos, the need to storage water to supply drought periods, the quality of the water to supply the process with security and the applications for reuse the effluent from aircraft washing process. The results showed that the amount of rainwater avaiable in the region is enough to supply the aircrafts washing process and the water is sufficient in quality for this application. The work also showed that the reuse of the effluent generated by the aircraft washing process makes feasible the project implementation. In addition to the financial return, the purpose brings environmental benefits preserving the good quality water resources / Mestre
|
189 |
As dimensões legais e institucionais do reuso de água no Brasil: proposta de regulamentação do reuso no Brasil. / Basis for an institutional structure and a legal framework to control and to regulate the practice of water reuse in Brazil.Rodrigues, Raquel dos Santos 06 June 2005 (has links)
O reuso de água surge como um instrumento adicional para a gestão dos recursos hídricos, visando a redução da pressão sobre os mananciais de abastecimento, liberando as águas de melhor qualidade para os fins mais nobres, e trazendo uma série de benefícios específicos aos usuários, tais como o aumento de produtividade agrícola, a redução de custos com a compra de água e a preservação dos aqüíferos subterrâneos. Entretanto, enquanto a prática do reuso se dissemina no Brasil, não há a criação de nenhuma legislação específica visando regular o setor, proteger o meio ambiente e a saúde dos grupos de risco. Esta dissertação foi desenvolvida com o objetivo de fornecer uma base sobre a estrutura legal e institucional responsável pelo controle e regulação do reuso no Brasil. São apresentadas as diretrizes gerais sobre o conteúdo necessário para uma regulamentação específica, ressaltando-se o arcabouço institucional necessário (nível federal e local), os tipos de reuso que precisam ser regulamentados, os incentivos que podem ser criados, quais as condições para a outorga e a cobrança com a implementação do reuso e as condições de interface com o licenciamento ambiental. A abordagem do estudo visa fornecer ferramentas para a solução dos conflitos que possam surgir à medida que o reuso for implementado. Também foram consideradas as criações de um sistema nacional de informações sobre o reuso de água e de programas de educação para a promoção e entendimento do reuso. / Water reuse appears as an additional instrument for water resources management. It will contribute to reduce demand pressure to fresh water sources, liberating high quality waters for potable purposes and providing a series of benefits such as agricultural productivity increase, cost reduction and ground water preservation. However, while the practice of water reuse has already been implemented in Brazil, no specific legislation has been made available to regulate the sector and to provide environmental protection as well as health safeguards to the groups at risk. This dissertation was prepared with the objective of providing the basis for an institutional structure and a legal framework to control and to regulate the practice of water reuse in Brazil. Proposals were made for the build up of institutional arrangements, both at federal and watershed levels, the types of wastewater reuse to be regulated, incentives, conditions for the implementation of a command and control system as well as permit and charging considerations. The basic approach was directed to provide tools for the solution of conflicts that can occur when water reuse projects are implemented. Consideration was also given to the implementation of a national water reuse information system and educational programs to promote and to make the practice of reuse understood to the lay man.
|
190 |
Conservação e reúso de água em indústria de cosméticos: estudo de caso da Natura Cosméticos. / Water conservation and reuse in domestics industry: case study of natura cosméticos.Alves, Sebastião Sampaio 15 May 2009 (has links)
Para a indústria de produtos de higiene e cosméticos o recurso água é de primordial relevância, considerando as quantidades e a qualidade necessárias para a condução dos processos de produção. O agravamento da escassez de água, devido ao crescimento populacional e às atividades industriais, pressionam para a elaboração de leis e normas que restringem o uso da água, elevam os custos para a sua obtenção e impõem maiores controles sobre o tratamento e lançamento de efluentes. Assim, as técnicas de conservação e reúso de água passam a ser elementos diferenciais nos resultados das empresas que as utilizam, além, é claro, do evidente benefício para a sociedade e meio ambiente. Este trabalho tem o objetivo de apresentar um estudo de caso mostrando técnicas utilizadas na conservação e reúso de água no segmento industrial de fabricação de cosméticos. São descritas as dificuldades e limitações existentes, em função das características do processo produtivo e das exigências de qualidade e normas sanitárias. Entretanto, apesar dessas limitações, mostra-se ainda que existem oportunidades para redução dos índices de consumo do recurso água, através de modificações em processos de lavagem de tanques e reatores, controle de perdas, eliminação de desperdícios, conscientização e treinamentos de operadores. Essas ações podem levar a economias substanciais, que podem chegar a até 80 % em alguns dos processos investigados. São ações que podem ser aplicadas em complementação ao programa de conservação existente. / Water is an essential resource for the manufacturing of personal care products and cosmetics, when account is taken of the amount and quality required for carrying out these production processes. The water scarcity, due to the population growth and expansion of industrial activities, are leading the authorities to draw up laws and regulations to restrict the use of water, raise the costs of its supply and impose greater control over its treatment and the discharge of effluents. Thus, conservation techniques and water reuse are becoming distinct factors in the results of the companies which employ this technology, besides the fact that there are evident benefits to the society and the environment. The purpose of this paper is to discuss a case study which examines the techniques for conserving and reusing water in the manufacturing sector of the cosmetics industry. The difficulties and restrictions on water conservation and reuse are described with regard to the way it is supplied and current quality and sanitation requirements. However, despite the fact that these restrictions are in force, it is also shown that there is still opportunity for reducing the level of consumption of this resource. This includes changes in the way tanks and reactors are cleaned, better control of water loss, cutting waste in water operations, and ensuring that a proper training is given to the operators so that they are made aware of the problems. These measures can also lead to substantial savings, which, it was estimated, reached a level of 80 % in some processes investigated. The findings of this study suggest that there is a need to supplement the conservation program already in practice.
|
Page generated in 0.078 seconds