• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 4
  • 4
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Caracterização funcional de adjuvantes em soluções aquosas /

Oliveira, Rone Batista de, 1977- January 2011 (has links)
Orientador: Ulisses Rocha Antuniassi / Banca: Otavio Jorge Gricoli Abi Saab / Banca: Marco Antonio Gandolfo / Banca: Carlos Gilberto Raetano / Banca: Paulo Roberto Arbex Silva / Resumo: A alta demanda por agrotóxicos pelos sistemas de produção agrícola, aliada ao possível uso inadequado desses produtos, torna a deriva um dos maiores problemas potenciais da agricultura atual, e a escolha correta de adjuvantes pode ser uma das alternativas para minimizar os impactos negativos causados pela deriva nas pulverizações. Este trabalho foi desenvolvido com o objetivo de avaliar o efeito proporcionado por diferentes grupos de adjuvantes nas propriedades físicas e químicas das soluções, no espectro de gotas, bem como no potencial do risco de deriva quantificado em túnel de vento, como forma de auxiliar na escolha correta desses produtos para melhor utilização nas aplicações de agrotóxicos. Foram selecionados 18 adjuvantes comumente utilizados em misturas com agrotóxicos em pulverizações agrícolas, avaliando-se as propriedades físicas e químicas dos mesmos em soluções aquosas (viscosidade, densidade, tensão superficial e condutividade elétrica), o espectro de gotas e o potencial de deriva medido em túnel de vento. O experimento foi composto de 33 tratamentos, tendo a água como testemunha adicional, resultantes da diluição dos adjuvantes em diferentes concentrações, com três repetições. Para os ensaios em túnel de vento e análise de espectro de gotas foi utilizada uma ponta de pulverização XR8003 VK na pressão de 200 kPa, gerando um padrão de gotas médias. A deriva foi coletada no túnel de vento com fluxo de ar na velocidade de 2 m s-1. O corante Azul Brilhante a 0,6% (m v-1) foi utilizado como marcador para todas as soluções pulverizadas visando a quantificação da deriva por espectrofotometria. Os resultados mostraram que a adição de adjuvantes alterou as propriedades físicas e químicas das soluções aquosas em diferentes magnitudes, dependendo da concentração utilizada. Os surfatantes organosilicones... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Due to the high demand for pesticide by the agricultural systems and the possible inadequate use of the products, drift became one of the biggest concerns of the modern agriculture, and the correct use of adjuvants may be one of the possible alternatives to minimize the negative impact of spray operations. This study was developed to evaluate the effect of different adjuvants on physical and chemical properties of spray solutions, droplets spectra as well as drift potential measured in wind tunnel, aiming the correct choice of adjuvants to improve efficiency in pesticide application. For this purpose 18 commercially available agricultural spray adjuvants were selected including products usually mixed up with pesticides in the sprayer tank. The evaluation included physical and chemical properties of spray solutions (viscosity, density, surface tension and electric conductivity), droplets spectra and drift risk potential measured in wind tunnel. The experiment was set up with 33 treatments (solutions) obtained from 18 adjuvants used in different concentrations with 3 replications, including pure water as a standard. For wind tunnel tests and droplet spectra analysis it was used a Teejet XR8003 flat fan nozzles at 200 kPa (medium droplets) and all solutions were mixed up with a food color dye (Blue FDC) at 0,6% m v-1 for spectrophotometry analysis of drift deposits on the wind tunnel. The results showed that the addition of adjuvants changed physical and chemical properties of spray solutions in different magnitudes according to the product concentration. The organosilicon surfactants (Silwet 0.1% e 0.2% and BreakThru 0,1%) had the lowest values for surface tension, while the drift retardant based polymers (Define 0,06% e 0,12%) had the highest values for viscosity and density. There was high correlation between the Volume Median Diameter (VMD) and percentage of droplets smaller... (Completo abstract click electronic access below) / Doutor
2

Estudo teórico e experimental das curvas características de um ventilador axial aplicado em pulverização agrícola /

Fogal, Marcelo Luiz Freitas. January 2009 (has links)
Orientador: Alcides Padilha / Banca: Ivan De Domenico Valarelli / Banca: Kamal Abdel Radi Ismail / Resumo: Neste trabalho apresenta-se uma análise teórica e experimental dos resultados comparativos entre as curvas características de um ventilador axial utilizado em um sistema de pulverização agrícola para um ângulo de ataque da pá em 32 graus nas rotações de 1500, 1750, 2600 e 3000 rpm e resultados numéricos da influência da variação do ângulo de ataque da pá em 28, 32 e 36 graus e da otimização do sistema de pulverização ambos para uma rotaç]ao de 2600 rpm. O campo médio turbulento foi obtido com a aplicação da média temporal sendo que o modelo de turbulência exigido para o fechamento do conjunto de equações foi o modelo k-ε de duas equações. A resolução de todos os fenômenos acoplados foi alcançada com o auxílio do código de fluidodinâmica computacional CFX que utiliza a técnica dos volumes finitos como método numérico. Para validação da análise teórica, realizaram-se experimentos em um túnel de vento horizontal de seção circular com diâmetro de 622 mm, usando um tubo de Pitot para as tomadas de pressão de acordo com a norma para ensaios em laboratório. Apresentam-se resultados qualitativos na forma de vetores e mapas de gradiente de velocidade e, quantitativos na forma de tabelas e gráficos para as curvas características. / Abstract: This paper presents a theoretical and experimental analysis of comparative results the characteristic curves of an axial fan used in an agricultural spraying system for a blade attack angle of 32 degrees at rotations of 1500, 1750, 2600 and 3000 rpm and numerical results for the influence of blade attack angle variation at 28, 32 and 36 degrees and optimization of the spraying system, both for a rotation of 2600 rpm. The average turbulent field was obtained from the application of time average where the turbulence model required for closing the set of equations was the k-ε model for two equations. Resolution of all connected phenomena was achieved with the help of the fluid dynamics computacional, CFX, which uses the finite volumes technique as a numerical method. In order to validate the theoretical analysis, an experiment was conducted in a circular section of a horizontal wind tunnel, 622 mm in diameter and 6220 mm in length, using a Pitot tube for pressure readings according to the norm for laboratory assays. Qualitative results are shown as vectors and gradient maps for speed and quantitative results are shown in tables and graphics for characteristic curves. / Mestre
3

Análise numérica e experimental na determinação da potência térmica dissipada em componentes eletrônicos /

Sousa, Reginaldo Ribeiro de. January 2008 (has links)
Orientador: Amarildo Tabone Paschoalini / Banca: Luiz de Paula do Nascimento / Banca: Marcelo Moreira Ganzarolli / Resumo: Os objetivos deste trabalho são determinar a potência térmica dissipada dos componentes eletrônicos de forma experimental e verificar a eficácia do método através de simulações numéricas computacionais utilizando o software comercial ANSYS. O Software ANSYS foi usado como ferramenta de Dinâmica de Fluidos Computacional neste trabalho. Para a realização deste trabalho um ensaio experimental foi executado a fim de obter alguns dados para o cálculo da potência térmica dissipada, outros foram fornecidos pelo CPqD e Trópico. Foi montado um Laboratório Computacional com o apoio da Trópico e do CPqD na UNESP, campus de Ilha Solteira para a simulações numéricas. O método de cálculo de potência apresentou-se eficaz, de modo na melhor situação os resultados apresentaram um erro relativo médio de 1,94%. / Abstract: The purpose of this study is to determine the thermal power dissipation of electronic components through an experimental test and verify the effectiveness of the method through numerical simulations using the computational software ANSYS commercial. Software ANSYS was used as a tool for Computational Fluid Dynamics for this work. For this work an experimental test was done to obtain some data to calculate the thermal power dissipation, others were supplied by CPqD, Nilko and Trópico. It was dubbed a Computer Laboratory with the support of the Trópico, CPqD and at UNESP, campus de Ilha Solteira for the numerical simulations. The method of calculation of power proved to be effective, that the better the results showed a mean relative error is 1.94%. / Mestre
4

Determinação da deriva da mistura 2,4-D e glyphosate com diferentes pontas de pulverização e adjuvantes /

Costa, Augusto Guerreiro Fontoura, 1976- January 2006 (has links)
Resumo: O objetivo do trabalho foi avaliar os efeitos de diferentes pontas de pulverização e adjuvantes sobre a intensidade do processo de deriva, o espectro de gotas e a tensão superficial dinâmica das soluções de aplicação da mistura de 2,4-D e glyphosate. Os ensaios foram realizados no Silsoe Research Institute, Inglaterra. Os tratamentos corresponderam à combinações entre tipos de pontas de pulverização e adjuvantes. As pontas e respectivas pressões utilizadas foram: jato plano convencional de uso amplo XR 11002 (3 e 1,5 bar), jato plano com pré-orifício DG 11002 (3 bar), jato plano defletor com pré-orifício TT 11002 (3 bar), jato plano com pré-orifício e indução de ar AI 11002 (3 bar) e jato cônico vazio TXVS-10 (4 bar). Os adjuvantes e concentrações (v/v) testados foram: Minax (900 g.L-1 de óxido de etileno condensado – alquil fenol) a 0,1%, Ethokem (870 g.L-1 de amina graxa poli ethoxilada) a 0,5%, Actipron [96,8% (p/p) de óleo mineral] a 1,0%, Rigger (840 g.L-1 de óleo vegetal metilado) a 1,0% e Silwet L-77 [80% (p/p) de óxido de poli (alquileno) modificado - heptametil-trisiloxano] a 0,1%. Os herbicidas utilizados foram Headland Staff 500 (500 g.L-1 de 2,4-D, Headland Agrochemicals Ltd, Reino Unido) em mistura com Scorpion (360 g.L-1 de glyphosate, Cardel Agro SPRL, Reino Unido) a 0,8 e 3,5% de concentração (v/v), respectivamente. As aplicações foram realizadas com e sem os herbicidas na calda. A deriva 2 foi avaliada em condições de túnel de vento, com velocidade do fluxo de ar de 2 m.s-1 e umidade relativa do ar a 80%. Os coletores de deriva foram fios de polietileno de 1,9O objetivo do trabalho foi avaliar os efeitos de diferentes pontas de pulverização e adjuvantes sobre a intensidade do processo de deriva, o espectro de gotas e a tensão superficial dinâmica das soluções de aplicação da mistura de 2,4-D e glyphosate...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this research was to evaluate the effects of different nozzles and adjuvants on the drift process intensity, the droplet spectra and the dynamic surface tension of spray solutions of 2,4-D + glyphosate mixture. The trials were carried out in the Silsoe Research Institute, England. The treatments corresponded to combinations between nozzle designs and adjuvants. The nozzles and respective pressures used were: conventional extended range flat fan XR 11002 (3 and 1.5 bar), pre orifice flat fan DG 11002 (3 bar), pre orifice deflector flat fan TT 11002 (3 bar), pre orifice air induction flat fan AI 11002 (3 bar) 4 and hollow cone TXVS-10 (4 bar). The adjuvants and concentrations (v/v) tested were: Minax (900 g.L-1 alkyl phenol ethylene oxide condensate) at 0.1%, Ethokem (870 g.L-1 ethoxylated tallow-amine) at 0.5%, Actipron [97% (w/w) mineral oil] at 1.0%, Rigger (840 g.L-1 methylated vegetable oil) at 1.0% and Silwet L-77 [80% (w/w) polyalkylene oxide modified heptamethyl trisiloxane] at 0.1%. The herbicides used were Headland Staff 500 (500 g.L-1 of 2,4-D, Headland Agrochemicals Ltd, UK) in mixture with Scorpion (360 g.L-1 of glyphosate, Cardel Agro SPRL, UK) at 0.8 e 3.5% concentration (v/v), respectively. The applications were made with and without herbicides in the spray liquid. The spray drift were assessed under wind tunnel conditions, with air flow velocity of 2 m.s-1 and air relative humidity of 80%. The spray drift collectors were 1.98 mm diameter and 2.75 m length polythene lines, placed horizontally at 0.1, 0.2, 0.3, 0.4 and 0.5 m high at 2 m distance from the nozzle and at 2, 3, 4, 5, 6 and 7 m distance at 0.1 m high. The food dye gGreen Sh was used as a tracer. The collectors were individually washed with de-ionised water and the washing solutions were analyzed by spectrophotometry...(Complete abstract click electronic access below) / Orientador: Edivaldo Domingues Velini / Coorientador: Paul Charles Harvey Miller / Banca: Carlos Roberto Raetano / Banca: Ulisses Rocha Antuniassi / Banca: Luiz Antonio Palladini / Banca: Fernando Storniolo Adegas / Doutor

Page generated in 0.0726 seconds