• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 89
  • 70
  • 12
  • 9
  • 6
  • 2
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 303
  • 303
  • 303
  • 114
  • 81
  • 69
  • 57
  • 47
  • 39
  • 35
  • 34
  • 33
  • 30
  • 26
  • 25
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
121

Ganhos ambientais e energeticos com a utilizacao da biomassa residual de gado leiteiro em Lagoa da Prata-MG / Profit environmental and energy use of biomass with residual of dairy cattle in the Lagoa da Prata - MG

OLIVEIRA, FLAVIO S. de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:28:17Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:04:04Z (GMT). No. of bitstreams: 0 / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
122

Aplicação da quimiometria para caracterização química de combustíveis tipo MTR por fluorescência de raios X / Chemometrics application in fuel's MTR type chemical characterization by x-ray fluorescence

SILVA, CLAYTON P. da 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:35:27Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:05:40Z (GMT). No. of bitstreams: 0 / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
123

Determinação de cobre, cromo e arsênio em madeira preservada (Eucalyptus sp.) pelas espectrometrias de fluorescências de raios X / Cu, Cr and As determination in preserved woods, Eucaliptus ssp, by x-ray fluorescence spectrometries

PEREIRA JUNIOR, SERGIO M. 17 March 2015 (has links)
Submitted by Claudinei Pracidelli (cpracide@ipen.br) on 2015-03-17T10:55:16Z No. of bitstreams: 0 / Made available in DSpace on 2015-03-17T10:55:16Z (GMT). No. of bitstreams: 0 / Dissertação (Mestrado em Tecnologia Nuclear) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
124

Identificação de elementos traço em tumores de mama de cadelas e sua correlação com histopatologia e prognóstico de vida /

Sakamoto, Silmara Sanae. January 2011 (has links)
Resumo: O papel dos elementos traço em tumores mamários tem sido investigado nas últimas décadas, mas comparações de subclasses de tumores mamários malignos são ainda inéditas em medicina veterinária. Portanto, o objetivo do presente trabalho foi identificar a concentração dos elementos cálcio, ferro, cobre e zinco em neoplasias mamárias de cadelas, comparando-se um grupo controle com três tipos histológicos malignos. Cinquenta e uma biopsias mamárias foram avaliadas e divididas em quatro grupos (G1 - controle, G2 - carcinoma complexo, G3 - carcinoma tubular/tubulopapilífero e G4 - carcinoma sólido). O material foi colhido de mastectomias realizadas na rotina do Hospital Veterinário da UNESP-Araçatuba sendo classificado segundo os critérios diagnósticos propostos pela Organização Mundial de Saúde. As amostras foram analisadas, quanto aos elementos traço, pela técnica de Fluorescência de Raios X por Dispersão de Energia (EDXRF). A análise estatística revelou aumento significativo (p<0,05) dos elementos cálcio, ferro e zinco entre os grupos G1 e G2. Comparações entre o sistema TNM (Tumor/Linfonodo/Metástases) e os elementos traço não foram significativas (p˃0,05) à análise estatística, já que os mesmos demonstraram estar correlacionados ao tipo histológico e não ao sistema TNM de prognóstico de vida. O aparelho de EDXRF mostrou-se eficaz para a análise dos elementos traço, além de ser uma técnica mais acessível, multielementar e não destrutiva, permitindo que outras metodologias possam ser utilizadas para estudos complementares com as mesmas amostras / Abstract: The role of trace elements in breast cancer has been investigated in recent decades, but comparisons of subclasses of malignant mammary tumors are still unpublished in veterinary medicine. So, the aim of this work was to identify the concentration of calcium, iron, cooper and zinc in canine mammary tumors, comparing them with a control group and three malignant neoplasias. 51 mammary fragments of biopsies were analyzed and divided in four groups (G1 - Control, G2 - Complex Carcinomas, G3 - Tubular/Tubulopapillary Carcinoma and G4 - Solid Carcinoma). Samples of the tumors were collected during surgical procedures, mastectomy, performed at Veterinary Hospital of Sao Paulo State University - Araçatuba and were classified according to the diagnostic criteria proposed by the World Health Organization. Samples were analyzed by Energy Dispersive X-Ray Fluorescence Equipment (EDXRF). Statistical analysis revealed a significant difference (p<0.05) only in the groups G1 and G2, concerning to the calcium, iron and zinc elements. The comparison between TNM system and trace elements revealed an absence of statistical evaluation, because trace elements were connected with histopathologycal graduation. The EDXRF was useful for trace element analyses and it is a non-destructive, multielementar technology that permits complementary studies with the same samples / Orientador: Alexandre Lima de Andrade / Coorientador: Maria Cecília Rui Luvizotto / Coorientador: Andrea Antunes Pereira / Banca: Flávia de Rezende Eugênio / Banca: Paula Rahal / Mestre
125

Caracterização de um sistema de fluorescência de raios X por dispersão em energia para análise quantitativa de ligas metálicas / Characterization of a system for X-ray fluorescence energy dispersion for quantitative analysis of metal aeloys

Rafaela Tavares Batista 27 September 2012 (has links)
Neste trabalho são apresentados os procedimentos de caracterização de um sistema comercial portátil de Fluorescência de Raios X por dispersão em energia, o ARTAX 200, bem com seu processo de calibração. O sistema é composto por um tubo de Raios X, com anodo de Molibdênio e um detector XFlash (Silicon Drift Detector) refrigerado por Efeito Peltier. O procedimento de caracterização do sistema foi realizado utilizando-se uma amostra de referência contendo Ferro e Cromo. Foram também usadas amostras certificadas (National Bureau of Standards) D840, D845, D846, D847 e D849 para a realização do processo de calibração do sistema para análise quantitativa. O processo de calibração foi realizado por três metodologias diferentes a fim de avaliar qual deles apresentaria melhores resultados. A caracterização do sistema ARTAX 200 foi realizada executando testes de estabilidade do tubo de Raios X, repetibilidade, reprodutibilidade, resolução em energia do sistema, levantamento da curva de limite de detecção e verificação do centro geométrico do feixe (CG). Os resultados obtidos nos testes de estabilidade apresentaram um coeficiente de variação médio menor do que 2%, o teste de repetibilidade apresentou valores médios menores que 0,5 %. A reprodutibilidade apresentou um coeficiente de variação médio menor que 1,5%. A verificação do centro geométrica mostrou que o CG encontra-se alinhada com o centro ótimo do feixe em duas das três direções do plano cartesiano. A resolução em energia do sistema para a energia de 5,9 keV foi de 150 eV. O limite de detecção apresentou valores menores que 1 % do Si ao Cu. Na avaliação das metodologias para calibração verificou-se que uma das metodologias aplicadas apresentou melhor resultado. Comparando os resultados com outros sistemas portáteis de XRF observa-se que o ARTAX 200 apresenta eficiência superior em relação aos parâmetros analisados. / This paper presents procedures for characterization of a commercial system for portable X-Ray Fluorescence energy dispersive, the ARTAX 200, along with its calibration process. The system consists of an X-ray tube with molybdenum anode and a Silicon Drift Detector XFlash cooled by Peltier effect. The procedure for the characterization of the system was conducted using a reference sample containing Iron Chromium. We also used the certified samples (National Bureau of Standards) D840, D845, D846, D847 and D849 to perform the calibration of the system. The calibration process was conducted by three different methods: Methodology 1, Methodology 2 and Methodology 3, to evaluate them which present better results. The characterization system ARTAX 200 was performed by running stability tests of the X-ray tube, repeatability, reproducibility, resolution in energy of the system, limit of detection and verification of the geometric center of the beam. The results of the stability tests showed an average coefficient of variation of less than 2% repeatability test showed average values lower than 0.5%. The reproducibility showed a coefficient of variation of less than 1.5% which. The verification of the geometric center is aligned with the center of the great beam in two of the three directions of the Cartesian plane. The energy resolution of the system presented to the energy of 5.9 keV a resolution of 150 eV. The detection limit values were less than 1% of the Cu Si. In evaluating methodology for calibrating the best result was obtained with the methodology 3. Comparing the results with other portable XRF systems shows that the ARTAX 200 presents superior efficiency with respect to the parameters analyzed.
126

Papel dos elementos-traço em neoplasias mamárias: estudo através de técnicas espectroscópicas de fluorescência de raios X e análises imunohistoquímicas / Role of trace elements in breast cancer: Study by X-Ray Fluorescence spectroscopy techniques and Immunohistochemical analysis.

Marina Piacenti da Silva 23 September 2011 (has links)
Neste trabalho foi avaliado o papel de elementos-traço em tecidos mamários neoplásicos e seu potencial como marcadores tumorais e fatores prognósticos. As concentrações dos elementos cálcio, ferro, cobre e zinco em tecidos normais e neoplásicos foram determinadas através de técnicas de fluorescência de raios X por dispersão por energia e por reflexão total. Modelos diagnósticos (análise de discriminante e curvas ROC - Receiver Operating Characteristic) baseados na análise estatística das distribuições de concentrações dos elementos mostraram que é possível classificar os diversos tipos de tecidos mamários (normais, benignos e malignos). Foi possível ainda avaliar a expressão dos elementos-traço e correlacioná-la com dados clinicopatológicos de importância prognóstica e com a sobrevida global de pacientes com câncer de mama. Os resultados mostraram que a expressão dos elementos-traço pode ser utilizada como marcador tumoral e fator prognóstico. Através da técnica de micro fluorescência de raios X, as distribuições espaciais dos elementos-traço foram avaliadas e comparadas com a expressão imunohistoquímica de metaloproteinases de matriz (MMPs), seus inibidores (TIMPs) e com o fator de crescimento vascular endotelial (VEGF). Os resultados mostraram que os elementos Fe, Cu e a expressão do VEGF estão correlacionados, sugerindo que o acúmulo destes elementos pode estar associado ao processo angiogênico em neoplasias mamárias. Foram observadas ainda correlações entre as distribuições de Ca, Zn e a expressão de MMPs e TIMPs, possivelmente devido à presença destes metais nestas proteínas. / In this work the role of trace elements in neoplastic breast tissues were evaluated to be applied as tumoral biomarkers and prognostic factors. Concentrations of trace elements like calcium, iron, copper, and zinc in normal and neoplastic tissues have been determinate by X-Ray Fluorescence (XRF) spectroscopic techniques. Diagnostic models (discriminant analysis and ROC curves) based on statistics analysis of trace elements concentrations distributions reveal that it is possible to classify different breast tissues (normal, benign and malignant). Also, it was possible to evaluate trace elements expression and correlate them with clinic-pathological data that are important in prognostic and the overall survival of breast cancer patients. The results presented have shown that trace elements expression can be used as tumoral biomarkers and prognostic factors. The spatial distributions of trace elements were evaluated by micro-XRF and the results were compared to immunohistochemical expression of matrix metalloproteinases (MMPs) and their inhibitors (TIMPs), as well as with vascular endothelial growth factor (VEGF). The results reveal that elements Fe, Cu and VEGF expression are correlated, indicating that the higher levels of these elements are associated with angiogenic process in breast cancer. Also, correlations between Ca, Zn and MMPs and TIMPs expression have been observed, possibly due those metals are present in these proteins.
127

Avaliação da qualidade do ar na cidade de Limeira (SP) empregando a fluorescência de raios X por reflexão total com radiação síncrotron / Evaluation of air quality in Limeira city using synchrontron radiation total reflection X-ray fluorescence analysis

Canteras, Felippe Benavente, 1987- 16 August 2018 (has links)
Orientador: Silvana Moreira / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-16T21:53:33Z (GMT). No. of bitstreams: 1 Canteras_FelippeBenavente_M.pdf: 4483858 bytes, checksum: c8bae0da36f2300a37ff6b82e1d78926 (MD5) Previous issue date: 2010 / Resumo: A preocupação de políticos, cientistas e da comunidade em geral com a qualidade do ar vem crescendo muito nos últimos anos. Isso se deve ao fato da qualidade do ar estar intimamente ligada com a qualidade de vida e a saúde da população. Os poluentes do ar estão relacionados ainda com diversos problemas ambientais, como o efeito estufa, chuvas ácidas, smog, etc. Dentre os poluentes ambientais, o material particulado se apresenta como um dos mais significativos e importantes, pois pode ser emitido por diversas fontes, sejam elas de origem antrópica ou natural, e ainda devido a não uniformidade na sua composição. O município de Limeira se apresenta atualmente como um pólo de significativo desenvolvimento e crescimento populacional. O presente trabalho teve como objetivo principal avaliar de forma quantitativa o material particulado, em suas duas frações, grossa e fina, coletado no município de Limeira. Para isso, foi instalado na estação meteorológica do CESET/UNICAMP (Centro Superior de Educação Tecnológica) um sistema de amostragem conhecido como filtração seqüencial, denominado amostrador de material particulado fino e grosso (AFG). Esse sistema foi desenvolvido pela Faculdade de Engenharia Civil, Arquitetura e Urbanismo da UNICAMP (FEC) Com este sistema pode-se obter as frações, grossa e fina, que correspondem às frações inaláveis superior e inferior, respectivamente. A técnica analítica empregada foi a Fluorescência de Raios X por Reflexão Total com Radiação Sínctrotron (SR-TXR). No período analisado, não foram registrados valores que ultrapassassem os limites previstos na legislação brasileira com relação à massa total de material particulado. Foram detectados e quantificados 16 elementos (S, K, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Br, Rb, Sr, Ba e Pb). Foram empregadas análises estatísticas multivariadas (análise dos componentes principais e análise de cluster) para agrupar os elementos de acordo com suas similaridades, e a partir disso, definir as possíveis fontes emissoras de poluentes. Na fração fina do material particulado a principal fonte de emissão foi a poeira do solo, responsável por 79% da formação do material particulado. As emissões veiculares contribuíram com 13% e, as emissões industriais representaram 8%. Para a fração grossa a fonte principal de emissão foi a ressuspensão do solo contribuindo com 57% na formação do material particulado, seguida da emissão veicular, com 30% e finalmente a industrial, com apenas 13%. Os perfis das assinaturas das fontes de emissão veicular, queima de óleo combustível e da poeira do solo foram comparadas com perfis apresentados por outros autores e de forma geral apresentaram uma boa concordância / Abstract: The concern of politicians, scientists and the wider community with the air quality has been increasing in recent years. This is because air quality is closely linked with the quality of life and health of the population. Air pollutants are associated with various environmental issues like global warming, acid rain, smog, etc. Among environmental pollutants, particulate matter is presented as one of the most significant and important since it is emitted through several sources whether anthropogenic or natural, and also due to the non-uniformity in its composition therefore it is important to quantify and verify composition. The city of Limeira is presented today as a center of significant development and population growth. This study mainly aims at assessing quantitatively the particulate material collected in the city of Limeira in its two fractions, coarse and fine. Assessment was performed using the sampling system known as Sequential Filtration installed at the CESET (Center of Technology Education- UNICAMP) weather station. This system was developed by the Engineering Civil, Architecture and Urbanism College (FEC) with the support of Synchrotron Light Source Laboratory (LNLS), named fine and coarse particles sampler (AFG). With this system you can obtain the coarse and fine fractions, corresponding to the inhalable fraction top and bottom, respectively. The analytical technique employed was Synchrotron Radiation Total Reflection X-ray Fluorescence. In the studied period was not observed values higher than the limits established by Brazilian legislation concerns to total mass of particulate matter. In this work 16 elements were detected and quantified (S, K, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Br, Rb, Sr, Ba and Pb). Statistical analysis as principal component analysis and cluster analysis were employed to group elements according their similarities in order to define the emission sources of pollutants. In the fine fraction the main emission source was soil dust responsible by 79% in the particulate matter. The vehicular emissions contributed with 13% and, industrial emissions represent 8%. The main emission source for coarse fraction was soil dust contributing with 57%, follow by vehicular emission with 30% and finally the industrial emissions with just 13%. The signature profiles of vehicular emission, burning of fuel oil and soil dust were compared with the profiles presented by other authors and in a general way show a good agreement / Mestrado / Saneamento e Ambiente / Mestre em Engenharia Civil
128

Analise quantitativa do sedimento depositado nas planicies de inundacao do rio Solimoes/Amazonas, utilizando a tecnica de fluorescencia de raios X por dispersao de energia

CARNEIRO, ANA E.V. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:38:44Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:00:08Z (GMT). No. of bitstreams: 1 06003.pdf: 11473213 bytes, checksum: 759e2030493408079cad31ae3d3dd261 (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
129

Ganhos ambientais e energeticos com a utilizacao da biomassa residual de gado leiteiro em Lagoa da Prata-MG / Profit environmental and energy use of biomass with residual of dairy cattle in the Lagoa da Prata - MG

OLIVEIRA, FLAVIO S. de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:28:17Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:04:04Z (GMT). No. of bitstreams: 0 / O objetivo deste trabalho foi investigar os ganhos ambientais e energéticos com o aproveitamento da biomassa residual de gado leiteiro no município de Lagoa da Prata-MG. Para este estudo realizaram-se trabalhos de campo, tanto para caracterizar a pecuária leiteira no município, como para conhecer os aspectos ambientais da localidade. Para se conseguirem dados de relevância energética e ambiental, visitaram-se nove fazendas da região onde os responsáveis responderam a um questionário. Recolheram-se amostras de resíduos do gado confinado em cada uma delas. Os resultados da pesquisa mostraram uma média de 3 toneladas de geração diária de biomassa residual por propriedade. Constatou-se um consumo médio de energia elétrica de 2.500 kW/h, pela utilização de uma série de equipamentos energointensivos. Encontrou-se um consumo médio de água de 27 m³/dia. Realizaram-se análises químicas por Espectrometria de Fluorescência com Raio X nas amostras de resíduos e observaram-se concentrações médias relativamente altas para os elementos P, Fe, S, Ti, Mn, Zn e Na, passíveis de comprometer o meio ambiente local e regional. Para diagnosticar os ganhos energéticos foi simulada a produção de biogás através de protótipos de biodigestores com as amostras de dejetos obtidas nas fazendas. Os resultados analíticos do biogás através de cromatografia gasosa demonstraram concentrações aproximadas de 70% de CH4 , logo concluiu-se que o biogás obtido possui alto valor energético. Portanto, a utilização dos dejetos do gado leiteiro na produção de biogás, além de resolver o problema dos resíduos, efluentes e diversas outras poluições ambientais, eventualmente geradas pela atividade na região, poderá trazer auto-suficiência energética às propriedades locais. / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
130

Aplicação da quimiometria para caracterização química de combustíveis tipo MTR por fluorescência de raios X / Chemometrics application in fuel's MTR type chemical characterization by x-ray fluorescence

SILVA, CLAYTON P. da 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:35:27Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:05:40Z (GMT). No. of bitstreams: 0 / No Brasil e no mundo a tecnologia nuclear vem ocupando posição de destaque com diversas aplicações na indústria, geração de energia, meio ambiente e na medicina, melhorando a qualidade de exames e tratamentos, consequentemente, a vida das pessoas. O urânio é o principal elemento utilizado em instalações nucleares, servindo como material base desde a geração de eletricidade à fabricação de radiofármacos. Nos anos 50, em meio à guerra fria, a então recém-criada Agência Internacional de Energia Atômica se propôs a supervisionar instalações nucleares e incentivar a fabricação de combustíveis nucleares com baixo teor de urânio, conhecidos como combustíveis do tipo Material Test Reactor (MTR), fabricados inicialmente na forma de U3O8 e mais tarde o U3Si2, ambos dispersos em alumínio. A utilização desta tecnologia requer uma constante melhoria de todos os processos que envolvem a fabricação do MTR sujeita a diversos protocolos internacionais, os quais procuram garantir a confiabilidade desse combustível do ponto de vista prático e ambiental. Dentro desse contexto, o controle de impurezas, do ponto de vista da economia de nêutrons, afeta diretamente a qualidade de qualquer combustível nuclear, fazendo-se necessário um controle rigoroso. A literatura reporta procedimentos que, além de gerar resíduos, são demorados e dispendiosos, pois necessitam de curva de calibração univariada e materiais de referência. Assim, o objetivo deste trabalho é estabelecer e validar uma metodologia de análise química quantitativa não destrutiva, de baixo custo e tempo de análise, tal como, minimizar a geração de resíduo para a determinação multielementar dos maiores constituintes (Utotal e Si) e as impurezas (B, Mg, Al, Cr, Mn, Fe, Co, Ni, Cu, Zn, Mo, Cd e outros) presentes em U3O8 e U3Si2, atendendo as necessidades de reatores nucleares na qualificação de combustíveis nucleares do tipo MTR. Para tanto, foi aplicada a técnica de fluorescência de raios X que permite análises químicas rápidas e não destrutivas, além de não necessitar de tratamentos químicos prévios (dissolução, digestão e outros) na fase de preparação de amostras. Para as correções de efeitos espectrais e de matriz foram aplicados e avaliados os métodos de parâmetros fundamentais, de curva de calibração univariada e de calibração multivariada. Os resultados foram comparados por meios de testes estatísticos em conformidade com a norma ISO 17025 com os MRCs (123(1-7) e 124(1-7)) de U3O8 da New Brunswick Laboratory (NBL) e 16 amostras de U3Si2 cedidas pelo CCN do IPEN-CNEN-SP. A quimiometria demonstrou-se um método promissor para a determinação de maiores e menores constituintes em combustíveis nuclear a base de U3O8 e U3Si2, uma vez que a precisão e exatidão são estatisticamente iguais aos métodos de análises volumétrica, gravimétrica e ICP-OES. / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP

Page generated in 0.3171 seconds