• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 62
  • 18
  • 15
  • 4
  • 2
  • 1
  • 1
  • Tagged with
  • 105
  • 105
  • 105
  • 66
  • 44
  • 38
  • 20
  • 17
  • 16
  • 15
  • 12
  • 12
  • 10
  • 9
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Avaliação do reparo tecidual em defeito ósseo por microtomografia tridimensional por raio X / Evaluation of tissue repair after bone fracture using 3D X-ray microtomography

Simone Orlandi Introini 01 July 2011 (has links)
A fratura é uma descontinuidade óssea que pode ser produzida cirurgicamente ou causada por um impacto que excede a resistência mecânica do osso dando início a uma sequência de eventos sistêmicos e específicos de resposta do tecido. Exames radiológicos são comumente realizados na clínica e em experimentos com animais para o monitoramento do reparo ósseo dando informações sobre o alinhamento dos fragmentos e da evolução de reparo. Outras técnicas de monitoramento qualitativas e quantitativas podem ser utilizadas em experimento animal (histologia e ensaios mecânicos) e em experimento animal e clínico (tomografia computadorizada por raio X, ressonância magnética, ultra-sonografia). A microtomografia 3D por raio X é uma nova técnica de monitoramento para uso em experimento animal e com grande potencialidade. A quantificação do reparo ósseo com novas metodologias tem larga aplicação em investigações sobre técnicas invasivas e não-invasivas de tratamento de fraturas utilizando-se experimento animal. O objetivo dessa investigação foi a utilização da microtomografia 3D por raio X policromático (\'mü\'CT) para a avaliação do reparo ósseo em defeito ósseo na tíbia direita de rato macho da raça Wistar com peso aproximado de 280 g. O defeito foi produzido por uma broca odontológica com alta rotação. Foram estabelecidos quatro grupos experimentais caracterizados pela utilização ou não utilização do tratamento do defeito por ultra-som pulsado de baixa intensidade (LIPUS, 30 mW/\'CM POT.2\') e pela duração do experimento. No grupo 1 o tratamento por ultra-som teve a duração de 14 dias, 5 sessões de tratamento por semana. No grupo 2 não houve tratamento por ultra-som e a duração foi de 14 dias. No grupo 3 o tratamento por ultra-som teve a duração de 21 dias, 5 sessões de tratamento por semana. No grupo 4 não houve tratamento por ultra-som e a duração foi de 21 dias. Nos grupos 1 a 4 foram utilizados 10 animais para a avaliação por CT. O defeito ósseo da tíbia direita nos animais dos grupos 1 e 3 foi tratado com ultra-som de baixa intensidade. A avaliação por CT foi realizada através dos softwares NRecon, Data Viewer , CT-Analyzer e CT-Vol fornecidos pelo fabricante do microtomógrafo (Skyscan, Bélgica). Não foi observada diferença estatísticamente significante na quantificação do reparo ósseo dos defeitos dos grupos 1 e 2 e dos grupos 3 e 4. / Fracture is a bone discontinuity that can be surgically produced or caused by an impact that exceeds the mechanical strength of bone by initiating a series of systemic events and specific tissue response. Radiological tests are commonly performed in clinical and animal experiments for monitoring the bone healing by providing information about the alignment of the fragments and the evolution of repair. Other techniques for monitoring quality and quantity can be used in experimental animals (histology and mechanical tests) and in animal experiments and clinical studies (computed tomography X-ray, MRI, ultrasound). The 3D microtomography by X-ray is a new monitoring technique for use in animal experiment and with great potential. The quantification of bone repair with new methods has wide application in research on invasive and noninvasive treatment of fractures using animal experiment. The goal of this research was to use the 3D microtomography by non monochromatic X-ray (\'mü\'CT) to evaluate the bone healing in bone defect in the tibia of Wistar male rat weighing approximately 280 g. The defect was produced by a dental drill with high speed. It was established four experimental groups characterized by the use or non use of low intensity pulsed ultrasound (LIPUS, 30 mW/\'CM POT.2\') for the bone defect treatment as well as the duration of the experiment. In group 1 the LIPUS treatment last 14 days, 5 treatment sessions per week. In group 2 the LIPUS treatment was not used and the duration was 14 days. In group 3 the LIPUS treatment last 21 days, 5 treatment sessions per week. In group 4 the LIPUS treatment was not used and the duration was 21 days. In groups 1 to 4, 10 animals were used for evaluation by CT. The evaluation was conducted by CT through software NRecon, Data Viewer, CT-Vol and CT-Analyzer supplied by the microtomography manufacturer (SkyScan, Belgium). No significant statistical differences were found between the results of groups 1 and 2 as well as the results of groups 3 and 4.
22

Efeito da Interação Entre o Flúor e a Irradiação com Lazer Nd: YAG na Prevenção de Desmineralização IN VITRO

Gomes, Angelinne Ribeiro Angelo 14 August 2015 (has links)
Submitted by Fabio Sobreira Campos da Costa (fabio.sobreira@ufpe.br) on 2016-05-19T15:10:35Z No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) TESE ANGELINNE UFPE final.pdf: 3581361 bytes, checksum: 1339333592e5d5e1f75e70ed7c727620 (MD5) / Made available in DSpace on 2016-05-19T15:10:35Z (GMT). No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) TESE ANGELINNE UFPE final.pdf: 3581361 bytes, checksum: 1339333592e5d5e1f75e70ed7c727620 (MD5) Previous issue date: 2015-08-14 / Introdução. Esforços têm sido direcionados para a redução do risco à cárie dentária através da adoção de medidas preventivas e motivacionais. Evidências recentes apontam que a irradiação com laser é eficaz no aumento da resistência dentária à desmineralização promovida durante o processo cariogênico. No entanto, ainda não há um consenso quanto a melhor forma de uso clínico do laser. Objetivos. Este estudo visou avaliar, num modelo in vitro, o efeito da interação entre e a irradiação do laser Nd:YAG com um verniz de flúor na prevenção da desmineralização do esmalte dentário. Materiais e Métodos. Cento e dez espécimes de esmalte foram distribuídos em 5 grupos, a saber: Grupo 1 – Controle, Grupo 2 – Flúor, Grupo 3 – Laser, Grupo 4 – Flúor/Laser e Grupo 5 – Laser/Flúor. Os grupos 3,4 e 5 foram subdivididos em 3 subgrupos cada de acordo com as potências utilizadas (0,5, 075 e 1W), totalizando 11 grupos com 10 espécimes cada. Os tratamentos superficiais consistiram no uso do laser Nd:YAG e verniz fluoretado isolados e em associação, seguido de um processo de desmineralização in vitro por 48 horas. Em sequência, as amostras foram escaneadas em um microtomógrafo de raios–X (XTEK XT-H 225 ST microfocos) e as imagens obtidas foram reconstruídas e processadas para quantificar a perda mineral e a diferença de densidade mineral entre as áreas exposta e não-exposta do esmalte dentário. Resultados. O grupo 1 apresentou maior perda mineral (89,8 ± 24,6μm) (p<0,001). Amostras tratadas com flúor apresentaram perda mineral semelhante aos grupos tratados com laser e associações de laser flúor (p>0,05). A diferença de densidade mineral do esmalte apresentou-se maior no grupo 1 (1.756 ± 746HU) (p<0,001). O uso isolado do flúor e os tratamentos laser/flúor demonstraram as menores médias na variação da densidade. Conclusões. O uso exclusivo do laser e suas associações com o verniz fluoretado mostraram-se semelhantes ao uso exclusivo do flúor. A associação do verniz fluoretado com o laser apresenta melhor performance quando o laser Nd:YAG é utilizado previamente ao verniz. / Introduction. Efforts have been directed to reducing the risk of caries adopting preventive and motivational measures. New found evidence suggests that the laser irradiation is effective in increasing the resistance to tooth demineralization promoted during the cariogenic process. However, there is still no consensus on the best way of laser clinical use. Objectives. This study aimed to evaluate an in vitro model, the effect of interaction between the radiation and the Nd:YAG laser with a fluoride varnish on the prevention of demineralization of dental enamel. Materials and methods. One hundred and ten enamel specimens were distributed into 5 groups as follows: Group 1 - Control, Group 2 - Fluoride, Group 3 - Laser, Group- 4 - Fluoride/Laser, Group 5 - Laser /Fluoride. Groups 3,4 and 5 were each subdivided into 3 subgroups according to the power (0.5, 075, and 1W), a total of 11 groups of 10 specimens each. The surface treatment consisted in the use of Nd: YAG laser and fluoride varnish isolated and in combination, followed by a process of demineralization in vitro for 48 hours. In the following, the specimens were scanned at a X-ray microtomography (XT-H Xtek microfocus ST 225) and images were reconstructed and processed to quantify the mineral loss and the mineral density difference between the exposed and non-exposed areas enamel. Results. Group 1 showed higher mineral loss (89.8 ± 24,6μm) (p <0.001). Samples treated with fluoride mineral loss showed similar to the groups treated with laser and Fluorine laser associations. The difference mineral density was higher in Group 1 (1.756 ± 746HU) (p <0.001). The isolated use of fluoride and treatments laser/fluoride promoted smaller mean of density. Conclusions. The exclusive use of laser and their association with fluoride varnish were similar to the exclusive use of fluoride. The association of fluoride varnish with laser shows better performance when the Nd: YAG laser is first used to varnish.
23

Efeito do LED infravermelho sobre a movimentação dentária induzida em ratos / Infrared LED phototherapy effects on induced tooth movement in rats

Simone Peixe Friedrichsdorf 14 August 2015 (has links)
O LED infravermelho tem sido considerado uma alternativa efetiva para o laser na bioestimulação. Entretanto, o efeito na remodelação óssea durante o movimento ortodôntico ainda deve ser esclarecido. Oitenta ratos machos com 10 semanas de idade, foram divididos em dois grupos de 40 animais cada: grupo LED (GLED) e grupo controle (GCON), e tiveram seu 1ºmolar superior esquerdo submetido a força de 10 g com uma mola helicoidal fixada entre o 1ºmolar superior esquerdo e incisivo superior esquerdo. Durante os primeiros cinco dias de movimentação dentária foi aplicada a luz infravermelha LED (850nm, 30mW) durante 5 minutos no GLED. O GCON não foi irradiado. Em 0, 7, 14 e 21 dias, 5 animais de cada grupo foram submetidos a microtomografia computadorizada. Para a avaliação histológica, todos os ratos foram subdivididos em subgrupos de 20 animais cada de acordo com a o dia da eutanásia 4, 7, 14 e 21 dias e as maxilas foram dissecadas e processadas para a microscopia de luz (HE e TRAP). A quantidade de movimento, segundo as microtomografias computadorizadas, foi maior no grupo LED em T1 (intervalo entre os dias 0 e 7) e em T3 (intervalo entre os dias 14 e 21). No dia 4 foi observada hialinização na área de pressão em ambos os grupos; nos períodos posteriores, 7, 14, a área hialina foi vista apenas no grupo controle. A reabsorção radicular ocorreu em ambos os grupos após o dia 7. A fototerapia LED melhora a movimentação dentária e minimiza a hialinização durante o movimento ortodôntico. Entretanto, não reduz o risco de reabsorção da superfície radicular. / Infrared LED has been considered an effective alternative to infrared LASER for biostimulation purposes. However, its effect on bone remodeling during orthodontic tooth movement (OTM) is unknown. Eighty 10 week-old male Wistar rats were divided into two groups of forty animals each: LED group (GLED) and control group (GCON) and had a coiled spring bonded to the first upper molar and upper incisor exerting 10g force to mesially move the molar. During the first five days of OTM the maxillae were daily irradiated with infrared LED (850nm, 30mW) during 5 minutes (LED group). The controls were not irradiated (GCON). At 0, 7, 14 and 21 days, 5 LED group and 5 CON group rats were submitted to ?CT. For the histological study, all rats were subvided into subgroups of 20 animal each according to the euthanasia day 4, 7, 14 e 21 days. The rats were euthanized after 4, 7, 14 and 21 days and the maxillae were processed to light microscopy and TRAP histochemistry. The amount of tooth movement was greater in the GLED on days 7 and 14. At 4 day, hyalinization was seen at the pressure areas in both groups; on the subsequent days it was seen only in the GCON. Root resorption occurred in both groups after 7 days. LED phototherapy enhances early tooth movement and minimizes periodontal hyalinization during OTM. However, it does not reduce the risk of tooth resorption.
24

Análise ex vivo de cortes apicais de dentes humanos em 3D empregando microtomografia computadorizada / Ex vivo analysis of apical human tooth in 3D sections using computed micro-CT

Marcia Regina Ramalho da Silva Bardauil 08 July 2010 (has links)
O objetivo deste estudo in vivo foi investigar as imagens obtidas por microtomografia computadorizada (micro-TC) no estudo da anatomia apical de dentes humanos portadores de polpa viva e mortificada. Trinta e cinco dentes humanos unirradiculares ou multirradiculares que tiveram suas raízes separadas totalizando quarenta e uma raízes foram rigorosamente pré-selecionadas e divididas em dois grupos: com polpa viva (PV) n = 21 e com polpa mortificada (PM) n = 20. Os dentes de ambos os grupos foram escaneados pelo sistema de microtomografia computadorizada (SkyScan 1172) com resolução de 6,7m e suas imagens reconstruídas para a análise da região apical nos cortes sagital e coronal. O diâmetro do forame apical (FA) e da junção cemento-dentina (JCD) foram medidos bem como suas distâncias (extensão do cemento) em ambos os lados da raiz. Posteriormente a coroa dos dentes foi cortada no seu colo anatômico e suas raízes foram medidas com paquímetro eletrônico e a odontometria realizada com localizador eletrônico apical (RomiApex A15). A subtração desses dois dados foi correlacionada com as medidas obtidas pela micro-TC na avaliação da posição da JCD. As raízes foram preparadas para avaliação histológica em cortes longitudinais de 6m de espessura e corados com HE. Os cortes que apresentaram a emergência do FA foram fotografados digitalmente e as imagens correspondentes de micro-TC foram sobrepostas com o intuito de ilustrar a metodologia utilizada. As medidas da micro-TC foram realizadas por dois examinadores devidamente instruídos. A concordância inter-examinadores foi confirmada pelo coeficiente de correlação intraclasse (ICC) e as medidas foram comparadas pelo teste de Mann-Whitney (teste de Wilcoxon rank sum - p0,05). Os resultados indicaram que não houve diferença estatisticamente significante quanto à extensão do cemento intrarradicular nos grupos quer de polpa viva como mortificada com distâncias de 0,32±0,1mm e 0,36±0,16mm respectivamente. As medidas realizadas pelo localizador apical, a 1,0mm aquém, garantiu o estabelecimento do limite dentro do canal dentinário. Os resultados encontrados para o diâmetro do forame apical foi 619,32±32 m para o grupo PV e 630,542±140,99m para o grupo PM sem diferença estatisticamente significante. O diâmetro do canal radicular na junção cemento-dentina não apresentou diferença estatisticamente significante entre PV com 330,37±126,62m e PM com 357,62±996,14m. O posicionamento da JCD em relação ao FM não foi influenciado pelo estado de vitalidade pulpar. / This ex vivo study aimed to investigate the apical anatomy of vital and necrotic human roots by microcomputed tomography (micro-CT). Thirty-five single or multirooted human teeth that had their roots separated totaling forty-one roots were carefully pre-selected and divided into two groups: vital pulp (VP) n = 21 and necrotic pulp (NP) n = 20. Both groups were scanned by microcomputed tomography system (SkyScan 1172) with 6.7m resolution and the apical region was analyzed by reconstructed images in sagittal and coronal sections. The diameters of the apical foramen (AF) and root canal at the cemento-dentino canal junction (CDJ) were measured. The cementum extension into the root canal was measured on both sides of the root canal. Thereafter the teeth crown was cut at the cemento-enamel junction, the length of roots was measured with a caliper and the working length was performed by an electronic apex locator (RomiApex A15). The result of the subtraction of these two data was correlated with measures obtained by micro-CT in the evaluation of CDJ position. The roots were sectioned in longitudinal histological sections of 6m thickness and stained with HE. The sections that showed the emergence of the FA were digitally photographed and the corresponding micro-CT sections were correlated by superimposition in order to illustrate the methodology. Measures of micro-CT scans were performed by two calibrated examiners. The interexaminers agreement was confirmed by intraclass correlation coefficient (ICC) and measurements were compared by Mann-Whitney test (Wilcoxon rank sum test - p0.05). The results indicated that there was no statistically significant difference in relation to the extension of cementum into the root canal in both goups VP or NP with average distances of 0.32±0.1mm and 0.36±0.16mm respectively. The measurements taken by the apex locator 1 mm from the apex were within the limits of dentinal canal. The diameter of the apical foramen corresponded to the NP group was 619.32±201.61m and 619.32±140.99m on average, not statistically significant. The average diameter of the root at the CDJ was 330.37±126.62m for VP and 357.62 ±96.14m for NP groups presenting no statistically significant difference. The distance of the CDJ in relation to AF was not influenced by the pulp vitality.
25

Avaliação da microarquitetura e resistência óssea em ratos submetidos à dieta diária de café e refrigerantes à base de cola e guaraná : Evaluation of microarchitecture and bone resistance in mice with daily diet of coffe and soft drinks based in coke and guarana / Evaluation of microarchitecture and bone resistance in mice with daily diet of coffe and soft drinks based in coke and guarana

Silva, Amaro Ilídio Vespasiano, 1985- 24 August 2018 (has links)
Orientador: Lourenço Correr Sobrinho / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-24T19:04:20Z (GMT). No. of bitstreams: 1 Silva_AmaroIlidioVespasiano_D.pdf: 825243 bytes, checksum: 348fd72cdb122213d969293a350a2f66 (MD5) Previous issue date: 2014 / Resumo: O objetivo neste estudo foi investigar e comparar os efeitos da dieta de café e refrigerantes à base de cola e guaraná sobre a microarquitetura e resistência óssea em ratos. Foram utilizados 80 ratos (Rattus norvegicus, Albinus Wistar), sendo 40 machos e 40 fêmeas, distribuídos em 8 grupos experimentais que receberam água (grupos controles), refrigerantes à base de cola, guaraná e café ad libitum. Ao término dos 48 dias de administração das substâncias, todos os animais foram sacrificados e o fêmur direito coletado para análise por microtomografia computadorizada e ensaio de resistência à flexão de três pontos. Após tabulação dos dados e análise estatística (ANOVA), foi observado alteração na microarquitetura óssea nos seguintes parâmetros analisados pela microtomografia computadorizada: volume de tecido (TV), volume ósseo (BV), superfície de tecido (TS), superfície óssea (BS), número de trabéculas ósseas (Tb.N), espessura das trabéculas ósseas (Tb.Th), volume de poros fechados (Po.V(cl)) e Volume de poros abertos (Po.V(op)) além de alterações na resistência óssea nas fêmeas. Concluiu-se que A ingestão das substâncias avaliadas causou alteração na microarquitetura óssea, levando a um aumento dos parâmetros de volume, tanto ósseo quanto de tecido. Porém, o consumo de refrigerante à base de guaraná e de café reduziram a microarquitetura trabecular; além disso, a ingestão de café e de refrigerante à base de cola aumentou o risco à fratura óssea nas fêmeas / Abstract: The aim of this study was to investigate and compare the effects of daily diet of coffee and soft drinks based in coke and guarana over the microarchitecture and bone strength in rats. 80 rats ( Rattus norvegicus, Albinus Wistar ) were used, 40 males and 40 females, divided into 8 experimental groups that received water (control groups), coke and guarana and coffe ad libitum. At the end of the 30 days of administration of substances, all animals were sacrificed and the right femur collected for analysis by computerized microtomography and testing flexion module of three points. After tabulating the data and statistical analysis (ANOVA), was observed changes in the bone microarchitecture in the following parameters assessed by computed microtomography: tissue volume (TV), bone volume (BV), tissue surface (TS), bone surface (BS), trabecular number (Tb.N), trabecular thickness (Tb.Th), volume of closed pores (Po.V(cl)) and volume of open pores (Po.V(op)), also changes in bone strength in females . It was concluded that ingestion of substances evaluated caused change in bone microarchitecture, leading to an increase in volume parameters, both bone as tissue. However, the consumption of coolant based on guarana and coffee reduced trabecular microarchitecture; Furthermore, ingestion of coffee and cola soft drink to increased risk of bone fracture in females / Doutorado / Radiologia Odontologica / Doutor em Radiologia Odontológica
26

Release behaviour of single pellets and internal fine 3D structural features co-define the in vitro drug release profile

Yang, S., Yin, X., Wang, C., Li, H., He, Y., Xiao, T., Sun, L., Li, J., York, Peter, He, J., Zhang, J. January 2014 (has links)
No / Multi-pellet formulations are advantageous for the controlled release of drugs over single-unit dosage forms. To understand the diffusion controlled drug release mechanism, the pellet structure and drug release from a single pellet (not at dose level) were studied using synchrotron radiation X-ray computed microtomography (SR-muCT) and a sensitive LC/MS/MS method. The purpose of this article is to introduce a powerful, non-invasive and quantitative technique for studying individual pellet microstructures and to investigate the relationship between the microstructure and drug release from single pellets. The data from the single pellet dissolution measurements demonstrated that the release profile of capsules containing approximately 1,000 pellets per unit dose was the summation of the release profiles of the individual pellets. The release profiles of single tamsulosin hydrochloride (TSH) pellets formed three groups when a cluster analysis was performed, and the dissolution rate of the individual pellets correlated well with the combined effects of the drug loading, volume and surface area of the pellets (R(2) = 0.9429). In addition, the void microstructures within the pellet were critical during drug release. Therefore, SR-muCT is a powerful tool for quantitatively elucidating the three-dimensional microstructure of the individual pellets; because the microstructure controls drug release, it is an important parameter in the quality control of multi-pellet formulations.
27

Characterizing Non-Wetting Fluid in Natural Porous Media Using Synchrotron X-Ray Microtomography

Narter, Matthew January 2012 (has links)
The objective of this study was to characterize non-wetting fluid in multi-phase systems comprising a range of fluid and porous medium properties. Synchrotron X-ray microtomography was used to obtain high-resolution, three-dimensional images of fluids in natural porous media. Images were processed to obtain quantitative measurements of fluid distribution, morphology, and interfacial area. Column-flooding experiments were conducted with four enhanced-solubilization (ES) solutions to examine their impact on entrapped organic liquid. Mobilization caused a change in organic-liquid morphology and distribution for most experiments. The effect of ES-solution flooding on fluid-fluid interfacial area was similar to that of water flooding. Organic-liquid mobilization was observed at total trapping numbers that were smaller than expected. This was attributed to pore-scale mobilization of blobs that were re-trapped prior to being eluted from the column. Pore-scale mobilization was also observed during water-flooding experiments for which trapping numbers varied over several orders of magnitude. Water-flooding and surfactant-flooding experiments were compared to investigate the impact of interfacial tension, viscosity, and fluid velocity on entrapped organic liquid. For similar total trapping numbers, flooding at larger velocities appeared to have a greater effect on the distribution of non-wetting blobs than lowering interfacial tension or increasing the viscosity of the wetting fluid. The fluid-normalized interfacial area was generally independent of the total trapping number. Finally, the impact of fluid type on the interfacial area between different pairs of non-wetting fluids was investigated during drainage and imbibition in four natural porous media. Interfacial areas were similar among all fluid pairs for a given porous medium. They were also similar for drainage and imbibition conditions. The maximum specific interfacial area (A(m)) was determined to quantify the magnitude of interfacial area associated with a given porous medium. The value of A(m) was larger for the media with smaller median grain diameters. Therefore, physical properties of the porous medium appear to have a greater influence on the magnitude of specific total interfacial area for a given saturation than fluid properties or wetting-phase history.
28

Avaliação da plataforma tri-channel por meio de microtomografia computadorizada e suas propriedades mecânicas após torque de inserção, fadiga e fratura / Tri-channel platform evaluation by computerized microtomography and its mechanical properties after insertion torque, fatigue and fracture

Morais, Renata Costa de 26 October 2018 (has links)
Para avaliação das propriedades físico-mecânicas de implantes tri-channel Dérig, quanto ao efeito de acréscimo de 0,25mm no corpo do implante 3.5 NP (em relação ao controle 3.5 NP) e à influência da plataforma switching (em diâmetros iguais de 4,3 mm e plataformas distintas - NP e RP), o presente estudo relacionou resistência ao torque de inserção (avaliação do microgap entre implante/pilar protético - mensurações bi e tridimensionais), em microtomografia computadorizada (CT); resistência à fratura e resistência à fadiga. Para a resistência ao torque de inserção, os implantes foram divididos, aleatoriamente, em quatro subgrupos (n=10), segundo torque: GT45: 45 N.cm; GT80: 80 N.cm; GT120: 120 N.cm; GT150: 150 N.cm. Os conjuntos implante/pilar/parafuso foram levados às análises de deformação bi e tridimensional em CT. Para o teste de resistência à fratura, os conjuntos implantes/munhões foram levados à máquina de ensaios universais, até a falha e, posteriormente, às microscopias óptica e eletrônica de varredura. Para a resistência à fadiga, os conjuntos (n=12) foram submetidos a ensaio cíclico (5 Hz, 5° - 55° C, cargas em 80, 120, 160, 200, 240, 280 e 320 N, máximo de 2x104 ciclos) e carregados até a falha (ou máximo de 14x104 ciclos) (análise de sobrevivência Life Table Survival Analysis). Para o envelhecimento mecânico, os conjuntos (n=12) foram submetidos a 106 ciclos (2 Hz, 120 N, 5º - 55º C) e, novamente, levados às análises microscópicas. Após a análise estatística (2-way ANOVA, Bonferroni, p<0,05), para a análise da porcentagem de deformação bi e tridimensional dos torques de inserção em CT, há diferenças significantes (p<0,05) em todas as comparações, à exceção de 4.3 NP x 4.3 RP (45N). As microtomografias evidenciaram microgaps em conjuntos novos e aumento, qualitativo, dos mesmos, em diâmetros e plataformas menores. A comparação linear com conjuntos novos demonstrou diferenças significantes (p<0,05) em 3.5 NP e 3.75 NP (todos os torques) e 4.3 NP (120 e 150 N.cm). Para o ensaio de resistência à fratura (1-way ANOVA, Tukey B, p<0,05), 4.3 NP apresentou força máxima de deformação maior (p<0,05) que 3.75 NP e 3.5 NP (p=0,004), mas não houve diferença significante entre 4.3 RP, 3.5 NP e 3.75 NP (p>0,05). Quanto aos ensaios de resistência à fadiga, o envelhecimento mecânico levou ao afrouxamento dos parafusos de todos os grupos analisados, sendo que, à exceção de 3.75 NP, houve diferenças significativas (p<0,05) entre perdas de torques inicial e final; para a fadiga acelerada, ambos os grupos de 4,3 mm (NP e RP) sobreviveram ao final do ensaio, sendo que houve fratura de todas as amostras de 3.5 NP. Finalmente, quanto à probabilidade de sobrevivência, houve diferença significante (p<0,05) entre 3.5 NP e 3.75 NP, com taxa de 92% para este último. Conclui-se que o diâmetro 4,3 mm é mais resistente que 3,5 mm; 4.3 NP apresentou maior resistência à fratura; o envelhecimento mecânico leva à perda de torque; a fadiga mecânica acelerada tem influência em diâmetros menores e a metodologia em CT é válida para análises bi e tridimensional / To investigate the physical-mechanical properties of Dérigs tri-channel implants, regarding the 0.25 mm addition in 3.75 NP implant structure (in relation to 3.5 NP as control) and the influence of platform switching (in equal diameters of 4.3 mm and different platforms - Narrow and Regular), this study related the resistance to insertion torque (microgap evaluation between implant and abutment - bi and tridimensional measurements), computerized microtomography (CT); resistance to fracture and fatigue. For the resistance to insertion torque, the samples were randomly divided into four subgroups (n=10), according to the torque applied: GT45: 45 N.cm; GT80: 80 N.cm; GT120: 120 N.cm; GT150: 150 N.cm. The implant/abutment/screw assemblies were taken to bi and tridimensional deformation analyzes in CT. For the fracture strength test, the implant/abutment assemblies were taken to the universal test machine until failure and then to optical and scanning electron microscopes. For the fracture resistance, the sets (n=12) were subjected to a cyclic test (5 Hz, 5° - 55° C, loads in 80, 120, 160, 200, 240, 280 and 320 N, maximum of 2x104 cycles) and loaded to failure (or maximum of 14x104 cycles) (Life Table Survival Analysis). For mechanical aging, the sets (n=12) were submitted to 106 cycles (2 Hz, 120 N, 5º - 55º C) and, again, to microscopic analysis. After statistical analysis (2-way ANOVA, Bonferroni, p<0.05), there were statistical differences (p<0.05) in all comparisons for the bi and three-dimensional deformation percentages of the insertion torques in CT, except between 4.3 NP x 4.3 RP (45N). The microtomographies evidenced microgaps in new sets and a qualitative increase of the same sets in diameters and smaller platforms. The linear comparison with new sets showed significant differences (p<0.05) in 3.5 NP and 3.75 NP (all torques) and 4.3 NP (120 and 150 N.cm). As for the fracture resistance test (1-way ANOVA, Tukey B, p<0.05), 4.3NP had a higher maximum deformation force (p<0.05) than 3.75 NP and 3.5NP (p=0.004), but there was no significant differences between 4.3 RP, 3.5 NP and 3.75 NP (p>0.05). Regarding the fatigue strength tests, the mechanical aging led to the screw loosening of all groups analyzed, and by the exception of 3.75 NP, there were significant differences (p<0.05) between initial and final torque applied; for the accelerated fatigue, both groups of 4.3 mm (NP and RP) survived at the end of the test, with fractures in all 3.5 NP samples. Finally, regarding the survival rate, there was a significant difference (p<0.05) between 3.5 NP and 3.75 NP, with a 92% rate for this last one. It could be concluded that the diameter 4.3 mm is stronger than 3.5 mm; 4.3 NP presented higher fracture resistance; the mechanical aging leads to screw loosening; the accelerated mechanical fatigue has influence in smaller diameters and the methodology in CT is valid for bi and three-dimensional analyzes
29

Eficácia de remoção da medicação intracanal de hidróxido de cálcio com o uso do ultrassom associado ou não ao instrumento adicional, avaliada através da microtomografia computadorizada / Effectiveness of intracanal calcium hydroxide removal with the use of ultrasound with or without an additional instrument, evaluated by computed microtomography

Silva, Luciana Jorge Moraes 02 September 2013 (has links)
Objetivos: avaliar a eficácia do uso da irrigação ultrassônica passiva (IUP), do instrumento adicional e da associação de ambos na remoção da medicação intracanal de hidróxido de cálcio através da microtomografia computadorizada (micro-CT). Material e métodos: foram selecionados 32 dentes humanos unirradiculares, preparados pela técnica de instrumentação rotatória com o sistema Protaper® universal até a lima final Finishing File 4 (F4). As amostras foram preenchidas com medicação intracanal de Ca(OH)2 associada ao propilenoglicol 400. Após 30 dias, os dentes foram divididos em quatro grupos, de acordo com a técnica de remoção da medicação. Nos grupos em que foi utilizada a IUP, esta foi realizada através da irrigação-aspiração com 5 mL de NaOCl 1%, 3 mL de EDTA 17% com agitação ultrassônica por um minuto a 2 mm do CRT e 5 mL de NaOCl 1%. O instrumento adicional utilizado foi a lima F5. No grupo controle, a remoção da medicação foi feita apenas com o instrumento final (F4) e com o uso do EDTA 17%, mantido por um minuto no interior do canal, sem ativação ultrassônica. As amostras foram avaliadas por meio da micro-CT, em três momentos distintos do procedimento endodôntico: 1) após preparo químico-cirúrgico do canal, 2) 30 dias após aplicação da medicação intracanal de Ca(OH)2 e 3) após remoção da medicação intracanal. As imagens microtomográficas foram avaliadas utilizando o software CTan (SkyScan). O canal foi dividido em terços apical, médio e cervical. Os conjuntos de dados foram analisados usando a escala de cinza do software CTan para quantificar o volume (em mm3) do canal após o preparo, o volume da medicação após 30 dias, o volume de resíduos de medicação e o volume do canal após remoção da medicação. A porcentagem de resíduos também foi calculada em relação ao volume do canal e ao volume de medicação após 30 dias. Finalmente, o aumento de volume do canal após a remoção também foi avaliada. Os dados foram analisados através de ANOVA de três fatores/teste de Tukey ou Kruskal-Wallis/Student-Newman-Keuls, com nível global de significância de 5%. Resultados: Independentemente da região do canal, o uso do ultrassom resultou em um menor volume de resíduos de MIC, em termos absolutos e em relação ao volume do canal. Em relação ao volume de medicação após 30 dias, o uso do ultrassom foi marginalmente significante. O uso do instrumento adicional não apresentou influência significante sobre a eficácia da remoção da MIC. A porcentagem de resíduos foi maior na região apical, quando o ultrassom não foi utilizado. Em números absolutos, a região cervical apresentou maior volume de resíduos. Em relação ao grupo controle, o uso do ultrassom resultou em um volume final maior do canal cirúrgico no terço cervical. Em termos percentuais, todas as técnicas resultaram em aumentos estatisticamente semelhantes do volume do canal cirúrgico para os terços cervical e médio. No terço apical, o grupo controle apresentou aumento percentual estatisticamente inferior aos demais. Conclusões: houve diferenças estatisticamente significantes na eficácia de remoção da MIC entre as técnicas testadas, sendo que o uso do ultrassom resultou em um menor volume de resíduos de MIC, em todos os grupos para um dado terço. / Objectives: To evaluate the efficacy of passive ultrasonic activation (PUI), an additional instrument and the combination of both for removal of intracanal calcium hydroxide using computerized microtomography (micro-CT). Methods: 32 singlerooted human teeth were prepared using the universal Protaper® rotary instrumentation system, with Finishing File 4 (F4) as the final file. The samples were filled with intracanal Ca(OH)2 plus propyleneglycol 400. After 30 days, the samples were divided into four groups according to the medication removal technique. In the groups where PUI was used, it was done by suction-irrigation with 5 mL of 1% NaOCl, 3 ml 17% EDTA with ultrasonic agitation for one minute at 2 mm from the working length and 5 ml of 1% NaOCl. The additional instrument used was the F5 file. In the control group, removal of the medication was performed only with the final instrument (F4) and using 17% EDTA, kept for one minute in the canal without ultrasonic activation. The samples were evaluated by micro-CT, at three different stages of the endodontic procedure: 1) after chemical-surgical preparation of canal 2) 30 days after application of the Ca(OH)2 medication 3) after removal of the medication. Microtomography images were evaluated using the CTan (SkyScan) Software. The root was divided in apical, middle and cervical. Each data set was analyzed using the CTan software gray scale to determine the volume (mm3) of the canal after the preparation, the volume occupied by the medication after 30 days, the medication residue volume and the volume of the canal after medication removal. The residue percentage was also calculated in relation to the volume of the canal and the volume of medication found after 30 days. Finally, the volume increase of the canal after medication removal was also assessed. Data were analyzed using threefactor ANOVA/Tukey test or Kruskal-Wallis/Student-Newman-Keuls with overall significance level of 5% Results: Regardless of the region, the use of ultrasound resulted in a smaller volume of residue in absolute terms and in relation to the volume of the canal. In relation to the volume of medication after 30 days, the use of ultrasound was only marginally significant. The use of an additional instrument showed no statistically significant influence on the effectiveness of MIC removal. The percentage of residue was higher in the apical region, when the ultrasound was not used. In absolute numbers, the cervical region showed the highest volume of residue. In relation to the control group, the use of ultrasound resulted in a higher final volume in the cervical third. All techniques resulted in statistically similar increases in the volume of the surgical canal for the cervical and middle thirds. In the apical third, the control group showed a statistically lower increase in volume than the others thirds. Conclusions: Statistically significant differences were found among the tested techniques, the use of ultrasound resulted in a smaller volume of residue in all groups for a particular third.
30

Avaliação por microtomografia de raio-X do reparo ósseo em osteotomia completa de tíbia de ratos após tratamento com ultrassom de baixa intensidade e laser de baixa potência / Assessment of bone repair by x-ray microtomography in complete Tiba rats osteotomy after low-intensity pulsed ultrasound and low-level laser therapy

Paolillo, Alessandra Rossi 12 December 2013 (has links)
As fraturas são consideradas um dos maiores problemas de saúde pública pelo custo e morbidade a elas associados. O objetivo deste estudo foi investigar os efeitos do ultrassom de baixa intensidade (LIPUS) e do laser de baixa potência (LLLT) sobre o reparo ósseo de tíbia de ratos (Wistar) utilizando a microtomografia por raio-x (&#956CT) e a análise histomorfométrica. Uma osteotomia total no terço médio foi fixada com fio de Kirschner (0,89 mm) e utilizado um espaçador polimérico de 2 mm de espessura e 1 mm de diâmetro entre os fragmentos proximal e distal para induzir retardo de consolidação da fratura. Foram utilizados 24 animais separados aleatoriamente em 4 grupos experimentais: Grupo Controle: sem tratamento do retardo da consolidação (n = 5); Grupo Laser: tratamento da fratura com laser (n = 6); Grupo LIPUS: tratamento da fratura com LIPUS (n = 7) e; Grupo LIPUS + Laser: tratamento da fratura com LIPUS e Laser (n = 7). Os tratamentos com LIPUS e/ou Laser foram iniciados após 5 semanas da cirurgia e realizados durante 5 dias consecutivos de tratamento, seguidos por 2 dias sem serem tratados até totalizarem 12 sessões terapêuticas. Os parâmetros de irradiação laser foram: 808 nm; 100 mW; 2500 mW/cm² , 125 J/cm² durante 50 segundos. Os parâmetros do LIPUS foram: 1,5 MHz, ciclo de trabalho 1:4, intensidade de 30 mW/cm², 20 minutos por sessão. Quando as duas técnicas foram associadas, o laser foi aplicado perpendicularmente ao LIPUS no décimo minuto de aplicação do LIPUS. Radiografias da tíbia foram feitas para acompanhar a evolução da fratura após a cirurgia, antes dos tratamentos e antes da eutanásia. Após a eutanásia foram realizadas avaliações microtomográficas por raio-x e histomorfométricas para análise do reparo ósseo. Na análise microtomográfica do reparo ósseo o tecido neoformado de reparo (calo ósseo) e o tecido normal não foram isolados. Na análise estatística foi utilizada a ANOVA one-way com posthoc de Tukey. Não foi constatada diferença significativa para maioria das variáveis, exceto para o fator padrão trabecular (Tb.Pf) no grupo LIPUS+Laser comparado aos grupos LIPUS (p = 0.02), Laser (p = 0.02) e Controle (p = 0.01), para a conectividade (Conn) no grupo Laser comparada ao grupo Controle (p = 0.04) e para a densidade de conectividade (D.Conn) no grupo LIPUS+Laser comparado ao grupo Controle (p = 0.04). As imagens histológicas mostram maior quantidade de tecido esponjoso no grupo LIPUS+Laser. Parâmetros morfométricos e histomorfométricos não revelaram um avanço do reparo ósseo na comparação entre os grupos com tratamento em relação ao grupo controle provavelmente devido a não reabsorção do espaçador polimérico pelo organismo dos animais. A &#956CT é uma técnica de grande potencial que permite análises qualitativas e quantitativas e reconstruçoes 2D e 3D. / Bone fractures are important public health problems due to the morbidity and high cost related to them. The aim of this study was to evaluate the effects of low pulsed intensity ultrasound (LIPUS) and infrared low level laser therapy (LLLT) in the bone repair of a transverse rat tibia osteotomy with assessement by x-ray microtomography (&#956CT) and histomorphometry. An easily implemented transverse osteotomy with a Kirchner wire and 2 mm width polymeric spacer beads established a delayed union in the fracture. Twenty four rats were divided into four experimental groups: Control Group - untreated; Laser Group - treated with infrared LLLT; LIPUS Group treated with low intensity pulsed ultrasound; LIPUS+Laser Group - treated with low intensity pulsed ultrasound and infrared LLLT. The treatments with infrared LLLT (808 nm, 100 mW, 2500 mW/cm², 125 J/cm², 50 seconds) and LIPUS (1,5 MHz, 1:4 duty cicle, 30 mW/cm², 20 minutes) started 5 weeks after the surgery following a sequence of 5 days on and 2 days off until 12 sessions were reached. When LLLT and LIPUS therapies were used simultaneously there was a 90º angle between the laser and the ultrasound beams. The surgical technique and the bone repair were assessed by x-ray radiography. One-way analysis of variance (one-way ANOVA) and Tukey post-hoc were used for statistical analysis. The normal bone and the callus were kept together in the &#956CT analysis. There was no significant difference between treatments results except for the parameters trabecular pattern factor - Tb.Pf [US+Laser group x LIPUS group (p = 0.02); US+Laser group x Laser group (p = 0.02) and US+Laser group x Control group (p = 0.01)], connectivity - Conn [Laser group x Control group (p = 0.04)] and connectivity density D.Conn [US+Laser group x Control group (p = 0.04)]. The histology showed greater amount of spongeous bone in the LIPUS+Laser group. The morphometric and histomorphometric assessments didn´t show a faster bone repair when treated groups were compared against the control one. The non absorption of the polymeric spacer bead is probably the reason of these findings. The &#956CT is a powerful technique that allows 2D and 3D quantitative analysis and reconstructions.

Page generated in 0.0553 seconds