• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 14
  • 1
  • 1
  • 1
  • Tagged with
  • 17
  • 17
  • 11
  • 11
  • 11
  • 9
  • 7
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Sistema de pintura anticorrosiva monocomponente aplicado diretamente sobre o metal substituto ao sistema tradicional de três componentes - Desenvolvimento e avaliação de formulações de tinta base água / Anticorrosive one component paint system applied directly on metal in substitution to three components traditional system - Development and evaluation of water based paints

Álann de Oliveira Piagentini Bragatto 07 June 2018 (has links)
O trabalho desenvolvido tem como objetivo avaliar um sistema de pintura anticorrosiva aplicado diretamente sobre o metal, sistema DTM, em relação a um sistema tradicional, composto por Primer, Intermediário e Top Coating, ambos base solventes e destinados para aplicações arquitetônicas, e propor o desenvolvimento e avaliação de formulações base água substitutas à base solvente, procurando-se determinar a influência de determinados componentes presentes nas formulações, tais como o dióxido de titânio, fosfato de zinco, caulim, inibidor de corrosão orgânico e agente reticulante nas propriedades anticorrosivas da tinta. São realizadas avaliações das propriedades anticorrosivas das tintas por meio de medidas de potencial de circuito aberto (EOCP), espectroscopia de impedância eletroquímica (EIS) e ensaio acelerado de corrosão em câmara de névoa salina. Além das propriedades anticorrosivas, as tintas DTM base água formuladas são avaliadas comparativamente à tinta DTM base solvente em outras propriedades, particularmente em relação à resistência à água, por meio de medidas de absorção de água, permeabilidade ao vapor dágua e determinação do ângulo de contato, e em relação às propriedades estéticas, tais como o poder de cobertura de tinta úmida e seca. Os resultados demonstram que o sistema DTM basesolvente apresenta desempenho anticorrosivo equivalente ao sistema tradicional. Dentre as formulações base água avaliadas, verifica-se que o uso do fosfato de zinco como pigmento anticorrosivo e de um agente reticulante na formulação é fundamental para se obter um desempenho anticorrosivo satisfatório. Também é demonstrado que a resistência à água dos filmes é um fator fundamental a ser melhorado nas tintas base água para que se possa obter resultados satisfatórios em relação à resistência à corrosão para longos períodos de exposição como o obtido para o sistema base solvente. / The developed work aims to evaluate an anticorrosive paint system applied directly on metal, DTM system, in relation to a traditional three components paint system, composed by Primer, Intermediary Coating and Top Coating - both systems solvent based and intended to architectural applications. The work also aims to develop and evaluate water based DTM paint formulations in substitution to solvent based paint system, determining the influence of some components present in the formulations, such as titanium dioxide, zinc phosphate, kaolin, organic corrosion inhibitor and a crosslinker agent, in the anticorrosive properties of the paint. The anticorrosive properties of the paint are evaluated by open circuit potential measures (EOCP), electrochemical impedance spectroscopy (EIS) and accelerated corrosion test in the salt-spray chamber. Besides the anticorrosive paints properties, water based DTM formulated paints are compared to solvent borne DTM paint in other properties, particularly in relation to water resistance, by measures of water absorption, water vapor permeability and contact angle, and also in relation to aesthetic properties, such as dry and wet hiding power. The results demonstrated that anticorrosive performance of solvent borne DTM paint system is similar to the solvent borne traditional paint system. In relation to formulatedwater based DTM paints, it was observed that the use of zinc phosphate as an anticorrosive pigment and a crosslinker agent in the formulation is essential to obtain a satisfactory anticorrosive performance. It is also demonstrated that the paint films water resistance is a fundamental property to be improved in water based paints in order to obtain satisfactory results in relation to corrosion resistance for long periods of exposure, just as observed for solvent borne system.
12

Resistência à tração de retentores intra-radiculares fundidos sumetidos ao acabamento após cimentação com fosfato de zinco

Iglésias, Michele Andréa Lopes 11 July 2007 (has links)
The refinement of the coronary portion of the intraradicular post cemented constitutes in routine in the clinic. However, the effects of the action of the diamond burn in high rotation on the cement agent are little argued. This study is tested the hypothesis of that the refinement with high rotation an the passed time between the cementation and the accomplishment of the refinement have negative effect in the tensile strength of the intraradicular post cemented in bovine roots. Forty eight bovine roots have been parted with 15mm of length, endodontically treated, confectioned in Cu-Al league, cemented with cement zinc phosphate and divided in 4 experimental groups (n=12). Group A: Without refinement; Group B, C e D submitted the refinement 15, 60 minutes and 24 hours respectively, after the cementation. The assay was carried through in universal machine (EMIC) with speed of 0,5mm/min for all the groups 24 hours after the cementation. The data of tensile strength had been analyzed by the analysis of the variance and test of Bartlet (α=1%). Verified that it did not have significant difference between the groups. Inside of the limitation of this study it can be concluded that the refinement with high rotation and the factor passed time between the cementation and assay did not produce effect of the resistance of the intraradicular posts. / O acabamento da porção coronária do retentor intra-radicular fundido após cimentação constitui-se rotina na clínica odontológica. Entretanto, os efeitos da ação da ponta diamantada em alta rotação sobre o agente cimentante são pouco avaliados. Este estudo testou a hipótese de que o tempo decorrido entre a cimentação e a realização do acabamento com alta rotação tenha efeito negativo na resistência à tração dos retentores intra-radiculares fundidos. Quarenta e oito raízes bovinas foram seccionadas com 15 mm de comprimento, tratadas endodonticamente e divididas aleatoriamente em quatro grupos (n=12): n=A: não submetidos ao acabamento; n=B, C e D submetidos ao acabamento com os tempos de 15, 60 minutos e 24 horas respectivamente, após a cimentação. Os condutos foram moldados pela técnica direta para a obtenção de retentores com 11 mm de comprimento intra-radicular, fundidos em cobre-alumínio, jateados com óxido de alumínio e cimentados com fosfato de zinco. O ensaio de tração foi realizado em máquina universal (EMIC) com velocidade de 0,5mm/min para todos os grupos 24 horas após a cimentação. Os resultados foram submetidos à análise de variância e teste de Bartlet (α=1%). Não houve diferenças estatisticamente significantes na resistência à tração nos grupos controle e os grupos com acabamento após a cimentação, independente do período de espera. Dentro das limitações deste estudo concluiu-se que o acabamento com alta rotação e o tempo decorrido entre a cimentação e o ensaio não produziu efeito sobre a resistência dos retentores intra-radiculares fundidos em cobre-alumínio. / Mestre em Odontologia
13

Avaliação in vitro da microdureza dentinária radícular em dentes bovinos após aplicação de diferentes tratamentos com hipoclorito de sódio associado ou não ao cimento de fosfato de zinco / In vitro evaluation of the root-dentin microhardness of bovine teeth after treatment with sodium hypochlorite associated or not with zinc phosphate

Paola Bechtold 01 September 2006 (has links)
O objetivo deste estudo foi avaliar o comportamento da dentina radicular bovina frente a duas condições experimentais: a aplicação de soluções de hipoclorito de sódio nas concentrações de 0,5% e 2,5% sobre a superfície da luz radicular e a aplicação das mesmas substâncias seguida do cimento de fosfato de zinco, comparando a microdureza dentinária em duas distâncias em relação à luz do canal, nos terços radiculares. Foram utilizadas 30 raízes de incisivos superiores bovinos. Cada raiz foi seccionada em três posições: terço cervical (C), médio (M) e apical (A). Estas foram submetidas ao teste de microdureza Knoop ( KHN a 100g/15 seg) em duas distâncias, 100 ?m e 300 ?m em relação à luz radicular (momento I). Em seguida receberam um tipo de tratamento formando seis Grupos experimentais: 1A - hipoclorito de sódio a 0,5% , 1B – hipoclorito de sódio a 2,5%,1C – solução fisiológico, 2A – hipoclorito de sódio a 0,5% + fosfato de zinco, 2B – hipoclorito de sódio a 2,5% + fosfato de zinco e 2C – solução fisiológico + fosfato de zinco. Nos Grupos 1A, 1B e 1C após a aplicação das substâncias, as superfícies foram vedadas e decorrida uma semana um novo teste de microdureza Knoop (momento II) foi realizado. Os corpos-de-prova dos Grupos 2A, 2B e 2C receberam as soluções testadas por 60 segundos e em seguida a aplicação do cimento de fosfato de zinco, quando foram vedadas e após uma semana foram submetidos a novo teste de microdureza (momento II). Os corpos-de-prova do Grupo 2A, 2B e 2C foram observados ao MEV na região da interface cimento/dentina. Os resultados foram submetidos à análise de variância com medidas repetidas, pois cada dente foi avaliado em seis combinações entre posição (C, M e A) e distância (100 ?m e 300 ?m) e não apresentaram diferença estatisticamente significante (?=0,05) entre as combinações de posição, distância. Somente houve diferença significante (p=0,0000) quando os valores de KHN foram comparados em relação às distâncias 100 ?m e 300 ?m, sendo que a 300 ?m os valores foram maiores. Assim, os valores referentes aos 3 terços foram agrupados formando uma única média para cada distância. Pelo Teste-t pareado, as médias foram comparadas nos momentos I e II em cada distância e observou-se diferença estatisticamente significante (?=0,05) entre os grupos 1C e 2A (p=0,012 à 100 ?m, p=0,006 à 300 ?m; p=0,024 à 100 ?m e p=0,047 à 300 ?m, respectivamente). Para comparação do comportamento da dentina antes e depois dos tratamentos após uma semana, todas as médias do momento I foram juntadas num único grupo (grupo momento I). A análise de variância o grupo 1C apresentou diferença estatisticamente significante em relação ao grupo formado pelas médias de microdureza no momento I a 100 ?m e 300 ?m; 1B e 2B a 100 ?m e 1B, 2B e 2C a 300 ?m. Com isso, podemos concluir que a dentina radicular sem qualquer tratamento anti-séptico após uma semana apresenta seus valores de microdureza diminuídos de maneira significante em relação às medidas iniciais (I) e aos demais grupos experimentais. / The aim of this study was to evaluate the behavior of the bovine root-dentin under two experimental conditions: the application over the lumen surface with sodium hypochlorite solutions in concentrations of 0,5% and 2,5%, and the application of the same solutions after zinc phosphate cement was applied. The dentin microhardness was compared at two distances from the lumen, in the radicular thirds. In this study, 30 roots of bovine upper incisor were used. Each root was sectioned in the thirds: cervical (C), medium (M) and apical (A), and submitted to the Knoop microhardness test (KHN at 100g/15s) at two distances: 100 ?m and 300 ?m from lumen (I). After that, the species received one type of treatment determining six experimental groups: 1A – sodium hypochlorite 0,5%, 1B - sodium hypochlorite 2,5%, 2C – physiologic solution, 2A - sodium hypochlorite 0,5% + zinc phosphate, 2B - sodium hypochlorite 2,5% + zinc phosphate e 2C - physiologic solution+ zinc phosphate. In the Groups 1A, 1B and 1C after these solutions were applied, surfaces were sealed and one week later a new measure of microhardness (KHN) was taken (II). The Groups 2A, 2B and 2C received the tested solutions for 60 seconds following application of zinc phosphate cement, them they were sealed and after seven days a new measure was taken (II). The samples of Group 2A, 2B and 2C were observed on MEV micrographs in the cement/dentin interface. Analysis of variance with repeated measures, as each tooth was evaluated in six combinations of positions (C, M, A) and distances (100 ?m and 300 ?m), showed that there were no statistical (?=0,05) differences between combinations of position and distance. There was only significant difference (P=0,000) when KHN values were compared in relation to distances (100 and 300?m), and at 300 ?m higher values was found. The values from the thirds were grouped resulting in sole mean for each distance. Pared test-t was run to compare values I and II, in each distance significant difference was found in Group 1C and 2A (P=0,012 at 100, P=0,006 at 300; P=0,024 at 100 e P=0,047 at 300, respectively). To compare dentin behavior pre and post treatments after a week, all averages of values I were joined in a single group (group moment I). Under the Analysis of variance group 1C showed a significant difference in relation to the group formed by averages of microhardness in value I at 100 ?m and 300 ?m; 1B and 2B at 100 ?m and 1B, 2B and 2C at 300 ?m. Therefore, it can be concluded that root dentin with no anti-septic treatment after one week significantly shows decreased values of microhardness in relation to the initial measures (I) and to the others experimental groups.
14

Caracterização e estampabilidade de um aço SAE 1080 fosfatizado. / Characterization and stampability of SAE 1080 phosphatized steel.

Daniel Augusto Ferro 04 February 2015 (has links)
Devido a crescente necessidade de elevação dos níveis de conformação em peças estampadas em geral, existe uma demanda cada vez maior em ligas e processos diversificados que atendam as variadas exigências do setor de produtos estampados e posteriormente tratados termicamente para aumento de dureza. Desse modo desenvolveu-se a liga C80U modificada, que é uma variante da liga C80U especificada na norma DIN EN ISO 4957 porém com adição de Cromo, entretanto a liga C80U modificada ainda é pouco estudada e pouca informação técnica se tem a seu respeito. Com a finalidade de melhor conhecimento técnico dessa liga, foram conduzidos estudos de caracterização em amostras laminadas a quente e após processo de esferoidização posteriormente sendo revestidas com fosfato de zinco. Foram realizados estudos de composição química, microestrutura, textura cristalográfica, propriedades mecânicas e estrutura do fosfato, além de levantamento da curva CLC através do método Nakazima e evolução da rugosidade 2D e 3D em amostras com e sem revestimento de fosfato, antes e após conformação. Através dos resultados parciais encontrados, foi possível definir o lado da curva CLC relacionado ao estiramento da chapa bem como comparar o deslocamento e a força do punção no teste Nakazima conformando-se amostras esferoidizadas sem revestimento e com revestimento de fosfato. / Due to the increasing demand for enhanced formability levels of stamped parts in general, there is also an increasing demand for various alloys and processes that comply with the various requirements associated with stamped products that are subsequently heat treated to increase their hardness. Along this line, a modified C80U alloy has been developed, which is a variant of the alloy C80U specified in the standard DIN EN ISO 4957 but with the addition of Chrome. However, this alloy is still poorly studied and little technical information is available about it. In order to increase the knowledge of this alloy, characterization studies were conducted on hot rolled, after spheroidization and subsequently coated with zinc phosphate samples. The studies performed included chemical composition, microstructure, crystallografic texture, mechanical properties and analysis of the phosphate structure, as well as Nakazima tests in order to obtain the forming limit diagram (FLD) curve and the 2D and 3D roughness evolution of spheroidized samples coated and uncoated before and after the stamping process. Through the partial results obtained, it was possible to define the side of FLD curve related to stretching of the sheet as well as comparing the displacement and force of the punch on Nakazima test, stamping spheroidized samples both uncoated and coated with zinc phosphate.
15

\"Estudo da evolução da reação de presa do cimento de fosfato de zinco através de luz laser, aplicando a técnica óptica de speckle dinâmico\" / Study of evolution of zinc phosphate cement´s setting reaction by laser, applying an optics technique of dynamic speckle

Dino Jeiset Kon 09 October 2006 (has links)
A cimentação de próteses e/ou de outros elementos protéticos constituem-se em uma preocupação permanente, já que uma das grandes aplicações do cimento de fosfato de zinco é como agente cimentante. No entanto, a reação de presa do cimento de fosfato de zinco, assim como o tempo de sua presa final, não estão ainda completamente esclarecidos. O presente estudo visa analisar, microestruturalmente, a evolução da reação de presa do cimento de fosfato de zinco. Mais especificamente, buscou-se mensurar, baseado no fenômeno conhecido como speckle dinâmico, o tempo de duração da reação de presa do cimento de fosfato de zinco, desde o momento do término da espatulação até a sua presa completa, em ambiente com temperatura e umidade relativa do ar controlada. A metodologia utilizada consiste na análise do speckle dinâmico obtido através da luz laser, em um ensaio não-destrutivo. A partir dos dados coletados pela técnica óptica de speckle, usando algoritmos computacionais, foi possível estabelecer os coeficientes de correlação temporal e momentos de intensidade. O tratamento estatístico permitiu relacionar e comparar com outros parâmetros tradicionais, químicos e mecânicos macroestruturais já existentes e estudados por outros autores. Pode-se concluir que os resultados alcançados pela nova técnica e pelos métodos convencionais são convergentes. / The prosthesis cementation and/or other prosthetic elements, consists in permanent concern, since one of the major applications of zinc phosphate cement is as lutting agent. This study aims at the microstructural analyze to the evolution of the zinc phosphate cement´s setting reaction. More specifically, searched to verify, based on the known phenomenon as dynamic speckle, how long takes the setting reaction of zinc phosphate cement, since the moment of the ending of the mix until your complete setting, in environment with air relative humidity and temperature controlled. The used methodology consist in the analysis of dynamic speckle gotten through the laser, in a non-destructive assay. From the data supplied by the laser speckle, it was possible to establish the temporal correlation coefficients and intensity moments. The statistical treatment, allowed to compare and relate with other traditional, chemical and mechanical macrostructural parameters, already existing and studied by other authors. It can be conclude that outcomes achieved by the new technique and with the conventional methods are convergent.
16

Avaliação da infiltração marginal e da resistência à tração de coroas metálicas após abertura oclusal para terapia endodôntica: estudo in vitro / Evaluation of cast crowns microleakage and retentive strength after occlusal Access for endodontic therapy: in vitro study

Rogério Issao Sonoki 20 September 2006 (has links)
Este estudo in vitro teve como objetivo determinar a infiltração marginal e resistência à remoção por tração de coroas totalmente metálicas, cimentadas com cimento de fosfato de zinco e que foram submetidas à abertura oclusal para tratamento endodôntico. Foram usados 20 dentes molares (Banco Permanente de Dentes Humanos da FOUSP). Os dentes foram fixados sobre uma base acrílica de secção circular e foram torneados configurando preparos para coroas totais com dimensões de altura e diâmetro padronizadas. Coroas metálicas em Ni Cr foram fundidas através da técnica de enceramento direto e cimentadas com cimento de fosfato de zinco com carga axial de 5 Kg por 10 minutos. Os corpos de prova foram divididos em: Grupos Controle GC1 e GC2, que utilizaram os mesmos corpos de prova, e Grupo Experimental (GE). Todos os corpos de prova foram mantidos em água destilada para que não se desidratassem. Os espécimes dos grupos GC1 e GC2 foram mantidos sem nenhuma intervenção e os do grupo GE foram perfurados com broca de carbide de tungstênio, simulando uma cirurgia de acesso endodôntico. As amostras dos grupos GC2 e GE foram submetidas à ciclagem térmica de 700 ciclos entre 5º e 55º C. Em seguida foram mantidos em uma solução de azul de metileno 0,5%, ph 7,2 por 4 horas a 37º C. Foram submetidos ao ensaio mecânico de tração das coroas em uma máquina universal de ensaios Kratos SV 100, regulada para trabalhar a uma velocidade de ensaio de 0,5 mm/minuto. Os resultados obtidos foram submetidos à análise estatística pelos testes t de Student e as infiltrações avaliadas pela correlação linear de Spearman. A análise inferencial dos resultados dos testes de tração demonstrou com um nível de significância p=0,108, entre os grupos GC1 e GC2, e p=0,502, entre os grupos GC2 e GE, não haver diferença estatisticamente significante. As médias dos valores obtidos nos testes de tração e os seus respectivos desvios padrão foram: GC1 13,96+/-4, 48, GC2 11,26+/-2,269 e GE 10,09+/-4,86 (valores em Kgf). A análise visual subjetiva da infiltração nos corpos de prova indicou que o grupo GE apresentou o maior grau de infiltração marginal com presença do corante atingindo o terço oclusal das paredes axiais (mediana dos scores 3). O grupo GC2 apresentou infiltração marginal no terço médio (mediana dos scores 2). O grupo GC1 apresentou infiltração marginal no terço cervical e médio (mediana dos scores 1). / This in vitro study had the objective to determine the marginal microleakage and the retentive strength of totally metallic crowns, cemented with zinc phosphate cement and subjected to occlusal access for endodontic treatment. 20 human molars (Banco Permanente de Dentes Humanos da FOUSP) have been used for the experiment. The teeth were fixed on a circular acrylic section base and were prepared with standardized dimensions. Metallic crowns in Ni Cr were cast with the direct waxing technique and cemented with zinc phosphate cement with vertical load of 5 kg for 10 minutes. The specimens were divided in groups: Group Control 1 (GP1), Group Control 2 (GP2) and Group Experimental (GE). All the specimens were kept on distillated water so that they wouldn’t dehydrate. The specimens of the groups GC1 and GC2 were kept without any intervention and the ones of the group GE were drilled with a tungstein carbide bur, simulating an endodontic access surgery. Next, the samples of groups GC2 and GE were subjected to a thermal cycling of 700 cycles between 5º and 55º C. To verify the existence of micro infiltration, it was used the methylene blue dye test, 0,5%, ph 7,2 for 4 hours at 37ºC. The specimens were subjected to the load of tension in a universal tensile testing machine Kratos SV 100 at speed 0,5 mm/min. Statistical analyses with t tests showed no significant difference between crown retention before and after endodontic access preparation (p=0,108). The mean displacement forces were: GC1 13,96+/-4,48, GC2 11,26+/-2,269 e GE 10,09+/-4,86 (value in Kgf). With the Spearman’s evaluation test the microleakage was measured. The results showed a greater median of score in GE (score 3). The GC2 and GC1 showed median scores 2 and 1 in order.
17

Evaluation of fracture resistance of three post and core systems in endodontically treated teeth under loading to failure; and marginal gap measurement before and after cyclic loading

Saad, Amir N., 1979- January 2009 (has links)
Indiana University-Purdue University Indianapolis (IUPUI) / The purpose of this study was to evaluate the fracture resistance of three post and core systems in endodontically treated teeth by loading to failure, and to measure marginal gaps before and after cyclic loading. Sixty extracted canines were assigned to three groups. The groups tested were: 1) Single cast post and core (Group CP). 2) Prefabricated metal post and composite resin core (Group MR). 3) Glass fiber post and composite resin core (Group FR). All teeth were obturated and prepared to receive a post and core with a coping. Thirty teeth (10 from each group) were loaded to failure, and the other 30 teeth were fatigue-loaded. The marginal gaps on the facial and lingual surface of the fatigue-loaded group were measured before and after cyclic loading. There were two hypotheses for this study. The first was that the FR group would have less marginal gap opening on the lingual surface than the other groups. The second was that the CP group would have a higher load at failure than the other groups. Group CP was found to have a significantly smaller pre-loading marginal gap than group FR (p = 0.0265) and group MR (p = 0.0273), while groups FR and MR did not have a significantly different pre-loading marginal gaps (p = 0.86). Group FR had significantly less change in marginal gap than group MR (p = 0.0013). Groups CP and MR did not have significantly different changes in marginal gap (p = 0.09). Groups CP and FR did not have significantly different changes in marginal gap (p = 0.11). The three post types did not have significantly different maximum loads to failure (p= 0.49), moments of inertia at cervical area (p = 0.75), or moments of inertia at fracture site (p=0.12). There was no significant difference between groups CP, FR, and MR in the load-to-failure test. Group CP demonstrated the highest load-to-failure values; however, the highest load-to-failure mean was for group MR. All fractures observed in this study were catastrophic. Group FR demonstrated better stress distribution and caused no early fractures in the fatigue-loading group. All groups demonstrated significant marginal gap changes on the lingual surface after fatigue loading; however, group FR demonstrated <45 μm marginal gap opening. In group FR, the reduced marginal gap opening was attributed to the use of Panavia 21 with the proper surface treatments to bond to the tooth structure, the resin composite, and the metal coping.

Page generated in 0.0623 seconds