• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • 1
  • Tagged with
  • 5
  • 5
  • 4
  • 4
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Mesure de distance absolue utilisant l'interférométrie à balayage de longueur d'onde étalonnée par un peigne de fréquences / Absolute distance measurement using frequency sweeping interferometry calibrated by frequency comb

Yu, Wenhui 10 April 2019 (has links)
Dans cette thèse, nous avons mis en oeuvre un système de mesure de distance absolue (Absolute Distance Measurement, ADM) de haute précision utilisant l'interférométrie à balayage de fréquence (Frequency Sweeping Interferometry, FSI). La technique FSI exige que la plage de réglage de fréquence du laser balayé soit mesurée avec une précision élevée, ce qui est difficile en raison de l'absence d'un moyen simple de mesurer la haute fréquence d'un laser en temps réel. Dans cette thèse, un peigne de fréquence a été utilisé comme règle de fréquence lumière pour mesurer la plage de réglage de la fréquence du laser à balayage. Un peigne de fréquence formé par un laser femtoseconde est constitué de millions de lignes de peigne régulièrement espacées, ce qui permet de le considérer comme une règle de fréquence de la lumière. La calibration de fréquence a été réalisée en filtrant le signal hétérodyne entre le laser à balayage et les lignes de peigne en utilisant un filtre passe-bande étroit. Cette approche nous permet de détecter le signal d'étalonnage lorsque la fréquence du laser à balayage est proche d'une ligne en peigne. Etant donné que l’intervalle de fréquence entre les lignes de peigne peut être mesuré avec précision ou activement verrouillé en phase par rapport à un oscillateur radiofréquence (RF) stable, la plage d ’ accord du laser à balayage peut être mesurée avec une grande précision. En particulier, chacun des deux pics d’étalonnage peut être utilisé dans le calcul de la distance, ce que nous appelons des «sous-mesures» en un seul balayage. Combinée au grand nombre de lignes de peigne, la moyenne des sous-mesures améliore considérablement la précision des mesures sans balayage multiple. Dans la thèse, la condition de détection et les caractéristiques du signal hétérodyne entre le laser à balayage et la ligne de peigne sont présentées. Une conception de filtre pour filtrer le signal hétérodyne est réalisée. Un travail de modélisation concernant l'effet du bruit de phase des lasers sur la distorsion d'enveloppe du pic d'étalonnage a été présenté. Des travaux expérimentaux basés sur les concepts de mesure ont été réalisés. Il montre que l'utilisation du schéma de mesure proposé peut considérablement améliorer la précision de la mesure de distance. Dans l’une des mesures, une précision de 30 nm pour une distance d’environ 0,8 m, correspondant à une incertitude relative de 37 ppm (part-perbillion) a été obtenue. Le résultat a été obtenu sur la base d'une méthode de traitement du signal de comptage de franges. La grande précision a été obtenue grâce au grand nombre de sous-mesures et à la stabilité des lignes de peigne régulièrement espacées. Nous avons constaté que la mesure de vibration de la cible peut également être effectuée en prenant avantage des lignes de peigne denses. Une sensibilité élevée, limitée à 1,7 nm efficace en bruit, de la mesure des vibrations a été atteinte. Ce résultat nous permet de surveiller la vibration de la cible, ce qui est un problème important de la technique FSI. / In this thesis, we implemented a high-precision absolute distance measurement (ADM) system using frequency sweeping interferometry (FSI). The FSI technique requires the frequency tuning range of the swept laser to be measured with high accuracy and precision, which is challenging due to the lack of an easy way to measure the high frequency of a laser in real time. In this thesis, a frequency comb has been used as the light frequency ruler for measuring the frequency tuning range of the sweeping laser. A frequency comb formed by a femtosecond laser consists millions of evenly spaced comb lines so that can be regarded as a light frequency ruler. The frequency calibration was realized by filtering the heterodyne signal between the sweeping laser and the comb lines using a narrow bandpass filter. This approach allows us to detect the calibration signal when the frequency of the sweeping laser is in the vicinity of a comb line. As the frequency interval between the comb lines space can be precisely measured or actively phase-locked against a stable radio-frequency (RF) oscillator, the tuning range of the sweeping laser could be measured with high accuracy. Especially, each two calibration peaks can be used in the calculation of distance, which we call sub-measurements in a single sweeping. Combined with the large number of the comb lines, averaging of the sub-measurements improves greatly the measurement precision without multiple sweeping. In the thesis, the condition of detecting and the characteristics of the heterodyne signal between the sweeping laser and the comb line are presented. A filter design for filtering the heterodyne signal is performed. A modeling work concerning the effect of the phase noise of lasers on the envelope distortion of the calibration peak has been presented. Experimental works based on the measurement concepts have been carried out. It shows that using the proposed measurement scheme can greatly improve the distance measurement precision. In one of the measurements, a precision of 30 nm for a distance around 0.8 m, corresponding to 37 ppb (part-per-billion) relative uncertainty has been achieved. The result was obtained based on a fringe counting signal processing method. The high precision was obtained thanks to the large number of sub-measurements and the stability of the evenly spaced comb lines. We have found that vibration measurement of the target can be also performed taking the advantage of the dense comb lines. A high sensitivity, limited by 1.7 nm noise RMS, of vibration measurement has been achieved. This result allows us to monitor the vibration of the target, which is an important issue of FSI technique.
2

Hyperspectral interferometry for single-shot profilometry and depth-resolved displacement field measurement

Widjanarko, Taufiq January 2011 (has links)
A new approach to the absolute measurement of two-dimensional optical path differences is presented in this thesis. The method, which incorporates a white light interferometer and a hyperspectral imaging system, is referred to as Hyperspectral Interferometry. A prototype of the Hyperspectral Interferometry (HSI) system has been designed, constructed and tested for two types of measurement: for surface profilometry and for depth-resolved displacement measurement, both of which have been implemented so as to achieve single shot data acquisition. The prototype has been shown to be capable of performing a single-shot 3-D shape measurement of an optically-flat step-height sample, with less than 5% difference from the result obtained by a standard optical (microscope) based method. The HSI prototype has been demonstrated to be able to perform single-shot measurement with an unambiguous 352 (m depth range and a rms measurement error of around 80 nm. The prototype has also been tested to perform measurements on optically rough surfaces. The rms error of these measurements was found to increase to around 4× that of the smooth surface. For the depth-resolved displacement field measurements, an experimental setup was designed and constructed in which a weakly-scattering sample underwent simple compression with a PZT actuator. Depth-resolved displacement fields were reconstructed from pairs of hyperspectral interferograms. However, the experimental results did not show the expected result of linear phase variation with depth. Analysis of several possible causes has been carried out with the most plausible reasons being excessive scattering particle density inside the sample and the possibility of insignificant deformation of the sample due to insufficient physical contact between the transducer and the sample.
3

Relative distance and the use of `this’ and `that’ and possible deictic response

Lewinski, Sandra L. January 2014 (has links)
No description available.
4

Konzeption und Umsetzung neuer Technologien zur biaxialen Winkelmessung und elektrooptischen Pseudostreckenmessung

Fuhrland, Matthias 31 January 2008 (has links) (PDF)
Ein Ziel der Arbeit war die Entwicklung eines Verfahrens zur 3D-Positionierung auf Basis elektrooptischer Pseudostreckenmessung. Ein zweites Ziel war die Entwicklung eines Reflexgoniometers zur zweiachsigen Winkelmessung. Im Rahmen der Arbeit wurden die Grundlagen zur instrumentellen Umsetzung beider Verfahren erarbeitet, die Genauigkeitspotentiale ermittelt und mögliche Anwendungen für die einzelnen Schlüsseltechnologien und deren Kombination abgeleitet. In einer Prototyp-Entwicklung wurden Vorschläge für die wesentlichen Funktionselemente des räumlichen Weg- bzw. Winkelmesssystems gemacht. Hierzu gehören das kardanisch aufgehängte Etalon, die temperaturstabilisierte Laseroptik und die temperaturkalibrierte CCD der Winkelmesseinheit (Reflexgoniometer), die Systeme zur Erzeugung und Detektion ultrakurzer Laserpulse, eine elastische Optik, Möglichkeiten zur Formung des transversalen Strahlprofils, das TCSPC-System und die zur Auswertung und Kalibrierung notwendigen Algorithmen, wie z.B. die Autokollimation eines Lasers. ("Veröffentlicht von der Deutschen Geodätischen Kommission Reihe C (Dissertationen) unter der Nummer C 614 (München 2008; ISBN 3 7696 5053 0; 2; 144 S.") / One goal of the thesis was the development of a method for three-dimensional positioning based on electro-optical measurement of pseudo ranges. Another goal was the development of a reflex goniometer for biaxial angle measurement. Within the scope of this thesis the basics for the instrumental realisation of both methods were developed, the accuracy potentials were determined and possible applications for the separate key technologies and their combination were deduced. In a prototype development proposals were made for the main functional elements of the spatial distance and angle measurement systems. These include the gimbal mounted etalon, the temperature stabilised laser optics and the temperature calibrated CCD of the angle measurement device (reflex goniometer), the systems for creation and detection of ultrashort laser pulses, an elastic optical device, possibilities of transversal beam shaping, the TCSPC system and the algorithms which are necessary for analysis and calibration, e.g. the autocollimation of a laser.
5

Konzeption und Umsetzung neuer Technologien zur biaxialen Winkelmessung und elektrooptischen Pseudostreckenmessung

Fuhrland, Matthias 30 November 2007 (has links)
Ein Ziel der Arbeit war die Entwicklung eines Verfahrens zur 3D-Positionierung auf Basis elektrooptischer Pseudostreckenmessung. Ein zweites Ziel war die Entwicklung eines Reflexgoniometers zur zweiachsigen Winkelmessung. Im Rahmen der Arbeit wurden die Grundlagen zur instrumentellen Umsetzung beider Verfahren erarbeitet, die Genauigkeitspotentiale ermittelt und mögliche Anwendungen für die einzelnen Schlüsseltechnologien und deren Kombination abgeleitet. In einer Prototyp-Entwicklung wurden Vorschläge für die wesentlichen Funktionselemente des räumlichen Weg- bzw. Winkelmesssystems gemacht. Hierzu gehören das kardanisch aufgehängte Etalon, die temperaturstabilisierte Laseroptik und die temperaturkalibrierte CCD der Winkelmesseinheit (Reflexgoniometer), die Systeme zur Erzeugung und Detektion ultrakurzer Laserpulse, eine elastische Optik, Möglichkeiten zur Formung des transversalen Strahlprofils, das TCSPC-System und die zur Auswertung und Kalibrierung notwendigen Algorithmen, wie z.B. die Autokollimation eines Lasers. ("Veröffentlicht von der Deutschen Geodätischen Kommission Reihe C (Dissertationen) unter der Nummer C 614 (München 2008; ISBN 3 7696 5053 0; 2; 144 S.") / One goal of the thesis was the development of a method for three-dimensional positioning based on electro-optical measurement of pseudo ranges. Another goal was the development of a reflex goniometer for biaxial angle measurement. Within the scope of this thesis the basics for the instrumental realisation of both methods were developed, the accuracy potentials were determined and possible applications for the separate key technologies and their combination were deduced. In a prototype development proposals were made for the main functional elements of the spatial distance and angle measurement systems. These include the gimbal mounted etalon, the temperature stabilised laser optics and the temperature calibrated CCD of the angle measurement device (reflex goniometer), the systems for creation and detection of ultrashort laser pulses, an elastic optical device, possibilities of transversal beam shaping, the TCSPC system and the algorithms which are necessary for analysis and calibration, e.g. the autocollimation of a laser.

Page generated in 0.0892 seconds