11

[en] IMPLEMENTATION OF NEW VOLTAGES OF REFERENCE IN OPERATION POINTS WITH ADEQUACY PROBLEMS OF VOLTAGE CONTROL ACTIONS BY GENERATOR / [pt] IMPLEMENTAÇÃO DE NOVAS TENSÕES DE REFERÊNCIA EM PONTOS DE OPERAÇÃO COM PROBLEMA DE ADEQUAÇÃO DAS AÇÕES DE CONTROLE DE TENSÃO POR GERADORES

30 January 2013 (has links)
[pt] Casos reais de blecaute, caracterizados por afundamento de tensão, indicam que os procedimentos normais para o controle automático de tensão podem agravar o nível de tensão. Isto ocorre porque, em situações especiais, as ações de controle têm o efeito oposto ao esperado da sua lógica de projeto. Essas situações especiais podem ser identificadas através de ferramenta computacional que, baseada no sistema linearizado das equações de fluxo de carga e de todas as outras equações de controle consideradas pertinentes, determina uma matriz de sensibilidade dos controles através da qual se pode estabelecer a relação existente entre as tensões controladas e as grandezas controladoras dos dispositivos de controle de tensão. O controle de tensão em geradores síncronos é realizado por reguladores automáticos de tensão (RAT) que, na prática, não têm lógica de controle para diferenciar relação direta e inversa entre a tensão controlada e a tensão de excitação do gerador. Assim, se a relação é inversa, o resultado da ação do RAT é inadequado (oposto ao desejado) e pode levar o sistema ao colapso por baixa tensão, por exemplo. Visto isso, esse trabalho apresenta um método que, através de mudanças adequadas nas grandezas dos geradores determinadas pela análise da matriz de sensibilidade dos controles, permite alcançar um novo perfil de tensão partindo de pontos de operação com problema de adequação das ações de controle por geradores. / [en] Actual recent blackouts which were charactherized by voltage sags suggest that normal process for the voltage control can aggravate the voltage level. It happens because, in special situations, the automatic voltage control has the opposite effect of its logic of conception. In order to identify situations like those, we developed a computational tool to evaluate the effect of voltage control based on the linearized system of power flow equations and selected control equations. The tool calculates the voltage control sensitivity matrix which relates the controlling variables and the controlled voltages of voltage control equipments. The voltage control on synchronous generators is performed by automatic voltage regulators (AVR) that, in practice, have no control logic to differentiate direct and inverse relation between the controlling variable and the excitation voltage of generator. Therefore, if the relation is inverse, the result of the action of the AVR is inadequate (opposite to desired) and may lead the system to collapse due to low voltage, for example. Hence, this paper presents a process to achieve the new voltage profile, starting from operating points with adequacy problems of voltage control actions, through appropriate changes in variables of generators determined by analysis in voltage control sensitivity matrix.
12

Análise do impacto da inserção de novas fontes de energia no nível de afundamentos de tensão utilizando a matriz impedância de barras

Bortolosso, Cassio January 2016 (has links)
Nesta dissertação, é apresentada uma metodologia para cálculo de afundamentos de tensão na presença de fontes alternativas de energia. Um método para determinar o grau de influência da reatância de outras unidades geradoras conectadas ao sistema elétrico no que se refere a afundamentos de tensão é desenvolvido. É utilizada a matriz impedância de barras – Zbus para a obtenção de expressões analíticas para a magnitude de afundamentos de tensão causados por faltas na rede. Uma análise matemática das expressões obtidas e uma análise de sensibilidade são feitas com observações acerca das características propiciadas pela inserção de novas fontes de geração. As expressões analíticas são utilizadas para classificar as barras quanto ao número de afundamentos causados por faltas trifásicas e fase-terra em todas as barras do sistema. De maneira similar, a alocação de uma unidade de geração específica é feita com o objetivo de reduzir o número de afundamentos de tensão observados na rede. As expressões em termos da reatância do gerador são usadas na solução de um conjunto de inequações observando a necessidade da manutenção de níveis mínimos aceitáveis de tensão requisitados por cargas sensíveis, a relação entre a reatância do novo gerador e sua capacidade de mitigação de afundamentos fica evidenciada. / This work presents a methodology for voltage sags analysis in the presence of alternative energy sources. The method determines the degree of influence of the reactance from the new generating units connected to the electrical system with regard to voltage sags magnitudes. The impedance matrix – Zbus is used to obtain analytical expressions voltage sags magnitude caused by faults in the grid. A mathematical analysis of the obtained expressions and a sensitivity analysis are made with observations about the characteristics afforded by the inclusion of new generation sources. The analytical expressions are used to rank the bars as the number of sags caused by three-phase and phase to ground faults on all system buses. Similarly, the allocation of a specific generation unit is done in order to reduce the number of voltage sags over the grid. The expressions in terms of the generator reactance are used on solving a set of inequalities, observing the need to maintain minimum acceptable voltage levels required by sensitive loads, the relationship between the reactance of the new generator and its sag mitigation capability is evidenced.
13

Análise do impacto da inserção de novas fontes de energia no nível de afundamentos de tensão utilizando a matriz impedância de barras

Bortolosso, Cassio January 2016 (has links)
Nesta dissertação, é apresentada uma metodologia para cálculo de afundamentos de tensão na presença de fontes alternativas de energia. Um método para determinar o grau de influência da reatância de outras unidades geradoras conectadas ao sistema elétrico no que se refere a afundamentos de tensão é desenvolvido. É utilizada a matriz impedância de barras – Zbus para a obtenção de expressões analíticas para a magnitude de afundamentos de tensão causados por faltas na rede. Uma análise matemática das expressões obtidas e uma análise de sensibilidade são feitas com observações acerca das características propiciadas pela inserção de novas fontes de geração. As expressões analíticas são utilizadas para classificar as barras quanto ao número de afundamentos causados por faltas trifásicas e fase-terra em todas as barras do sistema. De maneira similar, a alocação de uma unidade de geração específica é feita com o objetivo de reduzir o número de afundamentos de tensão observados na rede. As expressões em termos da reatância do gerador são usadas na solução de um conjunto de inequações observando a necessidade da manutenção de níveis mínimos aceitáveis de tensão requisitados por cargas sensíveis, a relação entre a reatância do novo gerador e sua capacidade de mitigação de afundamentos fica evidenciada. / This work presents a methodology for voltage sags analysis in the presence of alternative energy sources. The method determines the degree of influence of the reactance from the new generating units connected to the electrical system with regard to voltage sags magnitudes. The impedance matrix – Zbus is used to obtain analytical expressions voltage sags magnitude caused by faults in the grid. A mathematical analysis of the obtained expressions and a sensitivity analysis are made with observations about the characteristics afforded by the inclusion of new generation sources. The analytical expressions are used to rank the bars as the number of sags caused by three-phase and phase to ground faults on all system buses. Similarly, the allocation of a specific generation unit is done in order to reduce the number of voltage sags over the grid. The expressions in terms of the generator reactance are used on solving a set of inequalities, observing the need to maintain minimum acceptable voltage levels required by sensitive loads, the relationship between the reactance of the new generator and its sag mitigation capability is evidenced.
14

Análise do impacto da inserção de novas fontes de energia no nível de afundamentos de tensão utilizando a matriz impedância de barras

Bortolosso, Cassio January 2016 (has links)
Nesta dissertação, é apresentada uma metodologia para cálculo de afundamentos de tensão na presença de fontes alternativas de energia. Um método para determinar o grau de influência da reatância de outras unidades geradoras conectadas ao sistema elétrico no que se refere a afundamentos de tensão é desenvolvido. É utilizada a matriz impedância de barras – Zbus para a obtenção de expressões analíticas para a magnitude de afundamentos de tensão causados por faltas na rede. Uma análise matemática das expressões obtidas e uma análise de sensibilidade são feitas com observações acerca das características propiciadas pela inserção de novas fontes de geração. As expressões analíticas são utilizadas para classificar as barras quanto ao número de afundamentos causados por faltas trifásicas e fase-terra em todas as barras do sistema. De maneira similar, a alocação de uma unidade de geração específica é feita com o objetivo de reduzir o número de afundamentos de tensão observados na rede. As expressões em termos da reatância do gerador são usadas na solução de um conjunto de inequações observando a necessidade da manutenção de níveis mínimos aceitáveis de tensão requisitados por cargas sensíveis, a relação entre a reatância do novo gerador e sua capacidade de mitigação de afundamentos fica evidenciada. / This work presents a methodology for voltage sags analysis in the presence of alternative energy sources. The method determines the degree of influence of the reactance from the new generating units connected to the electrical system with regard to voltage sags magnitudes. The impedance matrix – Zbus is used to obtain analytical expressions voltage sags magnitude caused by faults in the grid. A mathematical analysis of the obtained expressions and a sensitivity analysis are made with observations about the characteristics afforded by the inclusion of new generation sources. The analytical expressions are used to rank the bars as the number of sags caused by three-phase and phase to ground faults on all system buses. Similarly, the allocation of a specific generation unit is done in order to reduce the number of voltage sags over the grid. The expressions in terms of the generator reactance are used on solving a set of inequalities, observing the need to maintain minimum acceptable voltage levels required by sensitive loads, the relationship between the reactance of the new generator and its sag mitigation capability is evidenced.
15

Análise da qualidade da energia em um sistema elétrico de distribuição / Power quality analysis in an electrical system distribution

Figueiredo, Pio Antonio de 18 November 2004 (has links)
O trabalho ressalta a importância do tema Qualidade da Energia (QE) e apresenta alguns dos diversos distúrbios responsáveis pelo seu comprometimento. Tais distúrbios, quando presentes em um dado sistema elétrico, podem causar sérios danos tanto aos equipamentos de medição e controle pertencentes ao fornecedor de energia, como também aos equipamentos mais sensíveis pertencentes aos usuários deste sistema. Os fenômenos mais freqüentes no estudo da QE foram destacados, bem como suas definições. Conhecidos estes fenômenos, implementou-se um algoritmo computacional, utilizando como ferramenta a transformada rápida de Fourier janelada (Windowed Fast Fourier Transform - WFFT) - TRFJ, para identificar e classificar estas perturbações em um dado sistema elétrico de distribuição. Para que o resultado fosse o mais próximo possível de uma situação real, utilizou-se para análise, um sistema elétrico real de distribuição da CPFL (Companhia Paulista de Força e Luz). Sobre o referido sistema elétrico foram simulados casos de afundamentos, elevações e oscilações de tensão, criando assim, um banco de dados para, posteriormente, podermos testar e validar o algoritmo computacional implementado, na identificação destes fenômenos. Este algoritmo permite variarmos tanto o tamanho da janela, quanto a freqüência amostral do sinal. Neste estudo em particular, utilizamos tamanhos de janelas de 1 ciclo e 1/2 ciclo, e freqüência amostral do sinal, de 7,68 kHz (inicialmente utilizada para obtenção do banco de dados), e 0,769 kHz, aproximadamente. Como resultados, obtivemos que o tamanho da janela de dados para esta implementação, não apresentou diferenças significativas na análise, quando comparados com os dados iniciais. Entretanto, observa-se um comportamento contrário com a variação da taxa amostral, ou seja, quanto menor a freqüência amostral empregada, maior a perda de informações importantes em relação ao sinal inicial. / The present work at lines the importance of Power Quality (PQ) and it presents some of the many disturbances related to it and its implications. Such disturbances, as presented in an electrical system, can cause serious damages in the measurements, in the control of power utility equipments, as well as in sensitive equipments. The most frequent phenomena in the study of PQ had been emphasized, as well as its definitions. Once these phenomena are known, a computational algorithm was implemented, using the Windowed Fast Fourier Transform - WFFT as a tool to identify and classify these disturbances, considering electrical distribution system. In order to have the best situation for the test, a real electrical distribution system from CPFL (Companhia Paulista de Força e Luz) utility was simulated. Some cases of voltage sag, voltage swell and oscillatory transient were simulated, creating a data base to test and validate the computational algorithm implemented. This algorithm allows changing the window length as the sample rate. For the proposed study, 1 cycle and 1/2 cycle as window length was analyzed with sample rate of 7,68 kHz (initially used for obtaining the data base), and 0,769 kHz. It was observed that the window length studied did not influence significantly the proposed analysis concerning PQ. However, concerning the sample rate, it was observed a deterioration of the analysis with the 0,769 kHz rate.
16

Análise da qualidade da energia em um sistema elétrico de distribuição / Power quality analysis in an electrical system distribution

Pio Antonio de Figueiredo 18 November 2004 (has links)
O trabalho ressalta a importância do tema Qualidade da Energia (QE) e apresenta alguns dos diversos distúrbios responsáveis pelo seu comprometimento. Tais distúrbios, quando presentes em um dado sistema elétrico, podem causar sérios danos tanto aos equipamentos de medição e controle pertencentes ao fornecedor de energia, como também aos equipamentos mais sensíveis pertencentes aos usuários deste sistema. Os fenômenos mais freqüentes no estudo da QE foram destacados, bem como suas definições. Conhecidos estes fenômenos, implementou-se um algoritmo computacional, utilizando como ferramenta a transformada rápida de Fourier janelada (Windowed Fast Fourier Transform - WFFT) - TRFJ, para identificar e classificar estas perturbações em um dado sistema elétrico de distribuição. Para que o resultado fosse o mais próximo possível de uma situação real, utilizou-se para análise, um sistema elétrico real de distribuição da CPFL (Companhia Paulista de Força e Luz). Sobre o referido sistema elétrico foram simulados casos de afundamentos, elevações e oscilações de tensão, criando assim, um banco de dados para, posteriormente, podermos testar e validar o algoritmo computacional implementado, na identificação destes fenômenos. Este algoritmo permite variarmos tanto o tamanho da janela, quanto a freqüência amostral do sinal. Neste estudo em particular, utilizamos tamanhos de janelas de 1 ciclo e 1/2 ciclo, e freqüência amostral do sinal, de 7,68 kHz (inicialmente utilizada para obtenção do banco de dados), e 0,769 kHz, aproximadamente. Como resultados, obtivemos que o tamanho da janela de dados para esta implementação, não apresentou diferenças significativas na análise, quando comparados com os dados iniciais. Entretanto, observa-se um comportamento contrário com a variação da taxa amostral, ou seja, quanto menor a freqüência amostral empregada, maior a perda de informações importantes em relação ao sinal inicial. / The present work at lines the importance of Power Quality (PQ) and it presents some of the many disturbances related to it and its implications. Such disturbances, as presented in an electrical system, can cause serious damages in the measurements, in the control of power utility equipments, as well as in sensitive equipments. The most frequent phenomena in the study of PQ had been emphasized, as well as its definitions. Once these phenomena are known, a computational algorithm was implemented, using the Windowed Fast Fourier Transform - WFFT as a tool to identify and classify these disturbances, considering electrical distribution system. In order to have the best situation for the test, a real electrical distribution system from CPFL (Companhia Paulista de Força e Luz) utility was simulated. Some cases of voltage sag, voltage swell and oscillatory transient were simulated, creating a data base to test and validate the computational algorithm implemented. This algorithm allows changing the window length as the sample rate. For the proposed study, 1 cycle and 1/2 cycle as window length was analyzed with sample rate of 7,68 kHz (initially used for obtaining the data base), and 0,769 kHz. It was observed that the window length studied did not influence significantly the proposed analysis concerning PQ. However, concerning the sample rate, it was observed a deterioration of the analysis with the 0,769 kHz rate.
17

INVESTIGAÇÃO CRÍTICA DA QUALIDADE DA ENERGIA ELÉTRICA DISPONÍVEL NA SUBESTAÇÃO DO CENTRO DE LANÇAMENTO DE ALCÂNTARA / CRITICAL RESEARCH OF THE QUALITY OF ELECTRIC POWER AVAILABLE IN THE SUBSTATION OF ALCÂNTARA LAUNCH CENTRE

Cruz, Harnoldo Castro 14 December 2012 (has links)
Made available in DSpace on 2016-08-17T14:53:23Z (GMT). No. of bitstreams: 1 Dissertacao Harnoldo Castro.pdf: 2052364 bytes, checksum: 3ff44ce616ef2f1e748c29067008a2d1 (MD5) Previous issue date: 2012-12-14 / This work investigates electromagnetic disturbances that affect the power quality of the Alcântara Launch Center (CLA), supplied by the local power distribution utility company and the self-generation of the Center, emphasizing disturbances for sensitivity of electrical ground support equipment, variations in voltage and short-term transients. From a bibliographical study, the main electromagnetic phenomen apresented are related to the power quality, showing the causes, consequences and suggestions for mitigation of these events, including the reduction of inrush current, based on standard norms related to the subject. The monitoring was performed using an accurate monitoring equipment during a two-rocket launch campaign, for a better contextualization ofvoltage variations associated to short-term transients. From the records and gathered data, critical events and power quality indices associated to the distribution utility and to the generation set were analyzed, as well as the severe disturbances characterized by CBEMA curve. The results provided subsidies to improve and reduce the effects of voltage short-term and transient events. Thus an operating procedure for special processes is proposed, which can be used both in the aerospace sector as in organizations that have their processes associated to power quality. / O presente trabalho investiga distúrbios eletromagnéticos que afetam a qualidade da energia elétrica do Centro de Lançamento de Alcântara, suprido pela companhia elétrica local e pela autogeração do próprio Centro, enfatizando os distúrbios críticos para a sensibilidade elétrica dos equipamentos de apoio em solo, as variações de tensão de curta duração e os transitórios. A partir de um estudo bibliográfico, são apresentados os principais fenômenos eletromagnéticos relacionados à qualidade da energia elétrica, mostrando as causas, consequências e sugestões para mitigar tais eventos, com destaque para a redução da corrente de energização, com base nas normas internacionais relacionadas ao tema. O monitoramento foi realizado utilizando-se um equipamento de precisão durante a campanha de lançamento de dois foguetes, para melhor contextualizar as variações de tensão de curta duração e os transitórios. A partir dos registros e dados coletados foram analisados os eventos críticos e os indicadores de tensão da distribuidora local de energia elétrica, e da autogeração de energia do Centro, bem como as graves perturbações caracterizadas com a curva CBEMA. Os resultados obtidos forneceram subsídios para reduzir os efeitos dos eventos da variação de tensão de curta duração e transitórios. Assim propõe-se um procedimento operacional para processos especiais, que poderá ser usado tanto no setor aeroespacial quanto nas organizações que tenham seus processos atrelados à qualidade da energia elétrica.
18

Estudo da capacidade LVRT de sistemas eólicos com DFIG durante a ocorrência de faltas elétricas /

Costa, Christielly Fernandes da January 2020 (has links)
Orientador: André Luiz Andreoli / Resumo: Nos últimos anos, questões relacionadas ao meio ambiente, principalmente, ao uso de combustíveis fósseis e à emissão de gases poluentes na atmosfera, ganharam grande destaque internacional. Com os avanços da comunidade científica e o aumento no preço do petróleo no começo da década de 1970, o uso de fontes renováveis, não poluentes e limpas teve grande investimento por parte de diversos países. Nesse contexto, a geração eólica vem se destacando como uma das mais promissoras, especialmente devido a sua viabilidade econômica e ao seu rápido desenvolvimento tecnológico. Entre as diferentes topologias utilizadas nos sistemas de geração eólica, destaca-se a configuração elaborada para operação em velocidade variável, que emprega o gerador de indução duplamente alimentado (DFIG), associado ao conversor eletrônico back-to-back para controle de sua operação. Como principais vantagens da utilização do DFIG, destacam-se sua maior eficiência na conversão de energia, menor estresse mecânico do rotor, controle independente de potência ativa e reativa limitada a valores típicos de 30% da potência nominal. Por outro, sabe-se que, durante a ocorrência de um distúrbio, as correntes do rotor podem atingir altas magnitudes e causar danos ao conversor. Além disso, sobretensões no capacitor do elo CC ocorrem devido à perda de capacidade de transferência de energia do conversor do lado da rede. Entretanto, os aerogeradores podem ser requisitados a permanecerem em funcionamento mesmo durante uma fa... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: In the last years, issues related to the environment, especially the use of fossil fuels and the emission of polluting gases into the atmosphere, have gained great international prominence. With the advances of scientific community and the increase of the oil price in the beginning of the 1970s, the use of renewable, non-polluting and clean sources had a great investment by several countries. In this context, wind generation has stood out as one of the most promising, especially due to its economic viability and its fast technological development. Among the different topologies used in wind generation systems, the configuration developed for operation at variable speed is highlighted, which employs the doubly-fed induction generator (DFIG) associated with back-to-back electronic converter to control its operation. The main advantages of using DFIG include its greater efficiency in energy conversion, less mechanical rotor stress, independent control of active and reactive power limited to typical values of 30% of the rated power. On the other hand, it is known that, during the occurrence of a disturbance, such as an electrical fault, the rotor currents can reach high magnitudes in order to damage the rotor side converter. In addition, overvoltages in the DC link capacitor occur due to the loss of power transfer capacity on grid side converter. However, wind turbines may be required to main in operation even during a fault, in addition to contributing the restoration of voltage... (Complete abstract click electronic access below) / Mestre
19

AVALIAÇÃO PROBABILÍSTICA DO IMPACTO DA GERAÇÃO DISTRIBUÍDA EÓLICA NOS AFUNDAMENTOS DE TENSÃO DE CURTA DURAÇÃO. / PROBABILISTIC ASSESSMENT OF THE IMPACT OF DISTRIBUTED GENERATION WIND POWER IN THE SHORT TERM VOLTAGE SAGS .

SILVA, Tiago Alencar 09 November 2012 (has links)
Submitted by Maria Aparecida (cidazen@gmail.com) on 2017-08-29T13:12:16Z No. of bitstreams: 1 Tiago Silva.pdf: 3175763 bytes, checksum: 8eba0f17a1a1f6fa2606a5235969987e (MD5) / Made available in DSpace on 2017-08-29T13:12:16Z (GMT). No. of bitstreams: 1 Tiago Silva.pdf: 3175763 bytes, checksum: 8eba0f17a1a1f6fa2606a5235969987e (MD5) Previous issue date: 2012-11-09 / CNPQ / The Distributed Generation (DG) can improve the power quality indices associated with Short Duration Voltage Variations (SDVV) due to the reduction in the electric network loading, which in turn causes an improvement in the pre-fault voltage profile. On the other hand, the DG can also deteriorates the power quality indices related to SDVV due to the increasing in the fault currents, which in turns reduce the post-fault voltages. Furthermore, the assessment of the DG impact on SDVV is more difficult with the presence of renewable energy resources. This complexity is due to fluctuations in output power caused by stochastic variations in the primary energy source (sun, wind, tide levels, etc.). Additionally, the bibliographical review on Predictive Assessment of Short Duration Voltage Variations (PAVV) revealed that none of the existing methodology considered the impact of fluctuations in the output power of a wind DG on power quality indices related to SDVV. It was also noticed that the load variations during the study period are ignored in the papers on SDVV. The existence of these deficiencies and the governmental incentives for the use of wind generation motivated this research. The main aim of this dissertation is the development of a methodology for the PAVV capable of recognizing uncertainties associated with wind DG and load fluctuations. The modeling of these uncertainties was carried out using NonSequential Monte Carlo Simulation (MCS). The nodal voltages in the fault scenarios generated by MCS were evaluated using the Admittance Summation Method (ASM) in phase coordinates. The combination of the MCS with the ASM allowed estimating the following indices related to SDVV: the expected value of the SARFI (“System Average RMS – Variation – Frequency Index”) and expected nodal frequency of SDVV. Furthermore, the probability distributions and box plots of the SARFI index have been obtained. The proposed method for the PAVV was tested and validated in a test system with 32 buses. The tests results demonstrated that the DG insertion causes an improvement in the power quality indices associated with SDVV. Additionally, the substitution of conventional DG by wind DG cause a small deterioration in the power quality indices related to SDVV due to fluctuations in the output power of the wind DG. Finally, it was observed that the load fluctuations during the study period cause significant variations in the SARFI index. / A Geração Distribuída (GD) pode melhorar os índices de qualidade de energia associados com as Variações de Tensão de Curta Duração (VTCD) devido a redução no carregamento da rede elétrica, que por sua vez causa uma melhoria no perfil de tensão pré- falta. Por outro lado, a GD também pode degradar os índices de qualidade de energia associados com VTCD devido ao aumento nas correntes de falta, que por sua vez reduzem as tensões pós-falta. Além disso, a avaliação do impacto da DG sobre VTCD é mais difícil com a presença de fontes de energia renováveis. Esta complexidade se deve as flutuações na potência de saída causadas pelas variações estocásticas na fonte de energia primária (sol, vento, níveis de maré, etc.). Adicionalmente, a revisão bibliográfica realizada sobre Avaliação Preditiva de VTCD (APVT) revelou que nenhuma metodologia existente considerou o impacto de flutuações na potência de saída de geradores eólicos nos índices de qualidade referentes às VTCD. Também foi observado que flutuações de carga ao longo do período de estudo são desconsideradas nos artigos sobre APVT. A existência destas deficiências nos métodos de APVT e os incentivos governamentais para o uso de geração eólica motivaram esta pesquisa. O principal objetivo desta dissertação é o desenvolvimento de uma metodologia para a APVT capaz de reconhecer as incertezas associadas com a GD eólica e flutuações de carga. A modelagem destas incertezas na APVT foi realizada através do uso da Simulação Monte Carlo (SMC) não-sequencial. As tensões nodais nos cenários de falta gerados pela Simulação Monte Carlo (SMC) foram calculadas usando-se o Método de Soma de Admitância (MSA) em coordenadas de fase. A combinação da SMC com o MSA permitiu estimar os seguintes índices probabilísticos relacionados com as VTCD: valor esperado do SARFI (“System Average RMS – Variation – Frequency Index”) e frequência nodal esperada de VTCD. Além disso, foram obtidas distribuições de probabilidade e diagramas de caixa associados com o SARFI. O método proposto nesta dissertação para a APVT foi testado em uma rede de distribuição de 32 barras. Os resultados dos testes mostram que a inserção de GD causa uma melhoria nos índices de qualidade associados com as VTCD. Adicionalmente, a substituição de GD convencional por GD eólica causa uma pequena deterioração nos índices de qualidade referentes às VTCD devido as flutuações na potência de saída da GD eólica. Finalmente, também foi observado que as flutuações na carga ao longo do período de estudo causam variações significativas no índice SARFI.
20

Estudo da deformação permanente de três solos típicos de subleitos rodoviários de Santa Maria - RS / Permanent deformation study about trhee typical road subgrade soils from Santa Maria

Zago, João Paulo 24 November 2016 (has links)
Studies conducted in 2016 show that 58% of the highways in Brazil presents any deficiency in the pavement, signaling or in its geometry. These deficiencies are, on average, the cause for about 6% of the accidents and for the increase of the operational cust by 91,6%. Among them we can stress the permanent deformation, the so called wheel tracks, which is harmful to the dynamic of the loads, to the comfort provided by the pavement, increasing its risk. To the correct design of the pavement it is very important to better know the characteristics of the materials to be used. In this context, stands out the subgrade, the foundation for the whole structure of the pavement, which one is studied in the present reseach by considering three typical soils used as highway subgrade in Santa Maria, Rio Grande do Sul State, and having the permanent deformations as the main focus. The metodology aplied in this work consisted in the location, sampling and characterization of the soil fields, lab tests and empirical machanistic design. Besides the physical, chemical and mechanical characterizations, it was performed the repeated triaxial load test aiming to obtain the resilient modulus and the permanent deformation parameters, according to the Brazilian Petroleum Corporation Manual (PETROBRAS). The Resilient Modulus model presented the better results with frequencies of 1 Hz and 2 Hz, and the presence of silt in one of the soils affected its resilient behaviour. The permanent deformation tests were performed with the frequency of 2 Hz and 150.000 load cicles. The average statistic correlation, according to Guimaraes (2009)´s methodology, was 0.91, bigger than the one provided by the Monismith and Barksdale´s models. However, the dominance of fine grained soils, along with low compactation energy, lead to a higher deformation rates, motivating the use of intermediate energy. With this new approach the permanent deformation was reduced 40% and the resilient modulus increased 78,8%. However, the numerical simulation according to the mechanistic approach, and using the layer thickness obtained from the Departamento Nacional de Infraestrutura de Transportes (DNIT) method, under 8,2 ton standard axle load, showed that the wheel tracks deeping would be small, based on the low stresses observed in the subgrade. On the other hand, the fatigue behaviour presented an inferior performance, reducing the project´s useful life. It was observed the presence of shakedown in the ranges A, B and C. / Pesquisas realizadas no ano de 2016 mostram que 58,2 % das rodovias de todo o país apresentam alguma deficiência no pavimento, na sinalização ou na geometria da via. Em média, esses defeitos são responsáveis por cerca de 6% do número de acidentes, além de aumentar o custo operacional das vias em até 91,6%. Dentre essas anomalias, destaca-se a deformação permanente denominada de afundamento na trilha de roda (ATR), que prejudica a dinâmica das cargas, afeta o conforto ao rolamento e causa risco à segurança. Para o adequado dimensionamento de um pavimento, é fundamental o conhecimento dos materiais que o compõem. Neste contexto, destaca-se o subleito, por ser a fundação sobre a qual são assentes todas as camadas, motivo pelo qual o objetivo geral desta pesquisa é analisar três solos típicos de subleitos rodoviários de Santa Maria, estado do Rio Grande do Sul, em especial quanto aos parâmetros de deformação permanente. A metodologia aplicada neste trabalho consistiu na localização, coleta e caracterização das jazidas de solos, realização de ensaios laboratoriais e dimensionamento mecanístico - empírico. Assim, além da caracterização física, química e mecânica, foram realizados ensaios triaxiais de cargas repetidas para obtenção do módulo de resiliência e dos parâmetros de deformação permanente, segundo recomendações do manual de execução de trechos monitorados da empresa Petróleo Brasileiro Sociedade Anônima (PETROBRAS). O modelo composto do módulo de resiliência apresentou os melhores resultados, a partir de ensaios com frequência de 1 Hz e 2 Hz, sendo que a presença de silte em um dos solos afetou seu comportamento resiliente. Os ensaios de deformação permanente foram conduzidos a 2 Hz, com 150.000 ciclos de aplicação de carga, cuja correlação estatística média, empregando a metodologia de Guimarães (2009), foi de 0,91 – superior a dos modelos de Monismith e Barksdale. Entretanto, a predominância de materiais finos, aliada à baixa energia de compactação (normal), resultaram em elevadas taxas de deformação, o que motivou o estudo de um dos solos também com uso da energia intermediária. Esse procedimento reduziu a deformação permanente em 40% e elevou o módulo de resiliência em 78,8%. Entretanto, a simulação numérica do pavimento sob a ótica mecanicista, a partir das espessuras calculadas pelo método do Departamento Nacional de Infraestrutura de Transportes (DNIT), aplicando-se a carga padrão de 8,2 toneladas, mostrou que o ATR seria pequeno, em face das baixas tensões atuantes no subleito, em contraposição ao desempenho à fadiga, que reduziu sensivelmente a vida útil de projeto. Constatouse a ocorrência de shakedown nos domínios A, B e C.