• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • 1
  • Tagged with
  • 4
  • 4
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Caracterização de uma câmara de ionização ar-livre em feixes diretos de raios X utilizados em mamografia / Characterization of a free-air ionization chamber in direct X-ray beams as used in mammography

Lima, Mateus Hilário de 24 February 2014 (has links)
Neste trabalho foram realizados testes de estabilidade e de caracterização de uma câmara de ionização de ar-livre com cilindros concêntricos da marca Victoreen, modelo 481. Os testes foram feitos utilizando feixes diretos de mamografia como uma contribuição para a implantação desta câmara como sistema padrão primário para a grandeza kerma no ar. Os testes de caracterização realizados foram: curva de saturação, eficiência de coleção de íons, efeito de polaridade, linearidade da resposta com a taxa de kerma no ar e linearidade da resposta com a variação volumétrica. O teste de eficiência de coleção de íons possibilitou a determinação do fator de correção para recombinação iônica. A maioria dos testes realizados esteve em conformidade com os limites estabelecidos por normas internacionais. Foram obtidos os fatores de correção para atenuação de fótons no ar para as qualidades de mamografia com filtros de alumínio e molibdênio. Foram determinados também os fatores de correção para transmissão e espalhamento de fótons nas bordas do diafragma para as qualidades de mamografia com filtro de alumínio e para a qualidade padrão de mamografia com filtro de molibdênio. / At this work stability and characterization tests were undertaken on a Victoreen free-air ionization chamber, model 481. The tests were realized using direct X-ray beams as a contribuition for its establishment as a primary standard system of the quantity air kerma. The characterization tests were: saturation curve, ion collection efficiency, polarity effect, response linearity with the air kerma rate and response linearity with the chamber volume variation. The ion collection efficiency allowed the determination of the ion recombination factor. Most of the test results showed agreement with the limits established by international standards. Furthermore, the air attenuation factors for the mammography beams with aluminum and molybdenum filters were obtained. The factors for photon transmission and scattering at the diaphragm edges were also determined for mammography beams with aluminum filter and for the standard beam with molybdenum filter.
2

Caracterização de uma câmara de ionização ar-livre em feixes diretos de raios X utilizados em mamografia / Characterization of a free-air ionization chamber in direct X-ray beams as used in mammography

Mateus Hilário de Lima 24 February 2014 (has links)
Neste trabalho foram realizados testes de estabilidade e de caracterização de uma câmara de ionização de ar-livre com cilindros concêntricos da marca Victoreen, modelo 481. Os testes foram feitos utilizando feixes diretos de mamografia como uma contribuição para a implantação desta câmara como sistema padrão primário para a grandeza kerma no ar. Os testes de caracterização realizados foram: curva de saturação, eficiência de coleção de íons, efeito de polaridade, linearidade da resposta com a taxa de kerma no ar e linearidade da resposta com a variação volumétrica. O teste de eficiência de coleção de íons possibilitou a determinação do fator de correção para recombinação iônica. A maioria dos testes realizados esteve em conformidade com os limites estabelecidos por normas internacionais. Foram obtidos os fatores de correção para atenuação de fótons no ar para as qualidades de mamografia com filtros de alumínio e molibdênio. Foram determinados também os fatores de correção para transmissão e espalhamento de fótons nas bordas do diafragma para as qualidades de mamografia com filtro de alumínio e para a qualidade padrão de mamografia com filtro de molibdênio. / At this work stability and characterization tests were undertaken on a Victoreen free-air ionization chamber, model 481. The tests were realized using direct X-ray beams as a contribuition for its establishment as a primary standard system of the quantity air kerma. The characterization tests were: saturation curve, ion collection efficiency, polarity effect, response linearity with the air kerma rate and response linearity with the chamber volume variation. The ion collection efficiency allowed the determination of the ion recombination factor. Most of the test results showed agreement with the limits established by international standards. Furthermore, the air attenuation factors for the mammography beams with aluminum and molybdenum filters were obtained. The factors for photon transmission and scattering at the diaphragm edges were also determined for mammography beams with aluminum filter and for the standard beam with molybdenum filter.
3

Exposure Monitoring and Dosimetry - Optimizing Radiation Protection in Interventional Cardiology / Exponeringsanalys och Dosimetri - Optimering av praktiskt strålskydd inom interventionell kardiologi

Pettersson, Amanda January 2023 (has links)
During interventional cardiology (IC), medical staff are exposed to scattered ionizing radiation from the patient, potentially leading to various radiation-induced health effects. Therefore, shielding devices are routinely used to reduce occupational exposure during IC procedures. This study explores how the positioning of shielding devices impacts radiation protection efficiency in clinical scenarios. The study aims to determine optimal setups and potential pitfalls that might significantly reduce the efficiency of the shielding devices. It also explores the relationship between DICOM-based production data, clinical observations, and phantom-based measurements to add knowledge to the research field of radiation protection in IC. Clinical DICOM-based production data from 4976 procedures were analyzed to identify C-arm projection angles used during different procedure types. This data and the results of an observational study were used to determine a scattered radiation measurement setup. A survey meter was used to measure air kerma at seven heights in the operator position while an anthropomorphic phantom was irradiated. The measurements were distributed over seven projections with 56 position combinations of the shielding devices. A total of 3171 measurements were performed. The measurements suggest significant variations in the operator dose depending on the projection and how the shielding devices are positioned. The most optimal combination of shielding devices was achieved when placing the table-mounted shield along the table, the ceiling-suspended shield caudal close to the phantom, and without the patient drape. Conversely, the least optimal combination was achieved when placing the table-mounted shield flared out, the ceiling-suspended shield cranial 10 cm above the phantom, and without the patient drape. The air kerma rate for these two shielding setups with the LAO25/CAUD30 projection was reduced from 0.19 μGy/s to 0.05 μGy/s at 110 cm from the floor. This height was shown to be the hardest to properly shield. Despite the implementation of the most optimal shielding combination, it is evident that certain heights present difficulties in effectively protecting the operator from scattered radiation.
4

Avaliação dosimétrica de protocolos de exame de tomografia computadorizada de feixe cônico

Soares, Maria Rosangela 22 January 2016 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / This PhD thesis, addresses the issue of evaluation of cone beam computed tomography, CBCT, scanning protocols, was introduced in dental radiology at the end of the 1990s, and it quickly became a fundamental examination for various procedures. Its main characteristic, the difference of medical CT is the beam shape. This study aimed to calculate the absorbed dose in eight tissues / organs of the head and neck, and to estimate the effective dose in 13 protocols and two techniques (stitched FOV e single FOV) of 5 equipment of different manufacturers of cone beam CT. For that purpose, a female anthropomorphic phantom was used, representing a default woman, in which were inserted thermoluminescent dosimeters at several points, representing organs / tissues with weighting values presented in the standard ICRP 103. The results were evaluated by comparing the dose according to the purpose of the tomographic image. Among the results, there is a difference up to 325% in the effective dose in relation to protocols with the same image goal. In relation to the image acquisition technique, the stitched FOV technique resulted in an effective dose of 5.3 times greater than the single FOV technique for protocols with the same image goal. In the individual contribution, the salivary glands are responsible for 31% of the effective dose in CT exams. The remaining tissues have also a significant contribution, 36%. The results drew attention to the need of estimating the effective dose in different equipment and protocols of the market, besides the knowledge of the radiation parameters and equipment manufacturing engineering to obtain the image. / Na presente tese de doutoramento foi abordada a temática da avaliação de protocolos de exame de tomografia computadorizada de feixe cônico - TCFC, que foi iniciada na radiologia odontológica no fim da década de 1990 e rapidamente tornou-se um exame fundamental para diversos procedimentos. Sua principal característica, que a diferencia da tomografia computadorizada médica, é a forma do feixe. Assim, este estudo objetivou calcular a dose absorvida em 8 tecidos/órgãos da cabeça e pescoço e estimar a dose efetiva em 13 protocolos e duas técnicas (stitched FOV e single FOV) de 5 equipamentos diferentes fabricantes de tomografia computadorizada de feixe cônico. Para isto, foi utilizado um simulador antropomórfico feminino, representando uma mulher padrão, onde foram inseridos dosímetros termoluminescentes em diversos pontos, representando órgãos e tecidos com valores de ponderação apresentados na norma ICRP 103. Os resultados foram avaliados, comparando-se a dose de acordo com o objetivo da imagem tomográfica. Dentre os resultados, observou-se uma diferença de até 325 % de dose efetiva em relação a protocolos com o mesmo objetivo de imagem. Em relação à técnica de obtenção de imagem, a técnica stitched FOV resultou em uma dose efetiva até 5,3 vezes maior que a single FOV para protocolos com o mesmo objetivo de imagem. Na contribuição individual, as glândulas salivares são responsáveis por 31% da dose efetiva, nos exames tomográficos. Os tecidos restantes também apresentaram uma contribuição significativa, 36 %. Os resultados apontam a necessidade de se estimar a dose efetiva nos diversos equipamentos e protocolos presentes no mercado, além de conhecer os parâmetros de radiação e a engenharia de fabricação dos equipamentos para a obtenção da imagem.

Page generated in 0.0271 seconds