• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 95
  • 4
  • 2
  • Tagged with
  • 101
  • 101
  • 65
  • 63
  • 24
  • 16
  • 16
  • 16
  • 14
  • 14
  • 12
  • 12
  • 11
  • 10
  • 10
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Desenvolvimento de fontes laser, espectroscopia de alta resolução e resfriamento e aprisionamento magneto-óptico de átomos de cálcio

Cavasso Filho, Reinaldo Luiz 27 August 2002 (has links)
Orientador: Flavio Caldas da Cruz / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Fisica Gleb Wataghin / Made available in DSpace on 2018-08-03T02:29:58Z (GMT). No. of bitstreams: 1 CavassoFilho_ReinaldoLuiz_D.pdf: 9595326 bytes, checksum: 91354a90233453257da030ae6ed97640 (MD5) Previous issue date: 2002 / Resumo: Neste trabalho, abordamos o desenvolvimento de um sistema experimental para resfriamento laser e aprisionamento magneto-óptico de átomos de cálcio, o desenvolvimento de fontes laser empregadas nesse sistema, bem como estudos espectroscópicos de transições desse elemento em descargas elétricas de catodo oco. No caso do cálcio, a transição óptica mais eficiente para a manipulação do movimento dos átomos por pressão de radiação é a 1 S0-1 P1 em 423 nm. Uma das fontes de radiação laser que desenvolvemos para esse comprimento de onda consiste de um laser de Ti:Safira estabilizado e duplicado em freqüência. A freqüência desse laser é travada à ressonância de uma cavidade de Fabry-Perot de referência. O segundo harmônico do laser é gerado por conversão não-linear em um cristal de niobato de potássio situado em uma cavidade externa de amplificação. Investigamos o uso de lâmpadas de catodo oco de cálcio como ferramentas espectroscópicas de alta resolução. A variação na impedância da descarga elétrica que ocorre com a excitação laser, o efeito optogalvânico, é uma técnica de alta sensibilidade que simplifica consideravelmente a detecção e a sintonia em transições atômicas muito fracas como a 1 S0-3 P1 em 657 nm. O sistema de resfriamento e aprisionamento de átomos de cálcio é o último tópico abordado neste trabalho. Nesse sistema, átomos provenientes de um feixe atômico térmico são resfriados pela técnica de desaceleração Zeeman e então capturados em uma armadilha magneto-óptica. Empregamos um esquema alternativo de desaceleração Zeeman que usa um feixe laser com a mesma freqüência dos feixes da armadilha. Estudamos a variação do número estacionário de átomos aprisionados com vários parâmetros, como o gradiente de campo magnético, a dessintonia e a intensidade dos feixes laser de aprisionamento e desaceleração. Analisamos também a evolução temporal do número de átomos aprisionados. Esse estudo mostrou que o tempo de armazenamento na armadilha é limitado por perdas devido ao bombeamento óptico de níveis metaestáveis do cálcio. Essas perdas por bombeamento óptico são muito maiores do que as perdas decorrentes de colisões binárias entre os átomos frios. Nesse regime, o comportamento não-exponencial do número de átomos torna-se muito difícil de ser observado. Todavia, constatamos que é possível extrair informações relativas à taxa de perdas por colisões frias comparando as constantes de tempo exponenciais das curvas de carga e descarga / Abstract: In this work, we report on an experimental system for laser cooling and magneto-optical trapping of calcium atoms, the development of the laser sources for this system, and a spectroscopic analysis of calcium transitions in hollow cathode electric discharges. In the case of calcium, the most efficient optical transition for the atom motion manipulation by radiation pressure is the 1 S0- 1 P1 at 423 nm. One of the lasers sources that we developed at this wavelength consists on a frequency doubled and stabilized Ti:Sapphire laser. The frequency of this laser is locked to the resonance of a Fabry-Perot reference cavity. The second harmonic is generated by nonlinear conversion in a potassium niobate crystal inside an external power enhancement cavity. We investigate the use of calcium hollow cathode lamps as high resolution spectroscopic tools. The variation of the electrical discharge caused by the laser excitation, the optogalvanic effect, is a high sensitivity technique that greatly simplifies the detection and tuning on very weak atomic transitions, as the 1 S0-3 P1 at 657 nm. The system for cooling and trapping of calcium atoms is the last topic reported in this work. In this system, atoms from a thermal atomic beam are first cooled by the Zeeman deceleration technique and then trapped on a magneto-optical trap. We employed an alternative scheme for Zeeman deceleration which uses a laser beam at the same frequency of the trapping laser beams. We analyzed the variation of the steady state number of trapped atoms with several parameters, as magnetic field gradient, detuning and intensity of the trapping and decelerating laser beams. We also analyzed the time evolution of the number of trapped atoms. This analysis showed that the trap storage time is limited by losses related with the optical pumping of calcium metastable levels. These optical pumping losses are much larger than the losses caused by binary collisions between the cold atoms. In this regime, the non-exponential behavior of the atom number is very difficult to observe. However, we noticed that it is possible to extract information on the cold collision loss rate by comparing the exponential time constants of the trap load and the decay curves / Doutorado / Física / Doutor em Ciências
12

Lasers de semicondutor de baixo ruído para espectroscopia atômica na região azul do espectro

Manoel, Daniela de Andrade 28 November 2003 (has links)
Orientador: Flavio Caldas da Cruz / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Fisica Gleb Wataghin / Made available in DSpace on 2018-08-03T18:29:50Z (GMT). No. of bitstreams: 1 Manoel_DanieladeAndrade_D.pdf: 3041462 bytes, checksum: 7c1e64a45505d48560d2b1c08bcb85ff (MD5) Previous issue date: 2003 / Resumo: Este trabalho apresenta o desenvolvimento de duas fontes laser na região violeta do espectro para serem usadas em espectroscopia atômica e aprisionamento de átomos de Cálcio. Ambas as fontes são baseadas em lasers de semicondutor com a frequência duplicada. Uma delas utiliza um laser com cavidade estendida e frequência duplicada por um cristal de niobato de potássio colocado em uma cavidade amplificadora. O laser emite em apenas um modo longitudinal com largura de linha estreita (<1 MHz) e pode ser sintonizado continuamente dentro de intervalos de 800 MHz. O ruído de amplitude deste laser está próximo do nível "shot" para frequências acima de 1MHz. Um total de 18 mW de potência útil em ¸ l = 423nm é obtido deste sistema. Esta luz foi utilizada para a desaceleração de átomos de Cálcio de um feixe atômico, posteriormente aprisionados em uma armadilha magneto óptica. A outra fonte de luz violeta é composta de um amplificador semicondutor óptico injetado por uma fração da luz do laser de cavidade estendida. Com a injeção óptica, o amplificador apresenta emissão laser com as mesmas características espectrais do laser injetor, porém com uma potência maior. Este sistema fornece 54 mW de luz em ¸ l = 423 nm / Abstract: This work presents the development of two violet laser sources to be used mainly in atomic spectroscopy and cooling and trapping of Calcium atoms. Both sources are based on frequency doubled semiconductor lasers. One of them uses an extended cavity semiconductor laser, whose frequency is doubled by a potassium niobate crystal placed in a power enhancement cavity. The laser emits in a single longitudinal mode with narrow linewidth and can be continuously tuned within a 800 MHz range. The laser amplitude noise is at the shot noise level for frequencies above 1MHz. A total useful power of 18 mW at ¸ l = 423 nm is obtained from this system. This light is used to decelerate Calcium atoms from an atomic beam, which are captured by a magneto-optical trap. The other violet laser source is composed by a semiconductor amplifier optically injected by a fraction of the power of the extended cavity diode laser. With the optical injection, the amplifiers presents laser emission with the same spectral characteristics of the injecting laser, but with a higher power. Up to 54 mW of violet light is generated from this system / Doutorado / Física / Doutor em Ciências
13

Espectroscopia de alta resolução em sólidos por ressonância magnétoca nuclear. / High resolution spectroscopy in solids for nuclear resonace

Bonagamba, Tito Jose 25 July 1991 (has links)
Este trabalho descreve técnicas de espectroscopia de alta resolução em sólidos por Ressonância Magnética Nuclear (RMN), o projeto de construção de um espectrômetro para este fim e sua avaliação experimental com a utilização deste equipamento na caracterização de amostras sólidas. O espectrômetro de alta resolução em sólidos por RMN desenvolvido, permite a utilização de técnicas de dupla ressonância, múltiplos pulsos e rotação da amostra em tomo do ângulo mágico e pode também ser utilizado para líquidos. A máxima freqüência de rotação para MAS é da ordem de 5KHz e as seqüências de dupla ressonância podem ser utilizadas pala quaisquer pares de núcleos atômicos. Os experimentos podem ser realizados com variação de temperatura de -120&#176C a + 160&#176C e o equipamento é totalmente controlado por um microcomputador Macintosh IIci. / This work describes the nuclear magnetic resonance (NMR) techniques for High Resolution Spectroscopy in Solids. Also, the construction project of a partially \"home made\" spectrometer and its applications in the characterization of solid samples are shown in detail. Our high resolution spectrometer is implemented with the double resonance multiple pulses sequences and magic angle spinning (MAS) and can be used with solid and liquid samples. The maximum spinning frequency for the MAS experiment is in excess of 5KHz, the double resonance sequences can be performed with any type of nucleus, in the variable temperature operating range with nitrogen gas: -120&#176C to +160&#176C, and is fully controlled by a Macintosh IIci microcomputer.
14

Refinamento citogenético em indivíduos com anomalias craniofaciais sindômicas sem diagnóstico definido / Cytogenetic refinement in individuals with syndromic craniofacial anomalies with unkown diagnoses

Rodrigues, Rubens Matias 26 May 2010 (has links)
Objetivos: Investigar possíveis alterações citogenéticas, através da técnica de bandamento de alta resolução, em indivíduos com anomalias craniofaciais associadas ao atraso no desenvolvimento neuropsicomotor e sem diagnóstico clínico-genético definido, com cariótipo (com bandas) prévio normal e estabelecer possível correlação entre o fenótipo dos indivíduos e as regiões cromossômicas alteradas. Local de execução: Laboratório de Citogenética Humana e Serviço de Genética Clínica, HRAC-USP, Bauru-SP. Indivíduos estudados e Resultados: O cariótipo de alta resolução de 16 indivíduos com anomalias craniofaciais associadas ao atraso no desenvolvimento neuropsicomotor pertencentes ao HRAC-USP, Bauru permitiu detectar alterações citogenéticas estruturais em 4 (25%) dos 16 indivíduos. Em 3 indivíduos detectou-se deleções em regiões subteloméricas (cromossomos 4p, 9p e 18q) e, em 1 indivíduo detectou-se adição de segmento cromossômico de origem desconhecida na região telomérica do cromossomo 12p. Conclusões: A frequência alta (25%) de alterações cromossômicas estruturais em regiões cromossômicas terminais (teloméricas e subteloméricas) mostra que a técnica de alta resolução é útil na identificação de alterações nessas regiões, portanto, indivíduos com anomalias craniofaciais e atraso mental, sem diagnóstico genético-clínico definido, cujo cariótipo convencional foi normal, devem ser, submetidos à análise dos cromossomos por meio do cariótipo de alta resolução antes do procedimento de CGHarray. / Objective: To investigate possible cytogenetic abnormalities through high resolution banding technique in individuals with craniofacial anomalies presenting previous normal karyotype, associated to neuropsychological development delay, without clinic-genetic diagnoses, and establish possible correlation between phenotype and possible candidate chromosomal regions. Local: Human Cytogenetic Laboratory and Clinical Genetic Service, HRAC-USP, Bauru, SP. Individuals and Results: High resolution karyotype of 16 individuals with craniofacial anomalies associated to neuropsychological development delay in follow-up at the HRAC-USP, Bauru allowed the detection of structural chromosomal abnormalities in 4 (25%) of them. Three individuals presented deletion in the subtelomeric region (chromosomes 4p, 9p, and 18q), and one individual presented an addition of an unknown chromosomal fragment in the telomeric region of chromosome 12p. Conclusions: The high frequency (25%) of structural chromosomal abnormalities in terminal region (telomeric and subtelomeric) shows that the high resolution technique is useful for identification of structural anomalies in these regions. Therefore, individuals with craniofacial anomalies associated to neuropsychological development delay without a definitive clinic-genetic diagnoses presenting a normal conventional karyotype, should be submitted to chromosomal analysis through high resolution karyotype before CGH-array procedure.
15

Análise direta de mono, di e triacilglicerídeos em biodiesel por cromatografia gasosa de alta resolução: resolução ANP 42 e suas extensões / Analysis of direct mono, di, triacylglyceride into biodiesel by high resolution gas chromatography: the resolution ANP 42 and its extensions

Pelisson, Leidimara 08 July 2008 (has links)
O biodiesel é quimicamente definido como ésteres monoalquílicos de ácidos graxos derivados de óleos vegetais, gorduras animais ou matérias graxas de descarte. O processo mais comumente empregado para a sua produção é a transesterificação catalisada por base. O controle de qualidade do biodiesel produzido é essencial para o aproveitamento deste como combustível. A Agência Nacional de Petróleo (ANP) estabelece diferentes métodos e especificações para a análise de biodiesel. A cromatografia gasosa é a técnica utilizada para a determinação de glicerol livre e ligado. Esta dissertação apresenta os resultados de dois processos de transesterificação para o óleo de soja: reação catalisada por ácido e reação catalisada por base. Os resultados foram avaliados por cromatografia gasosa de alta resolução, tendo sido demonstrado que a reação catalisada por base apresenta melhores resultados. Desenvolveu-se também nesta dissertação uma metodologia para análise de mono, di e triacilglicerídeos, como uma extensão da resolução ANP 42. A metodologia desenvolvida apresentou excelentes resultados para análises de glicerol ligado em amostra de óleos e biodiesel. / Biodiesel is chemically defined as fatty acid mono-alkyl esters derived of vegetable oils, animal fats or discarded greases. The process more commonly employed for biodiesel production is transesterification catalyzed by base. The quality control of the produced biodiesel is essential for its use as fuel. The National Agency of Petroleum (ANP) establishes different methods and specifications for the analysis of biodiesel. The proposed technique for determination of free and bonded glycerol is gas chromatography. This study presents the results of two reactions of transesterification of the soy oil: catalyzed by acid and catalyzed by base. The results were evaluated by high resolution gas chromatography, which demonstrated better results when basic catalysis was employed. A methodology for mono, di and triacylglicerides was also developed in this dissertation, as an extension of the resolution ANP 42. The developed methodology presented excellent results for bonded glycerol analyses in samples of oils and biodiesel.
16

Desenvolvimento de métodos para a determinação de Pb, Cd, Cr, Ni e Sb em cosméticos faciais por espectrometria de absorção atômica em forno de grafite de alta resolução com fonte contínua empregando amostragem direta de sólidos /

Barros, Ariane Isis. January 2016 (has links)
Orientador: José Anchieta Gomes Neto / Coorientador: Edilene Cristina Ferreira / Banca: Paulo Clairmont Feitosa de Lima Gomes / Banca: Clóvis Augusto Ribeiro / Banca: Joaquim de Araujo Nóbrega / Banca: Cassiana Seimi Nomura / Resumo: Este trabalho relata o desenvolvimento de métodos para a determinação de Pb, Cd, Cr, Ni e Sb em cosméticos faciais por espectrometria de absorção atômica em forno de grafite de alta resolução com fonte contínua (HR-CS GF AAS) empregando análise direta de amostras sólidas. Essa técnica foi utilizada devido a sua alta capacidade para a correção de fundo baseada em algoritmos dos mínimos quadrados. Para a determinação de Pb e Sb, interferências causadas por moléculas de SiO(g) nas linhas 283,306 nm (Pb), 217,582 nm (Sb) e 231,147 nm (Sb) foram eliminadas pela aplicação do método de correção de fundo pelos mínimos quadrados (LSBC). Para a correção de fundo na determinação de Pb, o espectro de referência foi gerado a partir de SiO2. Diferentes precursores foram avaliados para geração do espectro de referência para a correção de fundo na determinação de Sb, sendo a zeólita e a mica os precursores mais eficazes. Efeitos de matriz foram avaliados pela comparação das massas características e inclinações das curvas obtidas em padrões aquosos e amostras (ou material de referência certificado). Calibrações com padrões aquosos foram possíveis e curvas com bom coeficiente de correlação (r>0,99) foram obtidas para todos os analitos. Os limites de detecção foram de 0,06 mg kg -1 Pb, 3,67 µg kg-1 Cd, 0,5 mg kg-1 Cr, 0,292 mg kg-1 Ni e 0,32 mg kg-1 Sb. As concentrações dos analitos encontradas em amostras comerciais de blush, sombra de olho e pó compacto variaram de 1,0 - 27,08 mg kg-1 Pb, 5,0... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This work reports on the development of methods for determination of Pb, Cd, Cr, Ni and Sb in facial cosmetics by high-resolution continuum source graphite furnace atomic absorption spectrometry (HR-CS GF AAS) employing direct solid sample analysis. This technique was used due to the high capability for background correction based on least-squares algorithm. For Pb and Sb determinations, interferences caused by SiO(g) molecule at the lines 283.306 nm (Pb), 217.582 nm (Sb) and 231.147 nm (Sb) were eliminated by applying the least-squares background correction (LSBC). For background correction in the determination of Pb, a reference spectrum was generated from SiO2. Different precursors were evaluated to generate reference spectra for correction of the background in the determination of Sb, been zeolite and mica the most effective precursors. Matrix effects were evaluated by comparing the characteristics masses and slopes of curves in aqueous standards and sample (or certified reference material). Calibration with aqueous standards were possible, and curves with good correlation coefficients (r>0.99) were attained for all analytes. The limits of detection were 0.06 mg kg-1 Pb, 3.67 µg kg-1 Cd, 0.5 mg kg-1 Cr, 0.292 mg kg-1 Ni and 0.32 mg kg-1 Sb. The found concentrations of analytes in commercial blush, eye shadow and compact powder samples were within 1.0 - 27.08 mg kg-1 Pb, 5.06 - 198.20 µg kg-1 Cd, 2.87 - 23.65 mg kg-1 Cr, 1.36 - 12.09 mg kg-1 Ni, and 9.14 - 14.52 mg kg-1 Sb... (Complete abstract click electronic access below) / Doutor
17

Espectrometria de absorção atômica e molecular de alta resolução com fonte contínua e forno de grafite : possibilidades e aplicações analíticas

Boschetti, Wiliam January 2016 (has links)
Este trabalho apresenta o desenvolvimento de métodos analíticos que exploram inovações trazidas pela espectrometria de absorção atômica e molecular de alta resolução com fonte contínua (HR-CS AAS e MAS): corrigir interferências espectrais (atômicas e moleculares), realizar determinações multielementares (sequenciais e/ou simultâneas) e determinar a concentração de elementos através de moléculas diatômicas. A alta resolução da técnica, aliada ao uso do forno de grafite, possibilita a análise direta de amostras sólidas e líquidas. As temperaturas utilizadas, em cada método desenvolvido, foram otimizadas visando sinais analíticos com alta sensibilidade e livres de interferências. Dois métodos foram desenvolvidos para determinar Mo e Ni, simultaneamente, em amostras de fertilizantes e vinhos. Paralelamente foi desenvolvido um método para determinar Si em amostras de plantas. Foi desenvolvido, também, um método para determinação sequencial e simultânea de Cd, Cr, Fe e Al em amostras de solo. Ainda considerando amostras de solo, um método para determinar a concentração de F foi desenvolvido utilizando a molécula diatômica de CaF. Os métodos apresentados demonstraram que as técnicas HR-CS GF AAS e MAS permitem analisar amostras de alta complexidade com mínimo pré-tratamento, realizar determinações multielementares e moleculares e empregar linhas analíticas alternativas. / This work presents the development of analytical methods that explore the innovations reached by high-resolution continuum source atomic and molecular absorption spectrometry (HR-CS AAS and MAS): to correct spectral interferences (atomic and molecular), to perform multielement determinations (sequentially and/or simultaneously), and even to use diatomic molecules in order to determine analyte concentrations. The high-resolution of the technique, combined with the use of the graphite furnace, made possible the direct analysis of solid and liquid samples. The temperatures used in each method were optimized aiming for analytical signals with high sensitivity and free of interferences. Two methods were developed to determine Mo and Ni, simultaneously, in fertilizers and wine samples. A method was developed to determine Si in plant samples. A method for sequential and simultaneous determination of Cd, Cr, Fe and Al in soil samples was also developed. Still considering the soil samples, a method for F determination was developed using the CaF diatomic molecule. All methods demonstrate that the HR-CS GF AAS and MAS techniques allow highly complex samples analysis with minimal pretreatment, enabling multielement and molecular determinations employing also alternative analytical lines.
18

Espectroscopia de alta resolução em sólidos por ressonância magnétoca nuclear. / High resolution spectroscopy in solids for nuclear resonace

Tito Jose Bonagamba 25 July 1991 (has links)
Este trabalho descreve técnicas de espectroscopia de alta resolução em sólidos por Ressonância Magnética Nuclear (RMN), o projeto de construção de um espectrômetro para este fim e sua avaliação experimental com a utilização deste equipamento na caracterização de amostras sólidas. O espectrômetro de alta resolução em sólidos por RMN desenvolvido, permite a utilização de técnicas de dupla ressonância, múltiplos pulsos e rotação da amostra em tomo do ângulo mágico e pode também ser utilizado para líquidos. A máxima freqüência de rotação para MAS é da ordem de 5KHz e as seqüências de dupla ressonância podem ser utilizadas pala quaisquer pares de núcleos atômicos. Os experimentos podem ser realizados com variação de temperatura de -120&#176C a + 160&#176C e o equipamento é totalmente controlado por um microcomputador Macintosh IIci. / This work describes the nuclear magnetic resonance (NMR) techniques for High Resolution Spectroscopy in Solids. Also, the construction project of a partially \"home made\" spectrometer and its applications in the characterization of solid samples are shown in detail. Our high resolution spectrometer is implemented with the double resonance multiple pulses sequences and magic angle spinning (MAS) and can be used with solid and liquid samples. The maximum spinning frequency for the MAS experiment is in excess of 5KHz, the double resonance sequences can be performed with any type of nucleus, in the variable temperature operating range with nitrogen gas: -120&#176C to +160&#176C, and is fully controlled by a Macintosh IIci microcomputer.
19

Quantificação da resoluçao do sistema SPECT-CZT através do uso da função de transferência modulada (MTF) /

Zandona, Ednaldo Alexandre. January 2013 (has links)
Orientador: José Ricardo de Arruda Miranda / Banca: José Roberto Saglieti / Banca: Eder Rezende Moraes / Resumo: A medicina nuclear é uma especialidade médica que se ocupa de técnicas de imagem para observar o estado fisiológico dos tecidos ou órgãos de forma não invasiva, através da marcação de moléculas participantes desses processos, com isótopos radioativos, originando assim os chamados radionuclídeos. O SPECT é um equipamento que se utiliza de imagens planares, obtidas de vários ângulos ao redor do objeto de interesse, e, através de algoritmos computacionais, obtêm uma imagem tomográfica dessas projeções. Sua origem remete há aproximadamente cinquenta anos atrás, com criação da Câmara Anger (Hall Anger, 1964). Durante todo esse tempo, embora tenha havido alguma evolução, a estrutura dessas gama câmaras praticamente ficou Inalterada. Os constantes avanços em pesquisas empregando cristais semicondutores nos exames cintilográficos, bem como a necessidade do surgimento de novos sistemas detectores, compactos, com maior poder de resolução e alta sensibilidade conjugados a crescente preocupação mundial com a minimização das doses de radiação ionizante utilizadas nos exames diagnósticos e terapias, impulsionou o desenvolvimento de novos sistemas detectores. Recentemente, duas Grandes Empresas lançaram comercialmente novos sistemas de detecção para aquisições tomográficas em medicina nuclear, utilizando detectores do estado sólido, mais especificamente cristais de telureto de cádmio e zinco (CZT). Algumas vantagens desse tipo de detector são a melhora sensível da relação sinal/ruído, o aumento da resolução espectral e espacial, o que em suma, resultam numa maior nitidez das imagens obtidas. O emprego desses detectores abre novas perspectivas para os protocolos de imagem. Entretanto, devido a inúmeros fatores, os equipamentos ditos CZT estão focados na área cardiológica, e devido a características próprias requerem a reformulação dos protocolos de aquisição de imagem além daqueles destinados ao ... / Abstract: Nuclear medicine is a medical specialty that deals with imaging techniques to observe the physiological status of the tissues or organs noninvasively, by dialing molecules participating in this process, with radioactive isotopes, thus giving the so-called radionuclides. The SPECT is a device that uses planar images, taken from different angles around the object of interest, and, through computer algorithms, obtains a tomographic image of those projections. Its origin refers for nearly fifty years ago, with the creation of the Chamber Anger (Anger Hall, 1964). Throughout this time, although there has been some evolution, the structure of these gamma cameras was virtually unchanged. The constant advances in research employing semiconductor crystals in scintigraphic examinations, as well as the need for the creation of new detectors systems, compacts, higher resolution and high sensitivity; combined with growing worldwide concern with minimization of doses of ionizing radiation used in diagnostic tests and therapies, spurred the development of new detector systems. Recently, two large companies launched commercially new detection systems for nuclear medicine tomographic acquisitions, using solid-state detectors, specifically crystals of zinc and cadmium telluride (CZT). Some advantages of this type of detector are sensitive improvement of signal / noise ratio, increased spectral and spatial resolution, which in short, resulting in greater clarity of the images obtained. The use of these detectors opens news perspectives for imaging protocols. However, due to numerous factors, equipment said CZT are focused on cardiology area, and due to the inherent characteristics, require reformulation of image acquisition protocols beyond those intended for Quality Control / Mestre
20

Mapas do espaço recíproco de camadas epitaxiais de CdTe / Reciprocal space maps of CdTe epitaxial layers

Silva Junior, Gilberto Rodrigues da 20 July 2017 (has links)
Submitted by Marco Antônio de Ramos Chagas (mchagas@ufv.br) on 2018-03-15T13:07:11Z No. of bitstreams: 1 texto completo.pdf: 2639032 bytes, checksum: 153bde729e19c083a2c7e0cb47ba91f2 (MD5) / Made available in DSpace on 2018-03-15T13:07:11Z (GMT). No. of bitstreams: 1 texto completo.pdf: 2639032 bytes, checksum: 153bde729e19c083a2c7e0cb47ba91f2 (MD5) Previous issue date: 2017-07-20 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Neste trabalho, foi realizada a caracterização estrutural de camadas de CdTe crescidas sobre substrato de Si(111). Mais precisamente, foi analisada a influência da temperatura de crescimento na qualidade estrutural das camadas. As amostras foram obtidas pela técnica de epitaxia por feixe molecular (MBE) e caracterizadas por difração de raios-X de alta resolução. As características estruturais foram analisadas através de medidas 2θ - ω e rocking curve , além da construção de mapas do espaço recíproco em torno das reflexões de Bragg simétricas (111) e assimétricas (224). Todos os resultados obtidos através das medidas de difração de raios-X indicaram que o aumento da temperatura de crescimento favoreceu o crescimento de uma camada epitaxial com menor densidade de defeitos. Além disso, as construções dos mapas do espaço recíproco possibilitaram uma análise mais detalhada da estrutura cristalina da camada epitaxial. Os mapas simétricos indicaram que abaixo de 300°C a camada cresceu com características de um policristal com textura, além de evidenciar a existência de uma inclinação cristalográfica entre as redes cristalinas da camada e do substrato. Os mapas assimétricos possibilitaram obter o estado de relaxação da camada, cujas características se mostraram condizentes com camadas epitaxiais totalmente relaxadas. / In this work, the structural characterization of CdTe layers grown on (111) Si substrate was performed. More precisely, the influence of the growth temperature on the structural quality of the layers was analyzed. The samples were obtained by molecular beam epitaxy technique (MBE) and characterized by high resolution X-ray diffraction. The structural characteristics were analyzed through 2θ-ω measurements and rocking curve, as well as the construction of reciprocal space maps around symmetric (111) and asymmetric (224) Bragg reflections. All results obtained by the X-ray diffraction measurements indicated that the increase in the growth temperature favored the growth of an epitaxial layer with lower defect density. In addition, the construction of the reciprocal space maps allowed for a more detailed analysis of the crystalline structure of the epitaxial layer. The symmetrical maps indicated that below 300 °C the layer grew with the characteristics of a textured polycrystalline, as well as evidencing the existence of a crystallographic tilt between the crystal lattices of the layer and the substrate. The asymmetric maps allowed to obtain the state of relaxation of the layer, whose characteristics were shown compatible with completely relaxed epitaxial layers.

Page generated in 0.0452 seconds