Spelling suggestions: "subject:"alternate"" "subject:"alternately""
1 |
Tomografia por biosusceptometria de corrente alternadaFonseca Filho, Paulo Roberto da [UNESP] 03 February 2014 (has links) (PDF)
Made available in DSpace on 2015-05-14T16:53:14Z (GMT). No. of bitstreams: 0
Previous issue date: 2014-02-03Bitstream added on 2015-05-14T16:59:09Z : No. of bitstreams: 1
000822024_20160203.pdf: 74282 bytes, checksum: 81fcaba4dabd99298046b62189ca92be (MD5) Bitstreams deleted on 2016-02-03T15:35:12Z: 000822024_20160203.pdf,. Added 1 bitstream(s) on 2016-02-03T15:35:53Z : No. of bitstreams: 1
000822024.pdf: 798249 bytes, checksum: cf24aa6eedaa8b219d13e0e5cf032c2e (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / A busca por novos métodos de imagens, principalmente os livres de radiação ionizante, são importantes tanto pelas instrumentações, quanto para as finalidades. A Biosusceptometria de |Corrente Alternada (BAC) possui versatilidade, sensibilidade, baixo custo e têm sido amplamente utilizada na aquisição de imagens para estudos nas áreas de gastrenterologia, fisiologia, farmacologia e farmácia. O objetivo deste trabalho foi caracterizar sistemas de BAC na produção de imagens tomográficas de objetos simuladores, propondo a viabilidade da técnica de tBAC - tomografia por biosusceptometria de Corrente Alternada. Para tanto, os gradiômetros de dois sistemas BAC com 13 e 37 canais com compensação de campo de excitação foram avaliados quanto à sua sensibilidade e resolução para produzir imagens de simuladores de barras e cilíndri-cos. Foi possível reconstruir imagens de todos os objetos com boa correlação entre a imagem e as caracte-rísticas físicas dos objetos (forma e concentração de traçador magnético). As melhores imagens foram pro-duzidas quando foi utilizada aquisição multicanal no sistema de BAC com 37 sensores utilizando compen-sação de campo, os quais possuem menores diâmetros. Dessa forma verificou-se que os sistemas BAC podem ser empregados com sucesso para produzir imagens tomográficas de objetos com pequena quanti-dade de traçador magnético, o que viabiliza sua aplicação futura em pequenos animais, farmacotecnia ou ainda ensaios não destrutivos / The development of new imaging methods, especially those that are free of ionizing radiation, constitute a very important topic because for both instrumentation development and its applications. The Alternating Current Biosusceptometry (ACB) has versatility, sensibility and low cost and has been widely used on image acquisition on gastroenterology, physiology, pharmaceutics and pharmacology researches. The aim of this project was to characterize ACB systems to produce tomographic images of simulating objects ver-ifying the technical viability of the AC Biosusceptometry Tomography (ACBT). The capability of ACB gradiometers of 13 and 37 channel systems with compensation field to reconstruct images of bars and cy-lindrical phantoms were evaluated, especially sensibility and resolution. It was possible to reconstruct im-ages from all objects with good correlation between the image and the phantom (geometry and magnetic tracer concentration). Better results were observed while using multichannel acquisition on 37-channel sys-tem with active excitation magnetic field. Therefore we verified that ACB systems can be successfully used on tomographic imaging of objects with small quantities of magnetic tracer, which is viable to future ap-plication on small animal physiology, pharmaceutics or non-destructive evaluation research
|
2 |
Tomografia por biosusceptometria de corrente alternada /Fonseca Filho, Paulo Roberto da. January 2014 (has links)
Orientador: José Ricardo de Arruda Miranda / Banca: Oswaldo Baffa Filho / Banca: Roberto Morato Fernandez / Banca: Fernando Gomes Romeiro / Banca: Valmir Fadel / Resumo: A busca por novos métodos de imagens, principalmente os livres de radiação ionizante, são importantes tanto pelas instrumentações, quanto para as finalidades. A Biosusceptometria de |Corrente Alternada (BAC) possui versatilidade, sensibilidade, baixo custo e têm sido amplamente utilizada na aquisição de imagens para estudos nas áreas de gastrenterologia, fisiologia, farmacologia e farmácia. O objetivo deste trabalho foi caracterizar sistemas de BAC na produção de imagens tomográficas de objetos simuladores, propondo a viabilidade da técnica de tBAC - tomografia por biosusceptometria de Corrente Alternada. Para tanto, os gradiômetros de dois sistemas BAC com 13 e 37 canais com compensação de campo de excitação foram avaliados quanto à sua sensibilidade e resolução para produzir imagens de simuladores de barras e cilíndri-cos. Foi possível reconstruir imagens de todos os objetos com boa correlação entre a imagem e as caracte-rísticas físicas dos objetos (forma e concentração de traçador magnético). As melhores imagens foram pro-duzidas quando foi utilizada aquisição multicanal no sistema de BAC com 37 sensores utilizando compen-sação de campo, os quais possuem menores diâmetros. Dessa forma verificou-se que os sistemas BAC podem ser empregados com sucesso para produzir imagens tomográficas de objetos com pequena quanti-dade de traçador magnético, o que viabiliza sua aplicação futura em pequenos animais, farmacotecnia ou ainda ensaios não destrutivos / Abstract: The development of new imaging methods, especially those that are free of ionizing radiation, constitute a very important topic because for both instrumentation development and its applications. The Alternating Current Biosusceptometry (ACB) has versatility, sensibility and low cost and has been widely used on image acquisition on gastroenterology, physiology, pharmaceutics and pharmacology researches. The aim of this project was to characterize ACB systems to produce tomographic images of simulating objects ver-ifying the technical viability of the AC Biosusceptometry Tomography (ACBT). The capability of ACB gradiometers of 13 and 37 channel systems with compensation field to reconstruct images of bars and cy-lindrical phantoms were evaluated, especially sensibility and resolution. It was possible to reconstruct im-ages from all objects with good correlation between the image and the phantom (geometry and magnetic tracer concentration). Better results were observed while using multichannel acquisition on 37-channel sys-tem with active excitation magnetic field. Therefore we verified that ACB systems can be successfully used on tomographic imaging of objects with small quantities of magnetic tracer, which is viable to future ap-plication on small animal physiology, pharmaceutics or non-destructive evaluation research / Doutor
|
3 |
Aplicação do sistema de biosusceptometria AC para monitoramento de nanopartículas magnéticas na circulação sanguínea /Próspero, André Gonçalves. January 2015 (has links)
Orientador: José Ricardo de Arruda Miranda / Coorientador: Patricia Fidelis de Oliveira Gregolini / Banca: Joel Mesa / Banca: Andris Figueiroa Bakuzis / Resumo: As técnicas biomagnéticas possibilitam o estudo de diversos parâmetros fisiológicos através da detecção de campos magnéticos gerados por correntes biológicas ou por marcadores/traçadores magnéticos. Uma das técnicas utilizadas dentro desta vertente é a Biosusceptometria de Corrente Alternada (BAC). A técnica utiliza um sistema gradiométrico de bobinas para monitorar posição e concentração de materiais magnéticos em sistemas biológicos. A partir do monitoramento realizado pelo sistema, é possível obter dados relacionados com as propriedades biológicas locais e estabelecer parâmetros mecânico-fisiológicos, principalmente do trato gastrintestinal, como esvaziamento e atividade de contração gástrica. A proposta deste trabalho é inédita e consiste na aplicação do sistema BAC, associado à nanopartículas magnéticas utilizadas como traçadores, a fim de, futuramente, disponibilizar uma nova ferramenta para estudos de caracterização pré-clínica de nanopartículas magnéticas. Foram realizados experimentos com ratos para a quantificação do tempo de meia vida das nanopartículas magnéticas em intervalos de tempo pré definidos, além do tempo de chegada das partículas no coração dos animais, bem como sua biodistribuição. Como testes adicionais, foram realizadas quantificações de alterações em parâmetros cardiovasculares sobre a administração endovenosa das nanopartículas magnéticas, já que esses parâmetros cardiovasculares influenciam diretamente no tempo de meia vida e biodistribuição do material. O sistema demonstrou bom desempenho em todos os testes aplicados, apresentando excelente reprodutibilidade, sensibilidade e resolução temporal. Os resultados sugerem a utilização da BAC como método de avaliação de parâmetros de caraterização pré-clínica de nanopartículas magnéticas em organismos vivos, em avaliações de biodistribuição e tempo de meia vida das nanopartículas... / Abstract: In the Biomagnetic research field, several methods have reported to study physiological parameters through the detection of magnetic fields generated by biological electrical currents or magnetic marker/tracers. Among such techniques, the Alternating Current Biosusceptometry (AC Biosusceptometry or ACB) system has been developed and refined with the main purpose of detecting and monitoring magnetic materials in biological systems (mainly in the gastrointestinal tract so far). With a pair of gradiometric pickup coils, the ACB system is able to obtain data related to local biological properties and also to study mechanical and physiological parameters, such as gastric emptying and contraction activity. This work presents an unprecedented study that applies the ACB system, associated to magnetic nanoparticles, as a new tool for preclinical characterization of magnetic nanoparticles. In vivo Experiments were performed in rat models to quantify the magnetic nanoparticles half-life in predefined time intervals, the particles arrival time in the animals heart and also the nanoparticles biodistribution. As an additional test, cardiovascular parameters were acquired during the particle intravenous administration, since these parameters directly influence the material half-life and biodistribution. The system presented good performance in all tests, with excellent reproducibility, sensitivity and temporal resolution. Also, these results suggest the ACB using as valuable evaluation method for magnetic nanoparticles preclinical characterization, in parameters as biodistribution and half-life in the bloodstream, since transient changes in mean arterial pressure and heart rate were found due to the magnetic nanoparticles intravenous administration. This work includes the development and characterization of a new low cost physics instrumentation, to subsidize circulatory system research, in small animals, and new nanostructured materials applications ... / Mestre
|
4 |
Aplicação do sistema de biosusceptometria AC para monitoramento de nanopartículas magnéticas na circulação sanguíneaPróspero, André Gonçalves [UNESP] 26 February 2015 (has links) (PDF)
Made available in DSpace on 2015-12-10T14:22:23Z (GMT). No. of bitstreams: 0
Previous issue date: 2015-02-26. Added 1 bitstream(s) on 2015-12-10T14:28:28Z : No. of bitstreams: 1
000848395.pdf: 2504523 bytes, checksum: 3e311603d829f6daa3c4f95a93b6adbd (MD5) / As técnicas biomagnéticas possibilitam o estudo de diversos parâmetros fisiológicos através da detecção de campos magnéticos gerados por correntes biológicas ou por marcadores/traçadores magnéticos. Uma das técnicas utilizadas dentro desta vertente é a Biosusceptometria de Corrente Alternada (BAC). A técnica utiliza um sistema gradiométrico de bobinas para monitorar posição e concentração de materiais magnéticos em sistemas biológicos. A partir do monitoramento realizado pelo sistema, é possível obter dados relacionados com as propriedades biológicas locais e estabelecer parâmetros mecânico-fisiológicos, principalmente do trato gastrintestinal, como esvaziamento e atividade de contração gástrica. A proposta deste trabalho é inédita e consiste na aplicação do sistema BAC, associado à nanopartículas magnéticas utilizadas como traçadores, a fim de, futuramente, disponibilizar uma nova ferramenta para estudos de caracterização pré-clínica de nanopartículas magnéticas. Foram realizados experimentos com ratos para a quantificação do tempo de meia vida das nanopartículas magnéticas em intervalos de tempo pré definidos, além do tempo de chegada das partículas no coração dos animais, bem como sua biodistribuição. Como testes adicionais, foram realizadas quantificações de alterações em parâmetros cardiovasculares sobre a administração endovenosa das nanopartículas magnéticas, já que esses parâmetros cardiovasculares influenciam diretamente no tempo de meia vida e biodistribuição do material. O sistema demonstrou bom desempenho em todos os testes aplicados, apresentando excelente reprodutibilidade, sensibilidade e resolução temporal. Os resultados sugerem a utilização da BAC como método de avaliação de parâmetros de caraterização pré-clínica de nanopartículas magnéticas em organismos vivos, em avaliações de biodistribuição e tempo de meia vida das nanopartículas... / In the Biomagnetic research field, several methods have reported to study physiological parameters through the detection of magnetic fields generated by biological electrical currents or magnetic marker/tracers. Among such techniques, the Alternating Current Biosusceptometry (AC Biosusceptometry or ACB) system has been developed and refined with the main purpose of detecting and monitoring magnetic materials in biological systems (mainly in the gastrointestinal tract so far). With a pair of gradiometric pickup coils, the ACB system is able to obtain data related to local biological properties and also to study mechanical and physiological parameters, such as gastric emptying and contraction activity. This work presents an unprecedented study that applies the ACB system, associated to magnetic nanoparticles, as a new tool for preclinical characterization of magnetic nanoparticles. In vivo Experiments were performed in rat models to quantify the magnetic nanoparticles half-life in predefined time intervals, the particles arrival time in the animals heart and also the nanoparticles biodistribution. As an additional test, cardiovascular parameters were acquired during the particle intravenous administration, since these parameters directly influence the material half-life and biodistribution. The system presented good performance in all tests, with excellent reproducibility, sensitivity and temporal resolution. Also, these results suggest the ACB using as valuable evaluation method for magnetic nanoparticles preclinical characterization, in parameters as biodistribution and half-life in the bloodstream, since transient changes in mean arterial pressure and heart rate were found due to the magnetic nanoparticles intravenous administration. This work includes the development and characterization of a new low cost physics instrumentation, to subsidize circulatory system research, in small animals, and new nanostructured materials applications ...
|
5 |
Avaliação da atividade eletromecânica uterina em ratas por biosusceptometria AC e eletromiografiaSimões, Luís Gustavo de Oliveira [UNESP] 26 February 2015 (has links) (PDF)
Made available in DSpace on 2015-12-10T14:22:29Z (GMT). No. of bitstreams: 0
Previous issue date: 2015-02-26. Added 1 bitstream(s) on 2015-12-10T14:28:35Z : No. of bitstreams: 1
000850389.pdf: 1079649 bytes, checksum: d2cf5a0a2ac5d8a9a0681e25b2296376 (MD5) / O útero é um órgão constituído de musculatura lisa, que se contrai periodicamente devido às células de marca-passo localizadas no miométrio. As técnicas in vitro são as mais utilizadas para estudar as mudanças no comportamento uterino, porém não promovem uma análise em ambiente fisiológico real. Este trabalho teve como principal objetivo aplicar a técnica de Biosusceptometria de Corrente Alternada (BAC) e Eletromiografia (EMG) para estudos dos padrões elétrico e mecânico de contração uterina em ratas. O sistema BAC registra o evento mecânico através do deslocamento do material magnético inserido no meio biológico, enquanto o EMG registra a atividade elétrica da fibra muscular ativa através de estímulos na própria musculatura. Neste estudo, todas as medidas foram realizadas com ambas as técnicas atuando simultaneamente. Foram utilizadas 20 ratas Wistar não prenhes, com peso entre 200 e 300 gramas, com implantes de eletrodo e marcador magnético (MnFe2O4) na serosa do útero. Foi realizada uma análise das contrações em cada fase do ciclo estral e, posteriormente, foram realizadas análises utilizando drogas que alterassem o perfil normal de contração para confirmar a eficiência do método: a ocitocina e o butilbrometo de escopolamina. Os resultados mostraram que o útero, em seu estado normal, apresentou dois tipos nítidos de contração, de alta intensidade e baixa frequência (13,62 ± 1,503 mHz para contração mecânica e 13,17 ± 1,201 mHz para contração elétrica), e de baixa intensidade e alta frequência (62,52 ± 4,499 mHz para contração mecânica e 65,08 ± 6,341 mHz para contração elétrica). Em termos de frequência e morfologia, não foram constatadas diferenças entre as fases do ciclo estral. Em ambas as administrações de fármacos não houve uma modificação relevante quanto à freqüência. A amplitude no caso da ocitocina não apresentou diferenças significativas em nenhum dos... / The Uterus is a smooth muscle organ that contracts periodically due to the peacemaker cells located on myometrium. In vitro techniques are the most used to study the change in the uterine behavior, still they lack on promoting a real physiological analyses. This main purpose of this study was to apply the Alternating Current Biosusceptometry (AC Biosusceptometry or ACB) and the Electromyography (EMG) systems to evaluate uterine electrical and mechanical patterns in rats. The ACB technique registers the mechanical event by acquiring the displacement of the magnetic material inserted in the biological system, while the EMG register the electrical activity of the active muscular fiber by simulating the muscle itself. Both electrical and mechanical studies were conducted simultaneously. For this study, 20 non pregnant Wistar rats weighting between 200 and 300 g were submitted to the electrode and magnetic marker (MnFe2O4) implant surgery on the uterus serous. Thus, the contraction pattern during the entire estrous cycle was acquired, followed by the same study under influence of specific drugs (oxytocin and scopolamine butylbromide), which had the function to modify the contraction profile to confirm the method efficiency. Results showed two distinct contraction patterns for the uterus on its normal condition. The ACB and EMG systems acquired a high intensity and low frequency (13,62 ± 1,503 mHz to mechanic contraction and 13,17 ± 1,201 mHz to electrical contraction) pattern along with a low intensity and high frequency (62,52 ± 4,499 mHz to mechanical contraction and 65,08 ± 6,341 mHz to electrical one). Although regarding frequency and morphology, no differences were observed among the estrous cycle phases. Neither the oxitocyn nor the butylbromide showed relevant interference on the frequency pattern. For the amplitude, despite the oxytocin have not presented significant differences in neither the events (electrical and mechanical), ...
|
6 |
Tomografia por biosusceptometria de corrente alternada (TBAC): novas Instrumentações e caracterizaçõesMatos, Ronaldo Vitor Reis [UNESP] 27 February 2015 (has links) (PDF)
Made available in DSpace on 2016-09-27T13:39:56Z (GMT). No. of bitstreams: 0
Previous issue date: 2015-02-27. Added 1 bitstream(s) on 2016-09-27T13:45:04Z : No. of bitstreams: 1
000868423.pdf: 1580754 bytes, checksum: 2d3557a2b3a9cb215c4cdfdb57a79da8 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Nos últimos anos tem-se buscado o desenvolvimento de técnicas que sejam livres de radiação ionizante, como as técnicas biomagnéticas. Destas, destaca-se a biosusceptometria de corrente alternada (BAC), que é uma técnica bastante simples, baixo custo e versátil que possui grande aplicação em pesquisas relacionadas ao trato gastrintestinal humano e recentemente foi aprimorada para que pudesse gerar imagens de marcadores ferromagnéticos tanto in vitro quanto in vivo, a partir disso foi proposta uma nova instrumentação para a realização de imagens tomográficas denominado de Tomografia por Biosusceptometria de Corrente Alternada (TBAC). Este projeto propõe o desenvolvimento de novas instrumentações e caracterizações computacionais de recursos que possibilitem a aplicação da BAC para produzir imagens tomográficas de fantomas in vitro. Para tanto, foi construído novos sistemas de aquisição de imagens com amostras e sensores girantes e aplicação de algoritmo de reconstrução (método de retroprojeção filtrada) para obter imagens tomográficas de diferentes fantomas por biosusceptometria de corrente alternada. Para os sistemas planares houve avanços na sensibilidade ou intensidade de sinal de 50 % e em resolução espacial passou de 7,4 cm para 5,7 cm, já que, foi alterado o raio de detecção e excitação em relação a outro sistema já utilizado anteriormente. Quando comparamos os sistemas planares ao novo sistema circular o ganho em relação a resolução temporal foi significante, passando de 3 horas para 2 minutos o que nos proporcionará futuras medidas in vivo, apensar deste ganho devido ao modo de aquisição dos sinais outros problemas foram encontrados como novos métodos de processamento dos sinais, assim como novos algoritmos de reconstrução / In recent years researchers have tried to develop techniques that are free of ionizing radiation, such as biomagnetic techniques. Of these, there is the AC biosusceptometria (BAC), which is a very simple technique, low cost and versatile which has wide application in research related to the human gastrointestinal tract and recently has been enhanced so that it could generate ferromagnetic markers pictures both in vitro and in vivo, as it was proposed a new instrumentation for the acquisition of tomographic images referred to as Alternating Current Biosusceptometria Tomography (ACBT). This project proposes the development of new instrumentation and computational resources characterizations that allow the application of BAC to produce tomographic images of phantoms in vitro. To that end, we built new image acquisition systems with samples and rotating sensors and reconstruction algorithm application (filtered back projection method) to obtain tomographic images of different phantoms by AC biosusceptometria. For planar systems there have been advances in sensitivity or 50% signal strength and spatial resolution increased from 7.4 cm to 5.7 cm, since the radius of detection and excitation has been changed from the other system previously used . Comparing the planar systems with new circular system the temporal resolution gain was significant, from 3 hours to 2 minutes which will give us future in vivo measurements, to join this gain due to the acquisition mode of the signals other problems were found as new signal processing methods as well as new reconstruction algorithms
|
7 |
Avaliação da atividade eletromecânica uterina em ratas por biosusceptometria AC e eletromiografia /Simões, Luís Gustavo de Oliveira. January 2015 (has links)
Orientador: José Ricardo de Arruda Miranda / Banca: Ricardo Brandt de Oliveira / Banca: Roberto Morato Fernandez / Resumo: O útero é um órgão constituído de musculatura lisa, que se contrai periodicamente devido às células de marca-passo localizadas no miométrio. As técnicas in vitro são as mais utilizadas para estudar as mudanças no comportamento uterino, porém não promovem uma análise em ambiente fisiológico real. Este trabalho teve como principal objetivo aplicar a técnica de Biosusceptometria de Corrente Alternada (BAC) e Eletromiografia (EMG) para estudos dos padrões elétrico e mecânico de contração uterina em ratas. O sistema BAC registra o evento mecânico através do deslocamento do material magnético inserido no meio biológico, enquanto o EMG registra a atividade elétrica da fibra muscular ativa através de estímulos na própria musculatura. Neste estudo, todas as medidas foram realizadas com ambas as técnicas atuando simultaneamente. Foram utilizadas 20 ratas Wistar não prenhes, com peso entre 200 e 300 gramas, com implantes de eletrodo e marcador magnético (MnFe2O4) na serosa do útero. Foi realizada uma análise das contrações em cada fase do ciclo estral e, posteriormente, foram realizadas análises utilizando drogas que alterassem o perfil normal de contração para confirmar a eficiência do método: a ocitocina e o butilbrometo de escopolamina. Os resultados mostraram que o útero, em seu estado normal, apresentou dois tipos nítidos de contração, de alta intensidade e baixa frequência (13,62 ± 1,503 mHz para contração mecânica e 13,17 ± 1,201 mHz para contração elétrica), e de baixa intensidade e alta frequência (62,52 ± 4,499 mHz para contração mecânica e 65,08 ± 6,341 mHz para contração elétrica). Em termos de frequência e morfologia, não foram constatadas diferenças entre as fases do ciclo estral. Em ambas as administrações de fármacos não houve uma modificação relevante quanto à freqüência. A amplitude no caso da ocitocina não apresentou diferenças significativas em nenhum dos... / Abstract: The Uterus is a smooth muscle organ that contracts periodically due to the peacemaker cells located on myometrium. In vitro techniques are the most used to study the change in the uterine behavior, still they lack on promoting a real physiological analyses. This main purpose of this study was to apply the Alternating Current Biosusceptometry (AC Biosusceptometry or ACB) and the Electromyography (EMG) systems to evaluate uterine electrical and mechanical patterns in rats. The ACB technique registers the mechanical event by acquiring the displacement of the magnetic material inserted in the biological system, while the EMG register the electrical activity of the active muscular fiber by simulating the muscle itself. Both electrical and mechanical studies were conducted simultaneously. For this study, 20 non pregnant Wistar rats weighting between 200 and 300 g were submitted to the electrode and magnetic marker (MnFe2O4) implant surgery on the uterus serous. Thus, the contraction pattern during the entire estrous cycle was acquired, followed by the same study under influence of specific drugs (oxytocin and scopolamine butylbromide), which had the function to modify the contraction profile to confirm the method efficiency. Results showed two distinct contraction patterns for the uterus on its normal condition. The ACB and EMG systems acquired a high intensity and low frequency (13,62 ± 1,503 mHz to mechanic contraction and 13,17 ± 1,201 mHz to electrical contraction) pattern along with a low intensity and high frequency (62,52 ± 4,499 mHz to mechanical contraction and 65,08 ± 6,341 mHz to electrical one). Although regarding frequency and morphology, no differences were observed among the estrous cycle phases. Neither the oxitocyn nor the butylbromide showed relevant interference on the frequency pattern. For the amplitude, despite the oxytocin have not presented significant differences in neither the events (electrical and mechanical), ... / Mestre
|
8 |
Tomografia por biosusceptometria de corrente alternada (TBAC) : novas Instrumentações e caracterizaçõesMatos, Ronaldo Vitor Reis. January 2015 (has links)
Orientador: José Ricardo de Arruda Miranda / Banca: Luciana Aparecida Corá / Banca: Roberto Morato Fernandez / Resumo: Nos últimos anos tem-se buscado o desenvolvimento de técnicas que sejam livres de radiação ionizante, como as técnicas biomagnéticas. Destas, destaca-se a biosusceptometria de corrente alternada (BAC), que é uma técnica bastante simples, baixo custo e versátil que possui grande aplicação em pesquisas relacionadas ao trato gastrintestinal humano e recentemente foi aprimorada para que pudesse gerar imagens de marcadores ferromagnéticos tanto in vitro quanto in vivo, a partir disso foi proposta uma nova instrumentação para a realização de imagens tomográficas denominado de Tomografia por Biosusceptometria de Corrente Alternada (TBAC). Este projeto propõe o desenvolvimento de novas instrumentações e caracterizações computacionais de recursos que possibilitem a aplicação da BAC para produzir imagens tomográficas de fantomas in vitro. Para tanto, foi construído novos sistemas de aquisição de imagens com amostras e sensores girantes e aplicação de algoritmo de reconstrução (método de retroprojeção filtrada) para obter imagens tomográficas de diferentes fantomas por biosusceptometria de corrente alternada. Para os sistemas planares houve avanços na sensibilidade ou intensidade de sinal de 50 % e em resolução espacial passou de 7,4 cm para 5,7 cm, já que, foi alterado o raio de detecção e excitação em relação a outro sistema já utilizado anteriormente. Quando comparamos os sistemas planares ao novo sistema circular o ganho em relação a resolução temporal foi significante, passando de 3 horas para 2 minutos o que nos proporcionará futuras medidas in vivo, apensar deste ganho devido ao modo de aquisição dos sinais outros problemas foram encontrados como novos métodos de processamento dos sinais, assim como novos algoritmos de reconstrução / Abstract: In recent years researchers have tried to develop techniques that are free of ionizing radiation, such as biomagnetic techniques. Of these, there is the AC biosusceptometria (BAC), which is a very simple technique, low cost and versatile which has wide application in research related to the human gastrointestinal tract and recently has been enhanced so that it could generate ferromagnetic markers pictures both in vitro and in vivo, as it was proposed a new instrumentation for the acquisition of tomographic images referred to as Alternating Current Biosusceptometria Tomography (ACBT). This project proposes the development of new instrumentation and computational resources characterizations that allow the application of BAC to produce tomographic images of phantoms in vitro. To that end, we built new image acquisition systems with samples and rotating sensors and reconstruction algorithm application (filtered back projection method) to obtain tomographic images of different phantoms by AC biosusceptometria. For planar systems there have been advances in sensitivity or 50% signal strength and spatial resolution increased from 7.4 cm to 5.7 cm, since the radius of detection and excitation has been changed from the other system previously used . Comparing the planar systems with new circular system the temporal resolution gain was significant, from 3 hours to 2 minutes which will give us future in vivo measurements, to join this gain due to the acquisition mode of the signals other problems were found as new signal processing methods as well as new reconstruction algorithms / Mestre
|
9 |
Synthesis and structure-properties relationship of alternated π-conjugated copolymers / Synthèse et relation structure-propriétés de copolymères alternés π-conjuguésOriou, Jules 10 December 2013 (has links)
Tout au long du siècle dernier, l’électronique s’est révélé être un progrès technologique majeur, et ses applications sont tellement nombreuses qu’elles ont envahi notre vie de tous les jours. De par leurs propriétés bien spécifiques, les semi-conducteurs organiques représentent une remarquable alternative aux matériaux inorganiques utilisés actuellement. Cependant, leurs propriétés électriques peuvent être limitées, et l’efficacité des dispositifs composés de tels matériaux ne permet pas encore de rivaliser avec ceux basés sur des matériaux inorganiques. Dans ce contexte, ce travail de thèse a pour objectif de synthétiser et caractériser de nouveaux polymères conjugués et d’étudier leurs propriétés, dans le but d’ajouter de nouveaux matériaux au déjà riche catalogue de polymères semi-conducteurs disponibles, ainsi que de permettre une meilleure compréhension de la relation structure-propriétés dans les systèmes conjugués. Des copolymères alternés composés de motifs carbazole, benzothiadiazole ou encore squaraine ont été synthétisés et caractérisés. De plus, des polymérisations originales et sans catalyseurs métalliques ont été développées. / Within the last century, electronics have become a major technological breakthrough and the resulting applications are so numerous that it has invaded our every-day life. Due to their properties, organic semiconductors have attracted much attention and represent a great alternative to the nowadays used inorganic materials. However, their electrical properties can be limited, and the efficiencies of the resulting devices are still not completely competitive against the inorganic-based ones. In this context, this PhD goal was to synthesize novel conjugated polymers (CPs) and investigate their properties, in order to add novel materials to the already wide catalogue of semiconducting polymers and allow a better comprehension of the structure-properties relationship in conjugated systems. Alternated copolymers based on carbazole, benzothiadiazole, or squaraine were synthesized and characterized. Furthermore, original and metal catalyst-free polymerizations were successfully developed.
|
10 |
Estudo da motilidade gástrica em ratas prunhes diabéticas /Matos, Juliana Fernandes de. January 2015 (has links)
Orientador: José Ricardo de Arruda Miranda / Banca: Madileine Francely Américo / Banca: Débora Cristina Damasceno / Resumo: Trata-se de um estudo qualitativo que teve como objetivo compreender o desenvolvimento de habilidades comunicativas no aluno de graduação em Enfermagem e a atuação do professor neste processo de ensino aprendizagem considerando diferentes tipos de organização curricular. O referencial teórico utilizado foi pautado nos estudos de Braga e Silva para a compreensão da competência em comunicação no aprendizado e ensino da Enfermagem, e a Análise de Conteúdo, segundo Bardin, como referencial metodológico. O estudo foi realizado em duas instituições públicas de ensino superior, situadas no interior do estado de São Paulo, que empregam metodologias de ensino diferenciadas; o Curso de Graduação em Enfermagem da Faculdade de Medicina de Botucatu, UNESP, localizado no município de Botucatu e o Curso de Graduação em Enfermagem da Faculdade de Medicina de Marília, FAMEMA, localizado no município de Marília. A coleta de dados foi realizada a partir da perspectiva dos docentes e discentes do 2º e 4ª anos de Enfermagem, com o apoio de questões norteadoras por meio de entrevistas gravadas e formulários de auto-preenchimento, respectivamente. As questões éticas foram consideradas de acordo com a resolução 466/12 do Conselho Nacional de Saúde (CNS) e da Comissão Nacional de ética em Pesquisa (CONEP), obtendo parecer favorável da Faculdade de Medicina de Botucatu, UNESP, com número CAAE: 18459013.0.3001.5413 e parecer nº 417.358. Em seguida, o projeto de pesquisa foi submetido ao parecer do CEP da Faculdade de Medicina de Marília, FAMEMA, obtendo aprovação com parecer nº 432.360. Nos resultados do estudo emergiram, na perspectiva dos docentes, as seguintes categorias temáticas sobre os fatores que influenciam no desenvolvimento de habilidades comunicativas nos graduandos de Enfermagem: a prática promove a aquisição de habilidades comunicativas; as características individuais dos estudantes; a utilização de... / Abstract: This is a qualitative study aiming at understanding the development of communication skills in undergraduate Nursing students and their teachers' action in such teaching-learning process by considering different types of curricular organizations. The theoretical framework used was based on the studies by Braga and Silva in order to understand communication competence in Nursing teaching and learning. Content analysis according to Bardin was used as a methodological framework. The study was performed in two public institutions of higher education located in inner São Paulo state which employ differentiated teaching methodologies: the Undergraduate Nursing Program of Botucatu Medical School, UNESP, located in the city of Botucatu, and the Undergraduate Nursing Program Marília Medical School, FAMEMA, located in the city of Marília. Data were collected from the perspective of professors and students of the 2nd and 4th years of the Nursing Program, based on guiding questions by means of taped interviews and selfadministered questionnaires, respectively. Ethical issues were considered according to Resolution 466/12 by the National Health Care Council (Conselho Nacional de Saúde - CNS) and the National Research Ethics Committee (Comissão Nacional de Ética em Pesquisa - CONEP), thus obtaining approval by the Botucatu Medical School, UNESP, according to CAAE number: 18459013.0.3001.5413 and Process Number 417.358. Next the research project was submitted to evaluation by the Research Ethics Committee of Marília Medical School, FAMEMA, and approved according to Process Number 432.360. The following thematic categories concerning the factors that influence the development of communication skills in undergraduate Nursing students emerged in the results of the study, according to the professors' perspective: the practice promotes the development of communication skills; the students' individual characteristics; the use of active ... / Mestre
|
Page generated in 0.0551 seconds