141 |
Improving Patient Satisfaction after Primary Total Knee Arthroplasty Using Nurse Practitioner-Driven Preoperative EducationWhite, Jennifer A. 27 April 2015 (has links)
No description available.
|
142 |
The Biomechanical Effects of Variability in Femoral and Tibial Component Rotational Alignment in TKA using a Simulated Oxford RigThompson, Julie Ann January 2009 (has links)
No description available.
|
143 |
Biomechanical Effects of Component Alignment Variability in Total Knee Arthroplasty: A Computer Simulation Study of an Oxford RigLemke, Sean Paul 25 June 2012 (has links)
No description available.
|
144 |
Assessing Limb Symmetry using the Clinically Accessible loadsol®Renner, Kristen Elizaberth 23 April 2019 (has links)
Decreased gait symmetry has been correlated with an increased fall risk, abnormal joint loading and decreased functional outcomes. Therefore, symmetry is focused on in the rehabilitation of many patient populations. Currently, load based symmetry is collected using expensive and immobile devices that are not clinically accessible, but there is a clinical need for an objective measure of loading symmetry during daily tasks like walking. Therefore, the purpose of this dissertation was to 1) assess the validity and reliability of the loadsol® to capture ground reaction force data, 2) use the loadsol® to determine the differences in symmetry between adults with a TKA and their healthy peers and 3) explore the potential of a commercially available biofeedback system to acutely improve gait symmetry in adults. The results of this work indicate that the loadsol® is a valid and reliable method of collecting loading measures during walking in both young and older adults. TKA patients who are 12-24 months post-TKA have lower symmetry in the weight acceptance peak force, propulsive peak force and impulse when compared to their healthy peers. Finally, a case study with four asymmetric adults demonstrated that a 10-minute biofeedback intervention with the loadsol® resulted in an acute improvement in symmetry. Future work is needed to determine the potential of this intervention to improve symmetry in patient populations and to determine whether the acute response is retained following the completion of the intervention. / Doctor of Philosophy / Symmetry during walking is a valuable attribute as asymmetry has been correlated with an increased fall risk and decreased mobility. Currently, load based symmetry is collected using expensive and immobile devices that are not clinically accessible. As a result, there is a critical need for a system that can objectively measure load and loading symmetry during rehabilitation and everyday tasks in a variety of settings. A new device has been developed (loadsol®) that could potentially fill this need. Before it can be used to assess and treat patients, the loadsol® needed to be assessed for accuracy and reliability in both older and younger adults and at various speeds. Then we needed to determine if the loadsol® can be used to look at the levels of symmetry in patients who have had a knee replacement compared to their healthy peers. Finally, we tested a visual biofeedback intervention with the loadsol® to see if this intervention was able to improve symmetry. We found that the loadsol® is accurate and reliable. Patients with a knee replacement were less symmetric than their age matched peers. Finally, in a small study, the visual biofeedback intervention improved symmetry during walking in a group of people with less than 90% symmetry. Future work is needed to explore the potential of this biofeedback intervention to improve symmetry in various patient populations and to determine the extent to which patients are able to retain these improvements.
|
145 |
Simulated Automobile and Rotary-Wing Aircraft Impacts: Dynamic Neck Response after Surgical Treatment for Cervical SpondylosisWhite, Nicholas Alan 02 January 2014 (has links)
Degeneration of the cervical spine is part of the normal aging process, usually occurring without clinical symptoms. Symptomatic degeneration most often occurs in the lower cervical spine, presenting as axial neck pain, radiculopathy, myelopathy, or any combination of the three. When conservative treatment does not adequately manage these symptoms, surgical intervention may be required. The longstanding surgical treatment for cervical degeneration is arthrodesis achieved through anterior cervical discectomy and fusion (ACDF). A relatively newer treatment is arthroplasty with a cervical total disc replacement (CTDR), a motion-sparing procedure designed to maintain adjacent-level loading. While literature exists comparing the effects of cervical arthrodesis and cervical arthroplasty on neck kinematics and loading, the vast majority of these studies applied only quasi-static, non-injurious loading conditions. This dissertation research used a state-of-the-art, full body human finite element (FE) model to investigate the effects of these surgical procedures on neck response during simulated dynamic impacts.
A method was developed to measure cross-sectional forces and moments at each level of the neck in the FE model. Neck loading was captured during three automobile impact simulations: a frontal impact of a belted driver with airbag deployment, a frontal impact of a belted passenger without airbag deployment, and an unbelted side impact. The measured neck forces and moments were compared to existing injury threshold values and used to calculate injury criteria values. Four additional simulations of the frontal impact with the belted driver were conducted with neck modifications representative of either a fusion or arthroplasty of C5-6. While cross-sectional loading above and below the implants did not vary appreciably, key differences were noted in both the interbody and facet response. However, no neck injury thresholds were exceeded in any of the simulations.
With cervical radiculopathy diagnosed in 24,742 active-duty U.S. military personnel between 2000 and 2009, interest in cervical arthroplasty as treatment for symptomatic cervical degeneration in this population has increased. This motion-sparing procedure has the potential to expedite post-operative recovery time, allowing for these highly trained individuals to return to active-duty sooner than with a fusion. Due to the physically demanding nature of the military environment, it is important to ensure that this surgical procedure does not increase the likelihood of a neck injury.
An FE simulation environment was developed to investigate aviator head and neck response during a survivable, rotary-wing aircraft impact with the ground using both an anthropomorphic test device (ATD) and a human body model. The head and neck response of the ATD FE simulation was successfully validated against the results of a previously conducted experimental sled test. A more biofidelic head and neck response was produced with the human body model, including realistic changes in neck curvature. Additional simulations were conducted with the human body model to investigate the neck response after cervical arthroplasty of C5-6. While the adjacent-level, cross-sectional loading for the C5-6 segment was not appreciably altered by the CTDRs, the interbody range-of-motion was increased; subsequently altering both the interbody and cervical facet loading. Again, no neck injury thresholds were exceeded in these simulations. Overall, cervical arthroplasty did not appear to have a deleterious effect on the dynamic neck response during a simulated rotary-wing aircraft impact. / Ph. D.
|
146 |
On Fixation of Hip ProsthesesPalm, Lars January 2007 (has links)
This thesis, comprising 5 separate studies, is concerned with fixation of prosthetic components in total hip arthroplasty. The results and conclusions of the studies fol-low; The initial stability of femoral revision components, the long cementless PCA stem and the Exeter standard stem cemented in a bed of impacted bone graft, was com-pared in an experimental study. The PCA stem was more stable than the Exeter stem. However, for both stems initial stability may not be sufficient to allow bone ingrowth. Initial fixation is especially vulnerable to torsion. Identical femoral stems with or without HA-coating were compared in a prospec-tive randomized clinical trial. The long-term stable fixation of a cementless Link RS femoral component was improved by application of hydroxyapatite coating to the femoral stem. In a clinical study the method of extensive impaction of morsellized bone allograft and a hydroxyapatite-coated cementless Mallory-Head acetabular component was found to be advantageous for acetabular revision in the presence of contained or acetabular wall defects. The limited contact between the HA-coated implant and living host bone did not seem to compromise long-term stable fixation. Two different cup designs were compared in a prospective randomized RSA study. At 3 years after implantation the cemented low profile Lubinus FAL cup performed as well as the cemented Lubinus Standard cup in terms of migration and polyethyl-ene wear. In a study of the relationship between radiolucent lines and migration the Lubinus FAL cup displayed more radiolucent lines in the cement bone interface than the Lubinus Standard cup but no difference in migration was found. Early appearance of such radiolucent lines represents an unspecific finding without reliable correla-tion to 3-year migration of the acetabular component.
|
147 |
Experiences of abandonment and anonymity among arthroplastic surgery patients in the perioperative period : some issues concerning communication, pain and sufferingSjöling, Mats, January 2005 (has links)
Diss. (sammanfattning) Umeå : Univ., 2005. / Härtill 4 uppsatser.
|
148 |
Análise histológica da neoformação óssea com o uso de enxerto bovino liofilizado / Histological analysis of bone neoformation with the use of lyophilized bovine xenograftRibeiro, Tiango Aguiar January 2015 (has links)
A artroplastia é, em última análise, a opção final para o tratamento da osteoartrose. Com o aumento do número de indicações deste procedimento, a troca (artroplastia total de quadril de revisão – ATQR) dos componentes também passou a ser mais frequente. Os defeitos ósseos ou falhas ósseas são problemas que podem ser encontrados quando se realiza uma ATQR e, eles devem ser reparados, ou seja, o quadril do paciente a receber outra prótese necessita ser reconstruído. Para isto a grande maioria das técnicas empregadas requer o uso de enxerto ósseo e, devido a este motivo este tecido tem se tornado um dos tecidos mais transplantados na atualidade. Porém a demanda para utilização dos enxertos, na maioria provenientes de bancos de tecidos ósseos, tem aumentado, mas o suprimento é insuficiente. Portanto faz-se necessário a busca por novas tecnologias e alternativas aos bancos de tecidos. O enxerto bovino liofilizado (EBL) é uma destas opções, sua produção em livre demanda suas características físicas e químicas semelhantes ao osso humano e sua boa repercussão clínico-radiológica o torna uma alternativa viável. Este estudo tem o objetivo de verificar e quantificar a neoformação óssea com o uso do EBL pelo uso da avaliação histológica. Realizou-se um estudo de casos de Julho de 2000 a Abril de 2013 no Hospital de Clínicas de Porto Alegre (HCPA), onde se incluíram sujeitos que foram submetidos a uma cirurgia prévia cirurgia de ATQR onde foi utilizado o EBL os quais internaram posteriormente para uma segunda cirurgia de ATQR não relacionada a falha do enxerto e sim a falha da prótese. Nesta segunda cirurgia realizou-se a biópsia óssea. Quatorze sujeitos foram analisados, sendo 64,3% do sexo feminino. A média de idade dos pacientes foi 52,36±18,55. Neoformação óssea estava presente em 85,7% dos sujeitos, e constituiu 61,79% da área total de matriz óssea. O diagnóstico de absorção do EBL estava presente em 12 sujeitos. Uma forte correlação de proporção inversa foi constatada pelo teste de Pearson entre a porcentagem de osso neoformado e a porcentagem de EBL na área total de matriz óssea (p=0,001). Nenhuma resposta inflamatória foi encontrada. Concluiu-se que houve neoformação óssea adequada na grande maioria dos casos sendo o EBL uma boa estrutura osteocondutora, podendo ser considerado uma alternativa aos outros enxertos ósseos no tratamento das falhas ósseas. / Arthroplasty is, ultimately, the final option for the treatment of osteoarthritis. With the increasing number of indications of this procedure, the exchange (total hip arthroplasty revision surgery- THARS) also became more frequent. The bone defects are problems that can be encountered when conducting a THARS and this defect must be repaired, in other words, the patient's hip needs to be rebuilt before receive a new prosthesis. Most of techniques used to rebuild requires the use of bone graft, and because of this reason, this tissue has become one of the most transplanted tissues today. However the demand for the use of grafts, mostly from bone tissue banks, has increased, but the supply is insufficient. Therefore it is necessary to search for new technologies and alternatives to tissue banks. The bovine lyophilized xenograft (BLX) is one of these options; the production on free demand, its physical and chemical characteristics similar to human bone and its good clinical and radiological outcomes makes it a viable alternative. The aim of this study was to verify and quantify new bone formation by the histological analysis in subjects who received the BLX. This was a case series from July 2000 to April 2013 realized in the Hospital de Clínicas de Porto Alegre. This study included patients who underwent to a THARS where was used the BLX, which later was admitted to a second THARS surgery, not related to the xenograft failure but a mechanical failure of the implant. In this second surgery was performed the bone biopsy. Fourteen subjects were analyzed, 64.3% were female. The average age of patients was 52.36 ± 18.55 years. New bone formation was present in 85.7% of subjects, and constituted 61.79% of the total bone matrix. The diagnosis of BLX absorption was present in 12 subjects. A strong inverse correlation founded by the Pearson's test was observed between the proportion of new bone and the proportion of BLX (p=0.001). No inflammatory response was found. Was concluded that there was suitable bone formation in the vast majority of the cases, as well as the BLX is a good osteoconductive scaffold and can be considered an alternative to other bone graft in the treatment of bone defects.
|
149 |
Análise histológica da neoformação óssea com o uso de enxerto bovino liofilizado / Histological analysis of bone neoformation with the use of lyophilized bovine xenograftRibeiro, Tiango Aguiar January 2015 (has links)
A artroplastia é, em última análise, a opção final para o tratamento da osteoartrose. Com o aumento do número de indicações deste procedimento, a troca (artroplastia total de quadril de revisão – ATQR) dos componentes também passou a ser mais frequente. Os defeitos ósseos ou falhas ósseas são problemas que podem ser encontrados quando se realiza uma ATQR e, eles devem ser reparados, ou seja, o quadril do paciente a receber outra prótese necessita ser reconstruído. Para isto a grande maioria das técnicas empregadas requer o uso de enxerto ósseo e, devido a este motivo este tecido tem se tornado um dos tecidos mais transplantados na atualidade. Porém a demanda para utilização dos enxertos, na maioria provenientes de bancos de tecidos ósseos, tem aumentado, mas o suprimento é insuficiente. Portanto faz-se necessário a busca por novas tecnologias e alternativas aos bancos de tecidos. O enxerto bovino liofilizado (EBL) é uma destas opções, sua produção em livre demanda suas características físicas e químicas semelhantes ao osso humano e sua boa repercussão clínico-radiológica o torna uma alternativa viável. Este estudo tem o objetivo de verificar e quantificar a neoformação óssea com o uso do EBL pelo uso da avaliação histológica. Realizou-se um estudo de casos de Julho de 2000 a Abril de 2013 no Hospital de Clínicas de Porto Alegre (HCPA), onde se incluíram sujeitos que foram submetidos a uma cirurgia prévia cirurgia de ATQR onde foi utilizado o EBL os quais internaram posteriormente para uma segunda cirurgia de ATQR não relacionada a falha do enxerto e sim a falha da prótese. Nesta segunda cirurgia realizou-se a biópsia óssea. Quatorze sujeitos foram analisados, sendo 64,3% do sexo feminino. A média de idade dos pacientes foi 52,36±18,55. Neoformação óssea estava presente em 85,7% dos sujeitos, e constituiu 61,79% da área total de matriz óssea. O diagnóstico de absorção do EBL estava presente em 12 sujeitos. Uma forte correlação de proporção inversa foi constatada pelo teste de Pearson entre a porcentagem de osso neoformado e a porcentagem de EBL na área total de matriz óssea (p=0,001). Nenhuma resposta inflamatória foi encontrada. Concluiu-se que houve neoformação óssea adequada na grande maioria dos casos sendo o EBL uma boa estrutura osteocondutora, podendo ser considerado uma alternativa aos outros enxertos ósseos no tratamento das falhas ósseas. / Arthroplasty is, ultimately, the final option for the treatment of osteoarthritis. With the increasing number of indications of this procedure, the exchange (total hip arthroplasty revision surgery- THARS) also became more frequent. The bone defects are problems that can be encountered when conducting a THARS and this defect must be repaired, in other words, the patient's hip needs to be rebuilt before receive a new prosthesis. Most of techniques used to rebuild requires the use of bone graft, and because of this reason, this tissue has become one of the most transplanted tissues today. However the demand for the use of grafts, mostly from bone tissue banks, has increased, but the supply is insufficient. Therefore it is necessary to search for new technologies and alternatives to tissue banks. The bovine lyophilized xenograft (BLX) is one of these options; the production on free demand, its physical and chemical characteristics similar to human bone and its good clinical and radiological outcomes makes it a viable alternative. The aim of this study was to verify and quantify new bone formation by the histological analysis in subjects who received the BLX. This was a case series from July 2000 to April 2013 realized in the Hospital de Clínicas de Porto Alegre. This study included patients who underwent to a THARS where was used the BLX, which later was admitted to a second THARS surgery, not related to the xenograft failure but a mechanical failure of the implant. In this second surgery was performed the bone biopsy. Fourteen subjects were analyzed, 64.3% were female. The average age of patients was 52.36 ± 18.55 years. New bone formation was present in 85.7% of subjects, and constituted 61.79% of the total bone matrix. The diagnosis of BLX absorption was present in 12 subjects. A strong inverse correlation founded by the Pearson's test was observed between the proportion of new bone and the proportion of BLX (p=0.001). No inflammatory response was found. Was concluded that there was suitable bone formation in the vast majority of the cases, as well as the BLX is a good osteoconductive scaffold and can be considered an alternative to other bone graft in the treatment of bone defects.
|
150 |
Análise histológica da neoformação óssea com o uso de enxerto bovino liofilizado / Histological analysis of bone neoformation with the use of lyophilized bovine xenograftRibeiro, Tiango Aguiar January 2015 (has links)
A artroplastia é, em última análise, a opção final para o tratamento da osteoartrose. Com o aumento do número de indicações deste procedimento, a troca (artroplastia total de quadril de revisão – ATQR) dos componentes também passou a ser mais frequente. Os defeitos ósseos ou falhas ósseas são problemas que podem ser encontrados quando se realiza uma ATQR e, eles devem ser reparados, ou seja, o quadril do paciente a receber outra prótese necessita ser reconstruído. Para isto a grande maioria das técnicas empregadas requer o uso de enxerto ósseo e, devido a este motivo este tecido tem se tornado um dos tecidos mais transplantados na atualidade. Porém a demanda para utilização dos enxertos, na maioria provenientes de bancos de tecidos ósseos, tem aumentado, mas o suprimento é insuficiente. Portanto faz-se necessário a busca por novas tecnologias e alternativas aos bancos de tecidos. O enxerto bovino liofilizado (EBL) é uma destas opções, sua produção em livre demanda suas características físicas e químicas semelhantes ao osso humano e sua boa repercussão clínico-radiológica o torna uma alternativa viável. Este estudo tem o objetivo de verificar e quantificar a neoformação óssea com o uso do EBL pelo uso da avaliação histológica. Realizou-se um estudo de casos de Julho de 2000 a Abril de 2013 no Hospital de Clínicas de Porto Alegre (HCPA), onde se incluíram sujeitos que foram submetidos a uma cirurgia prévia cirurgia de ATQR onde foi utilizado o EBL os quais internaram posteriormente para uma segunda cirurgia de ATQR não relacionada a falha do enxerto e sim a falha da prótese. Nesta segunda cirurgia realizou-se a biópsia óssea. Quatorze sujeitos foram analisados, sendo 64,3% do sexo feminino. A média de idade dos pacientes foi 52,36±18,55. Neoformação óssea estava presente em 85,7% dos sujeitos, e constituiu 61,79% da área total de matriz óssea. O diagnóstico de absorção do EBL estava presente em 12 sujeitos. Uma forte correlação de proporção inversa foi constatada pelo teste de Pearson entre a porcentagem de osso neoformado e a porcentagem de EBL na área total de matriz óssea (p=0,001). Nenhuma resposta inflamatória foi encontrada. Concluiu-se que houve neoformação óssea adequada na grande maioria dos casos sendo o EBL uma boa estrutura osteocondutora, podendo ser considerado uma alternativa aos outros enxertos ósseos no tratamento das falhas ósseas. / Arthroplasty is, ultimately, the final option for the treatment of osteoarthritis. With the increasing number of indications of this procedure, the exchange (total hip arthroplasty revision surgery- THARS) also became more frequent. The bone defects are problems that can be encountered when conducting a THARS and this defect must be repaired, in other words, the patient's hip needs to be rebuilt before receive a new prosthesis. Most of techniques used to rebuild requires the use of bone graft, and because of this reason, this tissue has become one of the most transplanted tissues today. However the demand for the use of grafts, mostly from bone tissue banks, has increased, but the supply is insufficient. Therefore it is necessary to search for new technologies and alternatives to tissue banks. The bovine lyophilized xenograft (BLX) is one of these options; the production on free demand, its physical and chemical characteristics similar to human bone and its good clinical and radiological outcomes makes it a viable alternative. The aim of this study was to verify and quantify new bone formation by the histological analysis in subjects who received the BLX. This was a case series from July 2000 to April 2013 realized in the Hospital de Clínicas de Porto Alegre. This study included patients who underwent to a THARS where was used the BLX, which later was admitted to a second THARS surgery, not related to the xenograft failure but a mechanical failure of the implant. In this second surgery was performed the bone biopsy. Fourteen subjects were analyzed, 64.3% were female. The average age of patients was 52.36 ± 18.55 years. New bone formation was present in 85.7% of subjects, and constituted 61.79% of the total bone matrix. The diagnosis of BLX absorption was present in 12 subjects. A strong inverse correlation founded by the Pearson's test was observed between the proportion of new bone and the proportion of BLX (p=0.001). No inflammatory response was found. Was concluded that there was suitable bone formation in the vast majority of the cases, as well as the BLX is a good osteoconductive scaffold and can be considered an alternative to other bone graft in the treatment of bone defects.
|
Page generated in 0.1406 seconds