Spelling suggestions: "subject:"assimétrica"" "subject:"assimétricas""
11 |
Amplitude de pulso ocular em pacientes portadores de glaucoma primário de ângulo aberto assimétricoKac, Marcelo Jarczun January 2010 (has links)
Submitted by Ana Lúcia Torres (bfmhuap@gmail.com) on 2017-10-04T13:45:33Z
No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
DISSERTAÇAO MARCELO JARCZUN KAC.pdf: 1310344 bytes, checksum: 894e8b8ff1bbb98f54524b2bf42cfdc9 (MD5) / Approved for entry into archive by Ana Lúcia Torres (bfmhuap@gmail.com) on 2017-10-04T13:45:45Z (GMT) No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
DISSERTAÇAO MARCELO JARCZUN KAC.pdf: 1310344 bytes, checksum: 894e8b8ff1bbb98f54524b2bf42cfdc9 (MD5) / Made available in DSpace on 2017-10-04T13:45:45Z (GMT). No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
DISSERTAÇAO MARCELO JARCZUN KAC.pdf: 1310344 bytes, checksum: 894e8b8ff1bbb98f54524b2bf42cfdc9 (MD5)
Previous issue date: 2010 / Prefeitura da Cidade do Rio de Janeiro / Objetivo: Avaliar a amplitude de pulso ocular (APO) utilizando o tonômetro de contorno dinâmico (TCD) em pacientes com glaucoma primário de ângulo aberto (GPAA) assimétrico e pressão intra-ocular (PIO) assimétrica. Métodos: 48 pacientes (96 olhos) com GPAA assimétrico foram recrutados. Três medidas da PIO e da APO foram aferidas utilizando o TCD. Para o diagnóstico de assimetria eram necessárias uma diferença de perda de campo visual maior que 6 dB no índice “mean deviation” (MD), e uma diferença de 5 mmHg na PIO medida com o tonômetro de aplanação de Goldmann (TAG) entre o olho mais afetado e o contra-lateral. Todos os participantes se submeteram a um exame oftalmológico completo, incluindo paquimetria ultrassônica e ecobiometira. Os critérios de exclusão consistiram de: doenças ou cicatrizes corneanas, uso de medicação anti-glaucomatosa tópica ou sistêmica e cirurgia ocular prévia. Resultados: Não houve diferença com significância estatística (p = 0,142) entre o comprimento axial dos olhos do grupo melhor (22,95 +/- 0,91 mm) e pior (22,85 +/- 0,97 mm). Houve diferença estatisticamente significativa (p = 0,011) entre a espessura corneana central do grupo de olhos melhores (537,08 +/- 29,54 μm) e do grupo de olhos piores (534,40 +/- 29,87 μm). Os valores da APO do grupo de olhos melhores (3.32 +/- 1.14 mmHg) foram significativamente menores (p = 0,001) do que os obtidos no grupo de olhos piores (3,83 +/- 1,27 mmHg). Quando corrigimos as medidas de APO pela diferença de PIO entre os olhos houve uma perda da significância estatística entre os grupos (p = 0,996). Conclusão: A APO é semelhante entre os dois olhos de pacientes portadores de GPAA assimétrico com PIO assimétrica. De acordo com esses dados não há evidência de que a APO possa ter um papel no GPAA hipertensivo assimétrico / Aim: To evaluate ocular pulse amplitude (OPA) using the dynamic contour tonometer (DCT) in patients with asymmetric primary open-angle glaucoma (POAG) and asymmetric intra-ocular pressure (IOP). Methods: The participants consisted of 48 patients (96 eyes) with asymmetric POAG. Three measurements of IOP and OPA were taken using DCT. The diagnosis of asymmetry required a difference of glaucomatous visual field loss greater than 6 dB in the global index MD and a difference of 5 mmHg in IOP measured by Goldmann aplannation tonometry (GAT) between the more affected and the contra-lateral eye. All participants underwent full ophthalmologic clinical assessment including ultrasonic pachymetry and biometric measurements. Exclusion criteria were corneal diseases or scars, topical or systemic glaucomatous medications, and previous ocular surgery. Results: No difference (p = 0.142) was found between the axial length measurements of the better eyes group (22.95 +/- 0.91 mm) and worse eyes group (22.85 +/- 0.97 mm). There was a statistically significant difference (p = 0.011) between the central corneal thickness values of the better eyes group (537.08 +/- 29.54 μm) and worse eyes group (534.40 +/- 29.87 μm). The OPA values of the better eyes group (3.32 +/- 1.14 mmHg) were significantly lower (p = 0.001) than those obtained on worse eyes group (3.83 +/- 1.27 mmHg). When correcting the OPA readings by the IOP there was a loss of statistical difference between groups (p = 0.996). Conclusion: OPA is similar in both eyes of asymmetric hypertensive POAG patients with asymmetric IOP. According to this data there was no evidence that OPA could play a role in asymmetric hypertensive POAG
|
12 |
Motor de indução bifásico em rede de alimentação bifásica simétrica com condutor de retornoCastro Neto, Lindolfo Marra de 27 October 2006 (has links)
The main task of this work is to provide a contribution to help a
more deep understanding on the operation of the asymmetrical twophase
induction motor with return for applications in places where a
possibility of a two-phase network feeding exists.
important contributions where obtained with the help of a time
domain dynamic model for symmetrical and asymmetrical two-phase
machines developed as part of this work.
With such contributions it was possible to show that a threephase
induction motor can work as a two-phase asymmetrical
induction motor with return through a phase or neutral conductor,
without the need of some starting devices, such as, centrifugal
switch and capacitors. this was proved through load and no-load
tests and by way of comparisons between theoretical and
experimental results.
Hence, with such a work, we are seeking for the revitalization
of the asymmetrical two-phase induction motor theory, a machine
that presents a non-uniform magnetomotive force and
electromagnetic torque. / O objetivo principal deste trabalho é fornecer uma
contribuição que ajudará no entendimento com maior profundidade
sobre o funcionamento do motor de indução bifásico assimétrico com
retorno para aplicações em locais onde exista a possibilidade de uma
rede de alimentação bifásica.
As contribuições mais importantes foram obtidas com o auxílio
do modelo dinâmico no domínio do tempo para máquinas bifásicas
simétricas e assimétricas desenvolvido neste trabalho.
Através das contribuições obtidas foi possível mostrar que um
motor de indução trifásico pode funcionar como motor de indução
bifásico assimétrico com retorno pela fase ou pelo neutro, sem que o
mesmo necessite de determinados componentes de partida, tais como,
chave centrifuga e capacitores. isto ficou provado através dos
ensaios a vazio e com carga e também por intermédio das comparações
entre os resultados teóricos e experimentais.
Com isto procurou-se revitalizar a teoria do motor de indução
bifásico assimétrico com retorno, que possui força magnetomotriz e
torque eletromagnético não uniforme. / Doutor em Ciências
|
13 |
Avaliação de desempenho do gerador de indução trifásico assimétrico conectado a uma rede monofásica - aplicações rurais / Evaluation of performance of the assymmetrical three - phase induction generator connected to single-phase supply system rural applicationsCarvalho, Hamilton Dias de 30 June 2006 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / This work has for motive to obtain the project and build of an
assymmetrical three-phase induction generator connected to single-phase supply
system, in order to be used in rural areas. This equipment has been presented as
a better alternative in relation the others proposed more commercialized at the
moment, due to its robustness, low cost, less maintenance requirements and
excellent performance. Firstly, in the theoric part concerned to the system it is
presented a mathematical representation, frequency domain mathematical
model, whose equations are performed in function of an unbalance factor in
order to obtain balance three-phase voltages in the system. Then, some
simulations are performed in the simulator that was developed in the Microsoft
Excel program. From these implements, it is carried out study cases to prove the
assymmetrical three-phase induction generator use potentialities. A prototype is
projected and built, which experimental results are compared to the computer
result. / O objetivo deste trabalho é obter o projeto e a construção de um gerador de
indução trifásico assimétrico conectado a um sistema de distribuição de energia
elétrica monofásica; visando aplicá-lo em áreas rurais. Este dispositivo, em face
de sua robustez, baixo custo, menores requisitos de manutenção e bom
desempenho, consiste numa alternativa bastante atrativa em relação às outras
propostas existentes atualmente. O estudo teórico inicia-se através da elaboração
de uma modelagem matemática para o sistema, no domínio da freqüência, cujas
equações são colocadas em função de um fator indicativo do nível de
desbalanceamento, visando à obtenção de tensões balanceadas na carga. Para
tanto, a modelagem matemática elaborada é implementada num simulador
desenvolvido no programa Microsoft Excel. A partir desta implementação, são
efetuados estudos de casos no sentido de evidenciar as potencialidades do
gerador assimétrico conectado a cargas rurais. Os trabalhos computacionais são
devidamente validados à luz de resultados experimentais extraídos de um
protótipo de equipamento concebido, projetado e construído para fins deste
trabalho. / Mestre em Ciências
|
Page generated in 0.0632 seconds