• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 448
  • 7
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 467
  • 264
  • 221
  • 172
  • 155
  • 120
  • 118
  • 116
  • 108
  • 106
  • 64
  • 62
  • 58
  • 52
  • 51
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
281

Combinaçäo de adsorçäo por carväo ativado com processo oxidativo avançado (POA) para tratamento de efluentes contendo fenol. / Combination of adsorption by activated carbon with advanced oxidation process (AOP) for the treatment of wastewater containing phenol.

CÍnthia Tiemi Muranaka 25 June 2010 (has links)
O processo de adsorção por carvão ativado é uma técnica muito aplicada para tratamento de efluentes. Porém o tratamento que envolve adsorção não é um sistema completo, pois há a necessidade da destruição dos compostos que foram imobilizados na superfície do carvão. Frente a esse problema, métodos alternativos de regeneração de carvão ativado são investigados. Os processos Fenton e foto-Fenton são considerados tecnologias promissoras de tratamento de efluentes, e foram testados para regenerar o carvão ativado. Este trabalho objetiva estudar a adsorção de fenol em carvões ativados (CAs) e a consecutiva regeneração in-situ do carvão pela oxidação de (foto-) Fenton. Duas operações diferentes foram realizadas: 1) sistema de batelada, a fim de investigar a influência das concentrações de Fe2+ e H2O2; 2) adsorção contínua em leito fixo, seguido de circulação em batelada dos reagentes de Fenton pelo leito de CA saturado, para examinar a eficiência do processo real. Foram estudados dois tipos de carvão ativado: CA L27 (meso e microporoso) e CA S23 (somente microporoso). No reator de batelada as melhores condições encontradas para a mineralização do poluente no sistema Fenton homogêneo não são as melhores para a regeneração do CA: foi observada uma redução contínua da capacidade de adsorção do L27 após 3 oxidações, devido à redução tanto da massa do CA quanto da área superficial. Uma maior concentração de Fe2+ e menor concentração de H2O2 (2 vezes a estequiometria) levou a uma recuperação de 50% da capacidade de adsorção inicial em pelo menos 4 ciclos consecutivos para o L27, enquanto que cerca de 20% para o S23. No processo consecutivo de adsorção contínua/oxidação de Fenton em batelada, a eficiência de regeneração atinge de 30% a 40% para o L27 após dois ciclos independente da concentração da alimentação e menos de 10% para o S23. O processo foto-Fenton realizado para o L27 levou à quase completa mineralização e aumentou a recuperação da capacidade de adsorção do CA (56% após dois ciclos). / The adsorption process by active carbon is a technique applied extensively for wastewater treatment. However the tertiary treatment involving adsorption is not a complete system, since there is a need of destruction of the compounds that were immobilized on the carbon surface. In face of this problem, some alternative regeneration methods of active carbon are investigated. Fenton and photo-Fenton processes have been considered promising technologies for wastewater treatment and have been tested to regenerate the AC. The purposes of this study are the adsorption of phenol on activated carbons (ACs) and the consecutive in-situ regeneration of carbon by (photo-) Fenton oxidation. Two different operations have been carried out: 1) batch procedure in order to investigate the influence of Fe2+ and H2O2 concentrations; 2) continuous fixed bed adsorption, followed by a batch circulation of the Fentons reagent through the saturated AC bed, to examine the efficiency of the real process. Two different activated carbons have been also studied: a both micro- and mesoporous AC (L27) and an only microporous one (S23). In the batch reactor the best conditions found for pollutant mineralization in the homogeneous Fenton system are not the best for AC regeneration: a continuous reduction of adsorption capacity of L27 is observed after 3 oxidations, due to the decrease of both AC weight and surface area. Higher concentration of Fe2+ and lower concentration of H2O2 (2 times the stoechiometry) lead to a 50% recovery of the initial adsorption capacity during at least 4 consecutive cycles for L27, while about 20% for S23. In the consecutive continuous adsorption/batch Fenton oxidation process, the regeneration efficiency reaches 30% to 40% for L27 after two cycles whatever the feed concentration and less than 10% for S23. A photo- Fenton test performed on L27 shows almost complete mineralization (contrary to dark Fenton) and further improves recovery of AC adsorption capacity although not complete (56% after two cycles).
282

Comparação do desempenho de carvão ativado produzido a partir de diferentes matrizes para remoção de microcistina-LR de águas de abastecimento / Comparison of the performance of activated carbon produced from different raw materials for microcystin-LR removal from water supply

Larissa Sene Araújo 07 March 2017 (has links)
A expansão agrícola e a urbanização têm agravado a eutrofização artificial dos mananciais superficiais, devido ao aumento de seus níveis de nutrientes, como nitrogênio e fósforo. Nesses episódios, o crescimento excessivo de cianobactérias de elevada capacidade adaptativa e potencial de produção de cianotoxinas pode prejudicar homens e animais. As microcistinas estão entre as cianotoxinas mais encontradas em florações de cianobactérias tóxicas, de difícil remoção pelas tecnologias convencionais de Estações de Tratamento de Água (ETA). Como barreira adicional no tratamento avançado de águas de abastecimento, destaca-se o processo de adsorção com carvão ativado pulverizado (CAP) ou granular (CAG). Esta pesquisa avaliou a eficiência de remoção de microcistina-LR (MC-LR) por oito carvões ativados (7 CAGs e 1 CAP) produzidos a partir de matérias-primas diversificadas. Os carvões foram caracterizados quanto a umidade, teor de cinzas, pH, massa específica aparente, número de iodo, índice de azul de Metileno, coeficiente de desuniformidade, área superficial específica, volume de micro e mesoporos, análise elementar por Espectroscopia de Energia Dispersiva e fotomicrografia por Microscopia Eletrônica de Varredura. Avaliou-se a capacidade adsortiva dos carvões sobre a MC-LR por isotermas descritas pelos modelos matemáticos de Langmuir e Freundlich. Para tais ensaios, foram utilizadas amostras trituradas de carvão. Além disso, foram operadas quatorze colunas CAG em escala de bancada, de modo intermitente, com concentração inicial (Co) de MC-LR na faixa de 69 a 137 µg/L. A concentração de toxina foi estimada pelo método ELISA (Ensaio de Imunoadsorção Enzimática). Os resultados indicaram que as propriedades do CA são influenciadas por seu material de origem e também pelo seu modo de produção, e que tais propriedades têm reflexo direto sobre a eficiência de remoção de MC-LR. Nos ensaios de adsorção de MC-LR com as amostras trituradas, os dados se ajustaram melhor ao modelo de Langmuir. O carvão à base de linhito (CGLIN), em dosagem de 100,0 mg/L e com 4h de tempo de contato, apresentou a maior capacidade de remoção (97,2%) de MC-LR (Co: 115,1 µg/L), com qe,máx de 10,6 mg/g. O bom desempenho do CGLIN foi associado ao seu maior volume de mesoporos (0,53 cm3/g). Correlação significativa foi observada entre volume de mesoporos e qe,máx (r = 0,98, Pearson), o que foi corroborado pela Análise de Componentes Principais. Nos ensaios nas colunas de CAG, o carvão de hulha, CGHU (Co: 85 g/L) apresentou o melhor desempenho, seguido pelo carvão de casca de coco, CGCO4 (Co: 137 µg/L), ambos com remoção média de MC-LR de 99,5%. Nos ensaios com as amostras trituradas, nenhuma das dosagens removeu MC-LR a concentrações menores que 1,0 µg/L – valor máximo permitido pela Portaria MS nº 2.914/11 para água potável – enquanto que no início do tratamento com as colunas de CAG, com exceção do carvão de coco CGCO1, o efluente das demais amostras foi compatível com este limite. A divergência de resultados entre os dois tipos de ensaios indica que os experimentos com amostras de CAG trituradas podem alterar sua capacidade adsortiva e induzir a uma escolha incorreta do carvão mais adequado. Com isso, os resultados oferecem subsídios para o entendimento do desempenho das CAs sobre a remoção de cianotoxinas, amparando a aplicação do processo de adsorção em ETAs para minimização da incidência de intoxicações por água contaminada. / The agricultural expansion and urbanization has aggravated the artificial eutrophication of surface water sources, due to the increase of nutrient levels, such as nitrogen and phosphorus. In these episodes, the excessive growth of cyanobacteria of high adaptive capacity and potential to produce cyanotoxins can harm humans and animals. Microcystins are among the cyanotoxins most found in toxic cyanobacteria blooms, difficult to remove by conventional technologies of Water Treatment Plants (WTP). As an additional barrier in the advanced water treatment, the adsorption process with pulverized (PAC) or granular activated carbon (GAC) is highlighted. This research evaluated the efficiency of microcystin-LR (MC-LR) removal by eight activated carbons (7 GACs and 1 PAC) produced from diversified raw materials. The carbons were characterized by moisture, ash content, pH, bulk density, iodine number, Methylene blue index, desuniformity coefficient, specific surface area, micro and mesopore volume, elemental analysis by Energy Dispersive X-Ray Detector and photomicrography by Scanning Electron Microscopy. The MC-LR adsorptive capacity of the carbons was evaluated by isotherms that follow the mathematical models of Langmuir and Freundlich. For these tests, carbon crushed samples were used. Besides that, fourteen GAC columns were operated on bench scale, intermittently, with initial concentration (Co) of MC-LR in the range of 69 to 137 µg/L. The toxin concentration was measured by ELISA (Enzyme-Linked Immunosorbent Assay). The results indicate that the AC properties are influenced by their source material and also by their production mode, and these properties have a direct effect on the efficiency of MC-LR removal. In the adsorption tests of MC-LR with the AC crushed samples, the data were better fitted to the Langmuir model. The lignite-based carbon (CGLIN), at a dosage of 100.0 mg/L and 4h of contact time, presented the highest MC-LR (Co: 115.1 µg/L) removal capacity (97.2%), with a qe,máx of 10.6 mg/g. The good performance of CGLIN was associated with its higher volume of mesopores (0.53 cm3/g). Significant correlation was observed between volume of mesopores and qe,max (r = 0.98, Pearson), which was corroborated by Principal Component Analysis. In the GAC columns tests, the coal CGHU (Co: 85 µg/L) presented the best performance, followed by the coconut carbon CGCO4 (Co: 137 µg/L), both with MC-LR average removal from 99.5%. In the trials with the crushed samples, none of the dosages removed MC-LR at values less than 1.0 µg/L – maximum permitted value by Portaria MS nº 2.914/11 for drinking water – while at the beginning of the treatment in the GAC columns, with the exception of the coconut carbon CGCO1, the effluent of the other samples was compatible with this limit. The divergence of results between these two types of assays indicates that the experiments with crushed samples may changes their adsorptive capacity and induce an incorrect choice of the most suitable AC. With this, the results provide support to understand the ACs performance on the cyanotoxins removal, supporting the application of the adsorption process in WTPs to minimize the incidence of poisoning by contaminated water.
283

Tratamento de água para abastecimento contendo cianobactérias e microcistina em sistemas constituído por etapas de pré-cloração, coagulação/floculação, flotação e adsorção em carvão ativado / Drinking-water treatment with cyanobacteria and microcistin in a system composed by stages of preoxidation, coagulation/flocculation, flotation and adsorption on activated carbon

Fernando Brisola de Almeida Bueno 13 May 2005 (has links)
A captação de água para abastecimento público, a cada dia, torna-se mais problemática devido ao grande número de mananciais eutrofizados. A eutrofização causa grande preocupação, pois é comum o surgimento de florações com presença de organismos fitoplanctônicos potenciais produtores de toxinas nocivas à saúde. Entre essas toxinas a grande contaminadora é a microcistina produzida por cianobactérias - tóxico potente que causa sérios agravos à saúde e pode levar à morte. Este trabalho de pesquisa testou alguns processos de tratamento de água - pré-oxidação, coagulação/floculação, flotação por ar dissolvido e adsorção em carvão ativado - com o propósito de verificar quão eficientes eles seriam na remoção dessa toxina. Em escala de laboratório foram realizados ensaios de coagulação/floculação, seguidos de flotação sem adição e com adição de pré-oxidante e carvão ativado em pó. Para a água de estudo verificou-se que o baixo pH é fator positivo para o tratamento. A pré-oxidação aplicada ao tratamento apresentou bons resultados na remoção de microcistina; o tempo de contato do oxidante também exerceu influência na qualidade. A associação de pré-oxidação e adsorção em carvão ativado elevou a eficiência de remoção de toxina. Embora os sistemas convencionais de tratamento de água não sejam eficientes na remoção de microcistina a flotação é melhor que a sedimentação. / At each day, the captivation of water for public supplying is becoming more difficult because of the emerging blooming with the presence of phitoplanktonic organisms which in turn are potential producer of harmful toxins to the health. Among those toxins the major contaminant is the microcistin produced by cyanobacteria - a powerful toxin that causes serious hazards to the health being able also to cause death. In this work the investigation had tested some water treatment processes - preoxidation, coagulation/flocculation, dissolved air flotation and adsorption on activated carbon - with the purpose to check how efficient they would be to remove that toxin. In the laboratory assays, coagulation/flocculation followed by flotation were performed with and without addition of preoxidant and activated carbon powder. In this study, the pH demonstrated to be a positive factor for the treatment. The preoxidation applied to the treatment presented good results in the microcistina removing; the oxidant contact time also played influence in the quality; the association of preoxidant and adsorption on activated carbon just raised the toxin remotion efficiency. Although the conventional water treatment systems are not efficient in the microcistina removal, the flotation is better than sedimentation.
284

Efeitos proporcionados à biomassa em sistemas de tratamento de esgostos por lodos ativados pelos fármacos levamisol, trimetropim e sulfadiazina / Effects caused by drugs: levamisole, trimethoprim and sulfadizine in biomass of the activated sludge wastewater treatment system

Plazza, Fernanda Fagali, 1980- 23 August 2018 (has links)
Orientador: Alexandre Nunes Ponezi / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-23T11:51:30Z (GMT). No. of bitstreams: 1 Plazza_FernandaFagali_M.pdf: 1550925 bytes, checksum: acc23d51c4787771e54a42e2d77cb069 (MD5) Previous issue date: 2013 / Resumo: A biomassa de uma estação de tratamento de lodo ativado é capaz de se adaptar ao efluente recebido, mesmo quando esse contém contaminantes específicos no meio. Fármacos são considerados contaminantes emergentes e lançados no sistema de tratamento a partir de descargas de estações de tratamento de águas residuais pela indústria (pontual) e na aplicação no solo pelo esterco (difusa) gerado pelos animais, como uma mistura de metabolitos e formas ativas. Para a realização deste trabalho foram escolhidos os antibióticos: sulfadiazina e trimetropim, e o anti-helmíntico: levamisol; devido: produção em larga escala e efeito quimioterápico provável na biomassa de estações de tratamento de efluentes. Os ensaios realizados conforme OECD: 209/2010 inibição da respiração do lodo ativado e 303/2001 simulação de tratamento com lodos ativados, mostraram que a taxa de inibição do lodo (ensaio 209/2010) foi proporcional à concentração utilizada (0,005 mg L-1 a 20,0 mg L-1) para a sulfadiazina, levamisol e trimetropim respectivamente tanto para o lodo com origem de estação doméstica convencional como para o lodo de estação de efluentes da industria farmacêutica (industrial), sendo este último o que apresentou menor inibição. Os ensaios 303/2001 realizados nas concentrações de 1, 5 e 10 mg L-1 mostraram que o lodo industrial apresentou os melhores resultados de biodegradação sendo observada uma remoção abaixo do limite de detecção da cromatografia gasosa acoplada ao espectro de massas (CG-MS) para o levamisol e trimetropim. A sulfadiazina não foi biodegradada durante o processo. Ensaios de toxicidade do efluente gerado pelo ensaio 303/2001 utilizando Vibrio fisheri como organismo-teste mostraram que estes não apresentam toxicidade / Abstract: The biomass of a wastewater treatment activated sludge is able to adapt to the effluent, even when it contains specific contaminants in the middle. Emerging Drugs are considered contaminants and discharged into the treatment discharges from sewage treatment plants w g were chosen drugs sulfadiazine, trimethoprim and levamisole due to: large-scale production and chemotherapeutic effect likely in biomass treatment plant effluents and domestic industry. Tests performed OECD 209/2010 respiration inhibition of activated sludge and 303/2001 simulating activated sludge treatment, showed that the rate of inhibition of the sludge test (209/2010) was proportional to the concentration used (0.005 mg to 20.0 mg L-1) for sulfadiazine, levamisole, and trimethoprim respectively both for domestic and industrial sludge, the latter being the one with less inhibition. The tests 303/2001 performed at concentrations of 1, 5 and 10 mg L-1 showed that the industrial sludge showed the best results being observed biodegradation removal below the limit of detection (GC-MS) for levamisole, and trimethoprim. Sulfadiazine was not biodegraded in the process. Toxicity tests of the effluent generated by the test 303/2001Vibrio fisheri using as test organisms showed that these did not exhibit toxicity / Mestrado / Saneamento e Ambiente / Mestra em Engenharia Civil
285

Estudo do tratamento de aguas residuarias por lodo ativado em reator "air-lift" de tubos concentricos / Study of treatment of waste water by activated sludge in the reactor "air-lift" of concentric tubes

Alberte, Tania Maria 13 March 2003 (has links)
Orientador : Ranulfo Monte Alegre / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Alimentos / Made available in DSpace on 2018-08-03T14:22:54Z (GMT). No. of bitstreams: 1 Alberte_TaniaMaria_D.pdf: 9835439 bytes, checksum: 74ab1a7efc7d568bc9c3b37f762f08ec (MD5) Previous issue date: 2003 / Resumo: Reatores "air-lift" são uma classe especial de coluna de bolhas, sendo recentemente utilizados em processos químicos, bioquímicos e em tratamento de águas residuárias. Neste trabalho, estudou-se o desempenho de um reator "air-lift" de tubos concêntricos no tratamento de água residuária sintética utilizando Iodo ativado. O reator construido de aço-inox, com tubos de aeração e reciclo de 1,2 e 1,5 m respectivamente, foi alimentado com água residuária sintética, sendo o Iodo separado em sedimentador na parte superior do reator e reciclado ao mesmo. A pressão manométrica no reator variou de O a 1,2 Kgf.cm-2, vazão de ar de 200 a 1600 mL.min-1 e vazão de substrato de 200 a 400 mL.h-1. Para cada taxa de alimentação, vazão de ar e pressão, o reator foi operado de forma contínua até que o estado estacionário hidráulico e microbiológico fossem atingidos. As amostras foram retiradas na altura média do reator e análises da Demanda Química de Oxigênio (DQO) e biomassa (quantificada como sólidos suspensos voláteis - SSV) foram feitas de acordo com métodos descritos pelo "Standard Methods for the Examination of Water and Wastewater" (1985). Os três parâmetros, vazão de alimentação, vazão de ar e pressão, variaram gradativamente, além da concentração de DQO do substrato (1100 a 8600 mgDQO.L-1), de forma que foi possível aumentar a concentração de Iodo no reator (SSV) de 1010 a 15000 mgSSV.L-1, sendo este último valor cerca de cinco vezes maior que os de processos convencionais de Iodo ativado, que é de 2000 a 3000 mgSSV.L -1 (Ramalho, 1983). Isto permitiu aumentar a eficiência de redução de DQO de 47 a 87%, respectivamente para reator operado a pressão ambiente e com variação de pressão. O coeficiente de transferência de oxigênio (K1a) aumentou com o aumento da vazão de ar até o limite de 1000 mL.min-1 (5,41 h-1), decrescendo para vazões superiores a esta, possivelmente devido à coalescência de bolhas. O coeficiente de retenção de gás (Eg) foi determinado e, para as vazões de ar testadas (200 a 1400 mL.min-1), variou de 2,08.10-3 a 12,95.10-3, proporcionalmente às vazões de ar utilizadas / Abstract: Air lift reaetors are a speeial elass of bubble eolumns and are been reeently used in ehemieal and bioehemical processes, as well as in wastewater treatment. In this work, it was studied the performanee of aeoneentrie tube air lift reaetor in the synthetie wastewater treatment by aetivated sludge. The reaetor was eonstrueted of stainless steel, 1.2 m high of riser and 1.5 m high of downeomer. It was fed with synthetie wastewater and the sludge was separeted in a sedimentator in the top of reaetor and reeyeled. The manometrie pressure varied from O to 1.2 kgf.em'2, the air flow rate from 200 to 1,600 mL.min-1 and the feed solution from 200 to 400 mL.h -1. To eaeh feed solution of synthetie wastewater rate, air flow rate and pressure, the reaetor was operated in eontinuous form until the hidraulie and mierobiologieal steady-state was reaehed. The samples were eolleeted in the half of the reaetor. Chemieal oxygen demand (COO) and volatils solids eoneentration (VSS) was determinated aceording to ín Standard Methods for the Examínation of Water and Wastewater (1985). Feed solution rate, air flow rate and pressure rangedgradually, as well as eoneentration of feed synthetie wastewater (1,100 of 8,600 mgCOO.L- / Doutorado / Doutor em Engenharia de Alimentos
286

Tratamento de efluente textil e lodo gerado em um sistema de lodos ativados por batelada com adição de carvão ativado em po

Chavez Porras, Alvaro 28 November 2002 (has links)
Orientador : Ricardo de Lima Isaac / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil / Made available in DSpace on 2018-08-03T22:21:11Z (GMT). No. of bitstreams: 1 ChavezPorras_Alvaro_M.pdf: 6504714 bytes, checksum: 6cd17d1578c8e4907ddf123e9bee21c9 (MD5) Previous issue date: 2002 / Mestrado / Saneamento e Ambiente / Mestre em Engenharia Civil
287

Obtenção, caracterização e aplicações de carvão ativado a partir de caroços de pêssegos

Oliveira, Miguel Pinto de 01 August 2008 (has links)
Made available in DSpace on 2014-08-20T13:42:05Z (GMT). No. of bitstreams: 1 Tese_Miguel_Pinto_de_Oliveira.pdf: 962671 bytes, checksum: 4149d63d44ce0a91f63fbaa9e92fe734 (MD5) Previous issue date: 2008-08-01 / Carvões ativados são muito utilizados no tratamento de águas, no processo de refino de açúcar, na clarificação de efluentes, na purificação de ar, etc. Seu poder adsortivo está associado às características texturais como área superficial, volume e área de microporos. Neste trabalho elaborou-se carvão ativado a partir de caroços de pêssego, que atualmente são descartados no meio ambiente. Avaliou-se o rendimento, densidade, índice de fenol, número de iodo e propriedades texturais em função da temperatura de carbonização dos carvões ativados. Observou-se que a 700°C, na concentração do agente ativador ZnCl2 de 6 mol L-1, e tempo de impregnação de 3 horas, obteve-se um índice de iodo médio de 988 mg de I2 g-1, valor superior aos carvões ativados comercializados no Brasil. Portanto, conclui-se que os caroços de pêssegos podem ser utilizados como precursores para a produção de carvão ativado. / Carvões ativados são muito utilizados no tratamento de águas, no processo de refino de açúcar, na clarificação de efluentes, na purificação de ar, etc. Seu poder adsortivo está associado às características texturais como área superficial, volume e área de microporos. Neste trabalho elaborou-se carvão ativado a partir de caroços de pêssego, que atualmente são descartados no meio ambiente. Avaliou-se o rendimento, densidade, índice de fenol, número de iodo e propriedades texturais em função da temperatura de carbonização dos carvões ativados. Observou-se que a 700°C, na concentração do agente ativador ZnCl2 de 6 mol L-1, e tempo de impregnação de 3 horas, obteve-se um índice de iodo médio de 988 mg de I2 g-1, valor superior aos carvões ativados comercializados no Brasil. Portanto, conclui-se que os caroços de pêssegos podem ser utilizados como precursores para a produção de carvão ativado.
288

OBTENÇÃO DE CARVÃO ATIVADO IMPREGNADO COM PRATA PARA FINS BACTERICIDAS / OBTAINING ACTIVATED CARBON IMPREGNATED WITH SILVER FOR BACTERICIDAL PURPOSES

Ribeiro, Gabrielly Vieira 09 October 2014 (has links)
Fundação de Amparo a Pesquisa no Estado do Rio Grande do Sul / The development of products with antimicrobial, inhibitory or even lethal action has attracted considerable attention in widely different research and applications fields. The present work studies the obtaining of an antimicrobial material derived from activated carbon submitted to adsorption in a medium with silver ions. It s divided into five chapters, dealing respectively of: introduction (subject s delimitation; research objectives; study s structure); literature review (antimicrobial materials, metal ions, activated carbon impregnated with silver (ACIS); ACIS s details of obtaining and applications); materials and methods (type of research, experiments, characterization tests); results and discussions and conclusions. To characterize the material obtained, in addition to the surface area analysis, inhibitory and bactericidal effects of the samples were evaluated by microbiological testing with different bacteria. About the experimental methodology, it was tested the effects of the silver ions impregnated on coal in cultures of bacteria Escherichia coli and Staphylococcus aureus from different strains. These effects were evaluated by minimum inhibitory concentration and minimum bactericidal concentration tests. The results for the material obtained confirmed the action of silver as an important antibacterial agent. / O desenvolvimento de produtos com ação antimicrobiana, inibitória ou mesmo letal, tem atraído considerável atenção nos mais distintos campos de pesquisa e aplicações. O objetivo deste estudo foi obter um material antimicrobiano a partir de carvão ativado submetido à adsorção em um meio com íons de prata. O trabalho está dividido em cinco capítulos, tratando respectivamente de: introdução (delimitação do tema; objetivos da pesquisa; estrutura do estudo); fundamentação teórica (materiais antimicrobianos; íons metálicos; carvão ativado impregnado com prata (CAIP); detalhes de obtenção e aplicações do CAIP); materiais e métodos (tipo de pesquisa; experimentos; testes de caracterização); resultados e discussões e considerações finais da autora. Para a caracterização do material obtido, além de análise de área superficial, avaliaram-se os efeitos inibitório e bactericida das amostras através de testes microbiológicos com diferentes bactérias. Quanto à metodologia experimental aplicada, foram testados os efeitos da presença de íons de prata no carvão em culturas de bactérias Escherichia coli e Staphylococcus aureus de diferentes cepas. Tais efeitos foram avaliados através de testes de concentração mínima inibitória e concentração mínima bactericida. Os resultados referentes ao material obtido confirmaram a ação da prata como um importante agente antibacteriano.
289

Remoção de bisfenol A de águas contaminadas através de processos de separação por membranas e de sorção

Dal Magro, Renata January 2013 (has links)
Os desreguladores endócrinos, como o bisfenol A (BPA), são compostos encontrados na água em concentrações da ordem de μg.L-1 ou ng.L-1, sendo por isso também denominados micropoluentes. Sua presença, mesmo em baixas concentrações, pode causar prejuízos aos organismos expostos. Neste contexto, o objetivo do presente trabalho foi avaliar a remoção de BPA por membranas de ultrafiltração (UF) e osmose inversa (OI) e por carvão ativado granular (CAG). Essas técnicas têm a vantagem de não gerar subprodutos que também podem ser tóxicos. Nos estudos foram realizados experimentos para remoção do BPA através de membrana PL-1 (celulose regenerada de 1 kDa), Sy-10 (polietersulfona de 10 kDa) e membrana de OI (poliamida) reutilizada, com concentração inicial de 500 μg.L-1 de BPA. Para a membrana Sy-10, foram testados os pHs 7 e 10. Os ensaios de adsorção foram realizados com CAG (1-2mm) em frascos contendo 100 mL da solução de BPA, com 0,5 g de CAG para cada frasco. As variáveis testadas foram pH, tempo de contato e concentração inicial na ordem de mg.L-1. Adicionalmente, foi testada a concentração inicial de 500 μg.L-1 de BPA em experimento de adsorção. Os resultados obtidos mostraram que a capacidade da membrana Sy-10 para remoção de BPA foi superior, chegando a cerca de 90% de remoção, em contraposição aos 20% encontrados para PL-1. A membrana de OI apresentou remoções de cerca de 95%. A influência do pH (7 e 10) na remoção do BPA para a membrana Sy-10 não mostrou-se significativa. Nos ensaios de adsorção, analisando diferentes valores de pH, obteve-se eficiência de 93% para pH 7. Ensaios de variação do tempo de contato com CAG mostraram que o equilíbrio é atingido nos primeiros 10 minutos para a maior concentração e em 40 minutos para a menor concentração testada, de 500 μg.L-1. O estudo do efeito da concentração inicial de BPA na adsorção mostrou que a remoção aumenta com o aumento da concentração inicial do poluente. Conclui-se que tanto a adsorção em CAG quanto membranas são boas alternativas para a remoção de BPA de soluções aquosas. As duas técnicas poderiam ser usadas conjuntamente, sendo que o concentrado do processo com membranas poderia ser submetido à adsorção por CAG. / Endocrine disrupting chemicals, such as bisphenol A (BPA) compounds, are found in water at concentrations of the order of μg.L-1 or ng.L-1 is therefore also known micropollutants. His presence, even at low concentrations, can cause damage to exposed organisms. In this context, the aim of this study was to evaluate the removal of BPA by ultrafiltration (UF) and reverse osmosis (RO) membranes and granular activated carbon (GAC). These techniques have the advantage of not generating by-products can also be toxic. In the studies were performed experiments to remove the BPA by PL-1 (1 kDa regenerated cellulose), Sy-10 (10 kDa polyethersulfone) and RO (polyamide) reused membranes, with initial concentration of 500 μg.L-1 of BPA. For Sy-10 membrane pHs 7 and 10 were tested. The adsorption experiments were carried out with GAC (1-2mm) in flasks containing 100 mL of the BPA solution and 0.5 g of GAC to each vial. The variables tested were pH, contact time and initial concentration on the order of mg.L-1. Additionally, we tested the initial concentration of 500 μg.L-1 of BPA in adsorption experiment. Results showed that the capacity of Sy-10 membrane to remove BPA was higher, reaching approximately 90% removal, as opposed to the 20% found to PL-1. The RO membrane showed removal of about 95%. The influence of pH (7 and 10 ) in the removal of BPA onto the membrane Sy - 10 was not significant. In adsorption tests, analyzing different pH values was obtained efficiency from 93% to pH 7. Testing time variation of contact GAC showed that equilibrium is reached in the first 10 minutes to the largest concentration and 40 minutes to the lowest concentration tested, 500 μg.L-1. The study of the effect of the initial concentration of BPA in the adsorption showed that removal increases with increase in the initial concentration of the pollutant. It was concluded that both the GAC adsorption as membranes are good alternatives for the removal of the BPA aqueous solutions. The two techniques could be used together, with the concentrate from the membrane process could be subjected to adsorption GAC.
290

Reuso de agua de processo industrial : uma proposta para o setor textil

Cantelli, Dirceu Luchesi 25 February 1999 (has links)
Orientador: Ruben Bresaola Junior / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil / Made available in DSpace on 2018-08-03T14:45:25Z (GMT). No. of bitstreams: 1 Cantelli_DirceuLuchesi_M.pdf: 6646445 bytes, checksum: c6d29696ea49a97f4510467190ae5b6e (MD5) Previous issue date: 1999 / Resumo: O presente trabalho descreve diversos setores de uma indústria têxtil, visando dar melhor compreensão de como são gerados seus despejos líquidos. Apresenta resultados de tratamento biológico seguido de físico-químico, desse tipo de indústria, com a indicação da qualidade obtida para os efluentes parciais e finais. O sistema biológico pelo processo de lodos ativados por batelada é utilizado como parte primeira da tratabilidade dos despejos líquidos, desenvolvida pelo reator biológico em escala piloto, tendo sido obtidos resultados da ordem de 98% de remoção de DBO. O sistema físico-químico, pelo processo de coagulação - floculação, foi utilizado para tratar o efluente clarificado do tratamento biológico. Os resultados obtidos através das amostras submetidas a esse procedimento. para os parâmetros Cor, Turbidez, Dureza, Fe e Mn, mostraram ser possível obter um efluente dentro dos limites estabelecidos pela EPA (1974), para água de processo. Foram realizados testes de tingimento com as amostras do clarificado do tratamento fisico-químico, após filtração em papel whatman 40 e pôde ser verificado que a qualidade-final do material testado, não teve qualquer distinção em relação ao outro material tingido, usando água de processo utilizada normalmente. Esses dados indicam a possibilidade de reuso e I ou reciclagem, após filtração acrescida ao processo de coagulação, floculação e decantação. Outrossim, os resultados deste trabalho podem indicar para este tipo de indústria, que os referidos limites possam ser até mesmo revistos / Abstract: The present work describes several sections of a textile industry, seeking to give better understanding of as they are generated its wastewater. It presents results of biological treatment followed by physical-chemist system, of that industry type, with the indication of the quality obtained for the partial and final effluents. The biological system for the sequencing bath reacors is used as first part of the treatment of the wastewater, developed by the biological reactor in pilot scale, having been obtained results of the order of 98% of removal of DBO. The physical-chemical system, for the coagulation- flocculation process, was used to treat the clarified effluent of the biological treatment. The results obtained through the samples submitted to that procedure, for the parameters Color, Turbidity, Hardness, Fe and Mn, showed to be possible to obtain an effluent within the limits of having established for EPA (1974), for process water. Dyeing tests were accomplished with the samples of the clarified of the chemical-physical treatment, after filtration in paper whatman 40 and it could be verified that the final quality of the dyeing material, didn't have any distinction in relation to the other material dyeing, using process water normally used. Those data indicate the reuse and / or recycling possibility, after filtration adding to the studied process. Also, the results of this work can indicate for this industry type, that referred them limits can be even having reviewed. / Mestrado / Saneamento / Mestre em Engenharia Civil

Page generated in 0.1328 seconds