• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • 1
  • Tagged with
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

En jämförelsestudie mellan manuell, semiautomatisk och automatisk utlinjering av endokardiet vid bedömning av ejektionsfraktionen. / A comparative study between manual, s semiautomatic and automatic tracing of the endocardium the assessment of ejection fraction.

Petersson, Ida January 2020 (has links)
Introduktion: Vid ekokardiografi används ultraljudsvågor med frekvens över 20 000Hz. Ultraljudssändare med piezoelektriska kristaller används för att generera ljudvågor som skickas ut i kroppen, reflekteras och sedan återvänder till kristallerna för att skapa en ultraljudsbild. Ejektionsfraktionen uttrycker hur stor del av den diastoliska volymen som pumpas ut i kroppen under systole och är en viktig parameter vid bedömning av den globala systoliska funktionen. Den rekommenderade metoden Simpsons biplan jämförs med Philips automatiska funktion a2Dq, som utgår ifrån speckle tracking principen, för bedömning av ejektionsfraktionen. Material och metod: 32 hjärtfriska testpersoner mellan 20–43 år inkluderades i tvärsnittsstudien. Apikala 4- och 2-kammarbilder insamlades ifrån testpersonerna och användes för beräkning av ejektionsfraktionen. Den manuella metoden Simpsons biplan grundas på operatörens utlinjering av endokardiet. Den automatiska funktionen a2Dq utgår ifrån 53 hjärtmodeller och placerar en region of interest automatiskt. Den semiautomatiska funktionen används genom att operatören modifierar region of interest men inte längden av vänsterkammaren. Resultat: Resultatet visade att det inte förelåg någon signifikant skillnad i mätvärdena av ejektionsfraktionen mellan de tre mätprinciperna. Den semiautomatiska och manuella metoden som är operatörsberoende hade likvärdiga mätresultat. Den automatiska funktionen erhöll totalt 6 mätvärden som hamnade utanför normalgränserna. Diskussion: Automatiska funktioner för bedömning av ejektionsfraktionen utvecklas snabbt och kräver utvärderingar. Automatiska mätningar har påvisats vara fördelaktiga då de inte är så tidskrävande som den manuella Simsons biplanmetoden. Tidsaspekten framhävs i de flesta studier dock på bekostnad av säkra mätresultat. Observationerna i denna studie påvisar att den automatiska funktionen inte är säker nog för användning. Konklusion: Enligt observationer ifrån denna studien rekommenderas att den automatiska funktionen ifrån Philips inte används. / Introduction: Ultrasound are soundwaves with frequencies above 20 000Hz. Piezoelectric crystals are used to generate sound waves that can be transmitted into the tissue and reflected back to the crystals to obtain an ultrasound image. The ejection fraction expresses how much blood the left ventricle pumps out with each contraction and is an important parameter for assessment of the hearts global systolic function. The recommended method Simpson´s biplane to assess ejection fraction is compared with Philips automatic function a2Dq, which is based on the principle of speckle tracking. Material and method: The study population included 32 tests subjects with age between 20-43 years old. The test subjects had no records of earlier heart pathologies. Apical 4- and 2-chamber images were collected for the purpose to measure the ejection fraction. The manual method Simpson´s biplane is based on the sonographers manual tracking of the endocardial border. The automatic function a2Dq is based on 53 heart models with different anatomy and physiology and applies a region of interest automatically along the endocardial border. The semi-automatic function allows the sonographer to adjust the region of interest but not the length of the chamber. Result: The result showed that there was no significant difference in the measured values of ejection fraction between the three different techniques. The semi-automatic and Simpson´s biplane method showed equivalent results. The automatic function showed a wide variance of measurements which resulted with a total of 6 measurement ended up below the normal values for ejection fraction. Discussion: Automatic functions for assessing the ejection fraction rapidly develops and requires validations. Automatic functions have shown to be advantageous as the are not as time-consuming as the manual Simpson´s biplane method. In most studies, however, the time aspect is emphasized at the expense of correct measurements results. The observations in this study show that the automatically function a2Dq from Philips are not providing correct measurements. Conclusion: According to observations in this study, it´s recommended that the automatic function from Philips shouldn’t be used.
2

Obvody pro tvarování svazku antény v pásmu L / Beam Shaping Circuits for L Band Antenna

Kalina, Ladislav January 2017 (has links)
This thesis contains design of beamforming network designed for passive radar antennas. The first part contains theory of passive radars and beamforming networks. The next part implies design of beamforming network at the block digram level. Then are choosed circuits for amplitude and phase control, including the design of control communication. It follows by realization of IQ phase shifter and his automatic measurement. Based on this results is phase shifter adjusted and PCB of 2x2 beamforming network is designed. Last part includes design of control application (Matlab) and control program for STM32F407VG microcontroller.

Page generated in 0.1093 seconds