• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • 1
  • Tagged with
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Trycksatt avloppssystem och självfallssystem i Fredrikstad kommun. En jämförande fallstudie. / Pressure sewer system and gravity system in Fredrikstad municipality. A comparative case study.

Dahllöf, Karin January 2014 (has links)
Krav om förbättrad spillvattenrening och städer som förgrenar sig över större områden är några av anledningarna till att dagens avloppsledningsnät får allt längre ledningssträckor. Att med gravitationens hjälp föra avloppsvatten framåt kräver ett kontinuerligt fall som vid långa avstånd kan innebära mycket schaktning, den ekonomiskt mest belastande delen vid nyinstallation av avloppsledningsnät. Ett fördelaktigt alternativ kan vara trycksatt avloppssystem, som sedan 70-talet har kompletterat de traditionella självfallssystem i kuperade och bergiga områden. På senare tid har trycksatt avloppsystem fått större användningsområde utanför sina etablerade bruksområden med anledning av skärpta krav på rening och kostnadseffektivitet. Självfallssystem är dock det mest använda avloppssystemet i urbana områden. För ett bostadsområde i utkanten av centrum, utanför de båda systemens vedertagna användningsområden, vore det därför intressant att undersöka vilket av avloppssystemen som är bäst lämpat. För VA-branschen generellt vore det också intressant att utreda hur de båda systemen står sig vid en jämförelse. Med anledning av detta var syftet med examensarbetet att jämföra trycksatt avloppssystem med självfallssystem på grundval av ekonomi, miljö och kapacitet. I tillägg undersöktes om några generella slutsatser kunde fastställas utifrån fallstudien. Undersökningen baserades på ett bostadsområde i utkanten av Fredrikstad centrum, som nyligen projekterats med självfall. Ett teoretiskt trycksatt avloppssystem projekterades. Ekonomi värderades utifrån drift- och underhållskostnader samt grund- och reinvesteringskostnader. Kapaciteten jämfördes numeriskt och via dimensioneringsmodeller. Vad gäller den miljömässiga jämförelsen utvärderades systemet med hjälp av rapporter utgivna av Svenskt Vatten och Norsk Vann. Det planerades en utbyggnad för området till dubbla antalet fastigheter vilket visade sig bli avgörande för det ekonomiska resultatet. Den vitala faktorn var de höga investerings- och driftskostnaderna för pumpenheterna vilket gjorde självfallssystemet mer ekonomiskt lämpligt. Även ur ett miljömässigt perspektiv var självfallssystemet marginellt bättre, givet att riskeffekterna inte rankades inbördes. Kapacitetsmässigt dimensioneras självfallssystem för nästan det dubbla flödet jämfört med trycksatt system, vilket ger det trycksatta systemet en kapacitet mer anpassad till behovet. Generellt sett antydde resultatet att trycksatt system var mer gynnsamt vid glesare bebyggelse. / As a result of stricter treatment requirements and city expantion the length of the sewer network is steadily increasing. To drain wastewater by gravity requires a continuous slope which often results in great excavation - a very costly part in the process. An advantageous alternative could be a pressurized sewer system, which has been a useful complement to traditional gravity systems in hilly or rocky areas since the 70’s. Even though pressurized sewer systems lately have tended to be more frequently used outside their common application area due to stricter requirements on treatment and cost-efficiency, gravity systems are still the most common sewer system in urban areas. Concerning this, it would be intresting to investigate which of the two systems that suites a residental area on the outskirts of a city center best, since the area is outside the traditional usage of the two established systems. In addition it would be interesting for the wastewater industry in general to investigate how the two systems compare.  For this reason the aim of this master thesis was to compare pressure sewer systems with gravity systems on the basis of economy, environment and capacity. In addition, it was examined whether any general conclusions could be determined from the case study. The survey was based on a residental area in the outskirts of Fredrikstad city center, recently designed with a gravity system. A theoretical pressure sewer system was designed. Economy was evaluated based on the operating and maintenance costs and basic and reinvestment costs. The capacity was compared numerically and through design templates. As for the environmental comparison, an evaluation was done on the basis of reports from the Swedish Water & Wastewater Association and Norwegian Water BA. An expansion to double the number of real properties was planned for the area of study, which proved to be crucial to the financial results. The gravity system was most appropriate from an economic standpoint and the vital factor was the high investment and operating costs for the pumping units. Even from an environmental point of view, the gravity system was maginally better. Given that the risk effects are not ranked relative to each other. In terms of capacity the gravity system was dimensioned for almost twice the flow compared to the pressure sewer systems, which gave the pressure sewer system a more adusted capacity. The result indicated that the pressure sewer system is favorable in densely built flexible areas.
2

Moving towards a proactive sewer pipe inspection approach : A state-of-the-art analysis / På väg mot en proaktiv metod för inspektion av avloppsrör : En analys av den senaste tekniken

Mahamud, Ataul Hakim January 2023 (has links)
The failure of sewer pipes is a significant issue that can adversely affect the environment and public health. The problem is exacerbated by the additional burden it places on treatment plants, which must work harder to process the increased sewage flow resulting from pipe failures. The research in this thesis is based on an extensive review of the existing literature on sewer pipe failure and inspection, focusing on the proactive approach that can predict pipe failures to assist in effective maintenance. The study finds that several predictive models can accurately predict sewer deterioration with high accuracy (up to 95 % precision), making it possible to identify potential failures and address them before they cause significant damage or disruption. However, the research indicates that there has been relatively little work done on predicting blockage and CSO, two critical aspects of sewer pipe management that could be addressed more to manage sewer systems effectively. The thesis discusses that by developing an effective predictive model for prioritisation of monitoring sewer pipes, planners can save time and money on individual inspections while planning well ahead to avoid any service disruption. The study also summarised the data needs for the predictive models and found pipe age, material, diameter depth, and length to be the most commonly used input parameters by the existing model developers. The finding of this research can guide decision support in future efforts to improve sewer pipe inspection practices. / Fel på avloppsrör är en viktig fråga som kan påverka miljön och folkhälsan negativt. Problemet förvärras av den extra börda det innebär för reningsverken, som måste arbeta hårdare för att hantera det ökade avfallsflödet till följd av rörbrott. Forskningen i denna avhandling baseras på en omfattande genomgång av den befintliga litteraturen om fel på avloppsrör och inspektion, med fokus på det proaktiva tillvägagångssättet som kan förutsäga rörfel för att bidra till effektivt underhåll. Studien visar att flera prediktiva modeller kan förutsäga försämring av avlopp med hög noggrannhet (upp till 95 % precision), vilket gör det möjligt att identifiera potentiella fel och åtgärda dem innan de orsakar betydande skador eller störningar. Forskningen visar dock att det har gjorts relativt lite arbete för att förutsäga blockering och CSO, två kritiska aspekter av hantering av avloppsrör som skulle kunna hanteras mer för att hantera avloppssystemet effektivt. I avhandlingen diskuteras att genom att utveckla en effektiv prediktiv modell för prioritering av övervakning av avloppsrör kan planerare spara tid och pengar på enskilda inspektioner och samtidigt planera i god tid för att undvika eventuella driftstörningar. Studien sammanfattade även data behovet för de prediktiva modellerna och fann att röra ålder, material, diameter, djup och längd var de mest använda ingångs parametrarna av de befintliga modellutvecklare. Resultatet av denna forskning kan vägleda beslutsstöd i framtida ansträngningar för att förbättra praxis för inspektion av avloppsrör.

Page generated in 0.0231 seconds