Fusion d'images optique et radar à haute résolution pour la mise à jour de bases de données cartographiques / Fusion of high resolution optical and SAR images to update cartographic databases

Poulain, Vincent 22 October 2010 (has links)
Cette thèse se situe dans le cadre de l'interprétation d'images satellite à haute résolution, et concerne plus spécifiquement la mise à jour de bases de données cartographiques grâce à des images optique et radar à haute résolution. Cette étude présente une chaîne de traitement générique pour la création ou la mise à jour de bases de données représentant les routes ou les bâtiments en milieu urbain. En fonction des données disponibles, différents scénarios sont envisagés. Le traitement est effectué en deux étapes. D'abord nous cherchons les objets qui doivent être retirés de la base de données. La seconde étape consiste à rechercher dans les images de nouveaux objets à ajouter dans la base de données. Pour réaliser ces deux étapes, des descripteurs sont construits dans le but de caractériser les objets d'intérêt dans les images d'entrée. L'inclusion ou élimination des objets dans la base de données est basée sur un score obtenu après fusion des descripteurs dans le cadre de la théorie de Dempster-Shafer. Les résultats présentés dans cette thèse illustrent l'intérêt d'une fusion multi-capteurs. De plus l'intégration aisée de nouveaux descripteurs permet à la chaîne d'être améliorable et adaptable à d'autres objets. / This work takes place in the framework of high resolution remote sensing image analysis. It focuses on the issue of cartographic database creation or updating with optical and SAR images. The goal of this work is to build a generic processing chain to update or create a cartographic database representing roads and buildings in built-up areas. According to available data, various scenarios are foreseen. The proposed processing chain is composed of two steps. First, if a database is available, the presence of each database object is checked in the images. The second step consist of looking for new objects that should be included in the database. To determine if an object should be present in the updated database, relevant features are extracted from images in the neighborhood of the considered object. Those features are based on caracteristics of roads and buildings in SAR and optical images. The object removal/inclusion in the DB is based on a score obtained by the fusion of features in the framework of the Dempster-Shafer evidence theory. Results highlight the interest of multi sensor fusion. Moreover the chosen framework allows the easy integration of new features in the processing chain.
52

Apport de l’interférométrie radar (DinSAR et PSI) pour l’étude des effets de la sécheresse géotechniques : applications à l’Est de la région Île-de-France / Contribution of radar remote sensing (DINSAR and PSI) to the study of the drought effect on the topographic surface. Application to The East of the Île-de-France region. : application to the East of the Île-de-France region

Kaveh, Heydar 14 December 2010 (has links)
La sécheresse géotechnique est à l'origine de nombreux désordres urbains dans la régio n d'Ile-de-France. La présence d'argiles continentales Eocène-Oligocène aux propriétés gonflantes parmi les dépôts actuels les plus récents de la série géologique du Bassin Parisien entraîne, sous l'influence des contrastes climatiques liés à des évènements climatiques « extrêmes » (alternances sécheresse et période humide) des variations importantes du volume des sols. Les variations sont susceptibles d'induire des déplacements de la surface du sol qui affecte le bâti. Deux méthodes d'interférométrie radar y sont appliquées afin de suivre ces déplacements relatifs au cours du temps : si la méthode différentielle (DINSAR), qui permet de mesurer les déplacements de la surface du sol à partir de deux images radar acquises à des dates différentes se révèle peu performante sur l'Est du Bassin de Paris devant la faible cohérence de l'habitat pavillonnaire individuel, la seconde méthode, la technique de suivi des réflecteurs permanents, appelé Persistant Scatterer Interferometry ( PSI) permet de décrire précisément dans le temps les déplacements absolus de points à forte rétrodiffusion radar par la localisation, la caractérisation et la quantification des déplacements de la surface du sol à partir d'un grand nombre d'images radar à ouverture de synthèse (RSO). Des déformations liées au RGA observées sur les profils de pavillons sinistrés ont été mise en évidence et corrélé avec les périodes de sécheresse. Cette méthode présente un fort potentiel pour l'étude du risque naturel sécheresse géotechnique tout particulièrement sur l'Est du Bassin de Paris affecté lors des dernières périodes de sécheresses dans un contexte de changement climatique mondiale / Swelling soils may induce, under various climatic conditions such as drought or humid periods, surface displacements that affect small houses and buildings. The aim of this PhD work is to monitor through new interferometric methods those small displacements. Radar differential interferometry (DINSAR) method which enables one to map surface displacements from two radar images acquired on a specific area gives poor results in the east of the Paris Basin highly affected by the dryness hazards. It contrasts with Persistent Scatterer Interferometry (PSI) revealing precisely the seasonal behaviour of the displacements above swelling soils from a huge amount of radar images. Dryness events are correlated with swellings soils effects on damaged buildings thanks to the PSI profiles interpretation. This new application presents high potential to better understand the geologic processes and the natural hazard induced by swelling soils
53

Étude de l'aide à la décision par optimisation multicritère des programmes de réhabilitation énergétique séquentielle des bâtiments existants / Study of decision aiding through multi criteria optimization for existing buildings holistic energy retrofit

Rivallain, Mathieu 21 January 2013 (has links)
Sous nos latitudes, l’usage des bâtiments existants et les consommations énergétiques associées (chauffage, climatisation, ventilation, eau chaude sanitaire, éclairage et autres usages) sont responsables d’impacts considérables sur l’Environnement. De plus, le renouvellement du parc existant étant inférieur à 1% par an, dans la plupart des pays développés, la réhabilitation des bâtiments constitue un levier majeur de réduction des consommations d’énergie et des émissions de gaz à effet de serre. Cependant, l’identification de stratégies optimales de réhabilitation énergétique, incluant la planification des actions dans le temps, demeure une problématique complexe pour les acteurs de la Construction. Ces travaux de thèse visent à produire des connaissances afin de contribuer à l’aide à la décision pour l’identification de programmes efficaces de réhabilitation énergétique, à partir de méthodes d’optimisation multicritères. Les solutions (programmes séquentiels de réhabilitation énergétique) sont optimisées en termes de composition et de phasage. La composition est définie par la combinaison de mesures de réhabilitation mise en oeuvre. Celles-ci concernent l’enveloppe des bâtiments (isolation thermique, remplacement des fenêtres, surfaces de fenêtres) et le remplacement des équipements de chauffage, ventilation et production d’ECS. Pour chacune des mesures, plusieurs alternatives sont envisagées. Le phasage correspond à la permutation de ces mesures, définissant la séquence de mise en oeuvre. Les solutions sont évaluées sur une base multicritère et sur le cycle de vie. Les fonctions objectifs ciblent les impacts environnementaux de l’ACV (Analyse de Cycle de Vie), des indicateurs économiques, le bien-être des occupants par le confort thermique adaptatif en été. Des modèles d’ACV et d’analyse du coût du cycle de vie, utilisant la simulation thermique dynamique pour le calcul des besoins de chauffage et des températures intérieures, ont été développés pour l’évaluation des performances des solutions. Etant donnée la nature mathématique du problème (multicritère, combinatoire, à variables discrètes et à fonctions objectifs implicites non-linéaires), deux méthodes d’optimisation multicritères sont étudiées : les algorithmes génétiques (NSGA II) et la programmation dynamique. Dans l’approche génétique, la modélisation des solutions, sous la forme d’un couple de chromosomes, permet d’identifier des programmes séquentiels efficaces de réhabilitation énergétique et d’analyser les surfaces de compromis, en termes de définition et performances des solutions, de compromis entre les critères de décision. A partir de la représentation du problème par un graphe séquentiel, la programmation dynamique permet alors de comparer les solutions approchées issues de l’algorithme génétique, ou d’approches court-termistes, au front de Pareto exact. L’optimisation exacte a également été exploitée pour analyser la sensibilité des solutions à différents paramètres de modélisation dont le comportement des occupants, l’évolution des prix de l’énergie, la durée de vie des composants de réhabilitation. Les contraintes budgétaires s’appliquant au projet de réhabilitation ont été ensuite intégrées dans un algorithme génétique multicritère sous contraintes, adapté à l’étude des stratégies de réhabilitation sous la contrainte d’un plan de financement. Enfin, l’approche génétique a été étendue depuis l’échelle du bâtiment à celle du par cet l’optimisation exacte a été utilisée pour caractériser les typologies de bâtiment en réhabilitation. L’intérêt des différentes méthodes est illustré sur une étude de cas (…) / Under our latitudes, existing buildings energy consumptions, related to heating, cooling, ventilation, domestic hot water (DHW), lighting and other uses, are responsible for significant environmental burdens. Moreover, existing buildings annual replacement rate being lower than 1%, in most developed countries, existing stock retrofit represents a major lever to reach commitments on climate change and non-renewable energy consumption mitigation. However, the identification of optimal sustainable retrofit programs, including actions planning over a time period, is still a difficult task for professionals.This thesis aims at producing knowledge in order to contribute to decision support for efficient energy retrofit programs identification, through the application of different multi-criteria optimization techniques. The solutions (sequential building energy retrofit programs) are optimized both on their content and planning. The content refers to the combination of retrofit measures considered. These address holistically building envelopes (thermal insulation, windows replacement, window to wall ratios), and the replacement of equipment for ventilation, heating and DHW production. For each of these measures, various options are considered. The planning corresponds to the permutation of these measures, defining a time sequence for implementation. The solutions are evaluated on a multi-criteria and life cycle basis. The objective functions considered target environmental impacts evaluated using LCA (Life Cycle Assessment), some financial indicators and occupants' well-being through thermal comfort in summer. Life cycle assessment and life cycle cost models, using building dynamic thermal simulation for heating load and thermal comfort evaluation, are implemented to assess solutions performances.Considering the problem mathematical nature (multi-criteria, combinatorial, discrete variables, implicit non-linear objective functions), two suitable multi-criteria optimization techniques have been studied: multi-criteria genetic algorithm (NSGA-II) and dynamic programming. In the genetic approach, the modelling of each solution by a pair of chromosomes allowed to identify efficient sequential energy retrofit programs and analyse Pareto compromise surfaces, in terms of solutions features, performances and relationships in between criteria. Then, the representation of the problem on a sequential graph enabled us to apply dynamic programming, to compare both the genetic approximate solutions, and the results of some short- term approaches to the exact Pareto frontier. The search for exact solutions also been exploited to perform sensitivity analysis on different modelling parameters such as heating temperature setting, energy prices evolution or materials lifespan. Real life budget constraints have been incorporated to build a constrained multi-criteria genetic optimisation method, suitable to study retrofit strategies under financing plans. At the end, the genetic approach has been extended from building scale to stock scale and exact optimization has been used to characterize building types in terms of energy retrofit.The benefits of these methods have been illustrated on case studies. Knowledge has been produced in terms of multi criteria optimization methodology, applied to sequential energy retrofit, and understanding of building stocks evolution. These developments contribute to decision aiding; providing decision makers with efficient energy retrofit strategies and a description of the comprise surface, at the building or building stock scale, on a multi- criteria basis, over life cycle
54

Le château de Choisy-le-Roi au XVIIIe siècle : architecture, vie sociale, administration / The castel of Choisy-le-Roi in the 18th century : architecture, sociability, administration

Bornet, Anaïs 05 January 2019 (has links)
Aujourd’hui disparu, le château de Choisy-le-Roi reste bien souvent dans les esprits un symbole des fantaisies coûteuses de Louis XV et de Mme de Pompadour, idée répandues par la littérature et les chroniques des XVIIIe et XIXe siècles. Choisy occupe cependant une place majeure dans l’histoire de l’architecture des programmes mis en place pour les besoins de la vie de cour de la deuxième moitié du XVIIIe siècle. Proche de la forêt de Sénart, le château devient d’abord une résidence conviviale où se retrouve, après les parties de chasse, une « cour particulière », composée des familiers du roi et de la favorite. Louis XV convie par la suite à Choisy ses enfants, auxquels il consacre de courts séjours dans un cadre moins protocolaire. La suite nombreuse attachée à leur service transforme cet espace auparavant « privé », et le rend plus accessible aux courtisans. Cette augmentation de la fréquentation entraîne de nombreux travaux dirigés par l’architecte Ange-Jacques Gabriel. En conséquence de cette perte d’ « intimité », d’autres lieux particuliers sont alors aménagés ; ainsi, le Petit-Château, premier pavillon d’habitation de Louis XV, est construit. C’est là où prend place la table « volante ». À travers l’étude du domaine royal, on perçoit également le fonctionnement quotidien du château, où vivent de nombreux employés attachés à l’administration des Bâtiments du roi. Le travail sur le terrain est coordonné par un contrôleur des Bâtiments, dont les lettres échangées avec le Directeur de l’administration délivrent de précieuses informations sur la gestion et le personnel. Ainsi, le château de Choisy apparaît comme une pièce majeure pour la compréhension de la cour et de la sociabilité de Louis XV. / Today disappeared, the castel of Choisy-le-Roi remains as a symbol of the Louis XV and Mme de Pompadour’s expensive whims, idea spread by the 18th and 19th centuries literature. However, Choisy has an important part in the history of the programs architecture set up for the needs for the life of court of the second half of the 18th century. Close to the forest of Sénart, the castel becomes at first a friendly residence where finds itself, after the hunting trips, a " particular court ", made up of the king ’s close friends. Louis XV invites later to Choisy his children, to whom he dedicates short stays in a informal settings. The numerous entourage attached to their service transforms this space previously "private", and makes it more accessible to the courtiers. This increase of the company produces many construction works by the architect Ange-Jacques Gabriel. As a result of this loss of "intimacy", other intimate places are then fitted out; so, the Petit-Château, the first detached house of Louis XV, is built. It is where takes place the table « volante ». Through the study of the royal domain, we also notice the daily functioning of the castel, where live numerous employees attached to the administration des Bâtiments du roi. The field works is coordinated by a controller des Bâtiments, from whom letters exchanged with the Director of the administration give valued informations on management and staff. So, the castel of Choisy appears as a major part for the understanding of the court and the sociability of Louis XV.
55

Modélisation et commande hiérarchisées du bâtiment pour l'amélioration des performances énergétiques, thermiques et optiques / Hierarchical modeling and control of buildings for enhanced energetical, thermal and optical performances

Arnal, Etienne 11 January 2013 (has links)
A notre époque, la maîtrise des consommations énergétiques est un enjeu très important pour la préservation des ressources naturelles terrestres. Outre le domaine des transports, des gains énergétiques significatifs existent dans le domaine des bâtiments résidentiels ou tertiaires. Alors que la construction basse consommation est aujourd'hui une réalité, la rénovation n'est que très rarement mise en pratique. Ainsi, l'objectif de cette thèse est d'évaluer les gains énergétiques potentiels issus de la rénovation d'un bâtiment ancien pour être en cohérence avec son environnement et ses modes d'exploitation. Au coeur de ce travail se trouvent les problématiques du système bâtiment, et du confort des occupants. Au regard de ces connaissances, nous proposons une architecture globale de contrôle du bâtiment répondant à des missions de confort optique et thermique, et de réduction des consommations énergétiques. Pour cela nous nous appuyons sur l'approche systémique et l'Automatique qui permettent depuis la modélisation jusqu'à l'élaboration de lois de commande de faire coopérer toutes les installations domotiques. L'évaluation du contrôle est réalisée en simulation sur un bâtiment ancien équipé d'un chauffage central, de luminaires et de stores vénitiens intérieurs pilotés. L'architecture de contrôle présentée est issue d'une analyse systémique du bâtiment et se base sur une approche hiérarchique en adéquation avec les exigences des utilisateurs et les différentes échelles de représentation. Afin d'expérimenter cette architecture de contrôle, un modèle physique de bâtiment multi-échelle a été réalisé en utilisant une approche Bond-Graph et permet d'estimer le comportement optique et thermique du bâtiment en séparant les dynamiques lentes et rapides. La synthèse des lois de commande a ensuite été effectuée en réduisant ce modèle de simulation et a permis d'implémenter deux lois de commandes. La première s'exprime à l'échelle du bâtiment par une commande prédictive du chauffage central et considère l'évolution future de la température extérieure et de la puissance radiative solaire. La seconde prend place au niveau des pièces sous la forme d'une commande optimale des radiateurs, des stores et des luminaires afin d'assurer la température opérative moyenne et l'éclairement moyen souhaité par les occupants. L'étude des gains énergétiques offerts par la rénovation du système de contrôle a permis de mettre en valeur l'intérêt de l’architecture de contrôle présenté. Les résultats ont montré que l'implantation d'une commande prédictive sur le chauffage central permet de réduire de plus de 20% ses consommations énergétiques. Par ailleurs, le contrôle optimal dans les pièces offre un gain d'environ 20% sur le confort thermique et de 75% sur le confort optique. / Today, the control of energy consumption is a very important issue for the preservation of the natural resources. Besides transportation domain, substancial energetic gains exist in residential and office buildings. While low energy building is now a reality, the renovation is rarely put into practice. The objective of this thesis is to evaluate the potential energy savings resulting from the renovation of old buildings. In the core of this work are the problematics of the building system and of the household comfort. Based on this knowledge, we propose here a global control architecture of the building, which accomodates thermal and optical confort, and reduction of energy consumption. Specifically, we focus on automatic control and systemic approach, which enable, from modelling to control law synthesis, a global cooperation of all home automation equipments. Our approach is to design a hierarchical control architecture and simulate it in the case of an old building with central heating, lighting and interior Venetian blinds. The control architecture is designed from a systemic analysis of buildings. It is based on a hierarchical approach in order to adapt to user requirements and to different scales of spatial representation (from the building to the room). To experiment this control architecture, a physical multi-scale model of building was developed using a Bond-Graph approach. This model allows to estimate the optical and thermal behavior of the building separating the slow dynamics of the fast ones. The synthesis of actuators control laws was then performed after reducing the simulation model. It helped to implement two control laws : The first is expressed throughout the building by a predictive control of central heating system and considers the future behaviour of the outdoor temperature and solar radiative power. The second takes place at the rooms level as an optimal control of radiators, Venetian blinds and lighting to ensure the operative temperature and illumination desired by the occupants. The study of energy savings offered by the renovation of the control system helped to highlight the interest of the presented control architecture. The results showed that the implementation of predictive control on the central heating leads to reduce more than 20% of the energy consumption. Moreover, the optimal control in rooms increase thermal comfort around 20% and the visual comfort by 75%.
56

L’architecture théâtrale en France de la Révolution au Second Empire : théorie, innovation, réglementation, réalisations / Theatre architecture in France from French Revolution to Second Empire : theory, innovation, legislation, construction

Casas correa, Maribel 16 December 2017 (has links)
L’architecture théâtrale en France de la Révolution au Second Empire :théorie, innovation, réglementation, réalisationsA l’avènement de la Révolution, la France connait en termes d’architecture théâtrale une période particulièrement foisonnante. L’impulsion donnée sous Louis XV au théâtre porte ses fruits et la société manifeste pendant les dernières décennies du XVIIIe siècle, et ce malgré l’opposition de l’église, un engouement prononcé pour le spectacle, appelé plus tard théâtromanie. Tout au long du XIXe siècle, le théâtre occupe une place privilégiée dans la vie culturelle et sociale de la France. L’édifice théâtral sert alors à cristalliser les aspirations des différents publics qui le fréquentent et fait l’objet de multiples réflexions, aussi bien du point de vue théorique que dans le domaine de l’innovation. Etant parmi les rares bâtiments civils à accueillir un public aussi nombreux et diversifié, il devient également un lieu privilégié d’expérimentation, en termes de salubrité et de systèmes techniques.Les nuisances qui accompagnent son implantation dans la ville et les multiples incendies qui détruisent différents théâtres à travers l’Europe conduisent aux instances au pouvoir à réglementer, de plus en plus, le fonctionnement des théâtres jusqu’à émettre des préconisations qui ont à trait à la configuration même de son cadre bâti.Ainsi, l’architecture théâtrale de la première moitié du XIXe siècle revêt plusieurs facettes qu’il était nécessaire d’explorer afin de comprendre ce qui contribue à modeler l’image du théâtre « à la française » dont l’Opéra de Paris devient le plus haut représentant en France comme à l’international. / Theatre architecture in France fromFrench Revolution to Second Empiretheory, innovation, legislation, constructionAt the dawn of the Revolution, a vague of theatrical constructions embraces France. The impulse which had been given under Louis XV to theatres bear now fruit. Furthermore, despite the opposition of the Church, the French society expresses a real enthusiasm for spectacles that one will later call “theatremania”. During the whole nineteenth century, theatres occupy a privileged position in the cultural and social life in France. The theatrical buildings contribute to crystallize the ambitions of the attended public. By consequence, theatres are an object of thinking, weather it is on the level of architectural theory, or on the level of innovation. Representing a typology of public buildings which host a very numerous and a very diversified public, the theatre becomes a privileged space of experimentation, in terms of public health as well as in terms of techniques. The noise pollution which accompanies its integration within the city, and the numerous fires that destroy a lot of theatres across Europe, lead the public administration to regulate more and more the functioning of theatres, to a point that these new regulations have an enormous impact on the architectural development of theatres.In this context, the theatrical architecture of the first half of nineteenth century takes several aspects which this work explores in order to illuminate the rise of the so-called theatre « à la française », of which Garnier’s Opéra de Paris will become the most prominent example.
57

Outils numériques pour la reconstruction et l'analyse sémantique de représentations graphiques de bâtiments / Digital tools for reconstruction and semantic analysis of graphical representations of buildings

Gimenez, Lucile 10 December 2015 (has links)
De nombreux bâtiments anciens sont à rénover pour diminuer leur consommation énergétique. Grâce à l'émergence d’outils numériques tels que la maquette numérique d'un bâtiment ou BIM (Building Information Modeling), des simulations énergétiques peuvent être réalisées. Or, pour la plupart des bâtiments, aucune information numérique n'est disponible. L'objectif de nos travaux est de développer une méthodologie pour générer des maquettes numériques de bâtiments existants à faible coût en limitant l'acquisition de données. Notre choix s'est porté sur l'utilisation de plan papier 2D scanné. Nous faisons l'hypothèse qu'un tel plan est presque toujours disponible pour un bâtiment même s’il n'est pas toujours à jour et que sa qualité influe sur celle de la reconstruction. La reconstruction automatique d'un BIM à partir d'une image se base sur la recherche et l'identification de 3 composantes: la géométrie (forme des éléments), la topologie (liens entre les éléments) et la sémantique (caractéristiques des éléments). Lors de cette phase, des ambiguïtés peuvent apparaître. Nous proposons un processus basé sur des interventions ponctuelles et guidées de l'utilisateur afin d'identifier les erreurs et proposer des choix de correction pour éviter leur propagation.Nous présentons la méthodologie développée pour proposer une reconstruction semi-automatique et une analyse des résultats obtenus sur une base de 90 plans. Les travaux ont ensuite porté sur une généralisation du processus afin d'en tester la robustesse, le passage à l'échelle et la gestion multi-niveaux. Le processus développé est flexible pour permettre l’ajout d'autres sources de données pour enrichir la maquette numérique. / Many buildings have to undergo major renovation to comply with regulations and environmental challenges. The BIM (Building Information Modeling) helps designers to make better-informed decisions, and results in more optimal energy-efficient designs. Such advanced design approaches require 3D digital models. However such models are not available for existing buildings. The aim of our work is to develop a method to generate 3D building models from existing buildings at low cost and in a reasonable time. We have chosen to work with 2D scanned plans. We assume that it is possible to find a paper plan for most buildings even if it is not always up-to-date and if the recognition quality is also dependent to the plan. The automatic reconstruction of a BIM from a paper plan is based on the extraction and identification of 3 main components: geometry (element shape), topology (links between elements) and semantics (object properties). During this process, some errors are generated which cannot be automatically corrected. This is why, we propose a novel approach based on punctual and guided human interventions to automatically identify and propose correction choices to the user to avoid error propagation.We describe the developed methodology to convert semi-automatically a 2D scanned plan into a BIM. A result analysis is done on 90 images. The following works is focused on the process genericity to test its robustness, the challenge of moving to scale and the multi-level management. The results highlight the pertinence of the error classification, identification and choices made to the user. The process is flexible in order to be completed by others data sources.
58

Vers une nouvelle méthodologie de conception des bâtiments, basée sur leurs performances bioclimatiques / Toward a new method of buidling design, based on bioclimatic performances

Chesné, Lou 18 October 2012 (has links)
Les règles et usages actuels de conception des bâtiments sont essentiellement basés sur la minimisation des déperditions thermiques, ce qui se traduit par la prédominance de l’isolation thermique comme solution d’enveloppe. Or cette logique n'est pas nécessairement la plus pertinente car des ressources énergétiques existent dans l'environnement, et leur apport mériterait d'être pris en considération. Certaines technologies bioclimatiques, et surtout solaires, existent déjà mais leur utilisation n'est pas du tout généralisée à cause d'un manque de repère sur leurs performances. Pour considérer la démarche bioclimatique, il est nécessaire de pouvoir évaluer à la fois la "qualité énergétique" de l'environnement, et l'aptitude des bâtiments à exploiter cet environnement. La méthodologie présentée dans cette thèse est basée sur le calcul d'indicateurs de performance bioclimatique issus de simulations numériques de bâtiments dans diverses conditions climatiques. La simulation permet de supprimer facilement une ressource pour pouvoir obtenir les besoins d'un bâtiment non impacté par la ressource. Ces besoins peuvent alors être comparés à chaque instant au potentiel de la ressource afin de déterminer un potentiel utile, valorisable par le bâtiment. Il est également possible de comparer les besoins du bâtiment dans la simulation sans et avec la ressource et d'en déduire la quantité d'énergie provenant de la ressource réellement utilisée par le bâtiment pour couvrir ses besoins. Un jeu d'indicateurs est ainsi défini pour toutes les ressources et tous les besoins d'un bâtiment, et adapté plus particulièrement aux besoins de confort thermique (chauffage et rafraîchissement) et à trois ressources de l'environnement (le soleil, la voûte céleste et l'air extérieur). Un cas d'étude est alors choisi pour appliquer cette méthode et les résultats sont analysés à l'échelle du bâtiment tout entier ainsi qu'à l'échelle de chaque paroi. Une première analyse globale, sur toute l'année, permet de fixer des points de repères sur l'état des ressources et l'exploitation qui en est faite par les bâtiments. Dans un second temps, les résultats instantanés sont analysés de manière dynamique, et montrent que ces nouveaux indicateurs permettent de bien caractériser le comportement d'un bâtiment dans son environnement. Enfin, les indicateurs sont utilisés dans une approche de conception des bâtiments, et plusieurs pistes sont explorées. Une étude paramétrique est tout d'abord menée et permet d'observer l'influence du niveau d'isolation sur les indicateurs de potentiel et de performance. Puis ces indicateurs sont utilisés pour évaluer la performance bioclimatique de solutions d'enveloppe solaires. Dans un troisième temps, une optimisation de l'enveloppe est menée selon deux critères : un critère classique de minimisation du besoin, mais également un critère bioclimatique de maximisation de l'exploitation du potentiel solaire. / With the current issues concerning the potential savings in the building sector, reducing building energy consumption is a key point. Up to now, efforts have been focused on insulation to separate the inner ambiance from the fluctuation of the outside air temperature. However, insulating a building from its environment deprives it from the renewable free energy sources which exchange with the envelope, either they are heating or cooling sources. Using the building envelope to exploit these resources is the very principle of the bioclimatic architecture. But bioclimatic systems have never been evaluated regarding the amount of available energy they could use, partly because the energy exchanges between the resources and the building have never been really qualified regarding to the building needs, neither quantified in terms of available energy capacity to meet these needs. The aim of this thesis is thus to propose a method to assess both: - the capacity of the environmental resources to cover the building needs, - the ability of the building to exploit the available energy resources. The method is mainly based on energy simulation and the basic data is a comparison of the behaviour of a building with and without a given environmental resource. The building energy needs without the resource can be compared to the resource potential and this comparison give the useful potential of the resource. Moreover, by comparing the building energy needs in the simulation with and without resource, we can get the amount of energy actually used by the building. From these two quantities, the useful and the exploited potential, a set of indicators can be defined and adapted to thermal comfort (heating and cooling needs) and three resources (sun, sky and air). The indicators are then applied to a study case and the results are analysed not only at the scale of the building, but also at the scale of each part of the envelope. A first analysis of the global results over the year is performed to get a first understanding of the state of the resources and the building performances. In a second step, the values are analysed at each time step, to characterize the behaviour of the building towards the environment. Finally, the indicators can be used to design buildings, in several ways. We performed a parametric analysis of the insulation level over the potential and performance indicators. Then, we used them to assess the bioclimatic performances of existing solar technologies. In a final step, the indicators have been used as criteria to optimize the building envelope parameters. Thus, the envelope parameters are optimized according to the minimization of the energy need, but also according to the maximization of the exploited potential.
59

Quantification de dégâts sur le bâti liés aux catastrophes majeures par images satellite multimodales très haute résolution

Chesnel, Anne-Lise 15 September 2008 (has links) (PDF)
Lors d'une catastrophe majeure, il est nécessaire de connaître rapidement l'importance des dégâts sur les bâtiments. Actuellement, cette quantification de dégâts se fait manuellement par comparaison visuelle d'images satellite. Les méthodes automatiques sont immatures ; leurs performances étant rarement évaluées, elles ne sont pas utilisées par les opérationnels. Nous proposons un protocole standard d'évaluation des performances de méthodes de quantification de dégâts. Il s'appuie sur des bases de données de référence obtenues pour cinq cas de catastrophes variées. Celles-ci contiennent pour chaque bâtiment l'emprise de son toit dans chaque image, ainsi qu'un degré de dégâts. Le protocole permet de quantifier les performances d'une méthode et de confronter ses résultats à d'autres. Disposant de ce protocole d'évaluation, nous proposons une méthode de quantification de dégâts à partir d'un couple d'images satellites panchromatiques de très haute résolution (THR) spatiale et d'un ensemble d'objets d'intérêt définis dans l'image de référence. La méthode développée doit pouvoir conduire à des résultats satisfaisants et reproductibles en utilisant des images de modalités différentes, et être automatisée au mieux. Les dégâts sur les bâtiments sont quantifiés par l'amplitude des changements sur leurs toits. Pour comparer ces derniers, ils doivent être alignés. Le recalage géométrique des données THR est un problème complexe non résolu ; une nouvelle méthode adaptée à notre problème est développée et évaluée. Elle aboutit à des résultats généralement satisfaisants pour notre application. Des indices de changements sont ensuite extraits. Deux coefficients de corrélation et des indices de texture obtenus par filtrage sont extraits, et un degré de dégâts est attribué à chacun des bâtiments par classification supervisée. L'impact des différences de modalité des images sur les performances de notre méthode est évalué. La méthode proposée est rapide, en grande partie généralisable et robuste à l'utilisation d'images THR de différentes résolutions ou issues de couples multicapteurs ; le paramètre influant est le B/H du couple.
60

Extraction 3-D de structures industrielles sur des images RAMSES haute résolution par radargrammétrie

Simonetto, Elisabeth 30 April 2002 (has links) (PDF)
Cette thèse concerne l'élaboration d'une chaîne de traitements radargrammétrique conduisant aux structures 3-D à partir d'images radar haute résolution. L'intérêt de la cartographie 3-D par imagerie RSO (Radar à Synthèse d'Ouverture) est que l'image radar peut être acquise par tout temps et de jour comme de nuit. Nous disposons d'images issues du capteur expérimental RAMSES de l'ONERA et représentant des scènes industrielles. Ces données contiennent de nombreux échos forts et les toits des structures sont peu visibles. Ces phénomènes rendent difficile l'interprétation des images et insuffisantes les méthodes classiques de reconstruction 3-D. Face à ces particularités, nous menons l'analyse radiométrique et géométrique des données. Cette analyse aboutit à la proposition d'une chaîne algorithmique adaptée qui vise à restituer les structures cylindriques et parallélépipédiques telles que cuves et bâtiments de forme simple. Dans la première partie concernant l'analyse, nous donnons l'interprétation simplifiée de l'image radar d'une structure et étudions les statistiques des images d'amplitude. L'opportunité de la radargrammétrie haute résolution est vérifiée théoriquement puis expérimentalement. La seconde partie présente la chaîne radargrammétrique. Notre approche comprend deux étapes principales : l'extraction des structures à partir des échos forts puis l'estimation du 3-D. L'extraction des structures fait l'objet d'un chapitre important de cette thèse. Nous proposons une méthode permettant la reconnaissance de la forme englobant la structure brillante, circulaire ou rectangulaire, par optimisation d'un critère surfacique. Nous la comparons avec des techniques plus classiques de traitement d'images et étudions plusieurs critères ainsi que l'apport de méthodes d'optimisation stochastique. Nous présentons ensuite une méthodologie pour obtenir les altitudes du sol entre les structures détectées et leur hauteur. Les résultats montrent la pertinence de l'approche lorsque la structure a été détectée et dans le cas favorable où un écho du toit est détectable.