• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 158
  • 8
  • 6
  • 6
  • 3
  • 1
  • Tagged with
  • 182
  • 55
  • 49
  • 47
  • 41
  • 40
  • 37
  • 35
  • 35
  • 35
  • 35
  • 35
  • 34
  • 33
  • 28
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Circuitos integrados de bajo consumo para aplicación en sistemas biomédicos

Pareja Obregón, Pablo D. 30 March 2012 (has links)
La microelectrónica y las redes de sensores se encuentran entre las áreas tecnológicas con mayor diversidad de campos de aplicación. Así, dispositivos que antiguamente no requerían nada de inteligencia, hoy en día incorporan procesadores y otros sistemas que facilitan su uso o le agregan funcionalida-des, como permitir su accionamiento a distancia o vericar su estado. En particular, la medicina es una de las disciplinas afectadas con mayor impacto asociado.Día a día, aplicaciones del campo de la tecnología e información se expanden en hospitales alrededor del mundo, encontrando desde disposi-tivos que permiten localizar un paciente dentro del hospital, hasta redes de datos que permiten revisar la historia clínica del paciente aún cuando sus tratamientos anteriores se hayan realizado en otros hospitales, clínicas o incluso consultorios privados. La motivación del presente trabajo es realizar redes de sensores hospitalarias, que incluyan diversos sistemas de medición de variables médicas en pacientes. Durante el tra-bajo realizado se investigaron los dispositivos comerciales exis-tentes para la medición de una serie de parámetros vitales básicos y se decidió abordar el diseño de circuitos integrados de bajo consumo para tres problemas en particular. El primero de ellos es un sensor destinado a la medición de presión endotraqueal en pacientes intubados. El segundo sistema diseñado tiene como función la medición de dosis de suero intravenoso en pacientes internados, así como el control de su dosificación. Finalmente, el tercer circuito consta de un sensor basado en nanotubos de carbono, destinado a la medición de agentes biológicos y gases. Todos los diseños de circuitos integrados se realizaron utilizando herramientas de diseño de esquemáticos, simulación y realización de más-caras, y los circuitos fueron fabricados utilizando un proceso de 0;5 m. Los circuitos fueron verificados en el Laboratorio de Micro y Nano Electrónica de la Universidad Nacional del Sur. / Microelectronics and sensor networks are among the most diverse technological areas of applied sciences. Devices that previously did not require any intelligence, nowadays incorporate processors and other systems that facilitate their use or add features, such as allowing their remote operation or checking their status. Medicine is one of the areas of science with greater associated impact. Day by day, information and technology applications expand in hospitals around the world, ranging from devices that locate a patient within the hospital, to dta networks that allow the revision of the patients medical history, even when previous treatments were performed at other hospi-tals, clinics or private practices.The motivation of this work is to design hospital sensor networks, including systems to measure health variables in patients. During this work, existing commercial devices for measuring a number of basic and vital parameters were investigated and it was decided to address the design of low power integrated circuits for three particular issues. The first is a sensor for the measurement of pressure in endotra-cheal intubated patients. The second design is a system for the measurement and control of the infusion of liquid substances in intravenous therapy. Finally, the third circuit consists of a sensor based on carbon nanotubes, intended for the measurement of biological agents and gases. The integrated circuits designs were made using schematic design, simulation and layout tools, and circuits were fabricated using a 0;5 m process. The circuits were tested in the Laboratorio de Micro y Nano Electrónica at the Universidad Nacional del Sur.
2

Factores de riesgo asociados a score de apgar bajo en el servicio de neonatología del Hospital de Ventanilla de julio a diciembre del 2016

Torres Alarcón, Derly Rocío January 2017 (has links)
Según la OMS la mortalidad perinatal representa más de la mitad de la mortalidad infantil; en el Perú representa el 52.9%1,2, esta puede disminuir tomando acciones que sean oportunas a nivel primario de salud. OBJETIVO: Determinar los factores de riesgo que se asocian a score de Apagar bajo en el servicio de Neonatología del Hospital de Ventanilla. MÉTODOS: se realizó una investigación analítica, retrospectiva de tipo caso control en 160 recién nacidos en el servicio de neonatología del Hospital de Ventanilla periodo de julio a diciembre del 2016 divididos en 2 grupos:80 recién nacidos con Apgar <7 y 80 con Apgar ≥7.Los datos fueron procesados mediante el paquete estadístico SPSS V 22.0 utilizando para el análisis OR con IC95%, y la prueba chi -cuadrado p<0.05. RESULTADOS: el análisis estadístico encontró que los factores de riesgo fueron el embarazo adolescente (OR=3.6 p<0.003), ITU en gestantes (OR=4.0 p <0.000), Preeclampsia (OR=4.5 p=0.015), cesárea (OR=2.33 p<0.020), prematuridad (OR=4.0 p <0.012), bajo peso al nacer (OR=5.5 p <016), liquido meconial espeso (OR=8.2 p<0.002) circular de cordón (OR= 4.9 p<0.00), control prenatal deficiente (OR= 4.5 p =0.00) CONCLUSIONES: Los factores de riesgo que se asocian a score de Apagar bajo al nacer fueron el embarazo adolescente, la Preeclampsia, ITU en gestante, el tipo de parto “Cesárea”, el líquido meconial espeso, la prematuridad, el bajo peso al nacer, el circular de cordón y la atención prenatal deficiente
3

Topics in Nevome syntax /

Shaul, David Leedom, January 1986 (has links)
Texte remanié de: Thesis--University of California--Berkeley, 1982. / Bibliogr. p. 137-140.
4

Amplificadores de muy bajo ruido y mínimo consumo de energía, para aplicaciones médicas implantables

Miguez De Mori, Matías Rafael 14 November 2016 (has links)
Este trabajo se centra en los amplificadores de muy bajo ruido y micro-consumo de potencia, tomando como ejemplo la detección de señales nerviosas (ENG) para su aplicación en dispositivos implantables. Si bien el ancho de banda de las señales médicas es reducido, como son en muchos casos de amplitud extremadamente pequeña, la principal dificultad para el diseño de circuitos será el bajo ruido combinado con micro o nano-consumo de potencia. En efecto, existe una relación de compromiso conocida entre ruido a la entrada y consumo de corriente en un amplificador que el diseñador debe optimizar. Este trabajo esencialmente intenta responder la pregunta: ¿cómo aprovechar al máximo la energía disponible en la batería de un implante para alimentar un amplificador de muy bajo ruido? A lo largo de esta tesis se presentarán técnicas innovadoras de circuito para aprovechar mejor la energía disponible. En primer lugar, se analiza el uso de los espejos activos como sustitución de los espejos de corriente de dos transistores tradicionales. Se estudiaron analíticamente y mediante simulaciones las ventajas y desventajas; luego se diseñó, fabricó y caracterizó un espejo de corriente activo que funciona como fuente de corriente de 10μA con menos de 100mV de caída de voltaje en una tecnología de 0.6μm. En segundo lugar, se presenta la idea de reutilización de corriente apilando sucesivos pares diferenciales como forma de aprovechar todo el rango de tensión de la batería en un circuito analógico. Se demuestra en forma analítica y con medidas sobre un circuito fabricado, que la técnica es extremadamente eficiente en el compromiso entre consumo de corriente y ruido. Se diseñó, fabricó, y caracterizó un amplificador para señales ENG que apila doce pares diferenciales de entrada funcionando con una batería de 3.6V (nominales), con un consumo total de 16.5μA y una ganancia en la banda pasante de ≈80dB. Tiene un ancho de banda de 4kHz y el ruido medido a la entrada de 4.5nV/Hz1/2@1kHz y 330nVrms en la banda de interés. El amplificador tiene un NEF medido de 0.84, incluso considerando el consumo de todos los circuitos auxiliares, lo cual parece ser el primer amplificador reportado con un NEF<1. Finalmente, se estudia un conversor DC-DC inductivo de microconsumo como otra alternativa para reducir el consumo de corriente de la batería en circuitos analógicos. Se diseñó, fabricó y caracterizó un conversor DC-DC inductivo del tipo step-down, que reduce el voltaje de 3.6V a 0.6V para un consumo de 36μW. Este conversor podría alimentar un solo par diferencial complementario (un NMOS y un PMOS apilados) con seis veces más corriente, en sustitución de los seis pares diferenciales complementarios apilados previamente. / This work focuses on electronic amplifiers with very low noise and micro/nano power consumption. We selected an amplifier for the detection of nerve signals (ENG) in implantable medical devices as a case study. While the bandwidth of medical signals is relatively low, as the signals are generally of extremely low amplitude, the main challenge for the circuit designer is to achieve low noise combined with low power consumption. Indeed, there is a well-known relationship between noise at the amplifier’s input and electrical current consumption of the amplifier. In this work, we evaluated how to power a low noise amplifier using the maximum amount of available energy from an implantable device’s battery. Throughout this thesis, we present novel circuit techniques to better utilize the available energy. Firstly, we analyzed the use of active mirrors instead of traditional two transistor current mirrors. We studied the advantages and disadvantages of active mirrors analytically and with simulations. We designed, fabricated and tested an active mirror that works as a 10μA current source with less than 100mV voltage drop in a 0.6μm technology. Secondly, we introduced the idea of reusing current by stacking differential pairs, to better utilize the voltage range of the battery. This topology is shown to be extremely efficient in the trade-off between current consumption and generated noise. We designed, fabricated and tested an amplifier for ENG signals that stacks twelve differential pairs and works with a 3.6V (nominal) battery, consumes 16.5μA and has a gain of ≈80dB in the passing band. The amplifier has a bandwidth of 4kHz, and a measured noise of 4.5nV/Hz1/2@1kHz and 330nVrms in the band of interest. The amplifier has a measured NEF of 0.84 even considering the consumption of all the auxiliary circuits, which makes it, to the best of our knowledge, the first amplifier reported with an NEF<1. Finally, we studied inductive DC-DC converters with micro-consumption as an alternative way to reduce consumption without introducing extra noise. We designed, fabricated and tested a step-down inductive DC-DC converter, that reduces voltage from 3.6V to 0.6V for a 36μW load. This converter could power one complementary differential pair (only one stacked PMOS and NMOS differential pair) with six times the electrical current, and could be used instead of the six complementary differential pairs used previously.
5

Anemia en gestantes como factor de riesgo asociado a bajo peso al nacer en el hospital nacional de policía LUIS N. SÁENZ entre los años 2014 - 2015

Cárdenas Mendoza, Stephanie January 2017 (has links)
Objetivo: Determinar si la anemia en gestantes es factor de riesgo asociado a bajo peso al nacer en el Hospital Nacional de Policía Luis N. Sáenz de enero del 2014 a diciembre del 2015. Métodos: Estudio observacional, analítico, retrospectivo, longitudinal, de casos y controles. La población consta de 1547 gestantes que presentaron recién nacidos vivos entre el 1 de enero de 2014 y el 31 de diciembre del 2015 en el Hospital Nacional de Policía Luis N. Sáenz. Se contó con todos los casos (40 casos) y 120 controles, escogidos al azar. La información fue recogida en el formulario de recolección de datos. Se analizaron las medidas de asociación mediante la razón de momios (OR). Se utilizó un intervalo de confianza del 95% y se aplicó el estadístico chi cuadrado con un nivel de significancia estadística menor al 0,05. Resultados: Los resultados obtenidos sobre el nivel de asociación fueron: anemia en gestantes [(OR:2,5) IC95% 1,154-5,548 p:0,018], anemia en el primer trimestre de gestación [(OR:2,4) IC95% 1,032-5,981 p:0,038], anemia en el segundo trimestre [(OR:1,5) IC95% 0,503-4,908 p:0,434], anemia en el tercer trimestre de gestación [(OR:4) IC95% 1,267-12,821 p:0,012], número insuficiente de controles prenatales [(OR:4) IC95% 1,360-11,975 p:0,008]. Conclusiones: Se concluye que la anemia durante el primer y tercer mes de gestación es factor de riesgo de bajo peso al nacer.
6

Prevalencia y características clínicas de Enterocolitis Necrosante en RN Pretermino menores de 1500g en la unidad de cuidados intensivos neonatales del Hospital Sergio Bernales de noviembre 2013 a noviembre 2015

Esquivel Borjas, Priscilla January 2016 (has links)
OBJETIVO: Conocer la prevalencia y características clínicas de Enterocolitis Necrosante en recién nacidos pretermino menores de 1500g en UCIN del Hospital Nacional Sergio Bernales de Noviembre 2013 – Noviembre 2015. MATERIAL Y METODOS: Se realizó un estudio de tipo observacional, descriptivo, retrospectivo en la UCIN del Hospital Nacional Sergio E. Bernales, donde se encontraron 11 recién nacidos vivos prematuros y con un peso menor de 1500 gr que cumplieron con los criterios de inclusión. Se revisó el libro de los registros de ingresos en el servicio de UCI de neonatología, el instrumento utilizado fue la ficha de recolección de datos. Finalmente, se realizó un análisis descriptivo utilizando el paquete estadístico SPSS (Statistical Package for the Social Sciences) versión 23. RESULTADOS: Durante el periodo de estudio ingresaron 716 recién nacidos a la UCI neonatal en el Hospital Sergio E. Bernales , donde 389 eran prematuros, de los cuales solo 106 tenían muy bajo peso al nacer y de estos solo 11 (10,38%) presentaron Enterocolitis Necrosante , se observó que el 54,55%(6) fueron de sexo femenino y 45,45 % (5) masculinos, en cuanto al peso se encontró 63,64% (7) con muy bajo peso y 36,36% (4) extremo bajo peso. El 9,9% era prematuros extremos, 18,18 % muy prematuros y el 72,73 % de moderado prematuros, no hubieron casos de prematuros cerca a término ( 35 -36 ss) . El apgar al primer minuto de vida fue de 72,73 % con apgar entre 7 a 10 y 9,09 % un apgar de 0-3. El apgar a los 5 minutos fue de un 9,09% con depresión moderada y un 90,91% con un apgar normal. El 100% curso con sepsis, 72,7 % con enfermedad de membrana hialina, 18,1% ictericia del prematuro y asfixia junto a Taquipnea transitoria del RN ambos con un porcentaje de 9,09%. CONCLUSIÓN: Se encontró que la prevalencia de enterocolitis Necrosante es similar a lo descrito en la literatura además de presentarse con mayor frecuencia en recién nacidos prematuros
7

Factibilidad de implementación del material suelo-cemento como material de construcción para viviendas de bajo costo en el Perú

Valdivia Cariat, José Augusto 04 November 2016 (has links)
El objetivo de la presente investigación es determinar si es factible implementar el suelocemento como material de construcción en viviendas de bajo costo en el Perú. Se pretende mitigar la situación generada por dos contextos claramente marcados. El primero de ellos se refiere a la falta de vivienda, tanto cualitativa como cuantitativamente, que hay en el país, y el segundo alude a la falta de oferta inmobiliaria para los sectores socio-económicos bajos. En respuesta a la problemática indicada en el párrafo anterior, la investigación considera el uso del suelo-cemento en un sistema constructivo (albañilería reforzada con malla exterior) con poca variación en relación a la construcción tradicional con adobe, típica en nuestro país. En el desarrollo de la investigación se presenta una revisión bibliográfica con los aspectos más resaltantes del material suelo-cemento. Luego, se propone un módulo de vivienda para comparar las técnicas constructivas del suelo-cemento con las de la albañilería confinada de ladrillos de arcilla, así como los costos asociados a cada uno de los sistemas. Adicionalmente, se plantea un conjunto de recomendaciones que sirvan de pautas básicas para la elaboración de una norma nacional de suelo-cemento, con un enfoque empírico. Finalmente, se anotan las conclusiones más resaltantes del análisis indicado. / Tesis
8

Frecuencia de los Factores de Riesgo Biológicos, Obstétricos, Socio Económicos y Entidades Clínicas Asociadas a Bajo Peso al Nacer en Pacientes del Servicio de Neonatología del Hospital Hipólito Unanue de Tacna Durante el Período Enero – Diciembre del Año 2012

Sandoval Torres, Karla Paola 13 September 2013 (has links)
A nivel mundial nacen cada año 19 millones de niños con peso menor de 2,500 g., lo que representa una incidencia de 14%. En los países industrializados la incidencia promedio de bajo peso al nacer es de 7%; contrariamente se aprecia que, en los países en desarrollo alcanzan cifras mucho más altas, siendo actualmente 15% de BPN. El objetivo del presente estudio es determinar la frecuencia de los factores de riesgo biológicos, obstétricos, socioeconómicos y entidades clínicas asociadas a Bajo Peso al Nacer en pacientes del Servicio de Neonatología del Hospital Hipólito Unanue de Tacna durante el período Enero-Diciembre del año 2012. Es un estudio descriptivo, retrospectivo y transversal. Se pudo evidenciar que los factores de riesgo para el BPN en recién nacidos con mayor frecuencia fueron: las edades extremas en las madres, baja ganancia ponderal, madres primíparas, periodo intergenésico corto, antecedente de aborto, madre conviviente, estudios secundarios, y la anemia y RPM como entidades clínicas asociadas.
9

Sobrevivencia del recién nacido menor de 1500 gramos en el Hospital Nacional San Bartolomé 2001-2005

Loayza Pérez, Gerardo Iván January 2007 (has links)
Objetivo.- Conocer las características epidemiológicas y clínicas de los recién nacidos con menos de 1500 gramos en el hospital San Bartolomé durante el periodo de Enero del 2001 hasta Diciembre 2005. DISEÑO.- Estudio retrospectivo, descriptivo y observacional. Material y Métodos.- El estudio se realizó en el servicio de neonatología del Hospital Nacional docente Madre Niño San Bartolomé (HONADOMANI), Lima – Perú, en el periodo comprendido entre Enero del 2001 y el 31 de Diciembre del 2005, la población de estudio fueron todos los menores de 1500 gramos. Esta información será generada por la oficina del SIP (Sistema Informático peri natal) del HONADOMANI San Bartolomé.
10

Comportamiento de las Soluciones Básicas de Carpetas de Rodadura Aplicadas a Caminos de Bajo Tránsito

Cavieres Acevedo, Waldemar Pablo January 2008 (has links)
Las Soluciones Básicas, según lo establece la Dirección de Vialidad, son mejoramientos de la carpeta de rodadura, aplicables a caminos de bajo tránsito, con pavimentaciones distintas a las tradicionales, las cuales podrían ser alternativas válidas para los más de 60.000 kilómetros de caminos aun sin pavimentar. Entre los tipos de “Soluciones Básicas” desarrolladas, se encuentran: Estabilización de carpetas granulares superficiales: esto consiste en adicionar a los suelos o carpetas granulares productos que permitan aglomerar la fracción fina de estos. Entre los productos que se utilizan, se encuentran sales minerales y productos ligantes o aglomerantes. Recubrimientos asfálticos: entre éstos están diversos tratamientos superficiales tales como los riegos neblina (fogseal), sellos asfálticos, riegos con gravilla, lechadas asfálticas, carpetas asfálticas de pequeño espesor y combinaciones de ellos. Mejoramientos de la base granular y luego una protección asfáltica, que puede considerarse como una combinación de las soluciones anteriores. En este trabajo de título se aborda la caracterización de los tipos de soluciones básicas que han sido utilizados en diferentes contratos a lo largo del país y evalúa su factibilidad como solución para el resto de la red comunal no pavimentada. Como etapa previa se realizó una revisión de la información existente sobre los proyectos ejecutados, partiendo de su clara identificación y datos sobre su comportamiento en relación a las condiciones locales de clima, suelo y tránsito que lo utiliza. Para evaluar el comportamiento se utilizaron indicadores de estado, los cuales fueron obtenidos a través de inspecciones visuales a los distintos caminos mejorados mediante soluciones básicas, registrando en una ficha el nivel de deterioro, mediciones de IRI y deflectometría efectuadas por el Laboratorio Nacional de la Dirección de Vialidad. El comportamiento observado de las Soluciones Básicas, permite afirmar que es posible aplicar algún tipo mejoramiento de la carpeta de rodadura en casi cualquier lugar del país, considerando una adecuada elección, construcción y mantención.

Page generated in 0.0476 seconds