• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • 1
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Temperatursprickskatalogen : Hjälpmedel vid beräkning av temperatursprickor i vanligt förekommande  betongkonstruktioner. / Thermal crack catalogue : Assistance when calculating thermal cracks in common concrete structures.

Swärd, Sofia, Hallberg, Markus January 2012 (has links)
Rapporten innehåller inledningsvis en faktadel med allmän information kring temperatursprickor i betong. Här presenteras bl a uppkomsten av fenomenet, vilka typer av sprickor som förekommer och vad ett tvång är. Tanken är att ge läsaren tillräcklig kunskap för att kunna förstå sig på de övriga delarna i rapporten. Resultatet och det huvudsakliga arbetet redovisas i form av tabeller med tillhörande illustrationer där det går att utläsa vilken sprickrisk som förekommer vid flera specifika fall och vilken åtgärd som bör vidtas för att eliminera sprickrisken. Som konstruktör kan du med din egen indata, dvs. dimensioner och temperaturer, följa tabellen och finna resultatet för ditt specifika fall. De konstruktionstyper som presenteras är bottenplatta, stödmur och plattrambro. En tillhörande databas i elektronisk form finns tillgänglig som en bilaga där varje beräknat fall är sparat. Filerna är enkla att modifiera för att göra det möjligt att genomföra ytterliggare beräkningar i de fall tabellerna är otillräckliga. Rapporten innehåller även ett avsnitt med förutsättningar till tabellerna där det går att utläsa arbetsgången och vilka parametrar som har använts. / The initial part of the report contains general information about thermal cracks. This section describes the origin to the cracks, what type of cracks that occurs and the force causing the problem. The major reason with this chapter is to give the reader enough knowledge to understand the rest of the report. The result and the main work are presented in tables with belonging illustrations. Each table contains the risk of cracking that occurs in several specific concrete structures and how to eliminate the risk. The report covers the following three types of structures: baseplate, retaining wall and integral bridge. The constructor can with his/her own dimensions and temperatures simply use the table to find the risk of cracking. A database including all the calculated files for each specific case is attached to the report. The files can easily be modified by the user in case the information in the tables is insufficient. All the precise circumstances and priority in the project are presented in the chapter “Förutsättningar och arbetsgång”.
2

Simulation of Hardening of the MahanaKhon Tower Mat Foundation

Kazi-tani, Zakaria January 2019 (has links)
Cement hydration is the result of a series of simultaneous chemical reactions occurring during the production of concrete. An excessive amount of heat is generated, which consequently may give rise to thermal stresses and cause early age cracks in concrete that may affect its structural integrity, and load bearing capacity. Incorporating fly ash into the concrete mixture has shown to be an efficient method to reduce the temperatures developed during early age hydration, especially for massive concrete structures. Fly ash does additionally affect the concrete's development of compressive strength, tensile strength and Young's modulus. The MahanaKhon tower's mat foundation is divided into 14 layers, with fly ash incorporated in the concrete mix. A finite element model was developed of the mat foundation with COMSOL Multiphysics to simulate the developed temperatures and thermal stresses during curing. The simulations were carried out as parametric studies with different strain reference temperatures. The simulated temperatures were compared with existing temperature measurements that were conducted in three different elevations in each concrete layer. The result of the temperature analyses showed that the measured temperatures were generally larger than the simulated ones, which may have been the result of the numerical model's heat conductivity and convective heat transfer coeffcient not reflecting the actual case. Furthermore, the numerical model did not take into account the effects of solar radiation, which would most likely have increased the temperature of the concrete. The maximum simulated temperatures were mostly found in the center level of the concrete, followed by the lower level, and the lowest at the top. It was also observed that the maximum temperatures in some of the mat foundation layers could exceed 70 °C, which is generally considered high since the risk of delayed ettringite formation may arise. The large temperature is partially a result of not using cooling methods, such as cooling pipes, but also due to the high initial and ambient temperatures. The result of the thermal stress analyses showed that no tensile stresses arose when the strain reference temperature, Tref, was specified to 30 °C, corresponding to the mean ambient temperature. This is due to the concrete temperature not falling below Tref, and the concrete will therefore be in expansion and only be subject to compressive stresses. Increasing Tref to 50 °C, which was considered a reasonable estimation, resulted in developed tensile stresses in all mat foundation layers, where the majority of the mat foundation layers showed a risk of superficial surface cracks. The maximum tensile stresses were found at the final time of the simulations, which was expected, since the temperatures were at their lowest as a result of removing the curing insulation. Finally, setting Tref to 70 °C, corresponding to the maximum temperature during hardening, increased the induced tensile stresses considerably, due to the large temperature gradient between Tref and the concrete temperature. The maximum stresses were, as expected, located at the top level and caused by internal restraint. The second largest tensile stresses were found in the center level, also subject to internal restraint. The lowest tensile stresses were located in the lower level, subject to external restraint. / Cementhydratation är resultatet av en serie kemiska reaktioner som sker under tillverkningen av betong. Stora mängder värme genereras, vilket följaktligen kan ge upphov till termiska spänningar och orsaka tidig sprickbildning som påverkar betongens hållfasthet, och bärförmåga. Inkludering av flygaska i betongblandningen har visat sig vara en effektiv metod avsedd att minska temperaturerna som utvecklas under hydratationen i ung betong, särskilt i massiva betongkonstruktioner. Flygaska påverkar också betongens utveckling av tryckhållfasthet, draghållfasthet och elasticitetsmodul. MahanaKhon towers bottenplatta är uppdelad i 14 lager, där flygaska inkluderades i bottenplattans betong. En finit elementmodell av bottenplattan skapades i COMSOL Multiphysics, där de utvecklade temperaturerna och termiska spänningarna i den unga betongen simulerades under bottenplattans härdningsfas. Simuleringarna genomfördes som parameterstudier med olika referenstemperaturer. De simulerade temperaturerna jämfördes vidare med befintliga temperaturmätningar som utfördes i tre olika elevationer i varje gjutetapp. Resultaten av temperaturerna visade att de uppmätta temperaturerna var generellt högre än de simulerade, vilket bland annat kan bero på att betongens värmeledningsförmåga, samt konvektiva värmeöverföringskoefficient inte återspeglade det aktuella fallet. Den numeriska modellen tog inte heller hänsyn till effekten av solinstrålning, som sannolikt skulle ökat betongens temperatur. De maximala temperaturerna hittades mestadels i betongens mittnivå, följt av den lägre nivån och slutligen lägsta nivåerna vid toppen. Det observerades även att de maximala temperaturerna i bottenplattan kunde överstiga 70 °C, vilket generellt anses vara högt då risken för fördröjd ettringitbildning kan uppstå. De höga temperaturerna beror delvis på avsaknad av kylmetoder, såsom kylrör, men även på den höga initialtemperaturen och omgivningstemperaturen. Resultaten av spänningsanalysen påvisade att inga dragspänningar uppstod när referenstemperaturen Tref denierades till 30 °C, som motsvarar den genomsnittliga omgivningstemperaturen. Detta förklaras av att betongen kommer att vara i expansion och följaktligen endast utsättas för tryckspänningar. Efter att Tref ökats till 50 °C, vilken ansågs vara en rimlig estimering i denna studie, uppstod dragspänningar i alla lager i bottenplattan, där vissa utsattes för risk för ytsprickor. De maximala dragspänningarna uppstod vid simuleringarnas slut, vilket var förväntat då temperaturerna var som lägst vid den tidpunkten till följd av att isoleringen avlägsnades. Slutligen höjdes Tref till 70 °C, vilket motsvarar den maximala temperaturen i bottenplattan under härdning. De inducerade dragspänningarna ökade avsevärt på grund av den stora temperaturgradienten mellan Tref och betongtemperaturen. Samtliga lager utsattes i detta fall för risk för genomgående sprickor. De maximala dragspänningarna påträffades på toppnivån och orsakades av inre tvång. De näst största dragspänningarna fanns i mitten av plattan och var också resultatet av inre tvång. De lägsta dragspänningarna påträffades vid plattans lägre nivå, som utsattes för yttre tvång.

Page generated in 0.0461 seconds