• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 14
  • 1
  • Tagged with
  • 19
  • 19
  • 13
  • 13
  • 9
  • 8
  • 8
  • 7
  • 6
  • 6
  • 6
  • 6
  • 6
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Application of the Grillage Methodology to Determine Load Distribution Factors for Spread Slab Beam Bridges

Petersen-Gauthier, Joel 16 December 2013 (has links)
Transverse load distribution behavior amongst bridge girders is influenced by many parameters including girder material properties, spacing, skew, deck design, and stiffening element interactions. In order to simply and conservatively approximate the bridge superstructure load distribution between girders, the American Association of State Highway and Transportation Officials (AASHTO) LRFD Bridge Design Specifications contain load distribution factor (LDF) equations for many common bridge types. The Texas Department of Transportation (TxDOT) had recently developed a new design for bridge superstructures that utilizes a spread configuration of prestressed concrete slab beams. AASHTO does not contain LDFs for this type of bridge so the load sharing behavior of this superstructure must be investigated further. TxDOT has funded the Texas A&M University Transportation Institute (TTI) to design, model, construct, test, and analyze a full scale spread slab beam bridge. In addition to this testing, an existing slab beam bridge in Denison, Texas will be instrumented and observed for supplementary slab beam behavior data. To predict bridge behavior, computer models of the Riverside experimental bridge and of the Denison field bridge were developed using both the grillage and finite element methods of analysis. The experimental results from the Riverside and Denison bridges will not be collected by the conclusion of this thesis so a third bridge with existing experimental data, the Drehersville, Pennsylvania bridge, was also modeled for calibration purposes. The work presented by this thesis focuses on how to accurately model transverse load distribution relationships and LDFs for use in bridge design. The analysis covered is concentrated primarily on the grillage method, with the finite element analysis as part of the larger project scope. From this analysis it was determined that the grillage method was able to accurately model bridge LDFs as compared to FEM modeling and experimental results, for spread slab beam and spread box beam bridges. The critical loading configurations for all bridges placed two trucks side by side and as far to one edge of the bridge as possible. It was also determined that at an ultimate loading case, the load is distributed much more evenly across the deck than at service loading.
2

Structural Evaluation of LIC-310-0396 Box Beams with Advanced Strand Deterioration

Lab, Scott 05 August 2010 (has links)
No description available.
3

VHPC Material Characterization and Recommendations for the Buffalo Branch Bridge Rehabilitation

Field, Carrie Stoshak 28 August 2015 (has links)
Adjacent box beam bridges are economical bridge systems for accelerated bridge construction. The box beams are constructed at precast plants and are traditionally connected by a shear key filled with grout. This system is ideal for short spans with low clearance restrictions. However, due to the grout deteriorating and debonding from the precast concrete in the shear key, reflective cracking propogates through the deck allowing water and chemicals to leak down into the joints. This can lead to the prestressing steel inside the precast member and the transverse tie steel corroding. This necessitates the bridge being rehabilitated or replaced which shortens the life-span of the bridge system and negates the economical value it had to begin with. This research project aimed to design a rehabilitation plan for an adjacent box beam bridge with deteriorated joints using Very High Performance Concrete (VHPC). VHPC was chosen as an economical alternative to the proprietary Ultra High Performance Concrete (UHPC) and extensive material tests were performed. The results of the material testing of VHPC and grout revealed that VHPC had higher compressive and tensile strengths, a higher modulus of elasticity, gained strength faster, bonded better to precast concrete, was more durable over time, and shrank less than conventional grout. The results of this research project were applied to rehabilitate the Buffalo Branch Bridge and further testing will be completed to determine the effectiveness of the rehabilitation. / Master of Science
4

Box Beam / Box Beam

Lai, Jackie, Huynh, Johnny January 2016 (has links)
This report covers the product development process of a C-profile forming a box beam for use in storage systems. The company Brännehylte Lagersystem AB is in need of a new box beam that in pair can handle a maximum load of 4000 kg (four pallets x 1000 kg). At present the company has only one beam capable of a maximum load of 4x800 kg and wants to expand its product range and develop as a company and compete with others in the storage systems market. The first step began with acquiring information on the different beams and how they behave under stress. Then began a combination of brainstorming and brainwriting to generate a number of concepts of how a C-profile could possibly look like. After screening of the different concepts using Gut-feeling method three most appropriate concepts were left and were pitted against each other in a Pugh Matrix to get the best possible C-profile for further development. Calculations and tests were done on the selected concept with a combination of elementary cases and SolidWorks. For the beam to be approved it must meet the EU standard for storage racks. The calculated beam resulted in a working beam in theory, which in turn must be produced to confirm that the theory is true. Because a prototype must be produced in order to confirm the results, then the work cannot be proven in practical example and only be proven in theory.
5

Three-Dimensional Finite Element Modeling of Non-Composite and Composite Adjacent Box Beam Bridges

Al Shawawreh, Sewar F. 25 September 2018 (has links)
No description available.
6

Destructive Testing of a Full-Scale 43 Year Old Adjacent Prestressed Concrete Box Beam Bridge: Middle and West Spans

Huffman, Jonathan M. 18 April 2012 (has links)
No description available.
7

New Approach to Connections Between Members of Adjacent Box Beam Bridges

Halbe, Kedar Ram 04 September 2014 (has links)
The adjacent box beam bridges (ABBB) are considered as an ideal solution for short to medium span bridges and for routes with low to medium traffic volumes. The ABBB system has been utilized and is popular in several states in the United States. However, this bridge system has long term durability issues caused by shear key failure and reflective cracking in the topping. The means and methods to alleviate the problems in connections between members of the ABBB were researched and the development of new connection details was pursued. Diagnostic tests to study the in-service behavior of ABBBs was performed. Two bridges with varying magnitude of joint deterioration were investigated. Both bridges were instrumented extensively and were subjected to known loads in the form of tandem trucks. The response of these bridges was studied and conclusions were made about the state of the bridges and the behavior after shear key failure. A finite element (FE) model of one of the tested bridges was developed to study the response of an ABBB with sound joints. The results of the finite element analysis (FEA) were compared with the results of the bridge diagnostic test. Conclusions about the FE model were made on the basis of this comparison. Another FE model, referred as the full scale bridge (FSB) was developed. The FSB model was used to simulate the behavior of an ABBB with the proposed connection details. This FSB model was subjected to design truck loads and the response was studied. The behavior of FSB model was replicated through a three beam sub-assembly that was supported on elastic supports. The stiffness of the elastic supports was calibrated such that the state of stress in the joints and the relative displacements between adjacent box beams in the sub-assemblage matched those in the FSB. The three beam sub-assembly was constructed with the proposed connection details. Two new connection details were proposed in this research. A Kevlar and epoxy connection and a spliced connection with fiber reinforced self-consolidating concrete are proposed. A total of six specimens, with different connection details, were constructed and tested for strength and durability in the laboratory. The behavior of the proposed connections and the connection materials were studied in detail. Additional FEA was performed to study the effect of shrinkage and temperature on the proposed connection details. / Ph. D.
8

Development of a Magnetic Field Sensor System for Nondestructive Evaluation of Reinforcing Steel in Prestressed Concrete Bridge Members

Fernandes, Bertrand January 2012 (has links)
No description available.
9

Bridge Load Rating Using Dynamic Response Collected Through Wireless Sensor Networks

Jaroo, Amer S. January 2013 (has links)
No description available.
10

Bridge Condition Assessment Using Dynamic Response Collected Through Wireless Sensor Networks

Hamid, Hiwa F. January 2013 (has links)
No description available.

Page generated in 0.0514 seconds