Avaliação do padrão de desempenho das equipes técnicas de mamografia frente ao uso de tecnologias digitais / Grading of the performance of the technical mamography teams, in lieu of the use of digital technologies

Oliveira, Evelyn Rosa de 07 April 2017 (has links)
Este estudo apresenta uma análise de rejeição, realizada na clínica Diagnóstico Avançado Por Imagem – DAPI, com dados de 647 mamografias rejeitadas realizadas de março a novembro de 2015, antes e após treinamentos realizados com a equipe técnica de mamografia, para análise do desempenho. As informações foram coletadas na base de dados do software de análise de rejeição dos mamógrafos, e incluem: incidência; quantidade de repetições; motivo da repetição; identificação da profissional; compressão do exame rejeitado e do exame aceito. Observou-se que após o treinamento os índices de rejeição por posicionamento (a maior causa das rejeições) foram reduzidos em 2%. Identificou-se que as profissionais desenvolveram critérios mais rigorosos, o que também contribuiu para aumento das repetições após o treinamento. A incidência mais rejeitada foi a Crânio Caudal Direita – CCD, tanto antes (32%) quanto após o treinamento (36%). A análise do desempenho da equipe técnica em relação aos critérios de qualidade em mamografia digital pôde ser realizada, uma vez que houve a análise individual das profissionais para contribuição da qualificação da equipe e aumento da qualidade dos exames. A profissional “A”, que possuía o maior índice de rejeição por posicionamento, após o treinamento houve uma redução de 17% das repetições devido a posicionamento inadequado. Foram identificadas imagens com qualidade aceitável que foram rejeitadas desnecessariamente: 8% antes e 3,6% após o treinamento. Antes do treinamento, a equipe técnica realizava as mamografias com valores de compressão entre 80 a 89 N, e após o treinamento a maioria dos exames foi realizada com 90 N ou mais. Esse aumento resulta em exames com melhor qualidade e menor dose para a paciente. / This study presents a rejection analysis performed at the clinic Diagnóstico Avançado Por Imagem - DAPI, with data from 647 rejected mammograms performed three months before and three months after a training session of the mammography team, to analyze the performance of them after the training. The information was collected in the database of mammography rejection analysis software,these data include: Incidence; Number of repetitions; Reason for the repetition; Identification of the professional; Rejection examination and accepted examination. It was observed that, after the training, the rejection indexes by positioning (the greatest cause of the rejections) were reduced. It was observed that the group developed rigorous criteria, which also contributed to increase the repetitions after the training. The most rejected incidence was Cranio Caudal Right - CCD, both before (32%) and after training (36%).The analysis of the performance of the technical team, in relation to the quality criteria in digital mammography, could be performed by the individual analysis of the professionals to contribute to the qualification of the team and to increase the quality of the exams. The "A" professional, who had the highest index of rejection by positioning, after the training there was a reduction of 17% of the repetitions due to improper positioning. Acceptable quality images have been identified that are rejected unnecessarily 8% before and 3,6% after training. Before the training, the technical team performed the mammograms with values of compression between 80 and 89 N, and after training most of the exams were performed with 90 N or more. This increase which results in better quality tests and lower dose for the patient.
32

Qualidade da imagem, limiar de contraste e dose glandular média em mamografia digital CR

Jakubiak, Rosangela Requi 30 January 2013 (has links)
Em muitos países, os sistemas de radiologia computadorizada (CR) representam a maioria dos equipamentos usados em mamografia digital. Este estudo apresenta um método para a otimização da qualidade da imagem e da dose em mamografia digital CR para pacientes com mamas de espessuras entre 45 e 75. As espessuras das mamas foram simuladas com placas de polimetilmetacrilato (PMMA). Técnicas de exposição otimizadas (tensão (kV), produto corrente-tempo (mAs) e combinação alvo/filtro) foram definidas como aquelas que fornecem uma razão contraste-ruído (CNR) ideal, denominada CNR alvo, que permite atingir o limiar de contraste das imagens do detalhe de diâmetro de 0,10 mm no simulador CDMAM (versão 3.4 Artinis Medical Systems, Netherlands) com um padrão de Dose Glandular Média (DGM) aceitável. Os resultados foram utilizados para os ajustes do Controle Automático de Exposição (CAE) pela equipe de manutenção. Um estudo retrospectivo de dois grupos de pacientes (Grupo 1-antes do ajuste do CAE e Grupo 2- após o ajuste do CAE) foi realizado. Os parâmetros de exposição foram reproduzidos nos simuladores para a determinação da CNR, da DGM e do limiar de contraste. As imagens clínicas destes pacientes foram analisadas por três radiologistas especialistas em mamografia que responderam questões sobre as estruturas anatômicas, ruído e contraste em áreas de valores de pixels altos ou baixos, sobre nitidez e contraste da imagem. Os resultados mostram que o método proposto foi efetivo para todas as espessuras de mama avaliadas. O ajuste do CAE proporcionou a concentração de valores da CNR no Grupo 2 mais próximas ao CNR alvo e que, mesmo como aumento do nível de ruído nas imagens clínicas, as análises do CDMAM mostraram que não houve prejuízo na identificação do objeto de 0,10 mm de diâmetro. Finalmente, este estudo conclui que o uso dos CAE das unidades de raios X baseados em fornecer uma dose constante ao detector pode ocasionar algumas dificuldades para alguns sistemas CR operarem nas condições ótimas. / In many countries, computed radiography (CR) systems represent the majority of equipments used in digital mammography. This study presents a method for optimizing image quality and dose in CR mammography of patients with breast thicknesses between 45 to 75mm. The breast thicknesses were simulated with polymethylmetacrylate (PMMA). Optimazed exposure parameters ((voltage (kV), mA and time product (mAs) and target/filter combination)) was defined as giving an ideal contrast to noise ratio (CNR), defined as target CNR, to reach the threshold contrast of CDMAM (version 3.4) phantom (Artinis Medical Systems, Netherlands) images for acceptable mean glandular dose (MGD). These results were used for adjustments in the automatic exposure control (AEC) by the maintenance team. A retrospective study of two groups of patients (Group 1-before AEC adjustment and Group 2- after AEC adjustment) were done. The exposure parameters were reproduced in the phantoms to determine of CNR, MGD and threshold contrast. The clinical images of these patients were analyzed by three experienced radiologists who answered questions about anatomical structures, noise and contrast in low and high pixel value areas and image sharpness and contrast. The results showed that the proposed method was effective for all breast thickness evaluated. The AEC adjustment showed a concentration of CNR in Group 2 nearer of target CNR, and that the increasing of noise in clinical images, the CDMAM analysis showed that this level of noise did not disturb the detail of 0,1 mm diameter. Finally, this study also concluded that the use AEC of X rays unit based on constant dose to the detector may bring some difficulties to CR systems operate in optimal conditions.
33

Qualidade da imagem, limiar de contraste e dose glandular média em mamografia digital CR

Jakubiak, Rosangela Requi 30 January 2013 (has links)
Em muitos países, os sistemas de radiologia computadorizada (CR) representam a maioria dos equipamentos usados em mamografia digital. Este estudo apresenta um método para a otimização da qualidade da imagem e da dose em mamografia digital CR para pacientes com mamas de espessuras entre 45 e 75. As espessuras das mamas foram simuladas com placas de polimetilmetacrilato (PMMA). Técnicas de exposição otimizadas (tensão (kV), produto corrente-tempo (mAs) e combinação alvo/filtro) foram definidas como aquelas que fornecem uma razão contraste-ruído (CNR) ideal, denominada CNR alvo, que permite atingir o limiar de contraste das imagens do detalhe de diâmetro de 0,10 mm no simulador CDMAM (versão 3.4 Artinis Medical Systems, Netherlands) com um padrão de Dose Glandular Média (DGM) aceitável. Os resultados foram utilizados para os ajustes do Controle Automático de Exposição (CAE) pela equipe de manutenção. Um estudo retrospectivo de dois grupos de pacientes (Grupo 1-antes do ajuste do CAE e Grupo 2- após o ajuste do CAE) foi realizado. Os parâmetros de exposição foram reproduzidos nos simuladores para a determinação da CNR, da DGM e do limiar de contraste. As imagens clínicas destes pacientes foram analisadas por três radiologistas especialistas em mamografia que responderam questões sobre as estruturas anatômicas, ruído e contraste em áreas de valores de pixels altos ou baixos, sobre nitidez e contraste da imagem. Os resultados mostram que o método proposto foi efetivo para todas as espessuras de mama avaliadas. O ajuste do CAE proporcionou a concentração de valores da CNR no Grupo 2 mais próximas ao CNR alvo e que, mesmo como aumento do nível de ruído nas imagens clínicas, as análises do CDMAM mostraram que não houve prejuízo na identificação do objeto de 0,10 mm de diâmetro. Finalmente, este estudo conclui que o uso dos CAE das unidades de raios X baseados em fornecer uma dose constante ao detector pode ocasionar algumas dificuldades para alguns sistemas CR operarem nas condições ótimas. / In many countries, computed radiography (CR) systems represent the majority of equipments used in digital mammography. This study presents a method for optimizing image quality and dose in CR mammography of patients with breast thicknesses between 45 to 75mm. The breast thicknesses were simulated with polymethylmetacrylate (PMMA). Optimazed exposure parameters ((voltage (kV), mA and time product (mAs) and target/filter combination)) was defined as giving an ideal contrast to noise ratio (CNR), defined as target CNR, to reach the threshold contrast of CDMAM (version 3.4) phantom (Artinis Medical Systems, Netherlands) images for acceptable mean glandular dose (MGD). These results were used for adjustments in the automatic exposure control (AEC) by the maintenance team. A retrospective study of two groups of patients (Group 1-before AEC adjustment and Group 2- after AEC adjustment) were done. The exposure parameters were reproduced in the phantoms to determine of CNR, MGD and threshold contrast. The clinical images of these patients were analyzed by three experienced radiologists who answered questions about anatomical structures, noise and contrast in low and high pixel value areas and image sharpness and contrast. The results showed that the proposed method was effective for all breast thickness evaluated. The AEC adjustment showed a concentration of CNR in Group 2 nearer of target CNR, and that the increasing of noise in clinical images, the CDMAM analysis showed that this level of noise did not disturb the detail of 0,1 mm diameter. Finally, this study also concluded that the use AEC of X rays unit based on constant dose to the detector may bring some difficulties to CR systems operate in optimal conditions.
34

Controle de qualidade, medição de dose glandular média e protocolo de rotina para tomossíntese digital mamária / Quality control, mean glandular dose and routine protocol in digital tomosynthesis breast

Messias, Pricila Cordeiro 22 August 2016 (has links)
No Brasil, o câncer de mama é o mais frequente e a principal causa de morte entre as mulheres, para o ano de 2016 foram estimados 57.960 mil novos casos. A Tomossíntese Digital Mamária (TDM) reduz os efeitos da sobreposição do tecido da mama, oferecendo uma melhor caracterização dos achados mamográficos e diminuindo a necessidade de incidências adicionais. A recente introdução da TDM na prática clínica requer manutenção dos requisitos de dose e qualidade da imagem, além de rotinas de Controle de Qualidade (CQ) e monitoração da Dose Glandular Média (DGM), e também uma equipe técnica qualificada para executar o procedimento. A prática de monitoração da qualidade da imagem e da dose de radiação é uma solução para assegurar continuamente a alta qualidade de exames de radiodiagnóstico. São poucos os estudos relacionados ao CQ em TDM no Brasil, e ainda não foram estabelecidos protocolos nacionais e internacionais específicos; sendo assim, os testes de CQ utilizados são baseados naqueles utilizados pela National Health Service Breast Screening Programme (NHSBSP), European Reference Organisation for Quality Assured Breast Screening and Diagnostic Service (EUREF), American Association of Physicists in Medicine (AAPM), Internacional Atomic Energy Agency (IAEA). Este estudo propõe e apresenta os resultados dos testes de CQ e DGM para mamografia e TDM, e um Protocolo de Rotina para exames de TDM. Os testes de CQ para TDM foram realizados conforme as recomendações do fabricante, da Portaria 2898/13 e de protocolos internacionais. O Protocolo de Rotina foi elaborado visando sanar as dúvidas mais frequentes da equipe técnica, assim como otimizar a qualidade do exame em sala. Para atestar a qualidade da imagem diagnóstica para todas as espessuras, foi realizado o teste de Qualidade de Imagem do simulador padrão do American College of Radiology (ACR). Na avaliação da DGM todos os valores obtidos para mamografia e TDM se mantiveram em conformidade com os limites de referência utilizados, exceto para a espessura de 20 mm em TDM. Para todos os outros testes de CQ, os resultados se mantiveram em conformidade com os limites de referência. Os resultados adquiridos nas avaliações reforçam a importância do controle de qualidade aplicado de forma adequada no processo de obtenção das imagens, assegurando baixa dose e boa qualidade da imagem, cumprindo o princípio ALARA. / In Brazil, breast cancer is the most common and the leading cause of death among women; in 2015, 57,120,000 new cases. Digital Breast Tomosynthesis (DBT) reduces the effects of overlapping breast tissue, offering a better characterization of mammographic findings and decreasing the need of additional views. The recent introduction of DBT in clinical practice requires, in order to maintain the dose requirements and image quality, aside from routine Quality Control (QC) procedures and monitoring the Mean Glandular Dose (MGD) also a qualified technical team to perform the procedure. The practice of monitoring the image quality and the radiation dose is a solution to continuously ensure high quality diagnostic radiology exams. Few studies related to CQ TDM in Brazil, and national and international specific protocols have not been established, Thus, QC tests used are based on those used by the National Health Service Breast Screening Programme (NHSBSP), European Reference Organization for Quality Assured Breast Screening and Diagnostic Service (EUREF), American Association of Physicists in Medicine (AAPM), International Atomic Energy Agency (IAEA). This study proposes and presents the results of the QC tests and DGM for mammography and TDM, and routine protocol for TDM tests. The QC tests for TDM were performed according to the manufacturer's recommendations, of Portaria 2898/13 and international protocols. The Routine Protocol was elaborated aiming to resolve the most frequent doubts of the technical team, as well as optimize the room examination. In order to certify the quality of the diagnostic image for all thicknesses, a imagine quality test from the standard simulator of American College of Radiology (ACR) was performed. In the DGM evaluation, all values mammography and TDM remained in accordance with the reference range used except for 20 mm TDM. For all other QC tests, the results remained in accordance with the reference limits. The results obtained in the assessments emphasize the importance of quality control applied properly in obtaining the imaging process, ensuring low dose and good image quality, fulfilling the ALARA principle.
35

Controle de qualidade, medição de dose glandular média e protocolo de rotina para tomossíntese digital mamária / Quality control, mean glandular dose and routine protocol in digital tomosynthesis breast

Messias, Pricila Cordeiro 22 August 2016 (has links)
No Brasil, o câncer de mama é o mais frequente e a principal causa de morte entre as mulheres, para o ano de 2016 foram estimados 57.960 mil novos casos. A Tomossíntese Digital Mamária (TDM) reduz os efeitos da sobreposição do tecido da mama, oferecendo uma melhor caracterização dos achados mamográficos e diminuindo a necessidade de incidências adicionais. A recente introdução da TDM na prática clínica requer manutenção dos requisitos de dose e qualidade da imagem, além de rotinas de Controle de Qualidade (CQ) e monitoração da Dose Glandular Média (DGM), e também uma equipe técnica qualificada para executar o procedimento. A prática de monitoração da qualidade da imagem e da dose de radiação é uma solução para assegurar continuamente a alta qualidade de exames de radiodiagnóstico. São poucos os estudos relacionados ao CQ em TDM no Brasil, e ainda não foram estabelecidos protocolos nacionais e internacionais específicos; sendo assim, os testes de CQ utilizados são baseados naqueles utilizados pela National Health Service Breast Screening Programme (NHSBSP), European Reference Organisation for Quality Assured Breast Screening and Diagnostic Service (EUREF), American Association of Physicists in Medicine (AAPM), Internacional Atomic Energy Agency (IAEA). Este estudo propõe e apresenta os resultados dos testes de CQ e DGM para mamografia e TDM, e um Protocolo de Rotina para exames de TDM. Os testes de CQ para TDM foram realizados conforme as recomendações do fabricante, da Portaria 2898/13 e de protocolos internacionais. O Protocolo de Rotina foi elaborado visando sanar as dúvidas mais frequentes da equipe técnica, assim como otimizar a qualidade do exame em sala. Para atestar a qualidade da imagem diagnóstica para todas as espessuras, foi realizado o teste de Qualidade de Imagem do simulador padrão do American College of Radiology (ACR). Na avaliação da DGM todos os valores obtidos para mamografia e TDM se mantiveram em conformidade com os limites de referência utilizados, exceto para a espessura de 20 mm em TDM. Para todos os outros testes de CQ, os resultados se mantiveram em conformidade com os limites de referência. Os resultados adquiridos nas avaliações reforçam a importância do controle de qualidade aplicado de forma adequada no processo de obtenção das imagens, assegurando baixa dose e boa qualidade da imagem, cumprindo o princípio ALARA. / In Brazil, breast cancer is the most common and the leading cause of death among women; in 2015, 57,120,000 new cases. Digital Breast Tomosynthesis (DBT) reduces the effects of overlapping breast tissue, offering a better characterization of mammographic findings and decreasing the need of additional views. The recent introduction of DBT in clinical practice requires, in order to maintain the dose requirements and image quality, aside from routine Quality Control (QC) procedures and monitoring the Mean Glandular Dose (MGD) also a qualified technical team to perform the procedure. The practice of monitoring the image quality and the radiation dose is a solution to continuously ensure high quality diagnostic radiology exams. Few studies related to CQ TDM in Brazil, and national and international specific protocols have not been established, Thus, QC tests used are based on those used by the National Health Service Breast Screening Programme (NHSBSP), European Reference Organization for Quality Assured Breast Screening and Diagnostic Service (EUREF), American Association of Physicists in Medicine (AAPM), International Atomic Energy Agency (IAEA). This study proposes and presents the results of the QC tests and DGM for mammography and TDM, and routine protocol for TDM tests. The QC tests for TDM were performed according to the manufacturer's recommendations, of Portaria 2898/13 and international protocols. The Routine Protocol was elaborated aiming to resolve the most frequent doubts of the technical team, as well as optimize the room examination. In order to certify the quality of the diagnostic image for all thicknesses, a imagine quality test from the standard simulator of American College of Radiology (ACR) was performed. In the DGM evaluation, all values mammography and TDM remained in accordance with the reference range used except for 20 mm TDM. For all other QC tests, the results remained in accordance with the reference limits. The results obtained in the assessments emphasize the importance of quality control applied properly in obtaining the imaging process, ensuring low dose and good image quality, fulfilling the ALARA principle.