• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • 1
  • Tagged with
  • 5
  • 5
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Bubble detection in Brazil’s stock market: application of the generalized superior augmented Dickey-Fuller test

Ferreira, Marcos Souza 28 June 2016 (has links)
Submitted by Marcos Souza Ferreira (mferreira@poli.ufrj.br) on 2016-07-27T13:57:40Z No. of bitstreams: 1 FERREIRA M - BUBBLE DETECTION IN BRAZILS STOCK MARKET.pdf: 405486 bytes, checksum: 54cd37d39ac7269f0a808b0e73addedb (MD5) / Rejected by Renata de Souza Nascimento (renata.souza@fgv.br), reason: Marcos, boa tarde Por gentileza, verificar a numeração das páginas. Está correto, elas aparecerem a partir da Introdução, porém, não deve se iniciar pela página 1. Por exemplo, se a Introdução é na página 11, incluir a partir da página 11. Em seguida submeter novamente o arquivo. Att on 2016-07-28T15:38:39Z (GMT) / Submitted by Marcos Souza Ferreira (mferreira@poli.ufrj.br) on 2016-07-28T16:49:04Z No. of bitstreams: 1 FERREIRA M - BUBBLE DETECTION IN BRAZILS STOCK MARKET_2.pdf: 684136 bytes, checksum: a1699da4f25b85c408c1bb37a9f00b99 (MD5) / Approved for entry into archive by Renata de Souza Nascimento (renata.souza@fgv.br) on 2016-07-28T16:58:52Z (GMT) No. of bitstreams: 1 FERREIRA M - BUBBLE DETECTION IN BRAZILS STOCK MARKET_2.pdf: 684136 bytes, checksum: a1699da4f25b85c408c1bb37a9f00b99 (MD5) / Made available in DSpace on 2016-07-28T17:28:22Z (GMT). No. of bitstreams: 1 FERREIRA M - BUBBLE DETECTION IN BRAZILS STOCK MARKET_2.pdf: 684136 bytes, checksum: a1699da4f25b85c408c1bb37a9f00b99 (MD5) Previous issue date: 2016-06-28 / Considering the importance of the proper detection of bubbles in financial markets for policymakers and market agents, we used two techniques described in Diba and Grossman (1988b) and in Phillips, Shi, and Yu (2015) to detect periods of exuberance in the recent history of the Brazillian stock market. First, a simple cointegration test is applied. Secondly, we conducted several augmented, right-tailed Dickey-Fuller tests on rolling windows of data to determine the point in which there’s a structural break and the series loses its stationarity.
2

Etude des perturbations du champ électromagnétique par un écoulement de métal liquide contenant une inclusion isolante / Perturbations of the electromagnetic field by a liquid metal flow containing an insulating inclusion

Guichou, Rafaël 30 April 2019 (has links)
Cette thèse se situe dans le cadre de la conception du réacteur nucléaire à caloporteur sodium ASTRID, actuellement à l'étude au CEA Cadarache. La mesure de vitesse du sodium liquide dans les boucles primaire et secondaire, ainsi que la détection de bulles, en cas de fuite par exemple, représentent un enjeu majeur pour le contrôle et la surveillance en fonctionnement du réacteur. Le caractère conducteur électrique du sodium liquide permet d'envisager l'utilisation de débitmètres à courants de Foucault, ou ECFM (pour Eddy Current Flow Meter) pour répondre à ces fonctions. Une précédente thèse réalisée par Mitlesh Kumar a permis de découpler le signal mesuré à l'ECFM relatif à la vitesse du métal, de celui relatif à la présence d'hétérogénéités dans le métal (telles que des bulles). L'objet de la présente thèse est de caractériser expérimentalement et analytiquement les effets de la vitesse et de la présence d'une inclusion isolante sur le signal mesuré, à partir d'écoulements modèles. Cette approche, complémentaire avec un certain nombre d'études en écoulement réel recensées dans la littérature, a pour objectif d'apporter un outil de compréhension physique au système. Deux dispositifs expérimentaux en métal liquide (galinstan) sont réalisés. Le premier dispositif représente un écoulement de galinstan en conduite cylindrique avec un champ de vitesse uniforme (écoulement piston), contenant une inclusion rigide électriquement isolante simulant une bulle. Le second dispositif expérimental est un écoulement en conduite de galinstan réel en l'absence d'inclusion. Les paramètres contrôlés sont la vitesse débitante du métal liquide (de 0.01 à 1 m/s), la taille et la position de l'inclusion (rayon entre 1 et 2.5 mm, profondeur entre 3 et 6 mm) et la fréquence (de 0.5 à 20 kHz). Le rayon de la conduite vaut 12.5 mm, et l'épaisseur de peau varie entre 2.4 et 15.3 mm sur cette plage de fréquence. Deux modèles théoriques, basés sur la résolution de l'équation d'induction du potentiel vecteur, sont en outre développés pour déterminer les effets de la vitesse et les effets de la présence de l'inclusion sur le signal mesuré. Dans les deux expériences, il est montré que le signal mesuré relatif à la vitesse du métal varie linéairement avec la vitesse et est maximal à une certaine fréquence (f = 2 kHz ici). Ces résultats correspondent à ceux du premier modèle théorique et montrent un bon accord avec la littérature. Dans la première expérience par ailleurs, le passage de l'inclusion à travers l'ECFM se manifeste par une oscillation du signal mesuré. Le comportement de l'oscillation est correctement décrit par le second modèle théorique dans la limite des basses fréquences (jusqu'à 2 kHz) : l'amplitude de l'oscillation est alors proportionnelle au volume de l'inclusion et suit une loi de puissance en f^2. Aux hautes fréquences, il est montré que l'amplitude et le déphasage du signal mesuré relatif à la présence de l'inclusion sont impactés de manière importante par la taille et la profondeur de l'inclusion. Un début de méthode inverse est développé à partir de ce résultat, pour déterminer la taille et la position de l'inclusion / This thesis is included in the conception of the prototype of Sodium Fast Reactor (SFR) ASTRID, currently studied in the CEA Cadarache. Velocimetry of liquid sodium in the primary andsecondary loops, and bubble detection in sodium (e.g. in case of leaks) represent a major issue for the control and oversight of the reactor. The electrical conductive property of liquid sodium allows to consider the use of Eddy Current Flow Meters (ECFM) for this purpose. A previous thesis realized by Mithlesh Kumar highlighted a decoupling of the signal measured with the ECFMrelative to the velocity, to the one relative to the presence of heterogeneities (such as bubbles). The object of the present thesis is to caracterize experimentally and analytically the effects of velocity and the effects of the presence of an insulating inclusion on the measured signal, thanks to modeled flows. This approach, complementary with most of the studies of real flows existing in the litterature, aims to give a tool for a physical comprehension of the system. Two experimental set-ups with liquid metal (galinstan) have been developed. The first set-up represent a galinstan flow in a cylindrical duct at uniform velocity (plug flow), advecting electrically insulating rigidinclusion simulating a bubble. The second experimental set-up is a galinstan flow in a cylindrical duct without inclusion. The controled parameters are the flow velocity (from 0.01 to 1 m/s), the size and location of the inclusion (radius from 1 to 2.5 mm, depth of 3 and 6 mm) and the frequency (from 0.5 to 20 kHz). The radius of the duct is equal to 12.5 mm, and the skin depth varies between 2.4 and 15.3 mm for this frequency range. Two theoretical models, based on the resolution of the induction equation of the vector potential, are moreover developed to determine velocity effects and inclusion effects on the measured signal. In both experimental studies, it is shown that the measured signal relative to the liquid metal velocity varies linearly with velocity and is maximal at a given frequency (f = 2 kHz here). These results are corresponding well with those of the first theoretical model and show a good agreement with litterature. Besides, in the first experimental study, the passage of the inclusion through the ECFM manifests itself by an oscillation of the measured signal. The behaviour of the oscillation is well described by the second theoretical model within the limit of low frequencies (up to 2 kHz) : the amplitude of the oscillation is then proportionnal to the inclusion volume and follows a power law in f^2. At high frequencies, it is shown that amplitude and phaseshift of the measured signal relative to the presence of an inclusion are highly impacted by inclusion size and depth. A first step of inverse method is developed from this result, in order to determine size and location of an inclusion.
3

Optimalizace vzduchování fotobioreaktoru za pomoci analýzy obrazu / Photobioreactor aeration optimization using image analysis

Hruška, Kryštof January 2021 (has links)
This diploma thesis summarizes the knowledge about microalgae, their use, cultivation methods and obstacles that prevent their wider use. In the practical part of the work, a device was designed, constructed, and programmed. This device can analyze the bubbles of the tubular photobioreactor and, based on the obtained data, control its aeration. The Python programming language was used to create the program and the OpenCV library was used to analyze the photographs. The bubble detection is based on the edge detection and the subsequent refinement. The data obtained from the analysis are displayed on the device screen and the data are also stored in a csv file. The discussion lists possible improvements and lessons learned during the creation of this device.
4

<b>INTEGRATED LOW-FREQUESNCY AND HIGH FREQUENCY SENSORS FOR SINGLE-CELL DETECTION</b>

Abdulrahman Nasser a Alghamdi (17537103) 03 December 2023 (has links)
<p dir="ltr">Cell polarity as defined by biologists is the cell ability to sense, determine its direction and orient itself in specific direction (e.g., front and back, top and bottom, and inside and outside). Recent studies have shown that loss of cell polarity at the tissue-level is a signature of a tumor. Detecting tumor cells based on their polarization, i.e., their electrical permittivity at the single-cell level could open the door for potential new diagnosing tools. Developing sensitive tools that are affordable and can perform fast reading is an after-sought goal. Currently, biochemical techniques are the adapted methods for research and analysis. These techniques include fluorescence-based, affinity-based, electrochemistry-based, and optical-based methods. The main disadvantages of these methods are their bulky size, and high cost due to the use of the complex pre-labeling and cannot handle small numbers of cells. On the other hand, biophysical sensing techniques for single cell focus on the whole cell intrinsic properties such as molecular compositions, volume, mass, electrical properties (i.e., conductivity and permittivity), mechanical properties. Biophysical sensing based on electrical methods would be non-invasive, fast, safe for the cells, and affordable. </p><p dir="ltr">In this thesis, novel sensors for single-cell detection are presented. Design, simulation, fabrication, and in some cases, experimental characterization of these proposed microfluidic sensors are discussed in details. The use of low and high frequency readouts for cell detection as well as the long-term goal of integration as a CMOS sensing platform are demonstrated. Detection and counting of air-bubbles on mm-sized RF ring resonator are demonstrated as a first proof of concept. Miniaturized RF ring resonator and co-planar-waveguide (CPW) devices that are integrated with microfluidic channels to characterize single-cells are then discussed. Furthermore, a novel CMOS capacitor sensor for cell detection is proposed for the first time. The idea of the proposed sensor is based on a perforated MIM capacitor that allows the detection of cells by a change in the dielectric constant of the capacitor perforated with a micro-channel.</p>
5

Magnetic flux distorsion in two-phase liquid metal flow / Étude d’une méthode de détection de gaz dans du sodium liquide par méthode électromagnétique pour les Réacteurs à Neutrons Rapides au Sodium (RNR Na)

Kumar, Mithlesh 23 March 2016 (has links)
Cette thèse se situe dans le cadre du projet ASTRID du CEA. La surveillance de la présence de gaz dans un RNR est importante pour son fonctionnement en toute sécurité. Cette thèse porte sur la détection et la caractérisation de présence de gaz par un débitmètre à distorsion de flux (DDF). Du point de vue technologique, l’objectif est d’évaluer la faisabilité de l’utilisation d’un DDF, et s’il est possible de mesurer le débit et le taux de vide simultanément avec un DDF. Du point de vue de la physique, le DDF mesure la perturbation du flux magnétique due aux courants de Foucault induits par l’hydrodynamique d’un écoulement de liquide conducteur. En présence de vide dans le conducteur, une nouvelle source de perturbation apparaît du fait de la modification, par le taux de vide, de la distribution du champ magnétique. En effet, la présence de vide agit sur les distributions locales de courants électriques dues au couplage des phénomènes d’induction et de forces de Lorentz. Notre objectif est de comprendre la nature de ces couplages et de proposer une méthode qui permette de caractériser la présence de vide à partir du signal de sortie du DDF, de mesurer le taux de vide et d’étudier la sensibilité de cette mesure aux variations des paramètres de l’écoulement et du champ électromagnétique (vitesse et pulsation, en particulier). Dans ce travail, des expériences spécifiques ont été développées pour étudier les effets de la vitesse, du taux de vide et de la pulsation du flux magnétique sur la réponse d’un DDF. Ces expériences modélisent un écoulement diphasique idéal (écoulement piston) consistant en une barre mobile d’aluminium contenant des trous et des cannelures pour simuler le taux de vide. Dans ces expériences la vitesse, le taux de vide et la pulsation sont parfaitement contrôlé et leur domaine de variations sont les suivants : 0<U<1 m/s pour la vitesse, 0< <6.9% pour le taux de vide et 1500<<12000 rad/s pour la pulsation (dans cette gamme de pulsations, on notera que la profondeur de pénétration du champ électromagnétique est de l’ordre de, mais plus petit que, le rayon du barreau d’aluminium). Une méthode d’ellipse-fitting appliqué au signal de sortie du DDF a été utilisée pour caractériser l’effet du taux de vide. Les résultats montrent que le DDF est sensible pour des fractions volumique de vide entre 0.3 % and 6.9% . En outre, la réponse aux variations de taux de vide est insensible à la vitesse du barreau. Cette technique est peu adaptée aux mesures des faibles taux de vide (< 0.1%). Une deuxième approche a été développée, sur la base de l’analyse du signal démodulé du DDF. Cette analyse s’appuie sur un modèle théorique du flux magnétique obtenu par un développement au 1er ordre par rapport à U et a. Ce modèle permet d’interpréter les résultats expérimentaux en termes de contributions de U et a au flux magnétique. Malgré le couplage fort entre l’induction Faraday et les forces de Lorentz, les résultats montrent que les contributions de U et alpha peuvent être séparées correctement pour des petites valeurs du nombre de Reynolds magnétique (Rem < 0.12), et de faible taux de vide ( < 6.9%). Un résultat très important est que la contribution de a sur le flux magnétique est insensible aux variations de vitesse dans cette gamme de Rem . De plus, l’effet de la géométrie du vide a été étudié pour deux configurations : cannelures et trous. Il a été observé que la géométrie du vide n’a pas d’effet sur les variations du flux magnétique avec a. Cette seconde approche est plus sensible aux variations de fraction volumique du vide que la méthode de l’ellipse-fitting. Enfin, des expériences préliminaires avec un liquide métallique (galinstan) contenant des perles de verre, ont été faites et ont montré une bonne sensibilité du signal du DDF avec la vitesse et le taux de vide. En conclusion, ce travail a montré qu’il est possible de mesurer simultanément un taux de vide et un débit pour la gamme de variations des paramètres étudiés. / A Generation IV Sodium cooled Fast Reactor (SFR) is being researched and developed at CEA, Cadarache France under the project named ASTRID. Monitoring gas presence in SFR is important with respect to its safe operation. In accordance with the principles of diversity, techniques based on different measurement principles have been proposed. This thesis concerns the detection and characterization of void using magnetic flux perturbation principle. An Eddy Current Flow Meter (ECFM) device is used for this purpose. From the technological point of view, the objective is to evaluate the feasibility of ECFM as a flow and/or void monitoring/characterizing device; and to determine which parameters are of interest and what are the precision of these measurements; and whether it is possible to measure the flow rate and void fraction simultaneously with the same ECFM device. From the physics point of view, the ECFM system involves the magnetic flux perturbation due to voids in the presence of Faraday induction and Lorentz force effects. Therefore ECFM integrated signal contains informations about the void, Faraday induction and Lorentz force effects based perturbation in magnetic flux and their couplings. Our objective is to understand the nature and extent of these couplings. Specific experiments have been developed to study the effects of flow velocity, void fraction and magnetic flux pulsations on the response of an ECFM. It consists in modeling the two-phase flow by a moving aluminium rod (plug flow) with holes and grooves to simulate voids. Flow velocity range of variation was 0<U<1 m/s, void fraction 0<<6.9% and pulsation 1500<<12000 rad/s (for this range of pulsations the electromagnetic skin depth is of order but smaller than the aluminium rod radius). An ellipse fitting method was proposed to analyze the output signal of the secondary coils. The results show that ECFM is sensitive to void fractions between 0.3 % and 6.9%. Furthermore, the response to void fraction is insensitive to the mean velocity of the twophase medium. A second approach based on demodulation analyses of the secondary coils output signal has been developed. We have proposed a theoretical model based on a first order expansion of magnetic flux in U and a. With this model it was possible to interpret the experimental results in terms of contributions of U and a. Despite the strong coupling between Faraday induction and Lorentz force effects, the results show that the contributions of U and a. can be well separated at low magnetic Reynolds number (Rem < 0.12) and low a values ( < 6.9%). A very important result is that the contribution of _ on magnetic flux is insensitive to variations of velocity in this range of Rem. Moreover, different geometries of void have been studied: grooves and holes. It was observed that the geometry of void do not change the variation of magnetic flux with a. This second approach revealed to be more sensitive to void fraction variations than ellipse fitting method. Finally, preliminary experiments with liquid metal galinstan with glass beads were done, which showed sensitivity of ECFM signal with velocity and void. In conclusion, this work has shown that ECFM can measure simultaneously void and velocity in the range of parameters studied, in particular 0.06%< < 6.9%.

Page generated in 0.0654 seconds