• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 354
  • 8
  • 4
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 373
  • 124
  • 80
  • 80
  • 69
  • 67
  • 52
  • 47
  • 46
  • 32
  • 32
  • 32
  • 29
  • 29
  • 28
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
101

Zeitgestalt - análise e performance do trio em sol menor de Francisco Braga / Zeitgestalt Análysis and Performance of Trio in G minor by Francisco Braga

Margarida Tamaki Fukuda 09 March 2009 (has links)
O presente trabalho pretende dar continuidade à pesquisa de Mestrado concluída em 2002 na PUC-SP, sobre um método de análise das Zeitgestalten, voltado para a performance musical. Tendo por base o livro Denken und spielen (Pensar e tocar), escrito pelo pianista e pedagogo alemão Prof. J. Uhde, em parceria com a filósofa e pianista Profa. Dra. R. Wieland (1989) pesquisou-se naquela época os fundamentos teóricos do método, tendo sido analisadas as Zeitgestalten de peças para piano solo. O projeto de Doutorado tem como objetivo principal, compreender os limites e aplicações deste procedimento metodológico na Prática Instrumental de Música de Câmara, não desenvolvido pelos autores. A obra escolhida para esta pesquisa foi escrita em 1930 por um importante compositor pertencente à História da Música Brasileira do final do século XIX e início do XX. Trata-se do Trio em sol menor para piano e cordas, de Francisco Braga, obra de representatividade dentro daquele período histórico. Após encontro com a Profa. Dra. R. Wieland, em janeiro de 2008, ocasião em que foram discutidos assuntos relacionados a Zeitgestalt em obras camerísticas, e analisada o 1º mov. do Trio em sol menor, o trabalho foi direcionado à escrita da tese e ao estudo analítico-interpretativo da obra, junto a um trio formado por jovens estudantes de música do curso de graduação, formado especialmente para este projeto. Pode-se dizer após esta investigação, que o método de Uhde e Wieland se aplica, sim, em repertório camerístico tendo trazido resultados bastante positivos. Faz parte também desta pesquisa, além da questão analítica-interpretativa, a questão editorial. / The present work extends the research presented for Masters concluded in 2002 at PUC-SP, on a method of analysis of Zeitgestalten towards musical performance. On that occasion it was carried out a study on the theoretical foundations of the method and the Zeitgestalten analysis of pieces for piano solo, based on the book Denken und spielen (Thinking and Play) written by the German pianist and pedagogue, Prof. J.Uhde, in partnership with the philosopher and pianist Prof. Doctor R. Wieland (1989). The actual project aims the understanding of the limits and applications of this methodological procedure in the Performance of Chamber Music, which is not developed by those authors. For that purpose the chosen musical work belongs to Francisco Braga, na important composer who lived between the end of the 19th century and the beginning of the 20th century and is part of the Brazilian Music History. The composition written in 1930 is the Trio in g minor for piano, violin and cello, a work of representativiness within that period of history. After meeting with Prof. Dr. R. Wieland in January 2008, when issues related to Zeitgestalt in Chamber Music works were discussed and the analysis of the first movement of the Trio in g minor was done, the work was directed towards the writing of the thesis and the interpretative-analytical study of it, with a trio constituted by young music students from the graduation course formed specifically for this project. Doubtless the method of Wieland and Uhde certainly applies to Chamber repertoire, and the results brought highly positive results. The work also includes, besides the analytical-interpretative question, the editorial matters results.
102

Caracterização e aplicação de duas câmaras de extrapolação em feixes padronizados de radiação X / Characterization and application of two extrapolation chambers in standard X radiation beams

Eric Alexandre Brito da Silva 31 March 2011 (has links)
As câmaras de extrapolação são câmaras de ionização com volume variável e são utilizadas principalmente como detectores de radiação beta. Neste trabalho foram caracterizadas duas câmaras de extrapolação, uma comercial da marca PTW, e uma outra desenvolvida no Laboratório de Calibração do IPEN, para aplicação como sistemas de referência em feixes de mamografia, radiodiagnóstico convencional e radioterapia. Os resultados obtidos nos testes de caracterização da resposta das câmaras de extrapolação: corrente de fuga, estabilidade de curto e médio prazos, determinação das correntes de saturação e das eficiências de coleção de íons, dependência angular e energética, mostram que estas câmaras de extrapolação podem ser utilizadas em dosimetria de feixes de radiação X de energias baixas. Os fatores de transmissão no tecido e os fatores de calibração foram também determinados para todas as qualidades de radiação citadas. Finalmente, foi estabelecido um procedimento de calibração de detectores de radiação em feixes padronizados de radiação X, utilizando as câmaras de extrapolação. / The extrapolation chambers are ionization chambers with variable volume, and they are mainly utilized as beta radiation detectors. In this work two extrapolation chambers were characterized, a commercial PTW extrapolation chamber and another extrapolation chamber developed at the Calibration Laboratory of IPEN, for application as reference systems in mammography, conventional diagnostic radiology and radiotherapy beams. The results obtained from the characterization tests of the chamber response: leakage current, short- and medium terms stability, determination of the saturation currents and the ion collection efficiencies, angular and energy dependence, show that these extrapolation chambers may be utilized for low-energy X radiation beam dosimetry. The transmission factors in tissue and the calibration factors were also determined for all cited radiation qualities. Finally, a procedure was established for calibration of radiation detectors in standard X radiation beams, using the extrapolation chambers.
103

Caracterização de uma câmara de ionização ar-livre em feixes diretos de raios X utilizados em mamografia / Characterization of a free-air ionization chamber in direct X-ray beams as used in mammography

Mateus Hilário de Lima 24 February 2014 (has links)
Neste trabalho foram realizados testes de estabilidade e de caracterização de uma câmara de ionização de ar-livre com cilindros concêntricos da marca Victoreen, modelo 481. Os testes foram feitos utilizando feixes diretos de mamografia como uma contribuição para a implantação desta câmara como sistema padrão primário para a grandeza kerma no ar. Os testes de caracterização realizados foram: curva de saturação, eficiência de coleção de íons, efeito de polaridade, linearidade da resposta com a taxa de kerma no ar e linearidade da resposta com a variação volumétrica. O teste de eficiência de coleção de íons possibilitou a determinação do fator de correção para recombinação iônica. A maioria dos testes realizados esteve em conformidade com os limites estabelecidos por normas internacionais. Foram obtidos os fatores de correção para atenuação de fótons no ar para as qualidades de mamografia com filtros de alumínio e molibdênio. Foram determinados também os fatores de correção para transmissão e espalhamento de fótons nas bordas do diafragma para as qualidades de mamografia com filtro de alumínio e para a qualidade padrão de mamografia com filtro de molibdênio. / At this work stability and characterization tests were undertaken on a Victoreen free-air ionization chamber, model 481. The tests were realized using direct X-ray beams as a contribuition for its establishment as a primary standard system of the quantity air kerma. The characterization tests were: saturation curve, ion collection efficiency, polarity effect, response linearity with the air kerma rate and response linearity with the chamber volume variation. The ion collection efficiency allowed the determination of the ion recombination factor. Most of the test results showed agreement with the limits established by international standards. Furthermore, the air attenuation factors for the mammography beams with aluminum and molybdenum filters were obtained. The factors for photon transmission and scattering at the diaphragm edges were also determined for mammography beams with aluminum filter and for the standard beam with molybdenum filter.
104

Estudo da exalação de radônio em placas e tijolos de fosfogesso de diferentes procedências / Study of radon exhalation from phosphogypsum plates and blocks from different origins

Lucas José Pereira da Costa 13 December 2011 (has links)
O fosfogesso é um resíduo da indústria de fertilizantes fosfatados que concentra radionuclídeos naturais. Neste trabalho foi estudada a taxa de exalação de 222Rn em placas e tijolos de fosfogesso, visando sua utilização na construção de residências. Para tanto, foram determinadas a taxa de exalação de 222Rn por meio da técnica da câmara de acumulação com detectores sólidos de traços nucleares (SSNTD) inseridos em uma câmara de difusão e a dose efetiva para um indivíduo habitando uma residência construída com esses materiais. A título de comparação foi também determinada a taxa de exalação teórica, por meio do modelo proposto pela UNSCEAR, a partir da concentração de 226Ra nas placas e tijolos de fosfogesso. A contribuição do revestimento na superfície dos materiais para a diminuição da taxa de exalação de radônio foi também avaliada. Foram estudados placas e tijolos fabricados com fosfogesso das empresas Bunge Fertilizantes, Ultrafertil e Fosfertil e tijolos fabricados com gesso comum. Os valores médios obtidos foram 0,19 0,06 Bq m-2 h-1, 1,3 0,3 Bq m-2 h-1 e 0,41 0,07 Bq m-2 h-1 para as placas fabricadas com fosfogesso proveniente das empresas Bunge, Ultrafertil e Fosfertil, respectivamente. Já para os tijolos de fosfogesso, os valores foram 0,11 0,01 Bq m-2 h-1, 1,2 0,6 Bq m-2 h-1, 0,47 0,15 Bq m-2 h-1, para o fosfogesso da Bunge, Ultrafertil e Fosfertil. O tijolo fabricado com gesso comum apresentou valor médio de 0,18 0,08 Bq m-2 h-1. As doses efetivas anuais para um indivíduo habitando uma residência construída como os tijolos ou placas de fosfogesso de qualquer uma das procedências ficaram abaixo do limite de dose efetiva para indivíduos do público de 1 mSva-1 estabelecido pela Comissão Internacional de Proteção Radiológica. / Phosphogypsum is a waste of the fertilizer industry that concentrates radionuclides. In this work, the 222Rn exhalation rate from phosphogypsum paltes and blocks from different origins used at dwellings construction was studied. The 222Rn exhalation rate was determined through the accumulation chamber technique with solid state nuclear track detectors (SSNTD). The effective dose for an individual living in a residence built with phosphogypsum based materials was evaluated. It also was calculated the 222Rn exhalation rate through the UNSCEAR model, from the 226Ra concentration in the materials, in order to compare the experimental results. It was evaluated the contribution of building component (paint) to the reduction of 222Rn exhalation rate. The plates and blocks were manufactured with phosphogypsum from Bunge Fertilizantes, Ultrafertil and Fosfertil. Blocks manufactured with ordinary gypsum was also evaluated. The average results obtained were 0.19 ± 0.06 Bq m-2 h-1, 1.3 ± 0.3 Bq m-2 h-1 and 0.41 ± 0.07 Bq m-2 h-1for plates manufactured with phosphogypsum from Bunge Fertilizer, Ultrafertil and Fosfertil, respectively. For the phosphogypsum blocks the values were 0.11 ± 0.01 Bq m-2 h-1, 1.2 ± 0.6 Bq m-2 h-1, 0.47 ± 0.15 Bq m-2 h-1, for Bunge, Ultrafertil and Fosfertil. The blocks manufactured with ordinary gypsum presented average value of 0.18 ± 0.08 Bq m-2 h-1. All phosphogypsum plates and blocks evaluated in this study presented effective dose for radon inhalation lower than the recommended value of 1mSv y1, the annual effective dose limit for public exposure by International Commission on Radiological Protection.
105

Desenvolvimento de câmaras de ionização especiais para controle de qualidade em mamografia / Development of special ionization chambers for a quality control program in mammography

Jonas Oliveira da Silva 20 May 2013 (has links)
A mamografia é um método de diagnóstico por imagem que utiliza radiação X. No controle de qualidade dos mamógrafos, as câmaras de ionização são usadas para verificar se os parâmetros de exposição das pacientes estão corretos. Contudo, as câmaras de ionização comerciais para dosimetria em mamografia representam alto custo para clínicas de pequeno e médio porte que desejam ter esse equipamento ou para profissionais que trabalham com controle de qualidade. Assim, a característica inovadora deste trabalho foi desenvolver câmaras de ionização para este fim. Neste trabalho foram projetadas, construídas e caracterizadas câmaras de ionização para feixes de radiação X, no intervalo de energia de mamografia. As câmaras de ionização foram caracterizadas em feixes padronizados de radiação X no LCI/IPEN. Os testes principais de caracterização das câmaras de ionização foram: curva de saturação, linearidade da resposta, dependência energética e angular. Os testes de estabilidade da resposta das câmaras de ionização também foram realizados, apresentando resposta dentro de 2,0 % para estabilidade em longo prazo. Os resultados dos demais testes foram em conformidade com normas internacionais. Essas câmaras de ionização foram ainda submetidas a testes de controle de qualidade de mamógrafos quanto à linearidade das taxas de kerma no ar, à determinação das camadas semirredutoras e das doses glandulares médias. Para a linearidade da taxa de kerma, os valores obtidos foram abaixo dos 10 %, como estabelecido em norma. A dose glandular determinada com as câmaras desenvolvidas apresentaram valores comparáveis com os da câmara de referência testada, com variação prevista em recomendações internacionais. / Mammography is an imaging method that uses X-rays. The use of ionization chambers in mammography quality control programs presents an essential role which is to verify whether the parameters of the patient exposure are correct. However, the commercial ionization chambers for dosimetry in mammography represent a high cost for small and medium size clinics that wish to have this equipment or for professionals that work with quality control programs. The innovative feature of this work was to develop ionization chambers for this purpose. In this work ionization chambers for X radiation beams in the mammography energy range were designed, constructed and characterized. The ionization chambers were tested in standard X radiation beams at the LCI/IPEN. The main characterization tests performed with the ionization chambers were: saturation curve, linearity of response, angular and energy dependence. The response stability tests of the ionization chambers were also conducted at the LCI, presenting results within 2.0 % for long-term stability. The results of the remaining tests are in accordance with international standards. These ionization chambers were also submitted to quality control tests of mammography equipment: linearity of the air kerma rates, determination of half-value layers and mean glandular doses. The results for air kerma rate linearity were less than 10 %, as recommended in international standards. The mean glandular dose obtained with the developed chambers presented values comparable to those of commercial ionization chambers tested, with an estimated variation within international standards.
106

Projeto, construção e caracterização de câmaras de ionização especiais para monitoração de feixes de radiação X / Design, construction and characterization of special ionization chambers for X radiation beams monitoring

Maíra Tiemi Yoshizumi 25 October 2010 (has links)
Os equipamentos de radiação X, por estarem ligados à rede elétrica, podem apresentar flutuações na intensidade de seus feixes de radiação. Essas variações na intensidade, podem, por sua vez, modificar a taxa de kerma no ar produzida por este feixe de radiação. Em um laboratório de calibração de instrumentos, onde são realizadas calibrações de diversos equipamentos detectores de radiação, utilizados principalmente em clínicas ou hospitais, essa possível variação na intensidade do feixe de radiação pode causar um erro na determinação da dose absorvida. As câmaras de ionização monitoras são utilizadas para verificar a constância da intensidade de feixes de radiação, e fornecer uma correção para possíveis oscilações. Neste trabalho foram projetadas, construídas e caracterizadas câmaras de ionização monitoras para feixes de radiação X. As câmaras de ionização desenvolvidas possuem formato inovador, anelar, com eletrodos de alumínio ou de grafite. Essas câmaras de ionização anelares apresentam a vantagem de não interferirem no feixe direto de radiação. Foi ainda construída uma câmara de ionização com volume duplo e eletrodos de grafite, similar à câmara de ionização monitora comercial utilizada no Laboratório de Calibração de Instrumentos do Instituto de Pesquisas Energéticas e Nucleares. Essas câmaras de ionização foram testadas em diversos feixes de radiação padronizados e seus desempenhos foram comparados aos de câmaras de ionização comerciais. Os resultados obtidos mostram que duas dentre as quatro câmaras de ionização desenvolvidas apresentaram desempenho comparável ao das câmaras de ionização comerciais testadas. Além de apresentarem bons resultados, as câmaras de ionização desenvolvidas foram feitas artesanalmente e utilizando materiais de baixo custo, que são facilmente encontrados no mercado. / X radiation equipment may show fluctuations in the radiation beam intensity, as they are connected to the power net. These intensity variations can, in turn, modify the air kerma rate produced by this radiation beam. In a calibration laboratory, where radiation detectors (from clinics and hospital services) are calibrated, variations in the radiation beam intensity may cause an error in the absorbed dose determination. The monitor ionization chambers are used to verify the radiation beam intensity constancy, and to provide a correction for possible fluctuations. In this work, monitor ionization chambers for X radiation beams were designed, assembled and characterized. The developed ionization chambers have an innovative design, ring-shaped, with aluminium or graphite electrodes. These ring-shaped ionization chambers have the advantage of not interfering in the direct radiation beams. A double-volume ionization chamber with graphite electrodes was also developed. This ionization chamber is similar to the commercial monitor ionization chamber used in the Calibration Laboratory of the Instituto de Pesquisas Energéticas e Nucleares. All developed ionization chambers were tested in several standardized radiation beams and their performances were compared with those of commercial ionization chambers. The results show that two of the four ionization chambers developed showed performance comparable to that of the commercial ionization chambers tested. Besides presenting good results, the ionization chambers were designed and manufactured using low cost materials, which are easily found on the Brazilian market.
107

Algoritmo para contagem de células do tipo fibroblastos NIH/3T3 em câmara de Neubauer utilizando processamento digital de imagens

Costa, Lucas Soares da 28 March 2017 (has links)
Submitted by Cristiane Chim (cristiane.chim@ucpel.edu.br) on 2018-08-30T12:05:38Z No. of bitstreams: 1 Lucas Soares da Costa.pdf: 6533559 bytes, checksum: 540c854aef17b6fb97cad699d5be5f0a (MD5) / Made available in DSpace on 2018-08-30T12:05:38Z (GMT). No. of bitstreams: 1 Lucas Soares da Costa.pdf: 6533559 bytes, checksum: 540c854aef17b6fb97cad699d5be5f0a (MD5) Previous issue date: 2017-03-28 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / From the perspective of systems biology, the cell is the main element of information integration. Therefore, understanding the cell in its context is the key to unraveling many of the still unknown mechanisms of life and certain pathologies. Despite increasing automation in clinical analysis laboratories, many of them still employ optical microscopes for some specific analyzes. When working with microorganisms, it is most often desired to determine the cell concentration of the prepared suspension. One of the most common ways of obtaining this estimate is by counting under the microscope, using a Neubauer Chamber, also known as a Hemacytometer or Count Chamber. Each microscope image can contain hundreds of cells to be counted. Performing the counting visually entails a very large inaccuracy and requires high time, which also increases the time to obtain the final estimate. The current state of scientific research in Brazil and other third world countries reflects the need for a device that is easily accessible and inexpensive for researchers. Thus, in view of the aforementioned reasons, the development of a mechanism that matches these expectations becomes indispensable. In view of this perspective, the objective of this study was consolidated in the development of an algorithm for cellular counting through the capture of images from the Neubauer chamber. This algorithm results in counting accuracy greater than 90 % when compared to manual counting, as well as reducing the time from approximately two minutes to less than one second of the algorithm. / Na perspectiva de biologia de sistemas, a célula é o elemento principal da integração de informações. Portanto, compreender a célula no seu contexto é a chave para desvendar muitos dos mecanismos ainda desconhecidos da vida e de certas patologias. Apesar da crescente automatização nos laboratórios de análises clínicas, muitos deles ainda empregam microscópios óticos para algumas análises específicas. Quando se trabalha com microorganismos, na maioria das vezes deseja-se determinar a concentração de células da suspensão preparada. Uma das formas mais comuns de se obter esta estimativa é através da contagem ao microscópio, utilizando-se uma Câmara de Neubauer, também conhecida como Hemacitômetro ou Câmara de Contagem. Cada imagem de microscópio pode conter centenas de células a serem contadas. Realizar a contagem de forma visual acarreta em uma imprecisão muito grande e requer tempo elevado, o que também aumenta o tempo para obter a estimativa final. A situação atual da pesquisa científica no Brasil e em outros países de terceiro mundo reflete a necessidade de um dispositivo de fácil acesso e baixo custo aos pesquisadores. Assim, diante dos motivos supracitados, o desenvolvimento de um mecanismo que corresponda essas expectativas, faz-se indispensável. Frente a essa perspectiva, o objetivo desse estudo consolidou-se no desenvolvimento de um algoritmo para contagem celular através da captura de imagens da câmara de Neubauer. Este algoritmo resulta em uma precisão na contagem superior a 90% quando comparado a contagem manual, como também, reduzir o tempo de aproximadamente dois minutos para menos de um segundo do algoritmo.
108

Junturas de palavras no português brasileiro cantado : estratégias para a execução e suas relações com a interpretação da canção /

Starling, Juliana de Carvalho. January 2018 (has links)
Orientador: Luiz Ricardo Basso Ballestero / Banca: Adriana Giarola Kayama / Banca: Joana Mariz de Sousa / Banca: Mônica Pedrosa de Pádua / Banca: Sandra Madureira / Resumo: A interpretação da canção de câmara brasileira exige refletir sobre elementos musicais e verbais, notados e não notados na partitura, que se relacionam diretamente com a emissão da voz cantada. O conhecimento sobre junturas de palavras é, assim, particularmente importante, pois se desdobra em diversas possibilidades de performance. Em uma perspectiva interdisciplinar, tópicos de fonética, fonologia e semântica, bem como os aspectos estilísticos, históricos e expressivos da performance vocal foram considerados para fornecer subsídios para a criação de estratégias de análise de junturas de palavras em peças vocais. A metodologia da pesquisa incluiu a análise de registros sonoros, realizada a partir do modelo da Teoria Fundamentada nos Dados. Demonstramos que a ideia da sílaba complexa transitória (SCT), formada pelos limites de vocábulos, pode contribuir para a identificação de fenômenos fonéticos e prosódicos que envolvem o texto e a música. Uma vez conhecidos as categorias e os fenômenos que se relacionam aos processos articulatórios, constatamos que a execução das junturas pode ser alterada, caso haja modificação em algum parâmetro envolvido: a respiração e a pausa, os ajustes do trato vocal (articulação), a intensidade, a altura, a duração e o timbre. / Abstract: The interpretation of a Brazilian Art Song requires us to speculate about musical and verbal elements, either notated on the score or not, which are directly related to the vocal production. The knowledge about the connection of words (junction, linkages) is thus particularly important because it unfolds into various performance possibilities. In an interdisciplinary perspective, topics on phonetics, phonology, and semantics and stylistic, historical and expressive aspects of vocal performance were considered in order to provide subsidies to create strategies to analyze the connection of words in vocal music. The methodology included the analysis of recordings, realized according to the Grounded Theory. We evidenced that the transient complex syllable (SCT), formed by the vocabulary limits, can contribute to the identification of phonetic and prosodic contents, involving text and music. Once differentiated as categories and processes related to articulatory processes, the results showed that the performance of the words linkages/junction can be changed, in case there is a modification in musical and vocal parameters, such as breath planning, musical rests, adjustments in the vocal tract (articulation), intensity, pitch, duration and timbre. / Doutor
109

Perfil de distribuição no rato de NPs de ouro com diferentes revestimentos

Morais, Tiago André Coutinho January 2010 (has links)
No description available.
110

Análise de um Sistema de Informação : a Câmara Municipal de Vila Nova de Ourém (do Liberalismo à Primeira República)

Ribeiro, Ana Margarida Pereira January 2009 (has links)
O presente relatório é produto de um estágio concretizado no Arquivo Histórico Municipal de Ourém, cujo objecto de estudo foi o Sistema de Informação "Câmara Municipal de Vila Nova de Ourém" durante o período liberal. A nossa estratégia de acção começõu por ser a identificação da estrutura, com correspondente levantamento dos orgãos que compunham este sistema de informação e as respectivas competências (com base na legislação da época), para poterormente podermos contextualizar as séries por eles produzidas. Elaborado o quadro de classificação, procedemos à descrição e à construção de instrumentos de acesso a essa informação. A par destas tarefas, levámos a cabo a construção de um guia, onde integrámos referências à documentação alusiva a Ourém e que se encontra dispersa por diversos arquivos. Por fim, deixámos algumas sugestões, que consideramos importantes para dinamização e difusão cultural do arquivo, uma vez que pensamos que as valências do arquivo extravasam a classificação, descrição e criação de pontos de acesso.

Page generated in 0.0442 seconds