21

A utilização e as implicações de cameras de video na rede Internet

Donati, Luisa Angelica Paraguai 28 July 2018 (has links)
Orientador: Gilberto dos Santos Prado / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Artes / Made available in DSpace on 2018-07-28T15:21:47Z (GMT). No. of bitstreams: 1 Donati_LuisaAngelicaParaguai_M.pdf: 11659763 bytes, checksum: bcf665c22a200433c6d97407804dc25e (MD5) Previous issue date: 1999 / Resumo: A crescente facilidade de acesso à rede Internet e a proliferação de dispositivos necessários para essa utilização cada vez mais amigáveis, permitem aos participantes, usuários, possibilidades de transformações das relações e interações com estas interfaces tecnológicas e seus produtos imagéticos e com eventuais parceiros também conectados na World Wíde Web. Este trabalho pretende pesquisar e refletir sobre as recentes utilizações e as novas possibilidades de criação, aprendizagem, entretenimento, em contextos que se valem do uso de câmeras de vídeo na World Wide Web. Estas câmeras acopladas aos computadores pessoais permitem a geração e a veiculação de imagens em tempo real na rede, transmitindo espaços físicos remotos e situações interpessoais que terminam por provocar experiências artísticas, educativas, científicas, em contextos partilhados com outros usuários da World Wide Web. Este trabalho pretende assim refletir e discutir sobre estas possibilidades de atuação, ação, dos usuários diante dessas imagens em direto veiculadas na rede / Abstract: The growing easiness of access to Internet and the proliferation of necessary devices for that use more and more friendly, that allow to the participants, users, possibilities of transformations of the relationships and interactions with these technological interfaces and their image products and with eventual partners also connected in World Wide Web. This work intends to research and discuss about the recent uses and the new possibilities of creation, learning, entertainment, in contexts mediated by the use of video cameras in the World Wide Web. These cameras are coupled to the personal computers and allow the production and transmission of live images in net, transmitting remote physical spaces and interpersonal situations that end up provoking artistic, educational, scientific experiences, in contexts shared with other users of the World Wide Web. This work intends to reflect and discuss about these possibilities of the users' performance/action before those live images transmitted in Web / Mestrado / Mestre em Multimeios
22

Uma proposta para avaliação do desempenho de câmaras PET/SPECT / A proposal for Evaluating the performance of PET/SPECT Cameras

Aoki, Suely Midori 11 December 2002 (has links)
A tomografia por emissão de pósitrons (\"Positron Emission Tomography\" - PET) é uma técnica para obtenção de imagens tomográficas em Medicina Nuclear que permite o estudo da função e do metabolismo do corpo humano em diversos problemas clínicos, através do uso de fármacos marcados por radionuclídeos emissores de pósitrons. As aplicações mais frequentes ocorrem em oncologia, neurologia e cardiologia, através da análise qualitativa e quantitativa dessas imagens. Atualmente, a PET é realizada de duas maneiras: através de sistemas constituídos por anéis formados por alguns milhares de detectores operando em coincidência, chamados de sistemas dedicados; ou com o uso de câmaras PET /SPECT, formadas por dois detectores de cintilação em coincidência, que também servem para estudos com radionuclídeos emissores de fóton único (\"Single Photon Emission Computed Tomography\" - SPECT). O desenvolvimento desses sistemas PET /SPECT tornou viáveis os estudos com a fluor-deoxiglicose, [18 ANTPOT. F]-FDG, um fármaco marcado com 18 ANTIPOT. F (emissor de pósitrons com 109 minutos de meia-vida física), para um número grande de clínicas e hospitais, principalmente por estes serem de uma tecnologia economicamente mais acessível que os realizados com a PET dedicada. Neste presente trabalho, desenvolveu-se uma metodologia para caracterizar e avaliar um sistema PET /SPECT com dois detectores de cintilação e dispositivo com duas fontes pontuais de Cs-137, destinado à obtenção das imagens de transmissão para a correção de atenuação dos fótons. Ela se baseia em adaptações dos testes convencionais de câmaras SPECT, descritos no IAEA TecDoc - 602 - 1991 (\"lnternational Atomic Energy Agency\" - IAEA), e de sistemas PET dedicados, publicados no NEMA NU 2- 1994 (\"National Electrical Manufacturers Association\"NEMA). O resultado foi organizado em forma de roteiros que foram testados em uma câmara da ADAC Laboratories/Philips, a VertexlM - Plus EPIClMJMCDlM - AC, instalada no Serviço de Radioisótopos do lnCor - HCFMUSP (Instituto do Coração - Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo). Esta câmara foi a primeira instalada no Brasil e está sendo utilizada, predominantemente, para estudos oncológicos e de viabilidade miocárdica. O radiofármaco utilizado na obtenção das imagens foi a [18F]-FDG, fornecida regularmente pelo IPEN/CNEN-SP (Instituto de Pesquisas Energéticas e Nucleares/Comissão Nacional de Energia Nuclear - São Paulo), e a reconstrução tomográfica foi realizada com o software próprio do sistema, utilizando-se os parâmetros padrão dos protocolos clínicos. Foram utilizadas fontes pontuais suspensas no ar para as medidas de resolução espacial transversal e lineares imersas na água para as de fração de espalhamento e sensibilidade. Na avaliação da sensibilidade, uniformidade, taxa de eventos verdadeiros, taxa de eventos aleatórios e tempo morto do sistema eletrônico, foram feitas imagens de um simulador físico construído especialmente para o presente trabalho, a partir das instruções da publicação NEMA NU 2 - 1994 para sistemas PET dedicados. A acurácia da correção de atenuação foi verificada através das imagens do simulador físico citado com a inserção de três cilindros de densidades diferentes: água, ar e Teflon. Os roteiros deste trabalho poderão servir de guia para Programas de Controle e Garantia de Qualidade e avaliação da performance de sistemas PET /SPECT com dois detectores de cintilação em coincidência. A implantação destes roteiros pelos centros clínicos que utilizam este tipo de equipamento aumentará a qualidade e a confiabilidade nas imagens resultantes, assim como na sua quantificação. / Positron emission tomography, PET, is a Nuclear Medicine technique that allows the study of human body\'s function and metabolism in many clinical problems, with the help of pharmaceuticals labeled with positron emitters. The most frequent applications occur in oncology, neurology and cardiology, through qualitative and quantitative analysis of these images. Currently, PET is performed in two manners: by using dedicated systems, consisted of rings of thousands of detectors operating in coincidence; or with the use of PET /SPECT cameras, formed by two scintillation detectors in coincidence, which are also used in SPECT studies (single photon emission tomography). The development of PET /SPECT systems made possible the studies with fluor-deoxiglucose, [18F]-FDG, a pharmaceutical labeled with 18F (positron emitter with 109 minutes physical half-life), for a large number of clinics and hospitals, mainly due to their economical accessibility when compared to the dedicated PET studies. In this present work, a method was developed for characterizing and evaluating a PET /SPECT system with two scintillation detectors and device with two point sources of 137Cs, designed to obtain the transmission images for the photon attenuation correction. lt is based on adaptations of the conventional tests of SPECT cameras, described in IAEA TecDoc - 602 - 1991 (\"international Atomic Energy Agency \" - IAEA), and those for dedicated PET systems, published in NEMA NU 2 - 1994 (\"National Electrical Manufacturers Association \" - NEMA). The results were organized in a set of testing protocols and tested in the ADAC Laboratories/Philips camera, the VertexlM - Plus EPIClM/MCDlM - AC, installed in the Radioisotopes Service of lnCor - HCFMUSP (Instituto do Coração - Hospital das clínicas da Faculdade de Medicina da Universidade de São Paulo). This camera was the first one installed in Brazil and is being used, predominantly, for oncological studies and miocardial viability. The radiopharmaceutical used was [18F]-FDG, supplied regularly by IPEN/CNEN-SP (Instituto de Pesquisas Energéticas e Nucleares I Comissão Nacional de Energia Nuclear - São Paulo), and the tomographic reconstruction was performed with the system software, using the standard parameters of the clinical protocols. Point sources suspended in air were used in the measurements of spatial resolution and linear sources immersed in water for scattering fraction and sensitivity measurements. In the evaluation of sensitivity, uniformity, true events, random events and dead time of the electronic system, a phantom was constructed specifically for the present work, from the instructions of NEMA NU 2 - 1994 for dedicated PET systems. The accuracy of the attenuation correction was verified from the images of the phantom with three inserts of different densities: water, air and Teflon. The resultant protocols can serve as a guideline for Programs of Quality Control and Assurance, as well as for the evaluation of the performance of PET /SPECT systems with two scintillation detectors in coincidence. lf implemented by clinical centers that use this type of equipment, it will enhance the quality and confidence of the resulting images, as well as their quantification.
23

Engine combustors economical efficiency in terms of NOx emissions.

Eduardo de Marchi Furlan 05 May 2008 (has links)
Aviation industry has grown significantly in the past years and is forecasted to continue its growing. Running in parallel, environment concerns became more evident and are beginning to drive industry's and everyone's will. The technological development of aeronautical engines and mainly, new engine combustors technologies, have reached successful levels at the end of last century and they are expected to keep on improving their low emission and fuel consumption levels at mid and long-term basis. On the other hand, unfortunately, only technological improvements won't be sufficient to address environmental concerns. In the last 10 years, a "polluter pays" principle was raised in aviation market, to address the NOx high concentrations in terms of local air quality, mainly at big airports proximity. It has turned into a competitive advantage and economical benefit to less polluter aircrafts, at the same time "green" and environmental friendly measures are being most considered.
24

Uma proposta para avaliação do desempenho de câmaras PET/SPECT / A proposal for Evaluating the performance of PET/SPECT Cameras

Suely Midori Aoki 11 December 2002 (has links)
A tomografia por emissão de pósitrons (\"Positron Emission Tomography\" - PET) é uma técnica para obtenção de imagens tomográficas em Medicina Nuclear que permite o estudo da função e do metabolismo do corpo humano em diversos problemas clínicos, através do uso de fármacos marcados por radionuclídeos emissores de pósitrons. As aplicações mais frequentes ocorrem em oncologia, neurologia e cardiologia, através da análise qualitativa e quantitativa dessas imagens. Atualmente, a PET é realizada de duas maneiras: através de sistemas constituídos por anéis formados por alguns milhares de detectores operando em coincidência, chamados de sistemas dedicados; ou com o uso de câmaras PET /SPECT, formadas por dois detectores de cintilação em coincidência, que também servem para estudos com radionuclídeos emissores de fóton único (\"Single Photon Emission Computed Tomography\" - SPECT). O desenvolvimento desses sistemas PET /SPECT tornou viáveis os estudos com a fluor-deoxiglicose, [18 ANTPOT. F]-FDG, um fármaco marcado com 18 ANTIPOT. F (emissor de pósitrons com 109 minutos de meia-vida física), para um número grande de clínicas e hospitais, principalmente por estes serem de uma tecnologia economicamente mais acessível que os realizados com a PET dedicada. Neste presente trabalho, desenvolveu-se uma metodologia para caracterizar e avaliar um sistema PET /SPECT com dois detectores de cintilação e dispositivo com duas fontes pontuais de Cs-137, destinado à obtenção das imagens de transmissão para a correção de atenuação dos fótons. Ela se baseia em adaptações dos testes convencionais de câmaras SPECT, descritos no IAEA TecDoc - 602 - 1991 (\"lnternational Atomic Energy Agency\" - IAEA), e de sistemas PET dedicados, publicados no NEMA NU 2- 1994 (\"National Electrical Manufacturers Association\"NEMA). O resultado foi organizado em forma de roteiros que foram testados em uma câmara da ADAC Laboratories/Philips, a VertexlM - Plus EPIClMJMCDlM - AC, instalada no Serviço de Radioisótopos do lnCor - HCFMUSP (Instituto do Coração - Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo). Esta câmara foi a primeira instalada no Brasil e está sendo utilizada, predominantemente, para estudos oncológicos e de viabilidade miocárdica. O radiofármaco utilizado na obtenção das imagens foi a [18F]-FDG, fornecida regularmente pelo IPEN/CNEN-SP (Instituto de Pesquisas Energéticas e Nucleares/Comissão Nacional de Energia Nuclear - São Paulo), e a reconstrução tomográfica foi realizada com o software próprio do sistema, utilizando-se os parâmetros padrão dos protocolos clínicos. Foram utilizadas fontes pontuais suspensas no ar para as medidas de resolução espacial transversal e lineares imersas na água para as de fração de espalhamento e sensibilidade. Na avaliação da sensibilidade, uniformidade, taxa de eventos verdadeiros, taxa de eventos aleatórios e tempo morto do sistema eletrônico, foram feitas imagens de um simulador físico construído especialmente para o presente trabalho, a partir das instruções da publicação NEMA NU 2 - 1994 para sistemas PET dedicados. A acurácia da correção de atenuação foi verificada através das imagens do simulador físico citado com a inserção de três cilindros de densidades diferentes: água, ar e Teflon. Os roteiros deste trabalho poderão servir de guia para Programas de Controle e Garantia de Qualidade e avaliação da performance de sistemas PET /SPECT com dois detectores de cintilação em coincidência. A implantação destes roteiros pelos centros clínicos que utilizam este tipo de equipamento aumentará a qualidade e a confiabilidade nas imagens resultantes, assim como na sua quantificação. / Positron emission tomography, PET, is a Nuclear Medicine technique that allows the study of human body\'s function and metabolism in many clinical problems, with the help of pharmaceuticals labeled with positron emitters. The most frequent applications occur in oncology, neurology and cardiology, through qualitative and quantitative analysis of these images. Currently, PET is performed in two manners: by using dedicated systems, consisted of rings of thousands of detectors operating in coincidence; or with the use of PET /SPECT cameras, formed by two scintillation detectors in coincidence, which are also used in SPECT studies (single photon emission tomography). The development of PET /SPECT systems made possible the studies with fluor-deoxiglucose, [18F]-FDG, a pharmaceutical labeled with 18F (positron emitter with 109 minutes physical half-life), for a large number of clinics and hospitals, mainly due to their economical accessibility when compared to the dedicated PET studies. In this present work, a method was developed for characterizing and evaluating a PET /SPECT system with two scintillation detectors and device with two point sources of 137Cs, designed to obtain the transmission images for the photon attenuation correction. lt is based on adaptations of the conventional tests of SPECT cameras, described in IAEA TecDoc - 602 - 1991 (\"international Atomic Energy Agency \" - IAEA), and those for dedicated PET systems, published in NEMA NU 2 - 1994 (\"National Electrical Manufacturers Association \" - NEMA). The results were organized in a set of testing protocols and tested in the ADAC Laboratories/Philips camera, the VertexlM - Plus EPIClM/MCDlM - AC, installed in the Radioisotopes Service of lnCor - HCFMUSP (Instituto do Coração - Hospital das clínicas da Faculdade de Medicina da Universidade de São Paulo). This camera was the first one installed in Brazil and is being used, predominantly, for oncological studies and miocardial viability. The radiopharmaceutical used was [18F]-FDG, supplied regularly by IPEN/CNEN-SP (Instituto de Pesquisas Energéticas e Nucleares I Comissão Nacional de Energia Nuclear - São Paulo), and the tomographic reconstruction was performed with the system software, using the standard parameters of the clinical protocols. Point sources suspended in air were used in the measurements of spatial resolution and linear sources immersed in water for scattering fraction and sensitivity measurements. In the evaluation of sensitivity, uniformity, true events, random events and dead time of the electronic system, a phantom was constructed specifically for the present work, from the instructions of NEMA NU 2 - 1994 for dedicated PET systems. The accuracy of the attenuation correction was verified from the images of the phantom with three inserts of different densities: water, air and Teflon. The resultant protocols can serve as a guideline for Programs of Quality Control and Assurance, as well as for the evaluation of the performance of PET /SPECT systems with two scintillation detectors in coincidence. lf implemented by clinical centers that use this type of equipment, it will enhance the quality and confidence of the resulting images, as well as their quantification.
25

Desenvolvimento de uma metodologia para calibração de câmaras de ionização de placas paralelas em feixes de raios X de energia baixa em termos de dose absorvida em água / Development of a methodology for calibration of parallel plate ionization chambers for X-ray beams of low energy in terms of absorbed dose to water

Oliveira, Camila Trindade de 10 December 2015 (has links)
O objetivo deste trabalho foi estabelecer uma metodologia de calibração em termos de dose absorvida na água para câmaras de ionização de placas paralelas a serem utilizadas em feixes de radiação X de energia baixa (10 kV a 100 kV) para fins terapêuticos. Atualmente, no Brasil nenhum laboratório de calibração está oferecendo este tipo de serviço. Para o estabelecimento desta metodologia de calibração foram utilizadas duas câmaras de ionização PTW modelos 23344. Ambas as câmaras foram caracterizadas e testadas qualitativamente segundo recomendações de normas internacionais. Os testes de caracterização realizados foram: a medição da taxa de dose mínima efetiva, a curva de saturação, a eficiência da coleção de íons, a resposta quanto ao efeito da polaridade e a linearidade da câmara com a resposta. Os testes de controle de qualidade aplicados foram: estabilidade em curto e longo prazos, fuga de corrente sem irradiação, fuga de corrente após-irradiação e tempo de estabilização. Para a implantação da metodologia, foram estabelecidas as qualidades de radiação de T-10 a T-100, seguindo as recomendações do código de prática da AIEA. Desta forma, foi possível determinar a grandeza de referência, dose absorvida na água, utilizando-se as duas câmaras de ionizações e em todas as qualidades estabelecidas. / The objective of this study was to establish a calibration methodology in terms of absorbed dose to water for parallel plate ionization chambers to be used in low energy X rays beams (10kV to 100kV) for therapy purposes. Currently, in Brazil no calibration laboratory is offering this type of service. In order to establish this calibration methodology was used two ionization chambers PTW models 23344. Both chambers were characterized and tested qualitatively according to recommendations of international standards. The characterization tests performed were: measuring the effective minimum dose rate, the saturation curve, the efficiency of ions collection, polarity effect and the linearity of the ionization chamber with the response. The quality control tests applied were: stability in the short and long term, leakage current without irradiation, leakage current after irradiation and settling time. For the implementation of the methodology, the radiation qualities the T- 10 to T-100 were established, following the recommendations of the IAEA code of practice. Thus, it was possible to determine the magnitude of reference absorbed dose in water, using the two ionization chambers in the all established qualities.
26

Desenvolvimento de um sistema de referência para determinação do equivalente de dose pessoal e da constância de feixes de radiação X / Development of a reference system for the determination of the personal dose equivalent and the constancy of X-ray beams

Vivolo, Vitor 09 February 2006 (has links)
Um sistema de referência para determinação do equivalente de dose pessoal, HP (10), e um programa de controle da qualidade de sistemas geradores de raios X utilizados em radioproteção inclui a verificação periódica da constância dos feixes de raios X empregados na calibração de instrumentos medidores de radiação em laboratórios de calibração de instrumentos. Neste trabalho foram desenvolvidas duas câmaras de ionização de placas paralelas inseridas em objetos simuladores de tronco humano. Uma das câmaras de ionização possui eletrodo coletor de grafite, para a medida do equivalente de dose pessoal; a segunda câmara de ionização foi confeccionada com eletrodo coletor de alumínio para, juntamente com a primeira câmara de ionização, formarem um sistema Tandem. A dependência energética diferente da resposta das duas câmaras de ionização é que permite a formação do sistema Tandem, que apresenta grande utilidade na verificação da constância de feixes de radiação X. Foram ainda implantados feixes padronizados de radiação X de energias médias (48 keV a 118 keV), nível radioproteção, por meio do desenvolvimento de uma metodologia dosimétrica e da análise dos parâmetros físicos destes feixes. As câmaras desenvolvidas foram testadas em relação às suas características operacionais e foram calibradas em feixes de radiação X, níveis radioproteção, radiodiagnóstico, mamografia e radioterapia, e ainda em campos de radiação gama, seguindo as recomendações internacionais. Apresentaram bom desempenho. Foi estabelecido o procedimento da determinação do equivalente de dose pessoal, Hp (10). / A reference system for the determination of the personal dose equivalent, HP (10), and a quality control program of X-ray equipments used in radioprotection require the periodic verification of the X-ray beams constancy. In this work, two parallel-plate ionization chambers were developed with inner electrodes of different materials, and inserted into PMMA slab phantoms. One ionization chamber was developed with inner carbon electrodes and the other with inner aluminium electrodes. The two ionization chambers can be used as a Tandem system. The different energy response of the two ionization chambers allowed the development of the Tandem system that is very useful for the checking of the constancy of beam qualities. Standard intermediary energy X-ray beams (from 48 keV to 118 keV), radioprotection level, were established through the development of a dosimetric methodology and the analysis of their physical parameters. The ionization chambers were studied in relation to their operational characteristics, and they were calibrated in X-ray beams (radioprotection, diagnostic radiology, mammography and radiotherapy levels) in accordance to international recommendations. They presented good performance. The determination procedure of personal dose equivalent, HP (10), was established.
27

Desenvolvimento e caracterização de câmaras de ionização especiais para feixes de tomografia computadorizada / Development and characterization of special ionization chambers for computed tomography beams

Castro, Maysa Costa de 02 May 2016 (has links)
O uso de Tomografia Computadorizada (CT) para procedimentos de imagiologia vem crescendo cada vez mais devido aos avanços da tecnologia dos equipamentos de CT, que permitem a obtenção de imagens com melhor resolução do que por outras técnicas, sendo consequentemente responsável pelo aumento da dose de radiação no paciente durante o procedimento. Isso acarretou uma maior preocupação com as doses recebidas pelos pacientes que se submetem a esse tipo de exame. Para a realização da dosimetria de feixes de CT, o instrumento mais utilizado é a câmara de ionização do tipo lápis, pois este dosímetro apresenta uma resposta uniforme ao feixe de radiação incidente em todos os ângulos. A câmara convencional que se encontra disponível no mercado apresenta um comprimento de volume sensível de 10 cm; entretanto, alguns estudos têm mostrado que esse dosímetro tem subestimado os valores de dose. Portanto, neste trabalho optou-se por desenvolver no Laboratório de Calibração de Instrumentos do Instituto de Pesquisas Energéticas e Nucleares (LCI-IPEN/CNEN) duas câmaras de ionização, fazendo uso de materiais nacionais de baixo custo, com comprimentos de volume sensível de 10 cm e 30 cm. A caracterização destas câmaras foi realizada e os resultados se apresentaram dentro dos limites recomendáveis internacionais. Como uma aplicação, as câmaras desenvolvidas, juntamente com uma câmara comercial, foram testadas em um tomógrafo clínico. As câmaras de ionização desenvolvidas foram analisadas de maneira completa, para os seus possíveis usos. / The use of computed tomography (CT) for imaging procedures is growing due to advances in the CT equipment technology, because they allow the obtention of images with better resolution than through other techniques. Therefore, they are responsible for increasing the dose radiation of patients during the procedure. This fact led to a greater concern about the doses received by patients who undergo this type of examination. To perform the dosimetry in CT beams, the most widely used instrument is the pencil type ionization chamber, because this dosimeter has a uniform response to the incident radiation beam for all angles. The conventional ionization chamber, which is available on the market, has a sensitive volume length of 10 cm; however, some studies have shown that this dosimeter has underestimated the dose values. Therefore, in this study two ionization chambers with sensitive volume lengths of 10 cm and 30 cm, making use of low cost national materials, were developed at the Calibration Laboratory of Instruments (LCI-IPEN/CNEN). The characterization of these chambers was performed, and the results were obtained within the international recommended limits. As an application, the developed ionization chambers and a commercial chamber were tested in a clinical tomographer. The developed ionization chambers were analyzed in a complete way for their possible uses.
28

Investigação da formação do poluente NOX em chamas turbulentas sem prée-mistura.

Cristiane Aparecida Martins Andraus 00 December 2003 (has links)
O presente trabalho apresenta uma investigação experimental sobre o comportamento da espécie poluente NOx em chamas turbulentas sem pré mistura. Com intuito de se identificar as espécies químicas relevantes, ou de combinações entre estas, efetuou-se análise de sensibilidade utilizando pacote de cinética química CHEMKIN. Do trabalho experimental consta a implementação de um modelo laboratorial de uma câmara de combustão para chamas sem pré mistura, a otimização de algoritmo dedicado de reconstrução tomográfica em ambientes axi-simétricos e calibração do sistema ótico. Gás natural foi utilizado como combustível. O queimador utilizado é do tipo com chamas piloto, possuindo jato principal rodeado por 12 orifícios de chama piloto. Medidas intrusivas foram realizadas com sonda de amostragem de gases no interior da chama, termopar de fio fino de Pt/PtRh13% e anemômetro de fio quente. As medidas de velocidade foram comparadas com as obtidas com modelo de turbulência comprimento de mistura. Medidas de intensidade luminosa dos radicais CH, CN e C2 foram obtidas com câmaras CCD e os resultados foram avaliados após aplicação da técnica de reconstrução de imagens a partir de suas projeções.
29

Caracterização do escoamento de uma bancada de testes de combustores supersônicos alimentada por ar viciado.

Valéria Serrano Faillace Oliveira Leite 17 September 2006 (has links)
Para o desenvolvimento dos estudos da combustão supersônica está sendo montada no INPE (Instituto Nacional de Pesquisas Espaciais), em parceria com o IEAv (Instituto de Estudos Avançados), uma bancada de testes do tipo diretamente-conectada, para ensaios de combustores supersônicos. Esta bancada, junto com o túnel de choque hipersônico e o lançador hipersônico de massa, existentes no IEAv, formam o conjunto dos três equipamentos para ensaios em solo de aerotermodinâmica, necessários para a pesquisa e o desenvolvimento de motores aspirados do tipo "scramjets" ("supersonic combustion ramjets") e para testes de aerodinâmica interna e externa de modelos reduzidos de veículos hipersônicos. A bancada é formada basicamente por uma câmara de combustão, conhecida como gerador de ar viciado, acoplada a um bocal supersônico, cuja função é simular as condições do escoamento de ar atmosférico atrás de ondas de choque cônicas ou oblíquas que se formam em frente a veículos voando com velocidades hipersônicas. As características principais deste escoamento são de temperaturas elevadas, obtidas no gerador de ar viciado por combustão, e de velocidades supersônicas, obtidas no bocal supersônico. Para que a bancada funcione realmente como um equipamento de ensaios é necessário se ter o controle sobre as condições do escoamento de teste na saída da mesma. Assim surgiu a necessidade de se fazer uma avaliação completa do escoamento no interior desta bancada para se conhecer todos os fenômenos envolvidos no processo e obter a relação entre as condições do escoamento na entrada da câmara de combustão do gerador de ar viciado, as quais podem ser manipuladas, e as condições do escoamento de teste na saída do bocal supersônico que devem ser simuladas. A caracterização completa do escoamento no interior da bancada foi feita, neste trabalho, em três partes: a primeira é o estudo do escoamento cônico considerando o ar atmosférico, para a obtenção das condições do vôo real que devem ser simuladas, a segunda é a avaliação do processo de combustão no interior do gerador de ar viciado para a obtenção das condições de temperatura desejadas na saída da câmara de combustão e a terceira é o estudo do escoamento através do bocal supersônico convergente-divergente para a obtenção das condições de velocidade do ar viciado já aquecido a serem geradas na saída da bancada. Com o conhecimento obtido neste trabalho é possível controlar e sintonizar as condições de ensaio desejadas na saída da bancada de testes de combustão supersônica através somente da variação das vazões dos reagentes na entrada da câmara de combustão do gerador de ar viciado.
30

Detecção de instabilidades termoacústicas em câmaras de combustão do Tipo RQL para aplicação em turbinas a gás

Dener Silva de Almeida 03 July 2007 (has links)
O objetivo do seguinte trabalho é um novo modelo de câmara de combustão do tipo RQL ("Rich-Quench-Lean" na língua inglesa) para turbinas a gás. A combustão acontece em duas fases; a primeira com deficiência de oxidante ou rica em combustível, e a segunda é pobre em combustível. Esta estrutura de combustão permite a conciliação de baixas emissões de NOx e produtos de combustão de oxidação parcial, como monóxido de carbono, hidrocarbonetos não queimados e fuligem. A idéia dos combustores RQL tradicionais é a injeção estagiada de combustíveis através da câmara, criando algumas regiões de combustão desfavoráveis à formação do NOx. Mas no novo conceito aqui proposto, essas condições não favoráveis à formação do NOx são alcançadas através do controle da dinâmica da mistura entre os reagentes no interior da câmara, favorecendo algumas vantagens em relação ao processo RQL tradicional. Entretanto, para a combustão pobre na câmara secundária, dependendo dos parâmetros de operação, algumas oscilações acústicas ocorrem. Portanto, o presente trabalho trata da influência desses parâmetros operacionais: razão de equivalência, número de Reynolds do jato de combustível, número de "swirl", e razão comprimento/diâmetro da câmara primária (L/D), sobre as instabilidades acústicas. Os resultados mostram que aumentando o número de "swirl", e reduzindo o número de Reynolds do jato combustível, as oscilações de combustão podem ser atenuadas. Além disso, a mais alta razão L/D investigada foi 3, e para esta situação bons resultados foram observados para atenuação de instabilidades. Apesar das dificuldades para entender o complexo fenômeno de instabilidade de combustão, este trabalho apresenta algumas recomendações para controlar as oscilações em câmaras de combustão do tipo RQL para turbinas a gás.