• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Estudo tomográfico do encéfalo de cães dolicocefálicos, mesaticefálicos e branquicefálicos clinicamente sadios

Doiche, Danuta Pulz [UNESP] 01 August 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:23:41Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-08-01Bitstream added on 2014-06-13T19:09:45Z : No. of bitstreams: 1 doiche_dp_me_botfmvz.pdf: 1123328 bytes, checksum: 8e1dbfd7effb20988189cb5e55ffe74f (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / A Tomografia Computadorizada (TC), juntamente com a Ressonância Magnética, são modalidades de diagnóstico por imagem avançadas, consideradas de escolha para a avaliação do sistema nervoso, por fornecerem imagens livres de sobreposições e detectarem pequenas diferenças de densidade tecidual. Dentro de qualquer estudo, o conhecimento das possíveis formas de apresentação de cada estrutura e a determinação do limite entre o fisiológico e o alterado são fundamentais para um estudo preciso. O presente trabalho teve como objetivo a descrição dessas variações nas imagens tomográficas do encéfalo, no que diz respeito aos ventrículos laterais e atenuação do parênquima encefálico e cerebelar entre os grupos aqui estipulados (grupo dolicocefálico composto por cães pastores Alemães, grupo mesaticefálico composto por Rottweilers e grupo braquicefálico compostos por cães da raça Boxer) e assim enriquecer a avaliação cerebral à TC e minimizar erros de interpretação. Foram detectadas diversas diferenças individuais e entre os grupos à avaliação qualitativa. Quantitativamente, houve diferença da altura ventricular entre os braquicefálicos e os demais, mostrando que ainda não é possível apenas uma faixa de valores da altura ventricular comum a todos os cães, e que, para as raças braquicefálicas o valor da razão da altura ventricular e encefálica até 25% pode servir como limite superior nos animais hígidos. Os valores de atenuação finais na fase pré-contraste são compatíveis com trabalhos anteriores, o bulbo olfatório e o cerebelo apresentaram-se diferentes estatisticamente em relação aos demais locais. A única raça que teve nas fases simples e contrastada diferenças estatísticas em todos os locais foram os animais do grupo B / Computed tomography (CT) along with Magnetic Ressonance Imaging (MRI) are diagnostic imaging modalities of advanced, considered choice for the evaluation of the nervous system, for providing free images overlap and detect small differences in tissue density. Within any study, knowledge of the possible forms of presentation of each structure and determining the limit between physiological and change are fundamental to a precise study. This study aimed to describe these variations in the tomographic images of the brain, with respect to the lateral ventricles and attenuation of brain parenchyma and cerebellum between the groups set forth herein (dolichocephalic group composed of German shepherd dogs, a group composed of rottweilers and mesaticephalic brachycephalic group consisting of Boxer dogs) and thus enrich the evaluation of brain CT and minimize misunderstandings. We detected several differences between individuals and groups in the qualitative assessment of the aspects mentioned. Quantitatively, there were differences between the ventricular height between brachycephalic and others, showing that it is not possible just a strip of ventricular height values common to all dogs, and that for brachycephalic breeds the value of 25% can serve as upper limit in healthy animals. The final attenuation values in the pre-contrast are consistent with previous works, the olfactory bulb and cerebellum were different statistically when compared to other locations. The only race that was simple and contrasted phases statistical differences in all sites were the animals in group B
2

Estudo tomográfico do encéfalo de cães dolicocefálicos, mesaticefálicos e branquicefálicos clinicamente sadios /

Doiche, Danuta Pulz. January 2011 (has links)
Orientador: Luiz Carlos Vulcano / Banca: Masao Iwasaki / Banca: Rogério Martins Amorim / Resumo: A Tomografia Computadorizada (TC), juntamente com a Ressonância Magnética, são modalidades de diagnóstico por imagem avançadas, consideradas de escolha para a avaliação do sistema nervoso, por fornecerem imagens livres de sobreposições e detectarem pequenas diferenças de densidade tecidual. Dentro de qualquer estudo, o conhecimento das possíveis formas de apresentação de cada estrutura e a determinação do limite entre o fisiológico e o alterado são fundamentais para um estudo preciso. O presente trabalho teve como objetivo a descrição dessas variações nas imagens tomográficas do encéfalo, no que diz respeito aos ventrículos laterais e atenuação do parênquima encefálico e cerebelar entre os grupos aqui estipulados (grupo dolicocefálico composto por cães pastores Alemães, grupo mesaticefálico composto por Rottweilers e grupo braquicefálico compostos por cães da raça Boxer) e assim enriquecer a avaliação cerebral à TC e minimizar erros de interpretação. Foram detectadas diversas diferenças individuais e entre os grupos à avaliação qualitativa. Quantitativamente, houve diferença da altura ventricular entre os braquicefálicos e os demais, mostrando que ainda não é possível apenas uma faixa de valores da altura ventricular comum a todos os cães, e que, para as raças braquicefálicas o valor da razão da altura ventricular e encefálica até 25% pode servir como limite superior nos animais hígidos. Os valores de atenuação finais na fase pré-contraste são compatíveis com trabalhos anteriores, o bulbo olfatório e o cerebelo apresentaram-se diferentes estatisticamente em relação aos demais locais. A única raça que teve nas fases simples e contrastada diferenças estatísticas em todos os locais foram os animais do grupo B / Abstract: Computed tomography (CT) along with Magnetic Ressonance Imaging (MRI) are diagnostic imaging modalities of advanced, considered choice for the evaluation of the nervous system, for providing free images overlap and detect small differences in tissue density. Within any study, knowledge of the possible forms of presentation of each structure and determining the limit between physiological and change are fundamental to a precise study. This study aimed to describe these variations in the tomographic images of the brain, with respect to the lateral ventricles and attenuation of brain parenchyma and cerebellum between the groups set forth herein (dolichocephalic group composed of German shepherd dogs, a group composed of rottweilers and mesaticephalic brachycephalic group consisting of Boxer dogs) and thus enrich the evaluation of brain CT and minimize misunderstandings. We detected several differences between individuals and groups in the qualitative assessment of the aspects mentioned. Quantitatively, there were differences between the ventricular height between brachycephalic and others, showing that it is not possible just a strip of ventricular height values common to all dogs, and that for brachycephalic breeds the value of 25% can serve as upper limit in healthy animals. The final attenuation values in the pre-contrast are consistent with previous works, the olfactory bulb and cerebellum were different statistically when compared to other locations. The only race that was simple and contrasted phases statistical differences in all sites were the animals in group B / Mestre
3

Validação da técnica de angiotomografia helicoidal cerebral em cães hígidos

Rodriguez Hurtado, Diana Milena [UNESP] 11 July 2013 (has links) (PDF)
Made available in DSpace on 2014-08-13T14:50:46Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-07-11Bitstream added on 2014-08-13T18:00:40Z : No. of bitstreams: 1 000756751_20150731.pdf: 236798 bytes, checksum: 9b75b0cebfd8612cc949578b65a89f35 (MD5) Bitstreams deleted on 2015-08-03T12:20:55Z: 000756751_20150731.pdf,. Added 1 bitstream(s) on 2015-08-03T12:22:17Z : No. of bitstreams: 1 000756751.pdf: 892335 bytes, checksum: 952dae187bd640e40a8e14dec77be389 (MD5) / Desenvolveu-se a técnica de angiotomografia helicoidal como ferramenta para obter referências de normalidade do suprimento sanguíneo cerebral em cães sadios. O presente trabalho foi realizado em 17 animais, sendo 8 adultos jovens da raça pointer e 9 adultos sem raça definida; machos e fêmeas que apresentaram exames clínico- neurológicos e laboratoriais dentro da normalidade. Realizaram-se imagens simples e com meio de contraste iodado (MCI) não iônico injetado na veia cefálica esquerda, e foram feitas reconstruções multiplanares (MPR). Foi possível evidenciar a maioria das artérias que formam o circulo arterial cerebral, alem de algumas variações anatômicas como a presencia de uma artéria intercarotidea direita e esquerda em 3 cães dos 17 animais, e ausência do ramo direito da artéria cerebral rostral em outros 3 animais, demonstrando assim que a angiotomografia helicoidal é um exame seguro e rápido que pode ser aplicado na rotina tomográfica de cães para correta visualização do suprimento sanguíneo encefálico. Avaliou-se também o efeito do MCI não iônico a uma dose de 900 mg Iodo/kg, no rim utilizando-se ultrassonografia (US) e correlacionou-se com os valores de ureia e creatinina antes e após sua administração. Não foram visibilizadas alterações do parênquima renal em nenhum dos animais. Os valores de creatinina após a injeção do contraste permaneceram dentro da normalidade, porém os valores da ureia apresentaram aumento significativo, Assim, estudos ultrassonográficos correlacionados com exames de laboratório devem ser realizados em maior número de cães para determinar segurança e acurácia dos MCI não iônicos / Developed the technique of helical angitomography as a tool to get references from normal blood supply of the brain in healthy dogs. The present study was performed in 17 animals, 8 young adults breed pointer and 9 adult mixed breed; males and females with clinical, neurological and laboratory normal exams. There were simple images and nonionic iodinated contrast media (ICM) IV, injected into the left cephalic vein; were made multiplanar reconstructions (MPR). It was possible to demonstrate the major arteries that make up the arterial polygon of Willis, in addition some anatomical variations as the presence of an artery intercarotid right and left in 3 of 17 animals, and absence of the right branch of the rostral cerebral artery in other 3 animals, demonstrating that the helical angitomography is a safe and fast examination that can be applied in dogs routine tomographic for correct visualization of the cerebral blood supply. We also evaluated the effect of nonionic MCI at a dose of 900 mg Iodine/kg, in the kidney through ultrasound (U.S.) and correlated with the values of urea and creatinine before and after administration. No changes were seen in any of the renal parenchyma. Creatinine values after MCI remained within the normal range, however the values of urea showed on increase significant statistically, therefore ultrasound studies should be conducted to correlated with laboratory testing on a larger number of dogs to determine safety and accuracy of MCI
4

Validação da técnica de angiotomografia helicoidal cerebral em cães hígidos /

Rodriguez Hurtado, Diana Milena. January 2013 (has links)
Orientador: Maria Jaqueline Mamprim / Coorientador: Luiz Carlos Vulcano / Banca: Cibele Figueira Carvalho / Banca: Amalia Agut Giménez / Resumo: Desenvolveu-se a técnica de angiotomografia helicoidal como ferramenta para obter referências de normalidade do suprimento sanguíneo cerebral em cães sadios. O presente trabalho foi realizado em 17 animais, sendo 8 adultos jovens da raça pointer e 9 adultos sem raça definida; machos e fêmeas que apresentaram exames clínico- neurológicos e laboratoriais dentro da normalidade. Realizaram-se imagens simples e com meio de contraste iodado (MCI) não iônico injetado na veia cefálica esquerda, e foram feitas reconstruções multiplanares (MPR). Foi possível evidenciar a maioria das artérias que formam o circulo arterial cerebral, alem de algumas variações anatômicas como a presencia de uma artéria intercarotidea direita e esquerda em 3 cães dos 17 animais, e ausência do ramo direito da artéria cerebral rostral em outros 3 animais, demonstrando assim que a angiotomografia helicoidal é um exame seguro e rápido que pode ser aplicado na rotina tomográfica de cães para correta visualização do suprimento sanguíneo encefálico. Avaliou-se também o efeito do MCI não iônico a uma dose de 900 mg Iodo/kg, no rim utilizando-se ultrassonografia (US) e correlacionou-se com os valores de ureia e creatinina antes e após sua administração. Não foram visibilizadas alterações do parênquima renal em nenhum dos animais. Os valores de creatinina após a injeção do contraste permaneceram dentro da normalidade, porém os valores da ureia apresentaram aumento significativo, Assim, estudos ultrassonográficos correlacionados com exames de laboratório devem ser realizados em maior número de cães para determinar segurança e acurácia dos MCI não iônicos / Abstract: Developed the technique of helical angitomography as a tool to get references from normal blood supply of the brain in healthy dogs. The present study was performed in 17 animals, 8 young adults breed pointer and 9 adult mixed breed; males and females with clinical, neurological and laboratory normal exams. There were simple images and nonionic iodinated contrast media (ICM) IV, injected into the left cephalic vein; were made multiplanar reconstructions (MPR). It was possible to demonstrate the major arteries that make up the arterial polygon of Willis, in addition some anatomical variations as the presence of an artery intercarotid right and left in 3 of 17 animals, and absence of the right branch of the rostral cerebral artery in other 3 animals, demonstrating that the helical angitomography is a safe and fast examination that can be applied in dogs routine tomographic for correct visualization of the cerebral blood supply. We also evaluated the effect of nonionic MCI at a dose of 900 mg Iodine/kg, in the kidney through ultrasound (U.S.) and correlated with the values of urea and creatinine before and after administration. No changes were seen in any of the renal parenchyma. Creatinine values after MCI remained within the normal range, however the values of urea showed on increase significant statistically, therefore ultrasound studies should be conducted to correlated with laboratory testing on a larger number of dogs to determine safety and accuracy of MCI / Mestre

Page generated in 0.0709 seconds