• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • 1
  • Tagged with
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Método teórico-experimental para el cálculo de patrones de luz propagados en el ojo humano

Pérez Rodríguez, Jorge 10 December 2004 (has links)
No description available.
2

Diseño, fabricación y control de calidad de lentes intraoculares multifocales

Remón Martín, Laura 05 November 2012 (has links)
El mercado de lentes intraoculares (LIOs) está creciendo de manera espectacular en los últimos años debido al auge de cirugía de cataratas. La mayoría de las lentes implantadas en la actualidad son monofocales diseñadas simplemente para compensar la visión de lejos del paciente. Sin embargo, existen otros tipos de lentes denominadas multifocales (LIOMs) que proporcionan buena visión tanto de lejos como de cerca y suponen una alternativa prometedora en pacientes de más de 50 años para la compensación de la presbicia. En el mercado existen gran disparidad de diseños multifocales, cada uno con sus ventajas e inconvenientes, lo que evidencia que la LIOM que ofrece las mejores prestaciones todavía no ha sido diseñada. En esta Tesis se presentan resultados de diseño, fabricación y evaluación de la calidad óptica de un nuevo tipo de LIOMs, con geometría fractal, que presenta una mayor profundidad de foco y una menor aberración cromática con respecto a las que actualmente se encuentran en el mercado. Para la evaluación de la calidad óptica de las LIOMs propuestas se han desarrollado expresamente dos dispositivos experimentales basados en las especificaciones de la Norma UNE ISO 11979-2. Las medidas de calidad óptica obtenidas con los nuevos diseños de LIOMs fractales han sido comparadas con la obtenidas para algunos modelos de LIOMs comerciales, demostrando que las lentes propuestas presentan una calidad óptica comparable con las mismas. Además, se presentan medidas subjetivas de calidad óptica obtenidas en ojos reales, las cuales podrían ser de utilidad cuando se comience con los ensayos clínicos en sujetos operados de cirugía de cataratas. / Remón Martín, L. (2012). Diseño, fabricación y control de calidad de lentes intraoculares multifocales [Tesis doctoral]. Editorial Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/17703 / Palancia
3

Calidad óptica del ojo humano en función de la edad

Guirao Piñera, Antonio 17 December 1998 (has links)
Se ha estudiado la calidad óptica del ojo en función de la edad para entender mejor el envejecimiento del sistema visual humano. Se ha construido un sistema experimental de registro de imágenes, adaptado a un entorno clínico, para medir la función de transferencia (MTF) ocular, y se ha desarrollado un procedimiento computacional para obtener las aberraciones ópticas de la córnea. Se han realizado medidas en una población de 60 sujetos distribuidos en tres grupos de edad (20-30 años, 40-50 años y 60-70 años), y en un grupo de pacientes implantados con lente intraocular. La MTF media ocular empeora de cada grupo de edad al siguiente, y las aberraciones corneales tienden a aumentar. La calidad óptica del ojo humano se reduce progresivamente con la edad; la córnea es parcialmente responsable de esa reducción. La calidad óptica en pacientes con lente intraocular es similar a la media de los sujetos mayores normales. / The optical quality of the eye was studied as a function of age to better understand the aging process in the human visual system. An experimental imaging system, adapted to a clinical environment, was constructed to measure the ocular modulation transfer function (MTF). A computational procedure was developed to obtain the optical aberrations of the cornea. Measurements were performed in a population of 60 subjects within three age groups (20-30 years, 40-50 years, and 60-70 years), and in a group of 20 patients implanted with intraocular lenses. The average MTF declines as age increases from young to middle and older groups. Corneal aberrations tends to increase with age. Optical quality of the human eye progressively deteriorates with age. The cornea may partially explain the reduction of optical performance of the complete eye. The average image quality in patients with intraocular lenses was similar to the average of normal older subjects.
4

Wave aberrations in ophthalmic progressive power lenses and impact on visual quality. / Aberraciones en lentes oftálmicas de potencia progresiva y su impacto en la calidad visual.

Villegas Ruiz, Eloy Ángel 27 November 2009 (has links)
Las lentes progresivas (LP) para gafas es una solución muy extendida para la presbicia, ya que proporcionan una visión continua a todas las distancias debido a un cambio progresivo de potencia. En este trabajo se han medido las aberraciones de frente de onda espacialmente resueltas y la calidad visual en estas lentes. Además del astigmatismo que aumenta periféricamente, también se han encontrado pequeños valores de aberraciones de tercer orden, coma y trefoil, que producen un bajo deterioro de la calidad óptica y visual. El logaritmo de métricas sobre la PSF del sistema lente con ojo son las que mejor predicen la agudeza visual. Durante la primera semana de adaptación, no se aprecia una mejora significativa de la agudeza visual a través de distintas zonas de las LPs. Al comparar diferentes LPs, las aberraciones, principalmente el astigmatismo, se comporta como un colchón de agua, que se puede mover pero no eliminar. / Progressive lenses (PL) are designed to provide continuous vision at all distances by means a progressive change in spherical power from upper to lower zones. In this thesis, we measure the spatially resolved aberrations and the visual quality of PLs. In addition to astigmatism, third order aberrations, coma and trefoil, are also found in the PLs, but the impact of these aberrations on visual performance is limited. The logarithm of metrics on the PSF of the entire system eye plus PL are the parameters that best predict the visual acuity. There is not a significant improvement of visual acuity through the different zones of the PLs during the first week of adaptation. The current designs of PLs are somehow similar to a waterbed, with the aberrations, mainly astigmatism, being the water: they can be moved but they cannot be eliminated.

Page generated in 0.0755 seconds