• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 4
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Investigation of Planar Channeling Radiation on Diamond and Quartz Crystals at Electron Energies between 14 and 34 MeV and Probing the Influence of Ultrasonic Waves on Channeling Radiation

Azadegan, Behnam 15 January 2008 (has links) (PDF)
The first measurements of CR at the Radiation source ELBE of the Forschungszentrum Dresden-Rossendorf have been performed in the fall of 2003, where the most important attempt for an application of CR in radiobiological research was the optimization of its yield and spectral line width as well. Since diamond single crystals have been found to probably be the most suitable ones for an intense CR production because of their outstanding properties to withstand rather high average electron currents, a first measurement series was directed to the studying of the dependence of the yield of planar CR on the thickness of the diamond crystal.
2

Investigation of Planar Channeling Radiation on Diamond and Quartz Crystals at Electron Energies between 14 and 34 MeV and Probing the Influence of Ultrasonic Waves on Channeling Radiation

Azadegan, Behnam 15 November 2007 (has links)
The first measurements of CR at the Radiation source ELBE of the Forschungszentrum Dresden-Rossendorf have been performed in the fall of 2003, where the most important attempt for an application of CR in radiobiological research was the optimization of its yield and spectral line width as well. Since diamond single crystals have been found to probably be the most suitable ones for an intense CR production because of their outstanding properties to withstand rather high average electron currents, a first measurement series was directed to the studying of the dependence of the yield of planar CR on the thickness of the diamond crystal.
3

Establishment of the Physical and Technical Prerequisites for the Determination of the Relative Biological Effectiveness of Low-energy Monochromatic X-rays / Etablierung der physikalischen und technischen Voraussetzungen für die Bestimmung der relativen biologischen Wirksamkeit niederenergetischer, monochromatischer Röntgenstrahlung

Lehnert, Anna 15 February 2006 (has links) (PDF)
Low-energy X-rays in the range 10 - 50 keV have a wide application. One important application in radiological diagnostics is mammography, whereas, in radiotherapy, they are used for irradiation of superficial tumours, in brachytherapy and photon activation therapy. The importance of soft X-rays for fundamental radiobiological research is based on the fact, that all species of ionizing radiation produce a wide spectrum of secondary electrons, mainly responsible for the primary damage to be transformed into an observable radiobiological effect. By variation of the primary soft X-ray energy, a variation in the secondary electron spectra and therefore in the local energy deposition is provided. However, up to now no definitive conclusions about the relative biological effectiveness (RBE) of soft X-rays can be made due to its dependence on the photon energy, biological endpoint and dose range and the consequent large spread of the published data. The superconducting electron linear accelerator of high brilliance and low emittance (ELBE) at the Forschungszentrum Rossendorf with an electron energy up to about 40 MeV is used, among all, to generate X-rays in a wide energy range. One method for production of intensive, quasi-monochromatic X-rays in the energy range 10 - 100 keV tunable in energy, is by channeling of electrons in a perfect crystal. This X-ray source has many advantages over the most widespread X-ray source, which is the X-ray tube. Although the physical basis of the channeling effect has been previously investigated, the feasibility of an X-ray source based on channeling radiation (CR) for radiobiological studies has been for the first time theoretically and experimentally studied and a dedicated CR source built and optimised in the frame of this thesis. CR has been theoretically characterised in order to estimate its applicability for radiobiological studies. A good agreement between the theoretical predictions and the measured data has been found. The intrinsic properties of the CR source have led to the conclusion that monochromatisation is necessary. A monochromator based on HOPG mosaic crystals, was designed and manufactured. The dosimetrical methods have been investigated at the CR source as well as at an X-ray tube. Absolute dose measurements using an ionisation chamber and spectral dose distribution determination using semiconductor detectors have been performed. In addition, an unconventional system based on thermally stimulated exoelectron emission (TSEE) detectors, allowing to measure dose in a small volume and in the real cell environment has been tested and has proven itself appropriate in a variable dose range and in a liquid environment, in cases where reproducible laboratory conditions are provided. The biological endpoints clonogenic cell survival and micronucleus induction have been optimised for two established cell lines. The human mammary epithelial cells MCF-12A have been chosen due to the importance of RBE of soft X-rays for determination of risk from mammography. On the other hand, the use of the widespread mouse fibroblast cell line NIH/3T3 allows to compare the results with previously published data. The influence of the specific irradiation procedure at ELBE on the control level of cell survival and micronucleus induction has been tested and an irradiation system was developed and constructed. In addition, the RBE for soft X-rays was determined by X-ray tube irradiation at the Medical Department of Technische Universität Dresden. The RBE of 10 kV and 25 kV X-rays relative to 200 kV X-rays was determined. The RBE was found to be in the range from 1.0 to 1.4, depending on the used radiation quality, cell line and the biological endpoint, in agreement with previously published data for the same radiation qualities. These results confirm that systematical studies of RBE dependence on photon energy at the ELBE CR source are necessary and feasible.
4

Establishment of the Physical and Technical Prerequisites for the Determination of the Relative Biological Effectiveness of Low-energy Monochromatic X-rays

Lehnert, Anna 24 October 2005 (has links)
Low-energy X-rays in the range 10 - 50 keV have a wide application. One important application in radiological diagnostics is mammography, whereas, in radiotherapy, they are used for irradiation of superficial tumours, in brachytherapy and photon activation therapy. The importance of soft X-rays for fundamental radiobiological research is based on the fact, that all species of ionizing radiation produce a wide spectrum of secondary electrons, mainly responsible for the primary damage to be transformed into an observable radiobiological effect. By variation of the primary soft X-ray energy, a variation in the secondary electron spectra and therefore in the local energy deposition is provided. However, up to now no definitive conclusions about the relative biological effectiveness (RBE) of soft X-rays can be made due to its dependence on the photon energy, biological endpoint and dose range and the consequent large spread of the published data. The superconducting electron linear accelerator of high brilliance and low emittance (ELBE) at the Forschungszentrum Rossendorf with an electron energy up to about 40 MeV is used, among all, to generate X-rays in a wide energy range. One method for production of intensive, quasi-monochromatic X-rays in the energy range 10 - 100 keV tunable in energy, is by channeling of electrons in a perfect crystal. This X-ray source has many advantages over the most widespread X-ray source, which is the X-ray tube. Although the physical basis of the channeling effect has been previously investigated, the feasibility of an X-ray source based on channeling radiation (CR) for radiobiological studies has been for the first time theoretically and experimentally studied and a dedicated CR source built and optimised in the frame of this thesis. CR has been theoretically characterised in order to estimate its applicability for radiobiological studies. A good agreement between the theoretical predictions and the measured data has been found. The intrinsic properties of the CR source have led to the conclusion that monochromatisation is necessary. A monochromator based on HOPG mosaic crystals, was designed and manufactured. The dosimetrical methods have been investigated at the CR source as well as at an X-ray tube. Absolute dose measurements using an ionisation chamber and spectral dose distribution determination using semiconductor detectors have been performed. In addition, an unconventional system based on thermally stimulated exoelectron emission (TSEE) detectors, allowing to measure dose in a small volume and in the real cell environment has been tested and has proven itself appropriate in a variable dose range and in a liquid environment, in cases where reproducible laboratory conditions are provided. The biological endpoints clonogenic cell survival and micronucleus induction have been optimised for two established cell lines. The human mammary epithelial cells MCF-12A have been chosen due to the importance of RBE of soft X-rays for determination of risk from mammography. On the other hand, the use of the widespread mouse fibroblast cell line NIH/3T3 allows to compare the results with previously published data. The influence of the specific irradiation procedure at ELBE on the control level of cell survival and micronucleus induction has been tested and an irradiation system was developed and constructed. In addition, the RBE for soft X-rays was determined by X-ray tube irradiation at the Medical Department of Technische Universität Dresden. The RBE of 10 kV and 25 kV X-rays relative to 200 kV X-rays was determined. The RBE was found to be in the range from 1.0 to 1.4, depending on the used radiation quality, cell line and the biological endpoint, in agreement with previously published data for the same radiation qualities. These results confirm that systematical studies of RBE dependence on photon energy at the ELBE CR source are necessary and feasible.

Page generated in 0.1422 seconds