• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Aplicabilidade de medidas antropomÃtricas de distribuiÃÃo de adiposidade no segmento corporal superior (circunferÃncias cervical e escapular) como mÃtodos de avaliaÃÃo de risco cardiometabÃlico

Ana Paula Abreu Martins Sales 05 June 2009 (has links)
CoordenaÃÃo de AperfeiÃoamento de Pessoal de NÃvel Superior / Grupo DASA / LabPasteur / Existem vÃrios mÃtodos clÃnicos de avaliaÃÃo da obesidade, sendo mais utilizados na prÃtica o IMC e a medida da circunferÃncia abdominal (CA), esta Ãltima refletindo obesidade central. Estudos recentes tÃm sugerido que uma distribuiÃÃo de gordura no segmento corporal superior tambÃm pode ter relaÃÃo com aumento do risco cardiovascular (RCV). Este estudo teve por objetivo avaliar as circunferÃncias cervical (CC) e escapular (CE) como marcadores clÃnicos de obesidade superior e relacionÃ-las com outros dados antropomÃtricos e fatores de RCV. Foram avaliados 88 indivÃduos, de outubro de 2008 a janeiro de 2009, no CSAM-SMS/UFC; 24/88 (27,3%) eram do sexo masculino e 64/88 (72,7%) eram do sexo feminino. As principais mÃdias encontradas foram: idade (anos) - 39,1  10,9 (homens - 36,5  10,1 e mulheres - 40,0  11,1; p = 0,2); IMC (kg/mÂ) - 28,9  4,7 (homens - 28,7  4,6 e mulheres - 29,0  4,8); CC (cm) â 35  3,4 (homens â 39  2,6 e mulheres 33,5  2,0); CE (cm) - 94,1  8,4 (homens - 99,8  8,2 e mulheres - 92,0  7,4); CA (cm) - 94,2  11,3 (homens - 98,7  11,0 e mulheres - 92,6  11,0). Neste grupo, 38/88 (43,2%) indivÃduos preenchiam os critÃrios de SM da IDF. Encontrou-se correlaÃÃo (p<0,05) entre a CC e os seguintes parÃmetros: CA, circunferÃncia braquial (CB), CE, IMC, relaÃÃo cintura quadril (RCQ), relaÃÃo cervical coxa, pressÃo arterial sistÃlica (PAS), pressÃo arterial diastÃlica (PAD), Ãcido Ãrico, TGO, TGP, ferritina, HDL - colesterol, triglicÃrides e glicemia jejum; com a CE foram encontradas as seguintes correlaÃÃes: CA, CB, IMC, RCQ, PAS, Ãcido Ãrico, &#61543;GT, TGO, TGP, ferritina, HDL - colesterol, triglicÃrides, glicemia jejum e HOMA-IR. O uso das CC e CE como parÃmetros clÃnicos de obesidade superior neste grupo de indivÃduos mostrou correlaÃÃo com outros parÃmetros antropomÃtricos de obesidade, com componentes da SM e com exames laboratoriais marcadores de patologias associadas à SM, como hiperuricemia e doenÃa gordurosa nÃo-alcoÃlica. Estes dados sugerem que o uso destas circunferÃncias e, particularmente da CC, poderà ter um papel importante na avaliaÃÃo da obesidade e da SM, considerando a sua simplicidade e facilidade de execuÃÃo. Existe a necessidade de mais estudos para a confirmaÃÃo destes dados e para definiÃÃo de possÃveis pontos de corte da CC e CE em ambos os sexos, que possam predizer sobrepeso, obesidade e SM. / There are several clinical methods to evaluate obesity, it being used mainly the body mass index (BMI) and the waist circumference (WC), this one reflecting central obesity. Recent studies have suggested that an upper body obesity distribution also have relationship with high cardiovascular risk (CVR). This study aimed to evaluate neck circumference (NC) and scapular circumference (SC) as upper body obesity indexes, and their relationships with others anthropometrics parameters and CVR factors. Eighty-eight adults voluntaries were evaluated, since 2008 October to 2009 January, at the CSAM-SMS/UFC; 24/88 (27,3%) were males and 64/88 (72,7%) were females. The main means were: age - 39,1  10,9 years old (men - 36,5  10,1 and women - 40,0  11,1; p=0,2); BMI (kg/mÂ) - 28,9  4,7 (men - 28,7  4,6 and women - 29,0  4,8); NC (cm)- 35  3,4 (men â 39  2,6 and women - 33,5  2,0); SC (cm)- 94,1  8,4 (men - 99,8  8,2 and women - 92,0  7,4); WC (cm) - 94,2  11,3 (men - 98,7  11,0 and women â 92,6  11,0). In this group, 38/88 (43,2%) voluntaries had metabolic syndrome (MS) (IDF criteria). There was a significant correlation (p<0,05) between NC and: WC, braquial circumference (BC), SC, BMI, waist-to-hip ratio (WHR), SBP, DBP, uric acid, AST, ALP, ferritin, HDL-Chol, triglycerides and fasting glucose; and with SC: WC, BC, BMI, WHR, SBP, uric acid, &#61543;GT, AST, ALP, ferritin, HDL-Chol, triglycerides, fasting glucose and HOMA. NC and SC as upper body obesity indexes in this group showed correlations with other obesity anthropometrics parameters, with MS components and with laboratories parameters of MS associated diseases, hyperuricemia and nonalcoholic steatohepatitis. These data suggest the utility these circumferences and, particularly NC, would be an important tool to evaluated obesity and MS, due your simplicity and easy execution. However, subsequent studies are necessary to confirm these data and to define NC and SC cut points in both sexes to predict overweight, obesity and MS.
2

A aprendizagem da circunferÃncia na perspectiva da geometria analÃtica mediada pelo software educacional GeoGebra / The learning circumference from the perspective of analytical geometry mediated educational software GeoGebra

Josà Victor de Mesquita Filho 28 June 2014 (has links)
CoordenaÃÃo de AperfeÃoamento de Pessoal de NÃvel Superior / Neste trabalho, pretendeu-se analisar a eficÃcia do uso do Software Educacional GeoGebra como ferramenta pedagÃgica para o estudo da circunferÃncia na perspectiva da Geometria AnalÃtica. A metodologia de pesquisa teve enfoque quantitativo e qualitativo e o estudo foi realizado em uma escola pÃblica da rede estadual de Fortaleza, com uma turma de seis alunos do 3Â ano do Ensino MÃdio. Para tanto, aplicou-se a este grupo um prÃ-teste, para diagnosticar os conhecimentos prÃvios, em seguida houve uma intervenÃÃo pedagÃgica com um mÃdulo de atividades, mediado pelo GeoGebra, o que permitiu analisar se essa mediaÃÃo favoreceu o entendimento do aluno a respeito de circunferÃncia. Posteriormente, o grupo foi testado com um pÃs-teste. ApÃs esses passos, via um levantamento final de resultados chegou-se Ãs consideraÃÃes, confirmando os objetivos da pesquisa. No corpo do trabalho foi feito um levantamento sobre os PCN e o ensino da MatemÃtica, uma descriÃÃo das potencialidades de aplicaÃÃo do GeoGebra para o ensino da matemÃtica, uma descriÃÃo das potencialidades de aplicaÃÃo do GeoGebra para o ensino da circunferÃncia e para a facilitaÃÃo do relacionamento professor x aluno. A fundamentaÃÃo teÃrica baseou-se em autores como Even (2004); Borba & Penteado (2007); AraÃjo e NÃbriga (2010); DâAmbrÃsio e Barros (1990) e publicaÃÃes oficiais. / In this work, it was intended to analyze the effectiveness of using GeoGebra Educational Software as a pedagogical tool for the study of the circumference in the context of analytic geometry. The research methodology was quantitative and qualitative approach and the study was performed in a public school State network of Fortaleza with a class of six students in the 3rd year of high school. To this end, applied to this group a pre-test to diagnose the previous knowledge then, there was a pedagogical intervention with an activities module, mediated by GeoGebra, allowing to analyze if this mediation favored the studentâs understanding about in circumference. Later, the Group was tested with a post-test. After these steps, a final survey results led us considerations, confirming the objectives of research. In the body of the work was done a survey on the PCN and the teaching of mathematics, a description of the potential applications of GeoGebra to teach the circumference and the facilitation of teacher relationship x student. The theoretical foundation was based on authors such as Even (2004); Borba & Penteado (2007); AraÃjo e NÃbriga (2010); DâAmbrÃsio e Barros (1990) and official publications.
3

DiagnÃstico da restriÃÃo de crescimento fetal pela relaÃÃo diÃmetro transverso do cerebelo/circunferÃncia abdominal / Diagnosis of the restriction of growth fetal for the relation diameter transverso of the abdominal cerebelo/circunferÃncia

Josà de Arimatea Barreto 21 May 2003 (has links)
Conselho Nacional de Desenvolvimento CientÃfico e TecnolÃgico / CoordenaÃÃo de AperfeiÃoamento de Pessoal de NÃvel Superior / Objetivos: testar a validade da relaÃÃo diÃmetro transverso do cerebelo (DTC) /circunferÃncia abdominal (CA) como mÃtodo diagnÃstico ultra-sonogrÃfico da restriÃÃo de crescimento fetal (RCF). Determinar, atravÃs de curva ROC (receiver operator characteristic), o melhor ponto de corte da relaÃÃo DTC/CA. Verificar se a relaÃÃo DTC/CA tem sua acurÃcia modificada na dependÃncia do tipo de RCF (simÃtrica ou assimÃtrica) ou do tempo entre a ultra-sonografia e o parto. Comparar DTC/CA, no ponto de corte obtido, com a relaÃÃo comprimento do fÃmur (CF) /circunferÃncia abdominal (CA). MÃtodo: estudo prospectivo, seccional, envolvendo 250 gestantes com gravidez Ãnica, idade gestacional precisa, feto vivo. Foram realizadas ultra-sonografias obstÃtricas atà a resoluÃÃo da gestaÃÃo, mas somente a Ãltima foi considerada para anÃlise. Os neonatos cujas relaÃÃes DTC/CA estiveram maiores do que o ponto de corte determinado pela curva ROC foram considerados acometidos por RCF. Idem para a relaÃÃo CF/CA. Considerou-se como padrÃo-ouro para o diagnÃstico de RCF os recÃm-nascidos cujos pesos situaram-se abaixo do percentil 10 para a idade gestacional nas curvas de Lubchenco et al. (1963), corrigidas para sexo. Definiu-se RCF simÃtrica neonatos com Ãndice ponderal de Rohrer situado entre 2,2 e 3.0. Aqueles com RCF cujos Ãndices fossem < 2,2 foram classificados como RCF assimÃtrica. Resultados: a prevalÃncia da RCF foi de 12,4%. O ponto de corte da relaÃÃo DTC/CA determinado pela curva ROC foi 16,15. A sensibilidade, especificidade, valores preditivos positivo e negativo, acurÃcia, razÃes de verossimilhanÃa positiva e negativa foram de 77,4%, 82,6%, 38,7%, 96,3%, 82%, 4,5 e 3,7, respectivamente. Na RCF simÃtrica a sensibilidade e especificidade foram de 80,8% e 81,7%, respectivamente. Na assimÃtrica a sensibilidade e especificidade foram 60% e 75%, respectivamente. Resultados menores do que na simÃtrica, porÃm, nÃo estatisticamente significantes (p > 0,05). No intervalo de zero a sete dias entre a Ãltima ultra-sonografia e o parto, a sensibilidade e especificidade foram de 81,5% e 82,1%, respectivamente. No intervalo de oito a 14 dias, a sensibilidade e especificidade foram de 50% e 84,3%, respectivamente, sem diferenÃa estatisticamente significante entre os dois intervalos (p > 0,05). O ponto de corte da relaÃÃo CF/CA foi de 22,65, com sensibilidade, especificidade, valores preditivos positivo e negativo, acurÃcia, razÃes de verossimilhanÃa positiva e negativa de 67,7%, 81,7%, 34,4%, 94,7%, 80%, 3,7 e 2,5, respectivamente. ConclusÃes: a relaÃÃo DTC/CA no ponto de corte 16,15 mostrou-se mÃtodo eficaz no diagnÃstico de RCF, tanto simÃtrica quanto assimÃtrica, nÃo sendo influenciada pelo tempo entre a Ãltima ultra-sonografia e o parto. Sendo mÃtodo independente da idade gestacional, à especialmente Ãtil nos casos em que este dado à ignorado. A relaÃÃo CF/CA mostrou-se menos eficaz do que a DTC/CA no diagnÃstico da RCF. / Objectives: to evaluate the validity of transverse cerebellar diameter (TCD)/abdominal circumference (AC) ratio as an ultrasonographic diagnosis method of fetal growth restriction (FGR). To calculate by receiver operator characteristic (ROC) curve the best cut-off value of TCD/AC ratio. To verify whether TCD/AC has its accuracy modified according to the dependence of type of FGR (symmetric and asymmetric) or according to the time between ultrasonography and deliverance. To compare TCD/AC ratio at its cut-off with the femur length (FL)/ abdominal circumference (AC) ratio. Method: a prospective cross-sectional study, carried out in 250 pregnant women with singleton pregnancies between 20 and 42 weeks of gestation, known accurate gestational age with ultrasound confirmation, living fetuses. Obstetrics sonographic examinations were accomplished until gestation resolution, but only the last one, within 14 days of the deliverance, was used for analysis. Neonates with TCD/AC ratio greater than the cut-off, established by ROC curve were diagnosed as FGR. The same was considered for FL/AC ratio. We classified as gold standard for FGR in new-born infants, who presented birth weight bellow 10th percentile of gestational age according to the growth curves of Lubchenco et al. (1963), corrected according to their sex. Neonates showing FGR and Rohrer ponderal index between 2,2 and 3,0 were labeled as symmetric FGR. Those showing FGR and ponderal index below 2,2 were labeled as asymmetric FGR. Results: prevalence of FGR among the study group was 12,4%. The best cut-off value calculated by ROC curve for TCD/AC ratio was 16,15. The sensitivity, specificity, accuracy, positive predictive values and negative predictive values, likelihood ratio for positive and negative tests were 77,4%, 82,6%, 38,7%, 96,3%, 82%, 4,5 and 3,7, respectively. In the symmetric FGR, sensitivity and specificity were 80,8% and 81,7%, respectively. In the asymmetric FGR, sensitivity and specificity were 60% and 75%, respectively. Results lower than in the symmetric FGR, but not statistically significant (p > 0,05). In the interval zero to seven days between sonographic examination and deliverance, sensitivity and specificity were 81,5% and 82,1%, respectively. In the interval of eight to 14 days, sensitivity and specificity were 50% and 84,3%, respectively, with no statistically significant difference (p > 0,05). The best cut-off value calculated by ROC curve for FL/AC ratio was 22,65, showing sensitivity, specificity, accuracy, positive predictive values and negative predictive values, likelihood ratio for positive and negative tests of 67,7%, 81,7%, 34,4%, 94,7%, 80%, 3,7 and 2,5, respectively. Conclusions: TCD/AC ratio at cut-off 16,15 proved to be an effective method in antenatal diagnosis of FGR, both symmetric as asymmetric, with no influence of interval between ultrasonography examination and deliverance. As a gestational age-independent method, it is useful enough in the occurrence of cases where these data are unknown. FL/AC ratio proved is not so effective as TCD/AC ratio in diagnosis of FGR.

Page generated in 0.0392 seconds