Ensaios mecânicos e estudo histológico da interface dos implantes vertebrais / Mechanical and histological studies of the vertebral screw interfaceVendrame, José Roberto Benites 26 September 2006 (has links)
A cirurgia da coluna vertebral tem se desenvolvido muito nos últimos anos em decorrência da evolução dos sistemas de fixação. O comportamento da interface do parafuso com o osso continua sendo um aspecto não muito dominado. Como o parafuso é a âncora de sustentação, o trabalho procura investigar as técnicas de introdução do parafuso pedicular. Para atingir esse objetivo desenvolvemos o trabalho por meio de estudo com ensaios mecânicos de arrancamento e estudo histológico. Dois tipos de parafusos pediculares foram utilizados: parafuso pedicular do sistema USIS (Ulrich) e parafuso pedicular do sistema USS (Synthes). Os ensaios de arrancamento foram realizados em corpos de prova de madeira e poliuretano. O estudo histológico foi realizado em vértebras lombares de cadáver humano. No estudo envolvendo o parafuso USIS, foram testados os seguintes parâmetros: orifícios feitos com sonda e orifícios feitos com broca, todos do mesmo diâmetro do diâmetro interno do parafuso. Também foi testado o efeito do macheamento em relação ao não macheamento, nos orifícios feitos com broca. No estudo com os parafusos USS foram testados o efeito do diâmetro do orifício piloto tanto no estudo histológico como no arrancamento. No arrancamento destes parafusos também foi testado o efeito do tipo de orifício feito com sonda e com broca. O trabalho foi dividido em etapas: Primeira etapa foi o estudo de arrancamento do parafuso USIS; segunda etapa, estudo histológico de vértebra instrumentada com parafuso USIS, esta parte do trabalho foi constituída por análise de microscopia de luz e microscopia eletrônica de varredura; terceira etapa foi o arrancamento do parafuso USS; e quarta etapa foi o estudo histológico de vértebra instrumentada com parafuso USS. Os resultados da primeira etapa demonstraram que sonda teve efeito melhor do que broca, porque o resultado dos ensaios de arrancamento nos orifícios feitos com sondas teve maior força de arrancamento do que nos orifícios feitos por brocas. Na segunda etapa, análise histológica, verificou-se que os orifícios feitos por sonda apresentaram-se menores e com menor índice de fragmentação ao redor dos orifícios. Esses feitos tiveram diferença estatística significante, tanto na primeira, quanto na segunda etapa. Com relação ao macheamento não foi constatada diferença entre o não macheamento, em nenhuma das duas etapas. Na terceira etapa foi observado que, quando o orifício piloto ultrapassa o diâmetro interno do parafuso, ocorre tendência de queda na força de arrancamento de modo significativo, enquanto que orifício menor que o orifício piloto não tende a causar muita diferença na força de arrancamento em relação ao orifício correspondente ao diâmetro interno do parafuso. Também foi observado que o orifício feito com sonda oferece melhor força de ancoragem do que orifício feito com broca. Na quarta etapa foi constatado que quanto menor a broca para abrir o orifício piloto, menor o diâmetro do orifício, e não houve diferença significativa quanto ao índice de fragmentação ao redor do orifício entre os diferentes tamanhos de broca. Como conclusão pode-se dizer que sonda é melhor para se fazer o orifício piloto, uma vez que alarga menos o orifício, lesa menos as trabéculas ao redor do orifício e proporciona maior força de ancoragem do que broca. Também se pode concluir que o instrumental de menor diâmetro para abertura do orifício piloto é melhor, e o ponto crítico seria o diâmetro interno do parafuso. Não se deve fazer orifício piloto com instrumento de diâmetro maior que o diâmetro interno do parafuso. Não se constatou vantagem em relação ao fato de realizar ou deixar de realizar o macheamento. / Spine surgery has developed a lot in the last years because of the evolution of the fixation system. The behavior of a screw in the bone is still unknown in many ways. Because the screw is the anchor of sustentation, this work tries to find the answers involving the pedicle screw fixation. To reach this objective we developed this work based on mechanical and histological studies. Two kinds of pedicle screws were used: pedicle screw of the USIS (Ulrich) and pedicle screw of the USS system (Synthes). The pullout tests were made in wood and polyurethane. The histological study was done in lumbar vertebra of humans. In the study about the USIS screw, the follow parameters were tested: hole done with probe and hole done with drill, all of the same inner diameter of the screw. The effect of tapping and not tapping the hole done with drill was tested. In the USS screw study, the effect of the diameter pilot hole in the pullout tests and its historical analysis was seen. In the pullout tests of these screws, both kind of holes done with probes and a drill were tested. The work was divided into stages; first stage was the study of the pullout of the USIS screw; second stage was two studies, a light-microscopic one and a sweeping-electronic-microscope one of the slides of the instrumented vertebra with USIS screws; third stage was the study of the USS screws pullout comparing the relationship between the diameter of the holes and the inner diameter of the screw together with the type of hole (drill and probe); fourth stage was light-microscopic histological study of the instrumented vertebras which had had USIS screws. Results of the first stage showed that probes were more efficient than drills because the mechanical tests of pullouts from probe-made-holes showed the need of the use of a stronger force. In the second stage, a light-microscopic analysis showed that probe-made-holes had a lesser minimum diameter and a lower index of fragmentation than drill-made holes. With relation to the tapping, there was no difference between the holes. Under electronic microscope sweeping, it was seen that probes betters compact the bone around the screw. In the third stage, it was seen that when 9 the pilot orifice was greater than the screws internal diameter a significantly lower force was needed for pullout, while when the pilot orifice was smaller it did not significantly increase the force needed. It was also seen that probe-made-holes had a better anchorage than the drill-made-holes. In the fourth stage, the histological analysis of the slides done with light-microscopy showed that the smaller the diameter of the drill the smaller minimum diameter; there was no significant difference between fragmentation indexes. Conclusion: Probes are better than drills to make a pilot hole because they cause less damage to the surrounding bone and give a stronger anchorage for the screw; the smaller the instrument used to make the pilot hole, better will be the strength of the screws anchorage; the critical point which the hole must not exceed is the internal diameter of the screw. Tapping, or not, makes no difference to the anchorage.
|
2 |
Estudo da Participação do Osso Cortical e Esponjoso na Fixação de Implante Pedicular na Coluna Lombar. / Mechanical and histological studies of the vertebral screw interfaceVendrame, José Roberto Benites 28 April 2000 (has links)
Foi realizado estudo experimental com a finalidade de avaliar a participação do osso cortical e osso esponjoso dos pedículos vertebrais, na fixação dos parafusos pediculares. Foram utilizados 10 segmentos de coluna lombar de adultos, retirados durante autópsia. O diâmetro dos pedículos das vértebras de L1 a L5 foram avaliados, considerando o diâmetro total e o diâmetyro do osso esponjoso, tendo sido realizadas essas medidas por meio de tomografia computadorizada e medida direta. Os segmentos da coluna vertebral foram divididos em dois grupos para o estudo, sendo que cada grupo era formado por 5 conjuntos de segmentos da coluna lombar. No primeiro grupo a perfuração era realizada segundo os pontos de orientação utilizados nos procedimentos cirúrgicos ( faceta articular e processo transverso). No segundo grupo foi realizado corte transversal na porção média do pedículo, de modo que a perfuração e introdução dos parafusos no seu interior foram efetuados sob visão diereta. Após a perfuração dos pedículos utilizando-se broca de 3 mm, os parafusos eram introduzidos no interior do pedículo vertebral em ordem crescente de seus diâmetros, até que fosse observada alteração estrutural do pedículo, que eram avaliados por meio de medidas sucessivas, utilizando-se paquímetro e observação direta. Foram utilizados parafusos com diâmetro que variou de 3 a 12,5 mm, com progressão de 0,5 mm. Quando o diâmetro do parafuso excedia a resistência estrutural do pedículo, duas lesões foram observadas, a deformação plástica e o rompimento. No grupo I houve um número maior de deformação plástica, mas pelos cálculos estatísticos não houve diferença significativa entre os grupos. Os diâmetro tomográficos obtidos pela medida tomográfica e medida direta apresentaram-se diferentes e sem correlação entre si. No grupo II, como os parafuos foram introduzidos de modo mais centralizado, houve maior número de parafusos com diâmetro maior que o diâmetro do osso esponjoso, mas também não apresentou diferença entre os grupos, segundo avaliações estatísticas. Análise dos valores do diâmetro pedicular, diâmetro do osso esponjoso e do parafuso de maior diâmetro introduzido sem lesar o pedículo permitiu observar que a camada de osso cortical do pedículo foi pouco ocupada pelo parafuso em ambos os grupos. O valor médio da porcentagem do diâmetro do pedículo ocupado pelo parafuso no grupo I foi de 70,7% e no grupo II 75,34%. Foi observado que os parafusos, de um modo geral, apresentaram ancoragem principalmente na porção de osso esponjoso do pedículo vertebral, tendo sido pequena a porcentagem de osso cortical do pedículo vertebral utilizado para a sua ancoragem. / Spine surgery has developed a lot in the last years because of the evolution of the fixation system. The behavior of a screw in the bone is still unknown in many ways. Because the screw is the anchor of sustentation, this work tries to find the answers involving the pedicle screw fixation. To reach this objective we developed this work based on mechanical and histological studies. Two kinds of pedicle screws were used: pedicle screw of the USIS (Ulrich) and pedicle screw of the USS system (Synthes). The pullout tests were made in wood and polyurethane. The histological study was done in lumbar vertebra of humans. In the study about the USIS screw, the follow parameters were tested: hole done with probe and hole done with drill, all of the same inner diameter of the screw. The effect of tapping and not tapping the hole done with drill was tested. In the USS screw study, the effect of the diameter pilot hole in the pullout tests and its historical analysis was seen. In the pullout tests of these screws, both kind of holes done with probes and a drill were tested. The work was divided into stages; first stage was the study of the pullout of the USIS screw; second stage was two studies, a light-microscopic one and a sweeping-electronic-microscope one of the slides of the instrumented vertebra with USIS screws; third stage was the study of the USS screws pullout comparing the relationship between the diameter of the holes and the inner diameter of the screw together with the type of hole (drill and probe); fourth stage was light-microscopic histological study of the instrumented vertebras which had had USIS screws. Results of the first stage showed that probes were more efficient than drills because the mechanical tests of pullouts from probe-made-holes showed the need of the use of a stronger force. In the second stage, a light-microscopic analysis showed that probe-made-holes had a lesser minimum diameter and a lower index of fragmentation than drill-made holes. With relation to the tapping, there was no difference between the holes. Under electronic microscope sweeping, it was seen that probes betters compact the bone around the screw. In the third stage, it was seen that when the pilot orifice was greater than the screws internal diameter a significantly lower force was needed for pullout, while when the pilot orifice was smaller it did not significantly increase the force needed. It was also seen that probe-made-holes had a better anchorage than the drill-made-holes. In the fourth stage, the histological analysis of the slides done with light-microscopy showed that the smaller the diameter of the drill the smaller minimum diameter; there was no significant difference between fragmentation indexes. Conclusion: Probes are better than drills to make a pilot hole because they cause less damage to the surrounding bone and give a stronger anchorage for the screw; the smaller the instrument used to make the pilot hole, better will be the strength of the screw\'s anchorage; the critical point which the hole must not exceed is the internal diameter of the screw. Tapping, or not, makes no difference to the anchorage.
|
3 |
Efeitos adversos da morfina, metadona e tramadol no pós-operatório de cães submetidos à cirurgia da coluna vertebral / Adverse effects of morphine, methadone and tramadol in the postoperative period of dogs undergoing vertebral surgeryRipplinger, Angel 03 February 2017 (has links)
Postoperative pain in dogs undergoing vertebral surgery is classified as severe and is important an adequate approach to it, because it can influences recovery time, quality of life and surgery outcome. Opioids are indicating for postoperative pain treatment in these surgeries. Opioids may have adverse effects that may require attention. There are few clinical studies that present the adverse effects of these analgesics in canine postoperative period. The aim of this retrospective study was to present the adverse effects of morphine, methadone and tramadol in canine vertebral surgery postoperative period. There were revised the postoperative records of 180 dogs and the changes resulted from the opioids use were noted. The adverse effects observed were anorexia, hypophagia, vomiting, vocalization, bradycardia, hypothermia, panting, sedation. Pain was also observed in some dogs. A significant difference was found in anorexia between dogs treated with morphine and tramadol and methadone and tramadol. Significant difference was also found in pain between dogs treated with morphine and tramadol. The association of metamizole and morphine or metamizole and methadone was not different in relation to the adverse effects. There was also no difference with the dosage variation and the adverse effects. In conclusion, morphine, methadone and tramadol have adverse effects when used for pain control in the postoperative period of dogs submitted to vertebral surgery. Anorexia, hypophagia and emesis were frequent adverse effects observed with morphine and methadone and, despite tramadol presented less adverse effects, its use may be not beneficial in the studied doses when we consider the degree of pain, however more controlled studies with clinical situation are needed to confirm this. / A dor pós-operatória em cães submetidos a cirurgias da coluna vertebral é considerada severa e o manejo inadequado pode influenciar no tempo de recuperação do paciente, na qualidade de vida e no resultado cirúrgico. Dentre os analgésicos indicados para uso no pós-operatório dessas cirurgias tem-se os opioides, os quais podem apresentar inúmeros efeitos adversos que requerem atenção. Devido à escassez de estudos clínicos acerca dos efeitos adversos desses fármacos no pós-operatório de cães, objetivou-se com o presente estudo retrospectivo apresentar os efeitos adversos da morfina, metadona e tramadol utilizados no pós-operatório de cirurgias da coluna vertebral. Foram revisadas e avaliadas as fichas de 180 cães e os principais efeitos adversos observados foram anorexia, hiporexia, vômito, salivação, vocalização, bradicardia, hipotermia, ofegação e sedação. Também foi verificada persistência de dor mesmo com uso dos analgésicos. Houve diferença na ocorrência de anorexia nos cães tratados com morfina ou metadona em relação aos tratados com tramadol. Outra observação que apresentou diferença foi referente à dor pós-operatória entre os grupos morfina e tramadol (p<0,05). A associação de dipirona com morfina e com metadona não revelou diferença com relação à ocorrência de efeitos adversos, bem como a variação de doses. Conclui-se que a morfina, a metadona e o tramadol apresentam efeitos adversos quando empregados para tratamento da dor pós-operatória em cães submetidos à cirurgia da coluna vertebral. A anorexia, a hipofagia e o vômito foram os efeitos adversos frequentes com o uso de morfina e de metadona e, mesmo que o tramadol apresente menor ocorrência de efeitos adversos, seu uso pode não ser vantajoso na dose estudada quando se leva em consideração o grau de dor, entretanto mais estudos controlados com situações clínicas são necessários para confirmação desse achado.
|
4 |
Ensaios mecânicos e estudo histológico da interface dos implantes vertebrais / Mechanical and histological studies of the vertebral screw interfaceJosé Roberto Benites Vendrame 26 September 2006 (has links)
A cirurgia da coluna vertebral tem se desenvolvido muito nos últimos anos em decorrência da evolução dos sistemas de fixação. O comportamento da interface do parafuso com o osso continua sendo um aspecto não muito dominado. Como o parafuso é a âncora de sustentação, o trabalho procura investigar as técnicas de introdução do parafuso pedicular. Para atingir esse objetivo desenvolvemos o trabalho por meio de estudo com ensaios mecânicos de arrancamento e estudo histológico. Dois tipos de parafusos pediculares foram utilizados: parafuso pedicular do sistema USIS (Ulrich) e parafuso pedicular do sistema USS (Synthes). Os ensaios de arrancamento foram realizados em corpos de prova de madeira e poliuretano. O estudo histológico foi realizado em vértebras lombares de cadáver humano. No estudo envolvendo o parafuso USIS, foram testados os seguintes parâmetros: orifícios feitos com sonda e orifícios feitos com broca, todos do mesmo diâmetro do diâmetro interno do parafuso. Também foi testado o efeito do macheamento em relação ao não macheamento, nos orifícios feitos com broca. No estudo com os parafusos USS foram testados o efeito do diâmetro do orifício piloto tanto no estudo histológico como no arrancamento. No arrancamento destes parafusos também foi testado o efeito do tipo de orifício feito com sonda e com broca. O trabalho foi dividido em etapas: Primeira etapa foi o estudo de arrancamento do parafuso USIS; segunda etapa, estudo histológico de vértebra instrumentada com parafuso USIS, esta parte do trabalho foi constituída por análise de microscopia de luz e microscopia eletrônica de varredura; terceira etapa foi o arrancamento do parafuso USS; e quarta etapa foi o estudo histológico de vértebra instrumentada com parafuso USS. Os resultados da primeira etapa demonstraram que sonda teve efeito melhor do que broca, porque o resultado dos ensaios de arrancamento nos orifícios feitos com sondas teve maior força de arrancamento do que nos orifícios feitos por brocas. Na segunda etapa, análise histológica, verificou-se que os orifícios feitos por sonda apresentaram-se menores e com menor índice de fragmentação ao redor dos orifícios. Esses feitos tiveram diferença estatística significante, tanto na primeira, quanto na segunda etapa. Com relação ao macheamento não foi constatada diferença entre o não macheamento, em nenhuma das duas etapas. Na terceira etapa foi observado que, quando o orifício piloto ultrapassa o diâmetro interno do parafuso, ocorre tendência de queda na força de arrancamento de modo significativo, enquanto que orifício menor que o orifício piloto não tende a causar muita diferença na força de arrancamento em relação ao orifício correspondente ao diâmetro interno do parafuso. Também foi observado que o orifício feito com sonda oferece melhor força de ancoragem do que orifício feito com broca. Na quarta etapa foi constatado que quanto menor a broca para abrir o orifício piloto, menor o diâmetro do orifício, e não houve diferença significativa quanto ao índice de fragmentação ao redor do orifício entre os diferentes tamanhos de broca. Como conclusão pode-se dizer que sonda é melhor para se fazer o orifício piloto, uma vez que alarga menos o orifício, lesa menos as trabéculas ao redor do orifício e proporciona maior força de ancoragem do que broca. Também se pode concluir que o instrumental de menor diâmetro para abertura do orifício piloto é melhor, e o ponto crítico seria o diâmetro interno do parafuso. Não se deve fazer orifício piloto com instrumento de diâmetro maior que o diâmetro interno do parafuso. Não se constatou vantagem em relação ao fato de realizar ou deixar de realizar o macheamento. / Spine surgery has developed a lot in the last years because of the evolution of the fixation system. The behavior of a screw in the bone is still unknown in many ways. Because the screw is the anchor of sustentation, this work tries to find the answers involving the pedicle screw fixation. To reach this objective we developed this work based on mechanical and histological studies. Two kinds of pedicle screws were used: pedicle screw of the USIS (Ulrich) and pedicle screw of the USS system (Synthes). The pullout tests were made in wood and polyurethane. The histological study was done in lumbar vertebra of humans. In the study about the USIS screw, the follow parameters were tested: hole done with probe and hole done with drill, all of the same inner diameter of the screw. The effect of tapping and not tapping the hole done with drill was tested. In the USS screw study, the effect of the diameter pilot hole in the pullout tests and its historical analysis was seen. In the pullout tests of these screws, both kind of holes done with probes and a drill were tested. The work was divided into stages; first stage was the study of the pullout of the USIS screw; second stage was two studies, a light-microscopic one and a sweeping-electronic-microscope one of the slides of the instrumented vertebra with USIS screws; third stage was the study of the USS screws pullout comparing the relationship between the diameter of the holes and the inner diameter of the screw together with the type of hole (drill and probe); fourth stage was light-microscopic histological study of the instrumented vertebras which had had USIS screws. Results of the first stage showed that probes were more efficient than drills because the mechanical tests of pullouts from probe-made-holes showed the need of the use of a stronger force. In the second stage, a light-microscopic analysis showed that probe-made-holes had a lesser minimum diameter and a lower index of fragmentation than drill-made holes. With relation to the tapping, there was no difference between the holes. Under electronic microscope sweeping, it was seen that probes betters compact the bone around the screw. In the third stage, it was seen that when 9 the pilot orifice was greater than the screws internal diameter a significantly lower force was needed for pullout, while when the pilot orifice was smaller it did not significantly increase the force needed. It was also seen that probe-made-holes had a better anchorage than the drill-made-holes. In the fourth stage, the histological analysis of the slides done with light-microscopy showed that the smaller the diameter of the drill the smaller minimum diameter; there was no significant difference between fragmentation indexes. Conclusion: Probes are better than drills to make a pilot hole because they cause less damage to the surrounding bone and give a stronger anchorage for the screw; the smaller the instrument used to make the pilot hole, better will be the strength of the screws anchorage; the critical point which the hole must not exceed is the internal diameter of the screw. Tapping, or not, makes no difference to the anchorage.
|