• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 17
  • 3
  • Tagged with
  • 18
  • 8
  • 7
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Étude de l'incidence des coïncidences triples simulées et mesurées à partir de systèmes TEP pixélisés sur les critères de qualité d'image / Study on the incidence of simulated and measured triple coincidences from pixelated PET system on image quality criteria

Clerk-Lamalice, Julien January 2015 (has links)
Résumé : En tomographie d'émission par positrons (TEP), les données sont enregistrées par la détection de paires de photons de haute énergie (511~keV) en coïncidence. Or, dans un système de détection pixélisé, comme celui des scanners LabPET, la diffusion Compton dans les cristaux voisins entraîne la détection fréquente d'événements multiples, présentement rejetés dans le processus de reconstruction des images. Ces événements multiples peuvent augmenter l'efficacité de détection du scanner de façon significative, mais il reste à démontrer que l'inclusion de ces coïncidences peut améliorer la sensibilité sans affecter les critères de qualité des images, tels que la résolution spatiale et le contraste. Le but du projet est de démontrer l'influence de l'inclusion de ces événements dans le processus de reconstruction d'images. Les méthodes à critères fixes seront utilisées pour sélectionner les coïncidences triple obtenues à partir de données simulées à l’aide du logiciel de simulation GATE (« Geant4 Application for Tomographic Emission ») et de mesures réelles effectuées sur les scanners LabPET. // Abstract : In positron emission tomography, data are acquired by detecting pairs of high energy photons (511 keV) in coincidence. Thus, in a highly pixelated system such as the LabPET scanner, Compton diffusion in neighboring crystals can trigger the detection of multiple events (multiple coincidences) which are currently rejected from the reconstruction process. These multiple events can increase significantly the scanner’s detection efficiency, but it remains to be demonstrated that they can be used to increase sensitivity in the images without decreasing image quality criteria, such as the spatial resolution and contrast. The goal of this work is to demonstrate the influence of including these events in the image reconstruction process. Fixed criteria methods were used to select triple coincidences obtained from simulated data from the GATE (Geant4 Application for Tomography Emission) software and real measurements from the LabPET scanner.
2

Dynamique de photofragmentation de molécules d'intérêt biologique protonées / Photofragmentation dynamics of small protonated biomolecules

Pérot-Taillandier, Marie 10 January 2011 (has links)
L’expérience Arc-En-Ciel permet d’étudier la dynamique de photofragmentation UV de biomolécules produites par une source « électrospray ». La spécificité du dispositif expérimental utilisé repose sur la détection en coïncidence des photo-fragments ioniques et neutres issus d’un même évènement physique de fragmentation. L’étude de molécules simplement chargées permet d’identifier chaque canal de fragmentation par la masse du fragment ionique émis. En corrélant les informations temporelles et spatiales des photo-fragments détectés, on définit :- le nombre et la masse des fragments neutres associés à chaque fragment ionique- le nombre d’étapes de fragmentation de chaque canal et leurs temps caractéristiques(20 ns ≤ τ < 1 μs).L’ensemble de ces informations permet une description complète de la dynamique de photofragmentation du système étudié.La dynamique de photofragmentation du tryptophane protoné est régie par des transferts concertés d’électron et de proton à l’état excité. Lorsque le tryptophane protoné est complexé à un éther-couronne, les transferts de protons sont inhibés. Nous observons alors une modification de la dynamique de fragmentation.Pour de petits peptides protonés contenant le tryptophane, la dynamique à l’état excité est gouvernée par la position du tryptophane dans la chaîne peptidique. Les voies de fragmentation spécifiques UV, mises en évidence pour ces peptides, sont expliquées par les mêmes mécanismes de transfert concerté d’électron et de proton. Nous montrons cependant que ces mécanismes diffèrent suivant la composition du peptide. / The Arc-En-Ciel experiment allows the investigation of UV photo-fragmentation dynamics of protonated biomolecules produced by an electrospray ion source. The specificity of the set-up is based on the detection in coincidence of ionic and neutral photo-fragments coming from the same fragmentation event. The study of simple charged molecules allows the identification of each fragmentation channel by the mass of the emitted ionic fragment. With the time and spatial correlation of the information of detected photo-fragments we identify:- the number of neutral fragments as well as their masses associated with each ionic fragment- the number of fragmentation steps of each channel as well as their fragmentation times (20 ns ≤ τ < 1 μs)This information provides a comprehensive understanding of the photo-fragmentation dynamics.The photo-fragmentation dynamics of protonated Tryptophan is driven by concerted electron and proton transfers in the excited state. When protonated Tryptophan is complexed witha crown-ether, proton transfers are inhibited and dynamics is modified.The excited state dynamics of small protonated peptides containing Tryptophan is governed by the position of Tryptophan in the peptide chain. The specific fragmentation channels involved are explained by concerted electron and proton transfers. We show how these mechanisms change with the composition of peptides.
3

Récupération en temps réel de coïncidences diffuses triples dans un scanner TEP à l'aide d'un réseau de neurones artificiels

Geoffroy, Charles January 2013 (has links)
Le projet de recherche s’inscrit dans un contexte d'imagerie moléculaire, où la modalité d'imagerie d'intérêt est la tomographie d'émission par positrons (TEP) appliquée en recherche sur les petits animaux. Afin de permettre l’observation de détails infimes, les plus récents développements sur ce genre de scanner ont constamment amélioré leur résolution spatiale, sans toutefois obtenir les mêmes progrès en terme de sensibilité. Parmi les méthodes étudiées afin de combler cette lacune, la récupération de coïncidences triples à l’aide d'un réseau de neurones artificiels semble être une technique viable. En effet, malgré une dégradation du contraste, celle-ci permet d'améliorer substantiellement la sensibilité de l’image. Cette technique n'est cependant pas prête à être intégrée aux protocoles de recherche, car son application est pour l’instant limitée à un traitement hors ligne des données d'acquisition d'un scanner. En conséquence, la faisabilité d'une telle approche en temps réel n'est donc pas garantie, car le flux de coïncidences d'un scanner est très important et ses ressources de calculs sont limitées. Dans l’intention d'inclure ce gain en sensibilité pendant une acquisition où le traitement est effectué en temps réel, ce projet de recherche propose une implémentation d'un réseau de neurones artificiels au sein d'une matrice de porte programmable (FPGA) pouvant récupérer en temps réel les coïncidences diffuses triples du scanner LabPET, version 4 cm. La capacité de traitement obtenue est 1 087 000 coïncidences triples par seconde en utilisant 23.1% des ressources d'unités logiques d'un FPGA de modèle XC2VP50. Comparativement à un programme équivalent à haute précision sur ordinateur personnel, l’analyse de validité prend la même décision dans 99.9% des cas et la même ligne de réponse est choisie dans 97.9% des cas. Intégrées à l’image, les coïncidences triples permettent une augmentation de sensibilité jusqu’à 39.7%, valeur qui est en deçà [de] celle obtenue des recherches antérieures, mais expliquée par des conditions d'acquisition différente. Au niveau de la qualité de l’image, la dégradation du contraste de 16,1% obtenu est similaire à celle observée antérieurement. En référence à ces résultats, les ressources limitées d'un scanner de tomographie d'émission par positrons sont avérées suffisantes pour permettre l’implémentation d'un réseau de neurones artificiels devant classifier en temps réel les coïncidences triples du scanner. En terme de contributions, l’implémentation en temps réel réalisée pour ce projet confirme la faisabilité de la technique et apporte une nouvelle approche concrète pour améliorer la sensibilité. Dans une autre mesure, la réussite du projet de recherche contribue à faire connaître la technique des réseaux de neurones artificiels dans le domaine de la tomographie d’émission par positrons. En effet, cette approche est pertinente à considérer en guise d'alternative aux solutions traditionnelles. Par exemple, les réseaux de neurones artificiels pourraient effectuer une évaluation correcte du phénomène des coïncidences fortuites.
4

Développement de la sensibilité dans l'imagerie médicale TEP à détecteurs multiples

Rechka, Sanae January 2010 (has links)
Cette thèse s'inscrit dans la perspective d'augmentation de la sensibilité de scanners de tomographie d'émission par positrons (TEP) en baissant le seuil d'énergie pour intégrer les événements de faible énergie dans l'image TEP.Cette baisse du seuil nécessite une évaluation correcte des interactions multiples particulièrement dues à la diffusion Compton inter-cristal, afin d'assurer un comptage précis des coïncidences fortuites et vraies, et conséquemment une quantification exacte de la distribution de l'activité dans l'objet. Afin d'atteindre cet objectif, et vu la complexité des phénomènes de la diffusion Compton et des coïncidences fortuites, les développements ainsi que la validation de ce travail de recherche ont été assistés par le simulateur évolué GATE"Geant4 application for tomographic emission". D'abord un modèle de simulation GATE pour le scanner LabPET a été développé et validé théoriquement et expérimentalement. Ce modèle a ensuite servi à l'étude du mécanisme de la diffusion Compton inter-cristal et des coïncidences fortuites, notamment en lien avec la fixation du seuil d'énergie. Finalement, une technique d'estimation des fortuits tenant compte des interactions multiples a été développée et validée dans différentes conditions d'imagerie et pour différents seuils d'énergie, en utilisant principalement le modèle GATE du LabPET et aussi d'autres géométries de scanners. À l'opposé des méthodes revues dans la littérature, cette technique assure une faible erreur d'estimation des coïncidences fortuites (< 2%) même à très bas seuils d'énergie en présence de la diffusion Compton inter-cristal ou à très hautes activités, et permet d'atteindre une haute sensibilité de scanner.Cette thèse a fait l'objet de différentes communications scientifiques dans des conférences et journaux internationaux.
5

Développement et modélisation d'un spectromètre multidétecteur Ge/Si pour la détection des ultra-traces de produits de fission dans l'environnement / Development and simulation of a Ge/Si multi-detector spectrometer for fission products traces detection in the environment

Cagniant, Antoine 03 April 2015 (has links)
Dans le cadre de la vérification du Traité d'Interdiction Complète des Essais nucléaires (TICE), la mesure des traces de produits de fission dans l'environnement est fondamentale. Ces mesures sont des indicateurs indéniables du caractère nucléaire d'une explosion. Afin d'améliorer ses capacités de mesures, le CEA/DAM-Ile de France s'est équipé d'un nouveau spectromètre de surface. Ce spectromètre, baptisé GAMMA3, est équipé de trois détecteurs au germanium, de deux détecteurs au silicium (intégrés à une cellule de mesure des gaz, la PIPSBox) et d'un blindage optimisé. Ce blindage permet de diminuer très fortement les interférences dues au flux de muons, neutrons ou photons environnementaux. Le bruit de fond radiologique au sein de l'enceinte de mesure est parmi les plus bas rencontrés dans le domaine. Cet ensemble de détecteurs à hautes résolutions énergétiques permet d'optimiser la mesure d'un échantillon suivant son activité, sa géométrie ou sa nature. En particulier, un gaz noble sera mesuré en coïncidence photon/électron, un échantillon actif sera mesuré en coïncidence photon/photon, et un échantillon faiblement actif sera mesuré avec un fort rendement de détection. En combinant ces deux points, les Activités Minimales Détectables requises pour un laboratoire expert du TICE sont atteintes très rapidement. En particulier, elles sont obtenues en 5h pour le 140-Ba (24 mBq), en 6h30 pour les 131m/133m-Xe (5 mBq) et en 7h15 pour le 133-Xe (5mBq) contre les 6 jours réglementaires. / For the verification of the Comprehensive nuclear Test Ban Treaty (CTBT), the measurement of fission products trace levels in the environment is fundamental. Such measurement is a key indicator of a nuclear explosion. For constant amelioration of these measurements, the CEA/DAM-Ile de France has developed and installed a new dedicated surface spectrometer. Named GAMMA3, it is equipped with three germanium detectors, two silicon detectors (integrated in a dedicated gas cell, the PIPSBox) and includes an optimized shielding.This shielding reduces greatly the interference of environmental photons, muons and neutrons with the detectors. The residual radiological background measured inside the shielding is the community’s lowest for a surface laboratory. This set of high energy resolution detectors allows the operator to optimize a measurement according to the sample geometry, activity or nature. More precisely, a radioactive noble gas can be measured by photon/electron coincidence, an active sample can be measured by photon/photon coincidence, and a low-active sample can be measured in a high-efficiency configuration. Combining optimized shielding and optimized measurement, Minimum Detectable Activities required for CTBT certification are obtained quickly. Specifically, MDA is reached in 5 hours for 140-Ba (24 mBq), in 6h30 hours for 131m/133m-Xe (5 mBq) and in 7h15 for 133-Xe (5 mBq), when CTBT requirement is in 6 days.
6

Efficacité de détection en tomographie d'émission par positrons: une approche par intelligence artificielle

Michaud, Jean-Baptiste January 2014 (has links)
En Tomographie d'Émission par Positrons (TEP), la course à la résolution spatiale nécessite des détecteurs de plus en plus petits, produisant plus de diffusion Compton avec un impact négatif sur l’efficacité de détection du scanner. Plusieurs phénomènes physiques liés à cette diffusion Compton entachent tout traitement des coïncidences multiples d'une erreur difficile à borner et à compenser, tandis que le nombre élevé de combinaisons de détecteurs complexifie exponentiellement le problème. Cette thèse évalue si les réseaux de neurones constituent une alternative aux solutions existantes, problématiques parce que statistiquement incertaines ou complexes à mettre en œuvre. La thèse réalise une preuve de concept pour traiter les coïncidences triples et les inclure dans le processus de reconstruction, augmentant l'efficacité avec un minimum d'impact sur la qualité des images. L'atteinte des objectifs est validée via différents critères de performance comme le gain d'efficacité, la qualité de l'image et le taux de succès du calcul de la ligne de réponse (LOR), mesurés en priorité sur des données réelles. Des études paramétriques montrent le comportement général de la solution : un réseau entraîné avec une source générique démontre pour le taux d'identification de la LOR une bonne indépendance à la résolution en énergie ainsi qu'à la géométrie des détecteurs, du scanner et de la source, pourvu que l'on ait prétraité au maximum les données pour simplifier la tâche du réseau. Cette indépendance, qui n'existe en général pas dans les solutions existantes, laisse présager d'un meilleur potentiel de généralisation à d'autres scanners. Pour les données réelles du scanner LabPET[indice supérieur TM], la méthode atteint un gain d'efficacité aux alentours de 50%, présente une dégradation de résolution acceptable et réussit à recouvrer le contraste de manière similaire aux images de référence, en plus de fonctionner en temps réel. Enfin, plusieurs améliorations sont anticipées.
7

Dynamique de fragmentation induite par collision de petits agrégats métalliques

PICARD, Yan 08 April 1999 (has links) (PDF)
L'objet de ce travail est l'analyse complète de la fragmentation d'agrégats d'alcalins (Na_n^+ (n < 10), NaK^+ et K_2^+) consécutive à une collision avec une cible légère atomique (He) ou moléculaire (H_2). Il s'agit d'étudier les mécanismes d'excitation et de désexcitation, c'est-à-dire de déterminer comment l'énergie est transmise à l'agrégat au cours de la collision et de quelle manière cette énergie se répartie sur les différents degrés de liberté du système pour conduire à sa fragmentation. Deux types d'interaction gouvernent les processus de dissociation induite par collision : les mécanismes électroniques pour lesquels la molécule est portée dans un état dissociatif par perturbation de son nuage électronique et les mécanismes impulsionnels où la quantité de mouvement transférée aux atomes provoque la dissociation rovibrationnelle de la molécule. La méthode expérimentale utilisée repose sur la mesure des vecteurs vitesse des fragments issus de la collision et détectés en coïncidence. Elle permet de remonter à la cinématique complète de la fragmentation et ainsi de séparer et caractériser pour la première fois sans ambiguïté les deux types d'interaction. Les deux mécanismes de base de dissociation induite par collision ont pu être clairement mis en évidence dans le cas du dimère Na_2^+. L'étude de la molécule hétéronucléaire NaK^+ a révélé la combinaison des mécanismes électronique et impulsionnel pour certaines voies de dissociation. Cette méthode expérimentale appliquée à l'étude de la fragmentation des agrégats métalliques Na_n^+ (n < 10) a montré le rôle et l'importance relative de ces mécanismes ainsi que leur évolution avec la taille du système. L'analyse complète de la multi-fragmentation du système simple Na_3^+ est également présentée.
8

Nouvelle méthode spatio-spectrale de correction de la diffusion en tomographie à émission de positons

Bastien, Guérin 05 May 2010 (has links) (PDF)
Nous avons développé une simulation de Monte Carlo rapide pour la tomographie à émission de positons (TEP) fondée sur le code SimSET modélisant la propagation des photons gammas dans le patient et le scanner basé sur un design en blocs. La validation de ce simulateur avec un code bien validé, GATE, et des données acquises sur un scanner TEP GE Discovery STE a montré qu'il modélise précisément les spectres en énergie (erreur inférieure à 4,6%), la résolution spatiale (6,1%), la fraction de diffusé (3,5%), la sensibilité aux coïncidences primaires (2,3%) et les taux de comptage (12,7%). Nous avons ensuite développé une correction de la diffusion incorporant l'énergie des photons détectés en mode liste en plus de la distribution spatiale des coïncidences diffusées. Notre approche est basée sur une reformulation de la fonction de vraisemblance contenant l'information en énergie donnant lieu à un algorithme de reconstruction EM contenant des termes de correction de la diffusion spatiaux et énergétiques. Nous avons aussi proposé une nouvelle méthode de normalisation du sinogramme diffusé utilisant l'information en énergie. Enfin, nous avons développé une méthode d'estimation des spectres primaires et diffusés détectés dans différents secteurs du scanner TEP. Nous avons évalué notre méthode spatio-spectrale de correction de la diffusion ainsi que la méthode spatiale traditionnelle dans des simulations de Monte Carlo réalistes. Ces résultats montrent que notre approche réduit les biais de quantification de 60% dans les régions froides dans les patients obèses, donnant lieu à des erreurs de quantification inférieures à 13% même dans les patients les plus larges en mode 3D (comparé à une erreur de 65% avec la méthode conventionnelle).
9

Efficacité de détection en tomographie d'émission par positrons: une approche par intelligence artificielle

Michaud, Jean-Baptiste January 2014 (has links)
En Tomographie d'Émission par Positrons (TEP), la course à la résolution spatiale nécessite des détecteurs de plus en plus petits, produisant plus de diffusion Compton avec un impact négatif sur l’efficacité de détection du scanner. Plusieurs phénomènes physiques liés à cette diffusion Compton entachent tout traitement des coïncidences multiples d'une erreur difficile à borner et à compenser, tandis que le nombre élevé de combinaisons de détecteurs complexifie exponentiellement le problème. Cette thèse évalue si les réseaux de neurones constituent une alternative aux solutions existantes, problématiques parce que statistiquement incertaines ou complexes à mettre en œuvre. La thèse réalise une preuve de concept pour traiter les coïncidences triples et les inclure dans le processus de reconstruction, augmentant l'efficacité avec un minimum d'impact sur la qualité des images. L'atteinte des objectifs est validée via différents critères de performance comme le gain d'efficacité, la qualité de l'image et le taux de succès du calcul de la ligne de réponse (LOR), mesurés en priorité sur des données réelles. Des études paramétriques montrent le comportement général de la solution : un réseau entraîné avec une source générique démontre pour le taux d'identification de la LOR une bonne indépendance à la résolution en énergie ainsi qu'à la géométrie des détecteurs, du scanner et de la source, pourvu que l'on ait prétraité au maximum les données pour simplifier la tâche du réseau. Cette indépendance, qui n'existe en général pas dans les solutions existantes, laisse présager d'un meilleur potentiel de généralisation à d'autres scanners. Pour les données réelles du scanner LabPET[indice supérieur TM], la méthode atteint un gain d'efficacité aux alentours de 50%, présente une dégradation de résolution acceptable et réussit à recouvrer le contraste de manière similaire aux images de référence, en plus de fonctionner en temps réel. Enfin, plusieurs améliorations sont anticipées.
10

Développement d’un système de mesure ultra-compact à coïncidences électron/photon pour la détection et la caractérisation de radionucléides du xénon / Development of an ultra-compact detection system using electron/photon coincidence technique for the detection and the characterization of xenon radionuclides

Thomas, Vincent 15 November 2019 (has links)
Dans le cadre du Traité d'Interdiction Complète des Essais Nucléaires (TICE), le Système de Surveillance International (SSI) a été développé. Ce réseau consiste en plusieurs centaines de stations de mesures dont le rôle est de détecter la signature d'un essai nucléaire clandestin. Quatre types de mesures sont effectués: sismique, hydro-acoustique, infrason et radionucléide. Dans le cas particulier d'un essai nucléaire souterrain, seule la mesure des radionucléides est adéquate pour mettre en évidence le caractère nucléaire de l'explosion. Quatre radionucléides du xénon sont produits en masse lors d'un essai nucléaire: le 131m-Xe, le 133m-Xe, le 133-Xe, et le 135-Xe. Une faible proportion de ces gaz parvient à diffuser à travers les fissures de la cavité et se retrouver dans l'atmosphère. A cause de la dilution atmosphérique, les concentrations de ces quatre radionucléides sont extrêmement faibles et par conséquent difficiles à détecter. De plus, le bruit de fond atmosphérique ne cesse d'augmenter car ces gaz radioactifs sont également produits et relâchés par les usines de production de radio-isotopes médicaux et les centrales nucléaires. Afin de renforcer le réseau de surveillance, le CEA-DAM a proposé de développer un système de détection des radionucléides du xénon ultra-compact et mobile, afin de pouvoir effectuer des mesures de vérification directement sur site suspect, et ainsi contourner la contrainte de dilution atmosphérique. Ces travaux présentent le développement et l'optimisation de ce système. Le système a d'abord été modélisé sur ordinateur et ses performances en terme d'efficacité de détection ont été simulées par méthode de Monte-Carlo avec le logiciel Geant4. Les mesures se font en utilisant la technique de mesure en coïncidences électron/photon. En parallèle, une chaîne d'acquisition ultra-compacte a été développée, ainsi qu'un réseau de communication permettant de synchroniser en temps les différents spectromètres numériques utilisés pour le traitement du signal (protocole IEEE 1588 PTP). Les concentrations minimales détectables de ce système sont inférieures à 5 mBq/m³ pour une acquisition de 12 h, et ce pour les quatre radionucléides du xénon d'intérêt. / As part of the Comprehensive nuclear Test Ban Treaty (CTBT), an International Monitoring System (IMS) has been developed. This network consists of several hundred measuring stations whose role is to detect the signatures of a clandestine nuclear test. Four types of measurements are carried out: seismic, hydroacoustic, infrasound and radionuclide. In the particular case of an underground nuclear test, only the radionuclide measurement is adequate to detect the explosion and quantify its yield. Four xenon radionuclides with long half-lives are produced during a nuclear test: the 131m-Xe, the 133m-Xe, the 133-Xe and the 135-Xe. A small proportion of these gases may diffuse through the cracks in the cavity and end up in the atmosphere. Due to atmospheric dilution, the concentrations of these four radionuclides are extremely low and therefore difficult to detect. In addition, atmospheric background continues to increase as these radioactive gases are also produced by medical radioisotope facilities and nuclear power plants. In order to strengthen the IMS, the CEA-DAM has proposed to develop an ultra-compact and mobile system for detecting xenon radionuclides, in order to be able to carry out verification measurements directly on site, and thus to avoid the problem of atmospheric dilution. This work presents the development and optimization of this system. The system was first modelled on a computer and its performances in terms of detection efficiency were simulated by the Monte-Carlo method using Geant4 software. Measurements are made in electron-photon coincidence mode. In parallel, an ultra-compact acquisition chain has been developed, as well as a communication network to synchronize in time the various digital spectrometers used for signal processing (IEEE 1588 PTP protocol). The minimum detectable concentrations of this system are less than 5 mBq/m³ for a 12 h acquisition, for the four xenon radionuclides of interest.

Page generated in 0.0701 seconds