Estacas escavadas com base injetada / Injected toe bored pilesMoraes, Luciene Santos de 19 July 2010 (has links)
Foram construídas bases injetadas próximas à superfície e estacas escavadas com base injetada no campo experimental de fundações do departamento de geotecnia da USP/São Carlos. As injeções de caldas de cimento portland foram realizadas como procedimento de melhoria do solo de apoio. Provas de carga estática em estruturas com e sem injeção determinaram a eficácia da solução de bases injetadas. Simultaneamente às provas de carga, houve monitoração da sucção matricial atuante no solo, dando continuidade ao extenso programa de pesquisa realizado no Campo Experimental de Fundações da USP/São Carlos no tema da colapsibilidade. / Injected elements close to surface and toe injected bored piles were built at USP/São Carlos experimental foundation field. Under the foundations, portland cement grout was injected in order to improve soil and foundation bearing capacity. Load tests measured and determined the efficacy of the solution. Along with the load tests, matric suction measurements were made, continuing the extensive research program in the USP/São Carlos experimental foundation field under the theme soil collapsibility.
|
2 |
Effects Of Fly Ash And Desulphogypsum On The Strength And Permeability Properties Of Cayirhan SoilSahin, Murat 01 January 2006 (has links) (PDF)
Ç / ayirhan soil is a collapsible soil. Collapsible soils are generally unsaturated, low-density soils with high voids between grains where the binding agents are sensitive to saturation. When exposed to water, binding agents break, soften or dissolve such that the soil grains shear against each other and reorient in denser configurations. This reconfiguration causes a net decrease in the soil mass, resulting in large and often unexpected settlements, which can totally destroy roads, underground utilities, and structures and alter surface drainage. Uses of collapsible soils as a natural construction material in fills or embankments also may cause serious stability problems.
In this study, an extensive research program was carried out to investigate some geotechnical properties such as compaction, triaxial strength, bearing ratio and permeability of collapsible soil, found in Ç / ayirhan Thermal Power Plant area, by treating with Class C fly ash and desulphogypsum (thermal power plant by-products that are to be handled for environmental reasons) in various proportions.
The study has revealed that 20% and 25% fly ash or 5% desulphogypsum treatments (by dry weight of the mixture) improve the strength and bearing characteristics of Ç / ayirhan soil.
|
3 |
Estacas escavadas com base injetada / Injected toe bored pilesLuciene Santos de Moraes 19 July 2010 (has links)
Foram construídas bases injetadas próximas à superfície e estacas escavadas com base injetada no campo experimental de fundações do departamento de geotecnia da USP/São Carlos. As injeções de caldas de cimento portland foram realizadas como procedimento de melhoria do solo de apoio. Provas de carga estática em estruturas com e sem injeção determinaram a eficácia da solução de bases injetadas. Simultaneamente às provas de carga, houve monitoração da sucção matricial atuante no solo, dando continuidade ao extenso programa de pesquisa realizado no Campo Experimental de Fundações da USP/São Carlos no tema da colapsibilidade. / Injected elements close to surface and toe injected bored piles were built at USP/São Carlos experimental foundation field. Under the foundations, portland cement grout was injected in order to improve soil and foundation bearing capacity. Load tests measured and determined the efficacy of the solution. Along with the load tests, matric suction measurements were made, continuing the extensive research program in the USP/São Carlos experimental foundation field under the theme soil collapsibility.
|
4 |
Avaliação do módulo de elasticidade, resistência de ponta e variação de volume em campo com e sem inundação em solo colapsívelBORGES, Jesce John da Silva 21 January 2016 (has links)
Submitted by Irene Nascimento (irene.kessia@ufpe.br) on 2016-06-22T16:53:27Z
No. of bitstreams: 2
license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5)
JESCE JOHN DA SILVA BORGES 2016.pdf: 8055827 bytes, checksum: 6b2c6f2d1b046abae4869d55dfd1b8c2 (MD5) / Made available in DSpace on 2016-06-22T16:53:27Z (GMT). No. of bitstreams: 2
license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5)
JESCE JOHN DA SILVA BORGES 2016.pdf: 8055827 bytes, checksum: 6b2c6f2d1b046abae4869d55dfd1b8c2 (MD5)
Previous issue date: 2016-01-21 / A investigação geotécnica é uma etapa essencial para a elaboração de projeto de engenharia. A utilização de um programa adequado minimiza os riscos. Para se avaliar o comportamento dos solos colapsíveis, é necessário utilizar técnicas de ensaios que simulem as condições a que o solo será submetido. A pesquisa tem por objetivo avaliar o módulo de elasticidade, a resistência de ponta e a variação de volume em campo de um solo colapsível do conjunto Residencial Nova Petrolina em Petrolina-PE, com e sem a inundação prévia. Para tanto, foram utilizados em campo os equipamentos Light Weight Deflectometer – LWD, Expansocolapsômetro, Penetrômetro Dinâmico Ligeiro (Dynamic Probing Light – DPL), Penetrômetro Estático (PE) e a caracterização física do solo foi realizada em laboratório. O solo é preponderantemente arenoso, sua resistência de ponta cresce com a profundidade, chegando a um valor médio de 12,85 MPa para profundidade de 1,20 m, a inundação reduz a resistência em torno de 84%. O módulo de elasticidade varia de 46,3 a 79,2 MPa e a inundação causa uma redução de 88%. A inundação provocou uma redução na tensão de ruptura em 36%. Há uma boa correlação (R²>0,80) entre o módulo de elasticidade obtido com o LWD e o índice de resistência a penetração dinâmica (DPL). A partir dos resultados do LWD, estabeleceu-se um critério de identificação de solo colaspível através do coeficiente KLWD, atestando que o solo de Petrolina apresenta suscetibilidade ao colapso: alto para KLWD > 4,20, baixo para KLWD < 2,78 e médio para KLWD entre 2,78 e 4,20. Portanto, assim como os penetrômetros, a aplicação do LWD em solos colapsíveis demonstrou ser uma técnica promissora na avaliação da perda de rigidez do solo devido à inundação, como também se destaca sua praticidade na execução e obtenção de resultados imediatos sem necessidade de cálculos posteriores, permitindo uma análise em campo de forma imediata. / Geotechnical research is an essential step for the development of an engineering project. The use of a suitable research program minimizes risks. To evaluate the behavior of collapsible soils, it is necessary to use technical tests simulating the conditions in which the soil will be submitted. The research aims to evaluate the elasticity modulus, the tip resistance, the variation of volume in the collapsible soil of “Residential Nova Petrolina” in Petrolina-PE, with and without previous flood. Therefore, were used in the field the Light Weight Deflectometer equipment - LWD, Expansocolapsometer, Dynamic Probing Light - DPL, Static Penetrometer (PE) and the physical characterization of soil was performed in the laboratory. The soil is mainly sandy, the tip resistance grows with depth, reaching an average value of 12.85 MPa for a depth of 1.20 m, flooding reduces the resistance around 84%. The elasticity modulus varies from 46.3 to 79.2 MPa and flooding causes a 88% reduction. The flooding caused a reduction in the breakdown voltage by 36%. There is a good correlation (R²> 0.80) between the elasticity modulus obtained from the LWD and the dynamic penetration resistance index (DPL). From the results of the LWD, a criterion for the identification of collapsible soils was established through kLWD coefficient, attesting that Petrolina’s soil presents the following susceptibility to collapse: high to KLWD> 4.20, low to KLWD <2.78 and average for KLWD between 2.78 and 4.20. Therefore, as well as the penetrometers, the LWD application on collapsible soils proved to be a promising technique in the evaluation of soil rigidity loss due to flooding, as it also stands out for its practical implementation and for obtaining immediate results without the need for further calculations, allowing an immediate analysis.
|
5 |
Avaliação da colapsibilidade e resistência de ponta em um solo arenoso compactado de Petrolina-PE com e sem inundaçãoVERÍSSIMO, Klayde Janny da Silva 05 May 2016 (has links)
Submitted by Fabio Sobreira Campos da Costa (fabio.sobreira@ufpe.br) on 2016-12-01T14:03:53Z
No. of bitstreams: 2
license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5)
Dissertação Klayde Versão 9 - revisão final.pdf: 9120386 bytes, checksum: d27cc83b0c7db013e2bf497f74e2a430 (MD5) / Made available in DSpace on 2016-12-01T14:03:53Z (GMT). No. of bitstreams: 2
license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5)
Dissertação Klayde Versão 9 - revisão final.pdf: 9120386 bytes, checksum: d27cc83b0c7db013e2bf497f74e2a430 (MD5)
Previous issue date: 2016-05-05 / CNPQ / A colapsibilidade dos solos é um fenômeno típico de solos porosos, quando saturados
apresentam variação de volume, podendo provocar danos significativos nas obras de
engenharia, comprometendo total ou parcialmente estas obras. A ocorrência de solos
colapsíveis é observado em vários municípios do Estado de Pernambuco, e em particular
no Município de Petrolina. A investigação geotécnica e o entendimento de como se
processa o fenômeno é imprescindível para a elaboração de projetos e a diminuição de
possíveis danos às construções assentadas sobre esse tipo de solo. O objetivo desse
trabalho é avaliar a variação de volume e de resistência de ponta com e sem inundação
em solo compactado. A variação de volume devido à inundação foi avaliada utilizando
ensaios edométricos simples e duplo e a resistência de ponta por meio de penetrômetro
estático, em solo de um Conjunto Habitacional do Programa Minha Casa, Minha Vida,
localizado no Município de Petrolina-PE, nos graus de compactação de 80%, 85%, 90%
e 95% e nas umidades natural (0,22%), 4,00% e 7,00%. O solo é essencialmente arenoso
com mais de 90% de sua composição de areia, fração argilosa < 8% e praticamente sem
presença de silte. O solo é mau graduado (CU < 5%), não liquido e não plástico, se
enquadra no grupo SM (Areia Siltosa) na classificação do SUCS o valor máximo do
potencial de colapso atingido nos ensaios edométricos simples foi de 13,41% na tensão
de 640 kPa no solo com GC 80% e umidade de 4,00% e o valor mínimo foi de 0,24,00%
na tensão de 10 kPa, GC 95% e umidade de 7,00%. Os valores dos potenciais de colapso
(CP) diminuem com o acréscimo de umidade inicial e grau de compactação. A sua
resistência de ponta cresce com o aumento do grau de compactação, umidade e
profundidade, atingindo valor de 19,17 MPa para GC = 95% e umidade 7,00%. Há perda
de resistência de ponta durante o processo de inundação que depende da umidade inicial
e grau de compactação e há acréscimo, no solo saturado após o colapso. A variação de
volume e a resistência de ponta devido à variação de inundação são influenciadas pelo
grau de compactação e umidade inicial do solo. / The collapsibility soil is a typical phenomenon of porous soil when saturated present
volume variation, which can cause significant damage to the engineering works,
committing all or part of these works. The occurrence of collapsible soils is observed in
several municipalities in the state of Pernambuco, and in particular in the city of Petrolina.
Geotechnical investigation and understanding of how processes if the phenomenon is
essential for the development of the project and the reduction of possible damage to
buildings settled on this type of soil. The aim of this study is to evaluate the change in
volume and tip resistance with flooding in compacted soil. The volume change due to
flooding was assessed using single and double oedometric tests and tip resistance through
static penetrometer in soil of a housing program of the Minha Casa, Minha Vida, located
in the city of Petrolina, in degrees compretion of 80%, 85%, 90% and 95% and the natural
moisture (0.22%), 4.00% and 7.00%. The soil is mainly sandy with more than 90% of its
sand composition, clay fraction < 8% and virtually no presence of silt. The soil is poorly
Graduate (CU <5%), not liquid and not plastic, falls within the SM group (silty sand) in
classification SUCS. collapsing the maximum value of the potential in achieving simple
oedometric assays was 13.41% at 640 kPa in the ground stress to GC 80% moisture and
4.00% and the minimum value was 0, 24,00% at 10 kPa pressure, GC 95% and humidity
of 7.00%. The values of the collapse potential (CP) decrease with the initial moisture
increase and degree of compaction. Its tip resistance increases with increasing the degree
of compaction, humidity and depth, reaching a value of 19.17 MPa GC = 95% moisture
and 7.00%. There is loss of peak strength during the flooding process that depends on the
initial moisture content and degree of compaction and there is an increase in the saturated
soil after collapse. The volume change and the tip resistance due to flood variations are
influenced by the degree of compaction and soil initial moisture.
|
6 |
Comportamento de tubulões escavados a céu aberto, submetidos a carregamentos dinâmicos, em solo colapsível / not availableCampelo, Nilton de Souza 13 April 2000 (has links)
Provas de carga dinâmicas em sete tubulões, de oito metros de comprimento e 0,60 m de diâmetro de fuste, sendo quatro com 1,5 m de base alargada, são apresentadas. Resistências mobilizadas determinadas pelo PDA e pela utilização de métodos que empregam medidas de repique elástico, em particular, os métodos de CHELLIS-VELLOSO e UTO et al. (1985) são comparadas. Várias seqüências de carregamento foram efetuadas, de modo a se ter uma ideia da influência de carregamentos sucessivos no comportamento dos tubulões. Constatou-se que o método de CHELLIS-VELLOSO apresentou resultados sofríveis em relação às resistências encontradas pelas análises CAPWAP, mas que melhoram à medida que sucessivos carregamentos são impostos aos tubulões, por causa do gradual comportamento de tubulões escavados em tubulões \"cravados\", pelo acúmulo de tensões residuais de cravação. Este fato pode ser corroborado pela aplicação do Princípio de Hamilton aos tubulões, fazendo crer que a realização de um ensaio de carregamento dinâmico em elementos de fundação moldados in loco necessita de uma suficiente penetração líquida deste elemento no terreno - da ordem do seu diâmetro, se este for de seção uniforme -, ou seja, sua transformação em um elemento de comportamento \"cravado\". Em alguns tubulões, provas de carga dinâmicas foram efetuadas com o solo em estado natural e inundado, a fim de se determinar a influência da colapsibilidade na resistência mobilizada, conforme o nível de energia aplicado. Verificou-se que em um tubulão submetido a uma inundação prévia do terreno por 48 h, as resistências mobilizadas foram inferiores às encontradas nos demais, para um mesmo nível de energia, muito provavelmente pela ação deletéria da água na colapsibilidade do solo em tela. / Dynamic Loading Tests (DLT) on seven caissons 8 m length and 0,60 m shaft diameter are presented, being four caissons with 1,5 m enlarged base diameter. Mobilized resistances determined both through PDA and rebound measurement methods as CHELLIS-VELLOSO and UTO et al. (1985) are compared. SeveraI successive loadings were performed in order to obtain assessment of the influence of the loading sequence in the caisson behavior. It was observed what CHELLIS-VELLOSO method showed very poor agreement with the obtained resistances through the CAPWAP analysis. Nevertheless, it was noted what the more the caissons are submitted to successive loadings, the closer are the results between CAPWAP analysis and CHELLIS-VELLOSO method, because the cast-in-place caisson is gradually switched to a driving caisson due to driving residual stress accumulations. To allow this to happen, it is necessary to have a net set value close to the shaft diameter in caisson without enlarged base. These facts were confirmed through the application Hamilton\'s Principle to tested caissons. In some caissons DLT were performed with natural and soaked soil conditions in order to know the collapsible influence in the mobilized resistances. lt was verified what 48 hours previous soaked soil resulted in lowest resistances than observed in the other caissons to the same energy level. This fact may justify the harmful action of the water in the reduction of resistance in collapsible soils.
|
7 |
Influência da compactação no colapso de um solo arenoso / Compaction influence on sandy soil collapseCastro, Ana Patrícia Aranha [UNESP] 09 September 2016 (has links)
Submitted by Ana Patricia Aranha de Castro null (anapattydecastro@hotmail.com) on 2016-10-31T23:30:03Z
No. of bitstreams: 1
Dissertação - versão final.pdf: 28195003 bytes, checksum: 435fac9822de6fb7cd4974ec584669c3 (MD5) / Approved for entry into archive by Felipe Augusto Arakaki (arakaki@reitoria.unesp.br) on 2016-11-08T13:08:17Z (GMT) No. of bitstreams: 1
castro_apa_me_bauru.pdf: 28177458 bytes, checksum: c700fa1fa613989e5c3d829e23ebc39b (MD5) / Made available in DSpace on 2016-11-08T13:08:17Z (GMT). No. of bitstreams: 1
castro_apa_me_bauru.pdf: 28177458 bytes, checksum: c700fa1fa613989e5c3d829e23ebc39b (MD5)
Previous issue date: 2016-09-09 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A compactação dos solos é uma atividade fundamental nas obras geotécnicas e sua correta execução é capaz de promover melhorias significativas no comportamento do solo. Desse modo, o conhecimento acerca do solo e o controle dos métodos de execução são indispensáveis para o bom desempenho de uma obra. A variação da umidade do solo e, consequentemente, da sucção em campo influencia diretamente no seu comportamento quando submetido ou não a sobrecargas. O controle da compactação em campo representa a alternativa mais viável para melhoria de solos colapsíveis. Solos de aterros mal compactados podem apresentar comportamento colapsível quando inundados. Nesse contexto, esta pesquisa trata de um estudo acerca da compactação como método de melhoria de um solo colapsível arenoso proveniente da região de Bauru-SP. Ensaios de caracterização, de compactação Proctor Normal, assim como ensaios edométricos convencionais e com controle de sucção compõem o programa experimental dessa pesquisa. A partir dos resultados obtidos, constatou-se que as deformações por colapso aumentam com a redução do grau de compactação do solo. A umidade inicial do solo antes da inundação também influencia a magnitude do colapso. Solos com baixas umidades iniciais apresentam maior colapso ao serem umedecidos. Para o solo estudado, deformações por colapso são pequenas e praticamente desprezíveis para solos compactados com grau de compactação mínimo de 90%. Ensaios realizados com amostras compactadas nas mesmas condições de compacidade do solo natural no campo demonstraram que a deformabilidade do solo é afetada por sua baixa densidade e que a magnitude dos colapsos podem ser superiores àquelas obtidas para o mesmo solo em condição natural. No trabalho, uma representação mais prática da relação dos potenciais de colapso com a curva de compactação do solo é proposta. Assim, verificou-se que a compactação deve ser realizada com um controle suficientemente capaz de reduzir os
problemas advindos da colapsibilidade dos solos. / Soil compaction is an essential activity in geotechnical works and its proper execution is able to promote significant improvements in soil behavior. Thus, the knowledge of the soil and the control of implementation methods are indispensable for the good performance in work. Variation of soil moisture and, consequently, in soil suction field directly influences their behavior when submitted or not to overloads. The compaction field control is the most viable alternative for improving collapsible soils. Poorly compacted landfill soils can have collapsible behavior when flooded. In this sense, this research is a study of compaction as improvement method for a sandy collapsible soil from the region of Bauru-SP. Characterization tests, Proctor Normal compaction, as well as conventional oedometric tests and controlled suction oedometric tests are part of the research experimental program. From the results obtained, it was found that the collapse settlements increase with lower degree of compaction. The initial soil moisture before the flood also influences the magnitude of soil collapse. Soils with low initial moisture content have greater collapse when they are wet. For the studied soil, collapse settlements are small and almost negligible for soil with degree of compacted of 90%. Tests performed on samples compacted under the same conditions of natural soil compactness demonstrated that the soil deformability is affected by its low density and the collapse can be higher than the ones obtained in the same soil in natural condition. At this work, a more practical representation of the relationship of collapse potential with soil compaction curve is proposed. Thus, it was found that compaction can sufficiently reduce the problems arising from soil collapsibility with some control in process.
|
8 |
Estudo experimental do comportamento mecÃnico de estrato Silto- Argiloso (MassapÃ) para fundaÃÃes superficiais / Experimental study of the mechanical behavior of silty clay stratum (black clay) for shallow foundationsGleiber da Silva Chagas 29 April 2014 (has links)
CoordenaÃÃo de AperfeÃoamento de Pessoal de NÃvel Superior / O dimensionamento de fundaÃÃes superficiais requer definiÃÃo de forma clara e objetiva, para o solo em estudo, da capacidade de carga e a previsÃo dos recalques a que se submete a estrutura, baseando-se nas propriedades mecÃnicas obtidas por ensaios de laboratÃrio e campo. O ensaio de placa à uma das formas mais seguras para se obter essas informaÃÃes, a partir de carregamento direto, que produz, em escala reduzida, o comportamento da futura fundaÃÃo.
Os ensaios realizados nesta pesquisa foram executados em trÃs etapas: caracterizaÃÃo geotÃcnica (granulometria, determinaÃÃo da massa especÃfica, limite de consistÃncia, compactaÃÃo proctor normal e Ãndice de suporte califÃrnia (ISC)); ensaios especiais de laboratÃrio (adensamento e cisalhamento); e ensaios de campo (provas de carga).
O objetivo deste trabalho à avaliar a partir da realizaÃÃo de provas de carga diretas com solo na umidade natural e inundado, se previsÃes de potencial de colapso e expansÃo, realizadas a partir de ensaios edomÃtricos simples e duplos sÃo capazes de dar indicaÃÃes concordantes.
Foi observado que resultados de ensaios edometricos duplos, realizados no solo silto argiloso da cidade de IcÃ, proporcionaram estimativas mais concordantes para as situaÃÃes de colapso do solo. AlÃm disso, a tÃcnica da compactaÃÃo de solos problemÃticos se mostrou adequada para minorar, ou mesmo anular, problemas relacionados ao colapso e a expansÃo do solo estudado. / The design of shallow foundations requires defining clearly and objectively to the soil under study, the load capacity and the prediction of settlements that undergoes structure, based on the mechanical properties obtained from laboratory testing and field. The plaque assay is one of the safest ways to get this information from direct loading, which produces, in reduced scale, the behavior of the Future Foundation.
The tests performed in this study were performed in three steps: geotechnical characterization (particle size, density determination, consistency limits, standard Proctor compaction and California bearing ratio (ISC)​​); Special laboratory tests (density and shear); and field trials (load tests).
The objective of this study is to evaluate the evidence from conducting direct load with soil and flooded in natural moisture, if forecasts of potential collapse and expansion, made ​​from single and double edomÃtricos tests are able to give consistent evidence.
It was observed that results of double edometricos trials, conducted in silty clay soil of the city Ico, provided more consistent estimates for situations of soil collapse. Furthermore, the technique of compression problematic soils was adequate to mitigate or even nullify, problems related to the collapse and expansion of the studied soil.
|
9 |
Comportamento de tubulões escavados a céu aberto, submetidos a carregamentos dinâmicos, em solo colapsível / not availableNilton de Souza Campelo 13 April 2000 (has links)
Provas de carga dinâmicas em sete tubulões, de oito metros de comprimento e 0,60 m de diâmetro de fuste, sendo quatro com 1,5 m de base alargada, são apresentadas. Resistências mobilizadas determinadas pelo PDA e pela utilização de métodos que empregam medidas de repique elástico, em particular, os métodos de CHELLIS-VELLOSO e UTO et al. (1985) são comparadas. Várias seqüências de carregamento foram efetuadas, de modo a se ter uma ideia da influência de carregamentos sucessivos no comportamento dos tubulões. Constatou-se que o método de CHELLIS-VELLOSO apresentou resultados sofríveis em relação às resistências encontradas pelas análises CAPWAP, mas que melhoram à medida que sucessivos carregamentos são impostos aos tubulões, por causa do gradual comportamento de tubulões escavados em tubulões \"cravados\", pelo acúmulo de tensões residuais de cravação. Este fato pode ser corroborado pela aplicação do Princípio de Hamilton aos tubulões, fazendo crer que a realização de um ensaio de carregamento dinâmico em elementos de fundação moldados in loco necessita de uma suficiente penetração líquida deste elemento no terreno - da ordem do seu diâmetro, se este for de seção uniforme -, ou seja, sua transformação em um elemento de comportamento \"cravado\". Em alguns tubulões, provas de carga dinâmicas foram efetuadas com o solo em estado natural e inundado, a fim de se determinar a influência da colapsibilidade na resistência mobilizada, conforme o nível de energia aplicado. Verificou-se que em um tubulão submetido a uma inundação prévia do terreno por 48 h, as resistências mobilizadas foram inferiores às encontradas nos demais, para um mesmo nível de energia, muito provavelmente pela ação deletéria da água na colapsibilidade do solo em tela. / Dynamic Loading Tests (DLT) on seven caissons 8 m length and 0,60 m shaft diameter are presented, being four caissons with 1,5 m enlarged base diameter. Mobilized resistances determined both through PDA and rebound measurement methods as CHELLIS-VELLOSO and UTO et al. (1985) are compared. SeveraI successive loadings were performed in order to obtain assessment of the influence of the loading sequence in the caisson behavior. It was observed what CHELLIS-VELLOSO method showed very poor agreement with the obtained resistances through the CAPWAP analysis. Nevertheless, it was noted what the more the caissons are submitted to successive loadings, the closer are the results between CAPWAP analysis and CHELLIS-VELLOSO method, because the cast-in-place caisson is gradually switched to a driving caisson due to driving residual stress accumulations. To allow this to happen, it is necessary to have a net set value close to the shaft diameter in caisson without enlarged base. These facts were confirmed through the application Hamilton\'s Principle to tested caissons. In some caissons DLT were performed with natural and soaked soil conditions in order to know the collapsible influence in the mobilized resistances. lt was verified what 48 hours previous soaked soil resulted in lowest resistances than observed in the other caissons to the same energy level. This fact may justify the harmful action of the water in the reduction of resistance in collapsible soils.
|
10 |
Efeito da inundação do solo no comportamento de estacas moldadas in loco, instrumentadas, em campo experimental de Bauru-SP / The influence of soil soaking in the behavior of uncased cast in place instrumented piles at experimental test site in Bauru-SPFerreira, Cláudio Vidrih 20 May 1998 (has links)
Visando o estudo de diversos tipos de fundações implantou-se um Campo Experimental de Engenharia Civil na Unesp, campus de Bauru. Neste local foram realizados inúmeros ensaios de investigação geotécnica cujo solo é uma areia fina argilosa de baixa compacidade, com características colapsíveis, representativo de uma grande área do Estado. Neste trabalho apresentam-se os resultados de trinta provas de carga à compressão, executadas neste campo experimental em dez estacas apiloadas, sendo doze provas em estacas instrumentadas com o uso de strain-gages. Em cada estaca executaram-se três provas de carga, sendo a terceira com inundação prévia do solo, para se verificar o efeito da colapsibilidade na capacidade de carga. A instrumentação permitiu determinar a parcela de carga resistida por atrito e pela ponta da estaca. Os resultados são comparados a métodos empíricos normalmente utilizados no Brasil. Os resultados obtidos servem como subsídios para os projetistas desse tipo de fundação de uso muito freqüente no interior do estado de São Paulo. / In order to study different foundation types, the Unesp (São Paulo State University) in Bauru, created an experimental field in Civil Engineering. In this site an extensive soil investigation program were carried out. The topmost soil is a clayey fine sand with collapsible characteristic. The paper presents the results of thirty compression load tests carried out in ten uncased displacement cast in place piles (pounded piles, called apiloadas in Brazil), where twelve load tests were instrumented with electrical strain gages. In each pile three load test were conducted, two in natural condition and the third after soaking the soil, in order to evaluate the influence of the soil collapsibility in the results. The instrumentation permitted the evaluation of the ultimate bearing, the skin friction, the end-bearing stress and the load transfer distribution along the pile length. Comparation are made between results obtained and predicted by empirical methods that used SPT and CPT results. The results obtained provides the basis for a more rational design procedure and has a major interest for those who are dealing with foundation design of this type, frequently used in the interior of São Paulo State which soil is similar from a geotechnical point of view.
|