Efeito de soluções higienizadoras na retenção de cápsulas do tipo o\'ring / Effect of denture cleansers on the retention of capsules type o-ring

Pacheco, Thereza Cristina Lira 04 September 2015 (has links)
Soluções higienizadoras podem acarretar efeitos prejudiciais para as próteses, como deterioração da base da prótese e pigmentação. Porém, pouco se conhece sobre os efeitos destas na vida útil dos sistemas de retenção de uma overdenture. Deste modo, este estudo buscou avaliar se imersões diárias em clorexidina 2%, hipoclorito de sódio 1%, Corega® Tabs e água (controle) poderia acelerar a perda de retenção em attachments do tipo o´ring (S.I.N sistema de implantes®). Foram confeccionados 40 corpos de prova contendo cápsulas com anéis de borracha, simulando uma overdenture, e apenas 01 contendo o implante com o pilar o´ring. Eles foram separados em quatro grupos (n=10) e simulados noventa dias de imersões. Após, foram realizados testes de resistência à tração em uma máquina de ensaios mecânicos (MTS 810), antes e após a ciclagem com 270 ciclos, equivalentes a remoção e inserção da prótese três vezes ao dia, durante um período de três meses. Os resultados foram avaliados estatisticamente através dos testes ANOVA a dois critérios e do teste de Tukey (p≤0.05). Os valores médios (Newton) encontrados antes e após a imersão foram, respectivamente: Água - 9,482 / 6,081; Clorexidina - 9,972 / 7,390; Hipoclorito: 6,954 / 6,265 e Corega® Tabs: 12,464 / 11,121. Entre os grupos Clorexidina, Hipoclorito de sódio e Água não houve diferenças significativas. Houve diferenças estatisticamente significativas entre o grupo Corega® Tabs e os grupos controle e Hipoclorito de sódio, mas não com a Clorexidina. Assim, pôde-se concluir que soluções higienizadoras tiveram efeitos significativos na capacidade de retenção dos o´rings após o período simulado de três meses de imersão. / Denture cleansers can cause adverse effects on the prostheses, as deterioration of the denture base and pigmentation. However, little is known about its impacts on the life of an overdenture retention systems. Thus, this study sought to evaluate whether daily immersion in chlorhexidine 2%, sodium hypochlorite 1%, Corega® Tabs and water (control) would increase the retention loss in the O-ring type attachments (SIN implantes® system). Forty specimens containing capsules were made with rubber rings, simulating an overdenture, and only one containing the implant with the O-ring abutment. They were divided into four groups (n = 10) and ninety days in immersion were simulated, thereafter, conducted tensile strength tests on a testing machine (MTS - 810) before and after cycling of 270 cycles, equivalent to removal and insertion of the prosthesis three times a day for a period of three months. The results were statistically evaluated by the ANOVA two criteria and the Tukey test (p≤0.05). The mean values (Newton) found before and after immersion were: Water - 9,482 / 6,081; Chlorhexidine - 9,972 / 7,390; Hypochlorite: 6,954 / 6,265 and Corega® Tabs: 12.464 / 11.121. Among the groups chlorhexidine, sodium hypochlorite and water there were no significant differences. There were statistically significant differences between the group Corega® Tabs and controls and sodium hypochlorite groups, but not with the chlorhexidine. Thus, it concluded that denture cleansers had significant effects on retention capacity of orings after the simulated period of three months of immersion.
82

Avaliação da angulação do sulco de trabalho de dentes artificiais em relação ao plano de orientação e ao eixo de rotação vertical de lateralidade da mandíbula no articulador / Evaluation of the relationship amongst the working groove angulation of artificial teeth and the orientation plane and the vertical rotation axis of mandibular lateral translation in the articulator

Furuyama, Ricardo Jun 22 September 2006 (has links)
Na reabilitação protética, a oclusão e os movimentos mandibulares estão intrinsecamente ligados. A harmonia entre estes dois fatores torna-se indispensável para o sucesso do tratamento. Um dos conceitos sempre abordados na busca deste ideal é a relação entre os sulcos e as cúspides dos dentes com os movimentos mandibulares, onde as segundas devem passar livremente sobre os primeiros durante a movimentação mandibular. Assim, foi proposto avaliar o grau de coincidência da angulação do sulco de trabalho do primeiro molar inferior artificial, quando posicionado no arco, em relação à trajetória descrita pela cúspide mésiopalatina do primeiro molar superior em relação ao eixo de rotação vertical de lateralidade da mandíbula no articulador semi-ajustável. O autor utilizou uma metodologia que permitiu identificar esta trajetória com o auxílio de um programa de editoração gráfica. Foi possível avaliar as imagens digitais de montagens em cera de dentes artificiais em prótese totais inferiores e de seus respectivos planos de orientação posicionados em articulador. Através das imagens, localizou-se o sulco de trabalho do primeiro molar inferior, a trajetória da cúspide mésio-palatina do primeiro molar superior adotando-se o eixo de rotação vertical no centro das esferas condilares, e a perpendicular à tangente ao plano de orientação. Assim, mediu-se o ângulo formado entre a perpendicular à tangente e o sulco de trabalho e o ângulo entre a trajetória do eixo de rotação vertical e o sulco de trabalho. Os resultados mostraram que houve casos onde o sulco de trabalho coincidiu com a perpendicular à tangente do plano de orientação, nos demais casos a angulação apresentou, em média, valores baixos demonstrando que as montagens dos dentes artificiais seguiram os parâmetros adotados no plano de orientação segundo a técnica proposta. Estatisticamente, a distância intercondilar não interferiu nas médias dos ângulos entre o sulco de trabalho e a trajetória do eixo vertical de rotação. Não foi observada a coincidência entre o sulco de trabalho e a trajetória do eixo de rotação vertical, indicando que, durante a reprodução do movimento de lateralidade no articulador, ocorre interferência na excursão da cúspide mésio-palatina do primeiro molar superior. / In prosthetic rehabilitation, occlusion and mandibular movements are closely linked. Harmony between these factors is essential for treatment success. One of the main concepts approached when aiming for this goal is the relationship between teeth grooves and cuspids and mandibular movements, where cuspids must not touch grooves during these movements. Therefore, the present study proposes to evaluate the degree of coincidence of the working groove angulation from the artificial mandibular first molar, when positioned on the arch, with the trajectory traced by the mesio-palatal cuspid from the maxillary first molar during mandibular lateral translation determined by the vertical axis rotation in a semi-adjustable articulator. To identify this trajectory, the author utilized a graphical editing program. It was possible to evaluate digital images from artificial teeth mounted on wax for mandibular complete dentures, and their respective orientation planes positioned on the articulator. Through these images, the author located the working groove from the mandibular first molar, the trajectory described by the mesio-palatal cuspid from the maxillary first molar considering the vertical axis rotation at the center of the condilar spheres, and the perpendicular to the tangent of orientation plane. Thus, the angle between the perpendicular to the tangent and working groove and the angle between the trajectory of the vertical axis rotation and the working groove were measured. The results showed some cases where the working groove coincided with the perpendicular to the tangent of the orientation plane. In the remaining cases, the angulation displayed low mean values, illustrating that the mounting of artificial teeth followed the parameters adopted for the orientation plane according to the proposed technique. The distance between condoles did not significantly interfere in the mean values for the angles between the working groove and the trajectory of the vertical axis rotation. The coincidence between the working groove and the trajectory of the vertical axis rotation was not observed, indicating that, during the lateral translation movement in the articulator, there is interference in the trajectory of the maxillary first molar mesio-palatal cuspid.
83

Avaliação laboratorial de um dentifrício experimental à base de Ricinus communis para limpeza de próteses totais / Laboratory evaluation of the experimental dentifrice based on Ricinus communis for complete denture

Leite, Vanessa Maria Fagundes 04 May 2012 (has links)
O objetivo desse trabalho foi desenvolver um dentifrício experimental à base de Ricinus communis para higiene de próteses totais. Foram analisadas características físico-químicas, abrasividade e microbiológicas frente aos microrganismos Staphylococcus aureus(S.a), Escherichia coli (E.c), Streptococcus mutans (S.m), Enterococcus faecalis (E.f), Candida albicans (C.a), Candida glabrata (C.g), Bacilus subtilis (B.s). Inicialmente, foi verificada a concentração inibitória mínima (CIM) do R. communis puro a uma concentração máxima de 2,5%. A CIM de 0,0781% foi eficaz contra os microrganismos, exceto E.c. Em seguida, foram obtidos os dentifrícios experimentais a 1, 2, 5 e 10%, cuja ação antimicrobiana pelo método do poço difusão em Ágar foi avaliada em comparação com dentifrícios comerciais (Colgate, Trihydrall, e Corega Brite). Os resultados foram considerados positivos quando da presença da formação de halo. Os ensaios físico-químicos foram realizados com base na medida da densidade, pH, consistência e características reológicas. A abrasividade foi avaliada por ensaio gravimétrico e rugosidade em 30 espécimes de resina acrílica (90x30x4mm) antes e após a escovação em máquina de escovação artificial, com A Colgate, B Experimental a 10%, C - Dentu-Creme, D Trihydral e Água (controle). A ação antimicrobiana do dentifrício experimental a 10% foi analisada pelo método de formação de biofilme sobre espécimes de resina acrílica. Após a contaminação, os espécimes foram escovados manualmente por 60s com água e dentifrícios A, B, C e D (n=10) e imersos em meio de cultura líquido, o qual foi resuspenso para semeadura em meio de cultura sólido. Foram empregados controles positivo (contaminado e não escovado) e negativo (sem contaminação). Os resultados das análises físico-químicas e antimicrobiana por poço difusão em ágar foram informados em tabelas autoexplicativas. Os dados de abrasividade e análise microbiológica por formação de biofilme foram submetidos à ANOVA e teste de Tukey (p=0.05). Para o método poço difusão em ágar os dentifrícios experimentais não foram efetivos contra E.c, C.a e C.g. Os dentifrícios comerciais não apresentaram ação antimicrobiana somente contra E.c. O dentifrício B (0,0430±0,0032) promoveu perda de peso similar ao C (0,0424±0,0018) e D (0,0403±0,0022). O dentifrício A (0,0531±0,0066) promoveu a maior perda de peso. Os dentifrícios B (17,325±2,302) e A (16,573±3,282) promoveram a maior rugosidade superficial se comparados ao C (9,775±1,661) e D (7,089±3,980). A escovação com Água promoveu menores valores de rugosidade (0,000±0,006) e perda de peso (0,0003±0,0011). A atividade antimicrobiana do dentifrício B variou em função da cepa e apresentou semelhança a alguns dos dentifrícios comerciais: para E.f - B (3,66 ±0,56), A (3,82±0,83), C (2,84±0,81) e D (3,13±0,46); C.g, B (3,96±0,54), A (3,84±0,49) e D (3,35±0,59); S.a, B (4,99±0,53), A (4,78±0,72) e escovação com Água (4,86±0,43); C.a, B (3,98±0,57), A (3,76±0,78), C (3,23±0,23), Controle positivo (3,99±0,44) e Água (3,41±0,66). Para a E.c e B.s todos os dentifrícios apresentaram atividade antimicrobiana semelhante. Para o B.s, os dentifrícios também foram semelhantes ao Controle positivo e Água. Contra S.m, o dentifrício B, apresentou-se semelhante somente ao Controle positivo e Água. Novos estudos, buscando a diminuição da abrasividade e aumento da ação antimicrobiana do dentifrício Experimental, são necessários. / This study developed an experimental dentifrice based on Ricinus communis for denture cleansing. We analyzed the physico-chemical characteristics, abrasiveness and microbiological action against Staphylococcus aureus (S.a), Escherichia coli (E.c), Streptococcus mutans(S.m), Enterococcus faecalis (E.f), Candida albicans (C.a), Candida glabrata (C.g), Bacilus subtilis (B.s). Initially, the minimum inhibitory concentration (MIC) of R. communis at a 2.5% was analyzed. The MIC of 0.0781% was effective against the microorganisms, except E.c. Then, experimental dentifrices were obtained at 1, 2, 5 and 10% and antimicrobial activity was evaluated for agar well diffusion method in comparison with commercial toothpastes. (Colgate, Trihydrall, and Corega Brite). The results were considered positive when the presence of inhibition halo. The physico-chemical data were obtained with density measurement, pH, texture and rheological characteristics. The abrasiveness was assessed by gravimetric method and roughness. Thirty specimens of acrylic resin (90x30x4mm) was brushed before and after on artificial toothbrushing device with A Colgate, B Experimental at 10%, C - Dentu-Creme, D Trihydral and Water (control). The antimicrobial activity of experimental dentifrice 10% was analyzed by the method of biofilm formation on acrylic resin. After contamination, specimens were manually brushed for 60s with water and dentifrices A, B, C and D (n = 10) and immersed in liquid culture medium, which was resuspended for sowing in solid culture medium. Positive and negative controls were used. The results of physico-chemical analyses and antimicrobial activity for agar well diffusion were reported in tables. The data of abrasiveness and microbiological analysis by biofilm formation were submitted to ANOVA and Tukey test (p = 0.05). For the agar well diffusion, the experimental dentifrice wasnt effective against E.c., C.a. and C.g. The commercial dentifrices didnt show antimicrobial activity against E.c. The dentifrice B (0.0430 ± 0.0032) induced weight loss similar to the C (0.0424 ± 0.0018) and D (0.0403 ± 0.0022). The dentifrice A (0.0531 ± 0.0066) promoted greater weight loss. Dentifrices B (17.325 ± 2.302) and A (16.573 ± 3.282) promoted greater roughness compared to C (9.775 ± 1.661) and D (7.089 ± 3.980). Brushing with water promoted lower roughness (0.000 ± 0.006) and weight loss (0.0003 ± 0.0011). The antimicrobial activity of the dentifrice B varied according to the microorganism and showed similarity to some of the commercial dentifrices: for E.f. - B (3.66 ± 0.56), A (3.82 ± 0.83), C (2.84 ± 0.81) and D (3.13 ± 0.46) were similar; Cg - B (3.96 ± 0.54), A (3.84 ± 0.49) and D (3.35 ± 0.59 ) were similar; Sa - B (4.99 ± 0.53), A (4.78 ± 0.72) and brushing with water (4.86 ± 0.43) were similar; Ca - B (3.98 ± 0.57 ), A (3.76 ± 0.78), C (3.23 ± 0.23), positive control (3.99 ± 0.44) and water (3.41 ± 0.66) were similar. All toothpastes showed similar antimicrobial activity for E.c. and B.s. For B.s., dentifrices were similar to a positive control and water. Against S.m., the dentifrice B was similar only to the positive control and water. Further studies are needed in order to decrease the abrasiveness and increased antimicrobial activity of Experimental dentifrice.
84

\"Estudo comparativo da intensidade da força de mordida de próteses totais convencionais e overdentures inferiores retidas por sistema barra/clip sobre implantes\" / Comparisions of maximum bite force with mandibular conventional dentures and implant-supported overdentures

Rodrigues, Ricardo Soeiro 30 March 2007 (has links)
O objetivo da pesquisa foi comparar a intensidade da força de mordida, utilizando um gnatodinamometro em pacientes edentados que utilizam Próteses Totais superiores e Overdentures inferiores retidas por sistema barra/clipe e avaliar por meio de um questionário a satisfação geral destes pacientes após a reabilitação por próteses sobre implantes. O estudo foi desenvolvido em duas etapas: a primeira parte enfocou a mensuração da intensidade da força de mordida na região dos primeiros molares de ambos os lados, com o paciente utilizando a prótese total superior e a overdenture inferior e a repetição do exame após a remoção da barra sobre implante, tornando-se assim um paciente portador de Próteses Totais bimaxilares convencionais. Em média a intensidade máxima da força de mordida, obtida quando o paciente estava com a barra (overdenture inferior) foi de 8,9 Kgf, e quando a barra era removida (Prótese Total bimaxilar) foi de 4,8 Kgf. Ocorrendo praticamente um aumento de 100% na intensidade da força com a colocação da prótese sobre implante inferior. Já na segunda parte foi aplicado um questionário com o intuito de comparar a capacidade do paciente de mastigar certos tipos de alimentos com a prótese antiga e com a prótese sobre implante, e avaliar sua satisfação pessoal. Os resultados das respostas dos questionários demonstraram que 100% dos pacientes relataram dificuldade, com relação à mastigação de Cenoura crua e Amendoim. No entanto, com a prótese sobre implantes, mais de 91% afirmaram sentirem-se confortáveis ao mastigar esses alimentos. As porcentagens atingiram 100% para Pudim, Banana e Maçã. Com a prótese antiga, a capacidade de mastigar era reduzida, visto que notas (0) zero e (4) quatro foram atribuídas por mais de 86% dos pacientes, já com a prótese sobre implantes, a avaliação da capacidade de mastigar melhorou muito, uma vez que 100% dos pacientes atribuíram notas iguais ou superiores a 8 (oito). Desta forma pode-se concluir que a reabilitação com próteses sobre implantes em pacientes edentados, proporciona um aumento da intensidade da força de mordida em mais de 100%, ou seja, o dobro em relação a próteses Totais Convencionais. A satisfação geral, com relação ao tratamento envolvendo implantes foi excelente, uma vez que mais de 95% dos pacientes avaliaram o trabalho com notas iguais a 9 (nove) ou 10 (dez). / The objective of the research was to compare the intensity of the bite force, using an gnatodinamometer in edentulous patients that use superior complete denture and inferior Overdentures retained by clip bar system and to evaluate general satisfaction of these patients after the rehabilitation with the prostheses on implants through a questionnaire. The study was developed in two stages: the first part focused the mensuration of the intensity of the bite force in the area of the first molars on both sides, with the patient using the superior complete denture and the inferior overdenture and after the removal of the bar on implant, thus becoming a patient with a complete conventional denture. On average the maximum intensity of the bite force, obtained when the patient was with the bar (inferior overdenture) was of 8,9 Kgf, and when the bar was removed (prosthesis total bimaxilar) it was of 4,8 Kgf. notecing an increase of 100% practically in the intensity of the force with the placement of the prosthesis on inferior implant. In the second part a questionnaire was applied with the intention of comparing the capacity of the patient to chew certain types of foods with the old prosthesis and with the prosthesis on implant, and to evaluate his/her personal satisfaction. The results of the questionnaires demonstrated that 100% of the patients talked about difficulties regarding the mastication of raw carrot and peanut. However, with the prosthesis on implants, more than 91% reported to feel comfortable when chewing those foods. The percentages reached 100% for pudding, banana and apple. With the old prosthesis, the capacity to chew was reduced, as grades (0) zero and (4) four were attributed by more than 86% of the patients. As regards the prosthesis on implants, the evaluation of the capacity of chewing got much better as 100% of the patients attributed grades equal or superior to 8 (eight). This way it can be concluded that the rehabilitation with prostheses on implants in edentulous patients , provides an increase of the intensity of the bite force in more than 100%, in other words, the double in relation to conventional complete denture and the general satisfaction, regarding the treatment involving implants was great, as more than 95% of the patients evaluated the work with grades equal to 9 (nine) or 10 (ten).
85

Avaliação clínica e laboratorial do tratamento da estomatite protética através de produtos naturais / Clinical and laboratory evaluation of denture stomatitis treatment using natural products

Silva, Paulo Mauricio Batista da 25 June 2013 (has links)
O aumento da resistência aos antifúngicos convencionais e os possíveis efeitos colaterais destes fármacos têm estimulado pesquisas sobre produtos naturais com potencial antimicrobiano e baixa toxicidade. Assim, o objetivo desta pesquisa foi realizar uma avaliação clínica e laboratorial do tratamento da estomatite protética (EP) através de produtos naturais, por meio de cultura micológica quantitativa, de microscopia confocal e de análise das propriedades superficiais de uma resina acrílica. Em todas as avaliações, os grupos experimentais foram divididos de acordo com as seguintes substâncias: G1 - água destilada estéril; G2 - nistatina; G3 - extrato alcoólico de própolis a 20%; G4 - gel de Punica granatum Linné; G5 - gel de Uncaria tomentosa (Imuno-Max Gel). Para a cultura micológica quantitativa, 30 pacientes diagnosticados com EP utilizaram os seus respectivos medicamentos três vezes por dia, durante 14 dias, associados à escovação das próteses com dentifrício. Nas avaliações, foram coletados materiais das áreas eritematosas da mucosa palatina e das áreas correspondentes na prótese total superior. Este procedimento foi realizado antes do tratamento (T0), após 14 dias do início do tratamento (T1) e 30 dias após a suspensão do uso dos medicamentos (T2). Os dados obtidos foram submetidos ao teste não-paramétrico de Friedman para comparações intragrupos e ao teste de Kruskal-Wallis para comparações intergrupos. Para análise através de microscopia confocal, 30 espécimes de uma resina acrílica termopolimerizável foram inoculados com C. albicans para a formação do biofilme e, em seguida, imersos em sua respectiva droga. Os biofilmes remanescentes sobre os espécimes foram corados através de fluorocromos indicadores de viabilidade celular. Os dados obtidos foram analisados através do teste não paramétrico de Kruskal-Wallis e do pós-teste de comparação múltipla de Dunn. Para análise das propriedades superficiais, 50 espécimes de uma resina acrílica termopolimerizável foram fabricados, polidos e testados para a verificação inicial da rugosidade e da microdureza (T0). A seguir, cada espécime foi imerso na sua correspondente substância por 24 horas. Após 14 dias de imersão (T1), as propriedades superficiais dos espécimes foram novamente mensuradas. A variação intragrupos na rugosidade e na microdureza foi avaliada através do teste t pareado. A avaliação intergrupos, quanto ao efeito dos produtos testados na rugosidade e na microdureza, foi realizada através da análise de variância (ANOVA), seguida de teste de Tukey. Para todos os testes deste estudo foi considerado um nível de significância de 5% (p<0,05). De acordo com os resultados, foi possível concluir que o gel de P. granatum Linné exibiu propriedades superiores em relação aos produtos naturais testados. Esta substância apresentou um efeito mais completo, uma vez que, associada à escovação manual, proporcionou a maior redução da contaminação fúngica da mucosa palatina de pacientes com EP em longo prazo, além de promover, in vitro, a perda total da viabilidade celular e maior remoção das células fúngicas em biofilmes. Por fim, este produto não alterou significantemente, in vitro, a rugosidade e a microdureza da resina acrílica testada. / The increased resistance to conventional antifungal drugs and their possible side effects have stimulated research on natural products with antimicrobial activity and low toxicity. This study comprised a clinical and laboratory evaluation of the treatment of denture stomatitis (DS) using natural products by quantitative mycological culture, confocal microscopy and analysis of surface properties of an acrylic resin. In all evaluations, the experimental groups were divided according to the following substances: G1 - sterile distilled water; G2 - nystatin (Micostatin); G3 - 20% propolis alcoholic extract; G4 - P. granatum Linné gel; G5 - Uncaria tomentosa gel (Imuno-Max Gel). For quantitative mycological culture, 30 patients diagnosed with DS used their respective medicines three times a day for 14 days, associated with denture brushing with dentifrice. For the analysis, material was collected from erythematous areas of the palatal mucosa and from corresponding areas on the maxillary denture. This procedure was performed before treatment (T0), at 14 days after treatment onset (T1) and 30 days after interrupting the use of drugs (T2). Data were analyzed by the non-parametric Friedman test for intragroup comparisons and Kruskal-Wallis test for intergroup comparisons. For analysis by confocal microscopy, 30 specimens of a polymerized acrylic resin were inoculated with C. albicans for biofilm development and then immersed in the respective drugs. The remaining biofilms on the specimens were stained using fluorochrome indicators of cell viability. Data were analyzed by non-parametric Kruskal-Wallis test and Dunn\'s multiple comparison post-hoc test. For the analysis of surface properties, 50 specimens of polymerized acrylic resin were fabricated, polished and tested for initial verification of roughness and microhardness (T0). Then, the specimens were individually immersed in the respective drugs for 24 hours. After 14 days of immersion (T1), the surface properties of the specimens were measured again. The intragroup variation in roughness and microhardness was evaluated by the paired t-test. The intergroup evaluation as to the effect of tested products on roughness and microhardness was performed by analysis of variance (ANOVA) followed by Tukey test. All tests in this study considered a significance level of 5% (p<0.05). According to the results, it was concluded that P. granatum Linné gel exhibited superior properties compared to the natural products tested. This substance showed a more thorough effect, since it provided the greatest long-term reduction of fungal contamination of the palatal mucosa of patients with DS when associated with manual brushing, besides promoting total loss of cell viability and increased removal of fungal cells in biofilms in vitro. Finally, in vitro, this drug did not significantly change the roughness and hardness of the acrylic resin tested.
86

Avaliação laboratorial de um dentifrício experimental à base de Ricinus communis para limpeza de próteses totais / Laboratory evaluation of the experimental dentifrice based on Ricinus communis for complete denture

Vanessa Maria Fagundes Leite 04 May 2012 (has links)
O objetivo desse trabalho foi desenvolver um dentifrício experimental à base de Ricinus communis para higiene de próteses totais. Foram analisadas características físico-químicas, abrasividade e microbiológicas frente aos microrganismos Staphylococcus aureus(S.a), Escherichia coli (E.c), Streptococcus mutans (S.m), Enterococcus faecalis (E.f), Candida albicans (C.a), Candida glabrata (C.g), Bacilus subtilis (B.s). Inicialmente, foi verificada a concentração inibitória mínima (CIM) do R. communis puro a uma concentração máxima de 2,5%. A CIM de 0,0781% foi eficaz contra os microrganismos, exceto E.c. Em seguida, foram obtidos os dentifrícios experimentais a 1, 2, 5 e 10%, cuja ação antimicrobiana pelo método do poço difusão em Ágar foi avaliada em comparação com dentifrícios comerciais (Colgate, Trihydrall, e Corega Brite). Os resultados foram considerados positivos quando da presença da formação de halo. Os ensaios físico-químicos foram realizados com base na medida da densidade, pH, consistência e características reológicas. A abrasividade foi avaliada por ensaio gravimétrico e rugosidade em 30 espécimes de resina acrílica (90x30x4mm) antes e após a escovação em máquina de escovação artificial, com A Colgate, B Experimental a 10%, C - Dentu-Creme, D Trihydral e Água (controle). A ação antimicrobiana do dentifrício experimental a 10% foi analisada pelo método de formação de biofilme sobre espécimes de resina acrílica. Após a contaminação, os espécimes foram escovados manualmente por 60s com água e dentifrícios A, B, C e D (n=10) e imersos em meio de cultura líquido, o qual foi resuspenso para semeadura em meio de cultura sólido. Foram empregados controles positivo (contaminado e não escovado) e negativo (sem contaminação). Os resultados das análises físico-químicas e antimicrobiana por poço difusão em ágar foram informados em tabelas autoexplicativas. Os dados de abrasividade e análise microbiológica por formação de biofilme foram submetidos à ANOVA e teste de Tukey (p=0.05). Para o método poço difusão em ágar os dentifrícios experimentais não foram efetivos contra E.c, C.a e C.g. Os dentifrícios comerciais não apresentaram ação antimicrobiana somente contra E.c. O dentifrício B (0,0430±0,0032) promoveu perda de peso similar ao C (0,0424±0,0018) e D (0,0403±0,0022). O dentifrício A (0,0531±0,0066) promoveu a maior perda de peso. Os dentifrícios B (17,325±2,302) e A (16,573±3,282) promoveram a maior rugosidade superficial se comparados ao C (9,775±1,661) e D (7,089±3,980). A escovação com Água promoveu menores valores de rugosidade (0,000±0,006) e perda de peso (0,0003±0,0011). A atividade antimicrobiana do dentifrício B variou em função da cepa e apresentou semelhança a alguns dos dentifrícios comerciais: para E.f - B (3,66 ±0,56), A (3,82±0,83), C (2,84±0,81) e D (3,13±0,46); C.g, B (3,96±0,54), A (3,84±0,49) e D (3,35±0,59); S.a, B (4,99±0,53), A (4,78±0,72) e escovação com Água (4,86±0,43); C.a, B (3,98±0,57), A (3,76±0,78), C (3,23±0,23), Controle positivo (3,99±0,44) e Água (3,41±0,66). Para a E.c e B.s todos os dentifrícios apresentaram atividade antimicrobiana semelhante. Para o B.s, os dentifrícios também foram semelhantes ao Controle positivo e Água. Contra S.m, o dentifrício B, apresentou-se semelhante somente ao Controle positivo e Água. Novos estudos, buscando a diminuição da abrasividade e aumento da ação antimicrobiana do dentifrício Experimental, são necessários. / This study developed an experimental dentifrice based on Ricinus communis for denture cleansing. We analyzed the physico-chemical characteristics, abrasiveness and microbiological action against Staphylococcus aureus (S.a), Escherichia coli (E.c), Streptococcus mutans(S.m), Enterococcus faecalis (E.f), Candida albicans (C.a), Candida glabrata (C.g), Bacilus subtilis (B.s). Initially, the minimum inhibitory concentration (MIC) of R. communis at a 2.5% was analyzed. The MIC of 0.0781% was effective against the microorganisms, except E.c. Then, experimental dentifrices were obtained at 1, 2, 5 and 10% and antimicrobial activity was evaluated for agar well diffusion method in comparison with commercial toothpastes. (Colgate, Trihydrall, and Corega Brite). The results were considered positive when the presence of inhibition halo. The physico-chemical data were obtained with density measurement, pH, texture and rheological characteristics. The abrasiveness was assessed by gravimetric method and roughness. Thirty specimens of acrylic resin (90x30x4mm) was brushed before and after on artificial toothbrushing device with A Colgate, B Experimental at 10%, C - Dentu-Creme, D Trihydral and Water (control). The antimicrobial activity of experimental dentifrice 10% was analyzed by the method of biofilm formation on acrylic resin. After contamination, specimens were manually brushed for 60s with water and dentifrices A, B, C and D (n = 10) and immersed in liquid culture medium, which was resuspended for sowing in solid culture medium. Positive and negative controls were used. The results of physico-chemical analyses and antimicrobial activity for agar well diffusion were reported in tables. The data of abrasiveness and microbiological analysis by biofilm formation were submitted to ANOVA and Tukey test (p = 0.05). For the agar well diffusion, the experimental dentifrice wasnt effective against E.c., C.a. and C.g. The commercial dentifrices didnt show antimicrobial activity against E.c. The dentifrice B (0.0430 ± 0.0032) induced weight loss similar to the C (0.0424 ± 0.0018) and D (0.0403 ± 0.0022). The dentifrice A (0.0531 ± 0.0066) promoted greater weight loss. Dentifrices B (17.325 ± 2.302) and A (16.573 ± 3.282) promoted greater roughness compared to C (9.775 ± 1.661) and D (7.089 ± 3.980). Brushing with water promoted lower roughness (0.000 ± 0.006) and weight loss (0.0003 ± 0.0011). The antimicrobial activity of the dentifrice B varied according to the microorganism and showed similarity to some of the commercial dentifrices: for E.f. - B (3.66 ± 0.56), A (3.82 ± 0.83), C (2.84 ± 0.81) and D (3.13 ± 0.46) were similar; Cg - B (3.96 ± 0.54), A (3.84 ± 0.49) and D (3.35 ± 0.59 ) were similar; Sa - B (4.99 ± 0.53), A (4.78 ± 0.72) and brushing with water (4.86 ± 0.43) were similar; Ca - B (3.98 ± 0.57 ), A (3.76 ± 0.78), C (3.23 ± 0.23), positive control (3.99 ± 0.44) and water (3.41 ± 0.66) were similar. All toothpastes showed similar antimicrobial activity for E.c. and B.s. For B.s., dentifrices were similar to a positive control and water. Against S.m., the dentifrice B was similar only to the positive control and water. Further studies are needed in order to decrease the abrasiveness and increased antimicrobial activity of Experimental dentifrice.
87

Influência do uso de prótese total durante o sono na Síndrome de apnéia obstrutiva do sono / Influence of complete denture wear during sleep in OSAS patients

Furuyama, Ricardo Jun 01 October 2010 (has links)
A necessidade do uso da prótese total durante o sono ainda não está bem definida pela literatura, apenas algumas evidências sobre a relação entre a presença de estomatite protética e o uso contínuo das próteses. O objetivo do estudo clínico randomizado foi avaliar se o uso da prótese total durante o sono interfere ou não nos eventos obstrutivos respiratórios durante o sono. Pacientes idosos edentulos com suspeita de Síndrome da Apnéia-hipopnéia Obstrutiva do Sono (SAOS) foram selecionados. Novas próteses totais foram confeccionadas seguindo o protocolo da FOUSP. A cavidade oral foi avaliada com relação ao exame de Mallampati e a presença de reabsorção óssea. A qualidade do sono foi avaliada pelo PSQI (Pittsburgh Sleep Quality Index) e pela Escala de Sonolência Diurna de Epworth (ESS), as polissonografias foram efetuadas em laboratório especializados durante duas noites em duas situações cruzadas: pacientes dormindo com as próteses e sem as mesmas. Vinte e três pacientes foram avaliados e a média de idade foi de 69,6 ± 5,1 anos e 74% eram do sexo feminino. Os pacientes com severidade leve, apresentaram um índice de apnéia-hipopnéia (IAH) significantemente menor quando os dormiram sem as próteses totais (8,9 ± 2,4 eventos por hora) comparado quando dormiram com as próteses (16,6 ± 6,9 eventos por hora). Os pacientes do grupo moderado a severo, não apresentaram diferença estatisticamente significante entre os IAHs quando dormiram com e sem as próteses. Em uma avaliação separada na posição supina, os pacientes do grupo leve, apresentaram uma média do IAH na posição supina menor quando dormiram sem as próteses do que quando dormiram com elas, apresentando uma média de 12,7 ± 8,4 eventos por hora e 51,9 ± 28,6 eventos por hora respectivamente. Pode-se concluir que os pacientes edentulos com severidade leve de SAOS apresentaram um menor índice de apnéia-hipopnéia obstrutiva quando dormiram na posição supina sem as próteses totais. / Summary: There is no evidence based in the literature about complete denture use during sleep, only some evidences about denture stomatits association and the change in apneic events. The goal of this randomized clinical study was to asses if the complete denture wear during sleep influence apneic events and quality of sleep. Elderly edentulous Obstructive Sleep Apnea Syndrome (OSAS) patients from a complete denture clinic were enrolled and received new complete dentures. The oral condition was evaluated according to bone resorption and Mallampati exam. The sleep quality was assed by the Pittsburgh Sleep Quality Index, the Epworth Sleepiness Scale and the polysomnographys were performed at the sleep laboratory for the patients sleeping with and without dentures the dentures. Twenty-three patients were evaluated with mean age 69.6 (SD±5.1) years and 74% female. In the mild (5AHI<30) OSAS group the apnea-hypopnea index decreased significantly when patients slept without dentures (8.9±2.4) compared when patients slept with the dentures (16.6±6.9). In a separated analysis, mild group in supine position presented a mean apnea-hypopnea index significant lower when patients slept without dentures from 12.7 (SD ± 8.4) to 51.9 (SD ± 28.6) sleeping with dentures. There was no significant difference in moderate to severe patients variables. This study shows that mild OSAS edentulous patients had a lower apnea-hypopnea index when sleeping without dentures in supine position.
88

Avaliação da área de contato dos dentes artificiais em função da forma oclusal e da forma das arcadas na posição de máxima intercuspidação e nos movimentos excursivos / Measurement of occlusal area in prosthetic teeth according to tooth form, arch form and during maximum voluntary clenching and excursive movements

Mazini Neto, Paulo 08 August 2007 (has links)
Nesta pesquisa, foi analisada a área dos contatos oclusais, em posição de máxima intercuspidação e nos movimentos excursivos de protrusão e lateralidades direita e esquerda. Para tanto, foram utilizados dentes artificiais anatômicos e funcionais, nacionais e importados, montados em arcadas de formas triangular, quadrada e oval. Após o devido ajuste oclusal e, a partir das imagens digitalizadas das próteses em cera, foi realizada a mensuração das áreas demarcadas pelo papel carbono, empregando-se o software Leica Qwin&reg; 550. Os resultados, em milímetros quadrados, foram submetidos à análise estatística (ANOVA e Teste de Tukey). A partir das relações estabelecidas entre os fatores, pode-se concluir que, tanto para o modelo superior quanto para o modelo inferior, as áreas totais em MIC foram maiores que as áreas totais em protrusão. Ainda em protrusão, os segmentos posterior direito, anterior e posterior esquerdo apresentaram áreas iguais. Nos movimentos de lateralidade direita e esquerda, as áreas totais foram menores ou iguais às áreas totais obtidas em MIC. Nas lateralidades, as áreas no lado de trabalho foram maiores que as áreas no lado de balanceio. Na lateralidade direita, a área no lado de trabalho foi maior que a área direita do registro obtido em MIC. Na lateralidade esquerda, a área no lado de trabalho foi maior que a área do segmento esquerdo do registro em MIC. Na lateralidade direita, a área no lado de balanceio foi menor que a área do segmento esquerdo do registro em MIC. Na lateralidade esquerda, a área no lado de balanceio foi menor que a área do segmento direito do registro em MIC. / This study regards the measurement of occlusal area of prosthetic arches, all assembled in triangular, squared and oval arch forms, with functional prosthetic teeth from different manufacturers; occlusal area was measured during maximum voluntary clenching (MVC), protrusive and laterotrusive (right and left) movements. Following arch assembly and occlusal adjustment, occlusal contacts for MVC and eccentric movement were marked by carbon paper, and occlusal areas were measured by means of analysis of standardized digital images and appropriate software (Leica Qwin&reg; - 550). Occlusal areas were measured in square millimiters, and resulting values underwent statistical tests (ANOVA and Tukey). Statistical results showed that, for both upper and lower arches, occlusal areas during MVC were greater than during protrusion; also during protrusion, buccal tooth segments, both right and left, showed similar areas. During right and left laterotrusion, occlusal areas were smaller in comparison to MVC, and working sides presented larger areas than balancing sides. During laterotrusion to the right side, occlusal areas measured at the working side were larger than during MVC (right side), and same was observed for the left side during laterotrusion to the left. During laterotrusion to the right side, occlusal areas measured at the balancing side were smaller than during MVC (left side), and similar differences were observed during laterotrusion to the left side.
89

Avaliação dos efeitos adversos de soluções desinfetantes nas propriedades físicas e mecânicas de materiais para confecção de próteses totais / Evaluation of the adverse effects of disinfectant solutions on the physical and mechanical properties of materials for making complete dentures

Bueno, Frank Lucarini 23 January 2017 (has links)
O estudo avaliou os efeitos adversos de soluções desinfetantes sobre a dureza, alteração de cor, sorção e solubilidade, resistência à flexão, rugosidade e resistência ao impacto de uma resina acrílica e dentes artificiais. Microscopia confocal a laser foi utilizada para análise de superfície. Através da concentração inibitória mínima (CIM), utilizando o método de micro diluições, foi determinada a concentração de 0,15% para a solução de Triclosan e 0,25% para a Cloramina T. As variáveis foram mensuradas antes e após a imersão dos espécimes nas soluções. Os corpos de prova em resina acrílica termicamente ativada e os dentes artificiais foram distribuídos em grupos (n=10): GC = água destilada; GHS = Hipoclorito de sódio a 0,25%; GT = Solução de Triclosan a 0,15%; GCt = Solução de Cloramina T a 0,25%; GRc2 = solução de R. communis a 2%; GRc10 = solução de R. communis a 10%; GS = Sabonete Antisséptico. Os corpos de prova foram imersos em 100 mL de cada solução, simulando imersões diárias de 20 minutos por 5 anos. Os dados foram submetidos aos Testes ANOVA e Duncan ou ANOVA e Tukey (p=0,05). Para resina acrílica, todos os grupos diminuíram a dureza, tendo GC causado a maior diminuição (p=0,001). Nos demais grupos a diminuição da dureza foi semelhante. O grupo GRc2 apresentou a maior alteração de cor, enquanto o GCt causou a menor. Os demais grupos apresentaram valores intermediários (p=0,043). Em relação à sorção, o grupo GRc2 seguido do GC apresentaram maior valor de sorção e os grupos GT e GS, os menores. Para a solubilidade, os grupos GC, GHS, GCt, GT e GS apresentaram os maiores valores, e o grupo GRc2 seguido do GRc10 apresentou o menor valor (p=0,001). O menor valor de resistência a flexão foi verificado no GRc2, enquanto os grupos GC e GCt apresentaram os maiores valores (p=0,000). Os demais grupos apresentaram valores intermediários. Todas as soluções causaram diminuição da rugosidade exceto os grupos Rc10 e GC (p=0,001). Os grupos GS, GT e GCt apresentaram os maiores valores de resistência ao impacto, e o GRc10 apresentou o menor valor (p=0,000). Já para os dentes, houve aumento da dureza em todos os grupos, tendo os grupos GHS e GC causado maior alteração (p=0,000). Os grupos GS e GRc2 apresentaram a maior alteração de cor, enquanto os grupos GC, GCt e GT apresentaram as menores (p=0,000). Os grupos GC, GRc2 e GRc10 apresentaram os maiores valores de sorção e os grupos GT e GS os menores. Para a solubilidade, os grupos GRc10 e GRc2 apresentaram os maiores valores e os grupos GT e GS, os menores. A variação da rugosidade dos dentes indicou que todas as soluções causaram diminuição da rugosidade exceto o grupo GT. A maior variação de rugosidade foi causada pela solução de Rc10 (p=0,001). No período avaliado, todas as propriedades sofreram alterações em função das soluções de desinfecção avaliadas após simulação de imersões diárias de 20 minutos por 5 anos, porém todas as variáveis estudas apresentaram valores clinicamente aceitáveis, exceto a alteração de cor. / This study evaluated the adverse effects of disinfectant solutions on hardness, color change, sorption and solubility, flexural strength, roughness and impact strength of an acrylic resin and artificial teeth. Confocal laser microscopy was used for surface analysis. The minimum inhibitory concentration (MIC) using the microdilution method determined the concentration of 0.15% for the Triclosan solution and 0.25% for the Chloramine T. Variables were measured before and after immersion of the specimens in the solutions. The thermally activated acrylic resin specimens and the artificial teeth were distributed in groups (n = 10): GC = distilled water; GHS = 0.25% Sodium hypochlorite; GT = 0.15% Triclosan solution; GCt = 0.25% Chloramine T solution; GRc2 = 2% R. communis solution; GRc10 = 10% R. communis solution; GS = Antiseptic Soap. The specimens were immersed in 100 mL of each solution, simulating daily immersions of 20 minutes for 5 years. The data obtained were submitted to ANOVA and Duncan tests or ANOVA and Tukey tests (p = 0.05). For acrylic resin, all groups decreased hardness and GC showed the greatest decrease (p = 0.001). In the other groups the decrease in hardness was similar. The GRc2 group presented the greatest color change, while the GCt, the lowest. The other groups presented intermediate values (p = 0.043). In relation to the sorption, the GRc2 group followed by the GC presented higher sorption value and the GT and GS groups, the smaller. For solubility, GC, GHS, GCt, GT and GS presented the highest values, and the GRc2 group followed by GRc10 had the lowest value (p = 0.001). The GRc2 showed a lower value of flexural strength, while GC and GCt had the highest values (p = 0.000). The other groups presented intermediate values. All solutions caused a decrease in roughness except the groups Rc10 and GC (p = 0.001). The groups GS, GT and GCt had the highest values of impact resistance, and the GRc10 had the lowest value (p = 0.000). For the teeth, there were an increase on hardness in all groups, and the GHS and CG groups showed a greater change (p = 0.000). The GS and GRc2 groups had the highest color change, while the GC, GCt and GT groups showed the lowest (p = 0.000). The GC, GRc2 and GRc10 groups had the highest sorption values and the GT and GS groups had the lowest values. For the solubility, the GRc10 and GRc2 groups had the highest values and the GT and GS groups, the lowest. The variation of the roughness of the teeth indicated that all solutions caused a decrease in roughness except for the GT group. The highest roughness variation was caused by the Rc10 solution (p = 0.001). In the evaluated period, all the properties were altered as a function of the disinfection solutions evaluated after simulation of daily immersions of 20 minutes for 5 years, however all variables studied presented clinically acceptable values, except for color change.
90

Efetividade da irradiação por micro-ondas e da terapia fotodinâmica na inativação de micro-organismos presentes em próteses totais : estudo clínico /

Ribeiro, Daniela Garcia. January 2009 (has links)
Orientador: Ana Cláudia Pavarina / Banca: Eunice Teresinha Giampaolo / Banca: Marco Antonio Compagnoni / Banca: Cristina Kurachi / Banca: Karin Hermana Neppelenbroek / Resumo: As próteses removíveis estão em contato direto com os tecidos bucais, saliva e sangue e, ao serem removidas da cavidade bucal do paciente, podem estar contaminadas com micro-organismos patogênicos. Esses micro-organismos podem ser transmitidos aos técnicos de laboratório por contato direto ou pelos aerossóis produzidos durante o desgaste ou o polimento de próteses contaminadas. Neste caso, os micro-organismos podem ser disseminados pelo ambiente, desencadeando infecção cruzada. Assim, para prevenir a contaminação cruzada, todas as próteses devem ser desinfetadas ao serem enviadas ao laboratório e ao retornarem ao consultório. Com base nessas considerações, o presente estudo avaliou a efetividade clínica da irradiação por micro-ondas e da terapia fotodinâmica (PDT) para desinfecção de próteses totais superiores. Para os procedimentos de irradiação por micro-ondas, amostras de biofilme das próteses foram coletadas de 30 pacientes, os quais foram divididos aleatoriamente em dois grupos experimentais com 15 indivíduos cada: Grupo 1 - as próteses foram expostas às micro-ondas durante 3 minutos (650 W), Grupo 2 - as próteses foram expostas às micro-ondas durante 2 minutos (650 W). Para os tratamentos com PDT, amostras de biofilme das próteses foram coletadas de 60 pacientes, os quais foram divididos aleatoriamente em quatro grupos experimentais (n = 15 cada): Grupos I e II - as próteses foram borrifadas com 50 mg/L e 100 mg/L do Photogem® em suspensão, respectivamente; Grupos III e IV - as próteses foram tratadas com 50 mg/L e 100 mg/L de Photogem® em gel, respectivamente. Após 30 minutos de pré-irradiação, todas as 60 próteses foram expostas à luz de LED azul com potência de 37,5 J/cm2 (26 minutos). Amostras das próteses foram obtidas utilizando-se swab estéril antes (nas superfícies do lado esquerdo) e após (nas superfícies do lado direito)... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Prosthetic appliances that have been in contact with oral tissues, saliva and blood can be contaminated with pathogenic microorganisms when they are removed from the patient's mouth. These microorganisms can be transmitted to laboratory staff through direct contact with the infected denture or from aerosols that will be formed when the surfaces are ground or polished. In this case, microorganisms with varying degrees of virulence can be spread and disseminated into the air, leading to cross-infection. In order to prevent microbial cross-contamination among denture patients, all dental prostheses must be disinfected on entering and again on leaving the laboratory. Therefore, this investigation evaluated the clinical effectiveness of microwave irradiation and photodynamic therapy (PDT) on the inactivation of microorganisms present on complete dentures. For microwave irradiation procedures, biofilm samples were collected from dentures of 30 patients, who were randomly divided into two experimental groups of 15 subjects each: Group 1 - patients had their maxillary denture microwaved for 3 minutes (650 W); Group 2 - patients had their maxillary denture microwaved for 2 minutes (650 W). For PDT treatments, biofilm samples were collected from dentures of 60 patients, who were randomly divided into four experimental groups (n = 15 each): Groups I and II - patients had their maxillary denture sprayed with 50 mg/L and 100 mg/L of Photogem® suspension, respectively; Groups III and IV - patients had their maxillary denture treated with 50 mg/L and 100 mg/L of Photogem® gel, respectively. After 30 minutes of pre-irradiation, all sixty dentures were exposure to blue LED light at 37.5 J/cm2 (26 minutes). Denture samples were taken with sterile cotton swabs, before (left side surfaces) and after (right side surfaces) microwave irradiation and PDT procedures. All microbial material was diluted... (Complete abstract click electronic access below) / Doutor