Spelling suggestions: "subject:"composite steelconcrete bem"" "subject:"composite asphaltconcrete bem""
1 |
CONECTOR DE CISALHAMENTO EM PERFIL FORMADO A FRIO: ANÁLISE VIA MODELAGEM COMPUTACIONALSILVA, Paulo Henrique Menezes 14 September 2006 (has links)
Made available in DSpace on 2014-07-29T15:03:37Z (GMT). No. of bitstreams: 1
dissertacao paulo menezes.pdf: 3080026 bytes, checksum: 27fc4469f9413ad9117d4813295e9db7 (MD5)
Previous issue date: 2006-09-14 / In a composite system, a steel beam (laminated, welded or cold formed) is associated with a
concrete slab, forming a composite beam. The interaction between concrete and steel can be
mechanical, by friction or, in some cases, only by adherence. One of the major advantages of
the composite beams is the increase in strength and stiffness due to association of steel and
concrete that makes possible the reduction of the height of the structural elements, implicating
in material economy. The present research has the purpose to present a general vision of the
structural behavior of the composite steel-concrete beams and to proceed to a more detailed
study of the behavior of the shear connectors made from cold formed steel. A modeling study
of the push-out test is accomplished with the intention to find the factors that influences the
resistance and rigidity of the connection. The numerical study consists in the elaboration of a
three-dimensional numerical model to simulate the push-out test from which is obtained the
force-displacement curve, ultimate load, deformations and tensions along the connector. The
numeric results are compared with obtained experimental values of rehearsals accomplished at
laboratory for validation of the same ones. For the accomplishment of the numeric modeling
the computational program ANSYS® 6.1 was used, which uses non-linear material and
geometric Finite Element Method models. The numeric models present as variables of interest
the thickness, the height of the shear connectors made of cold formed steel and the resistance
of the concrete used in the premolded slab with reinforced concrete lattice joist. Results
showed that the thickness of the connector is the most important variable in the connection
strength, however the height of the connector also has influence in the resistance and, mainly,
in the rigidity of the connection. / Denomina-se sistema misto aço-concreto aquele no qual um perfil de aço (laminado, dobrado
ou soldado) trabalha em conjunto com uma laje de concreto, formando uma viga mista. A
interação entre o concreto e o perfil de aço pode se dar por meios mecânicos, por atrito, ou, em
alguns casos, por simples aderência. Uma das vantagens da utilização de vigas mistas em
sistemas de pisos é o acréscimo de resistência e de rigidez propiciados pela associação dos
elementos de aço e de concreto, o que possibilita a redução da altura dos elementos estruturais,
implicando em economia de material. O presente trabalho tem por finalidade apresentar uma
visão geral do comportamento estrutural das vigas mistas aço-concreto e proceder a um estudo
mais detalhado do comportamento da ligação com conectores de cisalhamento tipo U em
perfil formado a frio. É realizada a modelagem computacional do ensaio de cisalhamento
direto (push-out test) com o intuito de determinar os fatores que mais influenciam na
resistência e rigidez da ligação A modelagem computacional consiste na elaboração de um
modelo numérico tridimensional para simular o ensaio de cisalhamento direto, do qual se
obtém a curva força-deslocamento, a força última e as deformações e tensões ao longo do
conector. Os resultados numéricos são confrontados com valores experimentais obtidos de
ensaios realizados em laboratório para validação dos mesmos. Para a realização da modelagem
computacional, foi utilizado o programa comercial ANSYS® 6.1, elaborado com base no
Método dos Elementos Finitos, cujas ferramentas disponibilizadas permitem análises em
regime de não-linearidade física e geométrica. Os modelos computacionais apresentam como
variáveis de interesse a espessura e a altura do conector tipo perfil U formado a frio e a
resistência do concreto utilizado na confecção das lajes treliçadas. Os resultados obtidos
mostram que a espessura do conector é a variável que mais influência a resistência da ligação,
porém a altura do conector também tem influência na resistência e, principalmente, na rigidez
da ligação.
|
2 |
Comportamento estrutural de vigas mistas de aço e concreto com protensão externaNelsen, Anna Carolina Haiduk 11 July 2013 (has links)
Made available in DSpace on 2016-06-02T20:09:18Z (GMT). No. of bitstreams: 1
5306.pdf: 6510064 bytes, checksum: b7a3095b2eb1b62ba399cfe3a2684382 (MD5)
Previous issue date: 2013-07-11 / Financiadora de Estudos e Projetos / This report investigates the structural behavior, procedures for analysis and design of externally prestressed steel-concrete composite beams. Based upon the requirements outlined in ABNT NRB 8800:2008 for conventional composite beams and in the literature review, a systematic procedure was developed to design of externally prestressed steel-concrete composite beams requested the positive bending moment. Was analyzed the main modes of global collapse, especially the ultimate limit state design (ELU), which may occur in this type of structure. Also, elaborated a parametric study aimed to analyze the influence of variation in the level of prestressing and the eccentricity of tendons, as well as the constructive methodology (pretensioning and posttensioning) adopted for the the prestressing steel profile that makes up the of steel-concrete composite beam. The parametric study showed that in both methods the predominant failure mode occurs in 2nd Stage of construction. In models of composite beams analyzed with application of pretensioned when the tendon is positioned above the bottom flange of the profile steel the failure mode occurred for the combined bending and axial compression .As for the composite beams evaluated with posttensioned, independent of the position of the tendon, the failure mode occurred in function of the bending moment more than the allowable flexural strength. However, it is noted that the level of prestressing can be adequately calculated to ensure that there is no loss of carrying capacity of the structure. It was also observed that regardless of the constructive methodology adopted, higher eccentricities result in higher bearing capacity for the steel beam, as exposed in the literature review. While in Brazil is largely unexplored, there was widespread interest in the international literature on the subject in question and their variances, giving rise to theoretical and experimental. Also been mentioned as potential applications in the design of new structures and the renovation and rehabilitation of existing structures. / O presente trabalho discorre sobre o comportamento estrutural, procedimentos de análise e dimensionamento de vigas mistas de aço e concreto protendidas externamente. Embasado nas prescrições expostas na norma ABNT NRB 8800:2008 para vigas mistas convencionais e na revisão bibliográfica, um procedimento de cálculo foi desenvolvido para o dimensionamento de vigas mistas de aço e concreto protendidas externamente e solicitadas a momento fletor positivo. Foram analisados os principais modos de colapso globais, com destaque nos estados limites de últimos (ELU), que podem ocorrer nesse tipo de estrutura. Além disso, elaborou-se um estudo paramétrico que teve como objetivo analisar a influência da variação do nível de protensão e da excentricidade dos cabos de protensão; bem como da metodologia construtiva (pré-tração e pós-tração) adotada para a protensão do perfil de aço que compõe a viga mista de aço e concreto. O estudo paramétrico demonstrou que em ambas as metodologias o modo de colapso predominante ocorre na 2ª Etapa de construção. Nos modelos de vigas mistas analisados com aplicação de pré-tração quando o cabo está posicionado acima da mesa inferior do perfil de aço o modo de falha ocorreu por flexo-compressão. Já para as vigas mistas avaliadas com pós-tração, independe da posição do cabo, ocorre em função do momento fletor solicitante superar o momento fletor resistente da seção. No entanto, observa-se que o nível de protensão pode ser adequadamente dimensionado de maneira que não provoque a perda da capacidade de suporte da estrutura. Observou-se ainda que independente da metodologia construtiva adotada, maiores excentricidades resultam em maior capacidade resistente para a viga de aço, corroborando os estudos expostos na revisão bibliográfica. Embora no Brasil seja pouco explorado, observou-se um amplo interesse na literatura internacional sobre o tema em questão e suas variâncias, dando origem a pesquisas teóricas e experimentais. Também se aponta como potencialidades de aplicação em projetos de novas estruturas bem como na recuperação e reabilitação de estruturas existentes.
|
Page generated in 0.0835 seconds