• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 127
  • 72
  • 64
  • 23
  • 12
  • 11
  • 7
  • 4
  • 4
  • 3
  • 3
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 388
  • 388
  • 151
  • 97
  • 91
  • 64
  • 64
  • 63
  • 63
  • 62
  • 57
  • 55
  • 49
  • 42
  • 39
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
231

Avaliação da customização por desgaste de pinos pré-fabricados de fibra de vidro / Evaluation of fibre posts submitted to customization of the apical portion

Ana Regina Cervantes Dias 25 January 2012 (has links)
O objetivo deste estudo foi avaliar pinos pré-fabricados de fibra de vidro (White Post DC/FGM) submetidos à customização por desgaste da porção apical. Experimento 1: 5 pinos n. 4 foram divididos em 5 grupos (G) de acordo com o instrumento de desgaste: GA - sem desgaste, GB- mini torno industrial (Dentsply), GC - ponta diamantada n. 3195F (KG Sorensen), GD - disco de lixa de granulação média (Sof-Lex/3M/ESPE), GE- alicate (Tramontina). Observou-se a micromorfologia dos pinos em microscópio eletrônico de varredura (ZEISS/DSM 960). Experimento 2: 60 pinos de diferentes diâmetros foram divididos em 6 grupos: G0 - pinos n. 0,5, G1 - pinos n. 1, G2 - pinos n. 2, G3 - pinos n. 3, G4 - pinos n.4, G5 - pinos n. 4 com terço apical desgastado com discos de lixa até o equivalente ao terço apical dos pinos n. 2. Os pinos foram submetidos ao teste de flexão de 3 pontos na máquina de ensaios universal (Instron 5500 R), conforme ISO 10477. Experimento 3: 20 caninos humanos permanentes sofreram tratamento endodôntico e remoção das coroas clínicas padronizando 15 mm de remanescente radicular. Os dentes foram incluídos em resina acrílica com simulação do ligamento periodontal, receberam férula de 2 mm e foram divididos em 2 grupos: GI - pinos n. 4 cimentados em condutos preparados com broca equivalente ao pino (FGM), GII - pinos n. 4 customizados no terço apical cimentados em condutos preparados com brocas (FGM) equivalentes aos pinos n. 2 em 10 mm e n. 4 em 5 mm. Os pinos foram cimentados com cimento resinoso (Rely X U100/3M/ESPE), os corpos de prova receberam coroas diretas de resina composta (Enforce Core/Dentsply) padronizadas com coras de policarbonato (TDV) e foram submetidos ao teste de resistência à fratura na Instron a 45da ferramenta cilíndrica, com força de 500 N aplicada a 2 mm da incisal na face palatina/lingual, com velocidade de 0,5 mm/min até falha. O padrão de fratura foi classificado em favorável ou desfavorável. Os resultados foram tratados estatisticamente por teste de análise de variância (ANOVA, p<0,05). Os resultados dos testes de flexão e fratura foram respectivamente: G0 - 58,406,40; G1 - 83,959,43; G2- 103,4219,17; G3 - 160,7817,30; G4 - 170,4711,28; G5 - 106,3521,96; GI - 303,0262,21 e GII - 402,81131,97. O padrão de fratura foi tratado por Mann-Whitney que observou semelhança estatística entre os grupos. Concluiu-se que o desgaste de pinos de fibra de vidro com pontas diamantadas ou discos de lixa produz alterações micromorfológicas aceitáveis. O corte com alicate deve ser evitado. A customização por desgaste da porção apical de pinos de fibra de vidro diminui a resistência à flexão a valores aceitáveis. Dentes restaurados com pinos de fibra de vidro customizados por desgaste possuem resistência à fratura superior a dentes restaurados com pinos intactos. A customização por desgaste facilita a adaptação do pino ao conduto radicular e preserva a estrutura dental. / The purpose of this study was to evaluate fibre posts (White Post DC/FGM) submitted to customization of the apical portion. Experiment 1: 5 #4 posts were divided into five groups (G) and submitted to different custom adaptation treatments: GA no surface treatment, GB- industrial shaping tool (Dentsply), GC- #3195 fine diamond bur (KG Sorensen), GD- medium-grain paper discs (Sof-Lex/3M/ESPE), GE pliers (Tramontina). The micromorphology of the posts was observed in a scanning electron microscope (ZEISS/DSM 960). Experiment 2: 60 posts of different diameters were divided into six groups: G0 #0.5 posts, G1 #1 posts, G2 #2 posts, G3 - #3 posts; G4 - #4 posts and G5 #4 posts submitted to custom adaptation of the apical portion with paper discs until the diameter was equivalent to #2 posts. The posts were submitted to a 3 point bending test in a universal testing machine (Instron/5500 R), according to ISO 10477. Experiment 3: 20 freshly extracted permanent healthy human canines with similar size were endodontically treated and the crowns were removed, leaving a remaining root length of 15 mm. The teeth were embedded in acrylic resin with simulation of the periodontal ligament, received a 2 mm ferule and were divided into two groups: G1- 10 #4 posts were cemented into post spaces prepared with #4 drill (FGM) at 10 mm, G2 - 10 #4 customized posts were cemented into root spaces prepared with #2 drill (FGM) at 10 mm and #4 drill (FGM) at 5 mm. The posts were cemented with resin cement (Rely X U100/3M/ESPE), and the teeth received direct crowns of composite resin (Enforce Core/Dentsply), standardized with polycarbonate crowns (TDV). The fracture strength was measured on an Instron, at 45 degrees to the long axis of the tooth, until fracture. The 500 N cylindrical load was applied to the buccal/lingual axis 2 mm below the incisal line, at crosshead speed of 0.5 mm/min. The fracture pattern was observed and classified as favorable or unfavorable. The results were submitted to ANOVA (p<0.05). Flexural strength and resistance to fracture data were, respectively: G0 58.40+6.40; G1 83.95+9.43; G2 103.42+19.17; G3 160.78+17.30; G4- 170.47+11.28; G5 106.35+21.96;GI 303.02+62.21 and GII 402.81+131.97. Fracture patterns were statistically similar according to Mann-Whitney test. It was concluded that customization of fibre posts with diamond burs or paper discs produces acceptable micromorphological changes. The cut of the post with pliers should be avoided. Grounding of the apical portion of fibre posts reduces the flexural strength to acceptable values. Teeth restored with grounded fiber posts have grater fracture strength than teeth restored with intact posts. Grounding of the post facilitates adaptation to root walls and preserves tooth structure.
232

Misturas de chalk com cimento : estudo da rigidez, resistência e durabilidade

Hoch, Bruna Zakharia January 2017 (has links)
O chalk é uma rocha calcária formada de calcita, com até 95% de teor de carbonato de cálcio. Pode ser encontrado no oeste europeu e cobre aproximadamente 15% da área do Reino Unido. Muitas construções e obras de infraestrutura são realizadas sobre o chalk, e situações imprevisíveis ainda acontecem pela falta de conhecimento do seu comportamento geotécnico. Sem ser perturbado, o chalk é uma rocha fraca que permanece estável. Entretanto, quando esmagado, ele rompe facilmente. Estes desafios, somados à abundância deste material no Reino Unido, fez com que ele passasse a ser estudado nos últimos anos para um melhor entendimento de suas características e comportamento. Uma das formas de melhoramento do comportamento do chalk é com adição de cimento Portland ao material, desenvolvida nesta pesquisa. O chalk utilizado nos testes é da região de St. Nicholas, Kent, no Reino Unido, classificado, de acordo com a CIRIA, como A/B, com baixa a média densidade. O material foi moído em laboratório até a obtenção de um silte arenoso, com D50 de 0,035 mm. O material foi misturado com cimento Portland de alta resistência inicial, nas porcentagens 3, 5 e 7% em relação à massa de solo seco. Os resultados dos testes de compressão simples e de tração por compressão diametral e de rigidez inicial (G0) mostraram um ganho de resistência com o aumento do teor de cimento e dos pesos específicos aparentes secos nas amostras estudadas. Os dados de resistência foram analisados em função da porosidade pelo teor volumétrico de cimento (/Civ), mostrando a influência do nível de cimentação e do nível de compactação na resistência da mistura. O expoente de ajuste de 0,28 no volume de agente cimentante gerou melhores coeficientes de determinação nos resultados. Houve uma relação praticamente linear entre a rigidez inicial e a resistência à compressão simples. As curvas de rigidez ao longo do tempo mostraram uma tendência logarítmica da evolução de G0 com o tempo, para todas as amostras. Nos ensaios de durabilidade, quanto maior o peso específico e teor de cimento da amostra, menor a perda de massa. A rigidez permaneceu praticamente constante durante os 12 ciclos. / Chalk is a limestone formed by calcite, with up to 95% of calcium carbonate content. It can be found in Western Europe and it covers about 15% of the area of the United Kingdom. Many constructions and infrastructure works are carried out on chalk, and unpredictable situations still happen due to the lack of knowledge of its geotechnical behavior. Undisturbed, chalk is a weak rock that remains stable. However, when crushed, it breaks easily. These challenges, coupled with the abundance of this material in the UK, have led chalk to be studied in recent years for a better understanding of its characteristics and behavior. One of the ways of improving the chalk behavior is with the addition of Portland cement to the material, which is developed in this research. The chalk used in the testing was collected in St. Nicholas, Kent, UK, and characterised as CIRIA Grade A/B, low to medium density. The material was crushed in the laboratory until it became sandy silt, with D50 of 0.035 mm. The material was mixed with high initial strength Portland cement, at 3, 5 and 7% in relation to the dry soil mass The results of unconfined compression, traction by diametral compression and initial stiffness (G0) tests showed a gain of strength with the increase of cement content and specific dry unit weights in the studied samples. The strength data was analyzed as a function of the porosity by the volumetric content of cement (/Civ), showing the influence of the level of cementation and compaction in the strength of the mixture. The adjustment exponent of 0.28 in the cementing agent volume generated better determination coefficients in the results. There was an almost linear relationship between initial stiffness and unconfined compression strength. The stiffness versus time curves showed a logarithmic trend for the evolution of G0 with time in all samples. In the durability tests, the higher the dry unit weight and cement content of the sample, the lower the mass loss. The stiffness remained practically constant during the 12 cycles.
233

Proposição de um teste de aderência apropriado para controle tecnológico da resistência à compressão do concreto / Proposal of an appropriate bond test for the technological control of the compressive strength of the concrete

Silva, Bruno do Vale January 2014 (has links)
Esta pesquisa propõe-se estudar a viabilidade de um ensaio de aderência aço-concreto apropriado (Appropriate Bond Test - ABT) para estimativa da resistência à compressão axial do concreto, objetivando empregá-lo como complemento ao controle de qualidade do concreto armado em campo. Originalmente os autores Lorrain e Barbosa (2008) apresentaram a utilização de um ensaio de aderência apropriado, denominado APULOT, para estimar a resistência à compressão do concreto, aumentando as possibilidades de controle tecnológico do concreto armado em canteiros de obras. Os mesmos propõem uma adaptação do método pull-out test (POT) tradicional, normalizado pela RILEM CEB/FIP RC6:1983, por ser este um ensaio de baixa complexidade e de custo reduzido. Para viabilizar o uso de um ensaio de aderência apropriado como ensaio de controle tecnológico do concreto em canteiro de obras é necessário definir um padrão para o mesmo e adaptá-lo da prática experimental do laboratório para o campo. O presente trabalho buscou avaliar os seguintes parâmetros: (1) Tipo de carregamento do ensaio (pull-out e push-in); (2) Influência do tipo de configuração geométrica das barras de aço; (3) Análises da preparação, moldagem, cura e estocagem dos corpos de prova do ABT; (4) Análises quanto à execução do ABT referentes à idade de ruptura, taxa de carregamento e tipo de ruptura; (5) Implementação do ABT em canteiro de obras, avaliando a sua potencialidade de efetuar estimativas da resistência à compressão a partir dos dados da tensão de aderência. Para tanto, foram ensaiadas 26 composições de concreto de classes distintas, com idades entre 3 e 28 dias. Foram, ainda, testadas 8 configurações distintas de barras de aço com diâmetros nominais de 8 e 12,5 mm. Os resultados obtidos mostram que, sob condições padronizadas de ensaio e adotando os coeficientes adequados, a correlação entre a tensão máxima de aderência e a resistência à compressão do concreto é satisfatória, fortalecendo o propósito de consolidar este ensaio como uma alternativa complementar para controle de qualidade do concreto armado. / This research proposes a study on the feasibility of bond test steel-concrete appropriate (Appropriate Bond Test - ABT) to estimate the compressive strength of concrete, aiming to use them as a supplement in the quality control of concrete in situ. Originally the authors Lorrain and Barbosa (2008) proposed the use of a modified bond test, called APULOT to estimate the compressive strength of the concrete, increasing the possibilities for technological control of reinforced concrete on construction sites. They propose an adaptation of the traditional method pull-out test (POT), normalized by the CEB / FIP RC6: 1983, because it is a test of low complexity and low cost. To enable the use of the test as a test technological control of concrete in construction site is necessary to define a standard for yourself and adapt it practice experimental laboratory to the field. This study evaluated the following parameters: (1) Type of load test (pull-out and push-in); (2) Influence of the type of geometric configuration of steel bar; (3) Analyses of preparation, molding, curing and storage of specimens of ABT; (4) Review of the implementation of ABT on age rupture, loading rate and type of fracture; (5) Implementation of ABT in construction site, evaluating its potential to make estimates of compressive strength from the data of bond stress. Therefore, 26 different compositions of concrete classes, aged between 3 and 28 days, were tested. Were also tested 8 different configurations of steel bars with nominal diameters of 8 and 12.5 mm. The results indicate that, under standard testing and adopting the appropriate coefficients conditions, the correlation between the maximum bond stress and the compressive strength of concrete is satisfactory, strengthening the purpose of consolidating this test as a complementary alternative to quality control reinforced concrete.
234

Evaluación de la permeabilidad en diseños de concreto con el uso de aditivos SIKA WT-100 y SIKA WT-200 en obras hidráulicas de Lima Metropolitana

Gutierrez Sanchez, Juan Carlos, Salazar Ramirez, Juan Diego Ivan January 2015 (has links)
Esta tesis tiene un enfoque cuantitativo, la cual propone evaluar la influencia de la permeabilidad en diseños de concreto con el uso de aditivos Sika WT – 100 y Sika WT – 200 en obras hidráulicas de Lima Metropolitana, debido a que estas estructuras almacenan y/o conducen grandes volúmenes de agua a una velocidad determinada, y éstas al tener contacto con el agua reducen su vida útil. Los objetivos de esta tesis son determinar la profundidad de penetración de agua bajo presión bajo la Norma Europea EN 12390 – 8 y la resistencia a la compresión bajo la Norma Técnica Peruana NTP 339.034; para finalmente, determinar la permeabilidad para diseños de concreto bajo la Norma Técnica Colombiana NTC 4483. Para lograr los objetivos mencionados, se diseñó y elaboró 144 probetas cilíndricas de concreto de 10 cm de diámetro y 20 cm de altura y 48 probetas cilíndricas de concreto de 15 cm de diámetro y de altura, de las cuales fueron 64 probetas de concreto patrón (sin uso de ningún aditivo), 64 probetas de concreto con aplicación de 2% de aditivo Sika WT – 100; y 64 probetas de concreto con aplicación de 1% de aditivo Sika WT – 200. Los resultados de los diseños de concreto patrón, WT – 100 y WT – 200 con una relación agua/cemento de 0.40, con respecto a la profundidad de penetración de agua bajo presión, fueron 40, 30 y 15 mm, respectivamente. Los resultados de los diseños de concreto patrón, WT – 100 y WT – 200, con respecto a la resistencia a la compresión a los 28 días con una relación agua/cemento de 0.40, fueron 637, 621 y 632 kg/cm2, respectivamente. Según la Norma Técnica Colombiana NTC 4483 y con los resultados obtenidos, se concluye que el diseño de concreto patrón y el diseño de concreto WT – 100 alcanzan una media permeabilidad y que el diseño de concreto WT – 200 alcanza una baja permeabilidad, con una relación agua/cemento de 0.40. This thesis has a quantitative focus, that propose to evaluate the influence of permeability concrete designs with the use of admixtures Sika WT – 100 and Sika WT – 200 in Metropolitan Lima waterworks, because these structures store and lead large volumes of water at a certain speed, and when these has contact with water reduces their useful life. The objectives of this thesis are to determine the depth of penetration of water under pressure under the European Norm EN 12390-8 and compressive strength under the Peruvian Technical Norm NTP 339.034; finally, determine the permeability of concrete designs under the Colombian Technical Norm NTC 4483. To achieve these objectives, we designed and developed 144 cylindrical concrete specimens 10 cm in diameter and 20 cm high and 48 cylindrical concrete specimens 15 cm in diameter and height, which were 64 concrete specimens pattern (without use of any admixture) concrete specimens 64 with application of 2% admixture Sika WT - 100; and 64 concrete specimens with application of 1% admixture Sika WT - 200. The results of pattern, WT – 100 and WT - 200 concrete designs with a water – cement ratio of 0.40, with respect to the depth of penetration of water under pressure, were 40, 30 and 15 mm, respectively. The results of pattern, WT – 100 and WT - 200 concrete designs with a water – cement ratio of 0.40, with respect to compressive strength at 28 days, were 637, 621 and 632 kg/cm2, respectively. According to the Colombian Technical Norm NTC 4483 and the obtained results, one can conclude that the pattern concrete design and WT - 100 concrete design reach a medium permeability and concrete design WT - 200 reaches a high permeability, with a water – cement ratio of 0.40.
235

Propiedades físico mecánicas del concreto reciclado para Lima Metropolitana

Velásquez Pacco, Lucio Martin January 2015 (has links)
En la actualidad en gran parte del mundo se viene proponiendo e impulsando las políticas ambientales que puedan reducir el problema de la degradación de los recursos naturales a la que está siendo sometido el planeta. A tal efecto se plantea la realización de esta investigación para tratar de determinar el grado de influencia en las propiedades físicas del concreto fabricado con agregados reciclados procedentes de la trituración. La variable seleccionada para la investigación ha sido: el porcentaje de sustitución del agregado grueso natural por agregado grueso reciclado en la dosificación del concreto. El objetivo general de la investigación es analizar en qué medida la cantidad de agregado grueso reciclado usado en la dosificación de la mezcla influye en las propiedades mecánicas del concreto. El tipo de investigación fue básica y cualitativa, la metodología. Se usó una metodología experimental y transversal. El análisis de los resultados experimentales indican que la resistencia a la compresión y a la tracción no se ven afectadas notoriamente al reemplazar el 20% de agregado natural, en un mayor porcentaje de reemplazo , la resistencia empieza a decaer directamente proporcional a un mayor porcentaje de agregado reciclado. Today in much of the world has been proposing and promoting environmental policies that can reduce the problem of the degradation of natural resources that the planet is undergoing. For this purpose the realization of this research to try to determine the degree of influence on the physical properties of concrete made with recycled aggregate from crushing arises. The selected research variable was the percentage of coarse natural aggregate replacement by recycled coarse aggregate concrete proportions. The overall objective of the research is to analyze to what extent the amount of recycled coarse aggregate used in the dosage of the mixture influences the mechanical properties of concrete. The research was basic and qualitative methodology. An experimental and transversal approach was used. Analysis of the experimental results indicate that the compressive strength and tensile strength are not affected noticeably by replacing 20% of natural aggregate, a higher percentage replacement, resistance begins to drop directly proportional to a higher percentage of added recycling.
236

Barreiras de solos estabilizados com cal e cimento para proteção ambiental / Soil barriers chemically stabilized with lime and cement to environmental protection

Felipe de Campos Loch 16 December 2013 (has links)
Este trabalho apresenta a avaliação dos efeitos da estabilização química com cal e cimento na condutividade hidráulica e resistência à compressão de um solo arenoso proveniente da Formação Botucatu (Estado de São Paulo, Brasil), com o objetivo de obter um material menos permeável e mais resistente. O projeto e análise de experimentos foram realizados através de um planejamento fatorial 3², com duas variáveis independentes: teor de umidade e porcentagem de estabilizante, variando em três níveis cada. Foi utilizado cal hidratada CH-III, cimento Portland CP II-Z32 e água fornecida pela concessionária local. Os ensaios de condutividade hidráulica (K) foram executados em permeâmetros de carga constante. Foram realizados ensaios de resistência a compressão simples (RC) após 7 e 28 dias de cura. As amostras de solo estabilizado e natural foram compactadas na energia Proctor Normal. Na avaliação da estrutura das amostras de solo estabilizado verificou-se a alteração da matriz de poros promovida pela adição de cal e cimento. Após a obtenção dos resultados, análises estatísticas possibilitaram avaliar os efeitos das variáveis independentes sobre o K e RC. Pelo método de superfície de respostas foi possível demonstrar o comportamento das misturas e identificar a tendência de alteração das propriedades. As amostras de solo-cimento alcançaram reduções de condutividade hidráulica de até 9,5 x 10-7 m/s e o menor valor experimental de K foi de 1,4 x 10-8 m/s. Os ensaios de RC, com 28 dias de cura, apresentaram acréscimo de resistência de até 5,1 MPa e os resultados obtidos possuem uma variação, aproximadamente, entre 0,1 e 5,1 MPa. O procedimento adotado permitiu avaliar a influência dos fatores e determinar as misturas ótimas para cada estabilizante. / A laboratory study was conducted to evaluate the effects of lime and cement stabilization over the hydraulic conductivity and unconfined compressive strength of a sandy soil from Botucatu Formation (São Paulo State, Brazil) with the intend to generate a less permeable and more resistant material. The experiment was performed using the technique of factorial design 3², with the two independent variables: moisture content and stabilizer percentage, varying on three levels each. Hydraulic conductivity (K) was measured in constant-head permeameters. Unconfined compressive strength (CS) was measured after 7 and 28 days of curing. The samples of stabilized and natural soils were compacted with the normal Proctor energy. The evaluation of the stabilized soil structure verified a pore matrix modification promoted by lime and cement addition. With the results of the characterization, statistical analysis allowed to assess the effects of the variable factors on K and CS. The response surface method was used to demonstrate the hydraulic and compressive strength behavior of the stabilized soil. The soil-cement hydraulic conductivity achieved reductions up to 9.5 x 10-7 m/s and the lowest K experimental value was 1.4 x 10-8 m/s. The compressive strength, with 28 days of curing, presented an increase in CS up to 5.1 MPa and the obtained results showed a range between 0.1 and 5.1 MPa. The adopted experimental procedure allows the assessment of the variables influence and the determination of the optimal mixtures for each stabilizer.
237

Influência do tipo de argamassamento e da utilização de peças de ajuste dimensional na resistência à compressão da alvenaria de blocos de concreto / Influence of mortar bedding type and use of adjustment dimensional parts in the compressive strength of masonry of concrete blocks

Orieta Soto Izquierdo 16 March 2011 (has links)
A alvenaria estrutural destaca-se na indústria da construção civil atual pelas vantagens que apresenta em comparação com outros sistemas convencionais, devendo ainda ser estudada para um melhor aproveitamento do sistema. Este trabalho estuda a alteração de resistência de compressão em paredes de alvenaria estrutural devida ao lançamento da argamassa de assentamento apenas nas laterais dos blocos em comparação com o lançamento total e à inserção de peças de ajuste dimensional para o acerto de modulações de paredes de alvenaria. Foram realizados os ensaios experimentais correspondentes à caracterização dos materiais empregados e os ensaios de resistência à compressão das unidades, prismas e mini-paredes. Todos os materiais cumpriram com os requisitos normalizados para sua correta utilização nos testes experimentais. Os resultados dos ensaios à compressão dos elementos demonstraram que o efeito do tipo de argamassamento influenciou notavelmente na resistência à compressão da alvenaria, apresentando melhor desempenho o argamassamento total. O uso de peças de ajuste dimensional (rapaduras) não reduziu a resistência à compressão das mini-paredes. / Currently, the structural masonry still has some advantages in the construction industry as compared with conventional systems, however it should continue to be studied for a better utilization of the system. This research studies the change of compressive strength of masonry walls due to the placement of mortar only on the sides of the blocks compared to the total release; and the insertion of adjustment dimensional parts for the settlement of modulations masonry walls. The experimental tests corresponding of characterization of materials used and compressive strength tests of the units, prisms, and mini-walls were made. All materials complied with the standard requirements for its correct use in the experimental tests. The results of the compression tests of the elements demonstrated that the effect of mortar bedding type significantly influenced the compressive strength of masonry with full mortar bedding showing better performance. The use of adjustment dimensional parts did not reduce the compressive strength of mini-walls.
238

Estudo da interface bloco/graute em elementos de alvenaria estrutural / Study of the block/grout interface in concrete and clay block masonry structures

Orieta Soto Izquierdo 08 April 2015 (has links)
A construção de edifícios em alvenaria estrutural tem evoluído de maneira significativa no Brasil. Os edifícios têm se tornado cada vez mais altos, atingindo a marca de 20 pavimentos. Quanto mais altos os edifícios, maiores se tornam os níveis de compressão provenientes dos carregamentos verticais e a sua composição com as ações devidas ao vento e ao desaprumo, obrigando a um maior emprego da alvenaria estrutural armada. A aderência bloco/graute como fator limitante à capacidade do conjunto armadura/graute/bloco na absorção da compressão e tração simples ou da tração oriunda da flexão não é especificada nas normas tanto nacionais como internacionais. Este trabalho tem como objetivo principal estudar o comportamento da interface bloco/graute, tanto para blocos de concreto como cerâmicos e com a presença ou não de armadura, submetidos a solicitações que provocam tração e compressão. Recursos experimentais e numéricos foram realizados para o desenvolvimento da presente pesquisa. Foram feitos ensaios de caracterização dos materiais, dos componentes e da alvenaria, além de ensaios de \"push-out\" (empurramento) para determinar a resistência de aderência na interface graute/bloco e ensaios de \"pull-out\" (arrancamento) considerando-se a presença de barras de armadura para o estudo do comportamento do conjunto graute/bloco/armadura utilizados. Posteriormente foram realizadas modelagens computacionais no programa DIANA, que é baseado no método dos elementos finitos, para prever o comportamento estrutural dos modelos. A partir dos resultados experimentais e numéricos pôde-se concluir que existe uma boa aderência entre as paredes dos blocos de concreto e o graute, suficiente para evitar o escorregamento, sendo possível mobilizar toda a resistência de tração das barras de armadura de diâmetros usuais, desde que devidamente ancoradas. Já com os blocos cerâmicos observa-se uma menor aderência entre as paredes dos blocos e o graute, podendo ocorrer o escorregamento do material de enchimento, antes que a armadura alcance sua tensão de escoamento. O graute de maior resistência à compressão e menor fator água cimento (graute G30) apresentou maior resistência de aderência em relação ao graute mais fraco (graute G14) e de maior fator água/cimento. Quanto aos limites estabelecidos para a tensão de escoamento das armaduras, observa-se que, no caso de blocos de concreto, não deve haver restrição. Em contraposição, quanto aos blocos cerâmicos, o problema é mais complexo, cabendo a realização de mais ensaios para a confirmação de limites, com a variação de blocos e grautes. Os resultados do estudo paramétrico apontam limites que devem ser adotados no caso de diâmetro superior a 10 mm. De maneira simplificada, como ponto para futuras verificações pode-se propor: 75% para Ø 12,5 mm, 50% para Ø 16 mm e 25% para Ø 20 mm. As análises numéricas realizadas nos modelos ensaiados a push-out e pull-out representaram adequadamente o comportamentos observado em laboratório, permitindo a realização da análise paramétrica. / The construction of structural masonry buildings has evolved significantly in Brazil. The buildings have become ever higher, reaching the level of 20 floors. Higher buildings lead to lager compression levels, coming from the vertical loads combined to the horizontal actions due to wind and lack of verticality, obliging a greater use of reinforced structural masonry. The block/grout adherence is not specified in both national and international standards. This work aims to study the behavior of the block/grout interface, for both concrete and clay blocks, with and without reinforcement, submitted to tensile and compressive forces. Experimental and numerical resources were used to development of this study. The experimental program studied the masonry behavior using push-out specimens to determine the bond strength between the grout and the concrete unit, and pull-out specimens to study the behavior of the interface of the grout/block/reinforcement. Computational modelling was carried out using the FEM software Diana, which has a library with constitutive models suitable for civil engineering application, to complete the study and understand the structural behavior of the block/grout interface. The experimental results showed that there is a good bond between the concrete blocks internal faces and the grout, enough to prevent infill-slippage, and that the whole tensile strength of the usual reinforcement rebars is achieved provided they are properly anchored. Nevertheless, for clay blocks there is a low bond between the clay blocks internal faces and the grout, allowing the infill-slippage before the reinforcement bars reach their yield stress. The higher strength grout with lower water/cement ratio (grout G30) presented higher bond strength compared to the lower strength grout and higher water/cement ratio (grout G14). In the case of concrete blocks there should be no restriction limits on the yield stress of reinforcement, in a practical sense and considering other prescribed limits. In contradiction, in the case of clay blocks, additional tests should be carried out for establishing limits, with varying blocks and grouts. The parametric analysis indicates limits that should be adopted for a diameter larger than 10 mm. The authors of this research suggest 75% for Ø 12.5 mm, 50% for Ø 16 mm and 25% for Ø 20 mm as a reference point for future investigations. The numerical analysis showed that the computer models of the push-out and pull-out specimens represented adequately the behavior of the physical models, and thus can be used in parametric analysis.
239

Proposição de um teste de aderência apropriado para controle tecnológico da resistência à compressão do concreto / Proposal of an appropriate bond test for the technological control of the compressive strength of the concrete

Silva, Bruno do Vale January 2014 (has links)
Esta pesquisa propõe-se estudar a viabilidade de um ensaio de aderência aço-concreto apropriado (Appropriate Bond Test - ABT) para estimativa da resistência à compressão axial do concreto, objetivando empregá-lo como complemento ao controle de qualidade do concreto armado em campo. Originalmente os autores Lorrain e Barbosa (2008) apresentaram a utilização de um ensaio de aderência apropriado, denominado APULOT, para estimar a resistência à compressão do concreto, aumentando as possibilidades de controle tecnológico do concreto armado em canteiros de obras. Os mesmos propõem uma adaptação do método pull-out test (POT) tradicional, normalizado pela RILEM CEB/FIP RC6:1983, por ser este um ensaio de baixa complexidade e de custo reduzido. Para viabilizar o uso de um ensaio de aderência apropriado como ensaio de controle tecnológico do concreto em canteiro de obras é necessário definir um padrão para o mesmo e adaptá-lo da prática experimental do laboratório para o campo. O presente trabalho buscou avaliar os seguintes parâmetros: (1) Tipo de carregamento do ensaio (pull-out e push-in); (2) Influência do tipo de configuração geométrica das barras de aço; (3) Análises da preparação, moldagem, cura e estocagem dos corpos de prova do ABT; (4) Análises quanto à execução do ABT referentes à idade de ruptura, taxa de carregamento e tipo de ruptura; (5) Implementação do ABT em canteiro de obras, avaliando a sua potencialidade de efetuar estimativas da resistência à compressão a partir dos dados da tensão de aderência. Para tanto, foram ensaiadas 26 composições de concreto de classes distintas, com idades entre 3 e 28 dias. Foram, ainda, testadas 8 configurações distintas de barras de aço com diâmetros nominais de 8 e 12,5 mm. Os resultados obtidos mostram que, sob condições padronizadas de ensaio e adotando os coeficientes adequados, a correlação entre a tensão máxima de aderência e a resistência à compressão do concreto é satisfatória, fortalecendo o propósito de consolidar este ensaio como uma alternativa complementar para controle de qualidade do concreto armado. / This research proposes a study on the feasibility of bond test steel-concrete appropriate (Appropriate Bond Test - ABT) to estimate the compressive strength of concrete, aiming to use them as a supplement in the quality control of concrete in situ. Originally the authors Lorrain and Barbosa (2008) proposed the use of a modified bond test, called APULOT to estimate the compressive strength of the concrete, increasing the possibilities for technological control of reinforced concrete on construction sites. They propose an adaptation of the traditional method pull-out test (POT), normalized by the CEB / FIP RC6: 1983, because it is a test of low complexity and low cost. To enable the use of the test as a test technological control of concrete in construction site is necessary to define a standard for yourself and adapt it practice experimental laboratory to the field. This study evaluated the following parameters: (1) Type of load test (pull-out and push-in); (2) Influence of the type of geometric configuration of steel bar; (3) Analyses of preparation, molding, curing and storage of specimens of ABT; (4) Review of the implementation of ABT on age rupture, loading rate and type of fracture; (5) Implementation of ABT in construction site, evaluating its potential to make estimates of compressive strength from the data of bond stress. Therefore, 26 different compositions of concrete classes, aged between 3 and 28 days, were tested. Were also tested 8 different configurations of steel bars with nominal diameters of 8 and 12.5 mm. The results indicate that, under standard testing and adopting the appropriate coefficients conditions, the correlation between the maximum bond stress and the compressive strength of concrete is satisfactory, strengthening the purpose of consolidating this test as a complementary alternative to quality control reinforced concrete.
240

Desenvolvimento de painel alveolar de concreto armado pré-moldado para habitações de interesse social / Development of precast reinforced concrete hollow core slab for social housing construction

Fernando Mazzeo Grande 02 December 2009 (has links)
Este trabalho analisa, por meio de método experimental, a viabilidade de apropriar a produção de painel alveolar de concreto armado para aplicação em habitações de interesse social. Compara os processos industriais praticados para a produção deste elemento com alternativas inovadoras proporcionadas pela incorporação de fôrma interna, ou núcleo alveolar, que permite apropriar a tecnologia para aplicação em diferentes escalas conforme as características de cada empreendimento. Avalia a execução, a conectividade e o desempenho mecânico em relação à resistência à compressão do painel alveolar. Contribui com contexto de construção sustentável e o aproveitamento de resíduos industriais e conclui que o núcleo alveolar incorporado configura inovação tecnicamente viável no processo de produção do painel alveolar que pode ser utilizado em sistemas de fechamento e superestruturas (paredes portantes e lajes) em habitações. / This work analyzes the viability of appropriate the hollow core slab production for social housing construction, by means of an experimental method procedure. It compares the industrial process with innovated alternatives proportionate by internal hollow nuclear mould incorporate which provides technology appropriation for several production scales according to construction portage. Evaluate the execution, connectivity (with hydraulic and electric systems) and compressive strength of hollow core slabs. The researchs contributions is relate with the context of sustainable construction and the use of industrial waste as construction raw materials and it concludes that internal hollow nuclear mould incorporate is technically viable in hollow core slabs production´s process and this precast element could be applied in wall´s and slabs for housing construction.

Page generated in 0.111 seconds