• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 692
  • 422
  • 47
  • 43
  • 35
  • 31
  • 20
  • 18
  • 17
  • 11
  • 9
  • 7
  • 6
  • 5
  • 4
  • Tagged with
  • 1556
  • 1556
  • 670
  • 652
  • 394
  • 393
  • 267
  • 266
  • 257
  • 238
  • 191
  • 180
  • 173
  • 138
  • 137
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
101

Analysis of sexual dimorphism in human eye orbits using computed tomography

Lidstone, Laura J. 09 September 2011 (has links)
A plethora of anthropological studies have been undertaken on the skull, including many analyses of sexual dimorphism. Sexual dimorphism reflected in the eye orbits has not always demonstrated consistent or reliable results. However, recent studies (Pretorius, Steyn, & Scholtz, 2006; Ji et al., 2010) suggest some positive results utilizing geometric morphometrics to predict sex. Utilizing 97 post-mortem CT (computed tomography) scans, established morphological and metric techniques for sex determination were assessed from 3D rendered models of the crania. In addition, landmark data were collected on the orbital margin to evaluate the accuracy of sex determination using geometric morphometric techniques. Traditional methods demonstrated poor levels of accuracy for prediction of sex, however, utilizing generalised procrustes analysis and discriminant function analysis on 3D landmark data resulted in 94.95% overall accuracy. Application of recent methodological advances, including geometric morphometrics, should continue to be developed as it increases the ability to assess sexual dimorphism which will allow for greater identification of unknown remains.
102

An x-ray computed tomography polymer gel dosimetry system for complex radiation therapy treatment verification

Johnston, Holly A. 20 September 2013 (has links)
X-ray computed tomography (CT) polymer gel dosimetry (PGD) is an attractive tool for three-dimensional (3D) radiation therapy (RT) treatment verification due to the availability of CT scanners in RT clinics. Nevertheless, wide-spread use of the technique has been hindered by low signal-to-noise CT images largely resulting from gel formulations with low radiation sensitivity. However, a new gel recipe with enhanced dose sensitivity was recently introduced that shows great promise for use with CT readout. This dissertation describes development of an CT PGD system for 3D verification of RT treatments using the new gel formulation. The work is divided into three studies: gel characterization, commissioning of a multislice CT scanner and investigation of a dose rate dependence observed during gel characterization. The first component of this work examines the dosimetric properties of the new gel formulation. The response of the gel is found to be stable between 15 - 36 hours post-irradiation and excellent batch reproducibility is seen for doses between 0 - 28 Gy. A dose rate dependence is found for gels irradiated between 100 - 600 MU/min, indicating machine dose rate must be consistent for calibration and test irradiations to avoid dosimetric error. An example clinical application is also presented using an IMRT treatment verification that demonstrates the potential of the system for use in modern RT. The second component of this work focuses on commissioning a multislice CT scanner for CT PGD. A new slice-by-slice background subtraction technique is introduced to account for the anode heel effect. Additional investigations show recommendations for optimizing image quality in CT PGD using a single slice machine also apply to multislice scanners. In addition, the consistency of CT numbers across the multislice detector array is found to be excellent for all slice thicknesses. Further work is performed to assess the tube load characteristics of the scanner and develop a scanning protocol for imaging large gel volumes. Finally, images acquired throughout the volume of an unirradiated active gel show variations in CT data across each image on the order of 7 HU. However, these variations are not expected to greatly influence gel measurements as they are consistent throughout the gel volume. The third component of this work examines the dose rate dependence found during gel characterization. Studies using gel vials and 1 L cylinders indicate the response of the gel does not depend on changes in mean dose rate on the order of seconds to minutes. However, the machine dose rate remains, indicating variations in dose rate on the order of milliseconds influence the response of the gel. An attempt is made to mitigate the effect by increasing the concentration of antioxidant in the gel system but results in reduced overall response. Further work is performed to determine if self-crosslinking of one of the gel components contributes to the observed machine dose rate dependence. In summary, this dissertation has significantly advanced the field of gel dosimetry by providing a prototype CT PGD system with enhanced dose resolution for complex RT treatment verification. / Graduate / 0992 / 0495 / 0756 / holly.johnston@utsouthwestern.edu
103

Intrinsic Artefacts of Circular Cone-beam Computed Tomography

Bartolac, Steven 14 July 2009 (has links)
Circular source and detector trajectories in cone-beam computed tomography (CT) are known to collect insufficient data for accurate object reconstruction. One model predicts that the lacking information corresponds to a shift-variant cone of missing spatial frequency components in the local Fourier domain. These predictions were experimentally verified by imaging small, localized objects and observing their Fourier transforms. Measurements indicated that the internal angle of the ‘missing cone’ varies as the angle of locally intersecting x rays with respect to the horizontal plane, as expected. Object recovery was also found to depend greatly on the distribution of the object’s frequency spectrum relative to the missing cone, as predicted. Findings agreed with more anatomically relevant phantoms, which showed preferential intensity discrepancies at gradients oriented within or near the missing cone. Methods for artefact correction are in general limited to approximation unless a priori information is incorporated.
104

Intrinsic Artefacts of Circular Cone-beam Computed Tomography

Bartolac, Steven 14 July 2009 (has links)
Circular source and detector trajectories in cone-beam computed tomography (CT) are known to collect insufficient data for accurate object reconstruction. One model predicts that the lacking information corresponds to a shift-variant cone of missing spatial frequency components in the local Fourier domain. These predictions were experimentally verified by imaging small, localized objects and observing their Fourier transforms. Measurements indicated that the internal angle of the ‘missing cone’ varies as the angle of locally intersecting x rays with respect to the horizontal plane, as expected. Object recovery was also found to depend greatly on the distribution of the object’s frequency spectrum relative to the missing cone, as predicted. Findings agreed with more anatomically relevant phantoms, which showed preferential intensity discrepancies at gradients oriented within or near the missing cone. Methods for artefact correction are in general limited to approximation unless a priori information is incorporated.
105

MicroCT of Coronary Stents: Staining Techniques for 3-D Pathological Analysis

Darrouzet, Stephen 1987- 02 October 2013 (has links)
In the area of translational research, stent developers consult pathologists to obtain the best and most complete amount of data from implanted test devices in the most efficient manner. Through the use of micron-scale computed tomography along with post-fixation staining techniques in this study, full volumes of previously implanted stents have been analyzed in-situ in a non-destructive manner. The increased soft tissue contrast imparted by metal-containing stains allowed for a qualitative analysis of the vessel’s response to the implant with greater sensitivity and specificity while reducing beam-hardening artifact from stent struts. The developed staining techniques included iodine-potassium iodide, phosphomolybdic acid, and phosphotungstic acid, all of which bind to soft tissue and improve image quality through their ability to attenuate high energy X-rays. With these stains, the overall soft tissue contrast increased by up to 85 percent and contrast between medial and neointimal layers of the vessel increased by up to 22 percent. Beam hardening artifact was also reduced by up to 38 percent after staining. Acquiring data from the entirety of the stent and the surrounding tissue increased the quality of stent analysis in multiple ways. The three dimensional data enabled a comprehensive analysis of stent performance, lending information such as neointimal hyperplasia, percent stenosis, delineation of vessel wall layers, stent apposition, and stent fractures. By providing morphological data about stent deployment and host response, this method circumvents the need to make the more traditional histology slides for a morphometric analysis. These same data may also be applied to target regions of interest to ensure histology slides are cut from the optimal locations for a more in-depth analysis. The agents involved in such techniques are readily available in most pathology laboratories, are safe to work with, and allow for rapid processing of tissue. The ability to forego histology altogether or to highly focus what histology is performed on a vessel has the potential to hasten the development process of any coronary stent.
106

Corrosion Detection and Prediction Studies

Nicola, Sally 2012 August 1900 (has links)
Corrosion is the most important mechanical integrity issues the petrochemical industry has to deal with. While significant research has been dedicated to studying corrosion, it is still the leading cause of pipeline failure in the oil and gas industry. Not only is it the main contributor to maintenance costs, but also it accounts for about 15-20% of releases from the petrochemical industry and 80% of pipeline leaks. Enormous costs are directed towards fixing corrosion in facilities across the globe every year. Corrosion has caused some of the worst incidents in the history of the industry and is still causing more incidents every year. This shows that the problem is still not clearly understood, and that the methods that are being used to control it are not sufficient. A number of methods to detect corrosion exist; however, each one of them has shortcomings that make them inapplicable in some conditions, or generally, not accurate enough. This work focuses on studying a new method to detect corrosion under insulation. This method needs to overcome at least some of the shortcomings shown by the commercial methods currently used. The main method considered in this project is X-ray computed tomography. The results from this work show that X-ray computed tomography is a promising technique for corrosion under insulation detection. Not only does it detect corrosion with high resolution, but it also does not require the insulation to be removed. It also detects both internal and external corrosion simultaneously. The second part of this research is focused on studying the behavior of erosion/corrosion through CFD. This would allow for determining the erosion/corrosion rate and when it would take place before it starts happening. Here, the operating conditions that led to erosion/corrosion (from the literature) are used on FLUENT to predict the flow hydrodynamic factors. The relationship between these factors and the rate of erosion/corrosion is studied. The results from this work show that along with the turbulence and wall shear stress, the dynamic pressure imposed by the flow on the walls also has a great effect on the erosion/corrosion rate.
107

Comparison of clinical, periapical radiograph and cone beam volume tomography measurement techniques for assessing bone level changes following regenerative periodontal therapy a thesis /

Grimard, Brently Allan. January 2008 (has links)
Thesis (M.S.) --University of Texas Graduate School of Biomedical Sciences at San Antonio, 2008. / Vita. Includes bibliographical references.
108

A study using 3D cone beam computed tomography to evaluate masseter muscle morphology in observed skeletal malocclusions

Becht, Michael P. January 2009 (has links)
Thesis (M.S.)--West Virginia University, 2009. / Title from document title page. Document formatted into pages; contains viii, 88 p. : ill. (some col.). Vita. Includes abstract. Includes bibliographical references (p. 62-66).
109

Scatter correction, intermediate view estimation and dose characterization in megavoltage cone-beam CT imaging a dissertation /

Sramek, Benjamin Koerner. January 2008 (has links)
Dissertation (Ph.D.) --University of Texas Graduate School of Biomedical Sciences at San Antonio, 2008. / Vita. Includes bibliographical references.
110

Micro-imaging characterization of mouse models of metastasis

Winkelmann, Christopher Todd, January 2005 (has links)
Thesis (Ph. D.)--University of Missouri-Columbia, 2005. / The entire dissertation/thesis text is included in the research.pdf file; the official abstract appears in the short.pdf file (which also appears in the research.pdf); a non-technical general description, or public abstract, appears in the public.pdf file. Vita. "December 2005" Includes bibliographical references.

Page generated in 0.068 seconds