• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 692
  • 423
  • 47
  • 43
  • 35
  • 31
  • 20
  • 18
  • 17
  • 11
  • 9
  • 7
  • 6
  • 5
  • 4
  • Tagged with
  • 1557
  • 1557
  • 670
  • 652
  • 394
  • 393
  • 267
  • 266
  • 257
  • 238
  • 191
  • 180
  • 173
  • 138
  • 137
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
291

XCT analysis of the defect distribution and its effect on the static and dynamic mechanical properties in Ti-6Al-4V components manufactured by electron beam additive manufacture

Tammas-Williams, Samuel January 2016 (has links)
Selective electron beam melting (SEBM) is a promising powder bed Additive Manufacturing technique for near-net-shape manufacture of high-value titanium components. An extensive research program has been carried out to characterise in 3D the size, volume fraction, and spatial distribution of the pores in model samples, using X-ray computed tomography (XCT), and correlate them to the SEBM process variables. The average volume fraction of the pores (97.5 %) where fatigue cracks would initiate based on the relative stress intensity factor of all the pores. In contrast, crack growth was found to be insensitive to porosity, which was attributed to the much higher stress concentration generated by the crack in comparison to the pores. Some crack diversion was associated with the local microstructure, with prior β grain boundaries often coincident with crack diversion.
292

Computed tomography imaging of the heart

Williams, Michelle Claire January 2016 (has links)
Computed tomography imaging has revolutionised modern medicine and we can now study the body in greater detail than ever before. Cardiac computed tomography has the potential to provide information not just on coronary anatomy, but also on myocardial function, perfusion and viability. This thesis addresses the optimisation and validation of computed tomography imaging of the heart using a wide volume 320-multidetector scanner. Computed tomography coronary angiography now has diagnostic accuracy comparable to invasive coronary angiography. However, radiation dose remains an important concern. It is therefore important to minimise computed tomography radiation dose while maintaining image quality. I was able to demonstrate that iterative reconstruction and patient tailored imaging techniques led to a 39% reduction in radiation dose in computed tomography coronary angiography, while maintaining subjective and objective assessments of image quality. In addition, I demonstrated that diagnostic images can be obtained in 99% of unselected patients presenting with suspected coronary artery disease when using single heart-beat 320- multidetector computed tomography coronary angiography. Computed tomography myocardial perfusion imaging can provide additional and complementary information as compared to computed tomography coronary angiography that can aid diagnosis and management. I established both quantitative and qualitative assessment of computed tomography myocardial perfusion imaging and validated it against both a clinical “gold-standard”, fractional flow reserve during invasive coronary angiography, and a physiological “gold-standard”, positron emission tomography with oxygen-15 labelled water. Finally, I was able to show that techniques to reduce radiation dose can also be applied to computed tomography myocardial perfusion imaging, leading to a 60% reduction in radiation dose, while maintaining image quality. In my thesis, I have established that comprehensive cardiac angiographic and perfusion imaging can be performed with wide volume computed tomography in a broad generalizable population of patients with relatively low radiation exposure. These techniques provide both structural and functional assessments from a single imaging modality that are valid and readily applicable to the clinic in the assessment and management of patients with suspected coronary artery disease.
293

Avaliação da anatomia neurovascular da mandíbula por meio de tomografia computadorizada de feixe cônico / Assessment of neurovascular anatomy of the mandible through cone-beam computed tomography

Santos, Christiano de Oliveira 08 December 2010 (has links)
A prescrição crescente de exames de imagem tridimensionais em Odontologia especialmente para procedimentos cirúrgicos na mandíbula como a inserção de implantes justifica o grande interesse na reavaliação dos reparos anatômicos nas imagens obtidas por tomografia computadorizada de feixe cônico (TCFC). O reconhecimento das variações anatômicas relacionadas à neurovascularização mandibular nestas imagens é de grande importância, uma vez que injúrias a estas estruturas podem resultar em danos, complicações e insucessos cirúrgicos. Este estudo, realizado em três etapas, se propôs a avaliar aspectos relacionados à anatomia neurovascular da mandíbula em imagens de TCFC. Na primeira etapa, avaliou-se a ocorrência de FM adicionais (FMA) e suas características. A prevalência encontrada foi de 9,4% e um total de 32 FMA foi registrado. Destes, 14 possuíam diâmetro correspondente a pelo menos 50% do diâmetro do FM ipsilateral e suas localizações foram variáveis. Dois casos de ausência de FM foram relatados. Na segunda etapa os CM foram avaliados quanto à presença de CM bífidos, alças anteriores do nervo mentual (AA) e corticalização. Também foi avaliado o trabeculado ósseo na região da fóvea submandibular (FSM). A prevalência de CM bífidos foi de 19%. Dos 19 casos observados, 14 estavam associados a FMA. Três casos estavam associados a forames retromolares associados a bifurcações do CM foram observados. Entre 22% e 28% da amostra apresentava AA e de 4% a 8% apresentava extensão anterior da AA significativa, maior que 4mm. Na região da FSM observou-se um trabeculado ósseo diminuído ou ausente na maioria dos casos, associados a maior frequência de ausência de corticalização do CM. Na terceira etapa, a imagem da radiografia panorâmica foi comparada à TCFC na visualização de variações anatômicas relevantes para o planejamento de implantes na região entre os forames. Houve grande discrepância entre os métodos nas observações referentes à presença de AA, canais incisivos e FMA e estimativa de distância segura para colocação de implantes. Conclui-se que a grande variabilidade anatômica relacionada à neurovascularização da mandíbula e limitação da radiografia panorâmica em evidenciar estas variações ressaltam a importância da realização de exames seccionais como os obtidos na TCFC na avaliação pré-operatória da mandíbula, e que as imagens das diferentes reconstruções disponíveis devem ser interpretadas de forma meticulosa e individualizada. / Current increase on prescription of sectional diagnostic imaging for surgical procedures involving the mandible, such as implant placement, has brought much interest in revisiting neurovascular anatomy with cone-beam computed tomography (CBCT) technology recently. Acknowledgement of such anatomical variations is quite important due to possible injuries to these structures leading to surgical complications and failures. The present study was carried out in three phases and aimed to assess different aspects related to neurovascular anatomy of the mandible on CBCT images. For phase one, occurrence of additional mental foramina (AMF) and their features were assessed. Prevalence was 9.4% and a total of 32 AMF were found. The diameter of the AMF was at least 50% the diameter of ipsilateral MF in 14 cases. Location of AMF was quite variable. Two cases showing absence of MF were registered. For phase two, MC was evaluated regarding the presence of bifid MC, anterior loop of the mental nerve (AL), and corticalization. Additionally, the bone trabeculation in the submandibular gland fossa region (SGF) was assessed. Prevalence of bifid MC was 19% (19 cases). Most cases (n=14) was associated with AMF and 3 cases were associated with retromolar foramina. Between 22% and 28% showed AL, and 4%-8% presented anterior extension of AL bigger than 4mm. SGF region presented decreased or absent trabeculation in most cases, which were associated with more frequent absence of MC corticalization. For phase three, panoramic radiographs (PR) were compared to CBCT regarding assessment of anatomical variations relevant for implant planning. Major discrepancies between PR and CBCT observations were noted regarding presence of AL, incisive canal, and FMA, as well as estimation of safe distance for implant placement. It is concluded that major anatomical variability related to mandibular neurovascularization and limitation of PR in displaying such variations point out to the importance of sectional exams, such as CBCT, for pre-surgical planning. Furthermore, images available of different reconstructions must be evaluated carefully and on a case by case basis.
294

Quantificação e correlação do volume pulmonar de pacientes com acromegalia por meio de tomografia computadorizada e testes de função pulmonar / Quantification and correlation of lung volume in patients with acromegaly by computed tomography and pulmonary function tests

Gustavo Bittencourt Camilo 07 May 2015 (has links)
A acromegalia é uma doença multissistêmica decorrente da hipersecreção do hormônio do crescimento (GH) e do fator de crescimento semelhante à insulina tipo I (IGF-I), o que resulta no crescimento somático exagerado e alterações nas proporções corporais, estando associada à considerável aumento da morbidade e mortalidade. Estima-se ainda que os problemas respiratórios contribuam com 25% de todas as mortes encontradas neste grupo de pacientes. Diferenças metodológicas entre os diversos estudos levaram ao surgimento de dados inconsistentes sobre o papel do crescimento alveolar no desenvolvimento do aumento do volume pulmonar em acromegálicos, o que reforça a importância de novos trabalhos e outras abordagens sobre o tema. Ao mesmo tempo, com o desenvolvimento tecnológico, os métodos de imagem propostos em alguns estudos foram substituídos por outros mais sensíveis como a tomografia computadorizada (TC) multislice (Q-MDCT) que garante adequada mensuração do volume pulmonar, o que proporciona diferentes tipos de comparação e análise e, ainda, permite o estudo anatômico do tórax e vias pulmonares. Nossos objetivos foram identificar os principais achados da tomografia computadorizada (TC) em pacientes acromegálicos, determinar por meio da TC de tórax o volume pulmonar e comparar os achados da densitometria pulmonar com os da função pulmonar entre pacientes acromegálicos com doença ativa e doença controlada e, secundariamente, correlacionar estes achados. Foi realizado um estudo transversal com 29 portadores de acromegalia que tiveram diagnóstico da acromegalia suspeitado por características clínicas e confirmado por níveis elevados de GH não suprimido ou com níveis de IGF-I acima do limite normal. Posteriormente, os pacientes foram subdivididos nos grupos doença ativa(11 indivíduos) e doença controlada(18 indivíduos), segundo os níveis séricos de IGF-I. Houve ainda um grupo controle (17 indivíduos) em que os pacientes, após já terem realizado TC de tórax por alguma razão, foram convidados à realizar os testes de função pulmonar. A Q-MDCT e os testes de função pulmonar apresentaram excelente correlação: o volume total do pulmão (VTP) medido na TC inspiratória apresentou correlação significante com a capacidade pulmonar total (rs=0,742, p=0,0001), enquanto VTP medido na TC expiratória apresentou correlação significante com a capacidade residual funcional (rs=0,606, p=0,0005). Os pacientes acromegálicos com doença ativa apresentaram pulmões mais pesados em relação aos controles [885 (723994) vs. 696 (599769) g, p=0.017]. Os pacientes com acromegalia ativa também apresentaram maiores quantidades de compartimentos pobremente aerados em relação aos outros dois grupos, sendo esta diferença observada em %VTP [3,25 (2,553,46) vs. 2,24 (1,702,56) vs. 1,70 (1,452,15), p = 0,001] e g [82,6 (75,4 100,2) vs. 63,9 (49,180,3) vs. 54,2 (42,259,2), p = 0,0001]. O compartimento pobremente aerado medido na TC inspiratória apresentou correlação significante com os níveis de GH e IGF (rs=0,407, p=0,029; rs=0,467, p=0,011, respectivamente). Em conclusão, a Q-MDCT mostra que os pacientes acromegálicos com doença ativa apresentam pulmões mais pesados e maiores quantidades de compartimentos não aerados e pobremente aerados. Há relações entre os achados da densitovolumetria pulmonar e os parâmetros dos testes de função pulmonar na acromegalia.
295

Aspectos radiográficos e tomográficos de felinos (Felis catus - Linnaeus, 1775) adultos acometidos por rinite e sinusite /

Zanatta, Rosana. January 2007 (has links)
Orientador: Júlio Carlos Canola / Banca: Fabrício Singaretti de Oliveira / Banca: Márcia Rita Fernandes Machado / Resumo: Doenças sinonasais são comuns em pequenos animais, todavia o diagnóstico definitivo é difícil de ser estabelecido pela similaridade dos sinais clínicos das enfermidades que acometem a cavidade nasal e os seios paranasais, além da limitação dos métodos de diagnóstico. A imagem adquirida com a radiografia apresenta sobreposição de estruturas anatômicas. A tomografia computadorizada (TC) permite o estudo do corpo em planos, onde as estruturas internas podem ser visibilizadas diretamente. Estudos em que foram comparadas as imagens radiográficas e de TC da cabeça de gatos, em sua maioria, confrontaram dados de tomografias arquivadas com achados radiográficos de exames feitos em grupos distintos de animais. Com este estudo objetivou-se descrever os achados radiográficos e tomográficos de imagens obtidas da cabeça de um grupo de dez gatos mestiços, adultos, com sinais clínicos crônicos de rinite e sinusite. As alterações visibilizadas nas imagens radiográficas e de TC foram aumento de opacidade dos seios frontais e da cavidade nasal e envolvimento de estruturas extra sinonasais. Foram observados ainda nas imagens de TC desvio do septo nasal e destruição de turbinados nasais e de ossos da face. O reduzido comprimento facial do gato, associado à sobreposição de tecidos que ocorre nas radiografias de cabeça, limitam a avaliação da cavidade nasal, seios frontais e bulas timpânicas. Entretanto, o conhecimento anatomoradiográfico da cabeça permite identificar a maioria das alterações encontradas no exame de TC. / Abstract: Sinonasal diseases are common in small animals, however is difficult to establish a definitive diagnosis due clinical signals are similar in different diseases of nasal cavity and paranasal sinuses and the diagnostic methods are limited. The image acquired with the radiographic presents overlapping of anatomical structures. Computed tomography (CT) is a technique that allows the study of the body in slices, generating images without overlapping of anatomical structures. Studies have compared radiographic and CT images of feline head, however radiographic and CT images were acquire to different groups of animals. The aim of this study was to describe the aspects of radiographic and tomographic images acquired to the head of a group of ten adults mixed-breed mixed-breed cats, with chronic signals of rhinitis and sinusitis. The findings in radiographic and CT images in this study were opacification of frontal sinuses and nasal cavity, and extrasinonasal involvement. In CT, were observed nasal septal deviation, turbinate destruction and nasal bony changes. The small facial length of the cat, associated with tissue superimposition that commonly occurs in head radiographs, restrict nasal cavity, frontal sinus and timpanic bullae evaluation. However, the anatomoradiographic knowledge of the head allows the identification of most alterations found at CT examination. / Mestre
296

Avaliação da posição e morfologia condilar relacionados aos sinais e sintomas de DTMs em pacientes submetidos a cirurgia ortognática /

Pellizzaro, Delise. January 2017 (has links)
Orientador: Guilherme Monteiro Tosoni / Resumo: O presente trabalho teve como objetivo avaliar, por meio de TCFC, a posição, angulação e aspectos morfológicos dos processos condilares relacionados aos sinais e sintomas das disfunções temporomandibulares (DTMs) pré e pós cirurgia ortognática. Foram selecionados 17 pacientes, com deformidades dentofaciais (Classe II e III de Angle) que estivessem em tratamento ortodôntico e com indicação para cirurgia ortognática. Imagens de tomografia computadorizada de feixe cônico (TCFC) foram utilizadas para análise da posição, angulação e aspectos morfológicos dos processos condilares nas reconstruções axial, coronal e sagital, em três tempos: pré-operatório; 15 e 180 dias após a realização da cirurgia. Para a avaliação dos sinais e sintomas de DTMs, os pacientes foram avaliados pelo questionário padrão Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD), sendo aplicado em dois tempos: pré-operatório e 180 dias. As imagens foram analisadas independentemente por 2 radiologistas previamente calibrados (correlação de Pearson de 0,641 para variáveis numéricas e nível de concordância de 68,63% para variáveis dicotômicas). Diferença estatística foi observada nos ângulos axial direito e coronal medial esquerdo entre o pré-operatório vs 180 dias e na distância condilar posterior do lado esquerdo, na reconstrução sagital entre pré-operatório vs 15 dias e 15 dias vs 180 dias. A presença de novos defeitos condilares foram observados em 3 pacientes após 180 dias. Em relação às DT... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was to evaluate the position, angulation, morphological aspects of the condylar process and signs and symptoms of temporomandibular disorders (TMDs) before and after orthognathic surgery. Seventeen patients with dentofacial deformities malocclusion (Angle Class II and III) and orthodontically treated who had referred to orthognathic surgery were selected. Cone beam computed tomography (CBCT) images were used to analyze the position, angulation and morphological aspects of the condylar process in the axial, coronal and sagittal reconstructions, in three times: preoperative; 15 days after the surgery and 180 days after the surgery. For the assessment of TMD signs and symptoms, patients were evaluated using the Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD), which was applied in two times: preoperative and 180 days. The images were analyzed independently by two radiologists previously calibrated (Pearson correlation 0.641 for numeric variables and level of agreement of 68.63% for dichotomy variables. Significant statistical difference was observed in the right and left medial coronal angles between the preoperative vs 180 days and the posterior condylar distance of the left side, in the sagittal reconstruction between preoperative vs 15 days and 15 days vs 180 days. The presence of new condylar defects was observed in 3 patients after 180 days. Regarding to TMDs, there was a significant improvement in 4 patients for muscular TMD, 6 f... (Complete abstract click electronic access below) / Doutor
297

Avaliação, por tomografia computadorizada, do envolvimento do espaço mastigador por neoplasia maligna da cabeça e pescoço, correlacionando com a presença de trismo / Evaluation by computed tomography, the involvement of the chewer a malignant neoplasm of the head and neck, correlating with the presence of trismus

Mariana Luiza Bittencourt Campinhos 05 July 2013 (has links)
Objetivo: Avaliar por meio da Tomografia Computadorizada singleslice, alterações nas estruturas do espaço mastigador, por disseminação loco-regional das neoplasias malignas originárias da loja tonsilar, trígono retromolar, seio maxilar e nasofaringe; correlacionar a presença de trismo com os achados tomográficos e dimensões do tumor. Material e métodos: foram selecionados prontuários de pacientes portadores de tumores malignos envolvendo as 4 regiões a serem estudadas, junto aos arquivos do Hospital Heliópolis. Foram excluídos os pacientes submetidos a terapêutica antineoplásica prévia ou com doenças inflamatórias ou infeciosas locais. Os prontuários foram revisados por um único examinador, onde foram coletadas informações relativas a idade, gênero, localização do tumor primário, tempo de evolução da doença, estadiamento do tumor e presença ou ausência de trismo. Após a administração do meio de contraste iodado, o protocolo de aquisição de imagens tomográficas foi de cortes axiais de 3mm de espessura, aquisições coronais foram feitas quando necessário. A análise das imagens foi feita por dois examinadores médicos, residentes do 3° de Radiologia médica, em momentos distintos, sem o conhecimento prévio das informações clínicas. Na avaliação do EM, os achados foram transcritos para uma planilha específica, considerando a presença ou ausência dos seguintes itens: simetria com o EM contralateral, obliteração do plano gorduroso, do trígono retromolar e do espaço faríngeo, edema e/ou atrofia dos músculos pterigoideos medial e lateral, destruição do ramo da mandíbula. Resultados: O trismo esteve presente em 10 pacientes estudados. Na associação entre dimensão do tumor e trismo, observamos que 90% dos pacientes apresentam tamanho T4, enquanto essa porcentagem é de 43% nos pacientes sem trismo. Analisando-se em termos de razão de chances, verificou-se que pacientes com tumores T4 apresentam uma chance de trismo de 11,6 vezes maior que as demais dimensões (T0 a T3). As neoplasias da loja tonsilar e trígono retromolar perfizeram 95% das neoplasias avaliadas. Foram encontrados apenas 3 casos de neoplasia da nasofaringe, e em nenhum deles observamos a presença de trismo, e não foi encontrado nenhum caso de neoplasia de seio maxilar. Relacionando os achados tomográficos com o grupo de pacientes com trismo, observamos que 60% dos pacientes com trismo apresentaram edema e/ou atrofia dos músculos pterigoideos na TC, enquanto que essa porcentagem foi de 21,8% nos pacientes sem trismo. Em relação às dimensões do tumor e sua relação com os achados das imagens observamos associação apenas entre tumores T4 e detecção de edema e/ou atrofia dos músculos pterigoideos, neste item pacientes com edema e/ou atrofia dos músculos pterigoideos apresentam 5,4 vezes ais chance de apresentarem trismo. Conclusões: Observamos na TC as seguintes alterações no EM: obliteração do plano gorduroso em 69,2 % dos pacientes, assimetria em 27,7%, edema/atrofia em 26,2 % dos pacientes e destruição óssea em 20%. Os graus de concordância inter examinadores foram variáveis. Encontramos associação apenas entre pacientes com trismo e edema/atrofia dos músculos pterigoideos. Neste mesmo item foi observado associação com tumores de dimensão T4. Não encontramos associação do trismo com os demais itens avaliados na TC. / Objective: Evaluate by computed tomography (CT) singleslice changes in the structures of the masticator space, for loco-regional dissemination of malignancies originating in the tonsil, retromolar area, maxillary sinus and nasopharynx to correlate the CT findings with trismus and the tumor dimensions. Material and Methods: The medical records of patients with malignant tumors involving the four regions to be studied were selected from the archives of the Heliopolis Hospital. Patients submited previously to antineoplastic therapy or with local inflammatory or infectious diseases were excluded. The medical records were reviewed by a single examiner, where information was collected on age, gender, tumor location, disease evolution, tumor stage, and the presence or absence of trismus. After administration of iodinated contrast media, the protocol the image acquisition was axial slices 3mm, coronal acquisitions were made when necessary. The image analysis of the MS by two medical examiner residents in their 3rd year of Medical Radiology, at distinct moments , without prior knowledge of the clinical information. In the evaluation of the MS, the findings were transcribed to a specific worksheet, considering the presence or absence of the following items: symmetry with the contralateral MS, obliteration of the fat plane of the retromolar trigone and the pharyngeal space, edema, and/or the atrophy of the medial and lateral pterygoid muscles, and destruction of the mandibular ramus. Results: According to the adopted criteria for trismus in this study, the presence of trismus was observed in 10 patients. The association between tumor size and trismus shows that 90% of patients present size T4, while this percentage is 43% in patients without trismus. Analyzing in terms of odds ratios, the study showed that patients with T4 sized tumors had a chance of developing trismus 11.6 times greater than patients with T0 to T3 sized tumors. The neoplasms of tonsillar crypts and retromolar trigone aggregated 95% of the neoplasms evaluated. Only 5% of the cases accounted for neoplasms of nasopharynx, in which none of them presented the existence of trismus. No cases of neoplasm of maxillary sinus was found. Correlating the CT findings with the group of patients with trismus, the observation was made that 60% of patients with trismus showed edema and/or pterygoid muscle atrophy on CT, whereas this percentage was 21.8% in patients without trismus. Regarding the dimensions of the tumor and its relationship with the image findings, the detection of edema and/or atrophy of the pterygoid muscles was observed only in association with T4 sized tumors. In this instance, patients with edema and/or atrophy of the pterygoid muscles present a 5,4 times greater chance of having trismus. Conclusions: Observed in the following changes in TC IN: obliteration of fat plane in 69.2% of patients, 27.7% asymmetry, edema / atrophy in 26.2% of patients and 20% in bone destruction. The degree of inter examiners were variable. Association was found only among patients with trismus and edema / atrophy of the pterygoid muscles. In this same item was observed association with tumor size T4. We found no association of trismus with other items valued at TC.
298

Tomografia computadorizada por feixe cônico para detecção de lesões incipientes de furca simuladas em mandíbulas suínas maceradas / Cone beam computed tomography for detection of incipient furcation invasion in pig mandibles

Otávio Shoiti Umetsubo 04 July 2011 (has links)
As radiografias intraorais ilustram bem os estágios de reabsorção periodontal nas regiões interproximais. Entretanto, a sobreposição de estruturas dificulta avaliação da perda óssea nas corticais vestibular e lingual. A tomografia computadorizada por feixe cônico (TCFC) é de elevada importância em várias especialidades odontológicas, tais como implantodontia, avaliação de lesões ósseas, estudo da articulação têmporo-mandibular e cirurgia buco-maxilo-facial. A TCFC também tem tido crescente indicação em outras áreas, como a periodontia e endodontia. O objetivo no presente estudo foi a) estabelecer o protocolo de aquisição mais adequado para a detecção de lesões incipientes de furca simuladas quimicamente; e b) avaliar a reprodutibilidade, sensibilidade e especificidade da TCFC, para a finalidade previamente citada. No presente estudo, foram utilizadas 15 mandíbulas suínas maceradas, que apresentavam o segundo molar íntegro e as corticais adjacentes preservadas As simulações de lesões em região de furca foram feitas com aplicação de ácido perclórico a 70%, em até quatro sítios possíveis em cada mandíbula (vestibular do lado direito, lingual do lado direito, vestibular do lado esquerdo, lingual do lado esquerdo) por um examinador participante que não avaliou as imagens. Nos 60 sitios possíveis, foram escolhidos aleatoriamente 20 para as simulações das lesões. Posteriormente, as mandíbulas foram submetidas à TCFC (i-CAT Next Generation) em dois. protocolos de aquição: voxel 0,2 mm e 0,25 mm, ambos com FOV de 6 cm de altura por 16 cm de diâmetro e com 26,9 segundos de tempo. Dois observadores (radiologistas previamente calibrados) avaliaram os exames duas vezes, em ordem aleatória, sob iluminação controlada. Os observadores foram orientados a direcionar a avaliação das regiões dos segundos molares, e questionados se havia lesão ou não nos sítios avaliados. A interpretação das imagens foi realizada em uma estação de trabalho independente localizada no Laboratório de Imagem em Terceira Dimensão da Faculdade de Odontologia da Universidade de São Paulo, utilizando o software Xoran (Xoran Technologies). A sensibilidade, especificidade e reprodutibilidade da TCFC foram avaliadas nos dois protocolos. A TCFC apresentou especificidade alta, sensibilidade baixa e reprodutibilidade moderada na detecção de lesões incipientes de furca. A influência do tamanho do voxel não foi estatisticamente significativa na detecção destas lesões. / Intraoral radiographs illustrate the stages of resorption in periodontal interproximal regions. However, overlapping structures hinders evaluation of bone loss in the buccal and lingual cortical plates. The cone beam computed tomography (CBCT) is of high importance in various dental specialties such as implantology, evaluation of bone lesions, the study of temporomandibular joint and maxillo-facial surgery. The CBCT has also been increasing indications in other areas, such as periodontics and endodontics. The aim of this study was to establish a) the acquisition protocol most suitable for the detection of incipient furcation invasion chemically simulated and b) assess the reproducibility, sensitivity and specificity of CBCT for the purpose previously mentioned. In this study, 15 pigs macerated mandibles were used, which showed the second molar and the adjacent cortical integrity preserved. Simulated lesions in the furcation area were made with application of 70% perchloric acid, up to four possible sites in each jaw (the right buccal, the right lingual, the left buccal, and left lingual side) by an examiner participant who did not evaluate the images. In the 60 possible sites, 20 were randomly chosen for the simulated lesions. Subsequently, the mandibles underwent cone beam computed tomography (Next Generation i-CAT) in two acquisition protocols: at 0.2 mm and 0.25 mm voxel, both with FOV of 6 cm height by 16 cm in diameter and 26.9 seconds of time. Two observers (calibrated radiologists) evaluated the examinations twice, in random order under controlled lighting. Observers were instructed to direct the evaluation to the regions of the second molars, and they were asked if there were or not injuries on those avaluated sites. Image interpretation was performed on an independent workstation located at the Third Dimension Laboratory of Image in the School of Dentistry, University of São Paulo, using the software Xoran (Xoran Technologies). The sensitivity, specificity and reproducibility of CBCT were assessed in both trials. The CBCT showed high specificity, low sensitivity and moderate reproducibility in the detection of incipient lesions, furcation. The influence of voxel size was not statistically significant in detecting these lesions.
299

Desenvolvimento de um Guia orientativo para dosimetria em Tomografia Computadorizada / Development of a guidance guide for dosimetry in computed tomography

Ladyjane Pereira Fontes 19 October 2016 (has links)
Devido as frequentes dúvidas dos usuários das câmaras de ionização do tipo lápis calibradas no Laboratório de Calibração de Instrumentos do IPEN (LCI IPEN), em como aplicar corretamente os fatores indicados em seus certificados de calibração, foi elaborado um guia orientativo para dosimetria em tomografia computadorizada. O guia orientativo inclui o conhecimento prévio da Camada Semirredutora (CSR), já que é necessário conhecer a energia efetiva do feixe para aplicação do fator de correção para qualidade (kq). A avaliação da CSR em tomógrafos torna-se uma difícil tarefa devido à geometria do sistema e por essa razão foi realizado um levantamento das metodologias existentes para a determinação da CSR em feixes clínicos de Tomografia Computadorizada (TC), levando em consideração fatores técnicos, práticos e econômicos. Neste trabalho, optou-se em testar um Sistema Tandem composto por capas absorvedoras confeccionado na oficina do IPEN, baseado em estudos preliminares devido ao baixo custo e boa reposta. O Sistema Tandem é composto por 5 capas absorvedoras cilíndricas de 1 mm, 3 mm, 5 mm, 7 mm, e 10 mm de alumínio e por 3 capas absorvedoras cilíndricas de 15 mm, 25 mm e 35 mm de acrílico (PMMA) acopladas à câmara de ionização do tipo lápis comercial amplamente utilizada em testes de controle de qualidade na dosimetria em feixes clínicos de Tomografia Computadorizada. Através das curvas Tandem, foi possível avaliar os valores de CSR e, através da curva de calibração da câmara de ionização do tipo lápis, encontrar o Kq adequado ao feixe. O Guia elaborado traz informações de como construir a curva de calibração em função da CSR, para encontrar o Kq, bem como informações para construção da curva Tandem, para encontrar valores próximos de CSR. / Due to frequent questions from users of ionization chambers pencil type calibrated in the Instrument Calibration Laboratory of the Institute of Energy and Nuclear Research (LCI - IPEN), on how to properly apply the factors indicated in their calibration certificates, a guide was prepared guidance for dosimetry in computed tomography. The guide includes guidance prior knowledge of half value layer (HVL), as it is necessary to know the effective beam energy for application quality for correction factor (kq). The evaluation of HVL in TC scanners becomes a difficult task due to system geometry and therefore a survey was conducted of existing methodologies for the determination of HVL in clinical beams Computed Tomography, taking into account technical, practical and economic factors. In this work it was decided to test a Tandem System consists of absorbing covers made in the workshop of IPEN, based on preliminary studies due to low cost and good response. The Tandem system consists of five cylindrical absorbing layers of 1mm, 3mm, 5mm, 7mm and 10mm aluminum and 3 cylindrical absorbing covers 15mm, 25mm and acrylic 35mm (PMMA) coupled to the ionization chamber of commercial pencil type widely used in quality control tests in dosimetry in clinical beams Computed tomography. Through Tandem curves it was possible to assess HVL values and from the standard curve pencil-type ionization chamber, Kq find the appropriate beam. The elaborate Guide provides information on how to build the calibration curve on the basis of CSR, to find the Kq and information for construction Tandem curve, to find values close to CSR.
300

Desenvolvimento e caracterização de câmaras de ionização especiais para feixes de tomografia computadorizada / Development and characterization of special ionization chambers for computed tomography beams

Maysa Costa de Castro 02 May 2016 (has links)
O uso de Tomografia Computadorizada (CT) para procedimentos de imagiologia vem crescendo cada vez mais devido aos avanços da tecnologia dos equipamentos de CT, que permitem a obtenção de imagens com melhor resolução do que por outras técnicas, sendo consequentemente responsável pelo aumento da dose de radiação no paciente durante o procedimento. Isso acarretou uma maior preocupação com as doses recebidas pelos pacientes que se submetem a esse tipo de exame. Para a realização da dosimetria de feixes de CT, o instrumento mais utilizado é a câmara de ionização do tipo lápis, pois este dosímetro apresenta uma resposta uniforme ao feixe de radiação incidente em todos os ângulos. A câmara convencional que se encontra disponível no mercado apresenta um comprimento de volume sensível de 10 cm; entretanto, alguns estudos têm mostrado que esse dosímetro tem subestimado os valores de dose. Portanto, neste trabalho optou-se por desenvolver no Laboratório de Calibração de Instrumentos do Instituto de Pesquisas Energéticas e Nucleares (LCI-IPEN/CNEN) duas câmaras de ionização, fazendo uso de materiais nacionais de baixo custo, com comprimentos de volume sensível de 10 cm e 30 cm. A caracterização destas câmaras foi realizada e os resultados se apresentaram dentro dos limites recomendáveis internacionais. Como uma aplicação, as câmaras desenvolvidas, juntamente com uma câmara comercial, foram testadas em um tomógrafo clínico. As câmaras de ionização desenvolvidas foram analisadas de maneira completa, para os seus possíveis usos. / The use of computed tomography (CT) for imaging procedures is growing due to advances in the CT equipment technology, because they allow the obtention of images with better resolution than through other techniques. Therefore, they are responsible for increasing the dose radiation of patients during the procedure. This fact led to a greater concern about the doses received by patients who undergo this type of examination. To perform the dosimetry in CT beams, the most widely used instrument is the pencil type ionization chamber, because this dosimeter has a uniform response to the incident radiation beam for all angles. The conventional ionization chamber, which is available on the market, has a sensitive volume length of 10 cm; however, some studies have shown that this dosimeter has underestimated the dose values. Therefore, in this study two ionization chambers with sensitive volume lengths of 10 cm and 30 cm, making use of low cost national materials, were developed at the Calibration Laboratory of Instruments (LCI-IPEN/CNEN). The characterization of these chambers was performed, and the results were obtained within the international recommended limits. As an application, the developed ionization chambers and a commercial chamber were tested in a clinical tomographer. The developed ionization chambers were analyzed in a complete way for their possible uses.

Page generated in 0.0765 seconds