• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 55
  • 13
  • 4
  • 3
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 118
  • 118
  • 53
  • 45
  • 28
  • 18
  • 17
  • 17
  • 14
  • 14
  • 12
  • 11
  • 11
  • 11
  • 10
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Estabelecimento de um novo metodo de calibracao de camaras de ionizacao tipo lapis para dosimetria em feixes de tomografia computadorizada / Establishment of a new calibration method of pencil ionization chamber for dosimetry in computed tomography

DIAS, DANIEL M. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:28:45Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:57:14Z (GMT). No. of bitstreams: 0 / As câmaras de ionização tipo lápis são utilizadas para dosimetria de feixes em equipamentos de tomografia computadorizada (CT). Neste estudo foi estabelecida uma nova metodologia de calibração destas câmaras, visando a adequação do Laboratório de Calibração de Instrumentos do Instituto de Pesquisas Energéticas e Nucleares (LCI) aos atuais padrões metrológicos internacionais que tratam dos procedimentos específicos para calibração das câmaras utilizadas em CT. Primeiramente partiu-se da implantação das novas qualidades de radiação padrão RQT, que simulam feixes não atenuados usados para aplicações em CT, de acordo com a IEC 61267 da International Electrotechnical Commission (IEC). Após o estabelecimento dos campos padrões de radiação, foi implantada a metodologia de calibração específica para câmaras lápis segundo o Technical Report Series No. 457, da International Atomic Energy Agency (IAEA), que descreve as particularidades do procedimento a ser seguido pelos Laboratórios de Dosimetria Padrão Secundário (SSDLs) em termos de colimação e posicionamento em relação ao feixe de radiação. Inicialmente, foram realizadas medições de PPV (kV) e determinação das filtrações adicionais de cobre por meio dos valores de camada semi-redutora (CSR) recomendados pela norma IEC 61267, para que as qualidades de radiação de referência: RQT 8, RQT 9 e RQT 10 fossem implantadas. Para os filtros adicionais, foram utilizados alumínio e cobre de alta pureza (maior ou igual a 99,9%). Uma metodologia alternativa para determinar as filtrações adicionais também foi utilizada, através da qual se encontrou diretamente as RQTs em espessuras de filtros de cobre equivalente ao conjunto RQR (Al) + Filtração Adicional (Cu), sendo esta uma opção quando não se têm implantadas as RQRs. Com a implantação desta nova metodologia de calibração das câmaras de ionização tipo lápis, o LCI está pronto para calibrar estes instrumentos de acordo com as recentes recomendações internacionais. Permitindo assim uma melhoria na rastreabilidade das calibrações, como também na qualidade dos serviços metrológicos que o IPEN oferece para todo o País. / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
22

Desenvolvimento de um sistema de tomografia por coerencia optica no dominio de Fourier sensivel a polarizacao e sua utilizacao na determinacao das matrizes de mueller / Development of an polarization sensitive Fourier domain optical coherence tomography and it utilization on the Mueller matrix determination

RAELE, MARCUS P. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:26:57Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:58:18Z (GMT). No. of bitstreams: 0 / Este estudo abordou os aspectos teóricos e experimentais relacionados ao desenvolvimento de um sistema de tomografia por coerência óptica (OCT) no domínio de Fourier sensível à polarização (PS-FD-OCT) e a sua utilização na determinação da Matriz de Mueller (MM-OCT). O estudo iniciou-se com uma revisão bibliográfica que abordou desde os primeiros estudos relacionados à técnica até o estado da arte, bem como o formalismo matemático da interferometria de baixa coerência no domínio espectral e polarização da luz. Realizaram-se estudos baseados em simulação numérica sobre três tipos diferentes de algoritmos, responsáveis pela recuperação do sinal de espalhamento, sendo eles: a Transformada de Fourier Direta; Interpolação e Zero-Filling. Ao fim dessa etapa concluiu-se que o algoritmo Zero-Filling 2N apresentou melhores características quando comparado aos outros algoritmos. Na parte experimental, primeiramente, diferentes arranjos OCT foram montados e medidas realizadas para verificação aspectos relacionados à teoria. Consecutivamente, utilizando uma amostra polimérica, realizaram-se imagens de birrefringência, que permitiram a determinação da birrefringência da amostra quantitativamente. Finalmente, imagens em diferentes estados de polarização foram realizadas, através delas determinou-se as imagens referentes aos elementos das Matrizes de Mueller, que foram analisadas individualmente. / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
23

Efeitos do colimador na qualidade de imagem em tomografia industrial de terceira geração / Collimator effects on image quality in industrial tomography third generation

CARVALHO, DIEGO V. de S. 10 November 2014 (has links)
Submitted by Claudinei Pracidelli (cpracide@ipen.br) on 2014-11-10T11:06:37Z No. of bitstreams: 0 / Made available in DSpace on 2014-11-10T11:06:37Z (GMT). No. of bitstreams: 0 / O estudo do efeito da colimação nos detectores de radiação sobre a qualidade de imagem do tomógrafo industrial de terceira geração desenvolvido no IPEN/CNEN-SP é descrito neste trabalho. Três conjuntos de colimadores de chumbo foram projetados e confeccionados, sendo um com janelas retangulares de 2 x 5 x 50 mm e outro com 4 x 10 x 50 mm (largura x comprimento x profundidade) e um terceiro com orifício circular de 5 mm de diâmetro x 40 mm de profundidade. Os colimadores foram projetados para poderem ser facilmente substituídos entre si nos detectores de radiação. Paralelamente, foram confeccionados e utilizadas a eletrônica associada, constituída de analisadores de sinais tipo multicanal de 8 bits contendo a unidade de alta tensão e o amplificador. Dentre as vantagens deste sistema destaca-se a sua capacidade de análise multicanal rápida e possuir uma eletrônica mais simples. Valores de resolução energética comparável com a da literatura foram encontrados utilizando a eletrônica desenvolvida acoplada ao detector de radiação de NaI(Tl). Os efeitos dos colimadores foram avaliados pelas medidas tomográficas em um fantom de polimetilmetacrilato contendo componentes multifásicos estáticos (ferro, alumínio e ar). Fontes de radiação com energias de das fontes de 75Se (97 keV, 121 keV, 136 keV, 265 keV, 279 keV e 400 keV), de 137Cs (662 keV) e de 192Ir (317 keV, 468 keV e 602 keV) observou-se que a melhor imagem do fantom foi obtida com os colimadores de janelas retangulares (fendas) de 2 x 5 x 50 mm. Na avaliação dinâmica da formação de bolhas em coluna simuladora de processos industriais, a melhor imagem foi obtida com a fonte de 192Ir. / Dissertação (Mestrado em Tecnologia Nuclear) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
24

Teoria e experimentação com metodos incrementais relaxados em tomografia por emissão / Theory and experimentation with relaxed incremental methods in emission tomography

Helou Neto, Elias Salomão 04 December 2005 (has links)
Orientador: Alvaro Rodolfo De Pierro / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Matematica, Estatistica e Computação Cientifica / Made available in DSpace on 2018-08-14T01:15:10Z (GMT). No. of bitstreams: 1 HelouNeto_EliasSalomao_M.pdf: 1733678 bytes, checksum: 44e680915a74638897d279b1d09a007f (MD5) Previous issue date: 2005 / Resumo: O principal assunto desta dissertação é a teoria e prratica em metodos iterativos incrementais relaxados para reconstrução estatística de imagens em Tomografia por Emissão de Positrons - PET. Especial atenção é dedicada ao estudo teorico dos algoritmos, com a apresentação de resultados novos sobre convergência com o parâmetro de relaxação variando dentre as subiterações e sobre a regularidade da sequência gerada por tais algoritmos no caso específico da função de log-verossimilhança que surge em PET. Alem disso, uma comparação experimental entre a qualidade da imagem obtida com metodos relaxados e não relaxados é efetuada / Abstract: The main subject of this dissertation is the theory and practice in iterative incremental relaxed methods for statistical image reconstruction in Positron Emission Tomograpy | PET. Special atention is drawn to the theoretical study of the algorithms, with the presentation of new results concerning convergence with a relaxation parameter wich is allowed to vary within the subiterations and about the regularity of the sequence generated by such algorithms in the specific case of the log-likelihood function that arises in PET. Furthermore, an experimental comparsion is made to test the quality of the image obtained with relaxed methods against those generated by non-relaxed ones / Mestrado / Mestre em Matemática Aplicada
25

Influencia dos fatores de obtenção das imagens de tomografia computadorizada na acuracia de modelos produzidos por prototipagem rapida / Influence of the acquisition factors of computerized tomography images on the accuracy of models produced by rapid prototyping

Guedes, Fabio Ribeiro 02 February 2007 (has links)
Orientador: Glaucia Maria Bovi Ambrosano / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-08T02:02:34Z (GMT). No. of bitstreams: 1 Guedes_FabioRibeiro_D.pdf: 610319 bytes, checksum: 9bcc253688efef523d092d4350e7889f (MD5) Previous issue date: 2007 / Resumo: Esta pesquisa teve o objetivo de avaliar a influência dos fatores de obtenção das imagens de tomografia computadorizada na acurácia de modelos produzidos por meio de prototipagem rápida, verificando o grau de distorção dos protótipos produzidos a partir de imagens de tomografia computadorizada. Para isto foram selecionados 10 ramos mandibulares humanos macerados, os quais foram submetidos a exames de tomografia computadorizada. Para a obtenção das imagens dos cortes axiais, diferentes seqüências de escaneamento foram obtidas, variando o diâmetro do FOV (Field of View) em 200 mm, 250 mm e 300 mm; a espessura de corte em 0,5 mm; 1,0 mm e 1,5 mm; e o algoritmo de imagem, sendo selecionado o algoritmo para tecido ósseo, cerebral e base de crânio e órbita. Todas as seqüências de imagens obtidas foram gravadas na linguagem DICOM em CD-ROM e enviadas ao Centro de Pesquisas Renato Archer (CenPRA) para confecção dos modelos. Foi realizada a segmentação das imagens de cada um dos fatores, efetuando as reconstruções tridimensionais (3D) dos ramos de mandíbula, ajuste dos fatores da imagem e conversão para o formato STL. Os arquivos em STL foram enviados aos equipamentos para produção dos protótipos por dois processos: a Sinterização Seletiva a Laser (SLS) e a Impressão Tridimensional (3DP). Após a confecção dos modelos, foram realizadas mensurações em oito regiões de todos os modelos, e as mesmas medidas foram realizadas nos segmentos ósseos que deram origem aos modelos obtendo-se os valores reais. Os valores obtidos para cada uma das regiões dos modelos foram comparados estatisticamente com os valores reais; sendo calculado o percentual de erro dos modelos produzidos com cada um dos fatores estudados e comparado-os entre si, utilizando a Análise de Variância além da acurácia das técnicas de prototipagem 3DP e SLS. Foi verificado que em sete das oito regiões selecionadas, os valores diferiram estatisticamente (p<0,05) do valor real para todos os fatores de imagem. Observou-se que para os protótipos produzidos com a espessura de corte de 0,5 mm; 1,0 mm e 1,5 mm o percentual de erro foi de 8,97%, 10,70% e 11,49% respectivamente havendo diferença estatística entre o grupo 0,5 mm e os demais. Para os modelos obtidos com o diâmetro do FOV de 200 mm, 250 mm e 300 mm, o percentual de erro foi de 8,97%, 10,63% e 11,02% respectivamente havendo diferença estatística entre o grupo 200 mm e os demais, porém para os modelos produzidos a partir dos diferentes tipos de algoritmos de imagem, o percentual de erro obtido foi de 8,97% para tecido ósseo, 9,76% para tecido cerebral e 9,85% para base de crânio e órbita, não havendo diferença estatística entre eles (p>0,05). Foi observado ainda que os protótipos produzidos por 3DP e SLS apresentaram diferenças médias quando comparados com o real de 1,58 mm e 1,19 mm, respectivamente. Com base nos resultados obtidos, pode-se concluir que para a obtenção de protótipos com dimensões mais próximas do real deve-se utilizar uma menor espessura de corte e um menor diâmetro do FOV, enquanto que o algoritmo das imagens não influencia na acurácia dos protótipos, devendo-se os mesmos serem produzidos pelo método de sinterização seletiva a laser / Abstract: The aim of this study was to evaluate the influence of the factors of attainment of the computerized tomography images in the accuracy of models produced by means of rapid prototyping, verifying the distortion degree of the prototypes produced from images of tomography computerized. Ten dry human mandibles branches had been selected, which had been submitted to the computerized tomography scan. For the attainment of the axial images, different sequences of scanning had been gotten, varying the diameter of the FOV (Field of View) in 200 mm, 250 mm and 300 mm; the slice thickness in 0,5 mm; 1,0 mm and 1,5 mm; e the algorithm of image, being selected bone, cerebral the algorithm for base of skull and orbit. All the sequences of gotten images had been recorded in DICOM language in a CD-ROM and sent to the Renato Archer Research Center (CenPRA) for production of the models. The segmentation of the images of each one of the studied factors was carried through, and the three-dimensional reconstructions (3D) of the jaw branches, adjustment of the factors of the image and conversion to the STL format were made. The files in STL format had been sent to the equipment for production of the prototypes by two processes: the Selective Laser Sintering (SLS) and the Threedimensional Printer (3DP). After the confection of the models, eight regions had been measured of all models produced, and the same measures had been carried through in the bone segments that had given to origin to the models getting the real values. The values gotten for each one of the regions of the models had been compared statistically with the real values; being calculated the percentage of error of the models with each one of the studied factors and compared among themselves, using the Analysis of Variance beyond the accuracy of the 3DP and SLS techniques. It was verified that in seven of the eight selected regions, the values had differed statistically (p<0,05) from the real value for all the image factors. It was observed that for the models produced with the slice thickness of 0,5 mm; 1,0 mm and 1,5 mm the percentage of error were of 8,97%, 10.70% and 11.49% respectively showing statistical differences between group 0,5 mm and other. For the models produced with the diameter of FOV of 200 mm, 250 mm and 300 mm, the percentage of error was of 8,97%, 10.63% and 11.02% respectively showing statistical differences between group 200 mm and other, however for the models produced from the different types of image algorithm, the percentage of gotten error was of 8,97% for bone, 9.76% for cerebral and 9.85% for skull base and orbit, not showing statistical differences between them (p>0,05). It was still observed that the models produced by 3DP and SLS had presented an average differences comparing to the real values of 1,58 mm and 1,19 mm, respectively. Based on the gotten results, can be concluded that for the attainment of prototypes with dimensions next to the real, it must be used a lesser slice thickness and a lesser diameter of the FOV, whereas the algorithm of the images does not influence in the accuracy of the prototypes, and to be produced by the selective laser sintering method / Doutorado / Radiologia Odontologica / Doutor em Radiologia Odontológica
26

Day-of-Injury Computed Tomography (CT) and Longitudinal Rehabilitation Outcomes: A Comparison of the Marshall and Rotterdam CT Scoring Methods

Alder, Kayla Michelle 01 April 2018 (has links)
Both individual patient-related and injury-related factors predict functional outcomes following moderate-to-severe traumatic brain injury (M/S TBI). Other than binary outcomes such as death, little is known about the role of day-of-injury neuroimaging in predicting long- term outcomes. Classification systems for assessing the severity of injury using computerized tomography (CT) scans, such as the Marshall Classification System (MCS) or Rotterdam scale, have not been systematically studied to see how they relate to long-term rehabilitation and functional outcomes following M/S TBI. The MCS consists of six categories based on information about midline shift, basal cistern compression, surgery evacuation, and lesion size. The Rotterdam scale, however, is a summed score ranging from 1-6 based on the extent of basal cistern compression, extent of midline shift, presence/absence of an epidural lesion, and presence/absence of traumatic subarachnoid hemorrhage (tSAH) or intraventricular blood. The differences between these two CT scales suggest the possibility that MCS and Rotterdam scales may differ in their ability to predict subsequent rehabilitation outcomes. Thus, we compared the relative predictive value of MCS and Rotterdam scores on long-term rehabilitation functional outcomes using the Functional Independence Measure (FIM) at rehabilitation discharge and nine-month post-discharge follow up. The study included 88 participants (25 females, mean age: 42.0 [SD: 21.3]) with M/S TBI. Day-of-injury CT images were scored using both MCS and Rotterdam criteria. Functional outcomes were measured by the cognitive and motor subscales on the FIM at discharge and after nine-month follow up, and length of stay in rehabilitation. Data were analyzed using multiple linear regression models. Neither MCS nor Rotterdam scores nor rehabilitation length of stay significantly predicted motor or cognitive outcomes at discharge or nine-month follow-up. MCS and Rotterdam scales may have limited utility in predicting long- term functional outcome in a rehabilitation setting, but instead appear to be good predictors of acute outcomes, especially regarding mortality and elevated intracranial pressure (ICP). Future research could focus on CT characteristics such as midline shift to predict long-term rehabilitation outcomes to guide treatment instead of CT rating scales.
27

Network approach to impedance computerized tomography

Dai, Hong January 1985 (has links)
No description available.
28

ACCURACY OF CONE-BEAM COMPUTERIZED TOMOGRAPHY IN DETERMINING THE THICKNESS OF THE PALATAL MASTICATORY MUCOSA

Hardison, Justin 23 April 2012 (has links)
BACKGROUND: The aim was to compare the thickness of the palatal masticatory mucosa as determined on a cone-beam computerized (CBCT) scan versus thickness determined via bone-sounding. METHODS: A total of twenty patients requiring palatal surgery participated. Thickness of the palatal tissue was measured at various points radiographically and clinically. The two techniques were compared to determine the agreement of the two measurement modalities. RESULTS: Analysis of variance determined that there was no significant difference between the two methods. A small bias of the radiographic measurement being larger was found to be statistically significant (0.09 ± 0.69mm; p <0.0001). Moreover, the tissue thickness was shown to increase as the distance from the gingival margin increased and the tissue over the molars was thinner than the tissue over the premolars. CONCLUSIONS: CBCT can be used to accurately determine the soft tissue thickness of the palatal masticatory mucosa with minimal bias.
29

Estudo da prevalência da posição vestíbulo-lingual do canal mandibular por meio da tomografia computadorizada helicoidal / Prevalency study of the vestibulo-lingual position from the mandibular canal by helical computerized tomography

Coppedé, Cláudio Tizzani 23 September 2008 (has links)
O trajeto do canal da mandíbula é oblíquo com sentido póstero-anterior, apresenta-se próximo da cortical óssea alveolar medial, até atingir a face mesial do primeiro molar inferior, a partir desta região aproxima-se da lâmina óssea alveolar lateral até alcançar o forame mentual. Radiograficamente, o canal da mandíbula se apresenta, como uma linha radiolúcida delimitada por duas linhas radiopacas. Existem diversos métodos de exames radiográficos que possibilitem a avaliação do complexo maxilo-mandibular. Estudos mostram que a Tomografia Computadorizada (TC) foi considerado o melhor método para a avaliação do trajeto no sentido vestíbulo-lingual do canal da mandíbula. Foi proposto analisar a morfologia no sentido vestíbulo-lingual das variações do trajeto do canal da mandíbula em imagens de TC utilizando o software Dental Slice®. Com a ferramenta mensuração deste software , avaliou-se 100 TC bilateralmente, criando-se três retas. Uma horizontal (vestíbulo-lingual), dividindo o canal ao meio, e duas retas verticais, tangenciando a face externa lingual e vestibular da cortical do canal. Para análise dos dados utilizou os testes de normalidade, teste de hipótese (teste t e ANOVA) e teste de aderência Anderson Darling. Concluiu-se que existe uma tendência da presença de pouca variabilidade, entre os lados direito e esquerdo; a porção do canal mais próxima ao forame mentual apresenta-se vestibularizado, e na região posterior lingualizado; há necessidade da avaliação topográfica do canal da mandíbula por meio da Tomografia Computadorizada. / The course of the mandibles canal is oblique with posterior-anterior direction, it comes close to the medial cortical alveolar bony, until reaching the mesial face of the first inferior molar, starting from this area, it approaches of the lateral cortical alveolar bony until reaching the forame mentual. Radiographically, the manbible´s canal comes, as a radiolucent line defined by two radiopaque lines. Several methods of exams radiographyc that facilitate the evaluation of the complex maxilo-mandibular. Studies show that the Computerized Tomography (TC) is the best method for consider the evaluation of the course in the vestibule-lingual direction of the mandibles canal. It was intended to analyze the morphology in the vestibule-lingual direction of the variations of the course the mandibles canal in images of TC using the Dental Slice® software. With the mensuration tool of this software, 100 TC was evaluated bilaterally, being created three straight line. A horizontal one (vestibule-lingual), dividing the canal in the middle, and two vertical straight line, being tangent to the lingual external face and vestibular of the canals cortical. For analysis of the data it used the normality tests, hypothesis test (tests t and ANOVA) and test of adherence Anderson Darling. It conclude that a tendency exists the presence of little variability, among the sides right and left. The canal close to the forame mentual presents vestibular direction, and in the posterior area on lingual direction. And Confirm the need of the use of TC in the topographical evaluation of the mandibles canal.
30

Reconstrução tridimensional de objetos a partir das projeções de suas secções / Tridimensional objects reconstruction from the projections of theirs sections

Mattos, Patrícia Noll de January 1996 (has links)
Este trabalho trata da reconstrução tomográfica bidimensional e tridimensional, a partir de projeções, visando sua utilização em qualquer aplicação que necessite do volume completo do objeto em questão ou que necessite das imagens adquiridas dos- objetos projetados. Propicie-se utilizar um dos métodos pelo qual a tomografia Computadorizada gera as fatias bidimensionais do corpo exposto, expandindo-o para a terceira dimensão. Para tornar isto possível, é necessário o estudo de métodos de reconstrução-bidimensional, bem como a implementação de um deles. E desenvolvido, então, um estudo sobre os conceitos da tomografia computadorizada, seus diferentes tipos, contendo, os métodos de reconstruçãobidimensional utilizado por elas, alem, dos métodos de aquisição das projeções dos objetos a serem reconstruídos. E apresentada uma proposta de trabalho bidimensional, onde será implementado, alem do algoritmo de reconstrução, o processo de aquisição das projeções do objeto em questão, bem como, a modelagem do mesmo. Além, do desenvolvimento de uma proposta de trabalho tridimensional, onde o método de reconstrução bidimensional desenvolvido será expandido para a terceira dimensão e implementado, juntamente com o processo de aquisição dos objetos tridimensionais projetados, bem como, a modelagem dos mesmos. Um protótipo para cada uma destas propostas é gerado, contendo, cada um, a etapa de aquisição das imagens projetadas, e a etapa de reconstrução do objeto. Tanto os resultados da imagem sendo reconstruída, como as imagens adquiridas dos objetos projetados, são Bravados em arquivos. Por fim, é apresentada uma analise dos resultados gerados por estes protótipos, no que diz respeito a convergência de seus algoritmos, e a melhor maneira de utilizá-los, a fim de se obter um melhor resultado. / This paper is about bidimensional and tridimensional tomographic reconstruction working with projections in order to use in any application that needs complete volume of the object used or that needs images of the projected objects acquired. It is used one of the methods by which the computerized tomography generates bidimensional slices of the exposed body expanding it to third dimension. In order to make it possible it was necessary to study bidimensional reconstruction methods, as well as implementing one of them. It is developed a study on concepts of computerized tomography, its different types, including bidimensional reconstruction methods used by them, besides the methods used to acquire projections of the objects to be reconstructed. It is presented a proposal of the bidimensional work, where it will be implemented, besides the reconstruction algorithm, the aquisition process of the projection of the meant objects, as well as modelling them. It is also developed a proposal of a tridimensional work, where the bidimensional reconstruction method developed will be implemented and expanded to third dimension as well as the process of aquisition of the tridimensionals projected objects as well as modelling them. A prototype of these proposals is generated , containing each one the aquisition step of the projected images and the reconstruction step of the object. The results of the reconstructed image as well as the acquired images of the projected objects are saved in files. Finally it is presented an analysis of the generated results of the prototypes as to the convergence of these algorithms and the best way to use them in order to obtain a better result.

Page generated in 0.0826 seconds