• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 177
  • 3
  • 2
  • Tagged with
  • 183
  • 183
  • 127
  • 123
  • 101
  • 76
  • 38
  • 36
  • 35
  • 26
  • 25
  • 23
  • 20
  • 20
  • 19
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
101

Estudo da distribuição dimensional de poros e da condutividade hidráulica de solos arenosos compactados tratados com cal e cimento / Study of the pore dimensional distribution and hydraulic conductivity of sandy compacted soils treated with lime and cement

Ibeiro, Lidiane da Silva January 2016 (has links)
A técnica de estabilização de solos através da incorporação de agentes cimentantes é uma opção eficaz e amplamente utilizada em obras de engenharia geotécnica. Portanto, são relevantes os estudos que contemplam aspectos ainda não bem compreendidos relativos aos efeitos causados pela adição de agentes cimentantes na porosidade dos materiais obtidos e, por consequência, nas propriedades de desempenho destas misturas. Neste sentido, o presente trabalho pretende contribuir no que tange ao conhecimento da estrutura de poros de solos compactados tratados com cal e cimento e sua relação com o comportamento hidráulico destes materiais. Os solos utilizados têm granulometria arenosa e areno-siltosa. As variáveis de controle envolvidas nas análises são os teores dos agentes de cimentação empregados (cal e cimento), densidades de compactação e tempos de cura (para amostras com cal). Para a caracterização dos sistemas de poros empregou-se porosimetria por intrusão de Mercúrio e, de forma complementar, na quantificação das porosidades globais, microtomografia computadorizada de raios x. Um permeâmetro de parede flexível foi utilizado para as determinações das condutividades hidráulicas das amostras estudadas através de ensaios de carga constante. Para as amostras de matriz arenosa pura, os volumes de intrusão indicaram maior refinamento da rede porosa, sob efeito da cimentação, para as condições mais densas de moldagem. Para as amostras de matriz areno-siltosa, ao se variarem as condições de cimentação, e fixando-se o peso específico aparente seco, os volumes intrudidos indicaram o refinamento dos poros quando da adição de cal ou cimento em comparação à condição não cimentada. Com respeito à análise da influência do tempo de cura para as amostras moldadas com cal, os resultados sugeriram que a adição de cal (aos 7 dias de cura) não causou variação da porosidade, comparada à condição sem cimentação, mas aos 28 dias foi possível perceber o aumento da porosidade global e, com o passar do tempo (180 dias) verificou-se a redução da porosidade. O refinamento dos poros se tornou cada vez mais pronunciado conforme a evolução do tempo. Para a matriz arenosa, foi identificado que a adição de cimento e a variação da porosidade de moldagem não implicaram em mudanças mensuráveis no valor da condutividade hidráulica, quando comparadas às condições com e sem cimento. Para as amostras da matriz areno-siltosa, sob diferentes condições analisadas (adição de cal aos diferentes tempos investigados e adição de cimento), foi evidenciado que o peso específico aparente seco de moldagem causou influência significativa sobre a condutividade hidráulica. Foram obtidos bons ajustes para as correlações condutividade hidráulica versus relação porosidade/teor volumétrico do agente cimentante ao se aplicar a potência de 0,032 sobre o parâmetro teor volumétrico do agente cimentante. As curvas obtidas apresentaram relações distintas e sinalizaram aspectos do comportamento do material: aumento da condutividade hidráulica para 28 dias de cura da cal, em relação a 7 dias; para 180 dias e amostras nas condições menos densas, não ocorreu modificação em relação à idade de 28 dias, mas na condição mais densa o parâmetro investigado tornou-se sensível às modificações promovidas por efeitos do tempo de cura; ainda, para as amostras moldadas com cimento, ocorreu redução mais pronunciada da condutividade hidráulica relacionada às condições mais densas de moldagem. / The soil stabilization technique which incorporates cementing agents is an effective alternative and widely used in geotechnical engineering works. Therefore, research on the aspects not well understood related to the effects caused by the addition of cementing agents on the porosity of the obtained materials and, consequently, on the performance properties of cemented blends, are relevant. In this sense, this study aims to contribute improving the knowledge on the pore structure of compacted soils treated with lime and cement, as well as to the relationship between pore structure and the hydraulic behavior of these materials. The used soils have a sandy and sandy-silty grain size distribution. The studied variables involved in the analysis are: the cement and lime contents; compaction density; and curing time (for samples with lime). To characterize the pore systems it was employed the Mercury intrusion porosimetry test and, additionally, in order to quantify the global porosities, it was used x-ray computed microtomography tests. A flexible wall permeameter was used to determinate the hydraulic conductivity of the samples through constant head tests. For sandy samples, the intrusion volumes indicated a more significant reduction of the porous media, under the effect of the cementation, when compacted in denser conditions. For the sandy-silt samples, it was observed that by maintaining the specific dry unit weight constant and by varying the cementation conditions, the intruded volumes indicated a reduction of the pores after the addition of lime or cement compared to the uncemented samples. With regards to the influence of the curing time for samples treated with lime, the results suggested that the addition of lime after 7 days of curing did not cause variation in porosity, compared to condition without cementing additions; however, after 28 days of curing it was observed a slight increase on the overall porosity and, after 180 days of curing, it was observed a reduction of the porosity. The reduction of the pores became more significant with the curing time. Related to the sandy soil, the results indicated that addition of cement to the soil and variations on the molding porosity did not result in measurable changes in the hydraulic conductivity, when compared the conditions with and without cement. For the sandy-silt samples, which were analyzed under different conditions (addition of lime and different curing times, and addition of cement), it was shown that the specific dry unit weight caused significant influence on the hydraulic conductivity. It was observed a satisfactory correlation between hydraulic conductivity and porosity/cementing agent ratio when the volumetric cementing agent content is to the power of 0,032. The obtained curves showed distinct relationships and indicated the following aspects of the material behaviour: the increasing of the hydraulic conductivity after 28 days of curing of the sample with lime, compared to 7 days of curing; after 180 days of curing and under low compaction conditions, it was observed no changes when compared to the samples tested after 28 days of curing; however, in the densest condition the investigated parameter became dependent on the curing time; moreover, for the samples molded with cement, it was observed a more significant reduction of the hydraulic conductivity related to denser molded conditions.
102

Simulação do movimento da água no solo utilizando modelo numérico

Biassusi, Marcelo January 2001 (has links)
Um dos principais desafios para o século XXI é o uso sustentável dos recursos hídricos. A agricultura é a maior usuária desse recurso, sendo responsável por aproximadamente 70% dos gastos globais de água. Para o uso racional da água é necessário o conhecimento das propriedades hidráulicas do solo na condição de não-saturação. A simulação do movimento da água no solo através da modelagem é uma ferramenta importante no entendimento do sistema solo-água-planta, pois permite a previsão e estudo do comportamento da redistribuição da água no solo de maneira eficiente. Porém a forte dependência entre os parâmetros hidráulicos do solo (teor de água, potencial matricial e condutividade hidráulica) fazem da modelagem um assunto complicado, necessitando de modelos numéricos que utilizem intervalos discretos de tempo e espaço. Esses intervalos devem ser suficientemente pequenos para que dentro de um intervalo as variações dos parâmetros hidráulicos sejam insignificantes. Nesta tese é proposto um algoritmo para a descrição do movimento vertical da água no solo, definindo o intervalo de tempo como função de uma variação máxima admissível do teor de água. O algoritmo foi testado para alguns conjuntos de dados hidráulicos de solos, utilizando as condições de contorno de um experimento de perfil instantâneo. A eficiência do algoritmo foi verificada em situações práticas, como na previsão do teor de água na Capacidade de Campo e na predição do tempo para ser atingida determinada condição de umidade no solo. Utilizando o algoritmo, também foram estudados o comportamento da retenção e dos parâmetros de condutividade em relação aos parâmetros de drenagem. Concluiu-se que o algoritmo descreve adequadamente o processo de redistribuição de água no solo utilizando intervalos suficientemente pequenos de tempo e espaço; a forma de discretização do tempo não comprometeu a acurácia das medidas; a previsão do teor de água na Capacidade de Campo e do tempo para ser atingida determinada condição de umidade no solo foram satisfatórias; e o algoritmo permite o estudo das relações entre os parâmetros hidráulicos do solo.
103

Simulação do movimento da água no solo utilizando modelo numérico

Biassusi, Marcelo January 2001 (has links)
Um dos principais desafios para o século XXI é o uso sustentável dos recursos hídricos. A agricultura é a maior usuária desse recurso, sendo responsável por aproximadamente 70% dos gastos globais de água. Para o uso racional da água é necessário o conhecimento das propriedades hidráulicas do solo na condição de não-saturação. A simulação do movimento da água no solo através da modelagem é uma ferramenta importante no entendimento do sistema solo-água-planta, pois permite a previsão e estudo do comportamento da redistribuição da água no solo de maneira eficiente. Porém a forte dependência entre os parâmetros hidráulicos do solo (teor de água, potencial matricial e condutividade hidráulica) fazem da modelagem um assunto complicado, necessitando de modelos numéricos que utilizem intervalos discretos de tempo e espaço. Esses intervalos devem ser suficientemente pequenos para que dentro de um intervalo as variações dos parâmetros hidráulicos sejam insignificantes. Nesta tese é proposto um algoritmo para a descrição do movimento vertical da água no solo, definindo o intervalo de tempo como função de uma variação máxima admissível do teor de água. O algoritmo foi testado para alguns conjuntos de dados hidráulicos de solos, utilizando as condições de contorno de um experimento de perfil instantâneo. A eficiência do algoritmo foi verificada em situações práticas, como na previsão do teor de água na Capacidade de Campo e na predição do tempo para ser atingida determinada condição de umidade no solo. Utilizando o algoritmo, também foram estudados o comportamento da retenção e dos parâmetros de condutividade em relação aos parâmetros de drenagem. Concluiu-se que o algoritmo descreve adequadamente o processo de redistribuição de água no solo utilizando intervalos suficientemente pequenos de tempo e espaço; a forma de discretização do tempo não comprometeu a acurácia das medidas; a previsão do teor de água na Capacidade de Campo e do tempo para ser atingida determinada condição de umidade no solo foram satisfatórias; e o algoritmo permite o estudo das relações entre os parâmetros hidráulicos do solo.
104

Soluções analíticas para transporte de hidrocarbonetos do petróleo em água subterrânea : avaliação determinística e probabilística do risco à saúde humana

Melo, Tirzah Moreira de January 2010 (has links)
O presente trabalho apresenta um estudo de caso de contaminação de solo e água subterrânea por derivados do petróleo em uma refinaria da região Sudeste do país, para o qual foram aplicados todos os níveis ou tiers da metodologia RBCA de avaliação de risco à saúde humana. Diferentes vias de exposição foram consideradas ao longo de toda a metodologia, a qual foi dividida em determinística, compreendendo os dois primeiros níveis, e estocástica, no caso do terceiro nível. Sobre a abordagem determinística, o modelo de Domenico (1987) para transporte de contaminantes em água subterrânea foi substituído por um conjunto de soluções analíticas que considera diferentes geometrias de fonte de contaminação para casos instantâneos e contínuos de liberação de contaminantes, permitindo que a metodologia RBCA também possa ser empregada mesmo quando o modelo de Domenico (1987) não se aplica. A comparação deste conjunto de soluções com outro utilizado apenas para comparar e confirmar a validade dos modelos escolhidos demonstrou grande estabilidade nas soluções, enquanto os modelos de comparação apresentaram instabilidade nas soluções para altos valores da variável tempo. Tal fato comprovou a viabilidade do emprego do conjunto de soluções analíticas proposto para avaliação de risco à saúde humana. No contexto da abordagem estocástica da estimativa do risco, o método de Monte Carlo foi empregado para propagação das incertezas sobre uma das soluções analíticas citadas anteriormente, da qual, por sua vez, foram extraídos os resultados para a simulação estocástica do risco para a via de contato dermal com água superficial contaminada por Benzeno. Os resultados da simulação estocástica demonstraram uma correlação muito grande do risco com a variável C (concentração do contaminante), a qual, por sua vez, foi modelada pela simulação estocástica da condutividade hidráulica. Logo, pode-se concluir que a condutividade hidráulica afeta a estimativa do risco, para o qual observou-se uma diferença de seis ordens de magnitude entre o valor mínimo e o máximo simulados e duas ordens de magnitude para o valor real do risco. / This dissertation presents a case study on soil and ground water contamination by components derived from petroleum in a refinery located in the Southeast region of Brazil. All of the RBCA health risk assessment methodology tiers were applied in this study. Different exposure pathways were considered throughout the methodology. Firstly, the deterministic approach which encompasses the first two tiers and secondly, the stochastic approach which addressed the third tier. Regarding the deterministic approach, the Domenico (1987) ground water contaminant transport model was replaced by a new set of analytical solutions that consider different geometries of contamination sources used in cases of instantaneous and continuous release of contaminants. This replacement allowed for the utilization of the RBCA methodology whenever the Domenico (1987) analytical model does not apply. A comparison between this set of analytical solutions with another set used to validate and testify the chosen set only, showed great solution stability response; whereas, the models of comparison have demonstrated instability for high values of the time variable. Such a fact proved the validity of the use of the proposed set of analytical solutions inserted in a health risk assessment context. In the context of the stochastic approach of risk estimation, the Monte Carlo method was employed to propagate uncertainties over one of the analytical solutions mentioned above, from which results were obtained to simulate dermal contact with contaminated surface water while swimming exposure pathway. The results of the stochastic simulation demonstrated a high correlation between the risk and the variable C (contaminant concentration), which was modeled by the hydraulic conductivity stochastic simulation. Hence, it may be concluded that the hydraulic conductivity affects the risk estimation, for which a difference of six orders of magnitude between the minimum and maximum simulated values and two orders of magnitude for the real risk value was observed.
105

Estudo geotécnico de dois taludes da formação serra geral, RS

Perazzolo, Lilian January 2003 (has links)
Esta dissertação de mestrado apresenta um estudo sobre dois taludes coluvionares localizados na região nordeste do Rio Grande do Sul, inseridos no contexto geológico da Formação Serra Geral. Estes taludes apresentam características e comportamento geotécnico distintos. O objetivo desta dissertação é obter parâmetros de condutividade hidráulica e resistência ao cisalhamento dos solos presentes nos dois taludes, a fim de entender os diferentes processos de ruptura observados. Um dos taludes, denominado talude de Canastra, apresenta um processo de rastejo; este talude tem uma inclinação bastante suave e apresenta uma camada de colúvio sobre um solo residual de basalto vesicular. O talude de Canastra apresenta uma camada de transição entre o colúvio e o solo residual; os ensaios de condutividade hidráulica realizados em campo mostraram que esta camada é menos permeável do que o colúvio e o solo residual, formando uma camada quase impermeável e criando condições para a formação de dois níveis freáticos neste talude. Nos solos deste talude foi detectada a presença significante de argila expansiva (montmorilonita). O outro talude estudado, denominado de talude da rodovia RS470, apresentou uma ruptura abrupta após um período de intensa chuva. Este talude apresenta uma inclinação bastante íngreme e um solo coluvionar assente diretamente sobre basalto alterado. A condutividade hidráulica deste colúvio é bastante elevada. O colúvio apresenta pouca argila expansiva, sendo formado essencialmente por caulinita. Os ensaios ring shear, realizados para a obtenção de parâmetros de resistência ao cisalhamento residual nos solos dos dois taludes, apresentaram valores muito baixos de φr, inferiores a 10° Valores semelhantes foram encontrados por Pinheiro (2000) e Rigo (2000) em solos residuais de basalto da Formação Serra Geral. Foram realizadas simulações numéricas de fluxo d’água e de estabilidade destes taludes, na tentativa de verificar as condições em que aconteceram os escorregamentos.
106

Estudo da distribuição dimensional de poros e da condutividade hidráulica de solos arenosos compactados tratados com cal e cimento / Study of the pore dimensional distribution and hydraulic conductivity of sandy compacted soils treated with lime and cement

Ibeiro, Lidiane da Silva January 2016 (has links)
A técnica de estabilização de solos através da incorporação de agentes cimentantes é uma opção eficaz e amplamente utilizada em obras de engenharia geotécnica. Portanto, são relevantes os estudos que contemplam aspectos ainda não bem compreendidos relativos aos efeitos causados pela adição de agentes cimentantes na porosidade dos materiais obtidos e, por consequência, nas propriedades de desempenho destas misturas. Neste sentido, o presente trabalho pretende contribuir no que tange ao conhecimento da estrutura de poros de solos compactados tratados com cal e cimento e sua relação com o comportamento hidráulico destes materiais. Os solos utilizados têm granulometria arenosa e areno-siltosa. As variáveis de controle envolvidas nas análises são os teores dos agentes de cimentação empregados (cal e cimento), densidades de compactação e tempos de cura (para amostras com cal). Para a caracterização dos sistemas de poros empregou-se porosimetria por intrusão de Mercúrio e, de forma complementar, na quantificação das porosidades globais, microtomografia computadorizada de raios x. Um permeâmetro de parede flexível foi utilizado para as determinações das condutividades hidráulicas das amostras estudadas através de ensaios de carga constante. Para as amostras de matriz arenosa pura, os volumes de intrusão indicaram maior refinamento da rede porosa, sob efeito da cimentação, para as condições mais densas de moldagem. Para as amostras de matriz areno-siltosa, ao se variarem as condições de cimentação, e fixando-se o peso específico aparente seco, os volumes intrudidos indicaram o refinamento dos poros quando da adição de cal ou cimento em comparação à condição não cimentada. Com respeito à análise da influência do tempo de cura para as amostras moldadas com cal, os resultados sugeriram que a adição de cal (aos 7 dias de cura) não causou variação da porosidade, comparada à condição sem cimentação, mas aos 28 dias foi possível perceber o aumento da porosidade global e, com o passar do tempo (180 dias) verificou-se a redução da porosidade. O refinamento dos poros se tornou cada vez mais pronunciado conforme a evolução do tempo. Para a matriz arenosa, foi identificado que a adição de cimento e a variação da porosidade de moldagem não implicaram em mudanças mensuráveis no valor da condutividade hidráulica, quando comparadas às condições com e sem cimento. Para as amostras da matriz areno-siltosa, sob diferentes condições analisadas (adição de cal aos diferentes tempos investigados e adição de cimento), foi evidenciado que o peso específico aparente seco de moldagem causou influência significativa sobre a condutividade hidráulica. Foram obtidos bons ajustes para as correlações condutividade hidráulica versus relação porosidade/teor volumétrico do agente cimentante ao se aplicar a potência de 0,032 sobre o parâmetro teor volumétrico do agente cimentante. As curvas obtidas apresentaram relações distintas e sinalizaram aspectos do comportamento do material: aumento da condutividade hidráulica para 28 dias de cura da cal, em relação a 7 dias; para 180 dias e amostras nas condições menos densas, não ocorreu modificação em relação à idade de 28 dias, mas na condição mais densa o parâmetro investigado tornou-se sensível às modificações promovidas por efeitos do tempo de cura; ainda, para as amostras moldadas com cimento, ocorreu redução mais pronunciada da condutividade hidráulica relacionada às condições mais densas de moldagem. / The soil stabilization technique which incorporates cementing agents is an effective alternative and widely used in geotechnical engineering works. Therefore, research on the aspects not well understood related to the effects caused by the addition of cementing agents on the porosity of the obtained materials and, consequently, on the performance properties of cemented blends, are relevant. In this sense, this study aims to contribute improving the knowledge on the pore structure of compacted soils treated with lime and cement, as well as to the relationship between pore structure and the hydraulic behavior of these materials. The used soils have a sandy and sandy-silty grain size distribution. The studied variables involved in the analysis are: the cement and lime contents; compaction density; and curing time (for samples with lime). To characterize the pore systems it was employed the Mercury intrusion porosimetry test and, additionally, in order to quantify the global porosities, it was used x-ray computed microtomography tests. A flexible wall permeameter was used to determinate the hydraulic conductivity of the samples through constant head tests. For sandy samples, the intrusion volumes indicated a more significant reduction of the porous media, under the effect of the cementation, when compacted in denser conditions. For the sandy-silt samples, it was observed that by maintaining the specific dry unit weight constant and by varying the cementation conditions, the intruded volumes indicated a reduction of the pores after the addition of lime or cement compared to the uncemented samples. With regards to the influence of the curing time for samples treated with lime, the results suggested that the addition of lime after 7 days of curing did not cause variation in porosity, compared to condition without cementing additions; however, after 28 days of curing it was observed a slight increase on the overall porosity and, after 180 days of curing, it was observed a reduction of the porosity. The reduction of the pores became more significant with the curing time. Related to the sandy soil, the results indicated that addition of cement to the soil and variations on the molding porosity did not result in measurable changes in the hydraulic conductivity, when compared the conditions with and without cement. For the sandy-silt samples, which were analyzed under different conditions (addition of lime and different curing times, and addition of cement), it was shown that the specific dry unit weight caused significant influence on the hydraulic conductivity. It was observed a satisfactory correlation between hydraulic conductivity and porosity/cementing agent ratio when the volumetric cementing agent content is to the power of 0,032. The obtained curves showed distinct relationships and indicated the following aspects of the material behaviour: the increasing of the hydraulic conductivity after 28 days of curing of the sample with lime, compared to 7 days of curing; after 180 days of curing and under low compaction conditions, it was observed no changes when compared to the samples tested after 28 days of curing; however, in the densest condition the investigated parameter became dependent on the curing time; moreover, for the samples molded with cement, it was observed a more significant reduction of the hydraulic conductivity related to denser molded conditions.
107

Estudo dos solos de uma encosta instável em São José - SC : intemperismo e comportamento geotécnico / Study of soils of an unstable slope in São José – SC : weathering and geotechnical behavior

Heidemann, Marcelo January 2015 (has links)
Uma encosta localizada no município de São José - SC apresenta extenso histórico de instabilidades. Do ponto de vista litológico há predominância de granitoides na área de estudos e a mesma é transpassada por uma falha preenchida por riolito bastante alterado devido à atividade hidrotermal. O intemperismo da rocha granítica deu origem a um perfil de alteração com espessura bastante variável e a solos com características geotécnicas, químicas e mineralógicas distintas, levando à discretização de cinco solos. Quatro solos residuais foram denominados solos residuais de granito amarelo (GrAm), vermelho (GrVm), com biotita (GrBt) e lateritizado (GrLt), e uma argila de preenchimento de descontinuidades (ArBr). Foi realizada uma série de análises químicas, empregadas na quantificação de índices de intemperismo. O avanço do processo de intemperismo tornou os solos residuais mais finos e plásticos e nas áreas em que a alteração hidrotermal foi mais intensa houve a transformação de feldspatos em biotitas. As curvas de retenção solo-água obtidas para os solos saprolíticos são unimodais, mas no caso do solo GrLt os dados experimentais ajustam-se a curvas bimodais. O processo de remoldagem dos solos impacta nos níveis de sucção desenvolvidos. Os ensaios de condutividade hidráulica mostraram que esta propriedade não depende unicamente da porosidade e nível de confinamento, sendo relevante a influência da estrutura e mineralogia. Os solos saprolíticos tem comportamento distinto do apresentado pelo solo GrLt, no qual ocorre brusca redução de ksat com aumento do confinamento. Ensaios de compressão confinada em amostras indeformadas, remoldadas e reconstituídas possibilitaram identificar a manifestação da estrutura e sua influência na deformabilidade dos solos. Constatou-se que esta suplanta a influência da porosidade. Não é possível definir uma única linha de compressão normal que descreva o comportamento de cada material independentemente da forma com que foram preparados os corpos de prova. Nos ensaios triaxiais a estrutura dos materiais atua de forma distinta daquela observada nos ensaios oedométricos, indicando que sua influência depende da trajetória de tensões. A mineralogia parece ter influência na resistência ao cisalhamento destes solos. O solo GrBt apresentou o mais baixo ângulo de atrito, da ordem de 26º. O solo GrVm tem ângulo de atrito de 32º, sendo o maior aqui obtido. Quando remoldados os solos respeitam linhas de estado crítico (CSL) bastante bem definidas, por conta da redução da influência da estrutura nos resultados. Quando indeformados também é possível o ajuste de CSL, mas a dispersão dos dados é maior. O comportamento dos solos não é normalizável, mesmo quando remoldado. Em ensaios ring shear foram medidos ângulos de atrito residual entre 22º (GrAm) e 13,8º (GrLt) nos solos residuais. No solo ArBr o baixo ângulo de atrito residual (8º) se deve à granulometria fina e composição rica em argilominerais e micas. Sua associação ao solo GrBt corrobora a concentração das rupturas de encosta na área de ocorrência destes materiais. As curvas tensão-deformação dos ensaios triaxiais puderam ser satisfatoriamente reproduzidas pelo modelo hardening, o qual foi empregado para representar o comportamento dos solos em análises de estabilidade por meio de elementos finitos. Tais análises foram confirmadas por análises por equilíbrio limite no que tange a definição de áreas mais suscetíveis a rupturas. / A hillside in the municipality of São José - SC has an extensive history of instabilities. Under a lithological point of view, there is a predominance of granitoids in the study area, which is crossed by a fault filled by an altered rhyolite, due to hydrothermal activity. The weathering of the granite rock gave rise to a soil profile with highly variable thickness and soils with distinct geotechnical, chemical and mineralogical properties, leading to the discretization of five soils. They were denominated as four granite residual soils, yellow (GrAm), red (GrVm), with biotite (GrBt) and lateritizated (GrLt), and a clay soil that filled discontinuities (ArBr). A series of chemical analysis was carried out and employed to quantify some weathering indexes. As the weathering processes increased the residual soils became finer and more plastic. In areas where hydrothermal alteration was more intense feldspar was transformed in biotite. Soil suction characteristic curves obtained for the saprolitic soils were unimodal, but in the case of GrLt soil bimodal curves fitted better to experimental data. Remolding of the soils impacted the suction levels developed. Hydraulic conductivity tests have shown that this property does not depend solely on the porosity and confining pressures but the influence of soil structure and mineralogy is relevant. The saprolitic soils show a different behavior as compared to GrLt, which suffers abrupt reduction of ksat when the confinement is increased. Oedometric tests on undisturbed, remolded and reconstituted specimens allowed the identification of the influence of structure on the soil deformability. It was found that this influence is larger than that of porosity. It was not possible to define a unique normal compression line to describe the behavior of each material, regardless of the specimens preparation. In triaxial tests, soil structure acts in a different way from the observed in oedometric tests, indicating that their influence depends on the stress path. The mineralogy appears to have influence on the shear strength of these soils. The soil GrBt has the lowest friction angle, around 26°, and soil GrVm has a friction angle of 32° the largest obtained. When remolded these soils obey critical state lines which are well defined due to the reduction of soil structure influence. Although was possible to define CSL for the undisturbed soil the data dispersion was bigger. These soils do not have normalizable behavior even when remolded. Residual friction angles of residual soils measured through ring shear tests ranged between 22° (GrAm) and 13,8º (GrLt). The soil ArBr showed a very low residual friction angle (8°) due to its fine grain size and its mineralogical composition rich in clay minerals and mica. The association of ArBr soil to the GrBt soil supports the concentration of slope failures in the area of occurrence of these materials. Stress-strain curves of triaxial tests were satisfactorily reproduced by the hardening model, which was employed to represent the soils behavior in stability analyzes using finite element method. Such results were validated by limit equilibrium analysis that were employed to define the areas more susceptible to failures.
108

Comportamento hidráulico e mecânico de um solo residual tratado com cal

Benetti, Mozara January 2015 (has links)
A abordagem do comportamento hidráulico associado ao comportamento mecânico de um material é de extrema importância. A técnica de tratamento de solos com cal vem sendo empregada com sucesso na engenharia geotécnica, melhorando as características do solo, que por ser um material complexo e variável nem sempre satisfaz as necessidades requeridas para um projeto. Nesse sentido, este estudo tem por objetivo quantificar a influência da quantidade de cal e da porosidade sobre o comportamento hidráulico e mecânico de um solo residual tratado com cal, verificando a adequação do uso da relação vazios/cal na estimativa da condutividade hidráulica, da resistência à compressão simples (qu) e da resistência à tração (qt). Para isso, foram realizados ensaios de condutividade hidráulica e de resistência para corpos de prova com 5%, 7% e 9% de cal, com peso específico aparente seco de 16,0 kN/m³, 17,2 kN/m³ e 18,5 kN/m³, curados por 28 dias. Foi observado que a porosidade da mistura é um parâmetro de influência sobre a condutividade hidráulica medida. Ambas as resistências, à compressão simples e à tração por compressão diametral, aumentaram potencialmente com a redução da porosidade. Verificou-se uma única relação qt/qu igual a 0,13, sendo independente da relação vazios/cal. A metodologia proposta por Consoli (2014), mostrou-se adequada para a determinação dos parâmetros de resistência (intercepto coesivo e ângulo de atrito) para uma relação [n/(Liv)0,12=35. A relação vazios/cal, definida pela razão entre a porosidade da mistura compactada e o teor volumétrico de cal, ajustado por uma potência, demonstrou ser um parâmetro eficaz na estimativa do comportamento hidráulico e mecânico do solo-cal estudado. / The approach of the hydraulic behavior associated with the mechanical behavior of a material is of utmost importance. The technique of treating soil with lime has been used successfully in geotechnical engineering, improving the characteristics of the soil, which is a highly variable and complex material, and does not always meet the required needs. In that sense, this study has for objective to quantify the influence of amounts of lime and of the porosity on the hydraulic and mechanical behavior a sandy silt soil stabilized with lime, checking the suitability of the use de voids/ lime ratio in estimating of the hydraulic conductivity, unconfined compression strength (qu) and tensile strength (qt). For that, number of hydraulic conductivity tests and strength tests were carried out for soil-hydrated lime blends, with lime contents of 5%, 7% e 9%, dry unit weight of 16,0 kN/m³, 17,2 kN/m³ and 18,5 kN/m³, 28 days as curing time. It was observed that the porosity of the mixture is a parameter influence on the hydraulic conductivity measured. The results show the unconfined compressive and the splitting tensile strength increasing potentially with the reduction of its porosity. It was found a single qt/qu relationship equal to 0,13, being independent of the porosity/lime ratio. The methodology suggested by Consoli (2014), was adequate for determining of Mohr-Coulomb failure parameters (effective cohesion intercept effective angle of shearing resistance) for a ratio [n/(Liv)0,12=35. The voids/lime ratio, defined as the ratio between the porosity of the compacted mixture and volumetric lime content, adjusted by a power, demonstrated to be the most appropriate parameter to assess the hydraulic and mechanical behavior of the soil-lime mixture studied.
109

Simulação estocástica dos impactos das mudanças climáticas sobre as demandas de água para irrigação na região noroeste do Rio Grande do Sul

Melo, Tirzah Moreira de January 2015 (has links)
Esta tese foi desenvolvida para avaliar os impactos das mudanças climáticas ao longo deste século sobre as demandas futuras de água para irrigação da soja na região Noroeste do Estado do Rio Grande do Sul sob uma abordagem estocástica e considerando diferentes projeções de modelos climáticos para o período de 2011-2100, comparando com o passado (1961-1990). As demandas de água para irrigação da soja (IWR) foram obtidas por simulação com o modelo SWAP. O aspecto estocástico desta avaliação foi conduzido pela incorporação da variabilidade espacial da condutividade hidráulica do solo (Ksat) e dos parâmetros da curva de retenção de água no solo (CR). Inicialmente, foi realizada uma análise estocástica destes atributos físico-hidráulicos na bacia do Arroio Donato (1,1 Km2), a qual serviu de área representativa dos solos e do uso do solo da região Noroeste. Foi empregada a técnica de simulação sequencial Gaussiana (SSG) para geração de 100 campos aleatórios de cada variável. Os resultados revelaram maiores incertezas para Ksat e o parâmetro α da CR e permitiu identificar que a grande heterogeneidade espacial e temporal das variáveis analisadas pode estar associada a fatores tais como clima, manejo e cobertura do solo, erros de amostragem, adensamento da malha amostral e também ao grau de compactação do solo. Em seguida foi feita uma investigação para detectar mudanças nos padrões de temperatura (T) e precipitação (P) na região Noroeste do RS (~65.000 Km2) pelo uso de diferentes modelos climáticos de circulação geral e regional (MCGs e MCRs, respectivamente). Sete distintas localizações na região foram consideradas, para as quais há dez diferentes projeções climáticas destes modelos. Adicionalmente, também foram investigadas a frequência e a intensidade de eventos de precipitação extrema utilizando-se de índices de eventos extremos. As projeções indicam um aumento na média anual de temperatura de quase 3ºC até o final do século, bem como um aumento na precipitação anual. Também foi realizada uma análise sazonal de T e P, a qual demonstrou que os maiores aumentos de temperatura são projetados para o inverno e início da primavera e, portanto, não coincidem com os meses de verão da principal cultura da região (soja). De posse das informações anteriores, o modelo SWAP foi utilizado para estimar as demandas de água para irrigação da soja (IWR), sem considerar perdas devido à eficiência de qualquer método de irrigação. Foram feitos também testes de hipóteses sobre as séries de IWR simuladas e os resultados suportam a premissa de que IWR a curto prazo (2025s) não será estatisticamente diferente do período base (1961-1990). Por outro lado, as IWR em 2055s e 2085s rejeitam esta hipótese. Por fim, avaliou-se a influência da distribuição espacial da condutividade hidráulica saturada (Ksat) e dos parâmetros do modelo da curva de retenção de água no solo (α, n e sat) sobre as demandas futuras de água para a irrigação da soja (IWR), segundo uma abordagem estocástica. Os valores simulados pelo método geoestatístico de simulação sequencial Gaussiana foram utilizados como dados de entrada no modelo SWAP. Como dados meteorológicos foram consideradas apenas as projeções do modelo climático regional ETA 20 e ETA 40 CTRL, bem como as projeções dadas pelo modelo climático global HADCM3 nas sete localizações na região. As estimativas obtidas pelo método estocástico foram então comparadas com as estimativas de IWR obtidas sem considerar a variabilidade espacial dos atributos físico-hidráulicos do solo. Os resultados indicaram grande variabilidade espacial dos valores de IWR. Além disso, observou-se que as menores incertezas de IWR foram obtidas a partir das projeções do modelo de melhor resolução espacial, o ETA 20, enquanto o modelo HADCM3 revelou as maiores diferenças entre os períodos futuros e o período atual (base). Os resultados também demonstraram que a maior incerteza é devido aos modelos climáticos, pois a abordagem estocástica praticamente não agregou incerteza aos valores de IWR simulados anteriormente. Por fim, as séries de IWR obtidas pela abordagem determinística e estocástica foram comparadas pelo teste de hipóteses de Kolmogorov-Smirnov, o qual comprovou que as séries só não diferem a curto prazo (2025s) e que, portanto, a variabilidade espacial do solo não pode ser negligenciada nas estimativas desta variável. / This Thesis has been developed to assess the impacts of climate change throughout this century on future water demands for soybean irrigation in the Northwest region of Rio Grande do Sul under a stochastic approach and considering different projections of climate models for the period 2011-2100, compared to the past (1961-1990). The water demands for irrigation (IWR) were obtained by simulation with the SWAP model. The stochastic aspect of this evaluation was conducted by incorporating the spatial variability of the saturated hydraulic conductivity (Ksat) and the parameters of the soil water retention curve (CR). Initially, a stochastic analysis of soil physical-hydraulic attributes (Ksat and CR parameters) in the Donato basin (1,1 Km2) was carried out. This basin served as a representative area of soils and land uses of the Northwest region. The Sequential Gaussian Simulation (SSG) technique was used to generate 100 random fields of each variable. The results revealed greater uncertainty for Ksat and for α parameter of the CR and identified that the large spatial and temporal heterogeneity of the variables may be associated with factors such as climate, management and land cover, sampling error, spatial density of the sampling grid and also the degree of soil compaction. After, an investigation was made to detect changes in temperature (T) and precipitation (P) patterns in the Northwest region of RS (~65.000 Km2) by using different global and regional circulation models (GCM and RCM, respectively). Seven distinct locations in the region were considered, for which there are ten different climate projections of these models. Additionally, it was also investigated the frequency and intensity of extreme rainfall events using extreme event indices. Projections indicate an increase in average annual temperature of almost 3 °C by the end of this century, as well as an increase in annual precipitation. It was also performed a seasonal analysis of T and P, which showed that the largest temperature increases are projected for the winter and early spring and, therefore, do not coincide with the summer months the main crop in the region (soy). Making use of the above information, the SWAP model was applied to estimate the water demand for soybean irrigation (IWR), excluding losses due to the efficiency of any method of irrigation. A hypothesis test for the simulated IWR series and the results supports the premise that in short-term IWR (2025s) is not statistically different from base period (1961-1990). On the other hand, IWR in 2055s and 2085s reject this hypothesis. Finally, the influence of the spatial distribution of the saturated hydraulic conductivity (Ksat) and the parameters of the soil water retention curve (α, sat and n) on IWR was evaluated, according to a stochastic approach. The simulated values form the geostatistical method of Sequential Gaussian Simulation (SGS) were used as input data in the SWAP model. Input data of meteorological information were provided by the projections of regional climate model ETA 20 and ETA 40 CTRL, as well as the projections given by global climate model HADCM3 for the seven locations in the region. Estimates obtained by the stochastic method were then compared with the IWR estimates obtained without considering the spatial variability of physical and hydraulic soil properties. The results indicated large spatial variability of IWR values. Furthermore, it was observed that the smallest uncertainties of IWR were obtained from the projections with better spatial resolution, the ETA 20 model, while the HADCM3 model revealed the highest differences between future periods and the current period (baseline). The results also showed that the greatest uncertainties are probably due to climate models, since the stochastic approach did not add uncertainties to the IWR values simulated previously. Finally, the series of IWR obtained by stochastic and deterministic approaches were compared by the hypothesis test of Kolmogorov-Smirnov, which proved that only the series in the short term (2025s) differ, and, therefore, the soil spatial variability may not be neglected when estimating this variable.
110

Soluções analíticas para transporte de hidrocarbonetos do petróleo em água subterrânea : avaliação determinística e probabilística do risco à saúde humana

Melo, Tirzah Moreira de January 2010 (has links)
O presente trabalho apresenta um estudo de caso de contaminação de solo e água subterrânea por derivados do petróleo em uma refinaria da região Sudeste do país, para o qual foram aplicados todos os níveis ou tiers da metodologia RBCA de avaliação de risco à saúde humana. Diferentes vias de exposição foram consideradas ao longo de toda a metodologia, a qual foi dividida em determinística, compreendendo os dois primeiros níveis, e estocástica, no caso do terceiro nível. Sobre a abordagem determinística, o modelo de Domenico (1987) para transporte de contaminantes em água subterrânea foi substituído por um conjunto de soluções analíticas que considera diferentes geometrias de fonte de contaminação para casos instantâneos e contínuos de liberação de contaminantes, permitindo que a metodologia RBCA também possa ser empregada mesmo quando o modelo de Domenico (1987) não se aplica. A comparação deste conjunto de soluções com outro utilizado apenas para comparar e confirmar a validade dos modelos escolhidos demonstrou grande estabilidade nas soluções, enquanto os modelos de comparação apresentaram instabilidade nas soluções para altos valores da variável tempo. Tal fato comprovou a viabilidade do emprego do conjunto de soluções analíticas proposto para avaliação de risco à saúde humana. No contexto da abordagem estocástica da estimativa do risco, o método de Monte Carlo foi empregado para propagação das incertezas sobre uma das soluções analíticas citadas anteriormente, da qual, por sua vez, foram extraídos os resultados para a simulação estocástica do risco para a via de contato dermal com água superficial contaminada por Benzeno. Os resultados da simulação estocástica demonstraram uma correlação muito grande do risco com a variável C (concentração do contaminante), a qual, por sua vez, foi modelada pela simulação estocástica da condutividade hidráulica. Logo, pode-se concluir que a condutividade hidráulica afeta a estimativa do risco, para o qual observou-se uma diferença de seis ordens de magnitude entre o valor mínimo e o máximo simulados e duas ordens de magnitude para o valor real do risco. / This dissertation presents a case study on soil and ground water contamination by components derived from petroleum in a refinery located in the Southeast region of Brazil. All of the RBCA health risk assessment methodology tiers were applied in this study. Different exposure pathways were considered throughout the methodology. Firstly, the deterministic approach which encompasses the first two tiers and secondly, the stochastic approach which addressed the third tier. Regarding the deterministic approach, the Domenico (1987) ground water contaminant transport model was replaced by a new set of analytical solutions that consider different geometries of contamination sources used in cases of instantaneous and continuous release of contaminants. This replacement allowed for the utilization of the RBCA methodology whenever the Domenico (1987) analytical model does not apply. A comparison between this set of analytical solutions with another set used to validate and testify the chosen set only, showed great solution stability response; whereas, the models of comparison have demonstrated instability for high values of the time variable. Such a fact proved the validity of the use of the proposed set of analytical solutions inserted in a health risk assessment context. In the context of the stochastic approach of risk estimation, the Monte Carlo method was employed to propagate uncertainties over one of the analytical solutions mentioned above, from which results were obtained to simulate dermal contact with contaminated surface water while swimming exposure pathway. The results of the stochastic simulation demonstrated a high correlation between the risk and the variable C (contaminant concentration), which was modeled by the hydraulic conductivity stochastic simulation. Hence, it may be concluded that the hydraulic conductivity affects the risk estimation, for which a difference of six orders of magnitude between the minimum and maximum simulated values and two orders of magnitude for the real risk value was observed.

Page generated in 0.1168 seconds