• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 177
  • 3
  • 2
  • Tagged with
  • 183
  • 183
  • 127
  • 123
  • 101
  • 76
  • 38
  • 36
  • 35
  • 26
  • 25
  • 23
  • 20
  • 20
  • 19
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
121

Estudo do comportamento hidráulico de mistura solo-bentonita visando alternativa de emprego como sistema de proteção para aterros sanitários / Study of the hydraulic behavior of soil-bentonite mixture seeking employment as protection system for sanitary landfills

Christopher Fonseca da Silva 27 February 2015 (has links)
Este trabalho apresenta um estudo sobre a influência do acréscimo de 4% de bentonita sódica, da anisotropia inerente, produzida pela compactação, e do estado de tensões no comportamento hidráulico de um solo areno-argiloso encontrado na região Costeira Sul do estado do Rio Grande do Sul. Neste estudo, busca-se não somente viabilizar o emprego do referido solo como barreira mineral em obras de proteção ambiental, mas também verificar seu desempenho, quando misturado ao aditivo, perante as condições de fluxo de água experimentalmente impostas, antes e depois da fase de consolidação, nas direções normal e paralela aos planos de orientação preferencial das partículas e poros a elas associados. Com o escopo de atingir tais objetivos, executaram-se dois métodos de compactação (ensaios Mini e Proctor Normal) para a moldagem de corpos de prova com planos de orientação preferencial das partículas ou de compactação normais (θ = 90º) e paralelos (θ = 0º) à vertical. As amostras de solo e mistura foram compactadas na energia Proctor Normal e submetidas aos ensaios triaxiais de condutividade hidráulica, em permeâmetro de parede flexível à carga constante, e de consolidação. A técnica permitiu determinar a condutividade hidráulica dos materiais para vazões desenvolvidas preferencialmente nas direções normal e paralela aos planos de compactação dos corpos de prova. Os resultados demonstram que o acréscimo de 4% de bentonita sódica provoca uma redução da condutividade hidráulica do solo, que supera o valor mínimo exigido de 10-9 m/s em ambas as direções de fluxo, habilitando o emprego deste material para a aplicação prevista. Além disso, verifica-se que a compactação confere um comportamento hidráulico anisotrópico ao solo, no entanto, quando misturado ao aditivo no teor indicado, seu comportamento se modifica, tornando-se mais isotrópico. Os resultados ainda revelam que o efeito da tensão de confinamento sobre a diminuição da condutividade hidráulica do solo e da mistura se mostra significativo para ambas as modalidades experimentais. / This work proposes to evaluate the influence of the inherent anisotropy, promoted by compaction, and the confining pressure on the hydraulic behavior of a clayey sand from the south coastal region of Rio Grande do Sul state (Brazil), in pure condition and mixed with 4% sodium bentonite content. This study aims to make possible the use of this soil as mineral barrier in environmental protection works, as well as evaluating the hydraulic behavior of both materials (soil and mixture), before and after the consolidation stage, when developed water flow conditions in the perpendicular and parallel directions in relation to the compaction planes of the compacted samples. In order to achieve these objectives, was performed a Standard Proctor Test and an alternative compaction test (Mini-test), intending to get specimens with compaction planes in the perpendicular (θ= 90º) and parallel (θ = 0º) directions in relation to the vertical. The soil and mixture samples were compacted at Normal Proctor energy and subjected to the triaxial consolidation and hydraulic conductivity tests. The technique allowed to evaluate the hydraulic conductivity of the specimens for flow perpendicular and parallel to the directions of the compaction planes. The results indicate that the increase of 4% sodium bentonite content reduces the hydraulic conductivity of the soil in both flow directions, making it suitable for employment as protection system in sanitary landfills or in other similar applications. Furthermore, it is observed that compaction provides anisotropic hydraulic behavior to the soil, however, when it is mixed with 4% sodium bentonite content, its behavior changes, becoming more isotropic. The results also reveal that the effect of the confining pressure on the decrease in hydraulic conductivity of the soil and mixture is significant in both adopted experimental conditions.
122

Atributos foliares e anatômicos do xilema em espécies de árvores e lianas da Floresta Atlântica / Architecture, life history and liana infestation of tree species in semideciduous forests from Campinas, SP

Dias, Arildo de Souza, 1979- 19 February 2013 (has links)
Orientadores: Fernando Roberto Martins, Rafael Silva Oliveira / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Biologia / Made available in DSpace on 2018-08-22T21:00:03Z (GMT). No. of bitstreams: 1 Dias_ArildodeSouza_D.pdf: 101885895 bytes, checksum: 1d2644f73311bbbaee1346d9d6c59e1b (MD5) Previous issue date: 2013 / Resumo: Compreender como espécies de plantas diferenciam-se em relação a atributos funcionais para aquisição e utilização de recursos, e se a relação entre esses atributos varia em função de diferenças ambientais, como pluviosidade total e sazonalidade, e uma forma de construir uma ecologia mais preditiva no contexto das mudanças climáticas globais. Nesta tese investigamos como arvores e lianas se diferenciam em relação a atributos funcionais da folha dos ramos. Analisamos-nos se o relacionamento entre esses atributos diferia considerando a variação de pluviosidade e sazonalidade de duas fitofiosionomias da Floresta Atlântica, a floresta ombrofila densa (FO) e a floresta estacional semedicidua (FS). Encontramos diferenças não são na amplitude, mas também na forca do relacionamento entre os atributos funcionais foliares estudados. Essas diferenças parecem ser determinadas pela diferença ambiental entre as duas florestas estudadas e por características intrínsecas do habito de crescimento de lianas e arvores. A anatomia do xilema das espécies de lianas e arvores da FO difere em relação à das espécies da FS, mesmo quando consideramos o parentesco filogenético. Por investir pouco em tecidos de sustentação esperava-se menor conteúdo de lignina nos ramos de lianas, entretanto nosso resulto foi o oposto. Encontramos a razão S/G dos monômeros syringil e guaiacil que compõe a lignina menor que um para duas espécies de lianas. Indicando que ha maior deposição de lignina em vasos de xilema do que em fibras. Esse fato pode estar relacionado à maior eficiência em condutividade hidráulica de lianas ou a requerimentos biomecânicos específicos dos ramos de lianas. Em particular, ressalta-se o fato de que lianas foram mais eficientes em captar luz (menor MFA) e tiveram maior condutividade hidráulica potencial (Kp) do que arvores na FS. A maior competitividade de lianas frente arvores apenas na FS tem implicação importante no cenário de mudanças climáticas / Abstract: Understanding how plant species differentiated in functional traits for resources acquisition and use, and if the relationships among those traits vary in according with environmental characteristics such as rainfall and seasonality, could lead to a more predictive science in the context of global change. Here we investigate how trees and lianas differ in leaf and xylem anatomical traits related to water transport and hydraulic architecture. We analyze the relationships among those traits taking into account the variation in rainfall and seasonality between two types of Atlantic Forest, semediciduous seasonal forest (SF) and the dense ombrophilous forest (OF). We found differences not only in range, but in the strength of the relationship among leaf functional traits, which in turn could be related to environmental differences between the two forests studied. The xylem anatomy of lianas and tree species of OF differ compared to species of SF despite taking to account the phylogenetic relatedness. Since lianas have low investment in support tissues we expected lower lignin content in the branches of lianas. However, we found the opposite pattern. Another unexpected result found for two liana species was the ratio to the monomers syringyl and guayacil present at lignin (S/G) lower than one. This result indicates that there is more deposition of lignin in xylem vessel walls than fibers, what in turn would be linked to greater efficiency in hydraulic conductivity of lianas or to specific biomechanical requirements of the branches of lianas. In particular, we highlighted the fact that liana species are more efficient in light acquisition (lower LMA) and had higher hydraulic conductivity (Kp) relative to trees just in the SF. These lianas competitive advantages over trees have important implications in the context of climatic changes / Doutorado / Biologia Vegetal / Doutor em Biologia Vegetal
123

Hidrodinâmica em área úmida de cerrado na chapada sedimentar do oeste mineiro /

Furlan, Lucas Moreira January 2019 (has links)
Orientador: Vania Silvia Rosolen / Resumo: No Brasil, a captação de água para irrigação é de aproximadamente 1000 m³/s, caracterizando o maior consumo de água do território nacional. Como possível ambiente de estoque natural de água que cobre quase 20% do território, as áreas úmidas vem sendo drasticamente reduzidas pela conversão do uso da terra. As áreas úmidas promovem a infiltração das águas superficiais e caracterizam áreas de recarga de aquíferos. Nesse sentido, medidas e modelos relacionados aos solos com propriedades hidromórficas e seu papel na recarga de aquíferos constituem um desafio para compreender a dinâmica entre solo e água, a fim de atender o desenvolvimento sustentável. Neste estudo, análises baseadas em sensoriamento remoto, com o uso de sensores ópticos de alta resolução espaço-temporal a bordo de Veículos Aéreos Não Tripulados (VANT), associadas ao uso de técnicas não invasivas que permitem o mapeamento da arquitetura subsuperficial dos sistemas pedológicos (ensaios geofísicos de Eletrorresistividade, por Tomografia Elétrica), foram aplicadas para compreender a relação água-solo superficial e subsuperficial em uma área úmida da chapada sedimentar do oeste mineiro. A integração destes dados com ensaios in situ de permeabilidade e de densidade e granulometria dos solos, permitiu uma abordagem ampla e tridimensional do comportamento dos parâmetros hidrogeológicos na área úmida. Os resultados permitiram determinar que a área úmida estudada é uma depressão que possui três compartimentos com distinções... (Resumo completo, clicar acesso eletrônico abaixo) / Mestre
124

Condutividade hidráulica não saturada de um solo arenoso: aplicação do infiltrômetro de disco / Unsaturated hydraulic conductivity of a sandy soil using the disk infiltrometer

Fernandes, Mariana Alher 23 September 2011 (has links)
A função condutividade hidráulica é um dos parâmetros essenciais para o estudo do fluxo em solos não saturados, permitindo abordar, dentre outros, o avanço da frente de umedecimento e questões como a irrigação e drenagem de solos. Para determinar a condutividade hidráulica não saturada de um solo típico da região Centro-Oeste do Estado de São Paulo, utilizou-se o infiltrômetro de disco. Este equipamento permite conduzir a infiltração de água, estando esta sujeita a um potencial negativo. Com os dados de infiltração acumulada e tempo acumulado obtidos em cada ensaio, foi possível determinar os valores da condutividade hidráulica não saturada e sortividade. Os cálculos foram feitos por diferentes métodos para cada ensaio realizado com o infiltrômetro de disco e comparadas com resultados de ensaios utilizando o permeâmetro Guelph. Observou-se que as condutividades hidráulica não saturadas obtidas com o infiltrômetro de disco tenderam a valores próximos das fornecidas indiretamente por meio do permeâmetro Guelph, com dispersão de aproximadamente uma ordem de grandeza para cada sucção. Também se observou que a condutividade hidráulica não saturada tende a diminuir conforme aumenta a sucção imposta ao solo, mesmo considerando a estreita faixa de sucções usadas nos ensaios. Notou-se ainda pequena variação nas condutividades hidráulicas saturadas calculadas por meio do infiltrômetro de disco, por meio de medidas diretas utilizando o permeâmetro Guelph e ensaios de permeabilidade realizados em laboratório. / The hydraulic conductivity function is essential to the study of water flow in unsaturated soils. From function there can be derived the advancement of the humidification (saturation) front, among other parameters, which is essential to projects of irrigation and drainage of soils. A disk infiltrometer was used to determine the unsaturated hydraulic conductivity of a sample of typical soil from central São Paulo, Brazil. The disk infiltrometer apparatus conducts the infiltration water, which is held at negative potential. Data for cumulative infiltration and elapsed time for each test was used to determine values of unsaturated hydraulic conductivity and sorptivity. Different methodology was applied in the calculations. Data for each experiment carried out utilizing the disk infiltrometer was compared to data obtained utilizing the permeameter of Guelph. It was observed that the unsaturated hydraulic conductivity obtained through the disk infiltrometer yielded values near those obtained indirectly by the permeameter of Guelph, which showed dispersion approximately within one order of magnitude for each suctioning performed. Furthermore, it was observed that the unsaturated hydraulic conductivity tends to diminish in magnitude in an inverse relation to the suction pressure subjected by the soil, even after considering the narrow band of suction pressures carried out in the tests. It was further observed a small variation in the saturated hydraulic conductivities computed from data obtained directly from the infiltrometer disk, the permeameter of Guelph, and other permeability tests done in laboratory.
125

Condutividade hidráulica de solos compactados em ensaios com permeâmetro de parede flexível / Hydraulic conductivity of compacted soils in flexible wall permeameter tests

Alonso, Thiago de Paula 16 September 2005 (has links)
Cincos solos compactados do estado de São Paulo foram estudados para uso como barreira impermeável de aterros sanitários. Foram realizados ensaios em permeâmetro de parede flexível com utilização do sistema de controle hidráulico de volume constante (sistema fechado), ensaios em permeâmetro de parede rígida e ensaios de contração. Verificou-se que menores valores de condutividade hidráulica estão associados a teores de umidade de moldagem igual ou acima do teor de umidade ótimo fornecida no ensaio de Proctor normal. Teores de umidade acima do ótimo e graus de compactação superiores a 100% não causaram significativas reduções na condutividade hidráulica, que tende a se estabilizar a partir destes parâmetros. Foram sugeridas condições de compactação para quatro dos cinco solos analisados, de forma que a condutividade hidráulica não excedesse 1.'10 POT.-7' cm/s, valor sugerido para barreiras impermeáveis. A contração axial e volumétrica não foi influenciada pelo teor de umidade de moldagem e grau de compactação, para corpos-de-prova compactados nas condições de compactação sugeridas. Os resultados de condutividade hidráulica em ensaios com permeâmetros de parede rígida se mostraram, aproximadamente, uma ordem de grandeza menor se comparados aos resultados obtidos com permeâmetro de parede flexível, porém essa diferença diminuiu com o aumento do grau de compactação dos corpos-de-prova / The hydraulic conductivity of five compacted soils from São Paulo state is studied aiming at their use in lining systems. Permeability tests were performed in flexible wall permeameters with constant volume hydraulic control system (closed system), rigid wall permeameters and contraction tests. It was verified that lower values of hydraulic conductivity are associated to molding water content equal or larger than optimum water content of soil as measured in standard Proctor. Molding water content beyond optimum and compaction degree lager than 100% did not cause significant reduction on hydraulic conductivity, which tends to stabilize when those parameters are reached. It is proposed ideal conditions of compaction for four of five compacted soils studied with hydraulic conductivity not lager than '10 POT.-7' cm/s, suggested value for lining systems. The axial and volumetric shrinkage was not influenced by water content and compaction degree, for specimen compacted on ideal conditions suggested here. The hydraulic conductivity results of greatness lower when compared to the results of the flexible wall permeameter, although that difference gets smaller with the rise of compaction degree
126

Condutividade hidráulica do solo no campo: as simplificações do método do perfil instantâneo. / Field soil hydraulic conductivity: the simplification of the instantaneous profile method.

Carvalho, Laercio Alves de 23 January 2003 (has links)
Sendo a condutividade hidráulica do solo um parâmetro que traduz a facilidade com que a água se movimenta ao longo do perfil de solo, sua determinação, principalmente no campo, torna-se imprescindível, visto que o movimento da água no solo está diretamente relacionado à produção das culturas agrícolas. Com isso, a aplicação de um método confiável que quantifique a condutividade hidráulica versus umidade, a função ( ) q K , certamente contribuirá muito para uma correta avaliação dos resultados, principalmente tendo em conta a grande variabilidade dessa função devido à variabilidade natural das características do solo. Neste trabalho, testou-se o método do perfil instantâneo com o objetivo de avaliar a função ( ) q K com e sem a suposição de gradiente unitário e também o seu comportamento com relação aos os horizontes pedológicos do solo. A determinação da função foi feita usando tensiômetros com manômetros de mercúrio instalados às profundidades de 0,1; 0,2; 0,3; 0,4; 0,5; 0,6; 0,7; 0,8; 0,9; 1,0; 1,1 e 1,2 m e curvas de retenção determinadas para as mesmas profundidades, num Latossolo Vermelho Distrófico argissólico A moderado textura média, localizado no campo experimental da Escola Superior de Agricultura "Luiz de Queiroz", Universidade de São Paulo. A análise dos resultados foi feita pelo teste F de análise de variância, a fim de testar o paralelismo, a igualdade dos interceptos e a coincidência entre as retas lnK versus q, considerando e não considerando a suposição do gradiente unitário. Além disso, foram feitos também testes de similaridade da função ( ) q K de cada profundidade do solo pelo índice de concordância de Willmott (1981). Com base na análise dos resultados pode-se dizer que, com os procedimentos utilizados de delimitação da área para inundação e redistribuição da água, podem ser empregados modelos simples que consideram unitário o gradiente de potencial total e que, pela comparação feita entre as profundidades, a separação do perfil do solo em horizontes pedológicos parece seguir a separação em camadas com funções ( ) q K semelhantes, apenas a partir da profundidade 0,6 m. / The soil hydraulic conductivity is a parameter that quantifies the ability of the soil to conduct water along the soil profile. Hence its field determination is indispensable, since soil water movement is directly related to the field crop productions. Thus, the use of an adequate method that assesses the hydraulic conductivity as a function of soil-water content, the ( ) q K function, certainly will very contribute to a proper evaluation of results, mainly if it is considered the great variability of this function as a result of the natural variability of the soil characteristics. In this work, the instantaneous profile method was tested with the objective to evaluate a) the ( ) q K function taking and not taking into consideration the assumption of unit gradient and b) the behaviour of the ( ) q K function with respect to the pedological horizons of the soil. The determination of the function was made using mercury manometer tensiometers installed at the depths of 0.1; 0.2; 0.3; 0.4; 0.5; 0.6; 0.7; 0.8; 0.9; 1.0; 1.1 and 1.2 m and soil water retention curves determined for the same depths, in an Oxisol, located at experimental fields of Escola Superior de Agricultura Luiz de Queiroz, University de São Paulo, in Piracicaba (SP), Brasil (22 o 42’ 43,3’’ W and 47 o 37’ 10,4’’ S). The result analysis was made using an F-test in order to verify the paralelism, the intercept equality and the coincidence of the lnK versus q straight lines, taking and not taking account of the assumption of unit hydraulic gradient. Basides, similarity tests of the ( ) q K function were also made by the Willmott (1981) index. From the analysis of results, it could be concluded that, with the procedures used to delimit the experimental plots in this experiment to water the soil profile and to follow the water redistribuition, the unit gradient approches seem to be adequate to assess the field ( ) q K function and also that the pedological horizons seem to follow the layers of similar ( ) q K function, for depths greater than 0.6 m.
127

Comportamento anisotrópico de um solo laterítico compactado / Anisotropic behavior of a compacted laterite soil

Santos, Roberto Aguiar dos 04 December 2015 (has links)
A compactação de aterros pode gerar comportamento anisotrópico, a depender do teor de umidade de compactação, entre outros fatores. O principal objetivo deste estudo foi investigar alguns aspectos relacionados à anisotropia inerente induzida pela compactação de um solo laterítico. Após realizar a caracterização mineralógica, geotécnica e microestrutural deste solo, estudou-se a resistência ao cisalhamento, condutividade hidráulica, compressibilidade e deformabilidade. O solo estudado foi classificado como laterítico arenoso (LA\') e apresentou agregação relativa da ordem de 12%. A metodologia desenvolvida no intuito de corrigir o aumento na massa específica seca das camadas inferiores, causado pelo processo de compactação, mostrou-se eficaz. A partir da curva de compactação foram consideradas amostras representativas das três condições de umidade de compactação: ramo seco, umidade ótima e ramo úmido. Corpos de prova foram talhados paralelamente e ortogonalmente às camadas de compactação. Os ensaios de porosimetria revelaram um comportamento bimodal na distribuição do tamanho de poros e também que o teor de umidade de compactação não interferiu no tamanho dos microporos. Para o solo compactado no ramo seco e na umidade ótima, a resistência ao cisalhamento correspondente à direção ortogonal se mostrou superior àquela correspondente à direção paralela às camadas de compactação. Por outro lado, a resistência ao cisalhamento no ramo úmido mostrou-se praticamente independente da direção de talhagem dos corpos de prova. Este comportamento se deve à maior capacidade do solo, em um dado teor de umidade, em absorver a energia aplicada e distribuí-la na direção paralela e ortogonal. Com relação às propriedades elásticas do material, observou-se que o aumento do teor de umidade de compactação contribui para redução da anisotropia de deformabilidade. Dentre as propriedades investigadas, a anisotropia de condutividade hidráulica das amostras correspondente ao ramo úmido foi a mais pronunciada, exibindo fluxo oito vezes maior na direção vertical que na horizontal. Finalmente, as discussões e análises presentadas nesta pesquisa mostraram que o grau de anisotropia depende diretamente do teor de umidade de compactação e que diminui com incremento das tensões aplicadas no solo. / Compacted embankments can have anisotropic behavior, depending on several factors, including the compaction water content. The aim of this study was to investigate some aspects regarding the inherent anisotropy of a lateritic soil, caused by the compaction process. After performing the geotechnical, mineralogical and microstructural characterization, properties of shear strength, hydraulic conductivity, compressibility and deformability were investigated. This soil this soil was classified as lateritic sand. The grainsize distribution curve indicates 12% the fine particle aggregation. The methodology developed in order to correct the increase in dry density of the lower layers, generated by the compression process, was effective. From the compaction curve, representative samples corresponding to the three compaction water content conditions, representing the dry side, the optimal water content and the wet side were considered. Specimens were trimmed parallel and orthogonally to the compaction layers. The porosimetry tests showed a bimodal behavior in the pore size distribution and also that the compaction water content did not influence the size of the micropores. For the compacted soil sample corresponding to the dry side and optimum water content, the shear strength corresponding to the orthogonal direction was higher than that corresponding to the parallel direction to the compaction layers. However, they were almost equal for both the orthogonal and the parallel directions to the compaction layers. This behavior is due to the higher capacity of the soil at a given moisture content, to absorb the energy applied and distribute it in parallel and orthogonal direction. The analysis the values of maximum shear modulus of the material showed that increasing compaction water content reduces the anisotropy degree. Among the investigated properties, the hydraulic conductivity anisotropy of the samples corresponding to the wet branch was the most pronounced, showing permeability eight times higher in the vertical direction than that in the horizontal direction. Finally, the discussions and analyzes presented in this study showed that the degree of anisotropy directly depends on the compaction water content and decreases with increase confining stress applied to the soil specimens.
128

Avaliação da condutividade hidráulica e da resistência ao cisalhamento de misturas solo-bentonita: estudo de caso de um aterro sanitário localizado em Rio Grande (RS) / Evaluation of hydraulic conductivity and shear strength of soil-bentonite mixtures: a case study of a landfill located in Rio Grande (RS)

Camargo, Karina Retzlaff 15 October 2012 (has links)
A utilização do solo natural compactado com bentonita empregado em camadas impermeáveis para retenção de contaminantes é bastante usual para aterros sanitários. Neste trabalho são apresentados resultados de ensaios condutividade hidráulica e de resistência ao cisalhamento, realizados em equipamentos triaxiais. Além do solo natural, foram utilizadas misturas solo-bentonita nos teores de 2%, 4% e 6%. O solo arenoso ensaiado é encontrado na Planície Costeira Sul do Estado do Rio Grande do Sul. Os valores de condutividade hidráulica diminuiram tanto com o acréscimo do teor de bentonita, quanto com o aumento da tensão de confinamento. A condutividade hidráulica do solo apresentou uma redução de três ordens de grandeza quando este foi compactado com 6% de bentonita (de \'10 POT.-7\' para \'10 POT.-10\' m/s). Em relação a resistência ao cisalhamento do material, constatou-se que com o acréscimo do teor bentonita de 0 para 6%, a coesão efetiva aumentou (de 2,3 para 12,8 kPa) e o ângulo de atrito efetivo diminuiu (de 22,7º pra 14,0º). / Compacted soil-bentonite mixtures used as impermeable layers for retention of contaminants is quite usual in landfills. This paper presents the results of hydraulic conductivity and shear strength tests conducted in a triaxial apparatus. Natural soil, and soil-bentonite mixtures at 2%, 4% and 6% concentrations were tested. The sandy soil tested is found in the Southern Coastal Plain of Rio Grande do Sul. The hydraulic conductivity decreased with both the increase of bentonite content and increase of confining stress. Compared to natural soil, the hydraulic conductivity of compacted soil-bentonite mixtures at 6% content decreased by three orders of magnitude (from \'10 POT.-7\' to \'10 POT.-10\' m/s). Regarding the material shear strength, it was found that when the natural soil is compared to compacted soil-bentonite mixtures at 6% content, the effective cohesion increased (from 2.3 to 12.8 kPa) and the effective friction angle decreased (from 22. 7º to 14.0º).
129

Cultivo de roseiras em ambiente protegido sob níveis de salinidade do solo e relações nitrogênio:potássio / Greenhouse rose crop under different level of soil salinity and nitrogen:potassium fertilization ratios

Silva, Everaldo Moreira da 16 April 2013 (has links)
A produção de rosas em ambiente protegido sob fertirrigação é uma técnica bastante utilizada pelos floricultores. Em ambiente protegido o manejo nutricional é realizado de forma mais intensa que nas condições de campo, priorizando-se a adubação via fertirrigação. Na fertirrigação a relação nitrogênio:potássio é um fator relevante nos parâmetros de produtividade e qualidade das flores de rosas. Neste sentido, o objetivo desse trabalho foi avaliar o efeito da salinidade causada por excesso de aplicação de fertilizantes via fertirrigação associadas a diferentes relações nitrogênio:potássio (N:K) sobre os parâmetros biométricos e produtivos da roseira cultivada em ambiente protegido. O monitoramento da condutividade elétrica (CE) e das concentrações de nitrato e potássio na solução do solo, ao longo do ciclo da cultura, foram realizadas com o uso da TRD. Ao final do ciclo avaliou-se a extração de macronutrientes no tecido vegetal das hastes, folhas e botões florais. O experimento foi conduzido no período de 03 de março a 03 de novembro de 2012 na área experimental do Departamento de Engenharia de Biossistemas da Escola Superior de Agricultura \"Luiz de Queiroz\", em Piracicaba, SP. Com 22º 42\' de latitude sul e 47º 38\' de longitude oeste e uma altitude de 540 m. Foi adotado o delineamento em blocos casualizados completos, arranjados em esquema fatorial (5 x 3 + 1), com quatro repetições, totalizando 64 parcelas, sendo a unidade experimental representada por uma parcela com dimensões de 0,40 m de largura por 0,50 m de profundidade e 2,0 m de comprimento. Os tratamentos foram formados pela combinação de cinco níveis iniciais de condutividade elétrica (CEes: 1,2; 2,3; 3,3; 4,3 e 5,5 dS m-1), a serem mantidos constantes ao longo do ciclo da roseira e três relações nitrogênio:potássio (N:K) (2:1; 1:2 e 1:3) e uma testemunha com relação N:K (1:1). A irrigação foi realizada por gotejamento, utilizando um fator de depleção de água no solo de 0,3 para o manejo da irrigação. A umidade do solo foi monitorada com o uso de sondas TRD e de tensiômetros providos de transdutores de pressão. Os níveis de salinidade do solo provenientes do acúmulo de sais fertilizantes afetaram diretamente as variáveis: número e comprimento de hastes, matéria fresca e seca das hastes e botões florais. Diante dos resultados obtidos, observou-se que, as variáveis diâmetro de botão e índice de área foliar não sofreram influência em relação aos tratamentos impostos. Isoladamente as relações N:K não influenciaram nenhum parâmetro avaliado. As concentrações de N, K, P, Ca e Mg nos tecidos vegetais aos 245 dias após o transplantio (DAT), foram afetadas pelos tratamentos impostos. As maiores concentrações foram observadas nas folhas, sendo o nitrogênio o elemento de maior concentração, seguido pelo potássio. Com o uso da sonda TDR no manejo da fertirrigação foi possível manter os níveis desejados de salinidade da solução do solo ao longo do tempo, bem como as concentrações de nitrato (NO3-) e potássio (K+). A salinidade limiar do solo para a cultura da roseira foi de 2,52 dS m-1. / The fertigation is a technique often used in the greenhouse rose crop by flower famers. Under greenhouse conditions the nutritional management is often more intense than under field conditions, as a result, the application of fertilizers is applied by fertigation. In the fertigation, nitrogen and potassium fertilization ratios are important parameters which determine yield and quality of the rose flowers. Therefore, the objective of this research was to evaluate the effect of soil salinity, due to the excessive fertilizers application by fertigation, associated with different nitrogen-potassium ratios (N:K) on biometric and productive parameters of the greenhouse rose crop. The electrical conductivity (EC), nitrogen and potassium levels in the soil solution were measured by TDR sensors during crop cycle. At the end of the crop cycle, macronutrients extractions in the stems, flower buds and flowers were measured. The experiment was carried out from 03/03/2012 to 11/03/2012 in the experimental field area of Department of Biosystems Engineering at \"Luiz de Queiroz\" College of Agriculture, in Piracicaba, Sao Paulo State, Brazil. The place are located in the latitude 22º 42\' south and longitude 47º 38\' west with 540 m of the altitude. The statistical design was a randomized complete block, organized in a factorial scheme (5 x 3 + 1), with four repetitions and 64 parcel in total. Each experimental unit was represented for each parcel with dimensions 0.40 m of width, 0.50 m of depth and 2 m of length. Treatments were a combination of five initial EC levels (EC: 1.2; 2.3; 3.3; 4.3 and 5.5 dS m-1) which were maintained constant during de rose crop and three nitrogen-potassium fertilization ratios (N:K - 2:1; 1:2 e 1:3), and one witness with N:K ratio of 1:1. The irrigation was realized by drip system and it was utilized a soil-water depletion factor of 0.3 to irrigation management. The soil moisture was measured by TDR sensors and tensiometer with pressure transducers. Soil salinity levels due to the fertilizers accumulation affected directly the variables: stem number, stem length; dry and fresh matter of the stems and flower buds. Flower bud diameter and leaf area index were not affected by the imposed treatments. Nitrogen-potassium ratios did not affect any evaluated parameter. N, K, P, Ca and Mg concentration in the tissues at 245 days after planting (DAT) were affected by imposed treatment. Biggest concentration were found in the leaves which nitrogen showed the highest concentration followed by potassium. TDR sensors allowed maintaining the salinity levels in the soil solution at the desired levels during crop cycle, and also the nitrogen (NO3-) and potassium concentrations (K+). Threshold salinity of soil for the culture of the rose was (2.52 dS m-1).
130

Barreiras de solos estabilizados com cal e cimento para proteção ambiental / Soil barriers chemically stabilized with lime and cement to environmental protection

Loch, Felipe de Campos 16 December 2013 (has links)
Este trabalho apresenta a avaliação dos efeitos da estabilização química com cal e cimento na condutividade hidráulica e resistência à compressão de um solo arenoso proveniente da Formação Botucatu (Estado de São Paulo, Brasil), com o objetivo de obter um material menos permeável e mais resistente. O projeto e análise de experimentos foram realizados através de um planejamento fatorial 3², com duas variáveis independentes: teor de umidade e porcentagem de estabilizante, variando em três níveis cada. Foi utilizado cal hidratada CH-III, cimento Portland CP II-Z32 e água fornecida pela concessionária local. Os ensaios de condutividade hidráulica (K) foram executados em permeâmetros de carga constante. Foram realizados ensaios de resistência a compressão simples (RC) após 7 e 28 dias de cura. As amostras de solo estabilizado e natural foram compactadas na energia Proctor Normal. Na avaliação da estrutura das amostras de solo estabilizado verificou-se a alteração da matriz de poros promovida pela adição de cal e cimento. Após a obtenção dos resultados, análises estatísticas possibilitaram avaliar os efeitos das variáveis independentes sobre o K e RC. Pelo método de superfície de respostas foi possível demonstrar o comportamento das misturas e identificar a tendência de alteração das propriedades. As amostras de solo-cimento alcançaram reduções de condutividade hidráulica de até 9,5 x 10-7 m/s e o menor valor experimental de K foi de 1,4 x 10-8 m/s. Os ensaios de RC, com 28 dias de cura, apresentaram acréscimo de resistência de até 5,1 MPa e os resultados obtidos possuem uma variação, aproximadamente, entre 0,1 e 5,1 MPa. O procedimento adotado permitiu avaliar a influência dos fatores e determinar as misturas ótimas para cada estabilizante. / A laboratory study was conducted to evaluate the effects of lime and cement stabilization over the hydraulic conductivity and unconfined compressive strength of a sandy soil from Botucatu Formation (São Paulo State, Brazil) with the intend to generate a less permeable and more resistant material. The experiment was performed using the technique of factorial design 3², with the two independent variables: moisture content and stabilizer percentage, varying on three levels each. Hydraulic conductivity (K) was measured in constant-head permeameters. Unconfined compressive strength (CS) was measured after 7 and 28 days of curing. The samples of stabilized and natural soils were compacted with the normal Proctor energy. The evaluation of the stabilized soil structure verified a pore matrix modification promoted by lime and cement addition. With the results of the characterization, statistical analysis allowed to assess the effects of the variable factors on K and CS. The response surface method was used to demonstrate the hydraulic and compressive strength behavior of the stabilized soil. The soil-cement hydraulic conductivity achieved reductions up to 9.5 x 10-7 m/s and the lowest K experimental value was 1.4 x 10-8 m/s. The compressive strength, with 28 days of curing, presented an increase in CS up to 5.1 MPa and the obtained results showed a range between 0.1 and 5.1 MPa. The adopted experimental procedure allows the assessment of the variables influence and the determination of the optimal mixtures for each stabilizer.

Page generated in 0.1343 seconds