• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 58
  • 6
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 66
  • 32
  • 17
  • 14
  • 14
  • 13
  • 13
  • 13
  • 12
  • 11
  • 11
  • 10
  • 10
  • 10
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Biossegurança: avaliação da eficácia de válvulas antirrefluxo em sistemas de infusão na radiologia / Biosafety: efficacy evaluation of non-return valves in infusion systems in radiology

Azevedo, Marcela Padilha Facetto 11 April 2018 (has links)
Na radiologia, válvulas antirrefluxo (VARs) são utilizadas em tubos de infusão para realização de exames de ressonância magnética e tomografia computadorizada. O objetivo desta pesquisa foi investigar procedimentos associados ao uso de VARs em exames radiológicos, a fim de contribuir para a biossegurança, controles da contaminação e do risco de infecção em sistemas de infusão. Uma Revisão Integrativa (RI) a respeito das VARs utilizadas na área da saúde foi realizada no que concerne os aspectos físicos, de funcionalidade e microbiológicos. A pressão máxima, em contra fluxo, dos diafragmas flexíveis (DFs) íntegros e rompidos das VARs foi determinada com auxílio do equipamento Hydraulic Burst-Leak Tester (HB-LT). A funcionalidade das VARs foi verificada por inspeção visual, em contra fluxo, mediante a liberação de bolhas de ar em um recipiente com água, por meio de simulação artificial da pressão da corrente sanguínea humana (SAPCSH). A estrutura e integridade das VARs foram identificadas por inspeção visual. A performance de colunas de ar interpostas por água em conectores com VARs foi analisada por inspeção visual (SAPCSH). A distância da difusão de um contaminante (cristal violeta) através de conectores com VARs foi mensurado por inspeção visual e espectrofotômetro (SAPCSH). A eficácia das VARs, em contra fluxo, como barreira de contaminação bacteriana foi avaliada em um experimento bacteriológico (SAPCSH). Um procedimento operacional padrão (POP) foi elaborado para direcionar a prática adequada do manuseio dos conectores com VARs, visando a biossegurança, controles da contaminação e do risco de infeção em sistemas de infusão em radiologia. Os resultados demostraram que houve diferença entre as pressões máximas suportadas pelos DFs dos Patient-set®: íntegros (média e desvio padrão: 595,44 ± 39,38psi) e rompidos (média e desvio padrão: 90,22 ± 31,26psi), em contra fluxo (p<0,0001). Por outro lado, os Patient-set® com os DFs rompidos não demonstraram falha na funcionalidade das VARs, mediante a ausência da liberação de bolhas de ar. Ainda, as VARs dos Patient-set® demonstraram DFs rompidos, entretanto as outras estruturas continuaram íntegras. As colunas de ar podem ser comprimidas e se deslocar através dos Patient-set® com DFs íntegros e rompidos. Além disso, a maior distância de difusão do cristal violeta foi de 30% (6cm) do comprimento do conector (20cm) do Patient-set®. Outrossim, a técnica de mensuração por espectrofotômetro (absorbância) foi mais sensível do que por inspeção visual para esse propósito. As VARs dos Patient-set® mostraram eficácia como barreira de contaminação bacteriana (Staphylococcus aureus resistente à meticilina, 10psi por 2h30min). Ademais, um POP foi elaborado e validado para a utilização e manuseio dos Patient-set®, visando a biossegurança na prática clínica, controles da contaminação e do risco de infecção em sistemas de infusão em radiologia como recomendação original a ser disponibilizada a todos os profissionais da área. Em suma, a biossegurança dos sistemas de infusão na radiologia depende de vários aspectos físico, de funcionalidade e microbiológico das VARs atrelados à execução adequada na prática clínica. Além disso, pesquisas adicionais são necessárias para elucidar questionamentos futuros sobre o uso seguro das VARs / In radiology, non-return valves (NRV) are used in infusion tubes to perform magnetic resonance imaging and computed tomography scan exams. The objective of this research was to investigate procedures associated to NRV usage in radiologic exams, in order to contribute to biosafety, contamination and infection risk controls in infusion systems. An Integrative Review (IR) about NRVs utilized in health field was performed concerning physical, functionality, and microbiological aspects. The maximum pressure, in backflow, of whole and broken flexible diaphragms (FDs) from NRVs was determined with Hydraulic Burst-Leak Tester (HB-LT) equipment help. The NRVs functionality was verified by visual inspection, in backflow, by means of air bubbles release in a water container, through human bloodstream pressure artificial simulation (HBPAS). The NRVs structure and integrity were identified by visual inspection. The performance of air columns interposed by water in connectors with NRVs was analyzed by visual inspection (HBPAS). Diffusion distance of a contaminant (crystal violet) through connectors with NRVs was measured by visual inspection and spectrophotometer (HBPAS). The NRVs efficacy, in backflow, as barrier to bacterial contamination was evaluated in a bacteriological experiment (HBPAS). A standard operating procedure (SOP) was elaborated to direct the proper handling of connectors with NRVs, aiming at biosafety, contamination and infection risk controls in infusion systems in radiology. The results showed that there was difference among maximum tolerated pressures by FDs of Patient-set®: whole (mean and standard deviation: 595.44 ± 39.38psi) and broken (mean and standard deviation: 90.22 ± 31.26psi), in backflow (p<0.0001). On the other hand, the Patient-set® with broken FDs didn\'t show failure in NRVs functionality, through the lack of air bubbles release. Moreover, NRVs showed broken FDs, but the other structures remained whole. The air columns can be compressed and move through Patient-set® with whole and broken FDs. Besides, the longest diffusion distance of crystal violet was 30% (6cm) of connector length (20cm) of Patient-set®. Furthermore, the measure technique by spectrophotometer (absorbance) was more sensitive than by visual inspection for this purpose. Patientset® NRVs showed efficacy as barrier to bacterial contamination (Methicillin-resistant Staphylococcus aureus, 10psi for 2h30min). Moreover, a SOP was elaborated and validated for Patient-set® utilization and handling, aiming at biosafety in clinical practice, contamination and infection risk controls in infusion systems in radiology as original recommendation to be made available to all professionals in the field. In conclusion, the biosafety depends on various physical, functionality, and microbiological aspects of NRVs coupled with proper practical clinical performance. Besides, further researches are needed to elucidate future questionings about NRVs safe use
52

Simulação numérica do comportamento de conectores de cisalhamento tipo crestbond / Numerical simulation of the behavior of crestbond shear connectors

Silva, Halley Pereira da 28 January 2013 (has links)
Made available in DSpace on 2015-03-26T13:28:14Z (GMT). No. of bitstreams: 1 texto completo.pdf: 5185340 bytes, checksum: 2affa702a631cd03bd10eb05ee16522a (MD5) Previous issue date: 2013-01-28 / In the latest years, several studies about shear connectors in perforated flat steel plates have been conducted in order to assess its application in composite structures of steel and concrete, including experimental and numerical approaches. Nevertheless, the behavior of these connectors remains a subject of investigation. This work presents the development of a numerical model capable of simulating the behavior of steel-concrete connection with Crestbond shear connectors using the Finite Element Method. The numerical analysis was performed using the ABAQUS software, considering the elastoplastic behavior for steel and the Concrete Damage Plasticity model for concrete. In order to validate the numerical model, experimental results obtained by Veríssimo (2007) and Oliveira (2007) were used for comparisons. In numerical simulations were evaluated the influence of concrete constitutive model, and the influence of the steelconcrete connection representation using two strategies: Tie restrictions and contact interactions between surfaces. These strategies proved to be able to adequately represent the phenomena observed in laboratory tests, especially those that used contact interactions between surfaces. The numerical model is suitable for simulating the structural behavior of Crestbond connectors, being able to represent the interaction between steel and concrete, to characterize the maximum load resisted by the connection and to characterize the deformation of the connector, providing a useful tool for several other studies. / Nos últimos anos, vários estudos sobre conectores de cisalhamento em chapas planas de aço perfuradas têm sido conduzidos, com vistas à sua aplicação em estruturas mistas de aço e concreto, incluindo abordagens experimentais e numéricas. Apesar disso, o comportamento desses conectores ainda permanece como objeto de investigações. Neste trabalho, apresenta-se o desenvolvimento de um modelo numérico capaz de simular o comportamento da ligação aço-concreto com conectores de cisalhamento Crestbond, utilizando o Método dos Elementos Finitos. A análise numérica foi feita por meio do software ABAQUS, considerando-se o comportamento elastoplástico para o aço e a aplicação do Modelo de Dano Plástico para o concreto. Para validação do modelo numérico, foram utilizados resultados experimentais obtidos por Veríssimo (2007) e por Oliveira (2007). Nas simulações numéricas foram avaliadas a influência do modelo constitutivo do concreto e a influência do modo de representação da ligação aço-concreto através de duas estratégias: utilização de restrições tipo Tie e utilização de interações de contato entre superfícies. Estas estratégias mostraram-se capazes de representar adequadamente os fenômenos observados nos ensaios de laboratório, principalmente quando se utilizaram interações de contato entre superfícies. O modelo numérico desenvolvido é adequado para a simulação do comportamento estrutural dos conectores Crestbond, sendo capaz de representar a interação entre aço e concreto, de caracterizar a carga máxima resistida pela conexão e de caracterizar as deformações do conector, constituindo uma ferramenta útil para vários outros estudos.
53

Conectores sequenciadores em artigos de opini?o escritos por vestibulandos: uma quest?o de marca??o lingu?stia com implica??es para o ensino

Andrade, Fl?via Ang?lica de Amorim 22 August 2011 (has links)
Made available in DSpace on 2014-12-17T15:06:59Z (GMT). No. of bitstreams: 1 FlaviaAAA_DISSERT.pdf: 1000597 bytes, checksum: 5370c4e6e2788ff4fe785c8c97c10d9c (MD5) Previous issue date: 2011-08-22 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior / 0 / Nesta disserta??o, ? luz do Funcionalismo Lingu?stico Norte-americano, analisamos conectores sequenciadores em produ??es textuais escritas do vestibular 2009.1 do Instituto Federal de Educa??o, Ci?ncia e Tecnologia do Rio Grande do Norte (IFRN). Nosso objetivo principal ? verificar se os empregos dados a esses conectores em artigos de opini?o produzidos em situa??o de vestibular s?o influenciados pelo princ?pio da marca??o lingu?stica, segundo o qual formas mais marcadas tendem a ser utilizadas em contextos mais complexos e formas menos marcadas tendem a ser utilizadas em contextos menos complexos. Controlamos quatro grupos de fatores sint?tico-sem?nticos e sem?ntico-pragm?ticos aptos a mensurar graus de complexidade relativos ao contexto de uso de conectores: n?veis de articula??o textual, rela??es sem?ntico-pragm?ticas, tra?os sem?ntico-pragm?ticos verbais e tipos de sequ?ncias textuais. Os resultados obtidos nos permitiram avaliar a influ?ncia que o princ?pio da marca??o lingu?stica exerce sobre o uso de conectores sequenciadores em artigos de opini?o produzidos por vestibulandos. O conector E, menos marcado, predomina em contextos de menor complexidade, ao passo que os demais conectores encontrados em nossa amostra, todos definidos como mais marcados, predominam em contextos de maior complexidade. Observamos, ainda, haver uma grande frequ?ncia do conector E nas produ??es textuais averiguadas, ao lado de uma baixa frequ?ncia dos demais conectores. Al?m disso, mapeamos tr?s tipos distintos de inadequa??o entre o conector sequenciador utilizado e a rela??o sem?ntico-pragm?tica pretendida e/ou obtida. Com base nesses resultados, sugerimos algumas atividades para os n?veis fundamental e m?dio de ensino, com o intuito de contribuir com um ensino de L?ngua Portuguesa que vise ? diversifica??o dos conectores sequenciadores empregados em artigos de opini?o, bem como ? adequa??o desses conectores a contextos de menor ou maior complexidade e a diferentes rela??es sem?ntico-pragm?ticas
54

Biossegurança: avaliação da eficácia de válvulas antirrefluxo em sistemas de infusão na radiologia / Biosafety: efficacy evaluation of non-return valves in infusion systems in radiology

Marcela Padilha Facetto Azevedo 11 April 2018 (has links)
Na radiologia, válvulas antirrefluxo (VARs) são utilizadas em tubos de infusão para realização de exames de ressonância magnética e tomografia computadorizada. O objetivo desta pesquisa foi investigar procedimentos associados ao uso de VARs em exames radiológicos, a fim de contribuir para a biossegurança, controles da contaminação e do risco de infecção em sistemas de infusão. Uma Revisão Integrativa (RI) a respeito das VARs utilizadas na área da saúde foi realizada no que concerne os aspectos físicos, de funcionalidade e microbiológicos. A pressão máxima, em contra fluxo, dos diafragmas flexíveis (DFs) íntegros e rompidos das VARs foi determinada com auxílio do equipamento Hydraulic Burst-Leak Tester (HB-LT). A funcionalidade das VARs foi verificada por inspeção visual, em contra fluxo, mediante a liberação de bolhas de ar em um recipiente com água, por meio de simulação artificial da pressão da corrente sanguínea humana (SAPCSH). A estrutura e integridade das VARs foram identificadas por inspeção visual. A performance de colunas de ar interpostas por água em conectores com VARs foi analisada por inspeção visual (SAPCSH). A distância da difusão de um contaminante (cristal violeta) através de conectores com VARs foi mensurado por inspeção visual e espectrofotômetro (SAPCSH). A eficácia das VARs, em contra fluxo, como barreira de contaminação bacteriana foi avaliada em um experimento bacteriológico (SAPCSH). Um procedimento operacional padrão (POP) foi elaborado para direcionar a prática adequada do manuseio dos conectores com VARs, visando a biossegurança, controles da contaminação e do risco de infeção em sistemas de infusão em radiologia. Os resultados demostraram que houve diferença entre as pressões máximas suportadas pelos DFs dos Patient-set®: íntegros (média e desvio padrão: 595,44 ± 39,38psi) e rompidos (média e desvio padrão: 90,22 ± 31,26psi), em contra fluxo (p<0,0001). Por outro lado, os Patient-set® com os DFs rompidos não demonstraram falha na funcionalidade das VARs, mediante a ausência da liberação de bolhas de ar. Ainda, as VARs dos Patient-set® demonstraram DFs rompidos, entretanto as outras estruturas continuaram íntegras. As colunas de ar podem ser comprimidas e se deslocar através dos Patient-set® com DFs íntegros e rompidos. Além disso, a maior distância de difusão do cristal violeta foi de 30% (6cm) do comprimento do conector (20cm) do Patient-set®. Outrossim, a técnica de mensuração por espectrofotômetro (absorbância) foi mais sensível do que por inspeção visual para esse propósito. As VARs dos Patient-set® mostraram eficácia como barreira de contaminação bacteriana (Staphylococcus aureus resistente à meticilina, 10psi por 2h30min). Ademais, um POP foi elaborado e validado para a utilização e manuseio dos Patient-set®, visando a biossegurança na prática clínica, controles da contaminação e do risco de infecção em sistemas de infusão em radiologia como recomendação original a ser disponibilizada a todos os profissionais da área. Em suma, a biossegurança dos sistemas de infusão na radiologia depende de vários aspectos físico, de funcionalidade e microbiológico das VARs atrelados à execução adequada na prática clínica. Além disso, pesquisas adicionais são necessárias para elucidar questionamentos futuros sobre o uso seguro das VARs / In radiology, non-return valves (NRV) are used in infusion tubes to perform magnetic resonance imaging and computed tomography scan exams. The objective of this research was to investigate procedures associated to NRV usage in radiologic exams, in order to contribute to biosafety, contamination and infection risk controls in infusion systems. An Integrative Review (IR) about NRVs utilized in health field was performed concerning physical, functionality, and microbiological aspects. The maximum pressure, in backflow, of whole and broken flexible diaphragms (FDs) from NRVs was determined with Hydraulic Burst-Leak Tester (HB-LT) equipment help. The NRVs functionality was verified by visual inspection, in backflow, by means of air bubbles release in a water container, through human bloodstream pressure artificial simulation (HBPAS). The NRVs structure and integrity were identified by visual inspection. The performance of air columns interposed by water in connectors with NRVs was analyzed by visual inspection (HBPAS). Diffusion distance of a contaminant (crystal violet) through connectors with NRVs was measured by visual inspection and spectrophotometer (HBPAS). The NRVs efficacy, in backflow, as barrier to bacterial contamination was evaluated in a bacteriological experiment (HBPAS). A standard operating procedure (SOP) was elaborated to direct the proper handling of connectors with NRVs, aiming at biosafety, contamination and infection risk controls in infusion systems in radiology. The results showed that there was difference among maximum tolerated pressures by FDs of Patient-set®: whole (mean and standard deviation: 595.44 ± 39.38psi) and broken (mean and standard deviation: 90.22 ± 31.26psi), in backflow (p<0.0001). On the other hand, the Patient-set® with broken FDs didn\'t show failure in NRVs functionality, through the lack of air bubbles release. Moreover, NRVs showed broken FDs, but the other structures remained whole. The air columns can be compressed and move through Patient-set® with whole and broken FDs. Besides, the longest diffusion distance of crystal violet was 30% (6cm) of connector length (20cm) of Patient-set®. Furthermore, the measure technique by spectrophotometer (absorbance) was more sensitive than by visual inspection for this purpose. Patientset® NRVs showed efficacy as barrier to bacterial contamination (Methicillin-resistant Staphylococcus aureus, 10psi for 2h30min). Moreover, a SOP was elaborated and validated for Patient-set® utilization and handling, aiming at biosafety in clinical practice, contamination and infection risk controls in infusion systems in radiology as original recommendation to be made available to all professionals in the field. In conclusion, the biosafety depends on various physical, functionality, and microbiological aspects of NRVs coupled with proper practical clinical performance. Besides, further researches are needed to elucidate future questionings about NRVs safe use
55

Análise do comportamento dinâmico da ligação formada por barras de aço coladas para tabuleiros mistos de madeira e concreto para pontes / Analysis of the dynamic behavior of the connectors formed by bonded-in steel rods for log-concrete composite deck bridges

Julio Cesar Molina 26 May 2008 (has links)
Neste trabalho avaliou-se o comportamento estrutural do sistema misto madeira-concreto para tabuleiros de pontes, com ênfase na análise dinâmica dos conectores de cisalhamento, para dois tipos de conectores: \"vertical\" e em \"X\". Foram efetuadas duas principais abordagens, numérica e experimental, além de um amplo levantamento teórico sobre o tema com base na literatura disponível. Os ensaios experimentais foram realizados em corpos-de-prova de madeira como também em corpos-de-prova mistos e vigas mistas de madeira-concreto. Todos os corpos-de-prova e vigas foram submetidos a solicitações estáticas e dinâmicas, considerando-se os diversos materiais envolvidos na ligação. A análise numérica dos sistemas mistos foi efetuada com base no método dos elementos finitos, a partir da utilização do software ANSYS. Os resultados experimentais mostraram que ambos os sistemas de conexão perderam efetivamente rigidez para um total de 1 x \'10 POT.6\' ciclos de carga aplicados, sendo a maior parcela desta perda verificada para os ciclos iniciais. Além disso, o sistema de conexão \"vertical\" apresentou maior facilidade de execução quando comparado com o sistema de conexão em \"X\". A partir dos resultados numéricos constatou-se que a perda de rigidez ocorreu devido ao acúmulo do dano localizado nos materiais, nas regiões dos conectores. Os resultados numéricos mostraram uma boa concordância com os resultados experimentais. Para finalizar, foram propostos os valores dos níveis máximos e mínimos de carga cíclica, como também da frequência de excitação a serem utilizados nos ensaios dinâmicos para a verificação da rigidez dos sistemas mistos de conexão. / In this work was evaluated the structural behavior of log-concrete composite deck bridge system, with emphasis in the dynamic analysis of the shear connectors using two types of connectors: \"vertical\" and \"X\". Two main approaches were considered, numeric and experimental, besides a wide theoretical study about the theme with base in the available literature. The experimental studies were accomplished in specimens of wood, wood-concrete specimens and wood-concrete beams. All of the specimens and beams were subjected to static and dynamic loads considering several materials in the composed connection system. The numeric analyze of the composed systems was made with base in the method of the finite elements using the software ANSYS. The experimental results showed that both connection systems reduced stiffness really for 1 x \'10 POT.6\' applied load cycles, and the largest portion of this reduction happens in the initial cycles. Besides, the system of \"vertical\" connection presented larger execution easiness when compared with the system \"X\" connection. The numeric results showed that the reduced stiffness of the connection systems happened due to the accumulation of the located damage of the materials in the areas of the connectors. The numeric and experimental results comparison showed a good agreement. It was proposed values for the maximum and minimum levels of cyclical load, as well as for the frequency to be used in the dynamic tests for the verification of the reduced stiffness of the composite system of connection.
56

Viga mista de aço e concreto constituída por perfil formado a frio preenchido / Composite steel and concrete beam constituted by filled cold-formed steel section

Igor Avelar Chaves 20 January 2009 (has links)
As vigas mistas de aço e concreto têm sido amplamente empregadas em edifícios e pontes, havendo ampla investigação teórica e experimental a respeito da utilização de perfis laminados e soldados e conectores de cisalhamento compatíveis com esses perfis, como por exemplo, o conector tipo pino com cabeça (stud bolt) e perfil U laminado. No âmbito dos perfis formados a frio, a utilização do sistema misto ainda é incipiente, necessitando de investigações mais aprofundadas a respeito do comportamento estrutural e a adequação dos modelos de cálculo adotados para vigas mistas em perfis laminados e soldados. No Brasil, a ampla disponibilidade de aços planos tem impulsionado o emprego do sistema misto constituído por perfis formados a frio em edifícios de pequeno porte, porém, mediante concepções clássicas, o que não conduz a um aproveitamento mais racional do sistema. Neste trabalho foi investigado um sistema não-convencional de vigas mistas em perfil cartola leve preenchido com concreto, cuja conexão com a laje foi feita mediante duas soluções: conectores do tipo alça em barra chata soldados ao perfil e conectores do tipo alça em barra redonda soldados ao perfil. Foi feita avaliação do comportamento estrutural da conexão aço-concreto, via ensaios de cisalhamento direto (push-out tests), e ensaios em vigas mistas simplesmente apoiadas para avaliação da região de momento fletor positivo. Os conectores de cisalhamento apresentaram ductilidade e resistência compatíveis com as vigas mistas analisadas, e as respostas de rigidez e resistência à flexão para uma condição de interação completa comprovam que a hipótese de plastificação total da seção descreve com precisão o comportamento estrutural do sistema proposto. / The composite steel and concrete beams have been largely applied in buildings and bridges constructions, having also a large amount of theoretical and experimental investigations about the use of hot-rolled and welded shapes and shear connectors that are compatible with these members, as for an example, the stud bolt and channel connectors. In the cold-formed steel sections scope, the use of a composite steel and concrete solution is still premature, what makes necessary a higher degree of a structural behavior investigation and the adequacy of the theoretical solutions proposed, also for the composite steel and concrete hot-rolled and welded shapes. In Brazil, the high availability of steel sheets has pushed the employee of the composite system of cold-formed steel in small and mid-height buildings, however, because of classical conceptions, it doesn\'t lead too a more rational use of the system. It was investigated in this work a non-conventional lightweight composite system formed by hat-shaped beams filled with concrete, witch connection with the slab was done by means of two solutions: arc-shaped connectors in at bars welded too the section and arc-shaped connectors in round bars welded too the section. An analysis was conducted for evaluation of the structural behavior in the steel and concrete interface by push-out tests, and tests in simple two points supported beams for evaluation of the bending strength. The shear connectors showed ductility and resistance compatible with the analyzed composite beams and the stiffness and bending resistance responses for the given condition of full interaction showed that the full section plastification consideration describes with precision the structural behavior of the proposed system.
57

Estudos e aplicações de barras de aço coladas, como conectores em lajes mistas de madeira e concreto para tabuleiros de pontes / Studies and applications of glued-in steel rods on shear connectors in mixed wood-concrete deck bridges

Julio César Pigozzo 06 December 2004 (has links)
As pontes tradicionais de madeira no Brasil, nem sempre atingem as condições plenamente satisfatórias em estradas vicinais, exigem manutenção contínua e a maioria não está adequada ao tráfego pesado usual. As pontes mistas de madeira e concreto destacam-se como alternativa econômica apresenta grande resistência e rigidez além de exigir baixa manutenção. Neste trabalho os estudos dos tabuleiros mistos de madeira e concreto para pontes desenvolveram-se em três fases: estudo da ancoragem de barras de aço coladas em peças estruturais de madeira; estudo dos conectores de cisalhamento formados por barras de aço coladas na madeira em corpos-de-prova mistos de madeira e concreto e, estudos; construções e análises de protótipos de tabuleiros mistos de madeira e concreto. Nos estudos de ancoragens, as barras de aço com superfície deformada, do tipo CA-50 com tensão de escoamento 'F IND.Y,K' = 500 MPa, foram coladas em furos com diâmetros maiores, inclinadas de '0, 45 e 90 GRAUS' em relação às fibras das madeiras. Utilizaram-se quatro tipos de resina epóxi e uma poliuretana, considerando as principais variáveis que influenciam na resistência de ancoragem. Os corpos-de-prova foram construídos com amostragens de madeiras de: Eucalyptus citriodora (&#961; 12% = 1000 kg/'M POT.3') e Pinus oocarpa shiede (&#961; 12% = 550 kg/'M POT.3'). Os testes de ancoragem apresentam as estimativas das resistências médias obtidas por meio de análise de regressão múltipla e as resistências características, obtidas pelo limite inferior do intervalo de confiança a 90%. Nos estudos dos conectores de cisalhamento utilizaram-se corpos-de-prova mistos, do tipo push out, executados com madeira roliça natural de Eucalyptus citriodora tratada com CCA e concreto armado de média resistência. Os conectores de cisalhamento, em três variações, foram executados com barras de aço do tipo CA-50 ancoradas na madeira, com a resina epóxi SIKADUR 32 fluido e inclinados de '45 GRAUS' em relação às fibras, os resultados apresentam, as resistências últimas médias, as resistências características; os valores médios e os valores característicos dos módulos de deslizamento da conexão. Nos estudos, projetos e execuções de dois tabuleiros mistos, de madeira e concreto, utilizaram-se toras de Eucalyptus citriodora tratadas com CCA, concreto armado de média resistência e conectores de barras de aço coladas com resina epóxi no formato X. Análises estáticas foram realizadas submetendo os tabuleiros às provas de carga, utilizando caminhões. Os deslocamentos na linha central transversal foram medidos e comparados com os valores teóricos calculados usando um modelo de cálculo que considera o tabuleiro misto como uma placa ortotrópica equivalente. Os conectores apresentaram alta resistência; alta rigidez e modo de ruptura uniforme. Os tabuleiros mistos de madeira e concreto apresentaram muito bom desempenho, confirmaram-se as hipóteses fundamentais e o modelo de cálculo proposto. / The traditional timber bridges in secondary roads in Brazil not always meet the requirements of quality, but they also demand continuing maintenance and adequacy to heavy traffic. The mixed wood-concrete deck bridges arise as a viable alternative, because of its low construction cost, low maintenance and its high strength and stiffness. In this thesis the mixed wood concrete deck bridge studies was showed in three phases: the experimental pull out strength results of bonded-in steel rods in wood beams studs; the experimental analysis on shear connectors in mixed wood concrete specimens using bonded-in steel bars and, designs; constructions and statistics tests on log-concrete composed deck bridges was presented too. In the anchorage studies the deformed and reinforced CA-50 steel bars, with the minimum yield strength of 500 Mpa, were bonded in holes drilled at angles of '0, 45 and 90 DEGREES' between the rods and on the direction of grain. Four types of epoxy and one polyurethane adhesive were used regarding the influence of the most significant variables. The specimens were made using Eucalyptus citriodora (&#961; 12% = 1000 kg/'M POT.3') and Pinus oocarpa shiede (&#961; 12% = 550 kg/'M POT.3') beams. The pull out tests presents the median strength results estimated by multiple regression analysis and the characteristics response estimated by the lower range in 90% of the confidence interval. In the shear connections studies were carried using specimens of push out tests type made of logs of Eucalyptus citriodora treated with CCA and medium strength reinforced concrete. The shear connectors, in three shapes, were made with CA-50 steel bars bonded-in wood with SIKADUR 32 fluid epoxi resin, with '45 DEGREES' angles between the rods and on the direction of grain. The results presents the ultimate limit strength median, the characteristics strength, the slip modulus medians and the characteristics slip modulus. In the studies, designs and executions of two mixed wood-concrete decks bridge were used made of logs of Eucalyptus citriodora treated with CCA, medium strength reinforced concrete, and bonded-in steel CA-50 rods, as shear connectors in X format. Same static loads test on the bridges was carried out using a truck. Deflections in the medium span transversal directions were measured and analytically predicted using an equivalent orthotropic plate model. The shear connectors showed high ultimate strength and stiffness and, uniforms failure mode. The results showed a very good performance to the composed log-concrete deck bridges, it confirms the fundamental hypothesis and calculus model suggested.
58

Análise experimental de pilares de concreto armado submetidos à flexo-compressão, reforçados com concreto auto-adensável e conectores / Experimental analysis of reinforced concrete columns under flexural compression, strengthened with self-compacting concrete and connectors

NASCIMENTO, Poliana Paula 11 September 2009 (has links)
Made available in DSpace on 2014-07-29T15:03:39Z (GMT). No. of bitstreams: 1 dissertacao poliana paula nascimento.pdf: 3745799 bytes, checksum: 3d668e197266750a56c400714f13762a (MD5) Previous issue date: 2009-09-11 / Many problems involving cases of ruins of buildings, bridges, etc., specifically ruin of columns, which are among the most important links in the whole structure, due to project flaw, bad execution or even for the evolution and changing habits. Therefore it has been of fundamental importance researches on the experimental behavior of structures. When conducting a strengthening column using dry with increased self-compacting concrete, it has the drawback of a sudden rupture by peeling the reinforcement. For this, there is a need to study the area of adhesion between substrate and to strengthen and create a way of preparation of this interface area so that the column increases may come into ruin in a ductile flexural as well as in a monolithic column. Thus, it s been developed an experimental study in the School of Civil Engineering, Federal University of Goias, based on analysis of the breaking loads, lateral displacements and deformations of the column of materials for different ways of preparing the surface of the column to be strengthened. The experimental phase of this work was based on testing of nine reinforced concrete columns, which are tested under flexural compression, with eccentricity of 60 mm. Two columns were used as reference columns, one with the original dimensions of the column and the other monolithic concreted in the thickness of a sin reinforced the others received a layer of 35 mm thick concrete selfcompacting in the compressed face. For preparation of the interchange between the two materials, it was proceeded with the scarification and the realization of grooves along this surface, where inserted connectors attached to transverse reinforcement of the columns, varying the position and quantity of the same. It can be concluded that not only quantity, but mainly the location of connectors used in the connection between the substrate and reinforcement, is essential for a good result of resistance and rupture mode. Must be observed a minimum spacing between the connectors strengthening to ensure a more monolithic unit, enabling a ductile rupture occurred as the reference column / Muitos são os problemas envolvendo casos de ruína de edifícios, pontes etc, especificamente ruína de pilares, que são uns dos elos mais importantes do conjunto estrutural, por falha de projeto, de execução ou ainda, pela evolução e alteração de hábitos. Por isso tem sido de fundamental importância as pesquisas que abordam o comportamento experimental das estruturas. Ao se realizar um reforço de pilar utilizando-se aumento de seção com concreto auto-adensável, tem-se o inconveniente de uma ruptura brusca por desplacamento do reforço. Para tanto, verifica-se a necessidade de estudar a zona de aderência entre substrato e reforço e criar um modo de preparo desta zona de interface de modo que o pilar reforçado possa entrar em ruína de forma dúctil por flexão, assim como acontece em um pilar monolítico. Assim, desenvolveu-se um estudo experimental na Escola de Engenharia Civil da Universidade Federal de Goiás, baseado na análise de cargas de ruptura, deslocamentos laterais dos pilares e deformações dos materiais para diferentes formas de preparo da superfície do pilar a ser reforçado.A etapa experimental deste trabalho baseou-se no ensaio de nove pilares de concreto armado, sendo estes ensaiados à flexo-compressão reta, com excentricidade de 60 mm. Dois pilares foram usados como pilares de referência, sendo um com as dimensões originais do pilar e o outro monolítico concretado na espessura de um peça reforçada, os demais receberam uma camada de 35 mm de espessura de concreto auto-adensável na face comprimida. Para preparo da zona de interface entre os dois materiais, procedeu-se com a escarificação e a realização de sulcos ao longo desta superfície, onde foram inseridos conectores ligados a armadura transversal do pilar, variando-se a posição e a quantidade dos mesmos. Pode-se concluir que não só a quantidade, mas principalmente, a localização dos conectores utilizados na ligação entre substrato e reforço, são imprescindíveis para um bom resultado de resistência e modo de ruptura. Sendo necessário respeitar um espaçamento mínimo entre os conectores do reforço para se garantir um trabalho mais monolítico da peça, possibilitando uma ruptura dúctil como a ocorrida nos pilares de referência
59

Vigas mistas com laje de concreto e perfis laminados tipo I: análise comparativa do comportamento estrutural entre conectores / Composite beams with reinforced concrete slab and rolled I beam: comparative analysis of the structural behavior of connectors

RIBEIRO NETO, Juliano Geraldo 19 March 2010 (has links)
Made available in DSpace on 2014-07-29T15:03:41Z (GMT). No. of bitstreams: 1 Juliano Geraldo Ribeiro Neto.pdf: 2086855 bytes, checksum: 3b65b93d36838091f2c1204a03908f1c (MD5) Previous issue date: 2010-03-19 / Among the many structural and building systems, it could be highlighted a system that is a mix of steel-concrete that allows the application of their structural and building advantages as whole. When dealing with metal structures, it was noticed some changes regarding the standards of the involved material due to its lack of availability; such measures do not always follow satisfactory structural procedures. This research aims to develop a comparative study about the technical behavior of mixed steel-concrete from three different types of shear connectors (U, U and L cold formed laminated), analyzing their connectors structural behavior when associated with steel beams (Type I rolled and concrete slab). There were three direct shear tests for each type of connector, resulting in a total of nine pieces, and six trials (simply supported composite beams) to evaluate the positive bending moment region. The results indicated that the direct shear behavior between the types of connectors had important and different outcomes; however, they didn t affect significantly the average resistance of the bending mixed beams. Such beams showed considerable results regarding their deflection and deformation performance due to their connectors stiffness. / Dentre os diversos sistemas estruturais e construtivos existentes, destacam-se os sistemas formados por elementos mistos aço-concreto, cuja combinação de perfis de aço e concreto visa aproveitar as vantagens de cada material, tanto em termos estruturais como construtivos. Um fato corriqueiro que pode ser observado na execução de obras metálicas é a substituição de perfis especificados em projeto por outros equivalentes. Essa substituição, muitas vezes motivada pela falta do material especificado, nem sempre atende a uma equivalência de comportamento estrutural satisfatória. Neste trabalho é abordado um estudo comparativo do comportamento estrutural de vigas com seção mista aço-concreto, para três diferentes tipos de conectores de cisalhamento em perfil U laminado, U e L formados a frio. O objetivo é estudar o comportamento estrutural desses conectores associados a vigas metálicas em perfil I laminado e laje de concreto. Para cada tipo de conector foram realizados três ensaios de cisalhamento direto, resultando num total de nove peças, além de seis ensaios em vigas mistas simplesmente apoiadas para avaliação da região de momento fletor positivo. Os resultados obtidos indicaram que o comportamento ao cisalhamento direto entre os diferentes tipos de conectores apresentam significativa diferença, entretanto não influenciaram significativamente na resistência média das vigas mistas à flexão. Estas porém, apresentaram diferenças consideráveis de deflexões e deformações em virtude das diferenças de rigidez dos conectores.
60

Uma abordagem baseada em ontologias e conectores para a integração semântica de ferramentas de análise de expressão gênica / An Approach Based on Ontologies and Connectors for Semantic Integration of Gene Expression Analysis Tools

Flavia Akemi Miyazaki 15 December 2011 (has links)
As pesquisas em biologia molecular têm produzido uma grande quantidade de dados, os quais embutem informações sobre diferentes fenômenos biológicos. Neste sentido, a bioinformática se destaca como uma área de pesquisa multidisciplinar que visa, principalmente, o desenvolvimento de ferramentas (sistemas) computacionais para auxiliar na descoberta de conhecimento a partir de dados biológicos. Dentro da bioinformática, a área de genômica funcional procura estudar as funções gênicas através da medição simultânea e em larga escala dos níveis de expressão gênica de um genoma. Diferentes ferramentas são utilizadas no processo de análise de expressão gênica, cada qual provê suporte a uma atividade de análise específica. Embora alguns ambientes de descoberta de conhecimento ofereçam suporte integrado a este processo de análise e exploração de dados, a maior parte das ferramentas de análise é desenvolvida independentemente de outras ferramentas e ambientes de descoberta de conhecimento. Este cenário representa um desafio para biologistas que precisam combinar e integrar diferentes ferramentas, muitas vezes de forma ad hoc, custosa e sujeita a erros. Modelos conceituais, tais como ontologias, têm contribuído para o sucesso do desenvolvimento de sistemas computacionais em diferentes domínios de aplicação. O desenvolvimento de tais modelos tem por objetivo representar corretamente, em alto nível de abstração, conceitos e situações pertinentes a um dado domínio de interesse. Esta representação abstrata facilita não apenas o entendimento de um dado domínio, mas também serve como base para o processo de desenvolvimento do sistema como um todo. O objetivo deste trabalho é investigar o desenvolvimento e o uso de modelos conceituais em geral e ontologias em particular, na integração de ferramentas na área de análise de expressão gênica. De forma específica, este trabalho tem por objetivo propor uma abordagem para a integração semântica de ferramentas de análise de expressão gênica a partir do uso de conectores e de uma ontologia de domínio. Essa abordagem foi aplicada no desenvolvimento de estudos de caso envolvendo a criação de diferentes ambientes integrados para a análise de expressão gênica e mostrou-se eficaz. / Molecular biology researches are increasingly producing large amounts of data regarding underlying biological phenomena. Bioinformatics is a multidisciplinary research field whose main objective is the development of theories and information systems to help the process of knowledge discovery from biological data. Functional genomics is a field of study bioinformatics concerned with the study of gene function through parallel and large scale expression measurements of a genome. A variety of software tools are usually combined and used in a knowledge discovery process, each providing support for a specific data analysis task. Although some tools are already provided as part of an integrated knowledge discovery environment, most of them are developed independently of other software tools and knowledge discovery environments. This scenario poses a problem and a challenge for biologists that need to combine and integrate different tools in an ad hoc, time consuming and error prone process. Conceptual models, such as ontologies, have contributed to the successful development of information systems in different application domains. The development of such models aims at creating a clear and precise description of the elements of a given domain at a high abstraction level. This abstract and high level description not only promotes a shared understanding of the domain, but also serves as basis for the development process of supporting applications in the domain. This work aims at investigating the development and use of conceptual models in general and ontologies in particular to support the integration of gene expression data analysis systems. Specifically, this work proposes an approach for the semantic integration of gene expression analysis tools using connectors and a domain ontology. This approach was applied in the development of a number of case studies aiming at creating integrated environments for gene expression analysis and proved its effectiveness.

Page generated in 0.0449 seconds