• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 48
  • 3
  • 2
  • Tagged with
  • 55
  • 33
  • 29
  • 27
  • 23
  • 23
  • 23
  • 20
  • 19
  • 18
  • 17
  • 16
  • 14
  • 14
  • 13
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Evaluación estructural de reservorios apoyados de concreto armado en Lima Metropolitana considerando la norma ACI 350-06 y las normativas peruanas / Structural assessment of round ground concrete water tanks in Lima Metropolitana considering the ACI 350.3-06 standard and Peruvian regulations

Diaz Calderon, Alvaro Emilio, Meniz Ventocilla, Brigitte Carolina 05 April 2019 (has links)
En la presente tesis se ha desarrollado la evaluación estructural de cinco reservorios circulares del tipo apoyado, construidos entre los años 1977 y 1997, ubicados en zonas de alto riesgo sísmico en Lima Metropolitana y ubicados en suelos medianamente rígidos, con el objetivo de evidenciar si estas estructuras continúan conservando un diseño sísmico adecuado en base a los requerimientos sísmicos actuales, y por ende si serán capaces de resistir un evento sísmico severo y continuar con el servicio. Para poder modelar y determinar la respuesta de los se reservorios se empleó el modelo equivalente de Housner, obteniendo así la masa impulsiva y convectiva, modelado en el programa SAP2000 con ayuda de las normas ACI 350.3-06 y E.030. En cuanto a la determinación de las fuerzas resistentes, para poder realizar la evaluación estructural correspondiente, se utilizó la norma peruana E.060-2009 Concreto Armado, con la cual se obtuvo dichas fuerzas y se realizaron las verificaciones estructurales. Con respecto a los resultados de las verificaciones realizadas, se observó que los reservorios en estudio no mantienen un diseño estructural adecuado en cuanto a las solicitaciones sísmicas actuales. Estas deficiencias se plasman en déficit de refuerzo horizontal por corte en muros, cuantía mínima vertical por corte en muros, refuerzo en la base del muro por momento tangencial, armadura requerida en la viga collarín, y refuerzo en el extremo de la cúpula por tracción radial; por lo que estas estructuras, ante la presencia de un evento sísmico severo, se encuentran expuestas a presentar fallas estructurales. / In the present thesis has been carried out the structural assessment of five round ground concrete tanks, built between 1977 and 1997, and located in high seismic risk areas in Lima Metropolitana in moderately rigid soils, with the objective of demonstrating if these structures still preserve an adequate structural design base on the current standards and consequently, if they will be able to withstand a severe seismic event and, hence, continue with their service. In order to model and determine the response of the tanks, the Housner’s rigid equivalent model was used, obtaining this way the impulsive and convective masses, which were modeled in the software SAP2000 with the ACI 350.3-06 standard and the E.030 Peruvian standard. Regarding on the determination of the resistant forces, in order to carry out the corresponding structural evaluation, the Peruvian standard “Concreto Armado E.060” was utilized. With regard to the results of the verifications carried out, it was observed that the reservoirs under study do not maintain an adequate structural design in terms of the current seismic solicitations. These deficiencies are reflected in horizontal reinforcement deficit by shear force on the walls, minimum amount of vertical rebar by shear on the walls, reinforcement in the base of the wall by tangential bending moment, rebar required in the beam by radial tensile force, and rebar in the end of the dome by radial traction; so these structures, in the presence of a severe seismic event, are exposed to structural failures. / Tesis
52

Análise experimental do efeito da geometria da seção transversal e do desempenho de fluidos de reduzido GWP na ebulição convectiva em canais de dimensões reduzidas / Experimental analysis of the cross-sectional geometry effect and low GWP refrigerants performance during convective boiling inside micro-scale channels

Sempértegui Tapia, Daniel Felipe 23 March 2016 (has links)
A presente tese trata da análise experimental do efeito da geometria da seção transversal do canal e do desempenho de refrigerantes de reduzido GWP (Global Warming Potential) durante a ebulição convectiva em canais de reduzidas dimensões. A tese inclui ainda um estudo extenso e crítico da literatura sobre métodos de previsão da perda de pressão e do coeficiente de transferência de calor, e sobre estudos experimentais em canais não-circulares e de refrigerantes com reduzido GWP na ebulição convectiva em canais de dimensões reduzidas. Resultados para o coeficiente de transferência de calor e perda de pressão durante a ebulição convectiva foram obtidos para canais com geometrias de seção circular, quadrada e triangular para o refrigerante R134a. Nos testes utilizou-se canais com perímetros internos similares obtidos a partir da conformação de um tubo com diâmetro interno igual a 1,1 mm. No caso do canal circular, dados foram também levantados para os HFOs R1234ze(E) e R1234yf e o hidrocarboneto R600a, fluidos com reduzido GWP. Ensaios foram executados para amplas faixas de fluxos de calor e velocidades mássicas, temperaturas de saturação de 31 e 41°C e títulos de vapor entre 0 e 0,95. Aspectos relacionados aos efeitos da geometria e do fluido refrigerante foram minuciosamente investigados através da análise paramétrica dos resultados. Com base na comparação do banco de dados coletado com os métodos de previsão disponíveis na literatura, constatou-se que estes proporcionam previsões satisfatórias apenas para condições experimentais especificas. Portanto, novos métodos de previsão da perda de pressão e do coeficiente de transferência de calor foram desenvolvidos com base nos dados levantados no presente estudo. Os métodos propostos preveem satisfatoriamente o banco de dados do presente estudo e resultados independentes disponíveis na literatura. Adicionalmente, com base nos resultados levantados, verificou-se que dissipadores de calor baseados em multi-microcanais com canais de seção triangular apresentam desempenho superior comparados a dissipadores com canais quadrados e circulares. / The present thesis concerns an experimental study on the effects of cross-sectional geometry and low GWP refrigerants on the thermal-hydraulic performance for convective boiling inside micro-scale channels. Experimental results for heat transfer coefficient and pressure drop gradient during convective boiling were obtained for circular, square and triangular channels for the fluid R134a. The evaluated channels present the same external perimeter and equivalent diameters of 1.1, 0.977 and 0.835 mm, respectively. In the case of the circular geometry, experimental results were also acquired for the HFOs R1234ze(E) and R1234yf and the hydrocarbon R600a (isobutane), which are fluids with low GWP and null ODP. Experiments were performed for a wide range of heat fluxes and mass velocities, saturation temperatures of 31 and 41°C and vapor qualities up to 0.95. The experimental data were carefully analyzed and discussed based on a parametrical analysis focusing on the effect of the cross-sectional geometry and the working fluid. Subsequently, the experimental data were compared against the most quoted predictive methods from literature. In general, it was verified that none of the predictive methods were able to accurately capture the experimental trends of the overall database. So, new predictive methods for the pressure drop and heat transfer coefficient were developed based on the broad database obtained in the present study. The proposed methods provided satisfactory results not only for the experimental database used for its development, but also for independent databases collected in the literature. Additionally, based on the data obtained in the present study and a performance analysis taken into account pressure drop, heat transfer coefficient and the channel packing factor, triangular cross sectional geometry is recommended for heat sinks.
53

Dynamics of hydrothermal plumes in Lake Banyoles

Soler i Ortega, Marianna 13 June 2008 (has links)
Aquesta tesi permet adquirir una millor comprensió de la dinàmica dels plomalls hidrotèrmics en l'estany de Banyoles i correlacionar la meteorologia amb els processos de fluïdització que s'hi produeixen. S'han trobat els patrons atmosfèrics que generen els esdeveniments de les fluïditzacions així com la seva freqüència. Això és crucial per a determinar la qualitat de l'aigua de l'estany. S'han trobat inhomogeneïtats espacials tant en el plomall crònic que es desenvolupa en la cubeta B1, com en el plomall episòdic de la cubeta B2. S'ha caracteritzat l'estructura del plomall generat a la cubeta B2 i s'ha comparat amb el desenvolupat a la cubeta B1. Finalment, s'han realitzat simulacions numèriques mitjançant un model numèric: MIT General Circulation Model, en el qual s'ha hagut de fer canvis en les condicions de contorn per a situar la font convectiva al fons de la columna d'aigua. Les simulacions s'han comparat amb els resultats experimentals trobats mitjançant campanyes. / The aim of this thesis is to acquire a better understanding of the dynamics of the hydrothermal plumes in the lake and to gain more insight into the interrelationship between meteorology and fluidization. They have been found the atmospheric patterns that generate the fluidization events, as well as their frequency. This is crucial to determining the water quality of Lake Banyoles. They have been found spatial inhomogeneities of the chronic thermal plume found in B1 and of the episodic thermal plume in B2. The structure of thermal plume in B2 has been characterized and compared to the plume developed in B1. Finally, it has been used a numerical model: MIT General Circulation Model. It has been necessary to modify the boundary conditions moving the buoyancy source from the top of the water surface to the bottom. Results have been compared to experimental data undertaken from the field campaigns.
54

Descrição da secagem convectiva de grãos de milho através de modelos difusivos.

BORGES, Fabrício Batista. 13 June 2018 (has links)
Submitted by Emanuel Varela Cardoso (emanuel.varela@ufcg.edu.br) on 2018-06-13T20:31:59Z No. of bitstreams: 1 FABRÍCIO BATISTA BORGES – TESE (PPGEP) 2016.pdf: 4027586 bytes, checksum: c02ca04ae0983633d70b155cc190bf48 (MD5) / Made available in DSpace on 2018-06-13T20:31:59Z (GMT). No. of bitstreams: 1 FABRÍCIO BATISTA BORGES – TESE (PPGEP) 2016.pdf: 4027586 bytes, checksum: c02ca04ae0983633d70b155cc190bf48 (MD5) Previous issue date: 2016-09-23 / Objetiva-se com este trabalho realizar estudos usando as soluções analítica e numérica da equação de difusão para descrever a secagem em camada fina de grãos de milho nas temperaturas de 45, 55, 65 e 75 ºC, os quais têm uma forma que pode ser aproximada a de um paralelepípedo. Foram utilizadas ferramentas numéricas e analíticas para o estudo dos fenômenos difusivos envolvendo as três dimensões geométricas dos grãos mencionados. Para a solução numérica proposta, a equação de difusão tridimensional foi discretizada utilizando os métodos dos volumes finitos, com uma formulação totalmente implícita, fazendo uso das coordenadas cartesianas. Com a finalidade de estabelecer a correta condição de contorno na descrição da cinética de secagem dos grãos de milho, foram utilizados três softwares para a determinação dos parâmetros de processo a partir dos dados experimentais via otimização. O primeiro software usado para simular a cinética de secagem do milho foi “Prescribed Adsorption – Desorption” V.2.2, que utiliza a solução analítica da equação de difusão empregando a condição de contorno do primeiro tipo. O segundo software utilizado foi o “Convective Adsorption – Desorption” V. 2.4. Este simula a cinética de secagem de produtos usando a solução analítica da equação de difusão empregando a condição de contorno do terceiro tipo. Já o terceiro software usado na otimização foi o “LS Optimizer” V.2.1, que determina os parâmetros de uma equação diferencial usando o método dos mínimos quadrados na solução numérica da equação de difusão com a condição de contorno do terceiro tipo. Esses dois últimos geraram resultados coerentes e consistentes em todas as etapas efetuadas durante os testes. Pode-se concluir que o segundo e o terceiro modelos propostos para analisar os dados da pesquisa foram coerentes e equivalentes, e os resultados obtidos foram satisfatórios. Assim, a condição de contorno do terceiro tipo foi usada para a solução numérica tridimensional da equação de difusão em coordenadas cartesianas. Testes de validação indicaram que a solução numérica desenvolvida apresenta resultados coerentes com aqueles esperados. / The objective with this essay is to carry out studies using analytical and numerical solutions of the diffusion equation to describe the drying of thin layer of corn grains at temperatures of 45, 55, 65 and 75 ° C, which have a shape that can be approximated for a parallelepiped. Numerical and analytical tools were used for the study of the diffusive phenomena involving the three geometric dimensions of the mentioned grains. For the numerical solution proposed, the three dimensional diffusion equation was discretized using the finite volume method with a fully implicit formulation using the cartesian coordinates. In order to establish the right boundary condition in the description of the corn grain drying kinetics, three software were used for the determination of the process parameters from the experimental data using optimization. The first software used to simulate corn drying kinetics was "Prescribed Adsorption - Desorption" V.2.2, which uses the analytical solution of the diffusion equation using the boundary condition of the first type. The second software used was "Convective Adsorption - Desorption" V. 2.4. This one simulates the kinetics of drying products using the analytical solution of the diffusion equation using the boundary condition of the third kind. The third software used in the optimization was the "LS Optimizer" V.2.1 which determines the parameters of a differential equation using the method of least squares in the numerical solution of the diffusion equation using the boundary condition of the third kind.The latter two have generated coherent and consistent results in all steps performed during testing. It can be concluded that the second and third proposed models to analyze the survey data were consistent and equivalent and the results were satisfactory. Thus, the boundary condition of the third kind was used for three -dimensional numerical solution of the diffusion equation in cartesian coordinates. Validation tests indicated that the developed numerical solution provides coherent results with t hose expected.
55

Análise experimental do efeito da geometria da seção transversal e do desempenho de fluidos de reduzido GWP na ebulição convectiva em canais de dimensões reduzidas / Experimental analysis of the cross-sectional geometry effect and low GWP refrigerants performance during convective boiling inside micro-scale channels

Daniel Felipe Sempértegui Tapia 23 March 2016 (has links)
A presente tese trata da análise experimental do efeito da geometria da seção transversal do canal e do desempenho de refrigerantes de reduzido GWP (Global Warming Potential) durante a ebulição convectiva em canais de reduzidas dimensões. A tese inclui ainda um estudo extenso e crítico da literatura sobre métodos de previsão da perda de pressão e do coeficiente de transferência de calor, e sobre estudos experimentais em canais não-circulares e de refrigerantes com reduzido GWP na ebulição convectiva em canais de dimensões reduzidas. Resultados para o coeficiente de transferência de calor e perda de pressão durante a ebulição convectiva foram obtidos para canais com geometrias de seção circular, quadrada e triangular para o refrigerante R134a. Nos testes utilizou-se canais com perímetros internos similares obtidos a partir da conformação de um tubo com diâmetro interno igual a 1,1 mm. No caso do canal circular, dados foram também levantados para os HFOs R1234ze(E) e R1234yf e o hidrocarboneto R600a, fluidos com reduzido GWP. Ensaios foram executados para amplas faixas de fluxos de calor e velocidades mássicas, temperaturas de saturação de 31 e 41°C e títulos de vapor entre 0 e 0,95. Aspectos relacionados aos efeitos da geometria e do fluido refrigerante foram minuciosamente investigados através da análise paramétrica dos resultados. Com base na comparação do banco de dados coletado com os métodos de previsão disponíveis na literatura, constatou-se que estes proporcionam previsões satisfatórias apenas para condições experimentais especificas. Portanto, novos métodos de previsão da perda de pressão e do coeficiente de transferência de calor foram desenvolvidos com base nos dados levantados no presente estudo. Os métodos propostos preveem satisfatoriamente o banco de dados do presente estudo e resultados independentes disponíveis na literatura. Adicionalmente, com base nos resultados levantados, verificou-se que dissipadores de calor baseados em multi-microcanais com canais de seção triangular apresentam desempenho superior comparados a dissipadores com canais quadrados e circulares. / The present thesis concerns an experimental study on the effects of cross-sectional geometry and low GWP refrigerants on the thermal-hydraulic performance for convective boiling inside micro-scale channels. Experimental results for heat transfer coefficient and pressure drop gradient during convective boiling were obtained for circular, square and triangular channels for the fluid R134a. The evaluated channels present the same external perimeter and equivalent diameters of 1.1, 0.977 and 0.835 mm, respectively. In the case of the circular geometry, experimental results were also acquired for the HFOs R1234ze(E) and R1234yf and the hydrocarbon R600a (isobutane), which are fluids with low GWP and null ODP. Experiments were performed for a wide range of heat fluxes and mass velocities, saturation temperatures of 31 and 41°C and vapor qualities up to 0.95. The experimental data were carefully analyzed and discussed based on a parametrical analysis focusing on the effect of the cross-sectional geometry and the working fluid. Subsequently, the experimental data were compared against the most quoted predictive methods from literature. In general, it was verified that none of the predictive methods were able to accurately capture the experimental trends of the overall database. So, new predictive methods for the pressure drop and heat transfer coefficient were developed based on the broad database obtained in the present study. The proposed methods provided satisfactory results not only for the experimental database used for its development, but also for independent databases collected in the literature. Additionally, based on the data obtained in the present study and a performance analysis taken into account pressure drop, heat transfer coefficient and the channel packing factor, triangular cross sectional geometry is recommended for heat sinks.

Page generated in 0.07 seconds