• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Energy Losses Study on District Cooling Pipes : Steady-state Modeling and Simulation

Calance, Marius Alexandru January 2014 (has links)
Distributionsförluster är en viktig faktor i fjärrenergisystem. Genom att optimera förluster i sådana system, kan både ekonomiska och miljömässiga aspekter uppfyllas. Tyvärr finns det ringa information om rörförluster i fjärrkylasystem. Föreliggande studie fokuserar på förluster i ett fjärrkylanät genom att både använda ett R-nätverk och FEM simuleringsmodeller. Ett R-nätverksmodell bestående av termiska konduktanser har utvecklats genom analytiska ekvationer och simuleringar med FEM har utfört för validering av modellen. Därefter har ett fjärrkylanätverk som konstrueras i Gävle, analyserats. Undersökningen omfattar 15 olika rördiametrar i tre utföranden (dubbelrör med två symmetriska och en osymmetrisk värmeisolering) och i tre förläggningsdjup (0,8; 2 och 4 meter) för en säsong om 7 månader (April t o m Oktober). Särskilt utreds ökningen av temperaturen hos framledningsmediet, där matningsrören förlagts i en å mitt i staden om en sträcka av 1 km. Den maximala förlusten under säsongen, bland alla rörkonfigurationer, motsvarar 2 % av den totala levererade energin. Slutligen konstateras att kombinationen av isolerad framledningsrör och oisolerade returrör verkar som en gångbar investering, ekonomiskt och tekniskt, men kan inte användas i hela nätet eftersom stora delar har redan byggts med oisolerade plaströr. R-nätverksmodellen, som visades vara effektiv och pålitlig i undersökningen, kan som beräkningsverktyg, framförallt för dimensionering och för att uppskatta energiförluster. / Distribution losses are a very important factor in district energy systems. By optimizing the losses in such a system, both economical and environmental aspects can be fulfilled. Unfortunately, there is few information regarding losses for district cooling systems. This study focuses on losses in district cooling networks by using both R-network and FEM simulation models. A R-network model composed of thermal conductances has been developed through analytical equations and simulations have been performed for validation. Afterwards, an in-progress construction project of a district cooling network from the city of Gävle, Sweden, is analyzed. The assessment consists of 15 pipe diameters in three configurations (two symmetric cases and one asymmetric), at three ground laying depths (0.8, 2 and 4 meters) for a duration of 7 months (April to October). A particular case in which the main distribution pipes from and to the plant are submerged in the city’s river for a distance of 1 km is investigated in order to estimate the temperature increase of the supply water. A maximum cooling loss below 2% of the total delivered energy during the season for any network configuration resulted from the calculation. Finally, the mixed pipes array seems to be a feasible investment both economically and technically but it cannot be used for the entire network spread since a part of the network has been already built with the non-insulated plastic pipes. The R-network model proved to be effective and reliable in the analysis which provides confidence that it can serve as a solid foundation for a calculation tool - primarily for design purposes and also for estimating energy loss.

Page generated in 0.1037 seconds