• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 13
  • Tagged with
  • 13
  • 8
  • 6
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Ajuste incremental de estabilizadores para geradores e dispositivos TCSC-POD em sistemas de potência. / Incremental adjustment of stabilizers for generators and TCSC-POD devices in power systems.

Moraco, Anna Giuglia Menechelli 02 March 2015 (has links)
O constante aumento da demanda de energia elétrica sobre as redes e a necessidade de interligação de sistemas através de longas linhas de transmissão, culminaram em problemas relacionados à estabilidade do sistema de potência multimáquinas. Tais problemas envolvem oscilações eletromecânicas de baixa frequência classicadas como modos interáreas. Os modos interáreas são caracterizados por oscilações de frequências de até 1Hz e representam oscilações de um grupo de geradores de uma área contra grupos de geradores de outras áreas. Umavezqueoempregodeestabilizadoresdesistemasdepotência(ESP)possanãosersucienteparagarantirumamortecimentoadequadoaessesmodos,osdispositivosFACTSsurgem como uma alternativa ecaz para o amortecimento de oscilações de baixa frequência. Para este m, o Capacitor Série Controlado por Tiristor (TCSC - Thyristor Controlled Series Capacitor) é um dispositivo FACTS comumente empregado e quando utilizado juntamente com um controlador suplementar para amortecimento de oscilações de potência (POD - Power Oscillation Damping) garante ao sistema de potência estabilidade e amortecimento adequado. Assim, o objetivo deste trabalho de mestrado é realizar o projeto coordenado de controladores ESP e TCSC-POD efetuando um ajuste incremental dos parâmetros dos controladores através da formulação do problema por otimização e programação quadrática. Tal técnica foi utilizada anteriormente somente para o projeto de ESPs. No caso deste trabalho será feita uma adaptação para estender a possibilidade de aplicação da metodologia para casos com dispositivos FACTS presentes. / The increasing demand for electricity over networks and the need for systems interconnection through long transmission lines, resulted in problems related to the multi-machine power systemstability. Theseproblemsinvolvelowfrequencyoscillationsclassiedasinterareasmodes. These modes are characterized by oscillations in frequencies up to 1 Hz, and represent a group of generators from one area oscillating against generator groups from other areas. Once the use of power system stabilyzers (PSS) controllers may not be sucient to ensure adequate damping to these modes, the FACTS devices emerge as an ecient alternative to damping low frequency oscillations. For this purpose, the TCSC (Thyristor Controlled Series Capacitor)isacommonlyusedFACTSdeviceandwhenitisusedtogetherwithasupplementary controller POD (Power Oscillation Damping), ensures stability to power system and adequate damping. These controllers have the same structure as the PSS controllers. Therefore, the objective of this work is to carry out the coordinated design of PSS and TCSC-POD controllers, performing an incremental adjustment of the controllers parameters by formulating the problem as an optimization problem using quadratic programming. This method was previously used only for PSS design. In the case of this work, it is made an adaptation to extend the applicability of the methodology for cases in which there are FACTS devices present.
12

Análise do amortecimento de modos interáreas com o método de imposição de polos. / Analysis damping of modes inter-area with the method of imposition of poles.

Carlos Alberto Febres Tapia 18 July 2013 (has links)
Este trabalho aborda as oscilações eletromecânicas de baixa frequência, relativas a modos interáreas, pouco amortecidos, avaliando o seu impacto no desempenho de redes elétricas multi-máquinas com o objetivo de elevar o amortecimento destes modos com equipamentos TCSC. Os locais apropriados para instalação destes equipamentos são escolhidos com a análise dos resíduos de funções de transferência e o ajuste de parâmetros, para o projeto coordenado de controladores, utiliza o método de imposição de polos. O sistema não linear de equações, obtido com a aplicação do método de imposição de polos, supondo coeficientes de amortecimento pré-estabelecidos, é resolvido utilizando-se o método de Newton Raphson. Adicionalmente, avalia-se a possibilidade do método auxiliar na análise de interações entre controladores e identificação de acoplamentos, por meio da análise dos termos que compõem as equações de imposição de polos. / This work deals with low frequency oscillations related to inter-area modes, evaluating their impact on the performance of multi-machine electrical networks with the aim to increase the damping of these modes using TCSC. The best places to install these devices are chosen with the analysis of the residues of transfer functions and the parameter fitting for coordinated application of stabilizers is performed with the pole placement method. The nonlinear system of equations, obtained with the pole placement method, assuming specified damping factors, is solved with the Newton-Raphson method. The method is also used in the analysis of control interaction among stabilizers through the evaluation of individual parcels of the pole placement equations, as an additional feature of the approach.
13

Proposta e avaliação de um modelo computacional de gerador central de padrões / Proposal and evaluation of a computational model of Central Pattern Generator

BORGES, Marco Aurélio de Faria 02 June 2011 (has links)
Made available in DSpace on 2014-07-29T15:08:17Z (GMT). No. of bitstreams: 1 Dissertacao Marco A de F Borges.pdf: 5922161 bytes, checksum: 25a7f4da4201499fe0a986400e8ae5b8 (MD5) Previous issue date: 2011-06-02 / The concept of Central Pattern Generator-CPG can be described as neural network capable of producing coordinated rhythmic locomotor activity apart from any external rhythm or sensorial stimuli. As this group of neurons are autonomic and are located in the spinal medulla, is experimentally observed that brainless animal‟s exhibit robotized locomotor activity, for its march has no defined direction nor respond to any obstacles. Studies has shown that is possible to activate this specialized networks using specific drugs or electric stimuli depending only of the access area as brainstem, medulla or some brain areas. For this paper many models proposed in current literature were evaluated, in its majority conceptual models. Within this models the Rybak (2006) computational model was chosen to be reproduced and evaluated regarding its robustness. The model in question consist in a CPG based in experimental data collected in cats and it posses two level of neurons based in the half-center models in its structure, the Rhythmic Generator-RG and the Pattern Formation-PF. This groups control the activity of the motoneurons flexors and extensors in an articulation. For its implementation were necessary a simplification in the original model and new parameterization of the variables. The implemented model allows a locomotor activity simulation produced by the CPG when stimulating a Mesencephalic Locomotion Region. Two protocols of variation of conductance inn GR were applied intending to evaluate its strength. The results show that the CPG computer model created operates within physiological values in variations up to . This model presents an adaptation in the first and the current is the current that plays a major role in the occurrence of outbreaks. The conductance has a direct relationship with the period as a result of its increase, a decrease in frequency of the bursts occurs. The conductance of has an inverse relationship with the period and as a result of its increase, a decrease in the period and increased in the frequency of the bursts occurs. The conductance has a direct relation with the period of the bursts before the 100% and a reverse relation after 100% of the reference value. The default behavior extensor/ flexor dominant not only depend on the synaptic weight of RLM, but rather the result of all the conductance values that make up the neuron GR. / O conceito de Gerador Central de Padrões (do inglês Central Pattern Generator-CPG) pode ser descrito como redes neuronais capazes de produzir atividade locomotora rítmica coordenada, independente de qualquer ritmo externo ou estímulos sensoriais. Como esses conjuntos de neurônios são autônomos e estão situados na medula espinhal, observa-se experimentalmente que animais descerebrados exibem uma atividade locomotora robotizada, assim chamada por que não tem direção definida e, também, não reagem a obstáculos. Estudos demonstram que é possível ativar essas redes especializadas por fármacos ou estímulos elétricos, dependendo da área de acesso, como: tronco encefálico, medula ou algumas áreas do cérebro. Para esse trabalho foram levantados vários modelos propostos na literatura, na maioria, modelos conceituais. Dentre os quais, foi identificado o modelo computacional de Rybak (2006) e então escolhido para ser reproduzido e avaliado com relação à sua robustez. O modelo em questão consiste em um CPG baseado em dados experimentais obtidos em gatos e possui dois níveis de neurônios baseados no modelo half-center em sua estrutura, o Gerador Rítmico-GR e Formador de Padrão-FP. Esses grupos controlam a atividade dos Motoneurônios flexores e extensores de uma articulação. Para implementação foram necessários uma simplificação no modelo original e nova parametrização das variáveis. O modelo implementado permite simular atividade locomotora produzida pelo CPG ao estimular a Região Locomotora Mesencefálica. Foram aplicados dois protocolos de variação das condutâncias no GR no intuito de avaliar sua robustez. Os resultados indicam que o modelo computacional de CPG criado opera dentro de valores fisiológicos sob variações de até . Esse modelo apresenta uma adaptação nos primeiros e a corrente é a corrente que desempenha o papel principal na ocorrência dos surtos.A condutância tem uma relação direta com o período dos surtos e em consequência ao seu aumento ocorre uma diminuição na frequência dos surtos. A condutância de tem uma relação inversa com o período dos surtos e em consequência ao seu aumento, ocorre uma diminuição no período e aumento na frequência dos surtos. A condutância tem uma relação direta com o período dos surtos antes de e inversa após do valor de referência. O comportamento padrão extensor/ flexor dominante não depende apenas do peso sináptico da RLM, mas sim, do resultado de todos os valores de condutância que compõem o neurônio GR.

Page generated in 0.0392 seconds