• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • 4
  • 3
  • 3
  • Tagged with
  • 15
  • 15
  • 5
  • 5
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Určení vlivu iontů ve struktuře hydroxidu nikelnatého / The influence of metal ions on nickel hydroxide structure

Navrátil, Jan January 2010 (has links)
Diploma thesis is involved in basic properties of nickel materials for alkaline accumulators. Practical part deals with measuring of nickel hydroxides by cyclic voltametry. Next practical part is above measuring and optimalization various proportion of nickel and cobalt in layer made by electrodeposition on nickel electrodes.
2

SYNTHESIS AND CHARACTERIZATION OF POLYANILINE, SUBSTITUTED POLYNAILINES AND THEIR COMPOSITES COATS ON AL-2024

SHAH, KUNAL G. 11 October 2001 (has links)
No description available.
3

Conductive And Electrochromic Properties Of Poly(p-phenylene Vinylene)

Ozturk, Tugba 01 January 2005 (has links) (PDF)
P-xylene-bis(diethylsulphonium chloride) (PXBDC) monomer was synthesized by the reaction of &amp / #945 / ,&amp / #945 / -dichloro-p-xylene with tetrahydrothiophene or diethyl sulphide. Electrochemical behavior of this monomer (PXBDC) was examined by cyclic voltametry. Polymerization was achieved both by using electrochemical and chemical polymerization techniques. In the electrochemical technique, PPV was synthesized by constant potential electrolysis in acetonitrile-tetrabutylammonium tetrafluoroborate (TBAFB) solvent-electrolyte couple. The polymer obtained from the electrode surface was converted to the poly(p-phenylene vinylene) (PPV) by the thermal elimination reaction of diethyl sulphide and HCl. Also, PPV was doped via electrochemical doping with ClO4- dopant ion. The chemical structures were confirmed both by Nuclear Magnetic Resonance Spectroscopy (NMR) and Fourier Transform Infrared Spectroscopy (FTIR). The thermal behavior of chemically and electrochemically synthesized conducting polymers were investigated by Differential Scanning Calorimetry (DSC). Also, electrochromic and spectroelectrochemical properties of PPV was investigated by using UV-VIS spectrophotometer.
4

Záporná elektroda lithných sekundárních článků / Negative Electrode of Lithium Secondary Cells

Makovička, Jaromír January 2008 (has links)
The thesis deals with a study of the various carbon materials for negative electrode of lithium ion accumulators. The object of the work is to gain the most knowledge about these materials and to project their possible improvements. In the first part of the work is described the latest knowledge about carbon materials and their application. In the following parts of the work is handled about manufacture,optimization of composition of electrode and the choice of carbon material for liquid and gel electrolyte.
5

Caracterização por ressonância de plasmons de superfície de biossensores eletroquímicos aplicados à detecção de neurotoxinas. / Characterization by surface plasmon resonance of electrochemical biosensors applied to neurotoxins detection.

Souza, Diego Custódio de 13 November 2013 (has links)
Os dispositivos biossensores foram primeiramente pesquisados por Clark e Lyons, em 1962, visando medir o nível de glicemia. Atualmente, há uma popularização dos medidores de glicemia e diversas tecnologias foram desenvolvidas, principalmente, para aplicações em diagnósticos médicos e monitoramento ambiental. No entanto, há uma ampla quantidade de aplicações para biossensores ainda não disponível no mercado. A imobilização de espécies bioativas que interagem diretamente com o analito, chamada de superfície bioativa, é frequentemente considerada a etapa mais difícil no desenvolvimento de biossensores para novas aplicações. O objetivo deste trabalho é demonstrar a caracterização da camada bioativa desenvolvida pela técnica de construção de camadas auto-organizadas usando o princípio da adsorção eletrostática. Para isto, foram utilizadas três diferentes concentrações de soluções compostas por ligações covalentes entre nanotubos de carbono de paredes múltiplas e três diferentes biomateriais, Polietilenoimina, Ácido Desoxirribonucléico e enzimas do tipo Hidrolase de Organofosforados. As diferentes soluções polieletrolíticas foram caracterizadas pela técnica de ressonância de plasmons de superfície e simultaneamente formaram camadas auto-organizadas na superfície de um eletrodo de carbono vítreo. A atividade das enzimas foi analisada por voltametria cíclica para as diferentes concentrações das soluções utilizadas. Os resultados mostraram que a caracterização por ressonância de plasmons de superfície promove o controle da adsorção eletrostática. A variação do ângulo de ressonância de plasmons de superfície corresponde à intensidade e à saturação das interações eletrostáticas entre as camadas. Biossensores desenvolvidos com soluções de maior concentração, consequentemente, ampliaram os limites de detecção e elevaram a resolução do sinal elétrico. Em aplicações para medir baixas concentrações do analito, o adequado controle das concentrações das soluções poli eletrolíticas reduz os custos no desenvolvimento de biossensores especialmente, com relação ao custo de enzimas isoladas. / The biosensor devices were first researched by Clark and Lyons in 1962, aiming to measure the blood glucose level. Currently, there is a popularization of blood glucose meters and several technologies have been developed mainly for applications in medical diagnostics and environmental monitoring. However, there is a wide range of applications for biosensors not yet available. The immobilization of bioactive species that interact directly with the analyte, called bioactive surface, is often considered the most difficult step in the biosensors development for new applications. The objective of this work is to demonstrate the characterization of the bioactive surface developed by self-assembled monolayers technique using the electrostatic adsorption principle. For this, we used three different concentrations of solutions composed of covalent bonds between multi-walled carbon nanotubes and three different biomaterials, Polyethyleneimine, Deoxyribonucleic Acid and Organophosphorous Hydrolase enzymes. These enzymes catalyze the hydrolysis of phosphorus compounds such as organophosphorous neurotoxins. The different polyelectrolyte solutions were characterized by the technique of surface plasmon resonance, and simultaneously, self-assembled monolayers were formed on the surface of a glassy carbon electrode. The enzymes activity was analyzed by cyclic voltammetry for the different concentrations of the solutions used. The results showed that the surface plasmon resonance characterization promote the control of electrostatic adsorption. The variation of the surface plasmon resonance angle corresponds the intensity and saturation of electrostatic interactions between the layers. Biosensors developed with solutions of higher concentration, consequently, widened the detection limits, and increased the resolution of the electrical signal. In applications to measure low concentrations of analyte, adequate control of the concentrations of polyelectrolytes solutions reduces costs in the development of biosensors especially, the cost of isolated enzymes.
6

Caracterização por ressonância de plasmons de superfície de biossensores eletroquímicos aplicados à detecção de neurotoxinas. / Characterization by surface plasmon resonance of electrochemical biosensors applied to neurotoxins detection.

Diego Custódio de Souza 13 November 2013 (has links)
Os dispositivos biossensores foram primeiramente pesquisados por Clark e Lyons, em 1962, visando medir o nível de glicemia. Atualmente, há uma popularização dos medidores de glicemia e diversas tecnologias foram desenvolvidas, principalmente, para aplicações em diagnósticos médicos e monitoramento ambiental. No entanto, há uma ampla quantidade de aplicações para biossensores ainda não disponível no mercado. A imobilização de espécies bioativas que interagem diretamente com o analito, chamada de superfície bioativa, é frequentemente considerada a etapa mais difícil no desenvolvimento de biossensores para novas aplicações. O objetivo deste trabalho é demonstrar a caracterização da camada bioativa desenvolvida pela técnica de construção de camadas auto-organizadas usando o princípio da adsorção eletrostática. Para isto, foram utilizadas três diferentes concentrações de soluções compostas por ligações covalentes entre nanotubos de carbono de paredes múltiplas e três diferentes biomateriais, Polietilenoimina, Ácido Desoxirribonucléico e enzimas do tipo Hidrolase de Organofosforados. As diferentes soluções polieletrolíticas foram caracterizadas pela técnica de ressonância de plasmons de superfície e simultaneamente formaram camadas auto-organizadas na superfície de um eletrodo de carbono vítreo. A atividade das enzimas foi analisada por voltametria cíclica para as diferentes concentrações das soluções utilizadas. Os resultados mostraram que a caracterização por ressonância de plasmons de superfície promove o controle da adsorção eletrostática. A variação do ângulo de ressonância de plasmons de superfície corresponde à intensidade e à saturação das interações eletrostáticas entre as camadas. Biossensores desenvolvidos com soluções de maior concentração, consequentemente, ampliaram os limites de detecção e elevaram a resolução do sinal elétrico. Em aplicações para medir baixas concentrações do analito, o adequado controle das concentrações das soluções poli eletrolíticas reduz os custos no desenvolvimento de biossensores especialmente, com relação ao custo de enzimas isoladas. / The biosensor devices were first researched by Clark and Lyons in 1962, aiming to measure the blood glucose level. Currently, there is a popularization of blood glucose meters and several technologies have been developed mainly for applications in medical diagnostics and environmental monitoring. However, there is a wide range of applications for biosensors not yet available. The immobilization of bioactive species that interact directly with the analyte, called bioactive surface, is often considered the most difficult step in the biosensors development for new applications. The objective of this work is to demonstrate the characterization of the bioactive surface developed by self-assembled monolayers technique using the electrostatic adsorption principle. For this, we used three different concentrations of solutions composed of covalent bonds between multi-walled carbon nanotubes and three different biomaterials, Polyethyleneimine, Deoxyribonucleic Acid and Organophosphorous Hydrolase enzymes. These enzymes catalyze the hydrolysis of phosphorus compounds such as organophosphorous neurotoxins. The different polyelectrolyte solutions were characterized by the technique of surface plasmon resonance, and simultaneously, self-assembled monolayers were formed on the surface of a glassy carbon electrode. The enzymes activity was analyzed by cyclic voltammetry for the different concentrations of the solutions used. The results showed that the surface plasmon resonance characterization promote the control of electrostatic adsorption. The variation of the surface plasmon resonance angle corresponds the intensity and saturation of electrostatic interactions between the layers. Biosensors developed with solutions of higher concentration, consequently, widened the detection limits, and increased the resolution of the electrical signal. In applications to measure low concentrations of analyte, adequate control of the concentrations of polyelectrolytes solutions reduces costs in the development of biosensors especially, the cost of isolated enzymes.
7

Preparo, caracterização e aplicação eletroanalítica de nanopartículas de pentacianonitrosilferrato(III) de cobre sobre a superfície de óxido de grafeno /

Maraldi, Vitor Alexandre January 2018 (has links)
Orientador: Devaney Ribeiro do Carmo / Resumo: Este trabalho apresenta a preparação do óxido de grafeno (OG) através do Método de Hummers Modificado e subsequente modificação química de sua superfície com nanopartículas de pentacianonitrosilferrato(III) de cobre (OGCuNP). Os materiais obtidos foram caracterizados por diferentes técnicas, tais como: Espectroscopia na Região do Infravermelho com Transformada de Fourier, Espectroscopia Raman, Espectroscopia de Fotoelétrons Excitados por Raios-X, Microscopia Eletrônica de Varredura, Microscopia Eletrônica de Transmissão e Difração de Raios-X. O OGCuNP foi caracterizado por Voltametria Cíclica, empregando um eletrodo de pasta de grafite. O voltamograma cíclico do OGCuNP exibiu dois pares redox bem definidos com potencial médio (Eθ’) de 0,27 V e 0,77 V, para o primeiro e segundo par redox, que foram atribuídos aos processos redox Cu(I)/Cu(II) e Cu(II)Fe(II)(CN)5NO/Cu(II)Fe(III)(CN)5NO, respectivamente. O eletrodo de pasta de grafite modificado com OGCuNP apresentou resposta eletrocatalítica à três substâncias, a saber: hidrazina, isoniazida e N-acetilcisteína. Para a eletro-oxidação catalítica da hidrazina, o eletrodo de pasta de grafite modificado com OGCuNP apresentou resposta linear com concentração em um intervalo de 1,0×10-5 a 5,0×10-3 mol L-1 de hidrazina, com limite de detecção de 1,58×10-6 mol L-1. O eletrodo modificado também exibiu atividade eletrocatalítica para isoniazida, nos picos anódicos I e II, apresentando limite de detecção de 6,93×10-5 mol L-1 e de 2,16×10-5... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This work presents the prepare of graphene oxide (OG) by the Modified Hummers Method, besides the chemical modification of its surface with nanoparticles of copper pentacyanonitrosylferrate(III) (OGCuNP). The materials obtained were characterized by different techniques, such as: Fourier Transform Infrared Spectroscopy, Raman Spectroscopy, X-Ray Photoelectron Spectroscopy, Scanning Electron Microscopy, Transmission Electron Microcopy and X-Ray Diffraction. The OGCuNP was characterize by the Cyclic Voltammetry technique, where the graphite paste electrode was used. The cyclic voltammogram of the OGCuNP exhibited two well-defined redox pairs with medium potential (Eθ’) 0,27 V and 0,77 V, for the first em second redox process, attributed to the redox processes of Cu(I)/Cu(II) and Cu(II)Fe(II)(CN)5NO/Cu(II)Fe(III)(CN)5NO, respectively. The graphite paste electrode modified with OGCuNP presented electrocatalytic response for three substances: hidrazine, isoniazide and N-acetylcysteine. For catalytic electro-oxidation of hidrazine, the grafite paste electrode modified with OGCuNP presented linear response in the concentration between 1,0×10-5 and 5,0×10-3 mol L-1 of hidrazine, with detection limit of 1,58×10-6 mol L-1. The modified electrode too exhibited electrocatalytic activity for isoniazide for the both anodic peaks I and II, and it presented detection limit of 6,93×10-5 mol L-1 and 2,16×10-5 mol L-1 in a concentration range of 6,0×10-5 to 6,0×10-3 mol L-1 and 6,0×10-4 to 7,0×... (Complete abstract click electronic access below) / Mestre
8

Preparo, caracterização e aplicação eletroanalítica de nanopartículas de pentacianonitrosilferrato(III) de cobre sobre a superfície de óxido de grafeno / Prepare, characterization and electroanalytical application of copper pentacyanonitrosylferrate(III) on the graphene oxide suface

Maraldi, Vitor Alexandre 23 August 2018 (has links)
Submitted by Vitor Alexandre Maraldi (vitor.maraldi@unesp.br) on 2018-09-25T18:18:02Z No. of bitstreams: 1 VITOR ALEXANDRE MARALDI - DISSERTAÇÃO DE MESTRADO - PPGCM.pdf: 2617548 bytes, checksum: 63b9cbae1372330aed7477cb3f68209f (MD5) / Approved for entry into archive by Cristina Alexandra de Godoy null (cristina@adm.feis.unesp.br) on 2018-09-25T19:08:40Z (GMT) No. of bitstreams: 1 maraldi_va_me_ilha.pdf: 2617548 bytes, checksum: 63b9cbae1372330aed7477cb3f68209f (MD5) / Made available in DSpace on 2018-09-25T19:08:40Z (GMT). No. of bitstreams: 1 maraldi_va_me_ilha.pdf: 2617548 bytes, checksum: 63b9cbae1372330aed7477cb3f68209f (MD5) Previous issue date: 2018-08-23 / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Este trabalho apresenta a preparação do óxido de grafeno (OG) através do Método de Hummers Modificado e subsequente modificação química de sua superfície com nanopartículas de pentacianonitrosilferrato(III) de cobre (OGCuNP). Os materiais obtidos foram caracterizados por diferentes técnicas, tais como: Espectroscopia na Região do Infravermelho com Transformada de Fourier, Espectroscopia Raman, Espectroscopia de Fotoelétrons Excitados por Raios-X, Microscopia Eletrônica de Varredura, Microscopia Eletrônica de Transmissão e Difração de Raios-X. O OGCuNP foi caracterizado por Voltametria Cíclica, empregando um eletrodo de pasta de grafite. O voltamograma cíclico do OGCuNP exibiu dois pares redox bem definidos com potencial médio (Eθ’) de 0,27 V e 0,77 V, para o primeiro e segundo par redox, que foram atribuídos aos processos redox Cu(I)/Cu(II) e Cu(II)Fe(II)(CN)5NO/Cu(II)Fe(III)(CN)5NO, respectivamente. O eletrodo de pasta de grafite modificado com OGCuNP apresentou resposta eletrocatalítica à três substâncias, a saber: hidrazina, isoniazida e N-acetilcisteína. Para a eletro-oxidação catalítica da hidrazina, o eletrodo de pasta de grafite modificado com OGCuNP apresentou resposta linear com concentração em um intervalo de 1,0×10-5 a 5,0×10-3 mol L-1 de hidrazina, com limite de detecção de 1,58×10-6 mol L-1. O eletrodo modificado também exibiu atividade eletrocatalítica para isoniazida, nos picos anódicos I e II, apresentando limite de detecção de 6,93×10-5 mol L-1 e de 2,16×10-5 mol L-1, em uma faixa de concentração de 6,0×10-5 a 6,0×10-3 mol L-1 e 6,0×10-4 a 7,0×10-3 mol L-1 de isoniazida, respectivamente. Para a detecção de N-acetilcisteína, o eletrodo de pasta de grafite modificado com OGCuNP apresentou atividade eletrocatalítica apenas para o pico anódico II, com limite de detecção de 2,63×10-5 mol L-1 e intervalo de concentração de 5,0×10-4 a 6,0×10-3 mol L-1 de N-acetilcisteína. Realizou-se ainda uma investigação da influência dos principais interferentes na detecção eletrocatalítica dos analitos estudados, de forma que a interferência observada não mostrou-se significativa. Desta maneira, o complexo bimetálico formado inclui-se no rol dos materiais obtidos como potenciais candidatos para a construção de sensores eletroquímicos na detecção de hidrazina, isoniazida e N-acetilcisteína. / This work presents the prepare of graphene oxide (OG) by the Modified Hummers Method, besides the chemical modification of its surface with nanoparticles of copper pentacyanonitrosylferrate(III) (OGCuNP). The materials obtained were characterized by different techniques, such as: Fourier Transform Infrared Spectroscopy, Raman Spectroscopy, X-Ray Photoelectron Spectroscopy, Scanning Electron Microscopy, Transmission Electron Microcopy and X-Ray Diffraction. The OGCuNP was characterize by the Cyclic Voltammetry technique, where the graphite paste electrode was used. The cyclic voltammogram of the OGCuNP exhibited two well-defined redox pairs with medium potential (Eθ’) 0,27 V and 0,77 V, for the first em second redox process, attributed to the redox processes of Cu(I)/Cu(II) and Cu(II)Fe(II)(CN)5NO/Cu(II)Fe(III)(CN)5NO, respectively. The graphite paste electrode modified with OGCuNP presented electrocatalytic response for three substances: hidrazine, isoniazide and N-acetylcysteine. For catalytic electro-oxidation of hidrazine, the grafite paste electrode modified with OGCuNP presented linear response in the concentration between 1,0×10-5 and 5,0×10-3 mol L-1 of hidrazine, with detection limit of 1,58×10-6 mol L-1. The modified electrode too exhibited electrocatalytic activity for isoniazide for the both anodic peaks I and II, and it presented detection limit of 6,93×10-5 mol L-1 and 2,16×10-5 mol L-1 in a concentration range of 6,0×10-5 to 6,0×10-3 mol L-1 and 6,0×10-4 to 7,0×10-3 mol L-1 of isoniazide, respectively. For the detecction of N-acetylcysteine, the graphite paste electrode modified with OGCuNP presented electrocatalytic activity only for the anodic peak II, with detection limit of 2,63×10-5 mol L-1 and concentration range of 5,0×10-4 to 6,0×10-3 mol L-1 of N-acetylcysteine. It still was investigated the influence of the main interferentes in the electrocatalytic detection of the analyzed analytes, so that the noticed interferences were not significant. By this way, the bimetallic complex formed is included in the list of materials obtained as potential candidates for the construction of electrochemical sensors in the hidrazine, isoniazide and N-acetylcysteine detection.
9

Superkondenzátory s kapalnými aprotickými elektrolyty / Liquid electrolytes for supercapacitors

Bill, Jan January 2008 (has links)
This work deals with the preparation of liquid electrolytes from different types of aprotic solvents with the aim of their application as electrolytes in electrochemical supercapacitors. Different sorts of aprotic solvents have been chosen, in which the following forms of salts were used: LiBF4, LiClO4,LiPF6. In the next part of the work, the properties of these solvents were measured and the best electrolyte, according to the biggest possible capacity of the system, was chosen. In the theoretical part of this work, the physical principle of supercapacitors and their propeties are described. It deals with electrolytes, their division and with the properties that are appropriate for supercapacitors. The experimental part of the work describes the process of preparation of the samples of electrodes, electrolytes and the techniques of measuring their capacities.
10

Monomeric, Dimeric and Polymeric Re<sup>I</sup>(CO)<sub>3</sub> Schiff Base Complexes: Synthetic, Spectroscopic, Electrochemical, and Computational Studies

Hasheminasab, S. Abed 09 June 2016 (has links)
No description available.

Page generated in 0.0713 seconds