• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • 1
  • 1
  • 1
  • Tagged with
  • 6
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Une classe d'intervalles bay??siens pour des espaces de param??tres restreints

Ghashim, Ehssan January 2013 (has links)
Ce m??moire traite d'une m??thode bay??sienne, analys??e par Marchand et Strawderman (2013), pour la construction d'intervalles bay??siens pour des mod??les de densit??s continues avec contrainte sur l'espace des param??tres ??. Notamment, on obtiendra une classe d'intervalles bay??siens I??0,??(.), associ??s ?? la troncature d'une loi a priori non informative ??0 et g??n??r??s par une fonction de distribution ??(.), avec une probabilit?? de recouvrement born??e inf??rieurement par 1-??/1+??. Cette classe inclut la proc??dure HPD donn??e par Marchand et Strawderman (2006) dans le cas o?? la densit?? sous-jacente d'un pivot est sym??trique. Plusieurs exemples y illustrent la th??orie ??tudi??e. Finalement, on pr??sentera de nouveaux r??sultats pour la probabilit?? de recouvrement des intervalles bay??siens appartenant ?? la classe ??tudi??e pour des densit??s log-concaves. Ces r??sultats ??tablissent la borne inf??rieure ?? 1- 3??/2 et g??n??ralisent les r??sultats de Marchand et al.(2008) tenant sous une hypoth??se de sym??trie.
2

Etude des propriétés optiques du système supraconducteur Ba122 à base de fer par spectroscopie infrarouge

Dai, Yaomin 08 December 2011 (has links) (PDF)
Lorsque des atomes sont assemblés dans un solide, des nouveaux phénomènes surgissent en raison de l'interaction forte entre noyaux et électrons. Par exemple, dans des matériaux anisotropes de faible dimension ou dans des m étaux à forte densité d' états au niveau de Fermi, de densité de spin (SDW) ou de charge (CDW) peuvent se former à basse température. La supraconductivité est présente dans certains matériaux quand il refroidit en dessous d'une température critique. Toutes ces phases peuvent apparaître d'une façon isolée ou coexister avec une autre. Et, dans ce cas, une interaction forte ou de la compétition peut exister entre ces phases. Le mécanisme de formation de ces phases et les relations entre elles sont toujours le centre d'intérêt quand elles sont découvertes dans un nouveau matériau. Ba1−xKxFe2As2 et Ba(Fe1−xCox)2As2 ont été découverts comme une nouvelle famille de supraconducteurs à haute Tc. C'est le système supraconducteur Ba122 à base de fer. Le composé parent de cette famille est BaFe2As2 qui a une transition d'onde de densité de spin à environ 138 K. Lorsque le dopage du composé parent est fait par des trous [Ba1−xKxFe2As2] ou par des électrons [Ba(Fe1−xCox)2As2], le magnétisme est supprimé et la supraconductivité apparaît. Dans une gamme de dopage considérablement large, la phase SDW et la supraconductivité coexistent. Dans ce cas, la symétrie du gap supraconducteur les relations entre les ordres coexistants produisent des phénomènes et des comportements nouveaux. Dans cette thèse, nous avons étudié les propriétés optiques des supraconducteurs à base de fer dopés trous [Ba1−xKxFe2As2] et électrons [Ba(Fe1−xCox)2As2]. Dans les composés dopés optimalement par K ou Co, nous avons trouvé différentes réponses dans la conductivité optique de basse énergie. En comparant les propriétés optiques et les sites de dopage de ces deux échantillons dopés de fa con optimale, nous avons fourni des preuves solides pour une symétrie d'appariement s± dans le système Ba122. Dans le composé sous-dopé Ba0.6K0.4Fe2As2 nous avons observé, en plus du gap SDW et de celui supraconducteur, un plus petit gap à plus faible énergie. Nous avons étudié la dépendance en température et dopage des trois gaps. Avec cela, combinée à une analyse de poids spectral, nous avons conclu que ce gap nouveau partage les mêmes états électroniques que le condensat supraconducteurs. Nous avons interprété ce gap par un scénario de précurseur de la phase supraconductrice. En revanche, la transition SDW diminue les états électroniques disponibles pour le condensat supraconducteur, agissant comme un ordre en compétition à la supraconductivité.
3

Identificação da expressão do vascular endothelial growth factor (VEGF) pela contagem de células marcadas imunoistoquimicamente no omento de ratos após ligadura arterial e após ligadura venosa

Zart, Ronald Paulo Pinto January 2007 (has links)
O sistema cardiovascular está estrutural e funcionalmente disposto de modo “circular”. Situações de obstrução do fluxo sanguíneo determinam o aparecimento de mecanismos que visam suplantar tais interrupções e manter a circularidade íntegra. À nível molecular, o principal elemento envolvido nestes mecanismos é o Vascular Endothelial Growth Factor (VEGF). A expressão do VEGF quando há oclusão arterial está bem documentada, faltando elementos com relação à oclusão venosa. Neste estudo objetivamos verificar se a oclusão à nível arterial determina uma expressão do VEGF diferente daquela que ocorre se a oclusão acontecer à nível venoso. Para isso randomizamos dois grupos de ratos de experimentação. Em um grupo realizamos a oclusão da aorta infra-renal e em outro a oclusão da veia cava infra-renal. Posteriormente medimos a expressão do VEGF através da contagem do número de células marcadas imunoistoquimicamente no omento destes ratos. O resultado demonstrou que a expressão do VEGF, quando analisada pelo método proposto foi igual no grupo da oclusão venosa e no grupo da oclusão arterial. / The cardiovascular system is structurally and functionally circular. Situations in which there is obstruction to blood flow trigger mechanisms to bypass these blockages and maintenance the integrity of the circularity. At the molecular level the main factor involved is the Vascular Endothelial Growth Factor (VEGF). The VEGF expression associated with arterial occlusion is well documented but is lacking evidence when venous occlusion occurs. This study aimed to verify if the expression of VEGF when an occlusion occurs at venous level is the same or different from that caused at the arterial level. Two groups of rats were randomized by infra-renal aortic occlusion or inferior vena cava occlusion. VEGF was measured by counting the immunohistochemistry method marked cells at the omentum level. It was demonstrated that the VEGF expression is the same in the venous group obstruction as the arterial obstruction group.
4

Identificação da expressão do vascular endothelial growth factor (VEGF) pela contagem de células marcadas imunoistoquimicamente no omento de ratos após ligadura arterial e após ligadura venosa

Zart, Ronald Paulo Pinto January 2007 (has links)
O sistema cardiovascular está estrutural e funcionalmente disposto de modo “circular”. Situações de obstrução do fluxo sanguíneo determinam o aparecimento de mecanismos que visam suplantar tais interrupções e manter a circularidade íntegra. À nível molecular, o principal elemento envolvido nestes mecanismos é o Vascular Endothelial Growth Factor (VEGF). A expressão do VEGF quando há oclusão arterial está bem documentada, faltando elementos com relação à oclusão venosa. Neste estudo objetivamos verificar se a oclusão à nível arterial determina uma expressão do VEGF diferente daquela que ocorre se a oclusão acontecer à nível venoso. Para isso randomizamos dois grupos de ratos de experimentação. Em um grupo realizamos a oclusão da aorta infra-renal e em outro a oclusão da veia cava infra-renal. Posteriormente medimos a expressão do VEGF através da contagem do número de células marcadas imunoistoquimicamente no omento destes ratos. O resultado demonstrou que a expressão do VEGF, quando analisada pelo método proposto foi igual no grupo da oclusão venosa e no grupo da oclusão arterial. / The cardiovascular system is structurally and functionally circular. Situations in which there is obstruction to blood flow trigger mechanisms to bypass these blockages and maintenance the integrity of the circularity. At the molecular level the main factor involved is the Vascular Endothelial Growth Factor (VEGF). The VEGF expression associated with arterial occlusion is well documented but is lacking evidence when venous occlusion occurs. This study aimed to verify if the expression of VEGF when an occlusion occurs at venous level is the same or different from that caused at the arterial level. Two groups of rats were randomized by infra-renal aortic occlusion or inferior vena cava occlusion. VEGF was measured by counting the immunohistochemistry method marked cells at the omentum level. It was demonstrated that the VEGF expression is the same in the venous group obstruction as the arterial obstruction group.
5

Identificação da expressão do vascular endothelial growth factor (VEGF) pela contagem de células marcadas imunoistoquimicamente no omento de ratos após ligadura arterial e após ligadura venosa

Zart, Ronald Paulo Pinto January 2007 (has links)
O sistema cardiovascular está estrutural e funcionalmente disposto de modo “circular”. Situações de obstrução do fluxo sanguíneo determinam o aparecimento de mecanismos que visam suplantar tais interrupções e manter a circularidade íntegra. À nível molecular, o principal elemento envolvido nestes mecanismos é o Vascular Endothelial Growth Factor (VEGF). A expressão do VEGF quando há oclusão arterial está bem documentada, faltando elementos com relação à oclusão venosa. Neste estudo objetivamos verificar se a oclusão à nível arterial determina uma expressão do VEGF diferente daquela que ocorre se a oclusão acontecer à nível venoso. Para isso randomizamos dois grupos de ratos de experimentação. Em um grupo realizamos a oclusão da aorta infra-renal e em outro a oclusão da veia cava infra-renal. Posteriormente medimos a expressão do VEGF através da contagem do número de células marcadas imunoistoquimicamente no omento destes ratos. O resultado demonstrou que a expressão do VEGF, quando analisada pelo método proposto foi igual no grupo da oclusão venosa e no grupo da oclusão arterial. / The cardiovascular system is structurally and functionally circular. Situations in which there is obstruction to blood flow trigger mechanisms to bypass these blockages and maintenance the integrity of the circularity. At the molecular level the main factor involved is the Vascular Endothelial Growth Factor (VEGF). The VEGF expression associated with arterial occlusion is well documented but is lacking evidence when venous occlusion occurs. This study aimed to verify if the expression of VEGF when an occlusion occurs at venous level is the same or different from that caused at the arterial level. Two groups of rats were randomized by infra-renal aortic occlusion or inferior vena cava occlusion. VEGF was measured by counting the immunohistochemistry method marked cells at the omentum level. It was demonstrated that the VEGF expression is the same in the venous group obstruction as the arterial obstruction group.
6

Diseño y caracterización de metamateriales acústicos basados en guías de onda

Graciá Salgado, Rogelio 14 July 2014 (has links)
En la realización de este trabajo se obtendrán las expresiones analíticas que permiten describir las propiedades acústicas de una red de elementos dispersivos en el interior de una guía de ondas, permitiendo así, obtener en el límite de homogenización los parámetros efectivos que caracterizan al metamaterial y la verificación experimental de las propiedades acústicas del metamaterial. Matemáticamente este problema se tratará con la teoría de la dispersión múltiple, ya que las geometrías a tratar en este trabajo van a ser cilíndricas y dicha teoría se ha demostrado ser la mas efectiva para esos casos y usando la técnica de ¿mode matching ¿para la resolución general del problema de la dispersión de campo acústico en el interior de una guía de ondas. / Graciá Salgado, R. (2014). Diseño y caracterización de metamateriales acústicos basados en guías de onda [Tesis doctoral]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/38759

Page generated in 0.0265 seconds