• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2304
  • 155
  • 150
  • 150
  • 148
  • 109
  • 35
  • 35
  • 24
  • 17
  • 17
  • 12
  • 7
  • 5
  • 2
  • Tagged with
  • 2362
  • 1247
  • 1039
  • 886
  • 534
  • 523
  • 493
  • 433
  • 425
  • 347
  • 234
  • 192
  • 180
  • 166
  • 163
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Avaliação da aplicação de uma solução ácida experimental na resistência de união de sistemas adesivos

Melara, Rafael January 2010 (has links)
Made available in DSpace on 2011-12-27T14:14:28Z (GMT). No. of bitstreams: 2 000430098-0.pdf: 130972 bytes, checksum: 7163cf89fa076e570e8462a27723ebe0 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / This study aimed to evaluate, in vitro, the bond strength of adhesive systems Adper Scotchbond SE (3M/ESPE) and Adper Scotchbond Multi-Purpose (3M/ESPE) to dentin treated or not with an experimental acid solution. The occlusal surface of twenty sound human molars was removed to obtain a flat dentin area. The teeth were divided into four groups according to the type of adhesive system used and whether the experimental solution was used or not. In groups Adper Scotchbond SE Control and Scotchbond Multi-Purpose Control, the adhesive system was applied according to the manufacturer's instructions. In group Adper Scotchbond SE Experimental, an experimental solution was applied previously to the adhesive system, and in group Adper Scotchbond Multi¬Purpose Experimental, the phosphoric acid 37% was replaced by the application of experimental solution. After applying the adhesive system, a block of composite resin (Z350 - 3M/ESPE), with approximately 6 mm in height was made. After, the teeth were stored in distilled water for 24 h in a culture oven at 37°C. Thereafter, the teeth were sectioned in the direction "x" and "y" to obtain sticks with adhesive area of approximately 1. 0 mm2. Sixteen sticks by group were tested in a microtensile testing machine (EMIC DL-2000) at a speed of 0. 5 mm/min. After the microtensile test, the sticks were evaluated by SEM, to establish the predominant pattern of failure by fractography. According to the analysis of variance two-way there was no statistically significant difference in bond strength values among the four groups. The predominant type of failure observed in SEM was cohesive in the adhesive, followed by cohesive in the hybrid layer. SEM analysis showed that the experimental solution was able to remove the smear layer exposing dentin tubules. Based on these results we conclude that the use of experimental solution in combination with the adhesive systems was able to promote values of bond strength similar to the technique of application as recommended by the manufacturers, and this experimental acid solution was able to obtain a conditioning of dentin surface similar to that obtained with 37% phosphoric acid. / Este estudo teve por objetivo avaliar, in vitro, a resistência de união dos sistemas adesivos Adper Scotchbond SE (3M/ESPE) e Adper Scotchbond Multi-Uso (3M/ESPE) à superfície dentinária tratada ou não com uma solução ácida experimental. A superfície oclusal de vinte terceiros molares humanos hígidos foi removida para a obtenção de uma área plana de dentina. Os dentes foram divididos em 4 grupos, de acordo com o tipo de sistema adesivo usado e aplicação ou não da solução experimental. Nos grupos Adper Scotchbond SE Controle e Adper Scotchbond Multi-Uso Controle, o sistema adesivo foi aplicado de acordo com as instruções do fabricante. No grupo Adper Scotchbond SE Experimental foi aplicada a solução experimental previamente ao sistema adesivo, e no grupo Adper Scotchbond Multi-Uso Experimental, o condicionamento com ácido fosfórico a 37% foi substituído pela aplicação da solução experimental. Após a aplicação do sistema adesivo, um bloco de resina composta (Z350 - 3M/ESPE), com aproximadamente 6 mm de altura, foi confeccionado, sendo os dentes armazenados em água destilada por 24 h em uma estufa de cultura a 37°C. Decorrido este período, os dentes foram seccionados nos sentido “x” e “y” a fim de obter palitos com área adesiva de aproximadamente 1,0 mm2. Dezesseis palitos por grupo foram submetidos ao teste de microtração em uma máquina de ensaios (EMIC DL-2000), a uma velocidade de 0,5 mm/min. Após o teste de microtração, os palitos foram avaliados em microscopia eletrônica de varredura, para estabelecimento do padrão predominante de falha, por meio de fractografia. De acordo com a análise de variância segundo duas vias não houve diferença estatisticamente significativa nos valores de resistência de união entre os quatro grupos, para os fatores adesivos e tratamentos de superfície. O tipo de falha predominante observado em MEV foi coesiva em adesivo, seguido de coesiva em camada híbrida.A análise em MEV mostrou que a solução experimental foi capaz de remover a smear layer expondo túbulos dentinários. Com base nos resultados encontrados é possível concluir que o uso da solução experimental contendo um inibidor de metaloproteinases, em associação aos sistemas adesivos estudados, foi capaz de promover valores de resistência de união 3 semelhantes à técnica de aplicação recomendada pelos fabricantes; e que essa solução ácida experimental foi capaz de obter um padrão de condicionamento de superfície dentinária semelhante ao obtido com o ácido fosfórico a 37%.
52

Tratamentos de superfície para aumentar a resistência de união adesiva à zircônia

Paranhos, Maria Paula Gandolfi January 2010 (has links)
Made available in DSpace on 2011-12-27T14:14:30Z (GMT). No. of bitstreams: 2 000427526-0.pdf: 20667486 bytes, checksum: 1d99d8d1b05458aa30749d927735a2df (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / Foram realizados dois estudos in vitro para avaliar resistência de união de cimentos resinosos à zircônia após diferentes tratamentos de superfície e um estudo in vitro para avaliar a resistência à fadiga de coroas não-retentivas cimentadas adesivamente em pilares de zircônia conforme protocolo adesivo definido pelos estudos de resistência de união.
53

Resistencia a fratura de pre-molares restaurados com amalgama : efeito de bases adesivas

Murrer, Rodrigo Dutra 04 July 1997 (has links)
Orientador: Jose Roberto Lovadino / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-22T10:35:00Z (GMT). No. of bitstreams: 1 Murrer_RodrigoDutra_M.pdf: 2098367 bytes, checksum: dec18ee2bc6c226e32c71d4bf05335ea (MD5) Previous issue date: 1997 / Resumo: o objetivo do trabalho foi estudar a resistência à fratura de pré-molares inferiores em função da colocação de bases adesivas. Para isso, 84 dentes extraídos, íntegros e livres de trincas ou manchas, foram divididos, aleatoriamente, em sete grupos de doze dentes. Os dentes do grupo 1 não receberam preparo nem restauração. No grupo 2, os dentes receberam um preparo MOD, sem caixas proximais e com o assoalho plano, de largura correspondente a 1/4 da distância intercuspidal e de profundidade correspondente a 3/8 da altura da coroa. As amostras pertencentes a esse grupo não foram restauradas. Os dentes dos grupos 3 ao 7 receberam o mesmo tipo de preparo, porém com a profundidade correspondente a 3/4 da altura da coroa dental, sendo que os do grupo 3 não foram restaurados e os dos grupos de 4 a 7 foram restaurados, respectivamente, com: amálgamaadesivo; base de cermet + amálgama; base de CIV híbrido + amálgama; base de resina composta + amálgama. Todos os grupos foram submetidos a teste de resistência à compressão em máquina universal de ensaios. A carga foi aplicada axialmente através de uma esfera de aço posicionada de maneira a manter contato apenas com as vertentes das cúspides e nunca com as restaurações ou as margens das cavidades. As médias das cargas necessárias para fraturar as amostras de cada grupo foram (em kg): G1 =130,24 ; G2=45,45; G3=22,33; G4=65,62; G5=47,05; G6=57,03; G7=120,62. A análise estatística dos resultados, através do Teste de Tukey, demonstrou diferenças estatisticamente significantes entre alguns grupos. O grupo 1 foi o que demonstrou os maiores resultados, sendo igualado, estatisticamente, apenas pelo grupo 7. Os grupos 4, 5 e 6 não demonstraram diferença estatística entre si e, embora não tenham conseguido recuperar totalmente a resistência perdida, apresentaram diferença significante em relação ao grupo 3. O grupo 4 apresentou superioridade ainda sobre o grupo 2, o que não foi conseguido pelos grupos 5 e 6 / Abstract: The aim of this study was to evaluate the fracture resistance of premolars with MOD cavities preparations, restored with amalgam and with different materiais used as liners. Eight four sound and free from cracks extracted mandibular premolars were randomly assingned to seven groups of twelve teeth. The teeth from group 1 did not receive either cavity preparation or restoration. In the group 2, the teeth received a MOD cavity preparation without proximal steps and flat floor. The preparation had the isthmus width equal to 1/4 of the intercuspidal distance and the cavity deep was 3/8 of the crown height. Teeh from this group were not restored. The cavity preparation in the teeth from group 3 to 7 was the same, but the deep was doubled. Teeth from group 3 were not restored and from group 4 to 7 were restored respectively with: bonded-amalgam; cermet lining + amalgam; GIC modified lining + amalg'am; composite resin lining + amalgam. Ali groups were submitted to fracture resistance test in a universal test machine. The load was applied vertically through a metalic sphere of 4,5 mm diameters positioned to touch only the cusps and never the restorations or margins of cavities. The mean load necessary to fracture the samples in each group were (in kg): G1=130,24 ; G2=45,45; G3=22,33; G4=65,62; G5=47,05; G6=57,03; G7=120,62. These data were submitted to Tukey's test that demonstrated diferences among some groups. Group 1 showed the best results Equaled??? just by group 7. The group 4, 5 and 6 were not different among them and, although they did not recover totally the resistance lost, they showed a significant diference compared to group 3. Group 4 showed better results than group 2, the same was not reached by groups 5 and 6 / Mestrado / Dentística / Mestre em Clínica Odontológica
54

Avaliação de deposição superficial de corante em ionomeros de vidro modificados por resina submetidos a tratamentos superficiais

Liporoni, Priscila Christiane Suzy 26 September 1997 (has links)
Orientador: Luis Alexandre Maffei Sartini Paulillo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-22T19:00:05Z (GMT). No. of bitstreams: 1 Liporoni_PriscilaChristianeSuzy_M.pdf: 2141251 bytes, checksum: a3ac5173dc3d07b4b25bd1c21f88f27b (MD5) Previous issue date: 1997 / Resumo: O acabamento e polimento de restaurações diretas são essenciais para se obter uma lisura superficial adequada. O propósito deste estudo foi avaliar "in vitro" a deposição superficial de corante em ionômeros de vidro modificados por resina quando submetidos a diferentes tratamentos superficiais de acabamento e polimento. Os materiais foram manipulados de acordo com as instruções dos fabricantes, inseridos em uma matriz de acrílico, cobertos com uma tira de poliéster e fotopolimerizados. Vinte e quatro amostras de cada material, Photac-Fil ( Espe ) e Fuji II LC ( GC Corporation ) foram divididas em três grupos: Tira matriz ( GC ); Pontas Enhance ( GI ); Discos Sof-Iex fino e extra-fino ( Gil ). Todas as amostras foram submetidas ao teste de manchamento através do corante azul de metileno e quantificados num espectrofotômetro. Foi feita a Análise de Variância para comparação entre as médias e então aplicado o Teste de Tukey ( a = 0,05% ). As médias (Jlg/ rnl) para cada material foram: Photac-Fil, GC = 0,999; GI = 1,175; Gil = 1,157 e Fuji II LC, GC = 0,0~01; GI = 0,547; GIl = 0,0001. Concluiu-se que a melhor superfície foi obtida quando os materiais polimerizaram junto à tira matriz. Entre os materiais utilizados no acabamento e polimento, os discos Sof-Iex apresentaram melhores resultados para o híbrido Fuji II LC / Abstract: Finishing is essential to obtain appropriate smooth surfaces of direct restorations increasing the longevity of them. The purpose of this study was to evaluate "in vitro" superficial dye deposition on resin modified glass-ionomer submitted to different surface finishing treatments. The materiaIs were mixed following the manufactures directions, inserted into split molds, covered with a matrix strip and polymerized. Twenty-four samples of the each material, Photac-fil ( Espe ) and Fuji 11 LC ( GC Corporation ) were divided into three finishing groups: (I) Mylar matrix ( control); (11) disks Sof-Iex ( fine and ultra-fine); (111) Enhance system. AlI samples were submitted to staining test by dye uptake and were quantified by spectrophotometry. The results were analysed by ANOV A and Tukey's test. The means Ü.lg! rnl) for each material were: Photac-Fil, GC = 0,999; GI = 1,175; GIl = 1,157 and Fuji 11 LC, GC = 0,0001; GI = 0,547; GIl = 0,0001. It was concluded that the best surface was obtained when the materiaIs were cured in contact with the Mylar matrix strip. Among the materials used for surface finishing Sof-Iex presented the best results to Fuji 11 LC / Mestrado / Dentística / Mestre em Clínica Odontológica
55

Resistencia a tração de agentes cimentantes usados na fixação de ligas de paladio-prata e niquel-cromo a dentina

Freitas, Gersinei Carlos de 21 March 2000 (has links)
Orientador: Lourenço Correr Sobrinho / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-26T02:35:04Z (GMT). No. of bitstreams: 1 Freitas_GersineiCarlosde_D.pdf: 4162353 bytes, checksum: 73f549d9460534321d100928321de41f (MD5) Previous issue date: 2000 / Resumo: o propósito deste estudo foi avaliar a resistência à tração da união de dois tipos de ligas metálicas (Litecast B e Pors-on 4) fixadas em dentina humana tratada sob três condições (condicionada por 1O segundos com ácido fosfórico 35%, ácido poliacrílico 25% e não condicionada). Os cimentos foram 1- de fosfato de zinco, 2- ionômero d vidro e, 3- cimento resinoso. Noventa molares humanos foram inseridos em resina acrílica e desgastados com lixas d'água de granulação nOs 120, 320 e 600 até aproximadamente 2 mm além da junção amelo-dentinária. Noventa corpos-de-prova com 6,0 mm de diâmetro por 7 mm de altura foram confeccionados, sendo quarenta e cinco com liga de níquel-cromo (Litecast B) e quarenta e cinco com liga paládio-prata (Pors-on 4). Quinze corpos-de-prova de cada liga foram fixadas com os cimentos de fosfato de zinco (55 White), ionômero de vidro (Vitremer - 3M) e cimento resinoso (3M). Antes da fixação, a dentina de cinco corpos-de-prova foi condicionada com ácido fosfórico 35%, cinco com ácido poliacrílico 25%, ambas por 1O segundos e cinco não condicionadas. Todos os corpos-de-prova foram armazenados a 37°C por 24 horas antes do ensaio. Em seguida, os corpos-de-prova foram submetidos ao ensaio de tração em uma máquina Instron a velocidade de 0,5 mm/min. até a separação entre liga metálica e dente. Os resultados foram submetidos a análise de variância e ao teste de Tukey (p<0,05). Os dados indicaram que: Para a liga Pors-on 4 o cimento de resina apresentou valores de resistência à remoção, por tração, estatisticamente superiores ao cimento de ionômero de vidro e de fosfato de zinco para as três condições de tratamento da dentina. O cimento de ionômero de vidro apresentou valores estatisticamente superior ao de fosfato de zinco, para a dentina condicionada com ácido fosfório 35% e ácido poliacrílico 25%. Nenhuma diferença estatística foi encontrada entre o cimento de ionômero de vidro e fosfato de zinco para a superfície não condicionada; Para a liga Litecast B, o cimento de resina apresentou valores de remoção, por tração, estatisticamente superiores aos cimentos de fosfato de zinco e de ionômero de vidro para a dentina condicionada com ácido fosfórico 35% e poliacrílico 25%. O cimento de fosfato de zinco foi superior ao de resina para a dentina não condicionada. Nenhuma diferença foi observada entre o cimento de fosfato de zinco e de ionômero de vidro para as três condições da dentina e entre o cimento de ionômero de vidro e de resina para a dentina não condicionada. Para as duas ligas, o cimento de resina mostrou valores de remoção, por tração, superiores aos do fosfato de zinco e ionômero de vidro. De uma maneira geral, a liga liga Pors-on 4 apresentou valores de resistência a remoção por tração estatisticamente superiores a liga Litecast B, para todos os cimentos e tratamentos da dentina / Abstract: The aim of this study was to evaluate the tensile bond strength of two alloy systems (Litecast B and Pors-on 4) luted with three cements to dentin in three conditions (etched with 35% phosphoric acid, 25% polyacrylic acid for 10 seconds and no etching). Ninety extracted human molars were embedded in resin with 10 mm in diameter of exposed dentin which had been grounded with 120, 320 and 600 grit SiC paper. Forty-tive specimens with 6.0 mm in diameter and 7.0 mm long, were fabricated with nickel chromium-beryllium (Litecast B) and palladium-silver (Pors-on 4) alloys. Fifteen specimens of each alloy systems were luted with zinc phosphate cement (SS White), glass ionomer cement (3M) and resin cement (3M). Prior to cementation, the dentin of five specimens were etched with 35% phosphoric acid, tive with 25% polyacrylic acid for 10 seconds and tive no etching. Ali samples were stored in distilled water at 37° C for 24 hours prior to testing. After the specimens were submitted to the tensile bond strength in an Instron at a crosshead speed of 0.5 mm/min until failure. The results were submitted to variance analysis and Tukey's test (p<0.05). The data indicated that for Pors-on 4: the resin cement showed tension bond strength values stronger than glass ionomer cement and zinc phosphate cement in three dentin conditions (p<0. 05). Glass ionomer cement showed values stronger than zinc phosphate for dentin etched with phosphoric acid and polyacrilic acid. For no etching no difference was found between glass ionomer cement and zinc phosphate cement; for Litecast B: the resin cement was signiticantly stronger than zinc phosphate and glass ionomer cement for dentin etched with two acid. Zinc phosphate was stronger than resin cement for dentin no etching. No difference was found between zinc phosphate and glass ionômero cement in three dentin conditions and between glass ionomer cement and resin cement to the dentin no etching. For the two alloy systems the resin cement showed tensile bond strength better than glass ionomer and zinc phosphate cement for three dentin conditions. In general, Pors-on 4 alloy showed tension strength values stronger than Litecast B alloy, in three dentin conditions and cements / Doutorado / Doutor em Materiais Dentários
56

Avaliação da resistencia ao cisalhamento de braquetes fixados a ceramica com diferentes tratamentos superficiais e agentes de cimentação

Borges, Gilberto Antonio 12 June 2000 (has links)
Orientador: Lourenço Correr Sobrinho / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-27T09:59:32Z (GMT). No. of bitstreams: 1 Borges_GilbertoAntonio_M.pdf: 3479582 bytes, checksum: 48667180de177d8d86f6c782a513e22b (MD5) Previous issue date: 2000 / Resumo: O propósito deste estudo foi avaliar a resistência ao cisalhamento de bráquetes fixados à cerâmica dental, utilizando as variáveis: materiais para colagem, tratamento superficial e aplicação do silano. Foram confeccionados 192 discos de cerâmica (Duceram) com 5 mm de diâmetro por 2 mm de espessura. Os discos foram embutidos com resina acrílica ativada quimicamente em tubos de P.V.C. e divididos em 4 grupos de 48 discos de acordo com o tratamento de superfície: Grupo I - condicionamento com ácido fosfórico 37%, por 30 segundos; Grupo 11 - condicionamento com ácido hidrofluorídrico a 10%, por 2,0 minutos; Grupo 111 - jateado com óxido de alumínio por 4 segundos; e, Grupo IV submetido apenas a profilaxia com pedra pomes e água por 30 segundos. Vinte e quatro corpos-de-prova de cada grupo receberam aplicação de silano e vinte e quatro não. Três materiais para colagem Transbond XT, Concise e Fuji Ortho LC foram utilizados para fixação dos bráquetes à cerâmica para cada grupo (com e sem silano) perfazendo um total de 64 fixações por material. Todas as amostras foram armazenadas em água destilada a 37° C, por 24 horas. Em seguida, as amostras foram submetidas ao teste de resistência ao cisalhamento numa máquina Instron a velocidade de 1,0 mm/min. Os resultados foram submetidos a análise de variância e ao teste de Tukey 5% de significância. Os resultados mostraram que independente do tratamento superficial da cerâmica e silanização o Transbond XT mostrou valores de resistência ao cisalhamento superiores em relação ao Concise e Fuji Ortho LC (p<0,05); o tratamento superficial da cerâmica com ácido hidrofluorídrico mostrou valores de resistência ao cisalhamento superiores em relação ao jateamento com óxido de alumínio, com condicionamento com ácido fosfórico e profilaxia com pedra pomes e água, independente do material para colagem e silanização (p<O,O5); e, a aplicação do silano aumentou a resistência da união cerâmicalbráquete para os três materiais e tratamentos superficiais, exceto para os bráquetes fixados na cerâmica com o Concise em superfícies submetidas à profilaxia com pedra pomes e água / Abstract: The purpose of this study was to evaluate the shear bond strength of brackets fixed on dental ceramic using three different materials with or without silane. One hundred ninety two specimens with 5 mm in diameter and 2 mm thickness were made with ceramic (Duceram). The specimens were divided into four groups according to surface treatments: Group I - acid etching with 37% phosphoric acid for 30 seconds; Group 11 - acid etching 10% hydrofluoridric acid for 2,0 minutes; Group 111 - Sandblasting with aluminum oxide for 4 seconds; and, Group IV - cleaned with pumice slurry. Twenty-four specimens of each group was treated with silane agents and twenty-four remained untreated. The brackets were bonded to ceramic with Transbond XT, Concise and Fuji Ortho LC. Ali specimens were stored in distilled water 37° C for 24 hours. After that the specimens were submitted to shear bond strength in an Instron at a crosshead speed of 1,0 mm/min. The results were submitted to variance analyses and Tukey's test (p<0.05). The date indicated that the Transbond XT showed higher values of shear bond strength than Concise and Fuji Ortho LC independent of the treatment on ceramic surface (p<0.05); the ceramic etching with hydrofluoridric acid of the ceramic showed higher values shear bond strength than the others three treatments for ali specimens (p<0.05); and the treatement with silane increased the shear bond strength of ceramic/bracket interface for ali materials, except Concise cleaned with pumice slurry on surface ceramic / Mestrado / Mestre em Materiais Dentários
57

Resistencia de união a tração de sistemas adesivos sobre dentina aos 10 minutos e 24 horas pos-polimerização

Cunha, Marcia Regina Bernardi da 19 February 2001 (has links)
Orientador : Mario Fernando de Goes / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-28T00:32:05Z (GMT). No. of bitstreams: 1 Cunha_MarciaReginaBernardida_M.pdf: 2234174 bytes, checksum: d5064ae556f27764bd71a1f2aca5f61e (MD5) Previous issue date: 2001 / Resumo: O objetivo deste estudo foi avaliar a resistência de união à tração de sistemas adesivos dentinários convencionais e autocondicionantes aos 10 minutos e 24 horas pós-polimerização. Superfícies dentinárias planas foram preparadas nas faces superfícies vestibulares de 120 incisivos inferiores bovinos e sobre as quais foi delimitada a área de união de 4mm de diâmetro com fita adesiva. Nos grupos citados foram aplicados os seguintes sistemas adesivos seguidos da aplicação da resina composta Z 100: Grupo A e B - ScotchBond Multi-Uso Plus; Grupos C e D - Single Bond; Grupos E e F- Clearfil Liner Bond 2Ve Grupos G e H - Clearfil SE Bond. Nos Grupos A, B, C e D foi efetuado condicionamento com ácido fosfórico a 35% sobre a dentina por 15 segundos, seguida da lavagem e remoção do excesso de água. Um cilindro de resina composta foi posicionado sobre a área de união delimitada e fotoativado por 20 segundos em três pontos da interface para a realização do ensaio de tração, que foi conduzido após 10 minutos da união para os Grupos A, C, E e G. Os grupos B, D, F e H foram armazenados em água destilada a 37°C e o teste foi realizado após 24 horas em máquina de ensaio universal Instron com velocidade de 0,5mm/minuto, após o qual, o padrão de fratura foi observado sob Microscopia Eletrônica de Varredura. Os resultados foram submetidos à análise de variância e teste de Tukey (p< 0,05). Os resultados do ensaio de tração expressos em MPa foram: Grupo A- 7,69 +/- 1,40; Grupo B- 7,86 +/- 2,66; Grupo C- 8,56 +/- 2,97, Grupo D- 7,99 +/- 2,12; Grupo E­ 11,46 +/- 1,96; Grupo F- 12,97 +/- 2,86, Grupo G-11 ,73 +/- 3,01 e Grupo H- 13,04 +/- 3,57. Não houve diferença estatística significativa entre 10 minutos e 24 horas (p<O,05) para todos os grupos testados e os sistemas adesivos autocondicionantes foram estatisticamente superiores aos demais sistemas adesivos (p<O,05). O padrão de fratura predominante para os grupos de ScotchBond Multi-Uso e Single Bond foi coesivo no adesivo! Camada híbrida e nos grupos dos sistemas autocondicionantes foi coesiva em dentina. Os sistemas adesivos convencionais ScotchBond Multi-Uso e Single Bond, e os sistemas autocondicionantes Clearfil Liner Bond 2V e Clearfil SE Bond, apresentaram zonas de interdifusão resina! dentina com características morfológicas distintas, tanto em relação à espessura quanto na formação dos prolongamentos resinosos decorrentes da penetração do adesivo nos túbulos dentinários / Abstract: The purpose of this study was to evaluate the tensile bond strength of conventional dentin adhesive systems and self-etching primers at 10 minute and 24 hours. Flat dentin surfaces were prepared on labial surface of 120 bovine lower incisor teeth and a 4-mm-diameter bonding area was demarcated on each prepared surface with adhesive vinyl tape. In the following groups were applied the dentin systems and the composite resin Z 100: Groups A and B ¿ ScotchBond Multi-Purpose Plus and Z 100; Groups C and O - Single Bond; Groups E and F­ Clearfil Liner Bond 2V and Groups G and H - Clearfil SE Bond. In the groups A, B, C and O ali dentin was etched with 35% phosphoric acid, washed and the excess of water was removed. A resin composite rod was positioned on the bonding area and cured for 20 s at the three points of the interface to perform the tensile bond strength (TBS). The TBS was tested at 10 minute to groups A, C, E and G. The groups B, O, F and H were stored in distilled water at 37°C and the TBS was performed after 24 h. An Instron testing machine was used with a cross-head speed of 0,5 mm/min for the tensile test. After the TBS, the fracture pattern was observed by SEM. The results were analysed by ANOVA and Tukey's test (p<0,05). The TBS results expressed by MPa were: Group A- 7.69 +/- 1.40; Group B­ 7.86+/- 2.66; Group C- 8.56+/- 2.97, Group 0- 7.99+/- 2.12; Group E- 11.46+/- 1.96; Group F- 12.97 +/- 2.86, Group G-11.73 +/-3.01 and Group H- 13.04 +/- 3.57. There was no statistically significant difference among the 10 min and 24h groups. The more frequently fracture pattern was cohesive on the adhesive system for the A,B, C and o; and the Groups E, F, G and H showed cohesive fracture of dentin. The TBS of ali dentin bonding systems were similar at 10 min and 24 h and the self etching primers showed the highest values of TBS. The conventional adhesive systems, ScotchBond Multi-Use Plus and Single Bond, and the self etching primers, Clearfil Liner Bond 2V and Clearfil SE Bond, showed distinct morphological characteristics at resin dentin interdifusion zones about their thickness and resin tags created because of the infiltration of the adhesive resin into the dentin tubules / Mestrado / Mestre em Materiais Dentários
58

Avaliação da resistencia da união composito/dentina ao cisalhamento em dentes deciduos submetidos ao tratamento com hipoclorito de sodio

Correr-Nolasco, Gisele Maria 31 March 2003 (has links)
Orientador: Regina Maria Puppin-Rontani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-03T06:00:37Z (GMT). No. of bitstreams: 1 Correr-Nolasco_GiseleMaria_M.pdf: 5607867 bytes, checksum: bb98da2fe571d84a31f2c91744a11f0a (MD5) Previous issue date: 2003 / Resumo: O objetivo deste estudo foi avaliar diferentes sistemas de união (Single Bond - SB, Prime & Bond 2.1 - PB e Clearfil SE Bond - CSEB), aplicados à dentina de dentes decíduos, submetida ou não ao tratamento prévio com hipoclorito de sódio (NaDCI), através da análise da resistência da união ao cisalhamento (RC) e do aspecto morfológico da união compósito/dentina. Foram selecionados 45 molares decíduos hígidos extraídos. As raízes dos dentes foram seccionadas na junção cemento-esmalte e as coroas ao meio, no sentido mésiodistal. As amostras foram então embutidas com resina de poliestireno em tubos de PV.C., com a superfície vestibular, lingual ou palatina externamente e lixadas até a obtenção de uma superfície plana em dentina (3 mm de diâmetro). A seguir, foram aleatoriamente distribuídas em 6 grupos (n=15), sendo: G1 - aplicação do sistema SB; G2 - condicionamento ácido (CA), aplicação de NaOCI seguida pelo sistema SB; G3 - aplicação do sistema PB; G4 - CA, aplicação do NaOCI seguida pelo sistema PB; G5 - aplicação do sistema CSEB e G6 - aplicação de NaOCI, seguida pelo CSEB. Todos os sistemas de união foram aplicados de acordo com as instruções dos fabricantes. O NaOCI a 10%foi aplicado nos grupos 2,4 (após o condicionamento ácido) e 6 (antes da aplicação do sistema de união) por 60s, e o dente foi lavado por 30s e seco com papel absorvente. Em seguida, o compósito Filtek Z-250 foi inserido em três incrementos (aproximadamente 2 mm), em uma matriz bipartida de silicone por adição adaptada a um posicionador metálico, e fotoativado por 20s cada incremento. As amostras foram armazenadas em água destilada a 37°C por 24h e então submetidas ao ensaio de cisalhamento em uma Máquina de Ensaio Universal (Instron - modelo 4411) à velocidade de 0,5mm/min. Os padrões de fratura foram observados em microscópio estereoscópico (aumento 25X), e os representativos de cada grupo foram observados em Microscopia Eletrônica de Varredura (MEV). Para a análise da união compósito/dentina foram utilizados três dentes para cada grupo e repetidos todos os procedimentos descritos anteriormente. Emseguida, foram seccionados no centro da restauração e preparados para observação em MEV. Os dados obtidos no ensaio de cisalhamento foram submetidos à análise de variância e teste de Tukey (p<0,05). Os valores obtidos em MPa foram: G1- 3,17 :t 1,97; G2 - 2,93 :t 1,36; G3 - 2,04 :t 0,27; G4 - 1,91 :t 0,74; G5 - 2,67 :t 1,22; G6 -2,14 :t 1,10. De acordo com os resultados, pôde-se observar que houve diferença estatística significativa (p<0,05) entre os materiais (SB-CSEB-PB). Não houve diferença estatística significativa entre os grupos com ou sem tratamento do substrato, independente do material utilizado (p>0,05). O tipo de falha freqüentemente observada em todos os grupos foi a falha mista (coesiva no compósito + adesiva). Com relação ao aspecto . morfológico da união, nas amostras sem tratamento do substrato foi observada a presença da camada híbrida e dos prolongamentos resinosos. Nas amostras com tratamento da superfície (com NaOCI) não foi observada a presença da camada híbrida, porém foram observados prolongamentos resinosos. Pôde-se concluir que o tratamento da superfície com hipoclorito de sódio não afetou a resistência da união compósito/dentina ao cisalhamento, porém, interferiu na formação da camada híbrida, em dentes decíduos / Abstract: The aim of this study was to evaluate different bonding agents (Single Bond - SB, Prime & Bond 2.1 - PB e Clearfil SE Bond - CSEB), in primary teeth treated with sodium hypochlorite (NaOCI) on the shear bond strength (SBS) and micromorphology of the resin/dentin interface. Forty-five sound extracted primary molars were selected. The roots were sectioned in the enamel-cement junction and the crowns longitudinally, in the mesio-distal sense. The samples were embedded in polystyrene resin with the bucal, lingual or palatine surface externally and they were flattened until dentin surface was reached (3mm in diameter). Then, the samples were randomly assigned in 6 groups (n=15), and received the following treatments: G1 - SB; G2 - acid etching (AE), 10% NaOCI and the SB; G3 - PB; G4 - AE, 10% NaOCI and the PB; G5 - CSEB; G6 - 10% NaOCI followed by CSEB. Ali the adhesive systems were applied according to manufactures' instructions. The 10% NaOCI solution was applied for 60s in groups 2,4 (after acid etching), and 6 (before adhesive system), washed for 30s and dried with tissue paper. Next, the composite resin was inserted in increments (2mm) in a vinyl polysiloxane impression material matrix, adapted in a metallic holder, and light cured for 20s (each increment). The samples were stored in distilled water at 37°C for 24h and then, submitted to SBS test in a universal testing machine (Instron - model 4411) with a crosshead speed of 0.5mm/min. The failure sites were observed in stereoscope microscopy of 40X magnification, and the representative failures of each group were observed in Scanning Electron Microscopy (SEM). The results obtained were submitted to ANOVA and Tukey's tests (p<0.05). The values in MPa were: G1- 3.17 :t 1.97;G2 - 2.93:t 1.36;G3 - 2.04:t 0.27; G4- 1.91 :t 0.74; G5 - 2.67:t 1.2; G6 -2.4:t 1.0. According to the results, it could be noticed that there was a statistical significant difference (p<0.05) among the materiais (SB- CSEB PB). There was no statistical significant difference (p>0.05) among ali the groups with or without treatment of the substrate, independently of the material used. The mixed fail (cohesive in resin + adhesive) was the one most frequently observed in ali groups. Regarding the interface aspect in specimens without substrate treatment (NaDCI) it could be observed the presence of the hybrid layer and resin tags whereas treated specimens only resin tags could be observed. It could be concluded that the treatment of the dentin surface with sodium hypochlorite did not affect the resin/dentin bonding strength but interfered in the hybrid layer formation in primary teeth / Mestrado / Mestre em Materiais Dentários
59

Avaliação da resistencia a fratura e a fadiga, a seco e em agua, da ceramica in ceram fixadas com agentes de cimentação

Reges, Rogerio Vieira 03 August 2018 (has links)
Orientador : Lourenço Correr Sobrinho / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-03T08:17:47Z (GMT). No. of bitstreams: 1 Reges_RogerioVieira_M.pdf: 2233963 bytes, checksum: 2c2aad43bb4c45742b0b41d97eb7b03d (MD5) Previous issue date: 2003 / Mestrado
60

Avaliação da resistencia a microtratação da união de sistemas adesivos autocondicionantes a dentina com e sem previo jateamento de oxido de aluminio e apos diferentes periodos de armazenamento em agua

Gomes, Fabiana Mantovani 03 August 2018 (has links)
Orientador: Jose Roberto Lovadino / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-03T20:23:46Z (GMT). No. of bitstreams: 1 Gomes_FabianaMantovani_D.pdf: 4297950 bytes, checksum: 524424e020c903b8627c7f75df517f7d (MD5) Previous issue date: 2004 / Doutorado

Page generated in 0.0453 seconds