• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 73
  • 5
  • 5
  • 5
  • 5
  • 5
  • 4
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 73
  • 73
  • 42
  • 27
  • 22
  • 17
  • 14
  • 13
  • 10
  • 9
  • 9
  • 6
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Influencia da escovação mecanica na manutenção do acabamento com resinas fluidas sobre compositos odontologicos

Ferreira, Anna Cristhina Fiore 26 July 2018 (has links)
Orientador: Mario Alexandre Coelho Sinhoreti / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-26T06:23:02Z (GMT). No. of bitstreams: 1 Ferreira_AnnaCristhinaFiore_M.pdf: 4629927 bytes, checksum: c3422261ee870ba71df4aac4cceed90c (MD5) Previous issue date: 1999 / Resumo: Algumas alterações microestruturais na superfície dos compósitos podem ser originadas pelo processo mastígatório e pelos procedimentos de acabamento e polimento, podendo propagar-se continuamente pela área superficial e subsuperficial, resultando num desgaste generalizado da restauração. Como tentativa de minimizar esses microdefeitos, alguns autores sugerem o uso de selantes de penetração superficial. Em vista disso, o propósito desse estudo foi avaliar a efetividade da ação de um seiante de penetração superficial (Fortify - Bisco) e de um agente de união (fornecido pelo fabricante do compósito) sobre a superfície polida dos compósitos odontológicos Tetric Ceram (Vivadent) e Z100 (3M), na rugosidade superficial, após desgaste por meio do ensaio de escovação mecânica. Foram confeccionados 144 corpos-de-prova (8mm de diâmetro por 2 mm de espessura), divididos em três grupos de 48 corpos-de-prova, de acordo com o intervalo de escovação, ou seja, seis meses ou um ano, além de um grupo sem escovação. Cada grupo foi dividido em 6 subgrupos de acordo com o tratamento superficial recebido, ou seja, sem tratamento, aplicação do agente de união do fabricante, e aplicação do Fortify. Após cada tratamento, foi feita a leitura da rugosidade superficial com um rugosímetro (Prazis Rug-03). Em seguida, os corpos-de-prova foram submetidos ao ensaio de escovação numa máquina (Equilabor) com velocidade constante de 250 ciclos por minuto, utilizando as escovas dentais Kolynos Doctor (Kolynos do Brasil) e o dentifrício Sorriso (Kolynos do Brasil). A rugosidade superficial foi então novamente medida As superfícies de duas amostras representativas de cada grupo foram cobertas com liga de ouro-paládio sob alto vácuo para a observação em microscopia eletrônica de varredura. Os resultados foram submetidos à análise de variância e ao teste de Tukey em nível de 5% de significância. Verificou-se que para o compósito Z100, os menores valores de rugosidade foram obtidos nas amostras tratadas antes do ensaio de escovação, tanto para as amostras que receberam ou não a aplicação de um agente de penetração superficial. Após o período de simulação de escovação de 6 meses e 1 ano, os valores de rugosidade aumentaram significantemente. Para o compósito Tetric Ceram, os resultados foram semelhantes aos do compósito 2100. As fotomicrografias mostraram que, em geral, após o ensaio de escovação pelo período de seis meses, o material de cobertura foi parcialmente removido, provocando aumento dos valores médios de rugosidade, que permaneceram ou diminuíram após 1 ano de escovacão / Abstract: Some microstructural changes in the surface of composites may be originated by mastigation and finishing and polishing procedures. These changes may grow continously through the superficial and subsuperficiai areas, resulting in a generalized restoration war. As an attempt to minimize these microdefects, some authors suggest the use of surface penetrating sealants. Based on this, the purpose of this study was to assess the efectiveness of the application of a surface penetrating sealant (Fortify - Bisco) and a bonding agent (provided by the manufacturer of the composite) on the polished surface of two dental composites, Tetric Ceram (Vivadent) and 2100 (3M), in surface roughness, after wear through mechanical toothbrushing. 144 specimens (8 mm in diameter, 2 mm in height) were manufactured, and they were divided in three groups of 48 specimens, according to a estimated period of toothbrushing, that is, six months and one year, and a group without toothbrushing. Each group was divided in three subgroups, according to the surface treatment received, that is, no treatment, application of the bonding agent of the manufacturer, and application of Fortify. After each surface treatment, a measurement of the surface roughness was made through a surface texture mechanism instrument (Prazis Rug-03). Following that, the specimens were submitted to toothbrushing in a machine (Equilabor) in constant speed of 250 strokes per minute, using Kolynos Doctor (Kolynos do Brasil) toothbrush and Sorriso (Kolynos do Brasil) toothpaste. The surface roughness was then measured one more time. The surface of two samples of each group were prepared for SEM (scanning electron microscopy) by being mounted on metal stubs and coated with a layer of gold-paladium. The results were subject to analysis of variance and to Tuke/s test at 5% significant level. It was shown that, regarding composite Z100, the samples treated before toothbrush ing - both the samples that received and did not receive the application of a surface penetrating agent - obtained the lowest values of roughness. After six months and one year of toothbrushing, the roughness values increased significantly. Regarding composite Tetric Ceram, the results were similar to composite Z100. The photomicrographs showed that generally, after a six-month period of toothbrushing, the cover material was partially removed, increasing the average value of roughness, which remained the same or decreased after one year of toothbrushing / Mestrado / Materiais Dentarios / Mestre em Odontologia
2

Avaliação in vitro da microinfiltração marginal em restaurações classe II utilizando diferentes tecnicas de inserção da resina composta condensavel

Casanovas, Rosana Costa 27 July 2018 (has links)
Orientadores : Giselle Maria Marchi Baron, Luiz Andre Freire Pimenta / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-27T21:04:08Z (GMT). No. of bitstreams: 1 Casanovas_RosanaCosta_M.pdf: 2671139 bytes, checksum: 49a86b76e273f9f804c328d6a384b208 (MD5) Previous issue date: 2001 / Resumo: Neste trabalho, estudou-se a influência de quatro diferentes técnicas de inserção da resina composta condensável fotoativada em cavidades de classe 11, no vedamento marginal, através de testes de infiltração de um agente corante. Foram realizadas 120 cavidades em dentes bovinos extraídos, com parede gengival localizada em dentinalcemento, sendo divididas, aleatoriamente, em 4 grupos (n = 30), de acordo com as técnicas restauradoras: Grupo 1- Inserção Única, Grupo 2- Inserção em Incrementos Horizontais, Grupo 3- Inserção em Incrementos Oblíquos e Grupo 4- Inserção Mista. As cavidades foram restauradas empregando-se o sistema adesivo (Prime & Bond 2.1 <B) e a resina composta (Surefil@). Após as restaurações serem polidas, os dentes foram submetidos à termociclagem (5:t2QC e 55:t2QC, durante 1000 ciclos) e, depois de adequadamente impermeabilizados, foram imersos em solução corante de azul de metileno a 2% pH 7 por 4 horas. Em seguida, os dentes foram cortados e avaliados quanto à microinfiltração na interface parede gengival/material restaurador, por dois examinadores, com auxílio de lupa estereoscópica (50x) e segundo um critério pré-estabelecido (escores de O a 4). O teste de Kruskal-Wallis demonstrou não haver diferença estatisticamente significante na microinfiltração entre as diferentes técnicas ao nível de significância de 5%. Nenhuma das técnicas restauradoras foi capaz de eliminar a microinfiltração em restaurações classe 11 em resina composta condensável com a margem gengival em dentinalcemento / Abstract: This work evaluated the influence of four different insertion techniques of light-cured condensable composite resin in class II restorations on marginal sealing by the mieroleakage tests of a dye agent. One hundred and twenty cavities were prepared in extracted bovine teeth with gingival wall located in dentine/cementum being randomly divided into four groups (n=30) according to the restorative techniques: group 1 - bulk insertion; group 2 - horizontal increments insertion; group 3 - oblique increments insertion and group 4 - mixed insertion. The eavities were restored with adhesive system (Prime & Bond 2.1 @) and composite resin (Surefil@). After the restoration had been polished, the teeth were submitted to a thermocycle proeess (5:t 22C and 55:t 22C during 1000 cycles) and properly impermeabilized, they were immersed in a dye solution of 2% Methylene Blue pH 7 for 4 hours. Following that proeess, the teeth were cut and evaluated for microleakage in gingival wall and restorative material interface by two examiners using a stereoseope magnifying glass (50x) with regard to previous criterion (0-4 seore). The Kruskal-Wallis test has showed no statistically significant difference in mieroleakage among different techniques in terms of 5% significance. No restorative technique was able to eliminate the mieroleakage in class 11 restorations with condensable composite resin in gingival margin located in dentine/cementum / Mestrado / Dentística / Mestre em Clínica Odontológica
3

Avaliação da infiltração de pigmentos na interface de restaurações dentais sob o efeito da termociclagem

Aguiar, Flávio Henrique Baggio, 1977- 02 February 2001 (has links)
Orientador : Jose Roberto Lovadino / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-27T21:08:26Z (GMT). No. of bitstreams: 1 Aguiar_FlavioHenriqueBaggio_M.pdf: 3722002 bytes, checksum: 882b7ffc7939bb985ee14bd715981a2f (MD5) Previous issue date: 2001 / Resumo: O objetivo deste estudo "in vitro" foi avaliar quantitativamente a infiltração marginal ao redor de restaurações dentais, realizadas com três compósitos de alta viscosidade, um compósito de média viscosidade, e amálgama de prata, e a possível influência da termocic1agem nos valores de infiltração. Para tanto, foram obtidos 100 blocos dentais, utilizando-se dentes humanos extraídos devido indicação ortodôntica e/ou cirúrgica. Através de uma ponta diamantada especial, foram preparadas cavidades cilíndricas medindo 1,85 :t 0,05 mm de diâmetro com 1,5 mm de profundidade. Esses blocos foram aleatoriamente divididos em dez grupos contendo 10 amostras. Cada grupo diferiu no tipo de material utilizado para a realização das restaurações, e na realização ou não da termocic1agem. Após a termocic1agem dos grupos designados para este teste, os blocos dentais restaurados de todos os grupo foram imersos em tubos de ensaio, separadamente, contendo o corante azul de metileno, por 12 horas. As amostras dentais foram lavadas e secadas. Um desgaste superficial de 0,05mm foi realizado na restauração, para remover uma possível camada do material restaurador que tenha sido pigmentada pelo corante. As amostras foram trituradas e imersas em tubo de ensaio, contendo álcool absoluto, para realizar-se a dissolução do corante. Os tubos de ensaio foram centrifugados e o sobrenadante da solução foi submetido à análise quantitativa de impregnação de corante, pelo aparelho de espectrofotometria. Os resultados foram lidos e interpretados através da análise estatística não paramétrica, pelos testes de Kruskal-Wallis e Mann Withman. Para os grupo não termocic1ados, as médias de infiltração foram (Jlg/ml): Amálgama ­ 4,279 (A); Solitaire - 4,148 (AB); P60 - 3,418 (ABC); Z250 - 3,184 (BC); SureFil­ 2,890 (C). Para os grupos tennociclados, as médias foram: Amálgama - 7,572 (A); Solitaire - 5,471 (A); 2250 - 4,330 (AB); P60 - 3,418 (BC); SureFil- 2,779 (C). Quando se analisou o efeito da tennociclagem, os resultados mostram não haver diferenças significativas entre os grupos submetidos ou não a termociclagem, para todos materiais / Abstract: The aim of this "in vitro" study was to evaluate quantitatively the microleakage on three high-density composite restorations, a medium-density one and amalgam restorations, with or without thennocycling. Sixty sound human molars freshly extracted for orthodontic or surgery reasons had their buccal and lingual faces sectioned into one hundred dental blocks. Cylindrical cavities of 1.85 :t 0.05 mm diameter by 1.5 mm depth were prepared with a special diamond bur. The blocks were randomly assigned to 10 test groups (n=lO). Each two groups were restored with a different material, and one of them was submitted to thennal stress. After thennocycling, the samples were immersed in methylene blue for 12 hours. Then, they were washed and dried. A 0.05 mm surface layer of the restorations was abraded to remove possible superficial die penetration in the restorative material. The samples were ground into powder and immersed in absolute alcohol, in order to dilute the methylene blue. They were centrifuged, and the floating solution was analyzed on a spectrophotometer to evaluate quantitatively the dye concentration. Results were statiscally analyzed by Kruskal- W allis test and Mann Withman test. For the non-thennocycled groups, the means of microleakage were (Ilg/ml): Amalgam - 4.279 (A); Solitaire - 4.148 (AB); P60 - 3.418 (ABC); Z250 - 3.184 (BC); SureFil - 2.890 (C). For the thennocycled groups, the means were: Amalgam - 7.572 (A); Solitaire - 5.471 (A); Z250 - 4.330 (AB); P60 - 3.418 (BC); SureFil- 2.779 (C). The thennocycling analysis presented no statistical significant differences among the themocycled and non-thennocycled groups, for each material tested. / Mestrado / Dentística / Mestre em Clínica Odontológica
4

Avaliação da microinfiltração marginal e da dureza de restaurações classe II de resina composta, utilizando dois sistemas de polimerização e duas tecnicas restauradoras

Amaral, Cristiane Mariote 29 March 2001 (has links)
Orientador : Luiz Andre Freire Pimenta / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-27T20:51:30Z (GMT). No. of bitstreams: 1 Amaral_CristianeMariote_M.pdf: 3974434 bytes, checksum: 2be4fe083fa514a705f8f2a2e0b3902d (MD5) Previous issue date: 2001 / Resumo: O objetivo deste trabalho foi avaliar a microinfiltração marginal e a dureza de restaurações classe II de resina composta, usando duas técnicas restauradoras e dois sistemas de polimerização. Foram preparadas 120 cavidades simulando classe II em dentes bovinos, que foram divididas em 4 grupos: DEME 1 - único incremento + polimerização convencional (Optilux 500/DEMETROM); DEME 3 - incrementos vestíbulo-linguais + polimerização convencional; SOFT 1 - único incremento + polimerização soft-start (Degulux Soft-Start/DEGUSSA); SOFT 3- incrementos - vestíbulo-linguais +polimerização soft-start. Todas as cavidades foram restauradas com o sistema Single Bondl ZlOO (3M). Após a termociclagem (1000 ciclos a 5 e 55 °c), os dentes foram imersos em solução de azul de metileno a 2%, por 4 horas, e a microinfiltração foi avaliada. Metade das amostras foi incluída em resina de poliestireno, polida e a microdureza Knoop foi mensurada. Quanto à microinfiltração, o Teste Exato de Fisher mostrou diferença estatisticamente significante entre os grupos (p<0,05). Não foi encontrada diferença estatisticamente significante (ANOV A) na dureza entre todos os grupos, em qualquer profundidade. A técnica incremental exibiu menor infiltração marginal, independente do sistema de polimerização utilizado. O sistema soft-start promoveu polimerização semelhante ao convencional, mas não melhorou o selamento marginal / Abstract: The aim of this study was to evaluate the marginal microleakage and the microhardness of class II composite resin restorations using two restorative techniques and two polymerization systems. One hundred twenty class II cavity were prepared in bovine teeth and it were randomly divided into four groups: DEME 1- Bulk increment + conventional polymerization (Optilux 500/DEMETROM); DEME 3- Bucco-lingual increments + conventional polymerization; SOFT 1- Bulk increment + soft-start polymerization (Degulux Soft-StartlDEGUSSA); SOFT 3- Bucco-lingual increments + soft-start polymerization. All cavities were restored with the ZlOO/Single Bond system (3M). After thermocycling (1000 cycles at 5 °C and 55°C), the samples were immersed in methilene blue 2% dye solution, for 4 hours, and the microleakage was evaluated. Half of samples was embedded in polyester resin, polished and the Knoop microhardness was measured. Fisher Exact test showed statistical significant difference of microleakage among groups (p<0,05). No statistical differences (ANOV A) were found for hardness for all groups at any depth. Incremental technique showed less leakage, regardless of the polymerization systems used. The soft-start system provided polymerization similar to conventional system, but could not improved the marginal sealing / Mestrado / Dentística / Mestre em Clínica Odontológica
5

Avaliação "in vitro" da infiltração marginal em restaurações de resina composta em cavidades classe II utilizando diferentes combinações restauradoras

Castro, Ana Karina Barbieri Bedran de 29 March 2001 (has links)
Orientador : Luiz Andre Freire Pimenta / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-27T21:06:54Z (GMT). No. of bitstreams: 1 Castro_AnaKarinaBarbieriBedrande_M.pdf: 3358547 bytes, checksum: f08d2334343db4f45a8c783fca6a268f (MD5) Previous issue date: 2001 / Resumo: O objetivo deste trabalho, "in vitro", foi avaliar qualitativamente, através da penetração de corante, dois sistemas restauradores, e o efeito de uma camada intermediária de resina composta de baixa viscosidade. Foram selecionados 90 dentes bovinos, os quais tiveram parte da coroa seccionada a fim de padronizar comprimento de 4 mm no sentido ocluso-gengival. Em seguida, foram realizados preparos cavitários padronizados, nas faces mesial e distal, simulando classe II tipo "slot" vertical, com término em dentina, totalizando 180 preparos. As cavidades foram aleatoriamente divididas em 6 grupos (n=30): Gl- sistema adesivo Etch & Prime 3.0 (EP) (Oegussa) + resina "compactável" Oefinite (OEF) (Oegussa); G2- sistema adesivo Prime & Bond NT (PB) (Oentsply) + OEF; G3- EP + resina "flow" Wave (W) (SOl) + OEF; G4- PB + resina composta TPH Spectrum (TPH) (Oenstply); G5- EP + TPH; G6- PB + W + TPH. Após o acabamento e polimento, os espécimes foram submetidos a 1500 ciclos térmicos em banhos de 5 :t 2°C e 55 :t 2°C, com duração de 60 segundos para cada banho. Após ciclagem térmica, os dentes foram vedados com esmalte de unha e imersos em solução de azul de metileno a 2%, durante 4 horas. Em seguida, foram realizados seccionamentos ao meio das restaurações e analisadas qualitativamente em lupa estereoscópica (45X), seguindo um padrão de escores em dentina (O a 4). Também foi avaliado o padrão de infiltração (adesivo ou dentinário) dos espécimes que infiltraram. Os dados foram submetidos ao Teste Kappa de reprodutibilidade interexaminadores, e a média dos escores dos 3 examinadores foi analisada pelo Teste não-paramétrico de Kruskall-Wallis e Teste não-paramétrico de Comparação Múltipla com p<0,05. O padrão de infiltração foi analisado pelo Teste Exato de Fisher. Os postos médios dos grupos foram dispostos em ordem crescente dos valores: G4-6723(a). G3- 7258 (ab). G6- 7843 (ab). G5- 93 19 (be). G2- 11297 (e). Gl- 11352 (e) Conclui-se que nenhum dos sistemas utilizados foi capaz de impedir a microinfiltração, e o uso de uma resina "flow" reduziu os valores de infiltração para a resina OEF. O padrão de infiltração para os grupos que utilizaram PB foi dentinário, apresentando-se predominantemente adesivo para EP / Abstract: The purpose of this study was to evaluate the "in vitro", marginalleakage, with dye penetration, of two restorative systems and the application of a flowable composite resin as an intermediate layer. Ninety bovine teeth were selected and had part of the crown sectioned allowing a standardization of 4 mm of height from ocluso-gengival proximal margins. Standardized cavities preparations simulating class 11 type box were design with gingival margin at dentin, on mesial e distal faces. The cavities were randomly divided in 6 groups (n=30): G1- adhesive system Etch & Prime 3.0 (EP) (Oegussa) + Oefinite composite resin (OEF) (Oegussa); G2- adhesive system Prime & Bond NT (PB) (Oentsply) + OEF; G3- EP + Wave flowable resin (W) (501) + DEF; G4- PB + TPH Spectrum composite resin (TPH) (Oenstply); G5- EP + TPH; G6- PB + W + TPH. After finishing and polishing, the specimens were subjected to 1500 thermal cycles in bath of 5 :i: 2°C e 55 :i: 2°C with 60 seconds dwell time each bath. After thermocycling, the specimens were sealed with nail vamish and immersed for 4 hours in a 2% solution of methylene blue. Than the specimens were sectioned longitudinally through the center of the restoration and qualitatively evaluated by stereomicroscopy (45X), following a ranked score for dentin margin (O a 4). The leakage partem (adhesive or dentin) was also evaluated for those specimens that had leakage. The data were subjected to a reproducibility Kappa T est and the mean of the 3 examiners scores were analyzed by Kruskall-Wallis non-parametric Test and multiple comparison non-parametric Test (p<0.05). For leakage partem Fisher Exact Test was used. The ranked values of the groups were expressed in decreasing order: G4- 67.23 (a); G3- 72.58 (ab); G6- 78.43 (ab); G5- 93.19 (be); G2- 112.97 (e); G1- 113.52 (e). It was concluded that all systems used were not able to impede the microleakage, and the use of a flowable resin decrease the values of leakage for the resin OEF. The partem of leakage for the groups that used PB was at dentin, showing mostly adhesive to EP / Mestrado / Dentística / Mestre em Clínica Odontológica
6

Alteração de cor de resinas compostas imersas em diferentes meios liquidos

Freitas, Francisco Jose Guimarães de, 1962- 14 July 2018 (has links)
Orientador : Oreste Benatti / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-14T01:25:38Z (GMT). No. of bitstreams: 1 Freitas_FranciscoJoseGuimaraesde_M.pdf: 3030969 bytes, checksum: 2843f82a83ed20a142556aeef2632757 (MD5) Previous issue date: 1989 / Resumo: O presente trabalho teve por objetivo principal avaliar as alterações de cor de 3 resinas compostas, imersas em diferentes meios líquidos, por um período de tempo não superior a 30 dias. Visou, também, buscar uma possível correlação entre essas alterações e fatores, tais como: concentração, tamanho das partículas de carga e pH dos meios a que estavam expostos os materiais. Os registros. das alterações de cor, a intervalos de tempo diferentes, foram feitos através de fotomicrografias. Os resultados analisados permitiram concluir que: (1) corpos de prova representativos de resinas compostas' convencionais, quando submetidos aos procedimentos de acabamento e polimento, tornam-se mais suscetíveis à descoloração d.oque os com pó si tos com micropartículas. , (2) os ácidos orgânicos, presentes nas soluções antissépticas, parecem ter atacado a superfície dos compósitos, principalmente nos primeiros 7 dias de estudo, favorecendo, ainda mais, sua descoloração; (3) a concentração das partículas de carga parece não contribuir tanto para a descoloração do material, quanto o faz o seu tamanho. Tal fato foi, aqui, comprovado pela menor descoloração apresentada pelo Herculite em relação ao Adaptic / Abstract: The present study was carried out to evaluate the color change of three different composite resins, after being immersed in some antiseptical solutions for a period of time not over 30 days. .It was also the aim of the present study to search for a correlation between these alterations and factors, such as: concentration, size of the fillers and pH of the solutions to which the specimens were.exposed. The registers oÍ the color alterations were taken through photomicrographs at ifferent intervals of time. The results, once analysed, haveshown that: (1) specimens representing conventional composte resins, become more sensitive to color change after usual finishing and polishing proceduresi (2) organic acids, present in the antiseptical solutions, seem,to have attacked the composite surface, mainly on the first seven daysof study, which contributed alI the more to its discolorationi (3) the filler concentration, when compared with its size, doesn't seem to produce an outstanding discoloration of the composite. Such a fact was, here, confirmmed by the smallest discoloration presented by Herculite in relation to Adaptic / Mestrado / Materiais Dentarios / Mestre em Odontologia
7

Estudo da rugosidade, pigmentação e da relação entre ambas nas superficies de compositos tratadas com diversos sistemas de acabamento e polimento

Lovadino, José Roberto, 1953- 24 July 2018 (has links)
Tese (livre-docencia) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-24T00:14:49Z (GMT). No. of bitstreams: 1 Lovadino_JoseRoberto_LD.pdf: 3449328 bytes, checksum: b1898409a8af1238fb9ea2f6e7b3fce1 (MD5) Previous issue date: 1997 / Resumo: Neste trabalho verificamos a rugosidade superficial, a suscetibilidade à deposição superficial de corante e a correlação entre estes dois fatores, quando a superfície de três compósitos (Adaptic, TPH e Herculite XRV) foram submetidas ao acabamento e polimento realizados com discos-de-lixa Sof-Lex (3M), Pontas Diamantadas (KG-Sorensen) e Pontas de Borracha Abrasiva (KG-Sorensen). Realizamos a análise da rugosidade da superfície com um rugosímetro (Praxis) e a suscetibilidade à deposição superficial de corante através de um método de espectrofotometria (Beckmam). Os resultados foram submetidos à análise estatística, não paramétrica, peio do teste de Kruskal-Wallis. Verificamos que os mesmos tratamentos produziram superfícies com valores de rugosidade (Ra) semelhantes para todos os materiais; que um mesmo material pode apresentar valores de Ra diferentes, quando submetidos aos diferentes tratamentos, e que o tratamento realizado com os discos-de-lixa Sof-Lex apresentou os menores valores de Ra e o realizado com Pontas Diamantadas, os piores. Também verificamos que os diferentes compósitos podem apresentar suscetibilidade semelhante à deposição superficial de corante, independentemente do tratamento utilizado; que os diferentes tratamentos empregados, num mesmo compósito, podem produzir superfícies com diferentes suscetibilidades e que o tratamento realizado com discos-de-lixa Sof-Lex produziram superfícies menos suscetíveis. Não foi verificada uma correlação confiável entre os valores de Ra e a suscetibilidade à deposição superficial de corante / Abstract: This study was verified the roughness, stain over composites surfaces and the relationship between of both when three finish/polishing techniques was applied. The surface analysis was obtained with a perfilometer and spectrophotometer method. The data was analysed by Kruskal-Wallis test. The statistical analysis showed that the same finish/polishing technique produced different scores of roughness (Ra) over the composites surfaces; that the same composite submited at different finish/polishing techniques could show different scores of Ra; that the best finish/polishing technique was obtained with the Sof-Lex discs and with Diamond Points the worse. Different composites could produced equivalent stain scores independently of finish/polishing techniques; different finish/polishing techniques could produced different stain level over the surface of the same composite; Sof-Lex discs produced, except for TPH composite, the minor stain level. There wasn't a direct relationship between roughness and stain levels / Tese (livre-docencia) - Univer / Livre docente em Odontologia
8

Avaliação dos procedimentos de acabamento e polimento sobre a rugosidade superficial de resinas compostas

Ono, Rosana 23 June 1995 (has links)
Orientador: Simonides Consani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-20T10:59:33Z (GMT). No. of bitstreams: 1 Ono_Rosana_M.pdf: 4255967 bytes, checksum: beac92cd6b873a75eec9adb61e7fe7f1 (MD5) Previous issue date: 1995 / Resumo: o propósito do presente trabalho foi avaliar "in vitro" a rugosidade superficial dos compósitos Herculite XR V (Sybron/Kerr), Z 100 (3M Co.) e Tetric (Vivadent), submetidos a diferentes procedimentos de acabamento e polimento. Foram confeccionados 24 corpos de prova de cada material, com 8mm de diâmetro por 2mm de espessura; o preenchimento da matriz foi incremental, com exposição individual de 60 segundos, com. fotopolimerizador Visilux 2 (3M). Após o procedimento total de polimerização, os corpos de prova foram removidos da matriz e armazenados, em estUfa, a 37° C e umidade relativa de 100% por 24 horas. Após este período de tempo, cada grupo de amostras foi submetido aos procedimentos de acabamento e polimento com diferentes tipos de materiais abrasivos. Cada procedimento de acabamento e polimento foi realizado por aproximadamente 2 minutos, respectivamente com auxílio do aparelho de alta velocidade de rotação (Turbina- DABI ATLANTE), refrigerados com jatos de água/ar, com movimentos lineares em uma única direção, e contra-ângulo (Micromotor DABI ATLANTE) em baixa velocidade de rotação, à seco. As superficies das amostras foram avaliadas antes e após cada procedimento e a leitura considerada foi a média aritmética entre os picos e vales (Ra), percorrida pelo perfilômetro (Prazis-Rug 3-Argentina), num trecho de 4,8mm. De acordo com os resultados, os procedimentos de acabamento com brocas de 30 lâminas e polimentos com Abrasivos de silicone Viking (cinza e verde) + Gel, discos Sof-Lex (fino e extrafino) e Enhance + Prisma Gloss produziram índices de rugosidade sem diferença estatisticamente significativa sobre Herculite XRV, Z 100 e Tetric. Os procedimentos de acabamento com pontas diamantadas F e FF e polimentos com Abrasivos de silicone Viking (cinza e verde) + Gel apresentaram índices de rugosidade com diferença estatisticamente significativa quando comparados aos polimentos com discos Sof-Lex (fino e extrafino) ou Enhance + Prisma Gloss, sobre I Herculite XR VeZ 100. Observou-se também que os procedimentos de acabamento com pontas diamantadas e polimentos com Abrasivos de silicone Viking (cinza e verde) + Gel, discos Sof-Lex (fino e extrafino) e Enhance não apresentaram diferenças estatisticamente significativas sobre o compósito Tetric / Abstract: The purpose of this study was to evaluate the in vitro surface roughness of Herculite XR V, Z 100 and T etric composite samples, subjected to different finishing and polishing procedures. A set of twenty-four 8mm diameter, 2mm thick samples was prepared for each studied material, using the incremental technique for mold filling. A sixty-second exposure to visible light was necessary to set the samples. The activating unit used was Visilux 2 (3M). After setting, the samples were stored in an oven, at 37°C and 100% relative humidity for 24 hours. Afterwards, each group of samples was subjected to the finishing and polishing procedures with different types of materials and abrasives. E,ach finishing and polishing procedure lasted approximatel y 2 minutes. The finishing procedure was carried out with the aid of an air-water spray, high speed handpiece, moved straight on a one and on1y direction. An air-cooled, low-speed handpiece was used for the polishing procedures. The surfaces of the samples were evaluated before and after each procedure and the reading that was ~sed was the arithmetic mean value between the peaks and valleys scanned by the surface t According to t he results, the finishing procedures with 30 blade burs, and polishing with Viking (grey and green) silicone abrasives + gel, Sof Lex (fine and extra-fine) discs and Enhance + Prisma Gloss, have produced roughness indexes without significant statistical differenceS for Herculite XRV, Z 100 and Tetric. The finishing procedures with F and FF diamond points and polishing procedures with Viking (grey and green) silicone abrasives + gel showed roughness indexes with significant statistical differences when compared to the polishing procedures with Sof- Lex (fine and extra-fine) disks or Enhance + Prisma Gloss, for Herculite XRV and Z 100. It has also been observed that the finishing procedures with diamond points and polishing procedures with Viking (grey and green) silicone abrasives + gel, I Sof-Lex (fine and extra-fine) disks and Enhance + Prisma Gloss didn't show significant statistical differences for Tetric composite / Mestrado / Materiais Dentarios / Mestre em Ciências
9

Compatibilidade biologica da resina resorcina-formaldeido : avaliação histologica de seus efeitos em tecidos subcutaneo e dentina de ratos

Costa, Carlos Alberto de Souza 17 July 2018 (has links)
Orientador: Jose Merzel / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-17T08:45:22Z (GMT). No. of bitstreams: 1 Costa_CarlosAlbertodeSouza_M.pdf: 6465518 bytes, checksum: 68c4118b1685164e19be9f7c232211ac (MD5) Previous issue date: 1992 / Resumo: A biocompatibilidade de uma resina composta de resorcina e formaldeído foi estudada através de implantes subcutâneos e aplicação em cavidades dentais de ratos. Os implantes foram feitos através de tubos de polietileno preenchidos com resina - polimerizada ou estado pastoso ¿ inseridos em bolsas cirúrgicas no dorso dos animais. Em cavidades preparadas em primeiros molares superiores, a do lado esquerdo foi preenchida pela resina e polimerizada e a do lado direito, usada como controle, foi forrada com hidróxido de (Dycal) e restaurada com amálgama. Os animais foram sacrificados em períodos pós-operatórios de 7, 15, 30 e 60 dias. Cortes de pele ou de dentes incluídos em parafina foram corados com H.E. e revelaram no caso do tecido subcutâneo, um intenso infiltrado inflamatório e necrose nos períodos iniciais e tendência a reparação nos períodos posteriores com a formação de uma cápsula fibrosa isolando a resina. Sempre que houve extravasamento de resina, o que ocorreu com maior freqüência quando implantada em estado pastoso, houve uma intensa reação de células gigantes ao redor do material. No caso do material aplicado em cavidades com uma barreira de dentina entre a resina e a polpa, a reação inflamatória nesta última foi geralmente acompanhada de dentina reacional. Na maioria dos casos a formação de dentina reacional foi intensa, chegando por vezes a obliterar a cavidade pulpar do primeiro molar e em alguns casos também, em grau decrescente, as cavidades pulpares dos segundos e terceiros molares do mesmo lado. Como este quadro ocorreu também em um caso controle, isto foi interpretado como um efeito traumático causado por excesso de material, uma vez que a resina não pode ser esculpida. Os resultados sugerem que a resina, desde que haja uma barreira dentinária, tem sobre o tecido pulpar uma reação discreta / Abstract: The biocompatibility of a resorcin-formaldehyde resin was studie after subcutaneous implantation and filling of dental cavities in rats. The implants were done with poliethylene tubes filled with the resin, polimerized or as paste, and inserted into dorsal surgical pockets. Cavities were prepared in the upper first molars, beign left one filled up with the resin and polimerized; the rigth one, used as control, received pupa protection with calcium hydroxide cement (Dycal) and was restored with amalgam. The animals were sacrificed 7, 15, 30 and 60 days after these procedures... Note: The complete abstract is available with the full electronic digital thesis or dissertations / Mestrado / Patologia / Mestre em Ciências
10

Avaliação da microdureza e cor de cimentos resinosos inseridos em diferentes substância e PH

Santos Neto, Cássio dos January 2014 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2014 / Made available in DSpace on 2015-02-05T20:18:07Z (GMT). No. of bitstreams: 1 329721.pdf: 4532649 bytes, checksum: 18cb60d2e542b0328ffc57d72577675e (MD5) Previous issue date: 2014 / O objetivo deste estudo in vitro foi de avaliar a microdureza e a alteração da cor de quatro cimentos resinosos, imersos em seis diferentes substâncias e por diferentes períodos de tempo. Sessenta discos de cimentos resinosos, foram confeccionados (6mm x 2mm), para cada tipo de cimento (Rely - X Veneer (R), Rely-X U200 (U) , Multilink (M) e o Variolink Veneer (V)) e polidos com ponta de borracha de passo único (Optrapol, Ivoclar Vivadent) por 30 s, em seguida armazenados por 24 hrs em água destilada. A subdivisão foi realizado em 6 subgrupos (n=10), de acordo com a solução imersora, a uma temperatura de 37ºC: Grupo R-1(Rely-X Veneer), Grupo M-1 (Multilink), Grupo V-1 (Variolink Veneer) e o Grupo U-1(Rely-X U200), foram armazenadas em água destilada (controle (1)). Grupo R-2, M-2, V-2 e U-2 em coca (2). Grupo R-3, M-3, V-3 e U-3 em vinho (3), Grupo R-4, M-4, V-4 e U-4 em suco cítrico (4), Grupo R-5, M-5, V-5 e U-5 em whisky (5) e Grupo R-6, M-6, V-6 e U-6 embebida energética (6). Os espécimes foram mesurados imediatamente, 24 hrs, 7, 14 e 90 dias, por um microdurometro (HMV 2, Shimadzu - Japão) e a cor avaliada por um espectrofotômetro (Easyshade, Vita). Para a análise estatística dos dados, foi empregada a análise de variância multiplas, (ANOVA) e o teste de tukey ao nível de 95% de confiança. Os maiores valores de microdureza foram obtidos no baseline, seguido de 7, 14 e 90 dias. Apenas não houve diferença estatisticamente significante entre os tempos de 24 horas, 7 e 14 dias(p>0,05). Para os valores de 90 dias, ocorreu uma queda acentuada dos valores para a microdureza. Quando observados os espécimes submersos em água, nota-se alteração no armazenamento de 90 dias, mas sem diferença estatística. O líquido que promoveu o maior índice de alteração de cor foi o vinho nos grupos: R3, M3, V3 e U3. Esses dados prevaleceram em todos os cimentos testados, a partir do 7° dia de armazenamento. O /\E, não foi alterado para os grupos, que foram imersos em água. Os líquidos coca-cola, suco cítrico, whisky e energético, tiveram alteração significativa aos 90 dias de armazenamento. O grupo que apresentou a menor variação após os 14 dias foi o cimento resinoso Rely - X Veneer, porém sem diferença estatística. As substâncias nas quais os cimentos resinosos foram imersos, apresentaram influência na microdureza superficial e na cor para todos os cimentos testados, diminuindo a estabilidade de cor e a dureza em períodos mais longos.<br> / Abstracts: The aim of this in vitro study was to evaluate the microhardness and color change four resin cements immersed in six different substances and for different periods of time. Sixty discs of resin cements were cut (6mm x 2mm), for each type of cement (Rely X -Veneer (R), Rely-X U200 (U), Multilink (M) and Variolink Veneer (V)) and polished rubber tipped single step (Optrapol, Ivoclar Vivadent) for 30 s, then stored for 24 hrs in distilled water. The subdivision was carried out in six subgroups (n = 10) according to imersora solution at a temperature of 370C: R 1-group (Rely-X Veneer)-1 Group M (Multilink), GroupV-1 (Variolink Veneer) and the U-1 group (Rely-X U200) were stored in distilled water(control) (1). Group R-2, M-2, M-2 and U-2 cocaine (2). Group R-3, M-3, M-3 and H-3 'wine(3)-R 4 group, M-4, M-4 and U-4 as citric juice (4)-R 5 group, M-5, M-5 and H-5 whiskey (5)group R-6, F-6, V-6 and U-6 in the energy drink (6). The specimens were immediately mesurados, 24 hrs, 7, 14 and 90 days, by a microhardness (HMV 2, Shimadzu - Japan) and the color measured by a spectrophotometer (Easyshade, Vita). For statistical analysis, we used the multiple analysis of variance (ANOVA) and Tukey's test at 95% confidence.The highest microhardness values were obtained at baseline, followed by 7, 14 and 90 days. As there was no statistically significant difference between the times of 24 hours, 7 and 14 days (p> 0.05). For values of 90 days, there was a sharp decline in values for microhardness. When observing the specimens submerged in water, there is change in storage of 90 days, but no statistical difference. The liquid that promoted the highest rate of color change was the wine groups: R3, M3, V3 and U3. These data prevailed in all cements tested, from the 7th day of storage. The /\E, has not changed for the groups, which were immersed in water. Net cola, citrus juice, whiskey and energetic, had significantly after 90 days of storage change. The group that had the lowest variation after 14 days was the resin cement Rely X - Veneer, but without significant differences.

Page generated in 0.0586 seconds