531 |
Influência da diabetes mellitus na resposta tecidual e na capacidade de mineralização dos cimentos Sealapex, MTA Angelus e MTA Fillapex /Queiroz, Índia Olinta de Azevedo. January 2013 (has links)
Orientador: João Eduardo Gomes Filho / Banca: Luciano Tavares Ângelo Cintra / Banca: Mário Tanomaru Filho / Resumo: O objetivo deste estudo foi avaliar a influência da diabetes mellitus na resposta tecidual e na capacidade de mineralização dos cimentos Sealapex®, MTA Angelus® e MTA Fillapex®. Vinte e quatro ratos Wistar foram divididos em dois grupos: diabéticos e não diabéticos. A indução de diabetes foi feita por meio da aplicação do Aloxano. Cada animal recebeu três implantes de tubos de polietileno contendo os materiais a serem testados e mais um tubo vazio como controle. Seis animais de cada grupo receberam injeções dos fluorocromos Calceína (7º dia), Alizarina (14o dias) e Oxitetraciclina (21o dias) durante a fase experimental. Os tempos operatórios foram 07 e 30 dias, quando os animais foram mortos e os espécimes processados para análise histológica de hematoxilina e eosina, Von Kossa, luz polarizada e fluorescência. Resultados: No 7o dia, observou-se uma resposta inflamatória moderada entre todos os grupos e no 30o dia, verificou-se uma resposta inflamatória leve. Ambos os grupos diabético e não diabético apresentaram, aos 07 e 30 dias, com todos os materiais testados áreas de mineralização e estruturas birrefringentes à luz polarizada. Sealapex® e MTA Fillapex® apresentaram uma maior intensidade de fluorescência do que MTA Angelus® (p <0,05) para todos os fluorocromos no grupo não diabético e somente para alizarina e oxitetraciclina no grupo diabético. Não houve diferença entre o Sealapex® e o MTA Fillapex® para nenhum fluorocromo independente da condição diabética. A intensidade de fluorescência não se alterou com nenhum material nos ratos diabéticos. Conclusão: A diabetes mellitus não interferiu na resposta tecidual e na capacidade de mineralização do Sealapex®, MTA Angelus® ou MTA Fillapex® / Abstract: Objective: The aim of this study was to evaluate the influence of diabetes mellitus on tissue response and mineralization ability of Sealapex® MTA Angelus® and MTA Fillapex® sealers. Methods: Twenty-four Wistar rats were divided into two groups: diabetics induced by Alloxan and non-diabetics. The materials were placed in the polyethylene tubes and implanted into dorsal connective tissue of rats for 7 and 30 days. Six animals from each group received injection with calcein on day 7, alizarin on day 14 and oxytretacycline hydrochloride on day 21. The animals were killed after 7 and 30 days and the specimens were prepared for histologic analysis with hematoxylin and eosin, Von Kossa technique, and not stained for polarized light or fluorescence. Results: On 7 days, it was observed similar inflammatory reactions among all groups characterized by a moderate inflammatory response and on 30 days, it was found a mild inflammatory response. Both materials groups exhibited positive structures on Von Kossa and Polarized light analysis either on 7 and 30 days. Sealapex® and MTA Fillapex® showed more fluorescence intensity than MTA Angelus® (p<0.05) for all fluorochromes in non-diabetic group and for alizarin and oxytretacycline in diabetic group. It was not observed difference between Sealapex® and MTA Fillapex® for all fluorochromes independently on the diabetic condition. Fluorescence intensity was not changed with any material in diabetic rats. Conclusion: It was concluded that diabetes mellitus did not influence the tissue response or mineralization stimulated by Sealapex® or MTA Angelus® or MTA Fillapex® / Mestre
|
532 |
Verificação da dureza de gessos em função da compatibilidade com materiais de moldagem à base de borracha /Araujo, Rosehelene Marotta. January 1986 (has links)
Orientador: Francisco Pedro Monteiro da Silva Filho / Resumo: O material mais empregado atualmente na construção de modelos é o gesso, que a par de técnica simples reúne condições bastante satisfatórias com relação às propriedades mecânicas, físicas e químicas. Porém, a compatibilidade relativa dos gessos com os materiais de moldagem pode comprometer as qualidades da superfície do modelo. Em nosso trabalho, estudamos a Dureza de dois tipos de gessos: tipo III (gesso pedra) e tipo IV (gesso pedra melhorado), bem como a influência do contacto com três tipos de materiais de moldagem: silicone polimerizada por condensação (Xantopren), polissulfeto (Permlastic) e silicone polimerizada por adição (Provil). Como parâmetro de comparação foi utilizado o gesso reagindo em contacto com uma superfície de vidro...... ( (Resumo completo , clicar acesso eletrônico abaixo) / Abstract: Currently the most widespread material used in dies is gypsum that together with its simple technique has very satisfactory mechanical, chemical and physical properties. However, its compactibility with the impression materials can compromise the die surface quality. In our work, we studies the hardness of the two gypsum types: Type III (die stone) and type IV (improved die stone), as well as the influence of the contact with three types of impression materials: polymerized silicone for condensation (Xantopren), polysulfide (Permlastic) and polymerized silicone by addition (Provil). As comparison parameter gypsum was used in contact with a glass surface…(Complete abstract click electronic access below) / Mestre
|
533 |
Efeito do envelhecimento In Vitro na transformação de fase cristalina da Y-TZP : análise topográfica, mecânica e cristalográfica /Arata, Anelyse. January 2012 (has links)
Orientador: Rubens Nisie Tango / Coorientador: Guilherme de Siqueira Ferreira Anzaloni Saavedra / Banca: Rubens Nisie Tango / Banca: João Paulo Barros Machado / Banca: Tarcísio José de Arruda Paes Junior / Resumo: A literatura mostra escassez de informações sobre o envelhecimento de cerâmicas Y-TZP de uso odontológico. O objetivo deste estudo foi o de avaliar o efeito do envelhecimento in vitro inicial em autoclave e avaliar a curva cinética de transformação de fase através do envelhecimento em reator hidrotérmico pressurizado em zircônia odontológica (Y-TZP). Especificamente: a - identificar o início da degradação, b - avaliar a resistência mecânica após envelhecimento inicial em autoclave, ccomparar diferentes métodos de leitura quanto à transformação de fase e análise topográfica, d - determinar a cinética de cristalização isotérmica por meio do envelhecimento em reator, e -comparar os métodos de quantificação a partir da equação de Garvie e Nicholson e o método de Rietveld. Discos de zircônia (12mm Ø x 1,2mm em espessura) foram divididos em grupos: A) envelhecido em autoclave (n=10); B) envelhecido em reator (n=4). O grupo A foi submetido ao envelhecimento em autoclave (134 oC, 2 bar), em tempos de 6, 15, 30, 42, 60, 90, 144, 198, 240, 300 e 360 minutos. O grupo B foi submetido ao envelhecimento em reator (130 oC, 2 bar), em tempos de 6, 8, 10, 12, 14, 20, 30, 40, 48, 60, 84, 108 e 138 horas. A caracterização superficial e cristalográfica foi realizada antes e depois em microscopia de força atômica (MFA), Perfilometria óptica, Difração de Raios-X e, também foram realizadas análises em microscopia eletrônica de varredura (MEV) e Raman. O grupo envelhecido em autoclave foi submetido ao teste de flexão biaxial. Os valores de Ra (nm) obtidos em Perfilometria Óptica, os valores de resistência (MPa) e os valores de transformação de fase cristalina t-m (%) foram submetidos à análise de variância de 1 fator e ao teste de Tukey... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The literature shows a lack of information about Y-TZP aging of dental ceramics. The aim of this study was to evaluate the initial in vitro aging effect and evaluate the kinetic curve of phase transformation through the pressurized hydrothermal reactor of dental zirconium. Specifically: a- the identification of the beginning of degradation; b- evaluation of the mechanical resistance after steam aging; c- compare different methods of phase transformation and topographic analysis, d- determine the kinetic of crystallization through the reactor; e- compare the phase quantification methods between the Garvie and Nicholson equation and Rietveld Method. Discs of zirconium (12mm Ø x 1,2mm thickness) were divided in groups: A) steam aged (n=10); B) Hydrothermal reactor aged (n=4). The group A was submitted to water steam aging (134 oC, 2 bar) for 6, 15, 30, 42, 60, 90, 144, 198, 240, 300 and 360 minutes. The group B was submitted to reactor aging (130 oC, 2 bars), for 6; 8; 10; 12; 14; 20; 30; 40; 48; 60; 84; 104 and 138 hours. The surface and crystallographic characterization before and after aging were made using atomic force microscopy (AFM), Optical Profilometry, X-ray diffraction (DRX), scanning electron microscopy (SEM) and Raman spectroscopy. The steam aged group was submitted to biaxial flexure test. The values of Ra (nm) obtained by optical profilometry and the crystalline phase transformation values t-m (%) were submitted to One Way ANOVA and Tukey test(α=0,05). A gradual increase was observed at the monoclinic phase concentration as the time increased and in the same way the roughness values increased. The resistance values demonstrated a tendency to decrease with the increase of aging time. The group aged by the reactor presented the increase of monoclinical phase reaching 60% of saturation through... (Complete abstract click electronic access below) / Mestre
|
534 |
Avaliação da união zircônia-cimento resinoso-dentina com diferentes estratégias de cimentação e de envelhecimento /Castro, Humberto Lago de. January 2013 (has links)
Orientador: Alvaro Della Bona / Co-orientador: Tarcísio de Arruda Paes Júnior / Banca: Alberto Noriyuki Kojima / Banca: Lucas Villaça Zogheib / Banca: Vanessa Cruz Macedo / Resumo: Objetivou-se avaliar o efeito de métodos de envelhecimento na resistência adesiva ( σ) de três sistemas de cimentação resinosa de ativação dual (RXA- RelyX ARC, RXU- RelyX U100 e PF- Panavia F) entre a dentina e uma cerâmica à base de zircônia estabilizada por óxido de ítrio (In-Ceram YZ, Vita Zanhfabrik) com diferentes tratamentos de superfície. A superfície dentinária oclusal de 72 molares humanos hígidos foi exposta e condicionada conforme as instruções dos fabricantes. Os blocos cerâmicos (72) foram cortados, planificados, sinterizados e divididos em dois grupos conforme o tipo de tratamento de superfície: PA- jateamento com óxido de alumínio (≤ 45μm) ou SC- silicatização (Rocatec Soft, 3M ESPE). A cimentação dos blocos cerâmicos foi realizada de acordo com as instruções dos fabricantes, constituindo 6 grupos que foram armazenados em água destilada à 37°C por 24 h. Os conjuntos dente-cimento resinoso cerâmica foram cortados no sentido x e y, produzindo, aproximadamente, 9 corpos de prova (cp) em forma de barra (área adesiva de 0,9 ± 0,1 mm2) por conjunto. Os cp de cada grupo foram divididos aleatoriamente em 4 condições de envelhecimento: armazenagem em água destilada (A) a 37oC por 120 ou 180 dias (d); e termociclagem com 30.000x ou 60.000x (5ºC-55ºC); constituindo 24 grupos (n>12). O teste de micro-tração foi realizado em uma máquina de ensaio universal (1 mm/min). A σ foi calculada e os dados foram analisados estatisticamente através da ANOVA e teste de Tukey (α=0,05). Os grupos RXA-SC 180 d e PF-PA 120 d apresentaram os mais altos valores de σ (32,9 e 29,6 MPa, respectivamente). Os grupos RXA-PA 30.000x (8,9 MPa) e RXU-SC 180 d (8,1 MPa) mostraram os valores mais baixos de σ. O envelhecimento por TC não prejudicou qualquer dos grupos experimentais, mas o envelhecimento por A reduziu significativamente os valores de σ os grupos RXU-SC e PF-PA / Abstract: The aim of this study was to evaluate the bond strength (σ) of resincement systems (RXA- RelyX ARC; RXU- RelyX U100; and PFPanavia F) to dentin and yttria-stabilized zirconia-based ceramic (YZIn- Ceram YZ) after different surface treatments and aging. The occlusal dentin of 72 sound human molars was exposed and conditioned according to the manufacturers' instructions. Ceramic blocks (72) were cut, flattened, sintered, and divided into two groups according to the type of surface treatment: PA- airborne particle abrasion (≤ 45μm alumina particles), and SC- tribochemical silica coating (Rocatec Soft, 3M ESPE). The cementation procedure followed the instructions of each manufacturer, resulting in 6 groups of tooth-cement-ceramic blocks that were stored in 37°C distilled water for 24 h before cutting into nontrimmed bar-shaped specimens (A- adhesive area= 0.9 ± 0.1 mm²). Approximately 9 specimens per block were obtained and they were randomly assigned to one of the 4 aging conditions: 120 or 180 days stored in 37oC distilled water; and thermocycling (5ºC-55ºC) with 30,000 or 60,000 cycles. The experimental design resulted in 24 groups (n>12). The specimens were loaded in tension (F) until failure using a universal testing machine (crosshead speed: 1 mm/min). The σ (F/A) was calculated and data was statistically analyzed using ANOVA and Tukey tests (α=0.05). Groups RXA-SC 180 d and PF-PA 120 d showed the highest σ values (32.9 and 29.6 MPa, respectively). Groups RXA-PA 30,000x (8.9 MPa) and RXU-SC 180 d (8.1 MPa) presented the lowest σ values. Thermocycling did not reduce the σ values of any experimental group, but water storage decreased the σ values for RXU-SC and PF-PA groups / Doutor
|
535 |
Avaliação biológica de materiais protetores do complexo dentino-pulpar /Duque, Cristiane. January 2005 (has links)
Orientador: Josimeri Hebling / Banca: Beatriz Costa / Banca: Carlos Estrela / Banca: Denise Madalena Palomari Spolidorio / Banca: Elisa Maria Aparecida Giro / Resumo: O objetivo deste estudo in vivo foi avaliar a resposta do complexo dentino-pulpar após a aplicação de um cimento de ionômero de vidro modificado por resina, um cimento de hidróxido de cálcio e um extrato de proteínas extraídas da matriz dentinária solúvel em EDTA (ESDP - EDTA-soluble dentin proteins) em cavidades profundas preparadas em dentes de macacos. Dezoito cavidades de classe V profundas foram confeccionadas em pré-molares de quatro macacos-pregos. Nos grupos 1 e 2, as paredes axiais das cavidades foram forradas com ESDP e cimento de ionômero de vidro modificado por resina (Vitrebond - 3M ESPE), respectivamente. No grupo 3 (controle), foi aplicado um cimento de hidróxido de cálcio (Dycal - Dentsply). Em seguida, as cavidades foram restauradas com amálgama. Após seis meses, os animais foram sacrificados e os dentes foram preparados para avaliação microscópica. Cortes seriados de seis micrometros foram corados utilizando as técnicas de H/E, tricrômico de Masson e Brown & Brenn. Nenhuma resposta inflamatória foi observada para os grupos controle ou de materiais experimentais. Entretanto, em relação à deposição de dentina reacional, houve diferença entre os grupos, considerando a seguinte seqüência: ESDP (Grupo 1) > Hidróxido de cálcio (Grupo 3) > Cimento de ionômero de vidro (Grupo 2). Todos os materiais foram biocompatíveis quando aplicados em cavidades profundas. ESDP estimulou maior deposição de matriz de dentina reacional que os cimentos Vitrebond e Dycal. / Doutor
|
536 |
Avaliação "in vitro" da resistência de união de dois sistemas adesivos dentinários à dentina bovina antes e após a termociclagem: teste de cisalhamento e análise estereomicroscópia /Amendola, Alessandra Buhler. January 1999 (has links)
Orientador: José Roberto Rodrigues / Banca: José Claudio Martins Segalla / Banca: Clovis Pagani / Resumo: O objetivo do presente estudo foi o de avaliar e comparar a efetividade da união de dois sistemas adesivos: Scotchbond Multi-Uso Plus (3M) e Etch & Prime 3.0 (Degussa) à dentina bovina antes e após a termociclagem, bem como o de avaliar o tipo de fratura ocorrido na interface dentina/material. Empregaram-se dentes bovinos, que tiveram a superfície vestibular desgastada com lixas de papel de granulação crescente para a exposição da dentina. Os espécimes foram divididos em dois grupos, nos quais aplicou-se os sistemas adesivos e, posteriormente, a resina composta Z100 (3M) por meio de uma matriz de teflon com 4mm de diâmetro. Estes grupos foram subdivididos em dois subgrupos (A e B). O subgrupo A foi submetido ao ensaio mecânico de cisalhamento após 24h e o subgrupo B recebeu a ciclagem térmica, que consistiu de quinhentos ciclos entre 5°C e 55°C, com duração de 30s em cada temperatura, para depois ser submetido ao teste de cisalhamento. O ensaio mecânico foi realizado em máquina lnstron Universal à velocidade de 0,5mm/min. As superfícies fraturadas foram analisadas em estereomicroscópio (Karl Zeiss). A aplicação do teste estatístico ANOVA, ao nível de significância de 0,05, revelou que os valores de resistência de união dos dois sistemas adesivos avaliados não apresentaram diferença estatisticamente significativa e que a utilização da termociclagem não influenciou a resistência adesiva dos materiais testados. O Scotchbond Multi-Uso Plus apresentou predominância de falhas adesivas e o Etch & Prime 3.0 apresentou maior quantidade de fraturas mistas, seguidas pelas fraturas adesivas / Abstract: The aim of fhe present study was to investigate the shear bond strength of two adhesive systems, Scotchbond Multi-Purpose Plus (3M) and Etch & Prime 3.0 (Degussa), to bovine dentin, before and after thermal cycling. Bovine incisors were embedded in self-cured resin and labial dentin surfaces were ground with sequential abrasive sandpapers. The specimens were separated into two groups to receive the adhesive systems. A composite resin cylinder (Z100-3M) was bonded to the dentinal surface. The two groups were divided into two more groups (A and B). The subgroup A was shear tested after 24h and the subgroup B was subjected to 500 thermal cycles, between 5ºC and 55ºC, with a dwell time of 30 seconds and, then, shear tested. The bond strength was performed on a Universal lnstron machine 4301, with a load cell of 500 Kg and a speed of 0,5mm/min. The mode of failure were classified. The analysis of variance (ANOVA), at 5% significant level, revealed that there were no significant differences among the bond strength of the two adhesive systems, and that the thermal cycling did not significantly influence strength of the two materials tested. The Scotchbond Multi-Purpose Plus showed a considerable number of adhesive failures and the Etch & Prime 3.0 showed predominantly mixed fractures, followed by adhesive fractures / Mestre
|
537 |
Discrepâncias de assentamento ocorrido em coroas totais metálicas, com e sem alívio interno, variando-se os términos cervicais e os agentes cimentantes /Figueiredo, Aldari Raimundo January 1997 (has links)
Orientador: Marco Antonio Bottino / Banca: Pedro Tortamano Neto / Banca: Orlando Magalhães Filho / Banca: José Eduardo Junho de Araujo / Banca: Ruy Fonseca Brunetti / Resumo: Foi feita uma análise das discrepâncias de assentamento ocorridas na cimentação de coroas totais metálicas aliviadas ou não, internamente, sobre preparos com término cervical em chanfro; linha zero ou lâmina de faca; plano inclinado em 135°; ombro reto ou degrau em 90° e ombro reto ou degrau em 90°, associado a um bisel em 45°. Empregaram-se quatro tipos de cimentos, sendo três classificados como temporários à base de óxido de zinco e eugenol (Temp Bond e Provy) e outro sem eugenol (Temp Bond NE); e um quarto indicado para cimentações definitivas, cimento de Fosfato de Zinco. Idealizou-se modelos-padrão usinados em aço inoxidável, com características de um preparo para coroa total metálica em um primeiro molar inferior variando-se os términos cervicais conforme estabelecido. Foram obtidas cápsulas metálicas usinadas em aço inoxidável e perfeitamente adaptadas aos modelos-padrão com os términos cervicais correspondentes, nas condições de estarem aliviadas internamente ou não. Empregou-se uma técnica de cimentação padronizada para assentamento destas cápsulas metálicas nos modelos-padrão respectivos. Através de metodologia original promoveu-se a mensuração da discrepância de assentamento nos corpos-de-prova, com o aparelho Metroscópio Horizontal. Concluiu-se que: a) o alívio executado nas superfícies internas das coroas diminui de forma estatisticamente significante a discrepância marginal após a cimentação, independentemente do tipo de cimento empregado e da forma do término cervical adotada; b) o término cervical do preparo no modelo-padrão tipo Lâmina de Faca foi o que apresentou menor discrepância, independente do cimento empregado, seguido pelo Plano Inclinado, Chanfro, Ombro Biselado e Ombro Reto; c) os términos cervicais em Chanfro, Plano Inclinado e Lâmina de Faca, quando analisadas as amostras dos corpos-de-prova com alívio, .... / Abstract: Seating discrepancies during cementation of complete metal crowns internally relieved or not with various finishing lines and cementing agents. This study evaluated the discrepancies during cementation of complete metal crowns either relieved or not on preparation with various margin designs: chamfer, knife edge, 135 degree shoulder, 90 degree shoulder, 90 degree shoulder with 45 degree bevel. Four types of cements, three temporary and one definitive were used: 1- zinc oxide and eugenol temporary cement (Temp Bond); 2- zinc oxide and eugenol temporary cement (Provy); 3- no eugenol temporary cement (Temp Bond NE) and 4- zinc phosphate cement (S.S.White). Machined stainless dies were fabricated to resemble complete crown preparations for a lower first molar with various finishing lines. Machined stainless steel copings, either internally relieved or not were also fabricated to fit the metal dies. A controlled technique was developed to assess seating discrepancies under the horizontal metroscope. Results showed: a) the internally relieved crowns showed after cementation statistically significant reduction of marginal discrepancies regardless of cement type or margin desing; b) knife edge finishing lines showed least dicrepancies regardless of cement type followed by the 135 degree shoulder, chamfer, bevelled 90 degree shoulder and 90 degree shoulder; c) internally relieved copings with chamfer, 135 degree shoulder and knife edge finishing lines showed no statiscally significant marginal discrepancies. This indicates that any of them yields favorable results; d) regarding cements, the least marginal discrepancies were found with Temp Bond NE followed by Temp Bond, Provy and finally by the Zinc Phosphate Cement (S.S.White) / Doutor
|
538 |
Profundidade de polimerização de cimentos resinosos utilizados na cimentação de pinos translúcidos e sua influência sobre a resistência adesiva antes e após ciclagem mecânica /Galhano, Graziela Ávila Prado. January 2008 (has links)
Orientador: Marco Antônio Bottino / Banca: Marco Antônio Bottino / Banca: Mário Alexandre Coelho Sinhoreti / Banca: Roberto Ruggiero Braga / Banca: Claudio Antonio Talge / Banca: Luiz Felipe Valandro / Resumo: Este estudo teve com objetivo analisar a capacidade de um pino translúcido transmitir luz para o interior do canal radicular, bem como analisar o efeito desta polimerização na resistência mecânica e adesiva do conjunto pino, cimento, dente. Além disso, foi avaliada a resistência adesiva de diferentes tipos de cimentos resinosos. Foram utilizados 70 dentes humanos unirradiculares. O canal foi preparado com as fresas n°3 dos sistemas de pinos Light-Post (Bisco Inc, EUA). As raízes foram pintadas com esmalte preto para evitar a passagem de luz pela lateral do dente. Todos os dentes foram tratados com o sistema adesivo All Bond 2 (Bisco) e cimentados com três tipos de cimento formando os seguintes grupos: G1) Cimento Dual Duolink (Bisco) não fotopolimerizado, G2) Cimento Dual duolink fotopolimerizado, G3) Cimento Químico (C&B - Bisco) e G4) cimento fotopolimerizável (Illusion, Bisco). Cada grupo foi subdividido segundo a execução ou não de ciclagem mecânica. Em seguida, os dentes foram cortados perpendicular ao longo eixo do dente obtendo espécimes de 2mm de espessura. Cada secção era correspondente a uma região do dente (cervical, média, apical), possibilitando observar a polimerização do cimento nas diferentes profundidades da raiz realizando a analise Raman em três dentes de cada grupo. Em seguida, foi realizado o teste de push-out.Como resultado foi observado menor grau de conversão em direção apical para os cimentos foto-ativados, enquanto o cimento dual sem foto-ativaçao apresentou maiores valores. Para a resistência adesiva foi observada semelhança estatística inicial entre o cimento Duolink foto-ativado ou não, sendo que q ciclagem mecânica diminui consideravelmente a RA do Duolink quimicamente polimerizado. O cimento fotopolimerizável apresentou valores muito baixos de resistência adesiva e o cimento químico C&B apresentou os maiores valores antes e apos ciclagem mecânica. / Abstract: This study aimed to evaluate the light transmittance of a translucent post in the root canal, as well as the effects of light polymerization onto fatigue resistance and bond strengths at the post/cement/tooth joint. Moreover, the bond strengths obtained with different types of resin cement were determined. 70 human teeth were used. The root canals were prepared with Light Post drills (Bisco Inc, EUA) (size 3). Afterwards, the outer surface of each tooth was covered with black nail varnish to avoid passage of light through the root lateral walls. All teeth were treated with All Bond 2 (Bisco) bonding agent. They were divided into groups according to the resin cement: G1) non light-cured Duo-link dual-cure cement (Bisco), G2) light-cured Duo-link dual-cure cement, G3) C&B chemical-cure cement (Bisco) and G4) Illusion light-cure resin cement (Bisco). Each group was divided into subgroups, to designate the specimens subjected to mechanical cycling or not. Following that, the teeth were sectioned perpendicular to their long axis into 2mm sections. Each section corresponded to one of three study regions (cervical, middle and apical regions of the root canal preparation), allowing the determination of the degree of conversion at different levels of the root by using Raman spectroscopy in three teeth per group. Afterwards, the segments were subjected to Push-out bond strength test. The light-activated cements had the lowest degree of conversion towards the apical region whereas the dual-activated one presented the highest values. As for bond strength, the light- and non light-activated Duo-link groups were statistically similar in the beginning, but the mechanical cycling decreased the bond strength of the non light-activated group. The light-activated cement had the lowest bond strengths and the chemical cement (C&B) presented the highest bond strength values before and after mechanical cycling. / Doutor
|
539 |
Análise comparativa de diferentes materiais utilizados para confecção de restaurações em CAD/CAM /Porto, Thiago Soares. January 2016 (has links)
Orientador: Edson Alves de Campos / Resumo: O objetivo deste estudo é investigar e comparar, por meio de três diferentes protocolos de pesquisa, o comportamento de diferentes materiais cerâmicos utilizados para fabricação de restaurações em CAD/CAM. No Estudo 1, o objetivo foi determinar quais dos materiais possui a melhor usinabilidade, ou seja, a facilidade de corte. Os blocos para CAD/CAM selecionados foram: IPS e.max CAD, IPS Empress CAD, Vitablocs Mark II e LAVA Ultimate, estes cortados em uma máquina de corte (Isomet 4000, Buehler, Lake Bluff, IL, USA) e levados ao microdurômetro. Através das medidas da identação e trincas geradas pela leitura, foi determinado qual dos materiais utilizados em restaurações de CAD/CAM possui a melhor usinabilidade por meio do cálculo do índice de fragilidade. O LAVA Ultimate apresentou a melhor usinabilidade seguido pelo IPS Empress CAD. O IPS e.max CAD e o Vitablocs Mark II não apresentaram diferenças estatisticamente significantes. Para os estudos 2 e 3 os materiais selecionados foram IPS e.max CAD, Vitablocs Mark II, LAVA Ultimate e Enamic. No Estudo 2, o objetivo foi determinar qual dos materiais possui maior resistência à fratura após serem submetidos a diversas condições de termociclagem. Os blocos de cerâmicas de CAD/CAM foram cortados em várias fases até atingirem as dimensões finais de 14mm x 3mm x 2,5mm, no formato de barra, foram confeccionados um total de 144 corpos de prova. A resistência à fratura foi determinada por meio do teste de três pontos com um entalhe realiza... (Resumo completo, clicar acesso eletrônico abaixo) / The aim of this study was to investigate and compare, through three different research protocols, the behavior of different ceramic materials used to manufacture CAD/CAM restorations. In Study 1, the objective was to determine which material has better machinability, i.e., ease of cutting. The blocks for CAD/CAM selected were: IPS e.max CAD IPS Empress CAD, VITABLOCS Mark II and LAVA Ultimate, these were cut on a cutting machine and taken to microhardness. From the measurements of the indentation and crack generated by the readings was determined which of the materials used for CAD/CAM restorations has the better machinability by calculating the Brittleness index. The LAVA Ultimate showed the best machinability followed by IPS Empress CAD. The IPS e.max CAD and VITABLOCS Mark II showed no statistically significant differences. For studies 2 and 3 the selected materials were IPS e.max CAD, VITABLOCS Mark II, LAVA Ultimate and Enamic. In Study 2, the goal was to determine which of the materials have greater fracture toughness after being subjected to various conditions of thermal cycling. Ceramic CAD/CAM blocks were cut in several stages until got the final dimensions of 14mm x 3mm x 2.5mm on bar formats, in total 144 specimens were made. The fracture toughness was determined by the three-point bending test with a notch made in the specimens. Later fractures were analyzed in scanning electron microscope and classified how the fractures occurred. The best performance was shown by the IPS e.max CAD material, where a statistically significant increase was observed after 120,000 cycles term. The LAVA Ultimate and Enamic materials showed reduction in their fracture toughness after thermal cycling. In Study 3, the objective was to determine the best performance among the materials on flexural strength and flexural modulus. The specimens had the same measures of the study 2, but without the notch...(Complete electronic access below) / Doutor
|
540 |
Citotoxidade de cimentos resinosos sobre célular obtidas da polpa de dentes humanos (HDPCs) e odontoblastóides (MDPC-23) /Pontes, Elaine Cristina Voltolini. January 2014 (has links)
Orientador: Carlos Alberto de Souza Costa / Banca: Gelson Luis Adabo / Banca: Adriano Lima / Resumo: O objetivo deste estudo foi avaliar a citotoxicidade de cimentos resinosos quando aplicados sobre cultura de células odontoblastóides (MDPC-23) e pulpares humanas (HDPC). Os seguintes grupos foram formados: G1 - controle (sem tratamento); G2 - Rely X Luting 2; G3 - Rely X U200; G4 - Rely X ARC. Corpos de prova padronizados, preparados com os cimentos, foram imersos em 1 mL de meio de cultura (DMEM) por 24hs para obtenção dos extratos (DMEM + componentes liberados dos cimentos). Após aplicar os extratos sobre as células por 24hs, a viabilidade (MTT assay) e tipo de morte celular (Anexina/PI), bem como a morfologia das células (MEV) foram avaliados. Os dados obtidos foram submetidos à análise estatística de Kruskal-Wallis complementada por Mann-Whitney (α=5%). A análise química dos extratos foi realizada por cromatografia liquida de alta performance (HPLC). Nos grupos G2, G3 e G4, observou-se redução de 95,8%, 31,5% e 22,7% na viabilidade das células MDPC-23, respectivamente. Redução de 89,4% para G2 e aumento em 11,3% e 29% para G3 e G4, respectivamente, foram observados para as HDPCs. Para as células MDPC-23, redução significativa de viabilidade ocorreu em G2 e G3 quando comparado à G1; todavia, para as HDPCs esta redução foi observada apenas em G2 (p<0,05). Para ambas as culturas usadas no estudo, ocorreu 100% de morte celular por necrose apenas em G2, onde o pH do extrato era ácido. Em G3, onde uma pequena quantidade de TEGDMA foi detectado no extrato, houve reduzida morte celular por necrose e discreta alteração morfológica nas células. Todavia, nenhum dano celular ocorreu em G4. De maneira geral, a células MDPC-23 são mais sensíveis do que as HDPCs. Concluiu-se que apenas o cimento Rely X Luting 2 causou intenso efeito citotóxico para ambas culturas de células pulpares usadas neste estudo. Rely X U200 apresentou discreta citotoxicidade, enquanto o cimento Rely X ARC não foi tóxico para as células pulpares... / Abstract: The aim of this study was to evaluate the cytotoxicity of luting cements on cultured MDPC-23 odontoblast-like cells and human dental pulp cells (HDPCs). The following groups were formed: G1 - control (no treatment), G2 - Rely X Luting 2, G3 - Rely X U200; G4 - Rely X ARC. Standard round specimens prepared with resin cements were immersed in 1 ml of culture medium (DMEM) for 24 hours to obtain the extract (DMEM + components released from the cement). After applying the extracts to the cells for 24 hours, the viability (MTT assay) and type of cell death (Annexin/PI) as well as cell morphology (SEM) were evaluated. The data obtained was submitted to Kruskal-Wallis statistical analysis complemented by Mann-Whitney test (α=5%). The chemical analysis of the extracts was performed by high performance liquid chromatography (HPLC). In G2, G3 and G4, there was a reduction of 95.8 %, 31.5 % and 22.7 % in the MDPC-23 cells viability, respectively. A reduction of 89.4 % for G2, as well as an increase of 11.3 % and 29% for G3 and G4 was observed for the HDPCs, respectively. Significant reduction of MDPC-23 viability occurred for G2 and G3 compared to G1. However, for HDPCs this reduction was only observed in G2 (p<0.05). For both cell cultures used in this study, there was 10 % of cell death by necrosis only in G2, in which the pH of the extract was acid. In G3, where a small amount of TEGDMA was detected in the extracts, there was reduced cell death by necrosis and a discrete morphological alteration in cells. No cellular damage occurred in G4. In general, the MDPC-23 cells are more sensitive than HDPCs against the toxicity of resin cement components. It was found that only the Rely X Luting cement caused intense cytotoxic effect for both pulp cell cultures used in this study. Rely X U200 showed mild cytotoxicity, whereas the cement Rely X ARC was not toxic to the pulp cells. / Mestre
|
Page generated in 0.051 seconds